LM19 2.4V, 10μA, TO-92 Temperature Sensor General Description The LM19 is a precision analog output CMOS integrated-circuit temperature sensor that operates over a −55°C to +130° C temperature range. The power supply operating range is +2.4 V to +5.5 V. The transfer function of LM19 is predominately linear, yet has a slight predictable parabolic curvature. The accuracy of the LM19 when specified to a parabolic transfer function is ±2.5°C at an ambient temperature of +30° C. The temperature error increases linearly and reaches a maximum of ±3.8°C at the temperature range extremes. The temperature range is affected by the power supply voltage. At a power supply voltage of 2.7 V to 5.5 V the temperature range extremes are +130°C and −55°C. Decreasing the power supply voltage to 2.4 V changes the negative extreme to −30°C, while the positive remains at +130°C. The LM19's quiescent current is less than 10 μA. Therefore, self-heating is less than 0.02°C in still air. Shutdown capability for the LM19 is intrinsic because its inherent low power consumption allows it to be powered directly from the output of many logic gates or does not necessitate shutdown at all. Applications ■ ■ ■ ■ Cellular Phones Computers Power Supply Modules Battery Management ■ ■ ■ ■ ■ FAX Machines Printers HVAC Disk Drives Appliances Features ■ ■ ■ ■ ■ Rated for full −55°C to +130°C range Available in a TO-92 package Predictable curvature error Suitable for remote applications UL Recognized Component Key Specifications ■ Accuracy at +30°C ■ Accuracy at +130°C & −55°C ■ Power Supply Voltage Range ■ Current Drain ■ Nonlinearity ■ Output Impedance ■ Load Regulation 0 μA < IL< +16 μA ±2.5 °C (max) ±3.5 to ±3.8 °C (max) +2.4V to +5.5V 10 μA (max) ±0.4 % (typ) 160 Ω (max) −2.5 mV (max) Typical Application Output Voltage vs Temperature 20004002 VO = (−3.88×10−6×T2) + (−1.15×10−2×T) + 1.8639 or where: T is temperature, and VO is the measured output voltage of the LM19. 20004024 FIGURE 1. Full-Range Celsius (Centigrade) Temperature Sensor (−55°C to +130°C) Operating from a Single Li-Ion Battery Cell © 2010 National Semiconductor Corporation 200040 www.national.com LM19 2.4V, 10μA, TO-92 Temperature Sensor January 26, 2010 LM19 Temperature (T) Typical VO +130°C +303 mV +100°C +675 mV +80°C +919 mV +30°C +1515 mV +25°C +1574 mV 0°C +1863.9 mV −30°C +2205 mV −40°C +2318 mV −55°C +2485 mV Connection Diagram TO-92 20004001 See NS Package Number Z03A Ordering Information Order Number LM19CIZ www.national.com Temperature Accuracy Temperature Range NS Package Number Device Marking ±3.8°C −55°C to +130°C Z03A LM19CIZ 2 Transport Media Bulk Supply Voltage Output Voltage Output Current Input Current at any pin (Note 2) Storage Temperature Maximum Junction Temperature (TJMAX) ESD Susceptibility (Note 3) : Human Body Model +6.5V to −0.2V (V+ + 0.6 V) to −0.6 V 10 mA 5 mA −65°C to +150°C +150°C Operating Ratings +240°C (Note 1) TMIN ≤ TA ≤ TMAX Specified Temperature Range: 2.4 V ≤ V+≤ 2.7 V −30°C ≤ TA ≤ +130°C 2.7 V ≤ V+≤ 5.5 V Supply Voltage Range (V+) −55°C ≤ TA ≤ +130°C +2.4 V to +5.5 V Thermal Resistance, θJA(Note 4) TO-92 2500 V 250 V 150°C/W Electrical Characteristics Unless otherwise noted, these specifications apply for V+ = +2.7 VDC. Boldface limits apply for TA = TJ = TMIN to TMAX ; all other limits TA = TJ = 25°C; Unless otherwise noted. Parameter Temperature to Voltage Error VO = (−3.88×10−6×T2) + (−1.15×10−2×T) + 1.8639V (Note 7) Conditions Typical (Note 5) LM19C Limits (Note 6) Units (Limit) TA = +25°C to +30°C ±2.5 °C (max) TA = +130°C ±3.5 °C (max) TA = +125°C ±3.5 °C (max) TA = +100°C ±3.2 °C (max) TA = +85°C ±3.1 °C (max) TA = +80°C ±3.0 °C (max) TA = 0°C ±2.9 °C (max) TA = −30°C ±3.3 °C (min) TA = −40°C ±3.5 °C (max) ±3.8 °C (max) TA = −55°C Output Voltage at 0°C +1.8639 V Variance from Curve ±1.0 °C ±0.4 % Non-Linearity (Note 8) −20°C ≤ TA ≤ +80°C Sensor Gain (Temperature Sensitivity −30°C ≤ TA ≤ +100°C or Average Slope) to equation: VO=−11.77 mV/°C×T+1.860V −11.0 −12.6 mV/°C (min) mV/°C (max) 160 Ω (max) −2.5 mV (max) +2. 