Connectivity for Business-Critical Continuity Type SMP Connectors Product Catalog Connectivity for Business-Critical Continuity SMP Connectors Table of Content Table of Contents PAGE Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-8 Mounting Holes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-12 Assembly Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Assembly Instructions . . . . . . . . . . . . . . . . . . . . . . . . . .14-18 Competitor Cross Reference . . . . . . . . . . . . . . . . . . . . . . .19 2 Connectivity for Business-Critical Continuity SMP Connectors Introduction SMP Blind-Mate Connectors Emerson’s new Johnson® line of SMP Blind-Mate Connectors offers our customers a Micro-Miniature, Slide-On/Snap-On Interconnect System that aid’s in the design ofhigh-density packaging as well as axial and radial misalignment issues. The SMP Interface offers superior performance up to 40 GHz and is compatible with all SMP and GPO® Connectors. They offer high electrical reliability where extreme shock and vibration condition’s are experienced. Applications (Military and Commercial) • Phased Arrays • Active Antennas • Satellites • Communication Equipment • Airborne Radar •Shipborne Radar •Ground Radar • Hi-Density Modular Packaging • Axial/ Radial Misalignment Solutions • Aerospace • Broadband • Instrumentation • Telecom • Defense • Microwave Markets Transmission Options • • • • Box-to-Box Cable-to-Board Board-to-Board Cable-to-Panel-to-Board *GPO® is a registered trademark of Corning Gilbert. 3 Connectivity for Business-Critical Continuity SMP Connectors Introduction Description One of the key benefits of the SMP connector interface is its use in high frequency blind-mate applications. The design of the SMP bullet and shroud system allows for both axial and radial misalignment. The basic system is comprised of an inner “bullet” adapter, and two outer receptacles called “shrouds”. The bullet provides a flexible link between the shroud connections. In blind-mate applications, one shroud connector will be typically specified as a snap-on interface and the other as a slide-on. This ensures that the bullet adapter remains fixed in the same shroud connector when the connection is disengaged. The two snap-on interfaces Full Detent (FD) and Limited Detent (LD) each have different engage and disengage coupling forces. The LD is typically selected as the snap-on interface in PCB mount or blind-mate applications, while the FD is mainly used for cabled connections where higher retention forces are required. The two slide-on interfaces Smooth Bore (SM) and Catcher’s Mit (CM) allow for reduced connection forces as compared to the snap-on versions. The push-on interface creates a sliding connection that does not physically locate the mating reference planes, allowing for axial and radial misalignment. Both the SM and CM have the same engage/disengage forces; however the CM is typically specified as the shroud configuration in blind-mate applications as its generous lead-in chamfer helps capture and guide the bullet into place. Radial Misalignment Axial Misalignment Bullet Length Shroud 4 Connectivity for Business-Critical Continuity SMP Connectors Specifications ELECTRICAL SPECIFICATIONS Impedance: 50 Ohms Frequency Range: Bullet Adapter (.254 length), Semi-Rigid Straight Cabled Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-40 GHz All other In-Series Adapters, Semi-Rigid Right Angle Cabled Connectors, Field Replaceable Connectors, End Launch Connectors, Hermetic Feedthroughs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-18 GHz PC Mount Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-12 GHz VSWR: (maximum) 0-18 GHz 18-23 GHz Bullet Adapter (.254 length) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.10 1.15 0-18 GHz Semi-Rigid Straight Cabled Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 