smt POWer inductors Flat Coils - PG0426NL Series Height: 3.2mm Max Footprint: 7.5mm x 7.0mm Max Current Rating: 60Apk Inductance Range: 0.1µH to 1.5µH High temperature core material, no thermal aging below 150°C Electrical Specifications @ 25°C — Operating Temperature -40°C to +130°C 1 Part 6 Number Inductance DCR (mW) @0A d c TYP MAX (mH ±20%) PG0426.101NL PG0426.151NL PG0426.201NL PG0426.221NL PG0426.331NL PG0426.471NL PG0426.681NL PG0426.821NL PG0426.102NL PG0426.152NL 0.10 0.15 0.20 0.22 0.33 0.47 0.68 0.82 1.00 1.50 1.3 2.0 2.0 2.0 3.2 3.2 5.2 7.8 7.8 11.5 Saturation 2 Current Isat (A) Heating 3 Current I d c (A) Core Loss 4 Factor K2 60 57 46 40 34 26 25 24 22 18 34.5 26.0 26.0 26.0 20.0 20.0 15.5 13.0 13.0 9.0 44.4 40.0 53.3 58.6 62.8 89.4 100.6 99.3 121.1 153.6 1.5 2.2 2.2 2.2 3.4 3.4 5.4 8.0 8.0 11.8 Schematic Mechanical 3.0(.118)REF. � 3.0(.118) REF. 8.5(.335) REF. ���� ���� Weight....................... 0.6 grams Tape & Reel................1400/reel Dimensions: Inches mm Unless otherwise specified, all tolerances are ± .010 0,25 ���� ���� ������������������ � ����� ����� ������������� ������������ ���������������������� USA 858 674 8100 • Germany 49 7032 7806 0 • Singapore 65 6287 8998 • Shanghai 86 21 54643211 / 2 • China 86 755 33966678 • Taiwan 886 3 4641811 www.pulseeng.com 55 SPM2007 (11/08) smt POWer inductors Flat Coils - PG0426NL Series Notes from Tables 1. The temperature of the component (ambient plus temperature rise) must be within the standard operating temperature range. 2. The saturation current, Isat, is the current at which the component inductance drops by 30% (typical) at an ambient temperature of 25°C. This current is determined by placing the component in the specified ambient environment and applying a short duration pulse current (to eliminate self-heating effects) to the component. 3. The heating current, Idc, is the DC current required to raise the component temperature by approximately 40°C. The heating current is determined by mounting the component on a typical PCB and applying current for 30 minutes. The temperature is measured by placing the thermocouple on top of the unit under test. Take note that the component’s performance varies depending on the system condition. It is suggested that the component be tested at the system level, to verify the temperature rise of the component during system operation. 4. Core loss approximation is based on published core data: Core Loss = K1 * (f)1.33 * (K2DI)2.51 Where: Core Loss = in Watts K1= 1.4E-11 f = switching frequency in kHz K1 & K2 = core loss factors DI = delta I across the component in Ampere K2DI = one half of the peak to peak flux density across the component in Gauss 5. Unless otherwise specified, all testing is made at 100kHz, 0.1VAC. 6. Optional Tape & Reel packaging can be ordered by adding a “T” suffix to the part number (i.e. PG0426.101NL becomes PG0426.101NLT). Pulse complies to industry standard tape and reel specification EIA481. ������������������������������������� �������������������������������������� ���� ��� ������������ ��� ������ ���� ������ ������������� ��� ������������ ��� ��� ��� ������������ ��� ���� ������ ������ ���� ������ ���� ���� ���� ������������ ��� ���� ������������ ��� ���� ��� � � � �� �� �� �� �� �� �� � �� � �� �� �� �� ��� �� ��� ��� ��� ����������� ��� ��� ��� ��� ��� ��������������� ���������������� ������������������������������������������������ ������������������������� ��������������� ��� ��� ������������ ������������ ������������ ��� ������������ ������������ ������������ ������������ ������������ �� ������������ �� �� �� � � � �� �� �� �� ����������� �� �� �� �� USA 858 674 8100 • Germany 49 7032 7806 0 • Singapore 65 6287 8998 • Shanghai 86 21 54643211 / 2 • China 86 755 33966678 • Taiwan 886 3 4641811 www.pulseeng.com 56 SPM2007 (11/08) ����