Data Sheet DC Electronic Loads 8500 series 2400W Versatile & Economical DC Electronic Loads 600 W - 1200 W The 8500 family offers 10 mode ls with a wide range of ratings The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating a variety of DC power sources. Their wide operating ranges of up to 500 V and 240 A, flexible operating modes and excellent measurement accuracy make the 8500 series well suited for characterizing DC Power supplies, DC-DC Converters, batteries, fuel cells and solar cells. The loads can operate in CC, CV, CR or CP mode while voltage/current or resistance/power values are measured and displayed in real time. Load terminals are isolated and floating. Extensive protection, including over temperature, over power, over voltage, over current and reverse polarity will help protect your valuable prototype. The DC loads are easy to use. All parameters can be set quickly and precisely from the front panel, or programmed via RS232 or USB interfaces. Model# Power Ope rating Voltage Rated C urrent 8500 300 W 0.1 - 120 V 30 A 8502 300 W 0.1 - 500 V 15 A 8510 600 W 0.1 - 120 V 120 A 8512 600 W 0.1 - 500 V 30 A 8514 1200 W 0.1 - 120 V 240 A 8518 1200 W 0.1 - 60 V 240 A 8520 2400 W 0.1 - 120 V 240 A 8522 2400 W 0.1 - 500 V 120 A 8524 5000 W 0.1 - 60 V 240 A 8526 5000 W 0.1 - 500 V 120 A When selecting a DC load, it is important to consider not only voltage and current requirements, but also power ratings. The power used when testing must fall within the hatched region for the appropriate DC load. Inpu t voltage Rated power I npu t cu rrent Technical data subject to change © B&K Precision Corp. 2012 300 W w w w.bk prec ision.c om Tel.: 714.921.9095 Some applications may require high voltage/low current and low voltage/high current which a single load may not be able to handle. B&K Precision’s broad range of DC loads will allow you to select the optimal model for your requirements. DC Electronic Loads Models 8500, 8502, 8510, 8512, 8514, 8518, 8520, 8522, 8524, 8526 Features ■ Constant current (CC), resistance (CR), voltage (CV) and power (CP) operation ■ Wide voltage and current range, 0 to 500 V, 0 to 240 A (5000 W max) ■ Low minimum operating voltage of < 0.1 V and minimum input resistance of 5 mΩ (model 8518) allowing the load to sink high current at low voltages, required for fuel and solar cell applications ■ Selected models operate up to 500 V, suitable for high voltage applications ■ Built-in ■ Short transient generator circuit test ■ Built-in high resolution (0.1 mA/1 mV) voltage Applications: and current measurement (models 8500 & ■ DC 8502) ■ Characterization ■ Bright, easy to read display (VFD technology) ■ Over-Current/Over-Voltage/Over-Power/Over- power supply testing the ampere*hour (A*hr) characteristic of a battery. Temperature Protection to TTL, USB to TTL serial ■ Fuel converter cables and application software ■ High ■ RS232 of rechargeable batteries. A battery test mode is provided that will measure and solar cell test voltage applications included ■ List mode operation for increased throughput. ■ Battery testing mode to provide A*hr rating of battery (ending voltage level is adjustable) ■ Flexible triggering: Create trigger events by front panel keystroke, back panel TTL signal, or software. ■ Remote voltage sensing to compensate for the effect of voltage drop in wires. ■ Store 25 instrument setups ■ Thermostatically-controlled fans allow operation in quiet environments with minimal disruption. ■ All Low voltage operation The 8500 series can operate well below 1 V which is important for low voltage application such as fuel cell and solar cell testing. All models can regulate (provide a stable input) down to 0.1 V. Model 8518, due to its particularly low input resistance, can operate at full scale current of 240 A at 1.2 V (see image) models are rack mountable. Compact 300 W and 600 W models for bench use Typical minimum operating voltage at full scale current: 8500 1.05 V 2 8502 3V 8510 1.8 V 8512 3V 8514 1.92 V 8518 1.2 V 8520 10.8 V 8522 3.6 V 8524 1.56 V 8526 1.8 V w w w.bk prec ision.c om DC Electronic Loads Models 8500, 8502, 8510, 8512, 8514, 8518, 8520, 8522, 8524, 8526 ▲ Front panel operation, rear panel The numeric keys and rotary knob provide a convenient interface for setting the operating mode and desired current/voltage/resistance levels quickly and precisely. Voltage and current can be set to a maximum resolution of 1 mV and 0.1 mA respectively (models 8500 and 8502 only). Up to 25 different instrument setups can be stored and recalled from internal memory. 