0-4 GHz All other In-Series Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.10 23-26.5 GHz 1.30 18-26.5 GHz 1.35 4-12 GHz 1.15 26.5-40 GHz 1.70 26.5-40 GH 1.70 12-18 GHz 1.20 0-18 GHz Semi-Rigid Right Angle Cabled Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.20 0-18 GHz Field Replaceable Connectors (typical, measured back to back with seal pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.15 Un-cabled Connectors (dependant on application) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not Applicable Insertion Loss: (dB maximum, tested at 10 GHz) In-Series Adapters, Field Replaceable Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.10 √ F (GHz) Semi-Rigid Cabled Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.12 √ F (GHz) All other Un-cabled Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not Applicable Working Voltage: 335 Vrms maximum at sea level, 65 Vrms maximum at 70,000 feet Dielectric Withstanding: Voltage: 500 Vrms minimum at sea level RF High Potential Withstanding Voltage: 325 Vrms minimum at sea level, tested at 4 and 7 MHz Corona Level: 190 Vrms minimum at 70,000 feet Contact Resistance: (milliohms maximum initial, not applicable after environmental testing) Center Contact (Connectors and Adapters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.0 Outer Contact (Connectors and Adapters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.0 Cable Shield to Body (Semi-Rigid Cabled Connectors Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 Insulation Resistance: 5000 megohms minimum RF Leakage: (dB typical, tested at 2.5 GHz) Cabled and Field Replaceable Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -80 In-Series Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65 All other Un-cabled Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Not Applicable 5 Connectivity for Business-Critical Continuity SMP Connectors Specifications MECHANICAL SPECIFICATIONS Interface Design: MIL-STD-348A, Series SMP Engagement Force: (pounds maximum, mated pair) Full Detent (FD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.0 Limited Detent (LD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.0 Smooth Bore and Catcher’s Mit (SM and CM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.0 Disengagement Force: (pounds minimum, mated pair) Full Detent (FD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.0 Limited Detent (LD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.0 Smooth Bore and Catcher’s Mit (SM and CM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 Mated Radial Misalignment: (inches maximum allowed, female adapters only) Between Centerlines of Mating Planes (FD, LD, SM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .010 Between Centerlines of Mating Planes (CM only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .020 Mated Axial Misalignment: .010 inches maximum allowed between mating planes (female adapters only) Durability: (mating cycles minimum) Full Detent (all female connectors and adapters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Limited Detent (female adapters only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500 Smooth Bore and Catcher’s Mit (female adapters only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 Contact Retention: 1.5 pounds minimum axial force (captivated contacts only) Cable Retention: (minimum) Axial Force* (lbs) Cabled Connectors for RG-405 (.086 Semi-Rigid) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Cabled Connectors for M17/151 (.047 Semi-Rigid) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Torque (in-oz) 16.0 N/A *Or cable breaking strength, whichever is less Typical Measured Return Loss Bullet Adapter 127-0901-801 127-0801-901 VSWR = 1.10 (0-18 GHz), 1.15 (18-23 GHz), 1.30 (23-26.5 GHz), 1.70 (26.5-40 GHz) 0 -10 S11 (dB) -20 -30 -40 -50 -60 0 5 10 15 20 