ETC 25759

Revision Guide for
AMD Athlon 64 and
AMD Opteron Processors
TM
TM
Publication # 25759
Revision: 3.09
Issue Date: September 2003
© 2003 Advanced Micro Devices, Inc. All rights reserved.
The contents of this document are provided in connection with Advanced Micro Devices,
Inc. (“AMD”) products. AMD makes no representations or warranties with respect to the
accuracy or completeness of the contents of this publication and reserves the right to make
changes to specifications and product descriptions at any time without notice. No license,
whether express, implied, arising by estoppel or otherwise, to any intellectual property
rights is granted by this publication. Except as set forth in AMD’s Standard Terms and
Conditions of Sale, AMD assumes no liability whatsoever, and disclaims any express or
implied warranty, relating to its products including, but not limited to, the implied warranty
of merchantability, fitness for a particular purpose, or infringement of any intellectual property right.
AMD’s products are not designed, intended, authorized or warranted for use as components
in systems intended for surgical implant into the body, or in other applications intended to
support or sustain life, or in any other application in which the failure of AMD’s product
could create a situation where personal injury, death, or severe property or environmental
damage may occur. AMD reserves the right to discontinue or make changes to its products
at any time without notice.
Trademarks
AMD, the AMD Arrow logo, AMD Athlon, AMD Opteron, and combinations thereof, and 3DNow!, are trademarks of
Advanced Micro Devices, Inc.
HyperTransport is a licensed trademark of the HyperTransport Technology Consortium.
Other product names used in this publication are for identification purposes only and may be trademarks of their respective companies.
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
Revision History
Date
Revision Description
September 2003
3.09
Added AMD Athlon 64, Mobile AMD Athlon 64, and AMD Athlon 64 FX
information; Revised erratum #91. Corrected erratum #77.
August 2003
3.07
Added erratum #95, #97, and #98; Modified Description in erratum #94;
Added C0 silicon information.
June 2003
3.05
Added erratum #94.
May 2003
3.03
Added erratum #92.
April 2003
3.01
Initial public release.
Revision History
3
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
4
Revision History
25759
Rev. 3.09 September 2003
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
Revision Guide for
AMD AthlonTM 64 and
AMD OpteronTM Processors
The purpose of the Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors is to
communicate updated product information to designers of computer systems and software
developers. This revision guide includes information on the following products:
•
AMD Athlon™ 64 processor
•
Mobile AMD Athlon™ 64 processor – includes desktop replacement (DTR)
•
AMD Athlon™ 64 FX processor
•
AMD Opteron™ processor
This guide consists of three major sections:
•
Revision Determination: This section, starting on page 6, describes the mechanism by which the
current revision of the part is identified.
•
Product Errata: This section, starting on page 7, provides a detailed description of product
errata, including potential effects on system operation and suggested workarounds. An erratum is
defined as a deviation from the product’s specification, and as such may cause the behavior of the
processor to deviate from the published specifications.
•
Documentation Support: This section, starting on page 49, provides a listing of available
technical support resources.
Revision Guide Policy
Occasionally, AMD identifies product errata that cause the processor to deviate from published
specifications. Descriptions of identified product errata are designed to assist system and software
designers in using the processors described in this revision guide. This revision guide may be updated
periodically.
5
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
Revision Determination
Figure 1 shows the format of the value returned in EAX by CPUID Function 1.
31
28
27
20 19
16 15
12 11
8 7
4 3
0
Reserved
Reserved (zero)
Extended Family
Extended Model
Reserved (zero)
Family
Model
Stepping
Figure 1.
31–28
27–20
19–16
15–12
11–8
7–4
3–0
Format of CPUID Value Returned by Function 1
Table 1 shows the identification number returned by the CPUID instruction for each revision of the
processor.
Table 1.
CPUID Values for Revisions of the Processors
CPUID Function 1 EAX Value
6
Revision
AMD Opteron™
Processor
AMD Athlon™ 64
Processor
AMD Athlon™ 64
FX Processor
Mobile
AMD Athlon™ 64
Processor
SH7-B3
00000F51h
N/A
N/A
N/A
SH7-C0
00000F58h
00000F48h
00000F58h
00000F48h
Revision Determination
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
Product Errata
This section documents product errata for the processors. A unique tracking number for each erratum
has been assigned within this document for user convenience in tracking the errata within specific
revision levels. Table 2 cross-references the revisions of the part to each erratum. An “X” indicates
that the erratum applies to the revision. The absence of an “X” indicates that the erratum does not
apply to the revision. An “*” indicates advance information that the erratum has been fixed but not yet
verified. “No fix planned” indicates that no fix is planned for current or future revisions of the
processor.
Note: There may be missing errata numbers. Errata that have been resolved from early revisions of
the processor have been deleted, and errata that have been reconsidered may have been
deleted or renumbered.
Table 2.
