ETC AT29LV040A-20JI

Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Single Voltage, Range 3V to 3.6V Supply
3-Volt Only Read and Write Operation
Software Protected Programming
Fast Read Access Time - 200 ns
Low Power Dissipation
– 15 mA Active Current
– 40 µA CMOS Standby Current
Sector Program Operation
– Single Cycle Reprogram (Erase and Program)
– 2048 Sectors (256 bytes/sector)
– Internal Address and Data Latches for 256 Bytes
Two 16K Bytes Boot Blocks with Lockout
Fast Sector Program Cycle Time - 20 ms Max.
Internal Program Control and Timer
DATA Polling for End of Program Detection
Typical Endurance > 10,000 Cycles
CMOS and TTL Compatible Inputs and Outputs
Commercial and Industrial Temperature Ranges
4-Megabit
(512K x 8)
3-volt Only
256-Byte Sector
Flash Memory
Description
The AT29LV040A is a 3-volt only in-system Flash Programmable and Erasable Read
Only Memory (PEROM). Its 4 megabits of memory is organized as 524,288 words by
8 bits. Manufactured with Atmel’s advanced nonvolatile CMOS EEPROM technology,
the device offers access times to 200 ns, and a low 54 mW power dissipation. When
the device is deselected, the CMOS standby current is less than 40=µA. The device
PLCC Top View
CE
Chip Enable
OE
Output Enable
WE
Write Enable
I/O0 - I/O7
Data Inputs/Outputs
NC
No Connect
A7
A6
A5
A4
A3
A2
A1
A0
I/O0
4
3
2
1
32
31
30
Addresses
5
6
7
8
9
10
11
12
13
29
28
27
26
25
24
23
22
21
14
15
16
17
18
19
20
A0 - A18
A14
A13
A8
A9
A11
OE
A10
CE
I/O7
I/O1
I/O2
GND
I/O3
I/O4
I/O5
I/O6
Function
A12
A15
A16
A18
VCC
WE
A17
Pin Configurations
Pin Name
AT29LV040A
TSOP Top View
Type 1
A11
A9
A8
A13
A14
A17
WE
VCC
A18
A16
A15
A12
A7
A6
A5
A4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
OE
A10
CE
I/O7
I/O6
I/O5
I/O4
I/O3
GND
I/O2
I/O1
I/O0
A0
A1
A2
A3
Rev. 0334E–03/01
1
endurance is such that any sector can typically be written
to in excess of 10,000 times. The programming algorithm is
compatible with other devices in Atmel’s 3-volt only Flash
memories.
To allow for simple in-system reprogrammability, the
AT29LV040A does not require high input voltages for programming. Three-volt-only commands determine the operation of the device. Reading data out of the device is similar
to reading from an EPROM. Reprogramming the
AT29LV040A is performed on a sector basis; 256 bytes of
data are loaded into the device and then simultaneously
programmed.
During a reprogram cycle, the address locations and 256
bytes of data are captured at microprocessor speed and
internally latched, freeing the address and data bus for
other operations. Following the initiation of a program
cycle, the device will automatically erase the sector and
then program the latched data using an internal control
timer. The end of a program cycle can be detected by
DATA polling of I/O7. Once the end of a program cycle has
been detected, a new access for a read or program can
begin.
Block Diagram
Device Operation
READ: The AT29LV040A is accessed like an EPROM.
When CE and OE are low and WE is high, the data stored
at the memory location determined by the address pins is
asserted on the outputs. The outputs are put in the high
impedance state whenever CE or OE is high. This dual-line
control gives designers flexibility in preventing bus contention.
SOFTWARE DATA PROTECTION PROGRAMMING: The
AT29LV040A has 2048 individual sectors, each 256 bytes.
Using the software data protection feature, byte loads are
used to enter the 256 bytes of a sector to be programmed.