Frequency (GHz) 6 25 30 35 40 Connectivity for Business-Critical Continuity SMP Connectors Specifications ENVIRONMENTAL SPECIFICATIONS (Meets or Exceeds the Applicable Paragraph of MIL-PRF-39012) Operating Temperature: -65°C to +165°C Thermal Shock: MIL-STD-202, Method 107, Condition B (except high temp +165°C or max high temp of cable) Corrosion: MIL-STD-202, Method 101, Condition B Shock (specified pulse): MIL-STD-202, Method 213, Condition I Vibration: MIL-STD-202, Method 204, Condition D Moisture Resistance: MIL-STD-202, Method 106 (except step 7b omitted) MATERIAL SPECIFICATIONS Spring Finger (female) and End Launch (male) Bodies: Beryllium Copper per ASTM B196, Gold* plated per MIL-DTL-45204 (.00005” min) Hermetic Seal Bodies (male): Kovar Alloy per ASTM F15, Gold* plated per MIL-DTL-45204 (.00005” min) All other Shroud Bodies (male): Stainless Steel, Type 303, per ASTM A582, Passivated per MIL-DTL-14072 (EL 300) Connector and Adapter Contacts (male and female): Beryllium Copper per ASTM B196, Gold* plated per MIL-DTL-45204 (.00005” min) Hermetic Seal Center Pins: Kovar Alloy per ASTM F15, Gold* plated per MIL-DTL-45204 (.00005” min) EMI/Anti-Rock Rings: Beryllium Copper per ASTM B196, Gold* plated per MIL-DTL-45204 (.00003” min) PC Mount Legs: Brass per ASTM B16, Gold* plated per MIL-DTL-45204 (.00003” min) Connector and Adapter Insulators: PTFE per ASTM D1710 Hermetic Seal Glass: Corning 7070 *All gold plated parts include a .00005” min nickel barrier layer. MOUNTING HOLES Fig 1 Fig 2 Fig 3 This pattern is for reference only. Pattern will vary depending on board type and specific electrical and mechanical requirements. 7 Connectivity for Business-Critical Continuity SMP Connectors Specifications Mating Engagement for SMP Series per MIL-STD-348A Notes: 1. Socket to accept mating pin Ø.015±.001 (0.38±0.03). 2. EMI/Anti-Rock Ring configuration optional, used on cabled connectors only. Shall not prevent proper mating engagement. 3. All dimensions shown in inches. Metric equivalents (rounded to nearest 0.01mm) are given for general information only. SMP Female Connector Interface Dimension A Cabled Uncabled Minimum Maximum Minimum Maximum .025 (0.64) .035 (0.89) .018 (0.46) .025 (0.64) SMP Male Connector Interface Dimension B C D E F G H K M 8 Full Detent Minimum Maximum Limited Detent Minimum Maximum Smooth Bore Minimum Maximum Catcher’s Mit Minimum Maximum .051 (1.30) .0205 (0.52) .003 (0.08) .033 (0.84) .139 (3.53) .114 (2.90) .124 (3.15) 35° REF 30° REF .054 (1.37) .0205 (0.52) .003 (0.08) .033 (0.84) .139 (3.53) .118 (3.00) .124 (3.15) 35° REF 30° REF .059 (1.50) N/A .003 (0.08) .033 (0.84) .139 (3.53) .123 (3.12) N/A 35° REF N/A N/A N/A .043 (1.09) N/A .123 (3.12) N/A N/A N/A N/A .057 (1.45) .0235 (0.60) .008 (0.20) .037 (0.94) .145 (3.68) .118 (3.00) .126 (3.20) 35° REF 30° REF .060 (1.52) .0235 (0.60) .008 (0.20) .037 (0.94) .145 (3.68) .122 (3.10) .126 (3.20) 35° REF 30° REF .065 (1.65) N/A .008 (0.20) .037 (0.94) .145 (3.68) .127 (3.23) N/A 35° REF N/A N/A N/A .047 (1.19) N/A .127 (3.23) N/A N/A N/A N/A Connectivity for Business-Critical Continuity SMP Connectors Application Straight Solder Type Cabled Female Fig 1 Cable Type VSWR & Freq. Range* M17/151, .047 Semi-Rigid 1.20 Max 0-18 GHz, 1.35 Max 18-26.5 GHz, 1.70 Max 26.5-40 GHz RG-405, .086 Semi-Rigid 1.20 Max 0-18 GHz, 1.35 Max 18-26.5 GHz, 1.70 Max 26.5-40 GHz Gold Plated Figure 127-0692-001 1 127-0693-001 2 Fig 2 * Specifications dependant on cable ratings Right Angle Solder Type Cabled Female Cable Type VSWR & Freq. Range Gold Plated “A” M17/151, .047 Semi-Rigid 1.20 Max 0-18 GHz RG-405, .086 Semi-Rigid 1.20 Max 0-18 GHz “B” 127-0692-101 .248 (6.30) .197 (5.00) 127-0693-101 .271 (6.88) .209 (5.31) Straight PC Mount Male Receptacle Interface Freq. Range Passivated* “A” Full Detent Limited Detent Smooth Bore Catcher’s Mit 0-12 GHz 0-12 GHz 0-12 GHz 0-12 GHz 127-0701-201 127-1701-201 127-2701-201 127-3701-201 .218 (5.54) .218 (5.54) .218 (5.54) .234 (5.94) * Base and legs Gold plated brass Mounting hole layout figure 3 on page 7. 