SERIES: ETSA 60W-U │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
up to 60 W power
universal input (90~264 Vac)
compact size
single regulated output from 12~24 V
over voltage and short circuit protections
UL/cUL, Intertek and PSE safety approvals
level V efficiency
custom designs available
RoHS
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
ETSA120500U
12
5
60
200
ETSA190342U
19
3.42
60
240
V
ETSA240270U
24
2.7
60
240
V
MODEL
Notes:
efficiency
level
1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 μF aluminum electrolytic and 0.1 μF ceramic capacitors.
PART NUMBER KEY
ETSA120500U C - XX - SZ - CXX
DC Plug Type
Base Number
Reserved for Custom
Configurations
example of 12 Vdc, 5 A
Input Cable:
C = Included
Blank = No Cable
Factory
Designation
cui.com
V
CUI Inc │ SERIES: ETSA 60W-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/14/2012 │ page 2 of 6
INPUT
parameter
conditions/description
min
voltage
typ
90
frequency
47
max
units
264
Vac
63
Hz
current
12 V output
all other outputs
1.4
1.5
A
A
no load power consumption
12 V output
all other outputs
0.3
0.5
W
W
max
units
OUTPUT
parameter
conditions/description
min
typ
line regulation
±1
%
load regulation
±5
%
PROTECTIONS
parameter
conditions/description
over voltage protection
output voltage clamped by internal protection
zener
short circuit protection
output shut down, auto restart
SAFETY & COMPLIANCE
parameter
conditions/description
min
isolation voltage
input to output at 10 mA for 1 minute
insulation resistance
input to output at 500 Vdc
typ
max
units
1,500
Vac
100
MΩ
safety approvals
UL/cUL (UL 60950-1), EN 60950-1/IEC 60950-1, PSE
EMI/EMC
FCC part 15, subpart b, class B; CE; CISPR 22, class B; ICES-003; ANSI C63.4; EN 61204-3; EN
55022; EN 55024; EN 61000-(2, 3); IEC 61000-4-(2, 3, 4, 5, 6, 8, 11)
leakage current
12 V output
all other outputs
RoHS compliant
yes
0.35
0.25
mA
mA
max
units
0
40
°C
storage temperature
-10
70
°C
operating humidity
20
80
%
storage humidity
10
90
%
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
cui.com
typ
CUI Inc │ SERIES: ETSA 60W-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/14/2012 │ page 3 of 6
MECHANICAL
parameter
conditions/description
dimensions
4.488 x 1.850 x 1.276 (114 x 47 x 32.4 mm)
weight
Notes:
min
typ
1. weight does not include AC Cord
MECHANICAL DRAWING
units: mm
cui.com
units
inch
230
1
max
g
CUI Inc │ SERIES: ETSA 60W-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/14/2012 │ page 4 of 6
DC CORD
21±3
cord length
2.8~4.0mm
S&T
95±10
48B
MODEL NO.
CABLE GAUGE
CORD LENGTH
ETSA120500U
16 AWG
1,000 mm ±100
ETSA190342U
18 AWG
1,530 mm ±100
ETSA240270U
18 AWG
1,530 mm ±100
1.5±0.1000
+200
+30
14±0.2
+0.5
5 0
+0.5
2.5 0
17±1
6.05 min.
17.75 max.
6.3±0.05
1830
12.7±0.13
ø4
.7
5±
0.
05
11.9±0.1
10.8 min.
14.6 max.
AC CORD
21.4 max.
+0
130 -30
PE
UL SVT 18AWGX3C VW-1
YP-12/YC-12
cui.com
4±0.1
CUI Inc │ SERIES: ETSA 60W-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/14/2012 │ page 5 of 6
OUTPUT PLUG OPTIONS
ø3.5 +0/-0.1
ø3.5 +0/-0.1
3.5 mm Phono Plug
14±0.5
14±0.5
*Tip positive
P1
P1R
Standard DC Plug
Standard PX
B
A
B
A
A
B
C
Unit
P5/P5R
5.5
2.1
9.5
mm
P6/P6R
5.5
2.5
9.5
mm
P7/P7R
3.5
1.35
9.5
mm
P8/P8R
3.8
1.35
9.5
mm
P9/P9R
3.8
1.05
9.5
mm
A
B
C
Unit
P10
5.5
2.1
9.5
mm
P11
5.5
2.5
9.5
mm
C
C
Right Angle PXR
Locking DC Plug
B
A
C
EIAJ Plugs
B
A
B
A
C
EIAJ
A
B
C
D
Unit
P12/P12R
EIAJ-1
2.35
0.7
9.5
NA
mm
P13/P13R
EIAJ-2
4.0
1.7
9.5
5.0
mm
P14/P14R
EIAJ-3
4.75
1.7
9.5
5.0
mm
C
Standard PXX
Right Angle PXXR
D
Stripped and Tinned
25±5
9±2
DC PLUG TYPE
ST
Stripped and Tinned
PXX X X
Plug Type
Plug Angle:
“Blank” = Standard
R = Right Angle
Plug Polarity:
“Blank” = N/A
P = Center Positive
N = Center Negative
*Contact CUI for additional output plug options.
cui.com
CUI Inc │ SERIES: ETSA 60W-U │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/14/2012 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
12/05/2011
1.01
updated P7/P7R B dimension, V-Infinity branding removed, safety and
EMI/EMC data updated
08/15/2012
updated DC Cord information
11/14/2012
1.02
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.