Cross-Reference of Product Revision to Errata
Errata Description
1
Inconsistent Global Page Mappings Can Lead to Machine Check Error
51
Arbitrated Interrupt With Illegal Vector Sets APIC Error Bit In All Processors
57
Some Data Cache Tag Eviction Errors Are Reported As Snoop Errors
58
Memory Latency with Processor Power States
60
Single Machine Check Error May Report Overflow
61
Real Mode RDPMC with Illegal ECX May Cause Unpredictable Operation
X
62
Task Gates With Breakpoints Enabled May Cause Unexpected Faults
X
63
TLB Flush Filter Causes Coherency Problem in Multiprocessor Systems
X
64
Single Step Across I/O SMI Skips One Debug Trap
X
65
Uncorrectable NB Machine Check Error May Disrupt Power Management
X
66
Upstream Read Response Delayed by Downstream Posted Writes
X
68
Disable DQS Hysteresis Bit Not Readable
X
69
Multiprocessor Coherency Problem with Hardware Prefetch Mechanism
X
71
RSM from SMM with Paging Enabled May Deadlock
X
74
Registered DIMM Exit-Self-Refresh Requirements Not Met
X
75
APIC Timer Accuracy Across Power Management Events
76
APIC Timer Undercounts In Divide-by-8 Low Power Mode
77
Long Mode CALLF or JMPF May Fail To Signal GP When Callgate Descriptor
is Beyond GDT/LDT Limit
Product Errata
SH7-C0
No.
SH7-B3
Revision Number
No fix planned
X
X
No fix planned
X
No fix planned
No fix planned
X
No fix planned
7
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
Table 2.
25759
Rev. 3.09 September 2003
Cross-Reference of Product Revision to Errata (Continued)
SH7-B3
SH7-C0
Revision Number
78
APIC Interrupt Latency With C2 Enabled
X
X
79
Power Management Limitations Above 1.50V
X
X
80
Registered DIMM Initialization Requirements Not Met
X
81
Cache Coherency Problem with Hardware Prefetching and Streaming Stores
X
82
Certain Faults On Far Transfer Instructions In 64-Bit Mode Save Incorrect RIP
X
83
DC Machine Check Extended Error Code Bit Not Writeable
X
85
Insufficient Delay Between MEMCLK Startup and CKE Assertion During
Resume From S3
86
DRAM Data Masking Feature Can Cause ECC Failures
88
SWAPGS May Fail To Read Correct GS Base
89
Potential Deadlock With Locked Transactions
90
False IC Machine Check Overflow Error Logged On Reset
X
X
91
Software Prefetches May Report A Page Fault
X
X
92
Deadlock In Multi-Processor Systems May Occur When Earlier Operations
Prevent An Older Store From Writing Data
X
X
93
RSM Auto-Halt Restart Returns To Incorrect RIP
94
Sequential Prefetch Feature May Cause Incorrect Processor Operation
X
X
95
RET Instruction May Return To Incorrect EIP
X
X
96
Increased Memory Latency During P-State Changes
X
X
97
128-Bit Streaming Stores May Cause Coherency Failure
X
98
LDTSTOP Assertion May Be Missed
X
No.
8
Errata Description
Product Errata
X
No fix
planned
X
X
X
No fix planned
X
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
Table 3 cross-references the errata to each processor segment. An empty cell signifies that the erratum
does not apply to the processor segment. “X” signifies that the erratum applies to the processor
segment. “N/A” signifies that the erratum does not apply to the processor segment due to the silicon
revision.
Table 3.
Cross-Reference of Errata to Processor Segments
Errata
Number
AMD Opteron™
Processor
AMD Athlon™ 64
Processor
Mobile
AMD Athlon™ 64
Processor
AMD Athlon™ 64 FX
Processor
1
X
X
X
X
51
X
57
X
X
X
X
58
X
N/A
N/A
N/A
60
X
X
X
X
61
X
N/A
N/A
N/A
62
X
N/A
N/A
N/A
63
X
64
X
N/A
N/A
N/A
65
X
N/A
N/A
N/A
66
X
N/A
N/A
N/A
68
X
N/A
N/A
N/A
69
X
71
X
N/A
N/A
N/A
74
X
N/A
N/A
N/A
75
X
X
X
X
76
X
N/A
N/A
N/A
77
X
X
X
X
78
X
X
X
X
79
X
X
X
X
80
X
N/A
81
X
N/A
N/A
N/A
82
X
N/A
N/A
N/A
83
X
X
X
X
85
X
X
X
X
86
X
X
X
X
88
X
X
X
X
89
X
X
X
X
90
X
X
X
X
91
X
X
X
X
Product Errata
N/A
9
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
Table 3.
Rev. 3.09 September 2003
Cross-Reference of Errata to Processor Segments (Continued)
AMD Athlon™ 64
Processor
Mobile
AMD Athlon™ 64
Processor
AMD Athlon™ 64 FX
Processor
X
X
X
X
94
X
X
X
X
95
X
X
X
X
X
X
Errata
Number
AMD Opteron™
Processor
92
X
93
96
10
25759
97
X
X
X
X
98
X
X
X
X
Product Errata
25759
1
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
Inconsistent Global Page Mappings Can Lead to Machine Check
Error
Description
If the same linear to physical mapping exists in multiple CR3 contexts, and that mapping is marked
global in one context and not global in another context, then a machine check error may be reported
by the TLB error detection logic (depending on the specific access pattern and TLB replacements
encountered).
Potential Effect on System
In the somewhat unlikely event that all required conditions are present (including the effects of the
TLB replacement policy), then an unexpected machine check error may be reported. If the erratum
occurs in the instruction cache TLB (L1 or L2), the apparent error is logged and corrected. If the
erratum occurs in the data cache TLB (L1 or L2), the apparent error is logged and reported as an
uncorrectable machine check error.