4 V ≤ V+ ≤ +5.0V +3.7 mV/V (max) +5.0 V ≤ +11 mV (max) Output Impedance 0 μA ≤ IL ≤ +16 μA Load Regulation(Note 9) 0 μA ≤ IL ≤ +16 μA −11.77 (Note 10, Note 11) (Note 10, Note 11) Line Regulation Quiescent Current V+ +2. 4 V ≤ V+ ≤ +5.0V 4.5 7 μA (max) +5.0V ≤ 4.5 9 μA (max) ≤ +5.0V 4.5 10 μA (max) +2. 4 V ≤ V+ ≤ +5.5V +0.7 μA −11 nA/°C 0.02 μA V+ +2. 4 V ≤ Change of Quiescent Current ≤ +5.5 V ≤ +5.5V V+ Temperature Coefficient of Quiescent Current Shutdown Current V+ ≤ +0.8 V 3 www.national.com LM19 Machine Model Lead Temperature TO-92 Package Soldering (3 seconds dwell) Absolute Maximum Ratings (Note 1) LM19 Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test conditions. Note 2: When the input voltage (VI) at any pin exceeds power supplies (VI < GND or VI > V+), the current at that pin should be limited to 5 mA. Note 3: The human body model is a 100 pF capacitor discharged through a 1.5 kΩ resistor into each pin. The machine model is a 200 pF capacitor discharged directly into each pin. Note 4: The junction to ambient thermal resistance (θJA) is specified without a heat sink in still air. Note 5: Typicals are at TJ = TA = 25°C and represent most likely parametric norm. Note 6: Limits are guaranteed to National's AOQL (Average Outgoing Quality Level). Note 7: Accuracy is defined as the error between the measured and calculated output voltage at the specified conditions of voltage, current, and temperature (expressed in°C). Note 8: Non-Linearity is defined as the deviation of the calculated output-voltage-versus-temperature curve from the best-fit straight line, over the temperature range specified. Note 9: Regulation is measured at constant junction temperature, using pulse testing with a low duty cycle. Changes in output due to heating effects can be computed by multiplying the internal dissipation by the thermal resistance. Note 10: Negative currents are flowing into the LM19. Positive currents are flowing out of the LM19. Using this convention the LM19 can at most sink −1 μA and source +16 μA. Note 11: Load regulation or output impedance specifications apply over the supply voltage range of +2.4V to +5.5V. Note 12: Line regulation is calculated by subtracting the output voltage at the highest supply input voltage from the output voltage at the lowest supply input voltage. Typical Performance Characteristics Temperature Error vs. Temperature Thermal Response in Still Air 20004035 20004034 m = −7.76 × 10−6× T − 0.0115, 1.0 LM19 Transfer Function where T is the middle of the temperature range of interest and m is in V/°C. For example for the temperature range of Tmin= −30 to Tmax=+100°C: The LM19's transfer function can be described in different ways with varying levels of precision. A simple linear transfer function, with good accuracy near 25°C, is T=35°C VO= −11.69 mV/°C × T + 1.8663 V and Over the full operating temperature range of −55°C to +130° C, best accuracy can be obtained by using the parabolic transfer function m = −11.77 mV/°C The offset of the linear transfer function can be calculated using the following equation: VO = (−3.88×10−6×T2) + (−1.15×10−2×T) + 1.8639 b = (VOP(Tmax) + VOP(T) − m × (Tmax+T))/2 solving for T: , where: • VOP(Tmax) is the calculated output voltage at Tmax using the parabolic transfer function for VO • VOP(T) is the calculated output voltage at T using the parabolic transfer function for VO. Using this procedure the best fit linear transfer function for many popular temperature ranges was calculated in Figure 2. As shown in Figure 2 the error that is introduced by the linear transfer function increases with wider temperature ranges. A linear transfer function can be used over a limited temperature range by calculating a slope and offset that give best results over that range. A linear transfer function can be calculated from the parabolic transfer function of the LM19. The slope of the linear transfer function can be calculated using the following equation: www.national.com 4 Temperature Range Tmax (°C) Linear Equation VO= Maximum Deviation of Linear Equation from Parabolic Equation (°C) −55 +130 −11.79 mV/°C × T + 1.8528 V ±1.41 −40 +110 −11.77 mV/°C × T + 1.8577 V ±0.93 −30 +100 −11.77 mV/°C × T + 1.8605 V ±0.70 ±0.65 -40 +85 −11.67 mV/°C × T + 1.8583 V −10 +65 −11.71 mV/°C × T + 1.8641 V ±0.23 +35 +45 −11.81 mV/°C × T + 1.8701 V ±0.004 +20 +30 −11.69 mV/°C × T + 1.8663 V ±0.004 FIGURE 2. First Order Equations Optimized For Different Temperature Ranges. tual temperature being measured care should be taken to minimize the load current that the LM19 is required to drive. The tables shown in Figure 3 summarize the rise in die temperature of the LM19 without any loading, and the thermal resistance for different conditions. 