ETC 32200018

Platinum Resistance Temperature Detector
L 622 DBC
L series PRTDs, type L 622 DBC are designed for large volume applications where longterm stability, interchange ability
and accuracy over a large temperature range are vital. The high resistance value of 1000 Ohm generates a high signal
yield. Typical applications are Automotive, White goods, HVAC, Energy management, Medical and Industrial equipment.
Nominal
Resistance R0
Tolerance
DIN EN 60751
1996-07
Tolerance
DIN EN 60751
2009-05
Order Number
Plastic Box
Lead Length KL
1000 Ohm at 0°C
Class B
F 0.3
32 200 018
160mm
1000 Ohm at 0°C
Class B
F 0.3
32 200 023
250mm
The measuring point for the nominal resistance is situated on the connections of the sensor body
Specification
DIN EN 60751
Temperature range
-40°C to +160°C
Tolerance Class B: -40°C up to +160°C
Temperature coefficient
TC = 3850 ppm/K
Leads
Cord, silicon isolated AWG 30
Wire lengths (KL)
70 to 500mm, customer connection engraved
Long- term stability
max. R0-Drift 0.04 % after 1500 h at 160°C
Vibration resistance
at least 40g acceleration at 10 to 2000 Hz,
depends on installation
Shock resistance
at least 100g acceleration with 8ms
half sine wave, depends on installation
Environmental conditions
max. 80% rel. humidity; durability against
non-conductive media
Self heating
0.4 K/mW at 0°C
Response time
water current (v= 0.4m/s):
air stream(v= 2m/s):
t0,5 = 0.20s
t0,9 = 0.30s
t0,5 = 3.4s
t0,9 = 11.0s
Measuring current
1000: 0.1 to 0.3mA
(self heating has to be considered)
Note
Other tolerances, values of resistance and
wire lengths are available on request.
We reserve the right to make alterations and technical data printed. All technical data serves as a guideline and does not guarantee
particular properties to any products.
Heraeus Sensor Technology USA
1901 Route 130
North Brunswick, NJ 08902
Phone 732-940-4400
Fax 732-940-4445
Email [email protected]
www.hst-us.com
Name of document: 30910010 Index A
Status: 06/2010