LABORATORY CW Series 800-2500VA PROGRAMMABLE AC POWER SERIES Features • • • • • Three phase operation High frequency output Advance measurement capability (CWP only) Wide AC input range Excellent output stability Product Overview Manual CW Features and Benefits The Continuous Wave (CW) series of AC power sources provides clean single phase power at an impressive price/performance ratio. These compact switch mode sources come in two series, manual (CW-M) or programmable (CW-P) with standard IEEE-488.2 and RS232 control. Both series have three power levels, 800VA, 1250VA and 2500VA. The 800 and 1250VA models are 2RU high and allow the unit under test to be connected to the front or rear panel. The 2500VA model is 3RU high with rear panel output connections. All models can be operated in a bench-top or rack-mount configuration. The manual series front panel knobs (10 turn potentiometers) allow quick adjustment of voltage, current and frequency settings. Frequency and voltage can be programmed remotely using a 0-5V analog signal. LED’s indicate: output-on, voltage or current mode operation, fault and slave modes. Models can also be paralleled in the field or configured for three phase operation using factory supplied optional cables. Current shutdown or fold-back modes can be selected from rear panel switch. Programmable CW Features and Benefits The front panels have two bright four digit, seven segment displays. Power Factors Corrected (PFC) universal input voltage allows maximum to be delivered from an AC outlet without user selecting the range. Fully rated current is delivered for either output voltage range of 135VAC or 270VAC over a standard frequency range of 45-500Hz. Custom output voltage are available (consult Powerbox for details). Both series can be operated in parallel or three phase configurations. A separate output on/off switch controls power to the load. Remote voltage sense is standard. Transformer coupled output is protected against over-voltage and over-current. The unit is also protected against over-temperature conditions. A two-speed fan results in quieter operation at lower power levels. All models are CE marked. Product Applications The Continuous Wave is designed for testing single or poly-phase electronics. The CW is well suited for applications requiring a cost-effective low profile AC source. APPLICATION INCLUDE: • Testing for real world sine wave power conditions • 400Hz testing for avionics equipment (50/60Hz margin testing) • Ballast testing (Components testing) • Power supply testing for AC to DC converters 496 Front panel encoder knobs allow programming of voltage, current and frequency settings. Programmed or measured values can be viewed on the two LED displays through push button selection. Menu push buttons enable setting system configuration including parallel or three phase operations. This menu also allows setting current shutdown of fold-back modes. Remote IEEE-488.2 and RS232 control interfaces are standard. LEDs indicate high and low range output voltage, measure a program mode, voltage a current mode generation and output on. Also indicate menu/status, remote control, lockout and fault conditions. Digital Signal Processing (DSP) based measurements include voltage, current (amperes, peak amperes, crest factors), power (watts, VA and power factor) and frequency. LABORATORY CW Series 800-2500VA PROGRAMMABLE AC POWER SERIES CW SPECIFICATIONS MANUAL (M) PROGRAMMABLE (P) GENERAL CE mark REGULATORY COMPLIANCE DIMENSIONS CW 801 and CW 1251 2RU 89mm (H) x 483mm (W) x 524mm (D) CW 2501 3RU 133mm (H) x 483mm (W) x 524mm (D) WEIGHT CW 801 22kg CW 1251 24kg CW 2501 39kg SHIPPING WEIGHT CW 801 25kg CW 1251 28kg CW 2501 43kg ENVIRONMENTAL Dual speed fan with side air intake, exhaust to rear Cooling Operating Temperature 0 to 40 OC Storage Temperature -40OC to +70 OC O Humidity 0 to 85% at 25 C de-rate to 50% at 40 OC (non condensing) Altitude Operating full power available up to 6,000 feet, non operating to 40,000 feet ORDERING INFORMATION MODEL NUMBER OUTPUT (SINGLE PHASE) MAXIMUM POWER INPUT (SINGLE PHASE) MAXIMUM CURRENT 135V 270V VOLTAGE (47-63HZ) CW-Manual CW 801M 800VA 6.0A 3.0A 90 to 264VAC CW 1251M 1250VA 9.4A 4.7A 103 to 264VAC CW 2501M 2500VA 18.6A 9.3A 180 to 264VAC CW 801P 800VA 6.0A 3.0A 90 to 264VAC CW 1251P 1250VA 9.4A 4.7A 103 to 264VAC CW 2501P 2500VA 18.6A 9.3A 180 to 264VAC CW-Programmable Options and Accessories H: Expanded frequency range 45 to 1000Hz (CW-P only) L: Locking shafts (front panel potentiometers) (CW-M only) S: Sync In/Out (clock/lock) (standard on CW-P) V: Extended voltage range 0-155V, 0-310V (CW-P only) RACK