The AT29LV040A can only be programmed or reprogrammed using the software data protection feature. The
device is programmed on a sector basis. If a byte of data
within the sector is to be changed, data for the entire 256b y t e s e c t o r m u s t b e l o a d e d i n t o t h e d e v i c e . Th e
AT29LV040A automatically does a sector erase prior to
loading the data into the sector. An erase command is not
required.
Software data protection protects the device from inadvertent programming. A series of three program commands to
specific addresses with specific data must be presented to
the device before programming may occur. The same three
program commands must begin each program operation.
All software program commands must obey the sector program timing specifications. Power transitions will not reset
2
AT29LV040A
the software data protection feature, however the software
feature will guard against inadvertent program cycles during power transitions.
Any attempt to write to the device without the 3-byte command sequence will start the internal write timers. No data
will be written to the device; however, for the duration of
tWC, a read operation will effectively be a polling operation.
After the software data protection’s 3-byte command code
is given, a byte load is performed by applying a low pulse
on the WE or CE input with CE or WE low (respectively)
and OE high. The address is latched on the falling edge of
CE or WE, whichever occurs last. The data is latched by
the first rising edge of CE or WE.
The 256 bytes of data must be loaded into each sector. Any
byte that is not loaded during the programming of its sector
will be erased to read FFH. Once the bytes of a sector are
loaded into the device, they are simultaneously programmed during the internal programming period. After the
first data byte has been loaded into the device, successive
bytes are entered in the same manner. Each new byte to
be programmed must have its high to low transition on WE
(or CE) within 150 µs of the low to high transition of WE (or
CE) of the preceding byte. If a high to low transition is not
detected within 150 µs of the last low to high transition, the
load period will end and the internal programming period
AT29LV040A
will start. A8 to A18 specify the sector address. The sector
address must be valid during each high to low transition of
WE (or CE). A0 to A7 specify the byte address within the
sector. The bytes may be loaded in any order; sequential
loading is not required. Once a programming operation has
been initiated, and for the duration of tWC, a read operation
will effectively be a polling operation.
HARDWARE DATA PROTECTION: Hardware features
protect against inadvertent programs to the AT29LV040A
in the following ways: (a) VCC sense—if VCC is below 1.8V
(typical), the program function is inhibited; (b) VCC power on
delay—once V CC has reached the V CC sense level, the
device will automatically time out 10 ms (typical) before
programming; (c) Program inhibit—holding any one of OE
low, CE high or WE high inhibits program cycles; and
(d) Noise filter—pulses of less than 15 ns (typical) on the
WE or CE inputs will not initiate a program cycle.
INPUT LEVELS: While operating with a 3.3V ±10% power
supply, the address inputs and control inputs (OE, CE and
WE) may be driven from 0 to 5.5V without adversely affecting the operation of the device. The I/O lines can only be
driven from 0 to 3.6V.
PRODUCT IDENTIFICATION: The product identification
mode identifies the device and manufacturer as Atmel. It
may be accessed by hardware or software operation. The
hardware operation mode can be used by an external programmer to identify the correct programming algorithm for
the Atmel product. In addition, users may wish to use the
software product identification mode to identify the part (i.e.
using the device code), and have the system software use
the appropriate sector size for program operations. In this
manner, the user can have a common board design for
256K to 4-megabit densities and, with each density’s sector
size in a memory map, have the system software apply the
appropriate sector size.
For details, see Operating Modes (for hardware operation)
or Software Product Identification. The manufacturer and
device code is the same for both modes.
DATA POLLING: The AT29LV040A features DATA polling to indicate the end of a program cycle. During a program cycle an attempted read of the last byte loaded will
result in the complement of the loaded data on I/O7. Once
the program cycle has been completed, true data is valid
on all outputs and the next cycle may begin. DATA polling
may begin at any time during the program cycle.
