ETC SY10/100EL35

SY10EL35
SY100EL35
FINAL
JK FLIP-FLOP
FEATURES
■
■
■
■
■
DESCRIPTION
525ps propagation delay
2.2GHz toggle frequency
High bandwidth output transistions
Internal 75KΩ input pull-down resistors
Available in 8-pin SOIC package
The SY10/100EL35 are high-speed JK Flip-Flops. The
J/K data enters the master portion of the flip-flop when
the clock is LOW and is transferred to the slave and,
thus, the outputs, upon a positive transition of the clock.
The reset pin is asynchronous and is activated with a
logic HIGH.
TRUTH TABLE(1)
PIN CONFIGURATION/BLOCK DIAGRAM
J
1
K
2
CLK
3
J
8
K
VCC
7
Q
6
Q
5
VEE
R
R
4
J
K
R
CLK
Qn+1
L
L
L
Z
Qn
L
H
L
Z
L
H
L
L
Z
H
H
H
L
Z
Qn
X
X
H
X
L
NOTE:
1. Z = LOW-to-HIGH transition.
SOIC
TOP VIEW
Rev.: F
1
Amendment: /0
Issue Date: February 2003
SY10EL35
SY100EL35
Micrel
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = GND
TA = –40°C
Symbol
IEE
VEE
IIH
TA = 0°C
TA = +25°C
TA = +85°C
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Power Supply Current
10EL
100EL
—
—
27
27
32
32
—
—
27
27
32
32
—
—
27
27
32
32
—
—
27
32
32
37
Power Supply Voltage
10EL
100EL
—
—
–5.2
–4.5
—
—
–5.5
–5.5
–4.75
–4.20
–5.2
–4.5
–5.5
–5.5
–4.75
–4.20
–5.2
–4.5
–5.5
–5.5
Input HIGH Current
—
—
150
150
—
—
150
—
—
150
Unit
mA
V
–4.75 –5.2
–4.20 –4.5
—
—
µA
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = GND
TA = –40°C
Symbol
Parameter
TA = 0°C
TA = +25°C
TA = +85°C
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
fMAX
Maximum Toggle
Frequency
1.4
2.0
—
1.8
2.2
—
1.8
2.2
—
1.8
2.2
—
GHz
tPLH
tPHL
Propagation Delay CLK
to Output
MR
290
225
515
450
—
—
340
275
515
450
690
625
350
275
525
450
700
625
395
350
570
525
745
700
ps
tS
Set-up Time
150
0
—
150
0
—
150
0
—
150
0
—
ps
tH
Hold Time
250
100
—
250
100
—
250
100
—
250
100
—
ps
tRR
Reset Recovery
400
200
—
400
200
—
400
200
—
400
200
—
ps
tPW
Minimum Pulse Width
CLK, Reset
400
—
—
400
—
—
400
—
—
400
—
—
ps
tr
tf
Output Rise/Fall Times Q
(20% to 80%)
100
225
350
100
225
350
100
225
350
100
225
350
ps
PRODUCT ORDERING CODE
Ordering
Code
SY10EL35ZC
SY10EL35ZCTR*
SY100EL35ZC
SY100EL35ZCTR*
Package
Type
Operating
Range
Marking
Code
Z8-1
Commercial
HEL35
Z8-1
Z8-1
Z8-1
Commercial
Commercial
Commercial
Ordering
Code
Package
Type
Operating
Range
Marking
Code
SY10EL35ZI(1)
Z8-1
Industrial
HEL35
HEL35
SY10EL35ZITR*(1)
Z8-1
Industrial
HEL35
XEL35
SY100EL35ZI(1)
Z8-1
Industrial
XEL35
XEL35
SY100EL35ZITR*(1)
Z8-1
Industrial
XEL35
*Tape and Reel
Note 1.
*Tape and Reel
Recommended for new designs.
2
SY10EL35
SY100EL35
Micrel
8 LEAD SOIC .150" WIDE (Z8-1)
Rev. 03
3
SY10EL35
SY100EL35
Micrel
MICREL, INC.
TEL
1849 FORTUNE DRIVE SAN JOSE, CA 95131
+ 1 (408) 944-0800
FAX
+ 1 (408) 944-0970
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2003 Micrel, Incorporated.
4