Suggested Workaround
If the described software scenario can be avoided, this erratum will not occur (i.e., if software never
maps the same linear page global in one context and not global in another context). If the software
scenario cannot be avoided, two other potential workarounds are possible:
1. Disable TLB error reporting in the machine check architecture (or disable the machine check
architecture entirely). Refer to the BIOS and Kernel Developer's Guide for AMD AthlonTM 64 and
AMD OpteronTM Processors, order# 26094, for information on how to program the machine check
architecture.
2. Disable the TLB flush filter by setting HWCR.FFDIS (bit 6) in MSR C001_015h.
Fix Planned
No
Product Errata
11
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
51 Arbitrated Interrupt With Illegal Vector Sets APIC Error Bit In All
Processors
Description
If an arbitrated interrupt uses an illegal interrupt vector (0–15), then the corresponding error bit is
erroneously set in the APIC Error Status Register (ESR) of all processors, not just the processor that
accepted the arbitrated interrupt. The accepting processor has its error bit set twice—once during the
arbitration phase (at the same time as all the other processors are erroneously setting their error bits),
and once during the acceptance phase.
Potential Effect on System
If an arbitrated interrupt uses an illegal vector, all processors report that error in their APIC ESR. This
is not expected to impact system operation.
In the case of the accepting processor, the error may appear to be reported twice if software clears the
ESR in the short interval between the arbitration and acceptance phases.
Suggested Workaround
None required.
Fix Planned
Yes
12
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
57 Some Data Cache Tag Eviction Errors Are Reported As Snoop
Errors
Description
In some cases, the machine check error code on a data cache (DC) tag array parity error erroneously
classifies an eviction error as a snoop error.
The common cases of cache line replacements and external probes are classified correctly (as eviction
and snoop respectively). The erroneous cases occur when a tag error is detected during a DC eviction
that was generated by a hardware prefetch, a cache line state change operation, or a number of other
internal microarchitectural events. In such cases, the error code logged in the DC Machine Check
Status register (MC0_STATUS, MSR 0x401) erroneously indicates a snoop error.
Potential Effect on System
Internally detected DC tag errors may be reported to software as having been detected by snoops.
Depending upon machine check software architecture, the system response to such errors may be
broader than necessary.
Suggested Workaround
None required.
Fix Planned
No
Product Errata
13
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
58 Memory Latency with Processor Power States
Description
If CPU Low Power mode is enabled in the C1, C2, or throttling processor power states, then
externally generated sequences of memory references may experience unexpectedly large latencies
through the memory controller.
Potential Effect on System
Long memory latencies may lead to performance anomolies or functional failures, depending on the
buffering capabilities of external devices.
Suggested Workaround
Do not enable CPU Low Power mode in the C1, C2, or throttling processor power states. Specifically,
disable the CPULowPwrEn bits for System Management Action Field (SMAF) codes 000, 101, and
111 by clearing Dev:3x80[0] for C2, Dev:3x84[24] for C1, and Dev:3x84[8] for throttling.
Fix Planned
Yes
14
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
60 Single Machine Check Error May Report Overflow
Description
A single parity error encountered in the data cache tag array may incorrectly report the detection of
multiple errors, as indicated by the overflow bit of the DC Machine Check Status register (bit 62 of
MSR 0x401).
Potential Effect on System
System software may be informed of a machine check overflow when only a single error was actually
encountered.
Suggested Workaround
Do not rely on the state of the OVER bit in the DC Machine Check Status register.
Fix Planned
No
Product Errata
15
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
61 Real Mode RDPMC with Illegal ECX May Cause Unpredictable
Operation
Description
Illegal values of ECX (that is, ECX > 3) for the RDPMC (Read Performance Monitor Counter)
instruction correctly cause the processor to take a general protection exception.
However, if the RDPMC instruction is executed in real mode with a specific illegal value of ECX = 9,
then the processor may incorrectly enter the GP fault handler as if it were in 32-bit mode.
Potential Effect on System
Incorrect instruction decode leading to unpredictable system failure.
Suggested Workaround
When in real mode, restrict use of the RDPMC instruction to the legal counter values (0–3). This
circumstance is not expected to occur in normal operation and has only been detected in a simulation
environment.
Fix Planned
Yes
16
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
62 Task Gates With Breakpoints Enabled May Cause Unexpected
Faults
Description
When a task gate is used by a CALL or JMP instruction and any debug breakpoint is enabled through
the DR7.LE or GE bits, the processor may incorrectly use the new TSS base [15:0] contained in the
new TSS as a selector. This will most likely lead to a GP fault with an error code of the new TSS base.
Potential Effect on System
Unexpected faults leading to unpredictable system failure.
Suggested Workaround
When running software that uses task gates with CALL or JMP instructions, do not enable debug
breakpoints.
Fix Planned
Yes
Product Errata
17
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
63 TLB Flush Filter Causes Coherency Problem in Multiprocessor
Systems
Description
If the TLB flush filter is enabled in a multiprocessor configuration, coherency problems may arise
between the page tables in memory and the translations stored in the on-chip TLBs. This can result in
the possible use of stale translations even after software has performed a TLB flush.
Potential Effect on System
Unpredictable system failure.
