ETC RX2256

RX2256
926.0 MHz ASH Receiver
•
•
•
•
•
Ideal for 926.0 MHz, 3 V Data Receivers in the USA and Canada
High-Sensitivity Passive Design with No RF Oscillation
Baseband Data Rate of 20kbps
Simple to Apply with External Parts Count
Rugged, Surface-Mount Package with 130 mm2 Footprint
SM-10 Case
This amplifier-sequenced hybrid (ASH) receiver is based on several leading-edge
technologies that allow outstanding performance in a small and simple-to-apply
module. Two surface-accoustic-wave (SAW) devices are employed. Front-end filtering by a low-loss coupled-resonator SAW filter provides excellent selectivity.
Typical sensitivity better than -80 dBm is achieved with no RF oscillating or regenerative circuits. This results in virtually no RF spurious emissions. A low-loss SAW delay line provides the time delay necessary to sequence the two RF amplifiers. Time sequencing of
the RF gain eliminates the need for frequency conversion prior to AM detection. This receiver is designed to operate from a 3 V lithium
battery with typically 4.5 mA current. For system design flexibility, the baseband output is accessible, and the comparator threshold can
be changed externally between two settings. Typical applications include unlicensed wireless remote-controls and digital data links
operating in the USA under FCC Part 15.249 and in Canada under DOC RSS-210.
Electrical Characteristics
Characteristic
Operating Radio Frequency
Sym
Notes
fC
2, 3
Received Carrier Modulation Type
RF Band
Sensitivity
Operating Signal Strength
4, 5
6
Channel Width
Sequencing (Sampling)
Baseband
Comparator Threshold
Digital Output
Power Supply
Half-Frequency Spurious
fC ± 1 MHz
700
625
56
25
0
VOH
Output LOW Voltage
VOL
mV
11
VCC -0.2
VCC
0.0
0.2
Rise Time
tR
3
Fall Time
tF
3
Operating Voltage
VCC
Current at 25°C and 3.0 V
ICC
TA
Lid Symbolization (in addition to Lot and/or Date Codes)
Phone: (972) 233-2903
ns
kHz
kHz
10
Output HIGH Voltage
Fax: (972) 387-9148
©1998 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
1
1
2.7
3.0
4.5
-20
kHz
dB
15
10
dBm
W
80
8
Units
MHz
50 Nominal
CMOS Load Capacitance
Operating Ambient Temperature
Maximum
926.0 Nominal
7
Sample Duration
Sample Repetition Rate
3 dB Bandwidth
Default (Terminal 5 NC)
Override (Terminal 5 LOW)
Typical
Pulse Modulation (OOK)
-71
-10
fC±200
ZIN
Input Impedance
Interference Rejection
Minimum
pF
V
ms
3.5
VDC
6
mA
+70
°C
RFM RX2256
E-mail: [email protected]
http://www.rfm.com
RX2256-121198
Page 1 of 4
The RX Series SMT Hybrid ASH Receivers
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling.
Notes:
1. Unless noted otherwise, specifications apply over the entire specified operating temperature and voltage ranges.
2. One or more of the following United States patents apply: 4,454,488; 4,616,197; 4,749,964; 4,902,925. Other patents are pending.
3. Typically, equipment utilizing this device requires emissions testing and government approval, which is the responsibility of the
equipment manufacturer.
4. The design, manufacturing process, and specifications of this device are subject to change without notice.
5. A variety of on-off-keyed (OOK) pulse modulation schemes are possible since digital decoding is an external function (not included
in the ASH receiver).
6. These parameters apply over the absolute minimum operating passband which is referenced to fC.
7. With interfering signal matched to the receiver modulation and code. See “Typical Modulated Interference Rejection” for a more
detailed view.
8. Sample repetition rates greater than 1 MHz are available in custom versions. Contact RFM for details.
9. Baseband data rates are available to 20 kbps, respectively, in custom versions. Contact RFM for details. See HX/RX Designer’s
Guide for details on data rate limits.
10. The default comparator threshold (with terminal 5 not connected) is optimized for low duty-cycle, or “bursty” data and eliminates
noise output when there is no RF signal. The override threshold (with terminal 5 connected to ground) is optimized for continuous
data.
