Hartcran House, 231 Kenton Lane, Harrow, Middlesex, HA3 8RP, England Tel: +44 (0) 20 8909 9595, Fax: +44 (0) 20 8909 2233, www.radiometrix.com CTA88 App. board Issue2, 27 July 2012 CTA88 Remote Control Application Boards The CTA88 chip is a simple encoder/decoder for use with ISM/SRD band telecommand modules. It permits a simple, one way wireless link to be established, for simple remote control applications, with a minimum of effort and no customer software input. These TX and RX application boards are designed to allow easy evaluation of the CTA88 device in elementary jobs. They provide a simple 8 channel implementations of remote control, using either LMT/LMR or BiM footprint wireless radio modules. Features 8 bit address and 8 bit data select switches 8 relays to control mains powered devices rated up to 8A, 250VAC/30VDC Visual indication of valid code received and active relays RF module range testing 8 Push buttons for momentary control of relays Momentary, Latched outputs Dynamic relay state changes Setup is simple as Plug-and-Play RF Remote Control Demonstration Figure 1: CTA88 RX application board Kit Contents The CTA88 application kit is supplied with the following contents: 2 CTA88-000-DIL 1 CTA88 (10mW/100mW) Encoder board or 1 CTA88H (500mW) Encoder board 1 CTA88 Decoder board 1 Radiometrix Transmitter module (ordered separately) 1 Radiometrix Receiver module (ordered separately) 1/4-wavelength monopole or helical antennas 8 Jumper Links Figure 2: CTA88 TX application board Additional requirement External power supply or 12V DC power adaptor Radiometrix Ltd CTA88 application board manual page 1 Common features: Interfaces Input/output Power CTA88 mode CTA88 address Radio channel Radio setup RF 8 x 3.81mm pitch 3 pin "Phoenix" two part connectors (JP1 – JP8) 2.1mm DC power connector (JP15) and 2 pin "Phoenix" (JP14). (these inputs are diode "or'ed" together) On/off slide switch (S3) on pcb 3 position jumpers (JP12) 8 position DIP switch (S1) 4 position DIP switch (optional) (S2) 2 pin 0.1" pitch "Molex" serial connection (optional) (JP13) SMA (or optional screw terminal) (CON1) Indicators Power on LED (D10) send/receive LED (D9) 8 x I/O pin state LEDs (D1 – D8) CTA88 Clock 3.58MHz (ceramic resonator) Data rate 1kbit/sec Biphase coded burst Part: Leaded 28 pin, in socket Size TX & RX boards 115 x 86 x 20mm (excluding connectors) (four 3.3mm diameter mounting holes are provided) Operating temp. -20°C to +70°C (some radios may be limited to -10°C to +55°C) (Storage -30°C to +70°C) CT88 TX Application board Inputs Supply 2.5V to 50V (5mA) opto-isolated inputs with manual "test" pushbuttons (SW1 – SW8) LED indicators on all channels Link selectable DC supply (5V aux, 5V main, or unregulated Vin) on each channel. (fit one link only on jumper JP10) Link selecting low power / normal mode (JP11) 6 –15V DC 7 –15V DC for 400-500mW high power variants idle current: 4mA (standard mode) 3µA (low power mode) receive current Depends upon receiver module fitted transmit current Depends upon transmitter module fitted 50mA with LMT2-433-5 fitted Radio modules Radiometrix Ltd any LMT1, LMT2 or LMT3 version transmitter versions of NiM2, BiM1, BiM1H, BiM2G, BiM3B, RDL2(tx). (Fit R32. Idle current increases by 10mA) CTA88 application board manual page 2 TX application board jumpers and DIP switches The TX encoder board has 4 jumpers and 2 DIPswitches. The jumpers are used to select the number of operating modes featured in the board while the 4 way and 8 way DIP switches are used for frequency channels selection and address selection respectively. Figure 3: CTA88 Encoder application board for BiM / LM Transmitter Assumed the board is held "long side horizontal" with the RF and power connectors at the top Jumper. Name Function Position Mode Low current / always JP10 SUPPLY Selects which power supply is fed Left present +5v to the user inputs busbar (Only EVER fit one jumper on this (100mA max, total) (default) header) JP11 