Suggested Workaround
In MP systems, disable the TLB flush filter by setting HWCR.FFDIS (bit 6 of MSR 0xC001_0015).
Fix Planned
Yes
18
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
64 Single Step Across I/O SMI Skips One Debug Trap
Description
When single stepping (with EFLAGS.TF) accross an IN or OUT instruction that detects an SMI, the
processor correcly defers taking the debug trap and instead enters SMM. Upon RSM (without I/O
restart), the processor should immediately enter the debug trap handler.
Under this senario, the processor does not enter the debug trap handler but instead returns to the
instruction following the I/O instruction.
Potential Effect on System
When using the single step debug mode, following an I/O operation that detects an SMI, one
instruction may appear to be skipped.
Suggested Workaround
None required as this is a debug limitation only. If a workaround is desired, modify the SMM handler
to detect this case and enter the debug handler directly.
Fix Planned
Yes
Product Errata
19
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
65 Uncorrectable NB Machine Check Error May Disrupt Power
Management
Description
If an uncorrectable machine check error in the Northbridge (NB) error reporting bank is detected at
approximately the same time as any of the following events, then the intended power management
activity may be disrupted and various failures may result:
•
A HyperTransport™ link frequency change
•
Entry into the S3 state (suspend-to-RAM)
Potential Effect on System
For HyperTransport link frequency changes, undefined operation results, leading to unpredicatble
system failure.
For entry into the S3 power state, the DRAM is not put into self-refresh state, leading to likely
corruption of DRAM contents.
Suggested Workaround
A workaround may not be required since this erratum only occurs in the presence of a fatal machine
check error, and even then only when it happens to coincide in a small window of time with one of the
power management events described.
If desired, the NB error reporting bank MCG_CTL, MSR 0x17B, bit 4 (NBE), (or all of the machine
check architecture) can be disabled by software around the time of these events. Refer to the BIOS
and Kernel Developer's Guide for AMD Athlon™ 64 and AMD Opteron™ Processors, order# 26094,
for information on how to program the machine check architecture.
Fix Planned
Yes
20
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
66 Upstream Read Response Delayed by Downstream Posted
Writes
Description
An upstream read to main memory can be delayed when the following sequence occurs:
1. The processor issues one or more posted writes downstream.
2. The processor evicts a line from its cache.
3. The chipset performs an upstream read to memory with the PassPW bit set in the HyperTransport
packet.
In this case, the read should pass the downstream posted writes but due to a resource conflict in the
internal request queues, the read is delayed until the processor’s cache line is written and all
previously enqueued posted writes have completed.
Potential Effect on System
Unexpectedly large latencies may be experienced during upstream memory reads, potentially
resulting in performance anomolies or functional failures, depending on the buffering capabilities of
external devices.
Suggested Workaround
Limit the number of processor downstream posted requests to one by programming the following
register values:
•
Set Dev:3x70[1:0] to 10b (SRI-to-XBAR buffer counts)
•
Set Dev:3x7C[5:4] to 00b (Free list buffer counts)
Note that a warm reset is required to allow these new values to take effect.
Fix Planned
Yes
Product Errata
21
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
68 Disable DQS Hysteresis Bit Not Readable
Description
The DisDqsHys bit of the DRAM Config Low register (Dev:2x90[3]) is writeable and performs its
intended function, but it incorrectly always reads as zero to software.
Potential Effect on System
None expected. This bit is configured by BIOS and readability is not required.
Suggested Workaround
Perform writes to the DisDqsHys bit as appropriate for the system, disregarding the value read back.
Fix Planned
Yes
22
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
69 Multiprocessor Coherency Problem with Hardware Prefetch
Mechanism
Description
If the on-chip hardware prefetch mechansim generates a prefetch with write intent for a cache line
that is also found to be present in the instruction cache, then the eventual prefetch response from the
system is incorrectly discarded by the processor.
In the event the prefetched line was transferred in the modified state from another processor’s cache,
that processor’s modified data is lost.
Potential Effect on System
Multiprocessor memory coherency issues leading to unpredictable system failure.
Suggested Workaround
In MP systems, set BU_CFG.WbPfSmcChkDis (bit 45 of MSR 0xC001_1023). No loss of
performance results from this workaround.
Fix Planned
Yes
Product Errata
23
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
71 RSM from SMM with Paging Enabled May Deadlock
Description
Under a rare set of internal timing circumstances, a speculative TLB reload may incorrectly interact
with the RSM instruction such that the processor becomes deadlocked. This can only occur if the
SMM handler configures and enables its own paging environment.
Potential Effect on System
The system hangs and recovers only after a system reset is performed.
Suggested Workaround
If paging is enabled in the SMM handler, disable it (by clearing CR0.PG) before executing the RSM
instruction.
Fix Planned
Yes
24
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
74 Registered DIMM Exit-Self-Refresh Requirements Not Met
Description
When sequencing registered DIMMs out of self refresh state at the completion of an S1, S3 or
LDTSTOP_L initiated HyperTransport link width/frequency change, certain sequencing
requirements of the registered DIMMs are not met.
Potential Effect on System
Memory system failure leading to unpredictable system failure.
Suggested Workaround
Do not use S1 S3 on a platform that employs registered DIMMs.
HyperTransport link width/frequency changes must be initiated using warm reset (as opposed to
LDTSTOP_L).
Fix Planned
Yes
Product Errata
25
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
75 APIC Timer Accuracy Across Power Management Events
Description
The APIC timer may be inaccurate by up to 1 µs across each use of S1or LDTSTOP_L initiated
HyperTransport link width/frequency changes.
Potential Effect on System
No observable system impact expected.
Suggested Workaround
None.
Fix Planned
No
26
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
76 APIC Timer Undercounts In Divide-by-8 Low Power Mode
Description
If S1 or LDTSTOP_L initiated HyperTransport link width/frequency changes are performed with the
Clock Divisor Select (ClkSel) set to divide-by-8, then the APIC timer incorrectly counts at 1/8 its
intended rate. This miscounting remains in effect for as long as the processor remains in the divideby-8 mode.
Potential Effect on System
For S1, the divide-by-8 mode is not typically used, so no sytem implication is expected.
LDTSTOP_L initiated HyperTransport link width/frequency changes do typically use the divide-by-8
ClkSel setting (to minimize latency) and are therefore affected by this erratum. However, for these
operations the time spent in the divide-by-8 mode is limited to approximately 1 µs per use, implying
the APIC timer may lose approximately 0.875 µs each time one of these transitions is performed. This
error would be in addition to any other APIC timer accuracy errors that may exist.
Suggested Workaround
None required. The accuracy loss is small and no observable system impact is expected.
Fix Planned
Yes
Product Errata
27
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
77 Long Mode CALLF or JMPF May Fail To Signal GP When Callgate
Descriptor is Beyond GDT/LDT Limit
Description
If the target selector of a far call or far jump (CALLF or JMPF) instruction references a 16-byte long
mode system descriptor where any of the last 8 bytes are beyond the GDT or LDT limit, the processor
fails to report a General Protection fault.
Potential Effect on System
None expected, since the operating system typically aligns the GDT/LDT limit such that all
descriptors are legal. However, in the case of erroneous operating system code, the above described
GP fault will not be signalled, resulting in unpredictable system failure.
Suggested Workaround
None required, it is anticipated that long mode operating system code will ensure the GDT and LDT
limits are set high enough to cover the larger (16-byte) long mode system descriptors.
Fix Planned
No
28
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
78 APIC Interrupt Latency With C2 Enabled
Description
If an APIC interrupt is delivered to the processor at a time when interrupts are masked (i.e.,
EFLAGS.IF=0), and just shortly before entering the C2 power state, then the interrupt may
experience a long latency before being serviced.
The interrupt is not lost, but it is not serviced until some other wakeup event (for example, a timer
tick) occurs to take the processor out of the C2 state.
Potential Effect on System
Excessively long interrupt latencies may occur, resulting in unpredictable system failures.
Suggested Workaround
Do not enable the C2 power state.
Fix Planned
Yes
Product Errata
29
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
79 Power Management Limitations Above 1.50V
Description
Processor versions with a core voltage greater than 1.50V do not support Northbridge low power
mode while in the S1 power state or LDTSTOP_L initiated HyperTransport link width/frequency
changes.
Potential Effect on System
Unpredictable system failures may occur.
Suggested Workaround
For affected versions of the processor, do not enable Northbridge low power mode in the S1 power
state. Specifically, clear the NBLowPwrEn bit in SMAF code 011 of the Power Mangement Control
Registers (i.e., clear Dev:3x80[25]).
Also, use warm reset (rather than LDTSTOP_L) to initiate HyperTransport link width/frequency
changes.
Fix Planned
Yes
30
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
80 Registered DIMM Initialization Requirements Not Met
Description
When initializing registered DIMMs after a powerup or warm reset assertion, the time interval
between the deassertion of MEMRESET_L and the assertion of CKE is not sufficient for some
DIMMs.
Potential Effect on System
The memory system may fail to initialize, leading to boot failure.
Suggested Workaround
A board level workaround is available for this problem, see Methodologies for Using Registered
DIMMs with AMD Athlon™ 64 and AMD Opteron™ Processors, order #27510, for details.
Fix Planned
Yes
Product Errata
31
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
81 Cache Coherency Problem with Hardware Prefetching and
Streaming Stores
Description
If the processor's hardware prefetch mechanism initiates a cache line prefetch at approximately the
same time as a streaming store (MOVNT* or MASKMOV*) is performed to that same address, then a
stale copy of that line may be loaded into the cache.
Potential Effect on System
Cache coherency failure leading to unpredictable system failure. This erratum affects both
uniprocessor and multiprocessor configurations. It has only ever been observed in a randomized
diagnostic environment.
Suggested Workaround
Set DC_CFG.DIS_SMC_CHK_BUF (bit 10 of MSR 0xC001_1022) to disable the SMC check buffer
for streaming stores. No loss of functionality occurs as a result of setting this bit.
Fix Planned
Yes
32
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
82 Certain Faults On Far Transfer Instructions In 64-Bit Mode Save
Incorrect RIP
Description
This erratum affects the far transfer instructions (CALLF, RETF, IRET, JMPF) in 64-bit mode. If a far
transfer is executed in 64-bit mode and:
•
The RIP of the far transfer is 4 GB or greater (> 32 bits)
•
The target is a 32-bit compatibility segment
•
The far transfer encounters a fault _after_ loading the CS
then the RIP pushed onto the exception handler stack will be erroneously truncated to 32-bits. The
following table lists the instructions and faults that are subject to this erratum.
Instruction
Fault
CALLF (intersegment, no gate)
Target limit violation
Faults on stack pushes
JMPF (intersegment, no gate)
Target limit violation
RETF/IRET (no CPL change)
Target limit violation
RETF/IRET (with CPL change)
Target limit violation
Fault while loading new SS
Potential Effect on System
The fault handler will return to the incorrect address if it attempts to IRET back to the faulting
instruction (the far transfer), leading to unpredictable system failures.
Suggested Workaround
None required. This erratum can only affect 64-bit operating systems, but has never been seen in such
systems. It has only been seen in random instruction testing.
This erratum can only affect kernel operating system code, not applications since transfers from 64bit mode to 32-bit compatibility can only be done by the kernel. Furthermore, existing 64-bit
operating systems provide enough error checking and are constructed such that it is not possible to
encounter one of the above faults at the point the kernel uses the far transfers to exit to a 32-bit
compatibility application.
Fix Planned
Yes
Product Errata
33
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
83 DC Machine Check Extended Error Code Bit Not Writeable
Description
The extended error code bit in the DC Machine Check Status Register (i.e., bit 16 of MSR 0x0401)
cannot be predictably updated by software. When this register is written, bit 16 may be updated to
either a zero or a one depending on internal processor conditions.
The ability of this register to correctly log and classify machine check errors is not compromised by
this erratum. When an error occurs, all status information (including the extended error code bit) is
captured correctly and is readable by software. The erratum only affects the software writeability of
this bit.
Potential Effect on System
None expected. As described, errors are captured and classified correctly and are software readable.
Since software only interprets the extended error code bit in the context of a valid TLB error, the
inability of software to clear that extended error bit is of no functional consequence.
Suggested Workaround
None required.
Fix Planned
Yes
34
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
85 Insufficient Delay Between MEMCLK Startup and CKE Assertion
During Resume From S3
Description
When sequencing the DRAMs out of self refresh during a resume from the S3 (Suspend-to-RAM)
state, the processor fails to insert sufficient delay between MEMCLK startup and CKE assertion.
Potential Effect on System
Memory system failure leading to unpredictable system failure.
Suggested Workaround
Modify the resume from S3 BIOS sequence such that sufficient delay is inserted between the time
MEMCLK is enabled in the DRAM Config High Register (Dev:2x94) and the time the ESR and
SR_S bits are written in the DRAM Config Low Register (Dev:2x90[13:12]) to exit self refresh. For
registered DIMMs, 100 µs of delay is required. For unbuffered DIMMs, 10 µs of delay is required.
Fix Planned
No
Product Errata
35
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
86 DRAM Data Masking Feature Can Cause ECC Failures
Description
Under certain conditions, the memory controller fails to generate a DRAM read request when
performing partial writes to an already allocated write combining buffer. Because the DRAM is not
read for these subsequent write requests, the generated ECC bits are incorrect.
Potential Effect on System
Incorrect data can be read back from DRAM.
Suggested Workaround
BIOS should disable the data masking feature when ECC DIMMs are used by setting the DisDatMsk
bit (Northbridge Configuration Register - MSR C001_001F, bit 36).
Fix Planned
Yes
36
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
88 SWAPGS May Fail To Read Correct GS Base
Description
The SWAPGS instruction fails to cause an input dependency on the GS segment register. If the GS
segment register has been recently changed via a MOV or POP segment register instruction,
SWAPGS may incorrectly save the old value of GS base into the KernelGSbase MSR.
Potential Effect on System
The KernelGSbase MSR may be corrupted.
Suggested Workaround
Between a MOV/POP into GS and any subsequent SWAPGS there must be a synchronizing
operation. That operation can be one of the following:
•
Any of the instructions that are required by the x86 architecture to be serializing
(see AMD64 Architecture Programmer's Manual Volume 2: System Programming, order# 24593).
•
A trap, interrupt or exception.
•
An SFENCE or MFENCE instruction.
•
An instruction that flushes the pipeline:
- CALLF, JMPF, RETF, INTn, IRET, SYSCALL, SYSRET.
The MFENCE alternative is the lowest latency and the recommended alternative. The others are
mentioned in case the code already satisfies them by construction.
Fix Planned
Yes
Product Errata
37
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
89 Potential Deadlock With Locked Transactions
Description
Downstream non-posted requests to devices that are dependent on the completion of an upstream
non-posted request can cause a deadlock in the presence of transactions resulting in bus locks, as
shown in the following two scenarios:
1. A downstream non-posted read to the LPC bus occurs while an LPC bus DMA is in progress. The
legacy LPC DMA blocks downstream traffic until it completes its upstream reads.
2. A downstream non-posted read is sent to a device that must first send an upstream non-posted
read before it can complete the downstream read.
In both cases, a locked transaction causes the upstream channel to be blocked, causing the deadlock
condition.
Potential Effect on System
The system fails due to a bus deadlock.
Suggested Workaround
BIOS should set the DisIOReqLock bit (bit 3 in NB_CFG, MSR C001_001F).