11. The ASH receiver is designed to drive a single CMOS load.
12. For ESD protection
Absolute Maximum Ratings
Rating
Incident RF Power
Power Supply Voltage (VCC to Ground)(Observe ESD Precautions)
ESD (100 pF, 1.5 kΩ)
Value
Units
+10
dBm
-0.3 to +4.0
VDC
Terminals 2, 3, or 7 to Ground
±2000
All Other Terminals to Ground
±300
-40 to +85
Case Temperature
V
°C
Block Diagram and Electrical Connections
50 ohm Antenna
Note 12
10
9
8
7
RF Input
Gnd
Gnd
Data Output
6
Voltage
Reference
1 uF
Top View
Pulse
Generator
RF
Amp.
SAW
Delay
Line
RF
Amp.
AM
Detector
LPF
SAW BPF
Comparator
Baseband
Output
2
Vcc
1
+3V
Comparator
Input
3
Gnd
4
Threshold
Override
5
10 uF
0.1 to 10 uF
RF Monolithics, Inc.
Phone: (972) 233-2903
Fax: (972) 387-9148
©1998 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
E-mail: [email protected]
http://www.rfm.com
RX2256-121198
Page 2 of 4
The RX Series SMT Hybrid ASH Receivers
Demonstration Circuit
+
1 Vcc
Note 12
RF In 10
+3V
Lithium
CR2032
1
16
2
15
10 uF
2 BB Out
Gnd 9
3
3 Comp In
Gnd 8
4
Data Out 7
5
+
.1 to 1uF
4 Gnd
5 Thres
Override
Vref 6
6
+
1 uF
OPEN: Default 25mV
CLOSED: Override OV
33 K
+
7
MC145028 Decoder
Top View
14
13
1 mA @ 3VDC
RS 273-065A or equiv
12
+ Piezo
11
Alarm
10
0.1 uF
0.1 uF
+
620 K
8
9
Typical Modulated Interference Rejection (433.92 MHz RX1000 Shown)
This plot is for an interfacing signal modulated with the receiver’s modulation and code. Continuous wave (CW) or signals with other
modulation or codes typically result in significantly better rejection performance.
Spurious Rejection Relative to Passband Sensitivity (dB)
0
0
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
100
100
110
110
120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580 600 620 640
216.96
Half Freq. Spurious
Response
RF Monolithics, Inc.
Phone: (972) 233-2903
433.92
Operating Freq.
Fax: (972) 387-9148
©1998 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
Frequency (MHz)
E-mail: [email protected]
http://www.rfm.com
RX2256-121198
Page 3 of 4
The RX Series SMT Hybrid ASH Receivers
Case Design
0.370
(9.40)
0.065
(1.65)
10 Places
0.050
(1.27)
10 Places
0.070
(1.78)
4 Places
RFM
Rxxxxx
0.540
(13.72)
0.241
(6.12)
0.10
(2.54)
0.100
(2.54)
4 Places
Typical Antennas
A
B
C
D
Ground Plane
50 Ω
Enameled Wire, AWG = G
Inner Dia = E
No. Turns = F
Frequency
Dimensions
A
B
C
D
Units
303.825
418.0
433.92
916.5
Inches
5.35
3.9
3.55
1.58
Millimeters
135.89
99.06
90.17
40.13
Inches
1.0
0.6
0.6
0.4
Millimeters
25.4
15.24
15.24
10.16
Inches
0.25
0.6
0.55
0.18
Millimeters
6.35
15.24
13.97
4.57
Inches
3.7
2.7
2.4
1.0
Millimeters
93.98
68.58
60.96
25.4
Inches
0.375
0.1
0.1
0.1
Millimeters
9.53
2.54
2.54
2.54
F
Number of Turns
4T
16T
15T
7T
G
AWG
#20
#22
#22
#24
E
RF Monolithics, Inc.
Phone: (972) 233-2903
Fax: (972) 387-9148
©1998 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
E-mail: [email protected]
http://www.rfm.com
RX2256-121198
Page 4 of 4