TOGGLE BIT: In addition to DATA polling the
AT29LV040A provides another method for determining the
end of a program or erase cycle. During a program or erase
operation, successive attempts to read data from the
device will result in I/O6 toggling between one and zero.
Once the program cycle has completed, I/O6 will stop toggling and valid data will be read. Examining the toggle bit
may begin at any time during a program cycle.
OPTIONAL CHIP ERASE MODE: The entire device can
be erased by using a 6-byte software code. Please see
Software Chip Erase application note for details.
BO OT BLOCK PROGRAMMING LOCKO UT: The
AT29LV040A has two designated memory blocks that have
a programming lockout feature. This feature prevents programming of data in the designated block once the feature
has been enabled. Each of these blocks consists of 16K
bytes; the programming lockout feature can be set independently for either block. While the lockout feature does
not have to be activated, it can be activated for either or
both blocks.
These two 16K memory sections are referred to as boot
blocks. Secure code which will bring up a system can be
contained in a boot block. The AT29LV040A blocks are
located in the first 16K bytes of memory and the last 16K
bytes of memory. The boot block programming lockout feature can therefore support systems that boot from the lower
addresses of memory or the higher addresses. Once the
programming lockout feature has been activated, the data
in that block can no longer be erased or programmed; data
in other memory locations can still be changed through the
regular programming methods. To activate the lockout feature, a series of seven program commands to specific
addresses with specific data must be performed. Please
see Boot Block Lockout Feature Enable Algorithm.
If the boot block lockout feature has been activated on
either block, the chip erase function will be disabled.
BOOT BLOCK LOCKOUT DETECTION: A software
method is available to determine whether programming of
either boot block section is locked out. See Software Product Identification Entry and Exit sections. When the device
is in the software product identification mode, a read from
location 00002H will show if programming the lower
address boot block is locked out while reading location
FFFF2H will do so for the upper boot block. If the data is
FE, the corresponding block can be programmed; if the
data is FF, the program lockout feature has been activated
and the corresponding block cannot be programmed. The
software product identification exit mode should be used to
return to standard operation.
3
Absolute Maximum Ratings*
Temperature Under Bias................................ -55°C to +125°C
Storage Temperature ..................................... -65°C to +150°C
All Input Voltages (including NC Pins)
with Respect to Ground ...................................-0.6V to +6.25V
All Output Voltages
with Respect to Ground .............................-0.6V to VCC + 0.6V
Voltage on A9 (including NC Pins)
with Respect to Ground ...................................-0.6V to +13.5V
4
AT29LV040A
*NOTICE:
Stresses beyond those listed under “Absolute
Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and
functional operation of the device at these or any
other conditions beyond those indicated in the
operational sections of this specification is not
implied. Exposure to absolute maximum rating
conditions for extended periods may affect
device reliability.
AT29LV040A
DC and AC Operating Range
Operating
Temperature (Case)
AT29LV040A-25
0°C - 70°C
0°C - 70°C
-40°C - 85°C
-40°C - 85°C
3.3V ± 0.3V
3.3V ± 0.3V
Com.
Ind.
(1)
VCC Power Supply
Note:
AT29LV040A-20
1. After power is applied and VCC is at the minimum specified data sheet value, the system should wait 20 ms before an operational mode is started.
Operating Modes
Mode
CE
OE
WE
Ai
I/O
Read
VIL
VIL
VIH
Ai
DOUT
Program(2)
VIL
VIH
VIL
Ai
DIN
X
High Z
Standby/Write Inhibit
(1)
VIH
X
X
Program Inhibit
X
X
VIH
Program Inhibit
X
VIL
X
Output Disable
X
VIH
X
VIL
VIL
VIH
High Z
Product Identification
Hardware
A1 - A18 = VIL, A9 = VH(3), A0 = VIL
Manufacturer Code(4)
A1 - A18 = VIL, A9 = VH(3), A0 = VIH
Device Code(4)
Software(5)
Notes:
A0 = VI
Manufacturer Code(4)
A0 = VIH
Device Code(4)
1. X can be VIL or VIH.
2. Refer to AC Programming Waveforms.
3. VH = 12.0V ± 0.5V.
4. Manufacturer Code: 1F, Device Code: C4.
5. See details under Software Product Identification Entry/Exit.
DC Characteristics
Symbol
Parameter
Condition
ILI
Input Load Current
ILO
Min
Max
Units
VIN = 0V to VCC
1
µA
Output Leakage Current
VI/O = 0V to VCC
1
µA
Com.
