LUGUANG 455C54

455C54
Ceramic Discriminator
1. APPLICATION
This specification is applied to ceramic discriminator : 455C54
used for quadrature detection with IC : TA31142F (TOSHIBA )
2. SPECIFICATION No.: QJ/A5•25•0512
MODEL NAME
Part Name
Customer’s Part No.
Customer’s Draving No.
55C54
3. DIMENSIONS : ( mm )
Material
List
Case
Polybutenetelephthalate
(mixture of glass fiber)
Terminal
Phosphor bronze Ag Clad
Base Sealing
4.
Epoxy
MAXIMUM RATINGS
4.1
Withstanding Voltage
(Between each terminal)
4.2 Insulation Resistance
(Between each terminal)
4.3 Input signal level
4.4 Operating Temperature Range
4.5 Storage Temperature Range
:
D.C. 5OV. 1 minute
:
100 MΩ min. at D.C. 100V
:
:
:
5dB (50Ω Termination )
- 20℃ to + 80 ℃
25 ±5℃
SHENZHEN LUGUANG ELECTRONIC TECHNOLOGY CO.,LTD.
resin
455C54
Ceramic Discriminator
5. ELECTRICAL CHARACTERISTICS
5-1
5-2
5-3
5-4
( 0℃ to + 40 ℃ )
Item
Requirements
Receiver Audio 3dB Bandwitdth (from 455KHz)
Receiver Audio Output Voltage (at 455KHz)
Distortion (at 455 KHz)
Withstanding Voltage
±4.0 KHz min.
40 ± 20 mV
3.0% max.
50V D.C. for 1 minute
5-5 Test Method
Input signal Condition Input level
: 80dB
Frequency Deviation : ±4.0KHz
Modulation Frequency : 1 KHz
1) Recoverd Audio
Input the above signal and sweep the carrier frequency
3dB Bandwidth
around 455 KHz and find out the maximum audio
output frequency. Then sweep the carrier frequency
again and find two frequencies which are observed
-3dB attenuation points from the maximum point .
Higher frequency point is called (f1) and lower called
(f2), (f1-455KHz)is defined as upper 3dB bandwidth
and (455Khz-f2) defined as lower 3 dB bandwidth.
2)
Receiver Audio
Output Voltage
3) Distortion
Receiver audio output voltage shall be measured
when carrier frequency is adjusted to 455KHz.
Carrier frequency is adjusted to 455Khz. And
then ,distortion shall be measured with 1 kHz
modulation frequency.
6. PRYSICAL AND ENVIRONMENTAL CHARACTERISTICS
Test Item
6-1
Lead Strength
Lead Pulling
Lead Bending
6-2
Vibration
Condition of Test
Requirements
After force 1.0Kg is applied to each lead in axial direction.
No
mechanical
filter shall be measured.
When force of 0.5Kg is applied to each lead in axial damage
and
the
measured values shall
。
direction the lead shall be folded up to 90 from the axial meet item 5.
direction and folded back to the axial direction .
Filter shall be measured after being applied vibration of
amplitude of 1.5mm with 600 to 3,300 r.p.m. band of
vibration frequency to each of 3 perpendicular directions
for 2 hour .
SHENZHEN LUGUANG ELECTRONIC TECHNOLOGY CO.,LTD.
455C54
Ceramic Discriminator
6-3
Random Drop
6-4
Temperature Filter shall be measured within
Characteristics temperature range.
6-5
Humidity
6-6
Resistance to
Soldering Heat
Filter shall be measured after 3 times random dropping
from the height of 30cm on concrete floor
-20 ℃ to +80 ℃
Filter shall be measured after being placed in a chamber
with 90 to 95% R. H. at 40±2℃ for 100 hours and then
being placed in natural condition for 2 hour.
The measured values
shall meet Table 1.
Lead terminals are immersed up to 1.5mm from filter’s
body in soldering bath of 260±5℃ for 5±0.5 seconds and
then filter shall be measured after being placed in natural
condition for 2 hour.
6-7 Life Test(High Filter shall be measured after being placed in chamber with
Temperature) 80℃ for 100 hours and then being placed in natural
condition for 2 hour.
6-8
Life Test
Filter shall be measured after being placed in a chamber
(Low
with -20℃ for 100 hours and then being placed in natural
Temperature) condition for 2 hours.
6-9
Thermal Shock After temperature cycling of -20℃(30 minutes)to +80℃
(30 minutes)was performed 5 times. Filter shall be
returned to room temperature. And filter shall be measured
after being placed in natural condition for 2 hours.
Item
Receiver Audio 3dB Bandwidth
(from 455KHz)
Receiver Audio Output Voltage
(at 455KHz)
Distortion
( at 455KHz)
Requrements
±4.0 KHz min.
40±20 mV
4.0 % max.
Withstanding Voltage
50V D. C. for 1 minute.