Bussmann® Dura-Lag DLS-R Dual-Element, Time-Delay Construction Grade Fuses Class RK5 – 600 Volt 1 –600 Amps Dimensional Data 5.5" (± 0.31) 5" (± 0.31) 1.06" (± 0.008) .81" (± 0.008) ⁄Ω¡ºA to 30A 35A to 60A A B Dimensions (inches) Ampere Ratings 70-100 110-200 225-400 450-600 Catalog Symbol: DLS-R (600V) Current-Limiting Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Voltage Rating: 600 Volts AC (or less) Self-Certified for 300 Vdc Interrupting Rating: 200,000A RMS Symmetrical 20,000A DC Agency Approvals: U.L. Listed, Std. 248-12, Guide JDDZ, File E4273 CSA Certified, C22.2 No. 248.12, Class 1422-02, File 53787 Catalog Numbers DLS-R-1 DLS-R-10 DLS-R-100 DLS-R-1flΩ¡º DLS-R-12 DLS-R-110 DLS-R-2 DLS-R-15 DLS-R-125 DLS-R-2⁄Ω™ DLS-R-17⁄Ω™ DLS-R-150 DLS-R-2 8Ω¡º DLS-R-20 DLS-R-175 DLS-R-3 DLS-R-25 DLS-R-200 DLS-R-32Ω¡º DLS-R-30 DLS-R-225 DLS-R-3⁄Ω™ DLS-R-35 DLS-R-250 DLS-R-4 DLS-R-40 DLS-R-300 DLS-R-5 DLS-R-45 DLS-R-350 DLS-R-6 DLS-R-50 DLS-R-400 DLS-R-6⁄Ω¢ DLS-R-60 DLS-R-500 DLS-R-7 DLS-R-70 DLS-R-600 DLS-R-8 DLS-R-80 — DLS-R-9 DLS-R-90 — A 7.88 (± 0.062) 9.63 (± 0.062) 11.63 (± 0.094) 13.38 (± 0.094) 1.16 1.66 2.38 2.88 B (± 0.008) (± 0.008) (± 0.008) (± 0.008) General Information: • Designed for contractor needs. • Protects industrial equipment and large motors. • Recommended for AC power distribution system mains, feeders and branch circuits. • Industry standard time-delay of 10 seconds at 5 times the fuse rating. Carton Quantity and Weight Ampere Ratings Weight* Carton Qty. Lbs. Kg. ⁄Ω¡º–30 10 1.62 0.729 35–60 10 3.00 1.35 70–100 5 2.20 1.0 110–200 1 1.10 0.5 225–400 1 2.36 1.1 450–600 1 3.44 1.5 *Weight per carton. CE logo denotes compliance with European Union Low Voltage Directive (50-1000 Vac, 75-1500 Vdc). Refer to BIF document #8002 or contact Bussmann Application Engineering at 636-527-1270 for more information. 2-18-00 SB99006 Rev. A Form No. DLS-R Page 1 of 3 BIF Doc #1022 Bussmann® Dura-Lag DLS-R Dual-Element, Time-Delay Construction Grade Fuses Class RK5 – 600 Volt 1 –600 Amps 1 1.25 1.6 2 2.5 3.2 4 5 6.25 8 .6 .8 .2 .3 .4 100 .1 .5 Time-Current Characteristic Curves–Average Melt AMPERE RATING RMS SYMMETRICAL CURRENT IN AMPERES TIME IN SECONDS 10 1 RMS SYMMETRICAL CURRENT IN AMPERES 2-18-00 SB99006 Rev. A 100 0.1 1 .01 10 .1 PROSPECTIVE SHORT-CIRCUIT CURRENT SYMMETRICAL RMS AMPERES Form No. DLS-R Page 2 of 3 BIF Doc #1022 Bussmann® Dura-Lag DLS-R Dual-Element, Time-Delay Construction Grade Fuses 1 Amp –600 Amps Class RK5 – 600 Volt Time-Current Characteristic Curves–Average Melt The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 2-18-00 SB99006 Rev. A Form No. DLS-R Page 3 of 3 BIF Doc #1022