DELTA DS04S0303A

DS06S/D Series
6W DC/DC CONVERTER, DIP-Package, 4:1 Wide Input Range
FEATURES

Efficiency up to 83%

DIP Package with Industry Standard Pinout

Short Circuit Protection

Isolation Voltage1500VDC

Operating Temperature Range –40°C to +85°C

Wide 4:1 Input Range

Complies with EN55022 Class A

Lead free, RoHs Complian

3 Years Product Warranty
The DS06S/D series are miniature, DIP Package, isolated 6W DC/DC converters with 1,500VDC isolation. It offers short circuit
protection and allows a wide operating temperature range of –40°C to +85°C. These isolated DC/DC converters are the latest offering
from a world leader in power systems technology and manufacturing ― Delta Electronics, Inc. With creative design technology and
optimization of component placement, these converters possess outstanding electrical and thermal performance, as well as extremely
high reliability under highly stressful operating conditions
Model List
Model
Number
DS06S2403A
DS06S2405A
DS06S2412A
DS06S2415A
DS06D2405A
DS06D2412A
DS06D2415A
DS06S4803A
DS06S4805A
DS06S4812A
DS06S4815A
DS06D4805A
DS06D4812A
DS06D4815A
Input
Voltage
(Range)
Output
Voltage
VDC
VDC
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
24
(9 ~ 36)
48
(18 ~ 75.)
Output
Current
Input Current
Max.
Min.
@Max. Load
@No Load
Reflected
Ripple
Current
mA
1200
1000
500
400
±500
±250
±200
1200
1000
500
400
±500
±250
±200
mA
120
100
50
40
±50
±25
±20
120
100
50
40
±50
±25
±20
mA(typ.)
220
267
301
305
267
301
305
110
134
151
152
134
151
152
mA(typ.)
mA(typ.)
Max. capacitive
Load
uF
@Max. Load
470
20
20
100
100*
470
10
15
Efficiency
(typ.)
100
100*
%
75
78
83
82
78
83
82
75
78
83
82
78
83
82
* For each output
Input Characteristics
Parameter
Input Surge Voltage (1 sec. max.)
Start-Up Voltage
Under Voltage Shutdown
Reverse Polarity Input Current
Short Circuit Input Power
Internal Power Dissipation
Conducted EMI
DS_DS06S/D_06102013
Model
24V Input Models
48V Input Models
24V Input Models
48V Input Models
24V Input Models
48V Input Models
All Models
Min.
-0.7
-0.7
7
14
-----------
Typ.
----8
16
-----------
Max.
50
100
9
18
8.5
16
1
3000
2500
Unit
VDC
A
mW
mW
Compliance to EN 55022,class A and FCC part 15,class A
E-mail: [email protected]
http://www.delta.com.tw/dcdc
P1
Output Characteristics
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Conditions
Dual Output, Balanced Loads
Vin=Min. to Max.
Io=10% to 100%
Asymmetrical load 25% / 100%
FL
Cross Regulation (Dual)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Short Circuit Protection
Min.
---------
Typ.
±1.0
±1.0
±0.1
±0.5
Max.
±2.0
±2.0
±0.5
±1.0
Unit
%
%
%
%
---
---
±5.0
%
80
100
15
500
--±0.02
350
mV P-P
mV P-P
mV rms
uS
%
%/℃
%
------------110
Over Line, Load & Temp.
25% Load Step Change
Foldback
50
----300
±3
±0.01
250
Continuous
General Characteristics
Parameter
I/O Isolation Voltage (rated)
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
1500
---
---
VDC
I/O Isolation Resistance
500 VDC
1000
---
---
MΩ
I/O Isolation Capacitance
100KHz, 1V
---
1000
1200
pF
---
450
---
KHz
800,000
---
---
Hours
Switching Frequency
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
Safety Approvals
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1
Recommended Input Fuse
24V Input Models
48V Input Models
1200mA Slow-Blow Type
750mA Slow-Blow Type
Environmental Characteristics
Parameter
Conditions
Min.
Max.
Unit
Ambient
-40
+85
℃
Case Temperature
---
+100
℃
Storage Temperature Range
-50
+125
℃
Humidity (non condensing)
---
95
% rel. H
260
℃
Operating Temperature Range (with
Derating)
Cooling
Free-Air convection
Lead Temperature (1.5mm from case for
10Sec.)
---
Power Derating Curve
100
Natural
convection
Output Power (%)
80
100LFM
200LFM
60
400LFM
40
20
0
~
-40
0
20
40
60
80
100 110
Ambient Temperature
DS_DS06S/D_06102013
E-mail: [email protected]
http://www.delta.com.tw/dcdc
P2
Notes
1
2
3
4
5
6
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%
Ripple & Noise measurement bandwidth is 0-20MHz.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not
damage these modules; however they may not meet all specifications listed.
All DC/DC converters should be externally fused at the front end for protection.
Specifications subject to change without notice.
Mechancial Drawing
4.1
[0.16]
10.2
[0.40]
Mechanical Dimensions
0.50 [0.02]
Bottom View
23
22
16
15.24 [0.60]
2.54
[0.10]
31.8 [1.25]
Dual Output
-Vin
3
-Vin
-Vin
9
No Pin
Common
11
NC
-Vout
14
+Vout
+Vout
16
-Vout
Common
22
+Vin
+Vin
23
+Vin
+Vin
11
20.3 [0.80]
9
15.22 [0.60]
3
NC: No Connection
14
5.08 4.5
[0.20][0.18]
2.54
[0.10]
2
Pin Connections
Pin
Single Output
2
-Vin
►All dimensions in mm (inches)
►Tolerance: X.X±0.25 (X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►Pin diameter  0.5 ±0.05 (0.02±0.002)
Physical Outline
ase Size
:
31.8x20.3x10.2mm (1.25x0.80x0.40 Inches)
Case Material
:
Aluminum Anodizing Treatment in Black
Weight
:
13.9g
DS_DS06S/D_06102013
E-mail: [email protected]
http://www.delta.com.tw/dcdc
P3
Part Numbering System
D
S
06
S
24
05
A
Form factor
Family series
Watt
Number of
Outputs
Input Voltage
Output Voltage
Option Code
D-DIP
P-SIP
S-SMD
A~Z
01:1W
02:2W
03:3W
04:4W
06:6W
03:3.3V
05: 5V
12:12V
24: 24V
48:48V
03:3.3V
05: 5V
12:12V
15: 15V
24: 24V
A - Std. Functions
S - Single
D- Dual
WARRANTY
Delta offers a three(3) years limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any
infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under
any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice.
DS_DS06S/D_06102013
E-mail: [email protected]
http://www.delta.com.tw/dcdc
P4