LOW POWER JP12 JP13 MODE RADIO SETUP R32 Radiometrix Ltd Middle Main +5v (250mA). In low power mode this rail is only Present during actuation Right Unregulated Vin, via switch and 1A schottky diode Normal Up Selects low power or normal mode Down Normal mode draws 5mA Low power (default) quiescent current: Low power draws 3uA, but if "low power" operation is selected then the coder device and transmitter are only activated when one of the inputs is "active". Therefore only modes 001 and 100 can be used with this option. Selects Operating modes see operating mode section below Radio setup (only for LM series Ground (GND) and the RS232 input radios) to the PGM pin Factory fitted for RDL2 (tx) use. Idle current increases by 10mA CTA88 application board manual page 3 TX application board DIP switches The TX application board features an 8 way (S1) and a 4way (S2) DIP switches. The optional 4 way DIP switch which is used for parallel frequency channel select is only required when our multi channel LM series radios like LMT1 / LMT2 s are used. The 8-way DIP switch is used to set an 8 bit (256 combinations) unit address. CTA88 RX Application board Outputs 8A 240V AC rated change over relay contacts (RLA1 – RLA8) LED indicators on all 8 channels (D1 – D8) Supply 12V (10-15V) receive/idle current (depends upon radio module fitted) 23mA with LMR2-433-5 fitted relay current 25mA per activated channel Radio modules any LMR version receive only versions of NiM2, BiM1, BiM2A, BiM3 (any) CVR1 (5V versions); RDL2 (rx) RX application board jumpers and DIP switches The RX encoder board has 2 jumpers and 2 DIP switches. As with TX board, the jumpers are used to select the number of operating modes featured in the board while the 4 way and 8 way DIP switches are used for frequency channels selection and address selection respectively. Figure 4: CTA88 Decoder application board for BiM / LMR Receiver Assumed the board is held "long side horizontal" with the RF and power connectors at the top Jumper. Name Function Position Mode JP12 MODE Select Operating mode (see operating mode section below) P13 PGM Radio setup (only for LM Ground (left) and the RS232 input series radios) (right) Radiometrix Ltd CTA88 application board manual page 4 RX application board DIP switches The RX application board features a 4 way (S2) and an 8 way (S1) DIP switches. The optional 4 way DIP switch which is used for parallel frequency channel select is only required when our multi channel LM series radios like LMR1 / LMR2 s are used. The 8 way Dip switch is used to set an 8 bit (256) unit address. Operating modes Device operation is set up by a 3 bit word, on the C0-C2 jumpers. This is JP12 on both the TX and the RX boards. C2 C1 C0 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 1 1 1 1 0 1 C2 C1 C0 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 1 1 0 1 1 1 Encoder Transmitter Modes ( 1 = 5V Jumper Link Inserted ) Device is inactive Send single burst, once only (on reset, and on each C0 low/high transition) Send continuously Send single burst on any change of Data input word Send continuously while any Data input pin is high Send a burst on average every 1.75 seconds. A P/N sequence generates a delay of 1 -2.5s between bursts Serial mode (see notes) Transmitter test. Send a constant 250Hz squarewave (C0=H, C1=H, C2=H) Decoder Receiver Modes ( 0 = 0V Jumper Link Removed ) Local test. Data output word equals Address input word Output last data received (150ms timeout) Output last data (3 second timeout: see notes) Hold last data received D0-3 'set' corresponding bit, D4 resets D0, D5 resets D1 .. and so on A '1' on any bit toggles the state of the corresponding output pin Serial (see notes) Link test. Data word outputs most recently received burst address Which modes to use? The CTA88 have a variety of operating modes. These are better understood by relating them to different applications: 1. Wire replacment:. Operate transmitter