Fix Planned
No
38
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
90 False IC Machine Check Overflow Error Logged On Reset
Description
If a processor cold or warm reset occurs during a precise window when the instruction cache is being
accessed due to a branch re-direct, a false IC Machine Check Overflow error may be logged in the IC
Machine Check Status register.
Potential Effect on System
System operation is not compromised, but a false machine check overflow error (bit 62) may be
reported in the IC Machine Check Status register.
Suggested Workaround
After a cold or warm reset, BIOS should clear the IC Machine Check Status register if the valid bit in
that register is 0.
Fix Planned
Yes
Product Errata
39
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
91 Software Prefetches May Report A Page Fault
Description
Software prefetch instructions are defined to ignore page faults. Under highly specific and detailed
internal circumstances, a prefetch instruction may report a page fault if both of the following
conditions are true:
•
The target address of the prefetch would cause a page fault if the address was accessed by an
actual memory load or store instruction under the current privilege mode;
•
The prefetch instruction is followed in execution-order by an actual or speculative byte-sized
memory access of the same modify-intent to the same address.
PREFETCH and PREFETCHNTA/0/1/2 have the same modify-intent as a memory load access.
PREFETCHW has the same modify-intent as a memory store access.
The page fault exception error code bits for the faulting prefetch will be identical to that for a bytesized memory access of the same-modify intent to the same address.
Note that some misaligned accesses can be broken up by the processor into multiple accesses where at
least one of the accesses is a byte-sized access.
If the target address of the subsequent memory access of the same modify-intent is aligned and not
byte-sized, this errata does not occur and no workaround is needed.
Potential Effect on System
An unexpected page fault may occur infrequently on a prefetch instruction.
Suggested Workaround
Two workarounds are described for this erratum.
Kernel Workaround
The Operating System kernel can work around the erratum by allowing the page fault handler to
satisfy the page fault to an "accessible" page regardless of whether the fault was due to a load, store,
or prefetch operation. If the faulting instruction is permitted access to the page, return to it as usual.
(An "accessible" page is one for which memory accesses are allowed under the current privilege
mode once the page is resident in memory).
If the faulting instruction is trying to access an "inaccessible" page, scan the instruction stream bytes
at the faulting Instruction Pointer to determine if the instruction is a prefetch. (An "inaccessible" page
is one for which memory accesses are not allowed under the current privilege mode.) If the faulting
instruction is a prefetch instruction, simply return back to it; the internal hardware conditions that
caused the prefetch to fault should be removed and operation should continue normally. If it is not a
prefetch instruction, generate the appropriate memory access control violation as appropriate. The
performance impact of doing the scan is small because the actual errata is infrequent and does not
produce an excessive number of page faults that affect system performance.
General Workaround
If the page-fault handler for a kernel can be patched as described in the preceding kernel workaround,
no further action by software is required. The following general workarounds should only be
40
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
considered for kernels where the page-fault handler can not be patched and a prefetch instruction
could end up targeting an address in an "inaccessible" page.
Because the actual errata is infrequent, it does not produce an excessive number of page faults that
affect system performance. Therefore a page fault from a prefetch instruction for an address within
an "accessible" page does not require any general workaround.
Software can minimize the occurrence of the errata by issuing only one prefetch instruction per
cache-line (a naturally-aligned 64-byte quantity) and ensuring one of the following:
•
In many cases, if a particular target address of a prefetch is known to encounter this errata, simply
change the prefetch to target the next byte.
•
Avoid prefetching inaccessible memory locations, when possible.
•
In the general case, ensure that the address used by the prefetch is offset into the middle of an
aligned quadword near the end of the cache-line. For example, if the address desired to be
prefetched is "ADDR", use an offset of 0x33 to compute the address used by the actual prefetch
instruction as: "(ADDR & ~0x3f) + 0x33".
Fix Planned
Yes
Product Errata
41
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
92 Deadlock In Multi-Processor Systems May Occur When Earlier
Operations Prevent An Older Store From Writing Data
Description
A system deadlock may occur in multi-processor systems under the following conditions:
1. Interrupts are disabled.
2. A store operation occurs to a cacheable memory type.
3. The store is retired but not yet written the data cache.
4. The store is followed by a persistent (infinite) stream of loads while some of the loads are
misaligned.
5. The misaligned loads are to the same cache index as the store (i.e., bits 11:6 are the same).
6. The misaligned loads are continually picked in the cycle preceding the store.
7. The destination cache line of the store is in a state other than modified (i.e., a probe from another
processor to the same address as the store has previously transitioned this line to a shared state).
Potential Effect on System
In the unlikely event that the above conditions occcur, the system hangs.
Suggested Workaround
None. This scenario was contrived in a highly randomized synthetic stress test and is not expected to
occur in real systems.
Fix Planned
Yes
42
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
93 RSM Auto-Halt Restart Returns To Incorrect RIP
Description
If an SMI occurs on a HALT instruction in 64-bit mode, and the subsequent RSM uses the
Auto-Halt Restart feature, the RIP will incorrectly truncate to 32 bits.
Potential Effect on System
Unpredictable system operation.
Suggested Workaround
If the upper 32 bits of RIP are not cleared to zeroes, BIOS should clear the Auto-Halt Restart byte
before executing the RSM instruction in the SMI handler. The RIP content can be verified and the
Auto-Halt Restart byte can be modified in the SMM State-Save area in SM mode.
