EMERSON-NETWORKPOWER 127-0701-201

Connectivity for
Business-Critical Continuity
Type SMP Connectors
Product Catalog
Connectivity for
Business-Critical Continuity
SMP Connectors
Table of Content
Table of Contents
PAGE
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-8
Mounting Holes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-12
Assembly Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Assembly Instructions . . . . . . . . . . . . . . . . . . . . . . . . . .14-18
Competitor Cross Reference . . . . . . . . . . . . . . . . . . . . . . .19
2
Connectivity for
Business-Critical Continuity
SMP Connectors
Introduction
SMP Blind-Mate Connectors
Emerson’s new Johnson® line of SMP Blind-Mate Connectors offers our customers a Micro-Miniature,
Slide-On/Snap-On Interconnect System that aid’s in the design ofhigh-density packaging as well as axial and
radial misalignment issues.
The SMP Interface offers superior performance up to 40 GHz and is compatible with all SMP and GPO®
Connectors. They offer high electrical reliability where extreme shock and vibration condition’s are experienced.
Applications (Military and Commercial)
• Phased Arrays
• Active Antennas
• Satellites
• Communication
Equipment
• Airborne Radar
•Shipborne Radar
•Ground Radar
• Hi-Density Modular
Packaging
• Axial/ Radial
Misalignment
Solutions
• Aerospace
• Broadband
• Instrumentation
• Telecom
• Defense
• Microwave
Markets
Transmission Options
•
•
•
•
Box-to-Box
Cable-to-Board
Board-to-Board
Cable-to-Panel-to-Board
*GPO® is a registered trademark of Corning Gilbert.
3
Connectivity for
Business-Critical Continuity
SMP Connectors
Introduction
Description
One of the key benefits of the SMP connector interface is its use in high frequency blind-mate applications. The
design of the SMP bullet and shroud system allows for both axial and radial misalignment. The basic system is
comprised of an inner “bullet” adapter, and two outer receptacles called “shrouds”. The bullet provides a
flexible link between the shroud connections.
In blind-mate applications, one shroud connector will be typically specified as a snap-on interface and the other
as a slide-on. This ensures that the bullet adapter remains fixed in the same shroud connector when the
connection is disengaged.
The two snap-on interfaces Full Detent (FD) and Limited Detent (LD) each have different engage and disengage
coupling forces. The LD is typically selected as the snap-on interface in PCB mount or blind-mate applications,
while the FD is mainly used for cabled connections where higher retention forces are required.
The two slide-on interfaces Smooth Bore (SM) and Catcher’s Mit (CM) allow for reduced connection forces as
compared to the snap-on versions. The push-on interface creates a sliding connection that does not physically
locate the mating reference planes, allowing for axial and radial misalignment. Both the SM and CM have the
same engage/disengage forces; however the CM is typically specified as the shroud configuration in blind-mate
applications as its generous lead-in chamfer helps capture and guide the bullet into place.
Radial Misalignment
Axial Misalignment
Bullet Length
Shroud
4
Connectivity for
Business-Critical Continuity
SMP Connectors
Specifications
ELECTRICAL SPECIFICATIONS
Impedance: 50 Ohms
Frequency Range:
Bullet Adapter (.254 length), Semi-Rigid Straight Cabled Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-40 GHz
All other In-Series Adapters, Semi-Rigid Right Angle Cabled Connectors,
Field Replaceable Connectors, End Launch Connectors, Hermetic Feedthroughs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-18 GHz
PC Mount Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-12 GHz
VSWR: (maximum)
0-18 GHz 18-23 GHz
Bullet Adapter (.254 length) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.10
1.15
0-18 GHz
Semi-Rigid Straight Cabled Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
0-4 GHz
All other In-Series Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.10
23-26.5 GHz
1.30
18-26.5 GHz
1.35
4-12 GHz
1.15
26.5-40 GHz
1.70
26.5-40 GH
1.70
12-18 GHz
1.20
0-18 GHz
Semi-Rigid Right Angle Cabled Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.20
0-18 GHz
Field Replaceable Connectors (typical, measured back to back with seal pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.15
Un-cabled Connectors (dependant on application) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not Applicable
Insertion Loss: (dB maximum, tested at 10 GHz)
In-Series Adapters, Field Replaceable Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.10 √ F (GHz)
Semi-Rigid Cabled Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.12 √ F (GHz)
