ETC 1PT100

1 Pt100 KN 1515
The KN Series Ceramic Wire Wound PRTDs are suitable for
general applications requiring temperature stability.
Applications: Industrial resistance thermometers, especially
in chemical, power generation plants and analytical
equipment.
Construction: A platinum coil is sealed inside a high purity
aluminum oxide ceramic body. Lead wires are shear force
resistant and assure proper connection to extension leads
and cables.
Models
Description
Tolerance
IEC 60751
Order No.
1Pt100 KN 1515
W0.3
W0.15
W0.1
W0.03
32.206.455
32.206.456
32.206.457
32.206.112
1Pt100 KN 1515 G
W0.3
W0.15
W0.1
32.206.901
32.206.902
32.206.903
Response time
Self Heating
0°C (K/mW) Water current Air stream
V=3m/s
V=0.4m/s
Dimensions
mm
L
D
d
l
+2
15- 0
1.5±0.15
0.20±0.01
10.0±0.5
+2
15- 0
1.5±0.15
0.27±0.01
10.0±0.5
t 0.5
t 0.9
t 0.5
t 0.9
0.08
0.2
0.4
5.0
15.7
0.08
0.2
0.4
5.0
15.7
Technical Specification
100 Ohm @ 0 °C
Temperature range:
W0.3 (Class B) = -196 to +660 °C
W0.15 (Class A) = -196 to +600 °C
(Heraeus exceeds IEC 60751: -100 to +450 °C)
Insulation resistance
> 100 MOhm @ 25 °C
after assembly:
Measuring current:
Tolerance class:
W0.1 (Class 1/3 B) = -100 to +350 °C
W0.03 (Class 1/10 B) = -50 to +300 ºC
(Special HST Class proportional to W0.3)
Temperature
coefficient:
Tc = 3850 ppm/K
Leads:
Palladium-gold alloy
The measuring point is located at 8 mm from the end of the sensor body
1 mA
- According to IEC 60751:2008
- Other standards and narrower
tolerances are available on request
Temperature stability: Excellent long-term stability
Also available:
- Platinum-gold alloy
- Different temperature coefficients
(3916 ppm/K - old JIS)
- Extension leads
- Two separated coils can be embedded
in one ceramic body
Heraeus Sensor Technology USA
1901 Route 130
North Brunswick, NJ 08902
Phone 732-940-4400
Fax 732-940-4445
Email [email protected]
www.hst-us.com
Status: HSTUSA 11/09
Status 01/2009. Technical modifications reserved.
Nominal resistance: