ETC RX2020

RX2020
916.5 MHz ASH Receiver
•
•
•
•
•
Ideal for 916.5 MHz, 3 V Data Receivers in Europe
High-Sensitivity Passive Design with No RF Oscillation
Use with HX2000 for 19.2 kbps Data Rate
Simple to Apply with External Parts Count
Rugged, Surface-Mount Package with 130 mm2 Footprint
SM-10 Case
This amplifier-sequenced hybrid (ASH) receiver is based on several leading-edge
technologies that allow outstanding performance in a small and simple-to-apply module. Two surface-accoustic-wave (SAW) devices are employed. Front-end filtering
by a low-loss coupled-resonator SAW filter provides excellent selectivity. Typical sensitivity better than -72 dBm is achieved with no
RF oscillating or regenerative circuits. This results in virtually no RF spurious emissions. A low-loss SAW delay line provides the time
delay necessary to sequence the two RF amplifiers. Time sequencing of the RF gain eliminates the need for frequency conversion prior
to AM detection. This receiver is designed to operate from a 3 V lithium battery with typically 2.5 mA current. For system design flexibility, the baseband output is accessible, and the comparator threshold can be changed externally between two settings. Typical applications include unlicensed wireless remote-controls, and digital data links operating in the USA under FCC Part 15.249 and in Canada
under DOC RSS-210.
Electrical Characteristics
Characteristic
Operating Radio Frequency
Sym
fC
Received Carrier Modulation Type
RF Band
Sensitivity
Operating Signal Strength
Channel Width
Input Impedance
Interference Rejection
Half-Frequency Spurious
fC ± 1 MHz
Sequencing (Sampling)
Sample Duration
Sample Repetition Rate
Data Rate
3 dB Bandwidth
Default (Terminal 5 NC)
Override (Terminal 5 LOW)
CMOS Load Capacitance
Baseband
Comparator Threshold
Digital Output
Power Supply
Notes
Minimum
2, 3
4, 5
6
Typical
Maximum
916.50 Nominal
MHz
Pulse Modulation (OOK)
-72
-10
fC±200
ZIN
7
9
10
W
dB
ns
kHz
kb/s
kHz
mV
Output HIGH Voltage
VOH
VCC -0.2
VCC
Output LOW Voltage
VOL
0.0
0.2
Rise Time
tR
3
Fall Time
tF
3
Operating Voltage
VCC
Current at 25C and 3.0 V
ICC
Operating Ambient Temperature
TA
Lid Symbolization (in addition to Lot and/or Date Codes)
RF Monolithics, Inc.
Phone: (972) 233-2903
Fax: (972) 387-9148
RFM Europe
Phone: 44 1963 251383
Fax: 44 1963 251510
©1998 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
1
1
2.7
kHz
80
15
10
11
dBm
50 Nominal
700
625
20
24
25
0
8
Units
pF
V
µs
3.0
3.5
VDC
2.5
3.0
mA
+85
°C
-40
RFM RX2020
E-mail: [email protected]
http://www.rfm.com
RX2020-121198
Page 1 of 4
The RX Series SMT Hybrid ASH Receivers
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling.
Notes:
1. Unless noted otherwise, specifications apply over the entire specified operating temperature and voltage ranges.
2. One or more of the following United States patents apply: 4,454,488; 4,616,197; 4,749,964; 4,902,925. Other patents are pending.
3. Typically, equipment utilizing this device requires emissions testing and government approval, which is the responsibility of the
equipment manufacturer.
4. The design, manufacturing process, and specifications of this device are subject to change without notice.
5. A variety of on-off-keyed (OOK) pulse modulation schemes are possible since digital decoding is an external function (not included
in the ASH receiver).
6. These parameters apply over the absolute minimum operating passband which is referenced to fC.
7. With interfering signal matched to the receiver modulation and code. See “Typical Modulated Interference Rejection” for a more
detailed view.
8. Sample repetition rates greater than 1 MHz are available in custom versions. Contact RFM for details.
9. Baseband data rates are available to 20 kbps, respectively, in custom versions. Contact RFM for details. See HX/RX Designer’s
Guide for details on data rate limits.
10. The default comparator threshold (with terminal 5 not connected) is optimized for low duty-cycle, or “bursty” data and eliminates
noise output when there is no RF signal. The override threshold (with terminal 5 connected to ground) is optimized for continuous
data.