All other Un-cabled Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not Applicable
Working Voltage: 335 Vrms maximum at sea level, 65 Vrms maximum at 70,000 feet
Dielectric Withstanding: Voltage: 500 Vrms minimum at sea level
RF High Potential Withstanding Voltage: 325 Vrms minimum at sea level, tested at 4 and 7 MHz
Corona Level: 190 Vrms minimum at 70,000 feet
Contact Resistance: (milliohms maximum initial, not applicable after environmental testing)
Center Contact (Connectors and Adapters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.0
Outer Contact (Connectors and Adapters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.0
Cable Shield to Body (Semi-Rigid Cabled Connectors Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5
Insulation Resistance: 5000 megohms minimum
RF Leakage: (dB typical, tested at 2.5 GHz)
Cabled and Field Replaceable Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -80
In-Series Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65
All other Un-cabled Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not Applicable
5
Connectivity for
Business-Critical Continuity
SMP Connectors
Specifications
MECHANICAL SPECIFICATIONS
Interface Design: MIL-STD-348A, Series SMP
Engagement Force: (pounds maximum, mated pair)
Full Detent (FD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.0
Limited Detent (LD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.0
Smooth Bore and Catcher’s Mit (SM and CM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.0
Disengagement Force: (pounds minimum, mated pair)
Full Detent (FD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.0
Limited Detent (LD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.0
Smooth Bore and Catcher’s Mit (SM and CM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5
Mated Radial Misalignment: (inches maximum allowed, female adapters only)
Between Centerlines of Mating Planes (FD, LD, SM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .010
Between Centerlines of Mating Planes (CM only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .020
Mated Axial Misalignment: .010 inches maximum allowed between mating planes (female adapters only)
Durability: (mating cycles minimum)
Full Detent (all female connectors and adapters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Limited Detent (female adapters only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
Smooth Bore and Catcher’s Mit (female adapters only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000
Contact Retention: 1.5 pounds minimum axial force (captivated contacts only)
Cable Retention: (minimum)
Axial Force* (lbs)
Cabled Connectors for RG-405 (.086 Semi-Rigid) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Cabled Connectors for M17/151 (.047 Semi-Rigid) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Torque (in-oz)
16.0
N/A
*Or cable breaking strength, whichever is less
Typical Measured Return Loss
Bullet Adapter 127-0901-801
127-0801-901
VSWR = 1.10 (0-18 GHz), 1.15 (18-23 GHz), 1.30 (23-26.5 GHz), 1.70 (26.5-40 GHz)
0
-10
S11 (dB)
-20
-30
-40
-50
-60
0
5
10
15
20
Frequency (GHz)
6
25
30
35
40
Connectivity for
Business-Critical Continuity
SMP Connectors
Specifications
ENVIRONMENTAL SPECIFICATIONS
(Meets or Exceeds the Applicable Paragraph of MIL-PRF-39012)
Operating Temperature: -65°C to +165°C
Thermal Shock: MIL-STD-202, Method 107, Condition B (except high temp +165°C or max high temp of cable)
Corrosion: MIL-STD-202, Method 101, Condition B
Shock (specified pulse): MIL-STD-202, Method 213, Condition I
Vibration: MIL-STD-202, Method 204, Condition D
Moisture Resistance: MIL-STD-202, Method 106 (except step 7b omitted)
MATERIAL SPECIFICATIONS
Spring Finger (female) and End Launch (male) Bodies: Beryllium Copper per ASTM B196,
Gold* plated per MIL-DTL-45204 (.00005” min)
Hermetic Seal Bodies (male): Kovar Alloy per ASTM F15, Gold* plated per MIL-DTL-45204 (.00005” min)
All other Shroud Bodies (male): Stainless Steel, Type 303, per ASTM A582, Passivated per MIL-DTL-14072 (EL 300)
Connector and Adapter Contacts (male and female): Beryllium Copper per ASTM B196,
Gold* plated per MIL-DTL-45204 (.00005” min)
Hermetic Seal Center Pins: Kovar Alloy per ASTM F15, Gold* plated per MIL-DTL-45204 (.00005” min)
EMI/Anti-Rock Rings: Beryllium Copper per ASTM B196, Gold* plated per MIL-DTL-45204 (.00003” min)
PC Mount Legs: Brass per ASTM B16, Gold* plated per MIL-DTL-45204 (.00003” min)
Connector and Adapter Insulators: PTFE per ASTM D1710
Hermetic Seal Glass: Corning 7070
*All gold plated parts include a .00005” min nickel barrier layer.