in mode 010 (continuous: allows the STB output to be used as a 'good link' indicator) and receiver in mode 001. If receiver operates in latched (011) mode then 'chattering' of the output is reduced (at extreme range, or with interferers present), but the link is no longer fail safe Latched mode is also compatible with send on change (011) 2. Momentary push buttons: Transmitter in mode 100 (send while any input is high), receiver in 001. Outputs remain high for as long as the button is held down. This is the mode one would choose to control (for instance) a pan/tilt head (D0= slew left, D1 = slew right, etc) 3. Controlling four lights: Use transmit mode 100 (send while high) or 011 (send on change), with the receiver in mode 100. This gives four outputs (D0-D3), each set by one transmitter input (D0-D3) and reset by another (D4-D7) Radiometrix Ltd CTA88 application board manual page 5 4. Monitoring infrequent events (such as door open/shut): Use transmitter in periodic transmit (101, to keep channel occupancy and power usage low), and receiver on 010 (3 second timeout), 011 (hold last burst) or 110 (serial data output, to a PC or data logging device). In this mode the transmit duty cycle is less than 10% on average, and the variable delay between bursts permits same channel operation of several CTA88 links with minimum transmit collisions 5. Send burst on trigger event: Set transmitter to mode 000 (off) and use C0 line high as a 'strobe' line. A pulse between 100µs and 25ms with initiate a single transmission. This gives an idea of the usable combinations, but with a little imagination others will be found Incompatibilities: Certain operating modes are not compatible with some of the others: RX 101 (toggle) doesn't work with TX 101 (periodic send) as the outputs switch on and off at the send rate RX 100 (set and reset) doesn't work with TX 101 (as the response is sluggish) and doesn't need TX 010 (constant) RX 101 (toggle) is also not best suited to extreme range operation, where the initiation can be a little sporadic. (At extreme range, latched (011) or set/reset (100) are the best receiver modes, combined with TX 100 (send on any '1') as in this mode the failure of any single burst to be received matters less, as the operator can continue to operate the transmitter until the receiver actuates ) Serial operation: The CTA88 is capable of a very simple, single byte, serial link operation. It is selected by a '110' mode input. This function is mainly intended for diagnostic work in the lab, but it does allow a pc to send or receive CTA88 command bursts. Address is still selected by the parallel inputs On the RX: D4 = 'true' RS232 output (+ve = low (0), 0V = idle/mark state) D5 = 'inverted' RS232 output (+ve = idle/'mark' (1) state) D6 : high for 500uS before, and during, serial byte output On the TX D4 = RS232 input D5 : low = set 'true' input polarity, high = set 'inverted' input polarity In all cases a single 9600 baud byte is received or sent. The link is not transparent: on the TX end the 'tx on' pin can be used as a 'busy' output Timeout: In modes 001 and 010, the receiver outputs the last received data for a given period, before resetting D0-D7. Any subsequent transmission will over-ride the current output state and reset the timer, even if the timeout period has not expired. The short period is set to be slightly longer than the time between consecutive transmit bursts in a continuous mode. The long timeout is usable with the randomised periodic transmission mode (101), as the 3 second timeout is longer than the longest delay between transmissions in this mode. Versions of the chip can be supplied with this period extended to suit customer requirements. Radiometrix Ltd CTA88 application board manual page 6 CTA88 application boards: customisation options Features Standard Options Radio module n/a LMR/LMT(any), NiM2, BiM (any), CVR1 (5V), RDL2, RF connector Interface connectors Address select