2.0 Mounting The LM19 can be applied easily in the same way as other integrated-circuit temperature sensors. It can be glued or cemented to a surface. The temperature that the LM19 is sensing will be within about +0.02°C of the surface temperature to which the LM19's leads are attached. This presumes that the ambient air temperature is almost the same as the surface temperature; if the air temperature were much higher or lower than the surface temperature, the actual temperature measured would be at an intermediate temperature between the surface temperature and the air temperature. To ensure good thermal conductivity the backside of the LM19 die is directly attached to the GND pin. The tempertures of the lands and traces to the other leads of the LM19 will also affect the temperature that is being sensed. Alternatively, the LM19 can be mounted inside a sealed-end metal tube, and can then be dipped into a bath or screwed into a threaded hole in a tank. As with any IC, the LM19 and accompanying wiring and circuits must be kept insulated and dry, to avoid leakage and corrosion. This is especially true if the circuit may operate at cold temperatures where condensation can occur. Printed-circuit coatings and varnishes such as Humiseal and epoxy paints or dips are often used to ensure that moisture cannot corrode the LM19 or its connections. The thermal resistance junction to ambient (θJA) is the parameter used to calculate the rise of a device junction temperature due to its power dissipation. For the LM19 the equation used to calculate the rise in the die temperature is as follows: TJ = TA + θJA [(V+ IQ) + (V+ − VO) IL] where IQ is the quiescent current and ILis the load current on the output. Since the LM19's junction temperature is the ac- TO-92 no heat sink θJA TO-92 small heat fin TJ − TA θJA TJ − TA (°C/W) (°C) (°C/W) (°C) Still air 150 TBD TBD TBD Moving air TBD TBD TBD TBD FIGURE 3. Temperature Rise of LM19 Due to Self-Heating and Thermal Resistance (θJA) 3.0 Capacitive Loads The LM19 handles capacitive loading well. Without any precautions, the LM19 can drive any capacitive load less than 300 pF as shown in Figure 4. Over the specified temperature range the LM19 has a maximum output impedance of 160 Ω. In an extremely noisy environment it may be necessary to add some filtering to minimize noise pickup. It is recommended that 0.1 μF be added from V+ to GND to bypass the power supply voltage, as shown in Figure 5. In a noisy environment it may even be necessary to add a capacitor from the output to ground with a series resistor as shown in Figure 5. A 1 μF output capacitor with the 160 Ω maximum output impedance and a 200 Ω series resistor will form a 442 Hz lowpass filter. Since the thermal time constant of the LM19 is much slower, the overall response time of the LM19 will not be significantly affected. 20004015 FIGURE 4. LM19 No Decoupling Required for Capacitive Loads Less than 300 pF. 5 www.national.com LM19 Tmin (°C) LM19 R (Ω) C (µF) 200 1 470 0.1 680 0.01 1k 0.001 FIGURE 5. LM19 with Filter for Noisy Environment and Capacitive Loading greater than 300 pF. Either placement of resistor as shown above is just as effective. 