MOUNTING HOLES
Fig 1
Fig 2
Fig 3
This pattern is for reference only.
Pattern will vary depending on board
type and specific electrical and
mechanical requirements.
7
Connectivity for
Business-Critical Continuity
SMP Connectors
Specifications
Mating Engagement for SMP Series per MIL-STD-348A
Notes:
1. Socket to accept mating pin Ø.015±.001 (0.38±0.03).
2. EMI/Anti-Rock Ring configuration optional, used on cabled connectors only. Shall not prevent proper mating engagement.
3. All dimensions shown in inches. Metric equivalents (rounded to nearest 0.01mm) are given for general information only.
SMP Female Connector Interface
Dimension
A
Cabled
Uncabled
Minimum
Maximum
Minimum
Maximum
.025 (0.64)
.035 (0.89)
.018 (0.46)
.025 (0.64)
SMP Male Connector Interface
Dimension
B
C
D
E
F
G
H
K
M
8
Full Detent
Minimum
Maximum
Limited Detent
Minimum
Maximum
Smooth Bore
Minimum
Maximum
Catcher’s Mit
Minimum
Maximum
.051 (1.30)
.0205 (0.52)
.003 (0.08)
.033 (0.84)
.139 (3.53)
.114 (2.90)
.124 (3.15)
35° REF
30° REF
.054 (1.37)
.0205 (0.52)
.003 (0.08)
.033 (0.84)
.139 (3.53)
.118 (3.00)
.124 (3.15)
35° REF
30° REF
.059 (1.50)
N/A
.003 (0.08)
.033 (0.84)
.139 (3.53)
.123 (3.12)
N/A
35° REF
N/A
N/A
N/A
.043 (1.09)
N/A
.123 (3.12)
N/A
N/A
N/A
N/A
.057 (1.45)
.0235 (0.60)
.008 (0.20)
.037 (0.94)
.145 (3.68)
.118 (3.00)
.126 (3.20)
35° REF
30° REF
.060 (1.52)
.0235 (0.60)
.008 (0.20)
.037 (0.94)
.145 (3.68)
.122 (3.10)
.126 (3.20)
35° REF
30° REF
.065 (1.65)
N/A
.008 (0.20)
.037 (0.94)
.145 (3.68)
.127 (3.23)
N/A
35° REF
N/A
N/A
N/A
.047 (1.19)
N/A
.127 (3.23)
N/A
N/A
N/A
N/A
Connectivity for
Business-Critical Continuity
SMP Connectors
Application
Straight Solder Type Cabled Female
Fig 1
Cable Type
VSWR & Freq. Range*
M17/151, .047 Semi-Rigid 1.20 Max 0-18 GHz,
1.35 Max 18-26.5 GHz,
1.70 Max 26.5-40 GHz
RG-405, .086 Semi-Rigid 1.20 Max 0-18 GHz,
1.35 Max 18-26.5 GHz,
1.70 Max 26.5-40 GHz
Gold Plated
Figure
127-0692-001
1
127-0693-001
2
Fig 2
* Specifications dependant on cable ratings
Right Angle Solder Type Cabled Female
Cable Type
VSWR & Freq. Range Gold Plated “A”
M17/151, .047 Semi-Rigid 1.20 Max 0-18 GHz
RG-405, .086 Semi-Rigid 1.20 Max 0-18 GHz
“B”
127-0692-101 .248 (6.30) .197 (5.00)
127-0693-101 .271 (6.88) .209 (5.31)
Straight PC Mount Male Receptacle
Interface
Freq. Range
Passivated*
“A”
Full Detent
Limited Detent
Smooth Bore
Catcher’s Mit
0-12 GHz
0-12 GHz
0-12 GHz
0-12 GHz
127-0701-201
127-1701-201
127-2701-201
127-3701-201
.218 (5.54)
.218 (5.54)
.218 (5.54)
.234 (5.94)
* Base and legs Gold plated brass
Mounting hole layout figure 3 on page 7.