Fix Planned
Yes
Product Errata
43
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
94 Sequential Prefetch Feature May Cause Incorrect Processor
Operation
Description
On an instruction cache miss, the sequential prefetch mechanism may enable the early prefetch of the
next sequential cache line. Under a highly specific set of internal pipeline conditions this mechanism
may cause the processor to hang or execute incorrect code in 64-bit systems running 32-bit
compatibility mode applications.
Potential Effect on System
Processor may deadlock or execute incorrect code.
Suggested Workaround
BIOS should disable IC sequential prefetch by setting IC_CFG.DIS_SEQ_PREFETCH (bit 11 of
MSR C001_1021).
Fix Planned
Yes
44
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
95 RET Instruction May Return To Incorrect EIP
Description
In order to efficiently predict return addresses, the processor implements a 12-deep return address
stack to pair RETs with previous CALLs.
Under the following unusual and specific conditions, an overflowed hardware return stack may cause
a RET instruction to return to an incorrect EIP in 64-bit systems running 32-bit compatibility mode
applications:
•
A CALL near is executed in 32-bit compatibility mode.
•
Prior to a return from the called procedure, the processor is switched to 64-bit mode.
•
In 64-bit mode, subsequent CALLs are nested 12 levels deep or greater.
•
The lower 32 bits of the 64-bit return address for the 12th-most deeply nested CALL in 64-bit
mode matches exactly the 32-bit return address of the original 32-bit mode CALL.
•
A series of RETs is executed from the nested 64-bit procedures.
•
The processor returns to 32-bit compatibility mode.
•
A RET is executed from the originally called procedure.
Potential Effect on System
The processor returns to an incorrect EIP, causing unpredictable system operation.
Suggested Workaround
None. This has been observed in synthetic load stress-testing only, and not in any operating system or
application.
Fix Planned
Yes
Product Errata
45
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
96 Increased Memory Latency During P-State Changes
Description
The memory controller's idle counters are dynamically managed to help reduce page misses and
conflicts. When LDTSTOP is asserted for a P-state (frequency) change, the memory controller
incorrectly waits for the idle counters to expire before placing DRAM in self-refresh. This has the
effect of increasing memory latency (up to 256 memory clocks in rare cases) during P-state changes.
Potential Effect on System
The slight increase in memory latency may lead to performance anomalies depending on buffering
capabilities of external devices.
Suggested Workaround
None.
Fix Planned
Yes
46
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
97 128-Bit Streaming Stores May Cause Coherency Failure
Description
Under a specific set of internal pipeline conditions, stale data may be left in the L1 cache when a 128bit streaming store (MOVNT*) to a writeback (WB) memory type misses in the L1 data cache and
both L1 and L2 TLBs.
Potential Effect on System
Memory coherence failures leading to unpredictable operation.
Suggested Workaround
Set DC_CFG.DIS_CNV_WC_SSO (bit 3 of MSR 0xC001_1022). The performance effects of setting
this bit are limited to streaming stores to the write-combining (WC) memory type, a case expected to
rarely occur in actual usage. No loss of performance occurs in the general case (WB memory type).
This workaround must not be applied to processors prior to revision C0.
Fix Planned
Yes
Product Errata
47
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
25759
Rev. 3.09 September 2003
98 LDTSTOP Assertion May Be Missed
Description
If LDTSTOP width is too short relative to the programmed value of Clock Ramp Hysteresis, the
LDTSTOP assertion may be missed.
Potential Effect on System
FID changes or HyperTransport width/frequency changes may not work correctly.
Suggested Workaround
Program the Clock Ramp Hysterisis value (Dev:3xD4 [10-8]) to be less than the LDTSTOP pulse
width.
Fix Planned
Yes
48
Product Errata
25759
Rev. 3.09
September 2003
Revision Guide for AMD Athlon™ 64 and AMD Opteron™ Processors
Documentation Support
The following documents provide additional information regarding the operation of the processor:
•
AMD Athlon™ 64 Processor Data Sheet, order# 24659
•
AMD Opteron™ Processor Data Sheet, order# 23932
•
AMD Athlon™ 64 FX Processor Data Sheet, order# 30431
•
CPUID Guide for AMD Athlon™ 64 and AMD Opteron™ Processors: Application Note
Addendum, order# 25481
•
BIOS and Kernel Developer’s Guide for AMD Athlon™ 64 and AMD Opteron™ Processors,
order# 26094
•
AMD Athlon™ 64 Processor Motherboard Design Guide, order# 24665
•
AMD64 Architecture Programmer's Manual Volume 1: Application Programming, order# 24592
•
AMD64 Architecture Programmer's Manual Volume 2: System Programming, order# 24593
•
AMD64 Architecture Programmer's Manual Volume 3: Instruction-Set Reference, order# 24594
•
AMD64 Architecture Programmer's Manual Volume 4: 128-Bit Media Instructions, order# 26568
•
AMD64 Architecture Programmer's Manual Volume 5: 64-Bit Media and x87 Floating-Point
Instructions, order# 26569
•
Methodologies for Using Registered DIMMs with AMD Athlon™ 64 and AMD Opteron™
Processors, order# 27510
See the AMD Web site at www.amd.com for the latest updates to documents. For documents subject
to a non-disclosure agreement (NDA), please contact your local sales representative.