9 Connectivity for Business-Critical Continuity SMP Connectors Application End Launch Male Receptacle – Surface Mount Interface Freq. Range Gold Plated Packaging Full Detent Full Detent Limited Detent Limited Detent Smooth Bore Smooth Bore 0-18 GHz 0-18 GHz 0-18 GHz 0-18 GHz 0-18 GHz 0-18 GHz Stock Tape and Reel -1000 pieces Stock Tape and Reel -1000 pieces Stock Tape and Reel -1000 pieces 127-0701-801 127-0701-802 127-1701-801 127-1701-802 127-2701-801 127-2701-802 Mounting hole layout figure 1 on page 7. 2-Hole Flange Mount Male Shroud - Without Contact Interface Passivated Full Detent Limited Detent Smooth Bore 127-0701-602 127-1701-602 127-2701-602 2-Hole Flange Mount Male Catcher’s Mit Shroud - Without Contact Interface Passivated Catcher’s Mit 127-3701-602 10 Connectivity for Business-Critical Continuity SMP Connectors Application 2-Hole Flange Mount Male Field Replaceable Interface VSWR & Freq. Range* Passivated Accepts Pin Size Full Detent Limited Detent Smooth Bore 1.15 Typical 0-18 GHz 1.15 Typical 0-18 GHz 1.15 Typical 0-18 GHz 127-0701-612 127-1701-612 127-2701-612 .012 (.030) .012 (.030) .012 (.030) * Two connectors mated back to back with hermetic seal fixture Hermetic Seal Male Interface Freq. Range Gold Plated Full Detent Limited Detent Smooth Bore 0-18 GHz 0-18 GHz 0-18 GHz 127-0711-601 127-1711-601 127-2711-601 Mounting hole layout figure 2 on page 7. Female to Female Bullet Adapter VSWR & Freq. Range Gold Plated 1.10 Max 0-18 GHz, 1.15 Max 18-23 GHz, 1.30 Max 23-26.5 GHz, 1.70 Max 26.5-40 GHz 127-0901-801 11 Connectivity for Business-Critical Continuity SMP Connectors Application Female to Female Adapter VSWR & Freq. Range Gold Plated 1.10 Max 0-4 GHz, 1.15 Max 4-12 GHz, 1.20 Max 12-18 GHz 127-0901-811 Male to Male Catcher’s Mit Adapter Interface VSWR & Freq. Range Passivated Full Detent 1.10 Max 0-4 GHz, 1.15 Max 4-12 GHz, 1.20 Max 12-18 GHz 1.10 Max 0-4 GHz, 1.15 Max 4-12 GHz, 1.20 Max 12-18 GHz 1.10 Max 0-4 GHz, 1.15 Max 4-12 GHz, 1.20 Max 12-18 GHz 127-0901-821 Limited Detent Smooth Bore 12 127-1901-821 127-2901-821 Connectivity for Business-Critical Continuity SMP Connectors Assembly Tools SMP Customer Tooling Accurate assembly of the Semi-Rigid Cabled Connectors is obtained with the tools listed below. Industry standard devices are used if possible for customer convenience and tool compatibility. E. C. F. B. G. D. H. A. I. Item Description Part Number A B C D E SMP Bullet Extraction Tool SMP Cabled Connector Removal Tool Soldering Vise (does not include clamp inserts or stop screw) Stop Screw for Soldering Vise Semi-Rigid Cable Clamp Inserts for .086" OD Cable Semi-Rigid Cable Clamp Inserts for .047" OD Cable Solder Shim for .086" OD Cable SMP Center Contact Holder SMP Interface Locator Tool SMP Right Angle Body Holder SMP FD Shroud Centering Tool SMP LD Shroud Centering Tool SMP SB Shroud Centering Tool 127-0000-900 127-0000-901 140-0000-962 140-0000-981 140-0000-964 140-0000-997 140-0000-984 127-0000-902 127-0000-903 127-0000-904 127-0000-905 127-0000-906 127-0000-907 F G H I J J. 13 Connectivity for Business-Critical Continuity SMP Connectors Assembly Instructions ASSEMBLY INSTRUCTIONS SMP Straight Female Solder Style for .047 OD Semi-Rigid Cable 1 Identify tools (5 piece parts) and connector parts (3 piece parts). 2. Strip cable jacket and dielectric to dimension shown. Do not nick center conductor. Clean all debris from prepared cable. 3. Insert center conductor into cable stop as shown and place contact onto center conductor. 4. Insert contact into contact holder fixture and clamp cable in vise. Tighten stop screw until light pressure is applied between contact, cable stop and cable jacket. 