53TP Series IP00 • Three-phase solid-state relay; Ratings 25A, 50A per phase @ 48-530 VAC • 2 package styles IP00 or IP20 (See IP20 spec sheet for more information) • SCR output for heavy industrial loads • Transient protection built in • AC or DC control • Zero-crossing (resistive loads) or random-fire (inductive loads) output • LED input status indicator • UL Recognized, CE Compliant to EN60950-1 PRODUCT SELECTION Control Voltage 90-280 VAC 4-32 VDC 25A 50A A53TP25D D53TP25D A53TP50D D53TP50D AVAILABLE OPTIONS OUTPUT SPECIFICATIONS (1) Description Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk] (2) Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3) Maximum Load Current [Arms] (4) Minimum Load Current [Arms] Maximum Surge Current 50-60 Hz (16.6ms) [Apk] Maximum On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case (Rjc) [°C/W] Maximum I²t for Fusing 50-60 Hz (8.3 msec) [A² sec] Minimum Power Factor (with Maximum Load) 25 A 50 A 48-530 1200 10 500 25 0.05 239/250 1.6 1.02 285/260 0.5 48-530 1200 10 500 50 0.05 597/625 1.6 0.63 1779/1620 0.5 INPUT SPECIFICATIONS (1) Description Control Voltage Range Minimum Turn-On Voltage Minimum Turn-Off Voltage Minimum Input Current (for on-state) Maximum Input Current Nominal Input Impedance Maximum Turn-On Time [msec] (5) Maximum Turn-Off Time [msec] D53 A53 4-32 VDC 4.0 VDC 1.0 VDC 19 mA @ 4V 25 mA @ 32V Current Limiter 1/2 Cycle 1/2 Cycle 90-280 Vrms 90 Vrms 10 Vrms 2.2 mA @ 120V 10mA @ 240V Current Limiter 50 50 GENERAL SPECIFICATIONS Description Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 V DC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Encapsulation Terminals Screws and Saddle clamps Input Terminal Screw Torque Range:[in lbs/Nm] Output Terminal Screw Torque Range:[in lbs/Nm] GENERAL NOTES 1) All parameters at 25°C unless otherwise specified. 2) Relay will self trigger between 900-1200 Vpk. 3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 4) Heat sinking required, see page 4 for derating curves. 5) Turn-on time for Random turn-on versions is 0.02 msec (DC Control Models) Parameters 4000 Vrms 109 Ohm 8 pF -40 to 80°C -40 to 125 °C 10.3 oz (315g) Thermally conductive Epoxy Nickel plated Brass Zinc plated Steel 8-10 / 0.9-1.1 15-20 / 1.7-2.2 MECHANICAL SPECIFICATIONS WIRING DIAGRAM THERMAL DERATE INFORMATION AGENCY APPROVALS Input : EN61000-4-2, Level 3 ESD EN61000-4-4, Level 3 Burst Output : EN61000-4-2, Level 4 ESD EN61000-4-4, Level 4 Burst EN61000-4-5, Level 4 Surge EN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: Rev. 120811 ANNEX - ENVIROMENTAL INFORMATION