1 3 2 4 1 ) High re solution, easy to read display Displays set values and measured values. Current/voltage and power/resistance displays can be toggled. Display resolution for current and voltage is user-selectable. Maximum resolution for model 8500 and 8502 is 1 mV/ 0.1 mA. 3) Numeric keypad Conveniently enter set values directly and access secondary functions. 2) Convenie nt d ata e ntry Rotary knob for quick analog-style control. Turn to adjust a setting value. Press to toggle measurement display mode. 5) Front panel load terminals Connect to device under test. 4) Function keys Activate current, voltage, power, or resistance modes and scroll through menus and options. Hex-head sc rew t erminals Hex-head screw terminals are used for models 8518 and 8520 – 8526 to connect wires. 1 ▲ Rear view 1) Air vents Temperature-controlled fan expels air through these vents to keep the temperature constant inside the system. 3 ) Interface connection Serial interface connector for RS232 or USB communication. 2) 4) Voltage switch Line voltage selection switch (110 VAC or 220 VAC). Trigge r and remote sensing terminal block Connect sensing lines to this terminal to compensate for voltage drops due to load wire resistance. This terminal block also contains the two connections for the remote TTL trigger input signal. 5 3 3 2 4 w w w.bk prec ision.c om DC Electronic Loads Models 8500, 8502, 8510, 8512, 8514, 8518, 8520, 8522, 8524, 8526 ▲ Flexible operating modes C C, CR, C V and CP mod e In Constant Current (CC) mode, the load will sink a current according to the programmed current value regardless of the input voltage. (CC) mode can be used for load regulation testing of DC power supplies or for characterizing the discharge profile of a battery. Constant Power (CP) mode simulates a load whose power consumption is independent of the applied voltage. Constant Power (CP) mode is useful for battery testing and simulating a realistic discharge curve. In Constant Voltage (CV) mode, the load will attempt to sink enough current to control the source voltage to the programmed value. This mode is suitable for testing battery chargers. In Constant Resistance (CR) mode, the load will sink a current linearly proportional to the input voltage in accordance with the programmed resistance. Unlike conventional resistors, the load resistance stays constant regardless of the power level. Transient g enerator The 8500 series offers a variable frequency generator which can be used in all operating modes. The DC load will toggle between 2 preset levels at a frequency between 0.1 Hz to 1 kHz, either continuously or controlled by a trigger. Model 8500 Trigg ere d ope ration Triggering is used to allow synchronization of the DC Load's behavior with other events. You can generate a trigger event by front panel keystroke, by applying an external TTL signal to the back panel terminal or by sending a commands over the serial bus. The trigger can be used in pulse mode, transient mode, list mode and works in CC, CR, CV and CP modes. ▲ Remote control & application software The DC loads can be remotely controlled from any PC with USB or RS232 interface, allowing the user to fully program and monitor all parameters. RS232 to TTL and USB to TTL serial converter cables are included. For users wanting to write their own custom software, a set of example programs are available for download on the B&K Precision website. List Mode A list of command sequences can be stored in non-volatile memory and executed independently of a computer. Execution in list mode greatly reduces command processing time and computer interaction during product testing. The command sequence can be entered manually from the front panel or downloaded from a PC via RS232 or USB interface. Application Software The included Application Software supports front panel emulation of the load and includes a battery test application which provides A*hr rating of a battery and