11. The ASH receiver is designed to drive a single CMOS load.
12. For ESD protection.
Absolute Maximum Ratings
Rating
Incident RF Power
Power Supply Voltage (VCC to Ground)(Observe ESD Precautions)
ESD (100 pF, 1.5 kW)
Value
Units
+10
dBm
-0.3 to +4.0
VDC
Terminals 2, 3, or 7 to Ground
±2000
All Other Terminals to Ground
±300
-40 to +100
Case Temperature1
V
°C
Block Diagram and Electrical Connections
50 ohm Antenna
Note 12
10
9
8
7
RF Input
Gnd
Gnd
Data Output
6
Voltage
Reference
1 uF
Top View
Pulse
Generator
RF
Amp.
SAW
Delay
Line
RF
Amp.
AM
Detector
LPF
SAW BPF
Comparator
Baseband
Output
2
Vcc
1
+3V
Comparator
Input
3
Gnd
4
Threshold
Override
5
10 uF
0.1 to 10 uF
RF Monolithics, Inc.
Phone: (972) 233-2903
Fax: (972) 387-9148
RFM Europe
Phone: 44 1963 251383
Fax: 44 1963 251510
©1998 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
E-mail: [email protected]
http://www.rfm.com
RX2020-121198
Page 2 of 4
The RX Series SMT Hybrid ASH Receivers
Demonstration Circuit
+
1 Vcc
Note 12
RF In 10
+3V
Lithium
CR2032
1
16
2
15
10 uF
2 BB Out
Gnd 9
3
3 Comp In
Gnd 8
4
Data Out 7
5
+
.1 to 1uF
4 Gnd
5 Thres
Override
OPEN: Default 25mV
CLOSED: Override OV
Vref 6
6
+
1 uF
33 K
+
7
MC145028 Decoder
Top View
14
13
1 mA @ 3VDC
RS 273-065A or equiv
12
+ Piezo
11
Alarm
10
0.1 uF
0.1 uF
+
620 K
8
9
Typical Modulated Interference Rejection (433.92 MHz RX1000 Shown)
This plot is for an interfacing signal modulated with the receiver’s modulation and code. Continuous wave (CW) or signals with other
modulation or codes typically result in significantly better rejection performance.
Spurious Rejection Relative to Passband Sensitivity (dB)
0
0
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
100
100
110
110
120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500 520 540 560 580 600 620 640
216.96
Half Freq. Spurious
Response
433.92
Operating Freq.
RF Monolithics, Inc.
Phone: (972) 233-2903
Fax: (972) 387-9148
RFM Europe
Phone: 44 1963 251383
Fax: 44 1963 251510
©1998 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
Frequency (MHz)
E-mail: [email protected]
http://www.rfm.com
RX2020-121198
Page 3 of 4
The RX Series SMT Hybrid ASH Receivers
Case Design
0.370
(9.40)
0.065
(1.65)
10 Places
0.050
(1.27)
10 Places
0.070
(1.78)
4 Places
RFM
Rxxxxx
0.540
(13.72)
0.241
(6.12)
0.10
(2.54)
0.100
(2.54)
4 Places
Typical Antennas
A
B
C
D
Ground Plane
50 Ω
Enameled Wire, AWG = G
Inner Dia = E
No. Turns = F
Frequency
Dimensions
A
B
C
D
E
F
G
Units
Inches
Millimeters
Inches
Millimeters
Inches
Millimeters
Inches
Millimeters
Inches
Millimeters
Number of Turns
AWG
303.825
418.0
433.92
916.5
5.35
135.89
1.0
25.4
0.25
6.35
3.7
93.98
0.375
9.53
4T
#20
3.9
99.06
0.6
15.24
0.6
15.24
2.7
68.58
0.1
2.54
16T
#22
3.55
90.17
0.6
15.24
0.55
13.97
2.4
60.96
0.1
2.54
15T
#22
1.58
40.13
0.4
10.16
0.18
4.57
1.0
25.4
0.1
2.54
7T
#24
RF Monolithics, Inc.
Phone: (972) 233-2903
Fax: (972) 387-9148
RFM Europe
Phone: 44 1963 251383
Fax: 44 1963 251510
©1998 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
E-mail: [email protected]
http://www.rfm.com
RX2020-121198
Page 4 of 4