AXIAL LEAD AND CARTRIDGE FUSES SUBMINIATURE LT-5™ Time Lag Extended Breaking Capacity Fuse 664 Series D ® ® V E • Similar to the 663 fuse, this fuse is designed with a higher breaking capacity. • Meets IEC 127-3/4 specifications. • Available in short and long lead variations. ELECTRICAL CHARACTERISTICS: % of Ampere Rating 210% 275% 400% 1000% Time 2 minutes, Maximum .4 sec Min.; 10 seconds Maximum .1 sec Min.; 3 seconds Maximum .02 sec Min. .15 seconds Maximum AGENCY APPROVALS: IEC 127-3/4: Semko and VDE approved through 4A. Recognized under the Components Program Underwriters Laboratories and recognized by CSA. 8.5 (.335") INTERRUPTING RATINGS: 100A at 250 VAC. PACKAGING: Please refer to the following suffixes when ordering. Bulk 100 pieces: Short Lead (Bulk) HXSL Long Lead (Bulk) HXLL Tape and Reel 750 pieces: Long Lead (Tape and Reel IEC 286-2) ZRLL 1.45 (.057") 8.5 (.335") 1.45 (.057") 8.45 (.333") 0.8 (.031") 4.3 (.169") 0.64 (.025") 0.8 (.031") 5.08 3.2 (.200") (.126") PATENTED Ampere Rating .800 1.00 1.25 1.60 2.00 2.50 3.15 4.00 5.00 6.30 Voltage Rating 250 250 250 250 250 250 250 250 250 250 5.08 (.200") Average Time Current Curves 800mA 1A 1.25A 1.6A 2A 2.5A 3.15A 4A 5A 6.3A Catalog Number 0664.800 0664 001. 0664 1.25 0664 01.6 0664 002. 0664 02.5 0664 3.15 0664 004. 0664 005. 0664 06.3 18.8 (.740") 0.64 (.025") ORDERING INFORMATION: Nominal Melting I2t (A2 Sec) 2.2 4.4 6.3 10 16 32 57 77 155 262 8.45 (.333") 1000 100 TIME IN SECONDS Refer to page 96 for LT-5TM holder information. 10 1 0.1 0.01 0.001 .1 1 10 CURRENT IN AMPERES 100