9
Connectivity for
Business-Critical Continuity
SMP Connectors
Application
End Launch Male Receptacle – Surface Mount
Interface
Freq. Range Gold Plated
Packaging
Full Detent
Full Detent
Limited Detent
Limited Detent
Smooth Bore
Smooth Bore
0-18 GHz
0-18 GHz
0-18 GHz
0-18 GHz
0-18 GHz
0-18 GHz
Stock
Tape and Reel -1000 pieces
Stock
Tape and Reel -1000 pieces
Stock
Tape and Reel -1000 pieces
127-0701-801
127-0701-802
127-1701-801
127-1701-802
127-2701-801
127-2701-802
Mounting hole layout figure 1 on page 7.
2-Hole Flange Mount Male Shroud - Without Contact
Interface
Passivated
Full Detent
Limited Detent
Smooth Bore
127-0701-602
127-1701-602
127-2701-602
2-Hole Flange Mount Male Catcher’s Mit Shroud - Without Contact
Interface
Passivated
Catcher’s Mit
127-3701-602
10
Connectivity for
Business-Critical Continuity
SMP Connectors
Application
2-Hole Flange Mount Male Field Replaceable
Interface
VSWR & Freq. Range*
Passivated
Accepts Pin Size
Full Detent
Limited Detent
Smooth Bore
1.15 Typical 0-18 GHz
1.15 Typical 0-18 GHz
1.15 Typical 0-18 GHz
127-0701-612
127-1701-612
127-2701-612
.012 (.030)
.012 (.030)
.012 (.030)
* Two connectors mated back to back with hermetic seal fixture
Hermetic Seal Male
Interface
Freq. Range
Gold Plated
Full Detent
Limited Detent
Smooth Bore
0-18 GHz
0-18 GHz
0-18 GHz
127-0711-601
127-1711-601
127-2711-601
Mounting hole layout figure 2 on page 7.
Female to Female Bullet Adapter
VSWR & Freq. Range Gold Plated
1.10 Max 0-18 GHz,
1.15 Max 18-23 GHz,
1.30 Max 23-26.5 GHz,
1.70 Max 26.5-40 GHz
127-0901-801
11
Connectivity for
Business-Critical Continuity
SMP Connectors
Application
Female to Female Adapter
VSWR & Freq. Range Gold Plated
1.10 Max 0-4 GHz,
1.15 Max 4-12 GHz,
1.20 Max 12-18 GHz
127-0901-811
Male to Male Catcher’s Mit Adapter
Interface
VSWR & Freq. Range
Passivated
Full Detent
1.10 Max 0-4 GHz,
1.15 Max 4-12 GHz,
1.20 Max 12-18 GHz
1.10 Max 0-4 GHz,
1.15 Max 4-12 GHz,
1.20 Max 12-18 GHz
1.10 Max 0-4 GHz,
1.15 Max 4-12 GHz,
1.20 Max 12-18 GHz
127-0901-821
Limited Detent
Smooth Bore
12
127-1901-821
127-2901-821
Connectivity for
Business-Critical Continuity
SMP Connectors
Assembly Tools
SMP Customer Tooling
Accurate assembly of the Semi-Rigid Cabled Connectors is obtained with the tools listed below. Industry standard devices are used if possible for
customer convenience and tool compatibility.
E.
C.
F.
B.
G.
D.
H.
A.
I.
Item
Description
Part Number
A
B
C
D
E
SMP Bullet Extraction Tool
SMP Cabled Connector Removal Tool
Soldering Vise (does not include clamp inserts or stop screw)
Stop Screw for Soldering Vise
Semi-Rigid Cable Clamp Inserts for .086" OD Cable
Semi-Rigid Cable Clamp Inserts for .047" OD Cable
Solder Shim for .086" OD Cable
SMP Center Contact Holder
SMP Interface Locator Tool
SMP Right Angle Body Holder
SMP FD Shroud Centering Tool
SMP LD Shroud Centering Tool
SMP SB Shroud Centering Tool
127-0000-900
127-0000-901
140-0000-962
140-0000-981
140-0000-964
140-0000-997
140-0000-984
127-0000-902
127-0000-903
127-0000-904
127-0000-905
127-0000-906
127-0000-907
F
G
H
I
J
J.
