ETC 620238

Eveready Battery Company, Inc.
533 Maryville University Drive
St. Louis, MO 63141
Telephone 1-800-383-7323
Internet: www.energizer.com
Engineering Data
Alkaline 9V
No Added Mercury or Cadmium
ENERGIZER
NO. X522
Chemical System: Zinc-Manganese Dioxide (Zn/MnO2)
Dimensions (mm)
Millimeters
12.45
12.95
15.50
17.50
24.50
26.50
44.07
44.83
46.50
48.50
Inches
0.490
0.510
0.610
0.689
0.965
1.043
1.735
1.765
1.831
1.909
Designation: ANSI-1604A, IEC-6LR61
Battery Voltage: 9 Volts
Average Weight: 45.6 grams (1.60 oz.)
Volume: 21.1 cubic centimeters (1.3 cubic inch)
Average Service capacity (to 0.8 Volts / cell): 595 mAh
(Rated Capacity at 25 mA continuous drain)
Cell: Six No. X3-0316 in series
Jacket: Metal
Shelf Life: 5 years
Temperature Effects
Typical Service to 4.8 Volts
1000
45oC
20oC
Service, Hours
100
10
-10oC
1
0.1
10
Constant Resistance Discharge
Typical Service
1000
100
Service, Hours
Service, Hours
1000
Constant Current Discharge
Typical Service
1000
100
100
Discharge Resistance, Ohms
4.8
5.4
6.0
10
6.6
7.2
7.8
1
4.8
5.4
6.0
10
6.6
7.2
7.8
1
0.1
0.1
10
Form No. EBC - 1185A
100
Discharge Resistance, Ohms
1000
1
10
100
Discharge Current, mA
1000
ENERGIZER
NO. X522
Internal Resistance
Typical Values at 20o C (70o F)
Internal Resistance
(Milliohms)
12
10
8
6
4
2
0
0
10
20
30
40
50
60
Depth of Discharge (%)
70
80
90
Typical Applications
Radio
620 ohms 2 hours / day
10
10
9
9
8
Voltage, CCV
Voltage, CCV
Toy
270 ohms 1 hour / day
7
6
5
8
7
6
5
4
4
0
5
10
15
20
25
30
35
40
45
50
55
60
0
Service, Hours
3
6
9
Calculator
180 ohms 1/2 hour / day
10
Voltage, CCV
9
8
7
6
5
4
0
2
4
6
8
Service, Hours
10
12
14
Important Notice
This data sheet contains information specific to batteries manufactured at
time of its publication. Please contact your Energizer representative for
most current information. Contents herein do not constitute a warranty.
Form No. EBC - 1185A
12
15
Service, Hours
18
21
24