date 11/14/2012 page p g 1 of 6 SERIES: ETSA 60W-U │ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • • • • • • • • up to 60 W power universal input (90~264 Vac) compact size single regulated output from 12~24 V over voltage and short circuit protections UL/cUL, Intertek and PSE safety approvals level V efficiency custom designs available RoHS output voltage output current output power ripple and noise1 (Vdc) max (A) max (W) max (mVp-p) ETSA120500U 12 5 60 200 ETSA190342U 19 3.42 60 240 V ETSA240270U 24 2.7 60 240 V MODEL Notes: efficiency level 1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 μF aluminum electrolytic and 0.1 μF ceramic capacitors. PART NUMBER KEY ETSA120500U C - XX - SZ - CXX DC Plug Type Base Number Reserved for Custom Configurations example of 12 Vdc, 5 A Input Cable: C = Included Blank = No Cable Factory Designation cui.com V CUI Inc │ SERIES: ETSA 60W-U │ DESCRIPTION: AC-DC POWER SUPPLY date 11/14/2012 │ page 2 of 6 INPUT parameter conditions/description min voltage typ 90 frequency 47 max units 264 Vac 63 Hz current 12 V output all other outputs 1.4 1.5 A A no load power consumption 12 V output all other outputs 0.3 0.5 W W max units OUTPUT parameter conditions/description min typ line regulation ±1 % load regulation ±5 % PROTECTIONS parameter conditions/description over voltage protection output voltage clamped by internal protection zener short circuit protection output shut down, auto restart SAFETY & COMPLIANCE parameter conditions/description min isolation voltage input to output at 10 mA for 1 minute insulation resistance input to output at 500 Vdc typ max units 1,500 Vac 100 MΩ safety approvals UL/cUL (UL 60950-1), EN 60950-1/IEC 60950-1, PSE EMI/EMC FCC part 15, subpart b, class B; CE; CISPR 22, class B; ICES-003; ANSI C63.4; EN 61204-3; EN 55022; EN 55024; EN 61000-(2, 3); IEC 61000-4-(2, 3, 4, 5, 6, 8, 11) leakage current 12 V output all other outputs RoHS compliant yes 0.35 0.25 mA mA max units 0 40 °C storage temperature -10 70 °C operating humidity 20 80 % storage humidity 10 90 % ENVIRONMENTAL parameter conditions/description min operating temperature cui.com typ CUI Inc │ SERIES: ETSA 60W-U │ DESCRIPTION: AC-DC POWER SUPPLY date 11/14/2012 │ page 3 of 6 MECHANICAL parameter conditions/description dimensions 4.488 x 1.850 x 1.276 (114 x 47 x 32.4 mm) weight Notes: min typ 1. weight does not include AC Cord MECHANICAL DRAWING units: mm cui.com units inch 230 1 max g CUI Inc │ SERIES: ETSA 60W-U │ DESCRIPTION: AC-DC POWER SUPPLY date 11/14/2012 │ page 4 of 6 DC CORD 21±3 cord length 2.8~4.0mm S&T 95±10 48B MODEL NO. CABLE GAUGE CORD LENGTH ETSA120500U 16 AWG 1,000 mm ±100 ETSA190342U 18 AWG 1,530 mm ±100 ETSA240270U 18 AWG 1,530 mm ±100 1.5±0.1000 +200 +30 14±0.2 +0.5 5 0 +0.5 2.5 0 17±1 6.05 min. 17.75 max. 6.3±0.05 1830 12.7±0.13 ø4 .7 5± 0. 05 11.9±0.1 10.8 min. 14.6 max. AC CORD 21.4 max. +0 130 -30 PE UL SVT 18AWGX3C VW-1 YP-12/YC-12 cui.com 4±0.1 CUI Inc │ SERIES: ETSA 60W-U │ DESCRIPTION: AC-DC POWER SUPPLY date 11/14/2012 │ page 5 of 6 OUTPUT PLUG OPTIONS ø3.5 +0/-0.1 ø3.5 +0/-0.1 3.5 mm Phono Plug 14±0.5 14±0.5 *Tip positive P1 P1R Standard DC Plug Standard PX B A B A A B C Unit P5/P5R 5.5 2.1 9.5 mm P6/P6R 5.5 2.5 9.5 mm P7/P7R 3.5 1.35 9.5 mm P8/P8R 3.8 1.35 9.5 mm P9/P9R 3.8 1.05 9.5 mm A B C Unit P10 5.5 2.1 9.5 mm P11 5.5 2.5 9.5 mm C C Right Angle PXR Locking DC Plug B A C EIAJ Plugs B A B A C EIAJ A B C D Unit P12/P12R EIAJ-1 2.35 0.7 9.5 NA mm P13/P13R EIAJ-2 4.0 1.7 9.5 5.0 mm P14/P14R EIAJ-3 4.75 1.7 9.5 5.0 mm C Standard PXX Right Angle PXXR D Stripped and Tinned 25±5 9±2 DC PLUG TYPE ST Stripped and Tinned PXX X X Plug Type Plug Angle: “Blank” = Standard R = Right Angle Plug Polarity: “Blank” = N/A P = Center Positive N = Center Negative *Contact CUI for additional output plug options. cui.com CUI Inc │ SERIES: ETSA 60W-U │ DESCRIPTION: AC-DC POWER SUPPLY date 11/14/2012 │ page 6 of 6 REVISION HISTORY rev. description date 1.0 initial release 12/05/2011 1.01 updated P7/P7R B dimension, V-Infinity branding removed, safety and EMI/EMC data updated 08/15/2012 updated DC Cord information 11/14/2012 1.02 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.