13
Connectivity for
Business-Critical Continuity
SMP Connectors
Assembly Instructions
ASSEMBLY INSTRUCTIONS
SMP Straight Female Solder Style for .047 OD Semi-Rigid Cable
1 Identify tools (5 piece parts) and connector parts (3 piece parts).
2. Strip cable jacket and dielectric to dimension shown. Do not
nick center conductor. Clean all debris from prepared cable.
3. Insert center conductor into cable stop as shown and place
contact onto center conductor.
4. Insert contact into contact holder fixture and clamp cable in vise.
Tighten stop screw until light pressure is applied between contact, cable stop and cable jacket.
5. Solder contact to center conductor through solder hole using
.016 (0.41) diameter flux core solder wire or solder paste. Use a
minimum amount of solder and heat for a good joint. Do not
allow heat to build up for a long period of time as cable stop
may melt.
6. After solder joint has cooled, remove cable from vise. Remove
any excess solder from contact with a sharp blade and clean all
debris from contact and cable.
7. Insert contact into connector assembly, making sure cable stop
bottoms out against internal shoulder of connector body. Insert
connector assembly into interface location fixture and clamp
cable in vise. Make sure connector assembly is fully engaged
within location fixture. Tighten stop screw until light pressure is
applied between connector assembly and cable stop.
8. Solder end of connector body to cable jacket, using a minimum
amount of solder and heat for a full fillet joint. Allow assembly to
cool before removing connector from vise and location fixture.
Best results are obtained when contact location is flush to .004
(0.10) recessed from reference plane. Interface location fixture
is pre-set at factory, but can be adjusted to control location.
Cable Group
Part Number
MIL-C-17/151, .047 Semi-Rigid
127-0692-001
Tool
Part Number
Cable Vise
Stop Screw
Clamp Inserts
Contact Holder
Interface Location Fixture
140-0000-962
140-0000-981
140-0000-997
127-0000-902
127-0000-903
14
Connectivity for
Business-Critical Continuity
SMP Connectors
Assembly Instructions
SMP Right Angle Female Solder Style for .047 OD Semi-Rigid Cable
1. Identify tools (5 piece parts) and connector parts (3 piece parts).
2. Strip cable jacket and dielectric to dimension shown. Do not
nick center conductor. Clean all debris from prepared cable.
3. Insert center conductor into cable stop as shown. Make sure
slot in connector contact is aligned with cross hole in body as
shown. Insert cable into cross hole in connector body, making
sure cable stop bottoms out against internal shoulder of
connector body.
4. Insert connector assembly into interface location fixture and
clamp cable in vise using body holder fixture as shown. Tighten
stop screw until light pressure is applied between connector
body, cable stop and cable jacket.
5. Solder contact to center conductor through rear access port in
connector body using a minimum amount of solder and heat for a
good joint.
6. After center conductor solder joint has cooled, solder connector
body to cable jacket, using a minimum amount of solder and heat
for a full fillet joint. Take care so that solder does not flow onto
anti-rock ring or into rear access port. Allow assembly to cool
before removing connector from vise and location fixture.
7. Using a fixture plate as shown, press end cap into rear access
port using a .156 (3.96) diameter flat punch until fully seated
within body counter bore.
8. Best results are obtained when contact location is flush to .004
(0.10) recessed from reference plane. Interface location fixture
is pre-set at factory, but can be adjusted to control location.
Cable Group
Part Number
MIL-C-17/151, .047 Semi-Rigid
127-0692-101
Tool
Part Number
Cable Vise
Stop Screw
Clamp Inserts
Body Holder
Interface Location Fixture
140-0000-962
140-0000-981
140-0000-997
127-0000-904
127-0000-903
15
Connectivity for
Business-Critical Continuity
SMP Connectors
Assembly Instructions
SMP Straight Female Solder Style for .086 OD Semi-Rigid Cable
1. Identify tools (6 piece parts) and connector parts (2 piece parts).
2. Strip cable jacket and dielectric to dimension shown. Do not
nick center conductor. Clean all debris from prepared cable.
3. Place contact onto center conductor, insert solder shim between
cable jacket and contact.
4. Insert contact into contact holder fixture and clamp cable in vise.
Tighten stop screw until light pressure is applied between contact, solder shim and cable jacket.
5. Solder contact to center conductor through solder hole using
.016 (0.41) diameter flux core solder wire or solder paste. Use a
minimum amount of solder and heat for a good joint. Do not
allow heat to build up for a long period of time as cable dielectric
will expand.