5. Solder contact to center conductor through solder hole using .016 (0.41) diameter flux core solder wire or solder paste. Use a minimum amount of solder and heat for a good joint. Do not allow heat to build up for a long period of time as cable stop may melt. 6. After solder joint has cooled, remove cable from vise. Remove any excess solder from contact with a sharp blade and clean all debris from contact and cable. 7. Insert contact into connector assembly, making sure cable stop bottoms out against internal shoulder of connector body. Insert connector assembly into interface location fixture and clamp cable in vise. Make sure connector assembly is fully engaged within location fixture. Tighten stop screw until light pressure is applied between connector assembly and cable stop. 8. Solder end of connector body to cable jacket, using a minimum amount of solder and heat for a full fillet joint. Allow assembly to cool before removing connector from vise and location fixture. Best results are obtained when contact location is flush to .004 (0.10) recessed from reference plane. Interface location fixture is pre-set at factory, but can be adjusted to control location. Cable Group Part Number MIL-C-17/151, .047 Semi-Rigid 127-0692-001 Tool Part Number Cable Vise Stop Screw Clamp Inserts Contact Holder Interface Location Fixture 140-0000-962 140-0000-981 140-0000-997 127-0000-902 127-0000-903 14 Connectivity for Business-Critical Continuity SMP Connectors Assembly Instructions SMP Right Angle Female Solder Style for .047 OD Semi-Rigid Cable 1. Identify tools (5 piece parts) and connector parts (3 piece parts). 2. Strip cable jacket and dielectric to dimension shown. Do not nick center conductor. Clean all debris from prepared cable. 3. Insert center conductor into cable stop as shown. Make sure slot in connector contact is aligned with cross hole in body as shown. Insert cable into cross hole in connector body, making sure cable stop bottoms out against internal shoulder of connector body. 4. Insert connector assembly into interface location fixture and clamp cable in vise using body holder fixture as shown. Tighten stop screw until light pressure is applied between connector body, cable stop and cable jacket. 5. Solder contact to center conductor through rear access port in connector body using a minimum amount of solder and heat for a good joint. 6. After center conductor solder joint has cooled, solder connector body to cable jacket, using a minimum amount of solder and heat for a full fillet joint. Take care so that solder does not flow onto anti-rock ring or into rear access port. Allow assembly to cool before removing connector from vise and location fixture. 7. Using a fixture plate as shown, press end cap into rear access port using a .156 (3.96) diameter flat punch until fully seated within body counter bore. 8. Best results are obtained when contact location is flush to .004 (0.10) recessed from reference plane. Interface location fixture is pre-set at factory, but can be adjusted to control location. Cable Group Part Number MIL-C-17/151, .047 Semi-Rigid 127-0692-101 Tool Part Number Cable Vise Stop Screw Clamp Inserts Body Holder Interface Location Fixture 140-0000-962 140-0000-981 140-0000-997 127-0000-904 127-0000-903 15 Connectivity for Business-Critical Continuity SMP Connectors Assembly Instructions SMP Straight Female Solder Style for .086 OD Semi-Rigid Cable 1. Identify tools (6 piece parts) and connector parts (2 piece parts). 2. Strip cable jacket and dielectric to dimension shown. Do not nick center conductor. Clean all debris from prepared cable. 3. Place contact onto center conductor, insert solder shim between cable jacket and contact. 4. Insert contact into contact holder fixture and clamp cable in vise. Tighten stop screw until light pressure is applied between contact, solder shim and cable jacket. 