ENERGIZER 635429

PRODUCT DATASHEET
European Region
+ 44 (0) 208 920 2306
www.energizer.eu
AA
Rechargeable AA-2400 (HR6)
Specifications
Industry Standard Dimensions
Classification:
Chemical System:
ACCU Rechargeable
Nickel-Metal Hydride (NiMH)
Designation:
Nominal Voltage:
Rated Capacity:
IEC-HR6
1.2 Volts
2400 mAh (to 1.0 volts)
Based on 480 mA (0.2C) discharge rate
Typical Weight:
Typical Volume:
Jacket:
28.0 grams
8.3 cubic centimeters
Plastic Label
(mm)
14.50
13.50
1.00
Minimum
5.50
Maximum
Internal Resistance:
The internal resistance of the cell varies
with state of charge, as follows:
Cell 1/2 Discharged
Cell Charged
30 milliohms
40 milliohms
(tolerance of ±20% applies to above values)
50.50
49.20
AC Impedance (No Load):
7.00
Minimum
The impedance of the charged cell varies
with frequency, as follows:
Typical Discharge Characteristics
Cell Voltage
1.4
1000
1.3
240 mA
(0.1C)
1.2
480 mA
(0.2C)
1.1
Above values based on AC current set at 1.0 ampere.
Value tolerances are ±20%.
1.0
Operating and Storage Temperatures:
0.9
0
3
6
Hours of Discharge
9
12
To maintain maximum performance, observe the following
general guidelines regarding environmental conditions.
Charge:
Discharge:
Storage:
Humidity:
Typical Performance at 21ºC
1.4
Cell Voltage
Impedance (milliohms)
(Charged Cell)
12
Frequency (Hz)
Typical Performance at 21ºC
1.3
1.2
1.1
4.8 A
(2.0C)
1.0
1.2 A
(0.5C)
2.4 A
(1.0C)
0ºC to 40ºC
0ºC to 50ºC
-20ºC to 30ºC
65±20%
Operating at extreme temperatures,
will significantly impact battery cycle life.
0.9
0.0
0.5
1.0
1.5
2.0
2.5
Hours of Discharge
Important Notice
This datasheet contains information specific to battery chargers manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 889960EU
Page 1 of 1