40
ISB1
VCC Standby Current CMOS
CE = VCC - 0.3V to VCC
µA
Ind.
50
µA
ISB2
VCC Standby Current TTL
CE = 2.0V to VCC
1
mA
ICC
VCC Active Current
f = 5 MHz; IOUT = 0 mA; VCC = 3.6V
15
mA
VIL
Input Low Voltage
0.6
V
VIH
Input High Voltage
VOL
Output Low Voltage
IOL = 1.6 mA; VCC = 3.0V
VOH
Output High Voltage
IOH = -100 µA; VCC = 3.0V
2.0
V
.45
2.4
V
V
5
AC Read Characteristics
AT29LV040A-20
Symbol
Parameter
tACC
Address to Output Delay
CE to Output Delay
tCE
(1)
tOE
(2)
Min
AT29LV040A-25
Max
Min
Max
Units
200
250
ns
200
250
ns
OE to Output Delay
0
100
0
120
ns
tDF(3)(4)
CE or OE to Output Float
0
50
0
60
ns
tOH
Output Hold from OE, CE or Address,
whichever occurred first
0
0
ns
AC Read Waveforms(1)(2)(3)(4)
Notes:
1.
CE may be delayed up to tACC - tCE after the address transition without impact on tACC.
2.
OE may be delayed up to tCE - tOE after the falling edge of CE without impact on tCE or by tACC - tOE after an address change
without impact on tACC.
3.
tDF is specified from OE or CE whichever occurs first (CL = 5 pF).
4.
This parameter is characterized and is not 100% tested.
Input Test Waveforms and
Measurement Level
Output Test Load
tR, tF < 5 ns
Pin Capacitance
f = 1 MHz, T = 25°C(1)
Symbol
Typ
Max
Units
Conditions
CIN
4
6
pF
VIN = 0V
COUT
8
12
pF
VOUT = 0V
Note:
6
1. These parameters are characterized and not 100% tested.
AT29LV040A
AT29LV040A
AC Byte Load Characteristics
Symbol
Parameter
Min
Max
Units
tAS, tOES
Address, OE Set-up Time
10
ns
tAH
Address Hold Time
100
ns
tCS
Chip Select Set-up Time
0
ns
tCH
Chip Select Hold Time
0
ns
tWP
Write Pulse Width (WE or CE)
200
ns
tDS
Data Set-up Time
100
ns
tDH, tOEH
Data, OE Hold Time
10
ns
tWPH
Write Pulse Width High
200
ns
AC Byte Load Waveforms(1)(2)
WE Controlled
CE Controlled
Notes:
1.
The 3-byte address and data commands shown on the next page must be applied prior to byte loads.
2.
A complete sector (256 bytes) should be loaded using these waveforms shown in these byte load waveform diagrams.
7
Program Cycle Characteristics
Symbol
Parameter
Min
Max
Units
tWC
Write Cycle Time
20
ms
tAS
Address Set-up Time
10
ns
tAH
Address Hold Time
100
ns
tDS
Data Set-up Time
100
ns
tDH
Data Hold Time
10
ns
tWP
Write Pulse Width
200
ns
tBLC
Byte Load Cycle Time
tWPH
Write Pulse Width High
150
200
µs
ns
Software Protected Program Waveform
Notes:
1. OE must be high when WE and CE are both low.
2. A8 through A18 must specify the sector address during each high to low transition of WE (or CE) after the software code has
been entered.
