PRODUCT DATASHEET European Region + 44 (0) 208 920 2306 www.energizer.eu AA Rechargeable AA-2400 (HR6) Specifications Industry Standard Dimensions Classification: Chemical System: ACCU Rechargeable Nickel-Metal Hydride (NiMH) Designation: Nominal Voltage: Rated Capacity: IEC-HR6 1.2 Volts 2400 mAh (to 1.0 volts) Based on 480 mA (0.2C) discharge rate Typical Weight: Typical Volume: Jacket: 28.0 grams 8.3 cubic centimeters Plastic Label (mm) 14.50 13.50 1.00 Minimum 5.50 Maximum Internal Resistance: The internal resistance of the cell varies with state of charge, as follows: Cell 1/2 Discharged Cell Charged 30 milliohms 40 milliohms (tolerance of ±20% applies to above values) 50.50 49.20 AC Impedance (No Load): 7.00 Minimum The impedance of the charged cell varies with frequency, as follows: Typical Discharge Characteristics Cell Voltage 1.4 1000 1.3 240 mA (0.1C) 1.2 480 mA (0.2C) 1.1 Above values based on AC current set at 1.0 ampere. Value tolerances are ±20%. 1.0 Operating and Storage Temperatures: 0.9 0 3 6 Hours of Discharge 9 12 To maintain maximum performance, observe the following general guidelines regarding environmental conditions. Charge: Discharge: Storage: Humidity: Typical Performance at 21ºC 1.4 Cell Voltage Impedance (milliohms) (Charged Cell) 12 Frequency (Hz) Typical Performance at 21ºC 1.3 1.2 1.1 4.8 A (2.0C) 1.0 1.2 A (0.5C) 2.4 A (1.0C) 0ºC to 40ºC 0ºC to 50ºC -20ºC to 30ºC 65±20% Operating at extreme temperatures, will significantly impact battery cycle life. 0.9 0.0 0.5 1.0 1.5 2.0 2.5 Hours of Discharge Important Notice This datasheet contains information specific to battery chargers manufactured at the time of its publication. ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty. Form No. EBC - 889960EU Page 1 of 1