6. After solder joint has cooled, remove solder shim and cable from
vise. Remove any excess solder from contact with a sharp blade
and clean all debris from contact and cable.
7. Insert contact into connector assembly, making sure cable
jacket bottoms out against internal shoulder of connector body.
Insert connector assembly into interface location fixture and
clamp cable in vise. Make sure connector assembly is fully engaged within location fixture. Tighten stop screw until light pressure is applied between connector assembly and cable jacket.
8. Solder end of connector body to cable jacket, using a minimum
amount of solder and heat for a full fillet joint. Allow assembly to
cool before removing connector from vise and location fixture.
Best results are obtained when contact location is flush to .004
(0.10) recessed from reference plane. Interface location fixture
is pre-set at factory, but can be adjusted to control location.
Cable Group
Part Number
RG-405, .086 Semi-Rigid
127-0693-001
Tool
Part Number
Cable Vise
Stop Screw
Clamp Inserts
Solder Shim
Contact Holder
Interface Location Fixture
140-0000-962
140-0000-981
140-0000-964
140-0000-984
127-0000-902
127-0000-903
16
Connectivity for
Business-Critical Continuity
SMP Connectors
Assembly Instructions
SMP Right Angle Female Solder Style for .086 OD Semi-Rigid Cable
1. Identify tools (5 piece parts) and connector parts (2 piece parts).
2. Strip cable jacket and dielectric to dimension shown. Do not
nick center conductor. Clean all debris from prepared cable.
3. Make sure slot in connector contact is aligned with cross hole in
body as shown. Insert cable into cross hole in connector body,
making sure cable jacket bottoms out against internal shoulder
of connector body.
4. Insert connector assembly into interface location fixture and
clamp cable in vise using body holder fixture as shown. Tighten
stop screw until light pressure is applied between connector
body and cable jacket.
5. Solder contact to center conductor through rear access port in
connector body using a minimum amount of solder and heat for a
good joint. Do not allow solder to build up along exposed center
conductor.
6. After center conductor solder joint has cooled, solder connector
body to cable jacket, using a minimum amount of solder and heat
for a full fillet joint. Take care so that solder does not flow onto
anti-rock ring or into rear access port. Allow assembly to cool
before removing connector from vise and location fixture.
7. Using a fixture plate as shown, press end cap into rear access
port using a .156 (3.96) diameter flat punch until fully seated
within body counter bore.
8. Best results are obtained when contact location is flush to .004
(0.10) recessed from reference plane. Interface location fixture
is pre-set at factory, but can be adjusted to control location.
Cable Group
Part Number
RG-405, .086 Semi-Rigid
127-0693-101
Tool
Part Number
Cable Vise
Stop Screw
Clamp Inserts
Body Holder
Interface Location Fixture
140-0000-962
140-0000-981
140-0000-964
127-0000-904
127-0000-903
17
Connectivity for
Business-Critical Continuity
SMP Connectors
Assembly Instructions
SMP Hermetic Seal Installation
1. Prepare housing panel per figure 2 as shown on page 7.
2. Install solder ring on hermetic seal as shown. Recommended
ring size is .103 (2.62) ID x .128 (3.25) OD x .015 (0.38) Thick.
3. Solder in place as shown.
Interface
Part Number
Full Detent
Limited Detent
Smooth Bore
127-0711-601
127-1711-601
127-2711-601
SMP Shroud Installation
1. Install appropriate assembly tool into shroud as shown.
2. While holding tool in place, align flange mount with mounting
holes in panel. Install fasteners and torque to 6-8 in/lbs.
