ETC 4191500000

SURFACE MOUNT FUSES
WICKMANN
SMQ / No. 419
UL 248-14, 125V
125V,, F
Specifications
Time-Current Characteristic
Packaging
Quick Acting (F)
000: Blister Tape (1000 pcs.)
Standard
Materials
UL 248-14
CSA C22.2 No. 248.14
Housing:
Element:
Terminals:
Approvals (pending)
Operating TTemperature
emperature
cULus Recognized: File No. E 67006
-40ºC to +85ºC (consider de-rating)
Features
Climatic Category
Flame resistant ceramic housing
For line or low voltage applications
Low voltage drop
Internationally approved
Dimensions (mm)
-40ºC/+85ºC/21 days (IEC 60068-2-1...3)
Stock Conditions
+10ºC to +60ºC
relative humidity ≤ 75% yearly average,
without dew, maximum value for 30 days-95%
WebLinks
max. 2,7
6,1 ±0,2
V ibration Resistance
Data Sheet
24 cycles at 15 min. each (IEC 60068-2-6)
10 - 60Hz at 0.75mm amplitude
60 - 2000Hz at 10g acceleration
www.wickmann.com/products/419.pdf
Approval Certificates
www.wickmann.com/approvals
1,45 -0,2
Solderability
Time-Current Curve
1,45 -0,2
235ºC, 3 sec. (IEC 60068-2-58)
Page 70
www.wickmann.com/itcurves
Pad Layout
260ºC, 10 sec. (IEC 60068-2-58)
Minimum Cross Section, Copper
Page 118
www.wickmann.com/pack
Conducting path - 0.1mm 2
Path thickness - 0.035mm
FaxBack Document # 328
3,15 +0,05
1,96 +0,05
Soldering Heat Resistance
Packaging
2,95 +0,05
Ceramic
Wire
Copper alloy, tin plated
Mounting
Solder the fuse with the marked side facing up
Avoid circuit traces below the fuse
Marking
1,96 +0,05
, F, Current Rating
Unit Weight
0.23g (approx.)
Limits for Pre-arcing Time
2.0 x IRated
250mA ... 10.00A
< 60s
< 5s
Permissible continuous operating current is ≤ 70% at ambient temperature of 23ºC (73.4ºF).
Rated
Amp
Voltage
Breaking Voltage Drop Power Dissipation
Current
Code
Rating
Capacity 1.0 x IRated
1.0 x IRated
typ. (mV)
typ. (mW)
250mA
500mA
750mA
1.00A
1.50A
2.00A
2.50A
3.00A
4.00A
5.00A
7.00A
8.00 A
10.00A
0250
0500
0750
1100
1150
1200
1250
1300
1400
1500
1700
1800
2100
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
50A / 125VAC/DC
50-60Hz
cos ϕ = 1.0
35A AC / 50A DC~
35A / 125VAC/DC
360
210
200
180
220
160
140
130
130
95
100
300
230
370
400
550
600
670
750
1200
800
1400
Melting Integral
10 x IRated
max. (A2s) typ. (A2s)
0.27
0.50
1.10
1.10
1.20
2.00
4.30
7.50
13.60
20.00
27.00
0.22
0.42
0.89
0.90
0.95
1.70
3.42
6.80
11.60
17.00
23.50
Approvals
cURus
2.0 x IRated
cUL
Rated Current
P
P
P
P
P
P
P
P
P
P
P
P Pending
Order
Information
010226
Qty.
WebSite: www.wickmann.com
FaxBack: +1 (404) 699-6176
OrderNumber
Series
419
Amp Code
Packaging
• Europe Tel: +49 (2302) 662-107 • Americas Tel: +1 (404) 699-7820
• Asia Tel: +852 26 14-1108
E-mail: [email protected]
E-mail: [email protected] E-mail: [email protected]
SURFACE MOUNT FUSES
WICKMANN
10
SMQ / No. 419
0 ,0
00
I-t C har ac te ristic s
(M in -M ax Lim it)
10
U L 2 4 8-1 4
T es t v alu e
,0 0
0
1 ,0
00
10
10
Time (sec.)
0
1
0 .1
0 .0
1
0 .0
01
1
1 .5
2
3
4
5
6
7
8 9 10
15
I Fault / IRated
Contact WICKMANN for individual I-t curves
WebSite: www.wickmann.com
FaxBack: +1 (404) 699-6176
• Europe Tel: +49 (2302) 662-107 • Americas Tel: +1 (404) 699-7820
• Asia Tel: +852 26 14-1108
E-mail: [email protected]