3. All words that are not loaded within the sector being programmed will be indeterminate.
Programming Algorithm(1)
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
8
LOAD DATA A0
TO
ADDRESS 5555
WRITES ENABLED
LOAD DATA
TO
SECTOR (256 BYTES)(3)
ENTER DATA
PROTECT STATE(2)
AT29LV040A
Notes for software program code:
1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. Data Protect state will be re-activated at end of program
cycle.
3. 256 bytes of data MUST BE loaded.
AT29LV040A
Data Polling Characteristics(1)
Symbol
Parameter
Min
tDH
Data Hold Time
10
ns
tOEH
OE Hold Time
10
ns
Max
(2)
tOE
OE to Output Delay
tWR
Write Recovery Time
Notes:
Typ
Units
ns
0
ns
1. These parameters are characterized and not 100% tested.
2. See tOE spec in AC Read Characteristics.
Data Polling Waveforms
Toggle Bit Characteristics(1)
Symbol
Parameter
Min
tDH
Data Hold Time
10
ns
tOEH
OE Hold Time
10
ns
(2)
tOE
OE to Output Delay
tOEHP
OE High Pulse
tWR
Notes:
Write Recovery Time
Typ
Max
Units
ns
150
ns
0
ns
1. These parameters are characterized and not 100% tested.
2. See tOE spec in AC Read Characteristics.
Toggling Bit Waveforms(1)(3)
Notes:
1.
Toggling either OE or CE or both OE and CE will operate toggle bit.
2.
Beginning and ending state of I/O6 will vary.
3.
Any address location may be used by the address should not vary.
9
Software Product Identification Entry(1)
LOAD DATA AA
TO
ADDRESS 5555
5. Manufacturer Code is 1F. The Device Code is C4.
Boot Block Lockout
Feature Enable Algorithm(1)
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 90
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
PAUSE 20 mS
LOAD DATA 80
TO
ADDRESS 5555
ENTER PRODUCT
IDENTIFICATION
MODE(2)(3)(5)
Software Product Identification Exit(1)
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 40
TO
ADDRESS 5555
LOAD DATA F0
TO
ADDRESS 5555
PAUSE 20 mS
LOAD DATA FF
TO
ADDRESS FFFFFH(3)
PAUSE 20 mS
PAUSE 20 mS
EXIT PRODUCT
IDENTIFICATION
MODE(4)
Notes for software product identification:
1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. A1 - A18 = VIL.
Manufacturer Code is read for A0 = VIL;
Device Code is read for A0 = VIH.
3. The device does not remain in identification mode if
powered down.
4. The device returns to standard operation mode.
10
LOAD DATA 00
TO
ADDRESS 00000H(2)
AT29LV040A
Notes for boot block lockout feature enable:
1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. Lockout feature set on lower address boot block.