SLIDE KIT Part No. K16570-01 MULTI-UNIT CABLE Part No. 890-497-40 Required for parallel and paralled polyphase CW-M and CW-P systems. DIGITAL EXPANSION CABLE Part No. 890-499-00 (CW-P only) Required for parallel and paralled polyphase CW-P systems. Your dependable power partner – www.powerbox.com.au 499 LABORATORY CW Series 800-2500VA PROGRAMMABLE AC POWER SERIES CW SPECIFICATIONS MANUALS (M) PROGAMMABLE (P) Peak Current*Range CW 801 0 to 25A CW 1251 0 to 35A CW 2501 0 to 70A Accuracy +/-2% of range Resolution FREQUENCY Range Accuracy 0.1A 45 to 500Hz (45-1000Hz optional on programmable unit only ) +/-0.5% of reading +/-0.02% of value Resolution of display 0.1Hz POWER* Range CW 801 0 to 800W CW 1251 0 to 1250W CW 2501 0 to 2500W Accuracy +/-2% of range for linear loads Resolution 1W APPARENT POWER* Range CW 801 0 to 800 VA CW 1251 0 to 1250 VA CW 2501 0 to 2500 VA Accuracy +/- 2% of range for linear loads Resolution 1 VA POWER FACTORS* Range 0 to 1 Accuracy +/- 4 % of range for linear Resolution 0.01 CREST FACTORS* Range 0 to 3.5 Accuracy +/-5% of range Resolution 0.01 FRONT PANEL DISPLAYS & INDICATORS Menu/ Status Voltage Current/ Frequency Green LED for output on, V mode, I mode, slave Red LED for Fault Green LED’s for remote and lockout, voltage mode, current mode, red LED for fault Enter/escape buttons are present for programming 4 digit display, green LED (volts) 4 digit display green LED (volts, watts, VA, PF, OVP) 4 digit display, green LED (amperes) 4 digit display green LED (amps, Hz, Pk amps, CF, I limit) Program/Measure Green LED (amps, HZ, I limit) V Range High/Low Green LED INPUT VOLTAGE AND FREQUENCY CW 801 90 to 264VAC, 47 to 63Hz, single-phase CW 1251 103 to 264VAC, 47 to 63Hz, single-phase CW 2501 180 to 264VAC, 47 to 63Hz, single-phase CURRENT CW 801 13 ARMS max CW 1251 18.5 ARMS max CW 2501 19.5 ARMS max Power Factor Efficiency > 0.99 typical at full load nominal line > 73% typical at full load Note: In a parallel system, the current/power displayed in the master unit is the sum of all units in the system. 498 LABORATORY CW Series 800-2500VA PROGRAMMABLE AC POWER SERIES CW SPECIFICATION MANUAL (M) PROGRAMMABLE (P) OUTPUT POWER CW 801 800VA CW 1251 1250VA CW 2501 2500VA Power factor of load 0 lag to 0 lead Phase All models single phase output VOLTAGE Ranges Accuracy 0-135VRMS or 0 to 275VRMS, user selectable (consult factory for custom output voltages) Resolution 0.1VRMS Total harmonic distortion AC noise level Amplitude stability +/-0.1% of range < 100Hz, +/-0.2% of range,> 100Hz (>5 VAC out) +/-1% of range (> 5VAC out) 0.25% typical < 100Hz add 0.5%/100Hz above 100Hz < 50 mVRMS typical for CW801 & CW1251, 100 mVRMS typical for CW2501 +/-0.1% of full scale over 8 hours at constant line, load and +/-0.05% of full scale over 8 hours at constant line, load and temperature after 15 minute warm-up typical temperature after 15 minutes warm-up typical Load regulation +/-0.1% of full scale voltage for a full resistive load to no load (<10 mVRMS typical, measured at point of sense) Line regulation +/-0.1% of full scale voltage for a +/-10% line change from nominal line voltage (<5 mVRMS typical, measured at point of sense) Remote voltage sense Compensation for up to 5 VRMS total lead voltage drop CURRENT CW 801 6.0 ARMS in 135VAC range or 3.0 ARMS in 270 VAC range CW 1251 9.4 ARMS in 135VAC range or 4.7 ARMS in 270VAC range CW 2501 18.6 ARMS in 135VAC range or 9.3 ARMS in 270VAC range Accuracy Resolution FREQUENCY Range Accuracy Resolution +/-0.5% typical +/-0.6% max 0.1 ARMS 0.01 ARMS 45 to 500Hz(45 to 1000Hz optional on programmable unit only) +/-0.5% typical +/-0.02% max 0.1Hz 0.1Hz, 0.01Hz for remote programming PHASE ANGLE -359 to +359 degrees. Positive phase indicates time lag from reference Range Accuracy Within 100 microseconds of equivalent angle Resolution 1 degree MEASUREMENT Voltage range Accuracy 0-270 VRMS +/-1% of full range for voltage (>5VAC out), measured at point of sense Resolution +/-0.1% of range < 100Hz, +/-0.2% of range >100Hz, measured at point of sense (> 5VAC out) 0.1 VRMS Current* Range CW 801 0 to 6.0 ARMS CW 125I 0 to 9.4ARMS CW 2501 Accuracy Resolution 0 to 18.6ARMS +/-2% of range for linear loads with current 0.2A for 800VA & 1200VA, 0.4A for 2500VA +/-0.6% of range for linear loads with current 0.2A for 800VA & 1200VA, 0.4A for 2500VA 0.1ARMS 0.01 ARMS Note: In a parallel system, the current/power displayed in the master unit is the sum of all units in the system. Your dependable power partner – www.powerbox.com.au 497 LABORATORY CW Series 800-2500VA PROGRAMMABLE AC POWER SERIES Technical Illustrations CW MANUAL CW PROGRAMMABLE 500