adjustable ending voltage levels (safety voltage). Whether you are designing a device with 4 An example of battery discharge characteristics of an AA alkaline battery. Nickel-Metal Hydride or Lithium-Ion batteries, the 8500 series have the capabilities to test their characteristics. w w w.bk prec ision.c om DC Electronic Loads Models 8500, 8502, 8510, 8512, 8514, 8518, 8520, 8522, 8524, 8526 Specifications ▲ Models 8500 & 8502 (300 W) Parameter Voltage Current Power Input rating Parameter 8500 8502 0 to 120 V 1 mA to 30 A 0 to 500 V 1 mA to 15 A 300 W Range 8500 CV Mode Regulation CC Mode Regulation Accuracy 0.1-18 V 0.1 – 120 V 0–3A 0 – 30 A 0–3A 0 – 30 A Current Measurement Voltage Measurement Resolution 8502 ±(0.05%+0.02% FS) ±(0.05%+0.025% FS) ±(0.1%+0.1% FS) ±(0.2%+0.15% FS) ±(0.1% + 0.1% FS) 8500: ±(0.2%+0.15% FS) 8502: ±(0.2%+0.3% FS) ±(0.02% + 0.02% FS) ±(0.02% + 0.025% FS) 0.1 – 500 V 0–3A 0 – 15 A 0–3A 0 – 15 A 0-18 V 0-120 V 0 – 500 V 1 mV 10 mV 0.1 mA 1 mA 0.1 mA 1 mA 1 mV 10 mV ▲ Models 8510/8512/8514/8518 (600 W & 1200 W) Parameter Input rating 8510 Voltage Current Power 8512 0 – 120 V 0 – 120 A 0 – 500 V 0 – 30 A 600 W Parameter CV Mode Regulation CC Mode Regulation Current Measurement 0-12 A 0-12 A Voltage Measurement 8512 8518 0 – 60 V 0 – 240 A 1200 W Range 8510 8514 0 – 120 V 0 – 240 A Accuracy 8514 0.1-18 V 0.1 V to Vmax 0-3 A 0 – max Current 0-3 A 0 – max. Current 0 – 18 V Resolution 8518 ±(0.05%+0.02% FS) ±(0.05%+0.025% FS) ±(0.1%+0.1% FS) ±(0.2%+0.15% FS) ±(0.1% + 0.1% FS) ±(0.2%+0.15% FS) 8510/8514: (0.02% + 0.025% FS) 8512/8518: (0.02% + 0.02% FS) ±(0.02% + 0.025% FS) 0-24 A 0-24 A 0 - Vmax 1 mV 10 mV 1 mA 10 mA 1 mA 10 mA 1 mV 10 mV ▲ Models 8520/8522/8524/8526 (2400 W & 5000 W) Parameter Input rating Voltage Current Power 8522 8524 0 – 500 V 0 – 120 A 0 – 60 V 0 – 240 A 2400 W Parameter 0-24 A 0-12 A 8522 0.1-18 V 0.1 V to Vmax 0-12 A 0-24 A 0 – max Current 0-3 A 0-24 A 0 – max. Current 0 – 18 V 0 - Vmax 5 Accuracy 8524 Voltage Measurement 8526 0 – 500 V 0 – 120 A 5000 W Range 8520 CV Mode Regulation CC Mode Regulation Current Measurement 8520 0 – 120 V 0 – 240 A Resolution 8526 0-12 A 0-12 A ±(0.05%+0.02% FS) ±(0.05%+0.025% FS) ±(0.1%+0.1% FS) ±(0.2%+0.15% FS) ±(0.1% + 0.1% FS) ±(0.2%+0.15% FS) 8522/8526: (0.02% + 0.02% FS) 8520/8524: (0.02% + 0.025% FS) ±(0.02% + 0.025%FS) 1 mV 10 mV 1 mA 10 mA 1 mA 10 mA 1 mV 10 mV w w w.bk prec ision.c om DC Electronic Loads Models 8500, 8502, 8510, 8512, 8514, 8518, 8520, 8522, 8524, 8526 ▲ All 8500 DC load models Common characterist ics Parameter CR Mode Regulation (Input current ≥ FS 10% Input Voltage≥ FS 10%) CW Mode Regulation (Input current ≥ FS 10% Input Voltage≥ FS 10%) Power Measurement (Input current ≥ FS 10% Input Voltage ≥ FS 10%) Battery testing function Accuracy Resolution 0.1 -10 Ω 10-99 Ω 100-999 Ω 1K-4 KΩ 0-100 W 100 W – max Power Range ±(1%+0.3% FS) ±(1%+0.3% FS) ±(1%+0.3% FS) ±(1%+0.8% FS) ±(1%+0.1% FS) ±(1%+0.1% FS) 0.001 Ω 0.01 Ω 0. 1 Ω 1Ω 1 mW 100 mW 0-100 W 100-max Power ±(1%+0.1% FS) ±(1%+0.1% FS) 1 mW 100 mW Input = 0.1 V – 120 V Max measurement capacity = 999 A*hr Resolution = 10 mA Timer range = 1-60000 sec Range of Frequency 0.1 Hz-1 kHz Frequency error rate 0.5% Transition Mode Mechanical specifi cati ons Model number 8500 8502 8510 8512 8514 8518 8520 8522 8524 8526 6 v012312 Dimensions (W x H x D) 215 mm×88 mm×355 mm (8.46 in x 3.46 in x 14 in) 215 mm×88 mm×355 mm (8.46 in x 3.46 in x 14 in) 429 mm×88 mm×355 mm (16.9 in x 3.46 in x 14 in) 429 mm×88 mm×355 mm (16.9 in x 3.46 in x 14 in) 429 mm×88 mm×355 mm (16.9 in x 3.46 in x 14 in) 429 mm×88 mm×355 mm (16.9 in x 3.46 in x 14 in) 444 mm×180 mm×539 mm (17.48 in x 7.09 in x 21.22 in) 444 mm×180 mm×539 mm (17.48 in x 7.09 in x 21.22 in) 444 mm×357 mm×539 mm (17.48 in x 14.06 in x 21.22 in) 444 mm×357 mm×539 mm (17.48 in x 14.06 in x 21.22 in) Weight 5.2 kg (11.5 lbs) 5.2 kg (11.5 lbs) 14 kg (31 lbs) 14 kg (31 lbs) 14 kg (31 lbs) 14 kg (31 lbs) 30 kg (66 lbs) 30 kg (66 lbs) 67 kg (148 lbs) 67 kg (148 lbs) One Year Warranty Accessories Supplied: Power cord, user manual, installation CD with application software, RS232 to TTL serial converter cable IT-E131, USB to TTL serial converter cable IT-E132 Optional: Rack mount kit IT-E151 w w w.bk prec ision.c om