20004016 20004033 4.0 Applications Circuits 20004018 FIGURE 6. Centigrade Thermostat 20004019 FIGURE 7. Conserving Power Dissipation with Shutdown www.national.com 6 LM19 20004028 Most CMOS ADCs found in ASICs have a sampled data comparator input structure that is notorious for causing grief to analog output devices such as the LM19 and many op amps. The cause of this grief is the requirement of instantaneous charge of the input sampling capacitor in the ADC. This requirement is easily accommodated by the addition of a capacitor. Since not all ADCs have identical input stages, the charge requirements will vary necessitating a different value of compensating capacitor. This ADC is shown as an example only. If a digital output temperature is required please refer to devices such as the LM74. FIGURE 8. Suggested Connection to a Sampling Analog to Digital Converter Input Stage 7 www.national.com LM19 Physical Dimensions inches (millimeters) unless otherwise noted 3-Lead TO-92 Plastic Package (Z) Order Number LM19CIZ NS Package Number Z03A www.national.com 8 LM19 Notes 9 www.national.com LM19 2.4V, 10μA, TO-92 Temperature Sensor Notes For more National Semiconductor product information and proven design tools, visit the following Web sites at: www.national.com Products Design Support Amplifiers www.national.com/amplifiers WEBENCH® Tools www.national.com/webench Audio www.national.com/audio App Notes www.national.com/appnotes Clock and Timing www.national.com/timing Reference Designs www.national.com/refdesigns Data Converters www.national.com/adc Samples www.national.com/samples Interface www.national.com/interface Eval Boards www.national.com/evalboards LVDS www.national.com/lvds Packaging www.national.com/packaging Power Management www.national.com/power Green Compliance www.national.com/quality/green Switching Regulators www.national.com/switchers Distributors www.national.com/contacts LDOs www.national.com/ldo Quality and Reliability www.national.com/quality LED Lighting www.national.com/led Feedback/Support www.national.com/feedback Voltage References www.national.com/vref Design Made Easy www.national.com/easy www.national.com/powerwise Applications & Markets www.national.com/solutions Mil/Aero www.national.com/milaero PowerWise® Solutions Serial Digital Interface (SDI) www.national.com/sdi Temperature Sensors www.national.com/tempsensors SolarMagic™ www.national.com/solarmagic PLL/VCO www.national.com/wireless www.national.com/training PowerWise® Design University THE CONTENTS OF THIS DOCUMENT ARE PROVIDED IN CONNECTION WITH NATIONAL SEMICONDUCTOR CORPORATION (“NATIONAL”) PRODUCTS. NATIONAL MAKES NO REPRESENTATIONS OR WARRANTIES WITH RESPECT TO THE ACCURACY OR COMPLETENESS OF THE CONTENTS OF THIS PUBLICATION AND RESERVES THE RIGHT TO MAKE CHANGES TO SPECIFICATIONS AND PRODUCT DESCRIPTIONS AT ANY TIME WITHOUT NOTICE. NO LICENSE, WHETHER EXPRESS, IMPLIED, ARISING BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. TESTING AND OTHER QUALITY CONTROLS ARE USED TO THE EXTENT NATIONAL DEEMS NECESSARY TO SUPPORT NATIONAL’S PRODUCT WARRANTY. EXCEPT WHERE MANDATED BY GOVERNMENT REQUIREMENTS, TESTING OF ALL PARAMETERS OF EACH PRODUCT IS NOT NECESSARILY PERFORMED. NATIONAL ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR BUYER PRODUCT DESIGN. BUYERS ARE RESPONSIBLE FOR THEIR PRODUCTS AND APPLICATIONS USING NATIONAL COMPONENTS. PRIOR TO USING OR DISTRIBUTING ANY PRODUCTS THAT INCLUDE NATIONAL COMPONENTS, BUYERS SHOULD PROVIDE ADEQUATE DESIGN, TESTING AND OPERATING SAFEGUARDS. EXCEPT AS PROVIDED IN NATIONAL’S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NATIONAL ASSUMES NO LIABILITY WHATSOEVER, AND NATIONAL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO THE SALE AND/OR USE OF NATIONAL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. LIFE SUPPORT POLICY NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: Life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. National Semiconductor and the National Semiconductor logo are registered trademarks of National Semiconductor Corporation. All other brand or product names may be trademarks or registered trademarks of their respective holders. Copyright© 2010 National Semiconductor Corporation For the most current product information visit us at www.national.com National Semiconductor Americas Technical Support Center Email: [email protected] Tel: 1-800-272-9959 www.national.com National Semiconductor Europe Technical Support Center Email: [email protected] National Semiconductor Asia Pacific Technical Support Center Email: [email protected] National Semiconductor Japan Technical Support Center Email: [email protected]