5. Solder contact to center conductor through solder hole using .016 (0.41) diameter flux core solder wire or solder paste. Use a minimum amount of solder and heat for a good joint. Do not allow heat to build up for a long period of time as cable dielectric will expand. 6. After solder joint has cooled, remove solder shim and cable from vise. Remove any excess solder from contact with a sharp blade and clean all debris from contact and cable. 7. Insert contact into connector assembly, making sure cable jacket bottoms out against internal shoulder of connector body. Insert connector assembly into interface location fixture and clamp cable in vise. Make sure connector assembly is fully engaged within location fixture. Tighten stop screw until light pressure is applied between connector assembly and cable jacket. 8. Solder end of connector body to cable jacket, using a minimum amount of solder and heat for a full fillet joint. Allow assembly to cool before removing connector from vise and location fixture. Best results are obtained when contact location is flush to .004 (0.10) recessed from reference plane. Interface location fixture is pre-set at factory, but can be adjusted to control location. Cable Group Part Number RG-405, .086 Semi-Rigid 127-0693-001 Tool Part Number Cable Vise Stop Screw Clamp Inserts Solder Shim Contact Holder Interface Location Fixture 140-0000-962 140-0000-981 140-0000-964 140-0000-984 127-0000-902 127-0000-903 16 Connectivity for Business-Critical Continuity SMP Connectors Assembly Instructions SMP Right Angle Female Solder Style for .086 OD Semi-Rigid Cable 1. Identify tools (5 piece parts) and connector parts (2 piece parts). 2. Strip cable jacket and dielectric to dimension shown. Do not nick center conductor. Clean all debris from prepared cable. 3. Make sure slot in connector contact is aligned with cross hole in body as shown. Insert cable into cross hole in connector body, making sure cable jacket bottoms out against internal shoulder of connector body. 4. Insert connector assembly into interface location fixture and clamp cable in vise using body holder fixture as shown. Tighten stop screw until light pressure is applied between connector body and cable jacket. 5. Solder contact to center conductor through rear access port in connector body using a minimum amount of solder and heat for a good joint. Do not allow solder to build up along exposed center conductor. 6. After center conductor solder joint has cooled, solder connector body to cable jacket, using a minimum amount of solder and heat for a full fillet joint. Take care so that solder does not flow onto anti-rock ring or into rear access port. Allow assembly to cool before removing connector from vise and location fixture. 7. Using a fixture plate as shown, press end cap into rear access port using a .156 (3.96) diameter flat punch until fully seated within body counter bore. 8. Best results are obtained when contact location is flush to .004 (0.10) recessed from reference plane. Interface location fixture is pre-set at factory, but can be adjusted to control location. Cable Group Part Number RG-405, .086 Semi-Rigid 127-0693-101 Tool Part Number Cable Vise Stop Screw Clamp Inserts Body Holder Interface Location Fixture 140-0000-962 140-0000-981 140-0000-964 127-0000-904 127-0000-903 17 Connectivity for Business-Critical Continuity SMP Connectors Assembly Instructions SMP Hermetic Seal Installation 1. Prepare housing panel per figure 2 as shown on page 7. 2. Install solder ring on hermetic seal as shown. Recommended ring size is .103 (2.62) ID x .128 (3.25) OD x .015 (0.38) Thick. 3. Solder in place as shown. Interface Part Number Full Detent Limited Detent Smooth Bore 127-0711-601 127-1711-601 127-2711-601 SMP Shroud Installation 1. Install appropriate assembly tool into shroud as shown. 