PG0277 - Product finder

SMT POWER INDUCTORS
Flat Coils - PG0277NL Series
Height: 6.5mm Max
Footprint: 14.5mm x 13.2mm Max
Current Rating: up to 35A
Inductance Range: 0.38µH to 2.65µH
RoHS compliant
Self-leaded version of PG0077 series
Electrical Specifications @ 25°C — Operating Temperature -40°C to +130°C 1
2
MAX
Inductance
@0A DC
(μH ±20%)
Saturation 4
Current
Isat (A)
Heating 5
Current I DC
(A)
Core Loss 6
Factor
K2
0.75
0.80
0.45
48
35
33.5
31
1.20
1.30
0.80
38
31
42.5
1.32
26
2.00
2.10
1.40
28
26
57.8
1.90
21
2.80
2.90
2.00
24
21
67.6
2.65
17
4.10
4.20
2.80
20
17
80.1
Part 8,9
Number
Inductance
@Irated
(μH TYP)
PG0277.401NL
DCR (mΩ)
Irated 3
(A)
TYP
0.38
35
PG0277.801NL
0.75
PG0277.142NL
PG0277.202NL
PG0277.282NL
Schematic
Mechanical
.256
6,50
MAX
.571
MAX
14,50
.520
13,20
MAX
2x
.161 ± .005
4,10 ± 0,12
PG0277.XXXNL
Date Code
Country of Origin
.193 ± .005
4,90 ± 0,12
.945 ± .012
24,00 ± 0,30
.583 ± .005
14,80 ± 0,12
SUGGESTED PAD LAYOUT
1
2
Weight......................5.5 grams
Tape & Reel ................300/reel
Dimensions: Inches
mm
Unless otherwise specified, all tolerances are ± .010
0,25
.945
24,00
TAPE & REEL LAYOUT
USA 858 674 8100 • UK 44 1483 401 700 • France 33 3 84 35 04 04 • Singapore 65 6287 8998 • Shanghai 86 21 54643211 / 2 • China 86 769 5538070 • Taiwan 886 3 4641811
www.pulseeng.com
63
SPM2006 (2/08)
SMT POWER INDUCTORS
Flat Coils - PG0277NL Series
Notes from Tables
tested at the system level, to verify the temperature rise of the
component during system operation.
6. Core loss approximation is based on published core data:
1. The temperature of the component (ambient plus temperature
rise) must be within the specified operating temperature range.
2. Inductance at Irated is a typical inductance value for the component taken at rated current.
3. The rated current listed is the lower of the saturation current @
25°C or the heating current.
4. The saturation current, ISAT, is the current at which the component inductance drops by 20% (typical) at an ambient temperature of 25°C. This current is determined by placing the component in the specified ambient environment and applying a short
duration pulse current (to eliminate self-heating effects) to the
component.
5. The heating current, IDC, is the DC current required to raise the
component temperature by approximately 40°C. The heating current is determined by mounting the component on a typical PCB
and applying current for 30 minutes. The temperature is measured by placing the thermocouple on top of the unit under test.
Take note that the component’s performance varies depending
on the system condition. It is suggested that the component be
Core Loss = K1 * (f)1.30 * (K2ΔI)2.41
Where: Core Loss = in Watts
K1= 3.50E-10
f = switching frequency in kHz
K1 & K2 = core loss factors
ΔI = delta I across the component in Ampere
ΔI = one half of the peak to peak flux density
K2Δ
across the component in Gauss
7. Unless otherwise specified, all testing is made at
100kHz, 0.1VAC.
8. Optional Tape & Reel packaging can be ordered by adding a "T"
suffix to the part number (i.e. PG0277.401NL becomes
PG0277.401NLT). Pulse complies to industry standard tape and
reel specification EIA481.
Inductance vs Current Characteristics
INDUCTANCE (µH)
3.0
PG0277.282NL
2.5
PG0277.202NL
2.0
1.5
PG0277.142NL
1.0
PG0277.801NL
0.5
PG0277.401NL
59
55
51
47
43
39
35
31
27
23
19
15
11
7
3
0
0.0
DC BIAS (A)
Typical Core Loss vx Peak Flux Density
2.00
1.80
CoreLoss (W)
1.60
400
kHz
1.40
1.20
1.00
0.80
300
kHz
100
kHz
200
kHz
500
kHz
1.0
MHz
0.60
0.40
0.20
0.00
100
200
300
400
600
500
700
800
900
1000
DB (Gauss) where DB = K2DI
USA 858 674 8100 • UK 44 1483 401 700 • France 33 3 84 35 04 04 • Singapore 65 6287 8998 • Shanghai 86 21 54643211 / 2 • China 86 769 5538070 • Taiwan 886 3 4641811
www.pulseeng.com
64