3. Lockout feature set on higher address boot block.
AT29LV040A
Ordering Information
ICC (mA)
tACC
(ns)
Active
Standby
Ordering Code
Package
200
15
0.04
AT29LV040A-20TC
AT29LV040A-20JC
32T
32J
Commercial
(0° to 70°C)
15
0.05
AT29LV040A-20TI
AT29LV040A-20JI
32T
32J
Industrial
(-40° to 85°C)
15
0.04
AT29LV040A-25TC
AT29LV040A-25JC
32T
32J
Commercial
(0° to 70°C)
15
0.05
AT29LV040A-25TI
AT29LV040A-25JI
32T
32J
Industrial
(-40° to 85°C)
250
Operation Range
Package Type
32J
32-lead, Plastic J-leaded Chip Carrier (PLCC)
32T
32-Lead, Thin Small Outline Package (TSOP)
11
AT29LV040A
Packaging Information
32J, 32-lead, Plastic J-leaded Chip Carrier (PLCC)
Dimensions in Inches and (Millimeters)
JEDEC STANDARD MS-016 AE
32T, 32-Lead, Plastic Thin Small Outline Package
(TSOP)
Dimensions in Millimeters and (Inches)*
JEDEC OUTLINE MO-142 BD
.045(1.14) X 45˚
PIN NO. 1
IDENTIFY
.025(.635) X 30˚ - 45˚
.012(.305)
.008(.203)
.553(14.0)
.547(13.9)
.595(15.1)
.585(14.9)
.032(.813)
.026(.660)
.050(1.27) TYP
.300(7.62) REF
.430(10.9)
.390(9.90)
AT CONTACT
POINTS
INDEX
MARK
.530(13.5)
.490(12.4)
18.5(.728)
18.3(.720)
.021(.533)
.013(.330)
.030(.762)
.015(.381)
.095(2.41)
.060(1.52)
.140(3.56)
.120(3.05)
0.50(.020)
BSC
7.50(.295)
REF
0.25(.010)
0.15(.006)
8.20(.323)
7.80(.307)
.022(.559) X 45˚ MAX (3X)
.453(11.5)
.447(11.4)
.495(12.6)
.485(12.3)
20.2(.795)
19.8(.780)
1.20(.047) MAX
0.15(.006)
0.05(.002)
0
5 REF
0.20(.008)
0.10(.004)
0.70(.028)
0.50(.020)
12
Atmel Headquarters
Atmel Operations
Corporate Headquarters
Atmel Colorado Springs
2325 Orchard Parkway
San Jose, CA 95131
TEL (408) 441-0311
FAX (408) 487-2600
Europe
1150 E. Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906
TEL (719) 576-3300
FAX (719) 540-1759
Atmel Rousset
Atmel SarL
Route des Arsenaux 41
Casa Postale 80
CH-1705 Fribourg
Switzerland
TEL (41) 26-426-5555
FAX (41) 26-426-5500
Asia
Atmel Asia, Ltd.
Room 1219
Chinachem Golden Plaza
77 Mody Road Tsimhatsui
East Kowloon
Hong Kong
TEL (852) 2721-9778
FAX (852) 2722-1369
Japan
Zone Industrielle
13106 Rousset Cedex
France
TEL (33) 4-4253-6000
FAX (33) 4-4253-6001
Atmel Smart Card ICs
Scottish Enterprise Technology Park
East Kilbride, Scotland G75 0QR
TEL (44) 1355-357-000
FAX (44) 1355-242-743
Atmel Grenoble
Avenue de Rochepleine
BP 123
38521 Saint-Egreve Cedex
France
TEL (33) 4-7658-3000
FAX (33) 4-7658-3480
Atmel Japan K.K.
9F, Tonetsu Shinkawa Bldg.
1-24-8 Shinkawa
Chuo-ku, Tokyo 104-0033
Japan
TEL (81) 3-3523-3551
FAX (81) 3-3523-7581
Fax-on-Demand
e-mail
North America:
1-(800) 292-8635
[email protected]
International:
1-(408) 441-0732
http://www.atmel.com
Web Site
BBS
1-(408) 436-4309
© Atmel Corporation 2001.
Atmel Corporation makes no warranty for the use of its products, other than those expressly contained in the Company’s standard warranty
which is detailed in Atmel’s Terms and Conditions located on the Company’s web site. The Company assumes no responsibility for any errors
which may appear in this document, reserves the right to change devices or specifications detailed herein at any time without notice, and does
not make any commitment to update the information contained herein. No licenses to patents or other intellectual property of Atmel are granted
by the Company in connection with the sale of Atmel products, expressly or by implication. Atmel’s products are not authorized for use as critical
components in life support devices or systems.
Marks bearing
®
and/or
™
are registered trademarks of Atmel Corporation.
Terms and product names in this document may be trademarks of others.
Printed on recycled paper.
0334E–03/01/xM