2. While holding tool in place, align flange mount with mounting holes in panel. Install fasteners and torque to 6-8 in/lbs. Shroud Part Number Tool Part Number 127-0701-602 127-1701-602 127-2701-602 127-3701-602 127-0000-905 127-0000-906 127-0000-907 127-0000-907 18 Connectivity for Business-Critical Continuity SMP Connectors Cross Reference COMPETITOR CROSS REFERENCE Description Johnson Tensolite Corning Gilbert Micro-Mode SV Microwave AEP Rosenberger Straight Female M17/151 (.047 SR) Cabled Straight Female RG 405 (.086 SR) Cabled Right Angle Female M17/151 (.047 SR) Cabled Right Angle Female RG 405 (.086 SR) Cabled Field Replaceable .012 Socket 2 Hole Flange Male FD Field Replaceable .012 Socket 2 Hole Flange Male LD Field Replaceable .012 Socket 2 Hole Flange Male SB Adapter Bullet Female/Female .254 Adapter Female/Female .769 Adapter Male CM/Male FD Adapter Male CM/Male LD Adapter Male CM/Male SB Shroud 2 Hole Flange .165 Wide x .400 High FD Shroud 2 Hole Flange .165 Wide x .400 High LD Shroud 2 Hole Flange .165 Wide x .400 High SB Shroud 2 Hole Flange .235 Wide x .470 High CM PC Mount Straight .218 OD .100 Legs Male FD PC Mount Straight .218 OD .100 Legs Male LD PC Mount Straight .218 OD .100 Legs Male SB PC Mount Straight .235 OD .100 Legs Male CM End Launch Surface Mount Male FD End Launch Surface Mount Male LD End Launch Surface Mount Male SB Hermetic Feedthrough Shroud Male FD Hermetic Feedthrough Shroud Male LD Hermetic Feedthrough Shroud Male SB 127-0692-001 127-0693-001 127-0692-101 127-0693-101 127-0701-612 127-1701-612 127-2701-612 127-0901-801 127-0901-811 127-0901-822 127-1901-822 127-2901-822 127-0701-602 127-1701-602 127-2701-602 127-3701-602 127-0701-201 127-1701-201 127-2701-201 127-3701-201 127-0701-801 127-1701-801 127-2701-801 127-0711-601 127-1711-601 127-2711-601 P651-1CC P651-2CC P652-1CC P652-2CC P836-4CCF P836-5CCF P836-6CCF P650-1CC P617-1CC P912-1CCSF P912-2CCSF P912-3CCSF P670-3SF P672-3SF P673-3SF P671-1SF P654-5CC P654-6CC P654-7CC P654-8CC P606-1CC P606-2CC P606-3CC P840-9CC P794-2CC A014-B11-01 A014-D11-01 A015-B11-01 A015-D11-01 MMSP-6120 MMSP-2508 MMSP-6968 MMSP-2598 1203-4000 1204-4000 1213-4006 1214-4001 SF1250-6000 7500-1582-011 7500-1562-010 7501-1562-011 7501-1562-010 19K101-270E4 19K101-271E4 19K202-270E4 19K202-271E4 A1A1-0001-01 MMSP-2500 MMSP-3829 1290-4004 1290-4007 5280-1502-000 5280-1502-001 19K101-K00E4 19K115-K00E4 A001-A23-04 A001-A24-04 A001-A25-04 MMSP-2514 MMSP-6095 MMSP-6067 SF1293-6004 SF1254-6006 SF1254-6007 SF1254-6008 A008-L33-01 A008-L34-01 A008-L35-01 MMSP-7448 MMSP-7449 A010-L13-02 A010-L14-02 A010-L15-02 A007-L43-01-70 A007-L44-01-70 A007-L45-01-70 MMSP-7457 MMSP-3805 MMSP-7347 MMSP-2771 MMSP-2875 MMSP-2979 A3A6-0539-01 SF1287-6001 19S202-40ME4 19 Emerson Network Power Connectivity Solutions Johnson 299 Johnson Avenue Waseca, MN 56093 USA Tel: 800.247.8256 Fax: 507.833.6287 www.EmersonNetworkPower.com/Connectivity About Emerson Network Power Connectivity Solutions Emerson Network Power Connectivity Solutions, an Emerson business, serves the needs of wireless communications, telephony and data networks, CATV, security systems, health care and industrial facilities with a full spectrum of broadband copper and fiber optic connectivity products. For more information, visit www.EmersonNetworkPower.com/Connectivity About Emerson Emerson (NYSE: EMR), based in St. Louis, is a global leader in bringing technology and engineering together to provide innovative solutions to customers through its network power, process management, industrial automation, climate technologies, appliance and tools businesses. For more information, visit www.Emerson.com EmersonNetworkPower. com Emerson Network Power The global leader in enabling business-critical continuity. AC Power Systems Connectivity DC Power Systems Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2006 Emerson Electric Co 20 SMP11/07