ETC 3561500002

M INIA
TURE FUSES
INIATURE
WICKMANN
6.3x32mm / No. 356
Special TType,
ype, 440V
440V,, T
Specifications
Time-Current Characteristic
Packaging
Time Lag (T)
000: Bulk (500 pcs.)
002: Pack (100 pcs.)
Standard
Materials
None
Tube:
End Caps:
Approvals
cULus Recognized: File No. E 67006
Operating TTemperature
emperature
Features
-25ºC to +70ºC (consider de-rating)
For high voltage applications
Surge tolerant
High breaking capacity
Agency approved
Pluggable into clips or shocksafe holders
Dimensions (mm)
WebLinks
-25ºC/+70ºC/21 days (EN 60068-1..3)
Stock Conditions
+10ºC to +60ºC
relative humidity ≤ 75% yearly average,
without dew, maximum value for 30 days-95%
24 cycles at 15 min. each (EN 60068-6)
10 - 60Hz at 0.75mm amplitude
60 - 2000Hz at 10g acceleration
www.wickmann.com/products/356.pdf
Approval Certificates
32
Climatic Category
Vibration Resistance
Data Sheet
∅ 6,3
Ceramic
Nickel-plated brass
www.wickmann.com/approvals
Marking
T ime-Current Curve
, T, Current Rating, 440V, Approvals
www.wickmann.com/itcurves
Unit W
eight
Weight
FaxBack Document # 212
3.0g (approx.)
Limits for Pre-arcing Time
1.5 x IRated
2.5 x IRated
4 x IRated
10 x IRated
400mA ... 10.00A
> 1h
< 15 min
150ms ... 2s
10ms ... 300ms
Permissible continuous operating current is ≤ 100
% at ambient temperature of 23ºC (73.4ºF).
100%
Rated
Amp
Voltage
Breaking
Voltage Drop Power Dissipation Melting Integral
Current
Code
Rating
Capacity
1.0 x IRated
1.5 x IRated
10 x IRated
max. (mV)
max. (W)
min. (A2s)
400mA
500mA
630mA
800mA
1.00A
1.25A
1.60A
2.00A
2.50A
3.15A
4.00A
5.00A 1
6.30A 1
8.00A 1
10.00A 1
0400
0500
0630
0800
1100
1125
1160
1200
1250
1315
1400
1500
1630
1800
2100
440V
440V
440V
440V
440V
440V
440V
440V
440V
440V
440V
440V
440V
440V
440V
1000A / 440VAC
50-60Hz
cos ϕ = 1.0
1200
1100
800
700
500
350
320
270
250
230
200
180
150
140
120
1.5
1.6
1.7
1.7
1.8
1.8
1.8
2.0
2.3
2.4
2.6
3.0
3.2
3.8
4.0
0.16
0.53
2.0
3.1
4.4
3.1
8.3
9.2
22
36
62
91
130
240
510
Approvals
cURus
Rated Current
•
•
•
•
•
•
•
•
•
•
•
1 Depending on the application and mounting, the fuse heating at max. ambient temperature in a closed fuseholder should be considered.
Order
Information
000801
Qty.
WebSite: www.wickmann.com
FaxBack: +1 (404) 699-6176
OrderNumber
Series
356
Amp Code
Packaging
• Europe Tel: +49 (2302) 662-107 • Americas Tel: +1 (404) 699-7820
• Asia Tel: +852 26 14-1108
E-mail: [email protected]
E-mail: [email protected] E-mail: [email protected]
M INIA
TURE FUSES
INIATURE
WICKMANN
10
6.3x32mm / No. 356
0 ,0
00
I-t Cha racteristic s
(M in-M ax Lim it)
10
,0 0
0
1 ,0
00
10
10
Time (sec.)
0
1
0 .1
0 .0
1
0 .0
01
1
1 .5
2
3
4
5
6
7
8 9 10
15
I Fault / I Rated
Contact WICKMANN for individual I-t curves
000801
WebSite: www.wickmann.com
FaxBack: +1 (404) 699-6176
• Europe Tel: +49 (2302) 662-107 • Americas Tel: +1 (404) 699-7820
• Asia Tel: +852 26 14-1108
E-mail: [email protected]