Channels SMA 3.81mm 2 part DIP switch 8 MCX, SMB, screw terminal single part screw terminals side operating DIP, ERG type slider, jumpers partial build is possible (1,2,4 ..etc channels) LEDs Push buttons fitted fitted no leds no pushbuttons only pushbuttons (no input circuits) 12V 7 – 24V 24V, and +5V only, versions are possible n/a Voltage (rx) (tx) Ordering Information Part Number RF Power Output (mW) 100 Channel Frequency (MHz) 151.300 151.300 Australia Australia CTA88-151-SHX1T-12k5-MURS CTA88-151-SHX1R-12k5-MURS 500 CH0:151.820 – CH4:154.600 CH0:151.820 – CH4:154.600 Canada, USA Canada, USA CTA88-151-LMR1-12k5-MURS CTA88-151-LMR1-12k5-MURS 100 CH0:151.820 – CH2:151.940 CH0:151.820 – CH2:151.940 Canada, USA Canada, USA CTA88-433-LMT2 CTA88-433-LMR2 10 CH0:433.050 – CH69:434.775 CH0:433.050 – CH69:434.775 Europe Europe CTA88H-458-LMT2 CTA88-458-LMR2 500 CH0:458.525 – CH23:459.100 CH0:458.525 – CH23:459.100 UK UK CTA88-434.650-NiM2T CTA88-434.650-NiM2R 10 434.650 434.650 Europe Europe CTA88-869-FPX3T CTA88-869-FPX3R 400 CH0:869.450 – CH3:869.600 CH0:869.450 – CH3:869.600 Europe Europe CTA88-151.300-BiM1T CTA88-151.300-CVR1 Radiometrix Ltd CTA88 application board manual Country page 7 Figure 5: Schematic of CTA88 Encoder application board for BiM / LMT Transmitter APPENDIX Radiometrix Ltd CTA88 application board manual page 8 Figure 6: CTA88 BiM / LMR Receiver Decoder application board Schematic Radiometrix Ltd CTA88 application board manual page 9 Figure 7: Schematic of CTA88H Encoder application board for AFS2 Amplifier, LMT2 Transmitter Figure 8: CTA88H Encoder application board for AFS2 Amplifier, LMT2 Transmitter Figure 9: Schematic of CTA88 Encoder application board for SHX1T / UHX1T / FPX33T Transmitter Figure 10: CTA88 Encoder application board SHX1T / UHX1T / FPX3T Transmitter Figure 11: Schematic of CTA88 Decoder application board for SHX1R / UHX1R / FPX3R Receiver Figure 12: CTA88 Decoder application board for SHX1R / UHX1R / FPX3R Receiver Radiometrix Ltd Hartcran House 231 Kenton Lane Harrow, Middlesex HA3 8RP ENGLAND Tel: +44 (0) 20 8909 9595 Fax: +44 (0) 20 8909 2233 [email protected] www.radiometrix.com Copyright notice This product data sheet is the original work and copyrighted property of Radiometrix Ltd. Reproduction in whole or in part must give clear acknowledgement to the copyright owner. Limitation of liability The information furnished by Radiometrix Ltd is believed to be accurate and reliable. Radiometrix Ltd reserves the right to make changes or improvements in the design, specification or manufacture of its subassembly products without notice. Radiometrix Ltd does not assume any liability arising from the application or use of any product or circuit described herein, nor for any infringements of patents or other rights of third parties which may result from the use of its products. This data sheet neither states nor implies warranty of any kind, including fitness for any particular application. These radio devices may be subject to radio interference and may not function as intended if interference is present. We do NOT recommend their use for life critical applications. The Intrastat commodity code for all our modules is: 8542 6000 R&TTE Directive After 7 April 2001 the manufacturer can only place finished product on the market under the provisions of the R&TTE Directive. Equipment within the scope of the R&TTE Directive may demonstrate compliance to the essential requirements specified in Article 3 of the Directive, as appropriate to the particular equipment. Further details are available on The Office of Communications (Ofcom) web site: http://www.ofcom.org.uk/ Information Requests Ofcom Riverside House 2a Southwark Bridge Road London SE1 9HA Tel: +44 (0)300 123 3333 or 020 7981 3040 Fax: +44 (0)20 7981 3333 [email protected] European Communications Office (ECO) Peblingehus Nansensgade 19 DK 1366 Copenhagen Tel. +45 33896300 Fax +45 33896330 [email protected] www.ero.dk