Shroud Part Number
Tool Part Number
127-0701-602
127-1701-602
127-2701-602
127-3701-602
127-0000-905
127-0000-906
127-0000-907
127-0000-907
18
Connectivity for
Business-Critical Continuity
SMP Connectors
Cross Reference
COMPETITOR CROSS REFERENCE
Description
Johnson
Tensolite
Corning Gilbert Micro-Mode
SV Microwave
AEP
Rosenberger
Straight Female M17/151 (.047 SR) Cabled
Straight Female RG 405 (.086 SR) Cabled
Right Angle Female M17/151 (.047 SR) Cabled
Right Angle Female RG 405 (.086 SR) Cabled
Field Replaceable .012 Socket 2 Hole Flange Male FD
Field Replaceable .012 Socket 2 Hole Flange Male LD
Field Replaceable .012 Socket 2 Hole Flange Male SB
Adapter Bullet Female/Female .254
Adapter Female/Female .769
Adapter Male CM/Male FD
Adapter Male CM/Male LD
Adapter Male CM/Male SB
Shroud 2 Hole Flange .165 Wide x .400 High FD
Shroud 2 Hole Flange .165 Wide x .400 High LD
Shroud 2 Hole Flange .165 Wide x .400 High SB
Shroud 2 Hole Flange .235 Wide x .470 High CM
PC Mount Straight .218 OD .100 Legs Male FD
PC Mount Straight .218 OD .100 Legs Male LD
PC Mount Straight .218 OD .100 Legs Male SB
PC Mount Straight .235 OD .100 Legs Male CM
End Launch Surface Mount Male FD
End Launch Surface Mount Male LD
End Launch Surface Mount Male SB
Hermetic Feedthrough Shroud Male FD
Hermetic Feedthrough Shroud Male LD
Hermetic Feedthrough Shroud Male SB
127-0692-001
127-0693-001
127-0692-101
127-0693-101
127-0701-612
127-1701-612
127-2701-612
127-0901-801
127-0901-811
127-0901-822
127-1901-822
127-2901-822
127-0701-602
127-1701-602
127-2701-602
127-3701-602
127-0701-201
127-1701-201
127-2701-201
127-3701-201
127-0701-801
127-1701-801
127-2701-801
127-0711-601
127-1711-601
127-2711-601
P651-1CC
P651-2CC
P652-1CC
P652-2CC
P836-4CCF
P836-5CCF
P836-6CCF
P650-1CC
P617-1CC
P912-1CCSF
P912-2CCSF
P912-3CCSF
P670-3SF
P672-3SF
P673-3SF
P671-1SF
P654-5CC
P654-6CC
P654-7CC
P654-8CC
P606-1CC
P606-2CC
P606-3CC
P840-9CC
P794-2CC
A014-B11-01
A014-D11-01
A015-B11-01
A015-D11-01
MMSP-6120
MMSP-2508
MMSP-6968
MMSP-2598
1203-4000
1204-4000
1213-4006
1214-4001
SF1250-6000
7500-1582-011
7500-1562-010
7501-1562-011
7501-1562-010
19K101-270E4
19K101-271E4
19K202-270E4
19K202-271E4
A1A1-0001-01
MMSP-2500
MMSP-3829
1290-4004
1290-4007
5280-1502-000
5280-1502-001
19K101-K00E4
19K115-K00E4
A001-A23-04
A001-A24-04
A001-A25-04
MMSP-2514
MMSP-6095
MMSP-6067
SF1293-6004
SF1254-6006
SF1254-6007
SF1254-6008
A008-L33-01
A008-L34-01
A008-L35-01
MMSP-7448
MMSP-7449
A010-L13-02
A010-L14-02
A010-L15-02
A007-L43-01-70
A007-L44-01-70
A007-L45-01-70
MMSP-7457
MMSP-3805
MMSP-7347
MMSP-2771
MMSP-2875
MMSP-2979
A3A6-0539-01
SF1287-6001
19S202-40ME4
19
Emerson Network Power Connectivity Solutions
Johnson
299 Johnson Avenue
Waseca, MN 56093
USA
Tel: 800.247.8256
Fax: 507.833.6287
www.EmersonNetworkPower.com/Connectivity
About Emerson Network Power
Connectivity Solutions
Emerson Network Power Connectivity Solutions,
an Emerson business, serves the needs of
wireless communications, telephony and data
networks, CATV, security systems, health care
and industrial facilities with a full spectrum of
broadband copper and fiber optic connectivity
products. For more information, visit
www.EmersonNetworkPower.com/Connectivity
About Emerson
Emerson (NYSE: EMR), based in St. Louis, is a
global leader in bringing technology and engineering together to provide innovative solutions
to customers through its network power, process
management, industrial automation, climate
technologies, appliance and tools businesses. For
more information, visit www.Emerson.com
EmersonNetworkPower. com
Emerson Network Power
The global leader in enabling business-critical continuity.
AC Power Systems
Connectivity
DC Power Systems
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2006 Emerson Electric Co
20
SMP11/07