Features • Single Voltage Operation • • • • • • • • • – 5V Read – 5V Reprogramming Fast Read Access Time - 50 ns Internal Program Control and Timer 8K Bytes Boot Block With Lockout Fast Erase Cycle Time - 10 seconds Byte-by-Byte Programming - 10 µs/Byte Hardware Data Protection DATA Polling For End Of Program Detection Low Power Dissipation – 30 mA Active Current – 100 µA CMOS Standby Current Typical 10,000 Write Cycles 512K (64K x 8) 5-volt Only Flash Memory Description The AT49F512 is a 5-volt-only in-system programmable and erasable Flash Memory. Its 512K of memory is organized as 65,536 words by 8 bits. Manufactured with Atmel’s advanced nonvolatile CMOS technology, the devices offer access times to 50 ns with a power dissipation of just 165 mW over the commercial temperature range. When the device is deselected, the CMOS standby current is less than 100 µA. To allow for simple in-system reprogrammability, the AT49F512 does not require high input voltages for programming. Five-volt-only commands determine the read and programming operation of the device. Reading data out of the device is similar to reading from an EPROM. Reprogramming the AT49F512 is performed by erasing the entire 512K of memory and then programming on a byte by byte basis. The typical byte programming time is a fast 10 µs. The end of a program cycle can be optionally (continued) Pin Configurations Addresses CE Chip Enable OE Output Enable WE Write Enable I/O0 - I/O7 Data Inputs/Outputs NC No Connect NC NC A15 A12 A7 A6 A5 A4 A3 A2 A1 A0 I/O0 I/O1 I/O2 GND VSOP Top View (8 x 14 mm) or TSOP Top View (8 x 20 mm) Type 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 VCC WE NC A14 A13 A8 A9 A11 OE A10 CE I/O7 I/O6 I/O5 I/O4 I/O3 512K (64K x 8) 5-volt Only CMOS Flash Memory PLCC Top View OE A10 CE I/O7 I/O6 I/O5 I/O4 I/O3 GND I/O2 I/O1 I/O0 A0 A1 A2 A3 A12 A15 NC NC VCC WE NC A11 A9 A8 A13 A14 NC WE VCC NC NC A15 A12 A7 A6 A5 A4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A7 A6 A5 A4 A3 A2 A1 A0 I/O0 4 3 2 1 32 31 30 A0 - A15 DIP Top View 5 6 7 8 9 10 11 12 13 29 28 27 26 25 24 23 22 21 14 15 16 17 18 19 20 Function A14 A13 A8 A9 A11 OE A10 CE I/O7 Rev. 1027D–04/99 I/O1 I/O2 GND I/O3 I/O4 I/O5 I/O6 Pin Name AT49F512 1 detected by the DATA polling feature. Once the end of a byte program cycle has been detected, a new access for a read or program can begin. The typical number of program and erase cycles is in excess of 10,000 cycles. The optional 8K bytes boot block section includes a reprogramming write lock out feature to provide data integrity. The boot sector is designed to contain user secure code, and when the feature is enabled, the boot sector is permanently protected from being reprogrammed. Block Diagram FFFFH 2000H 1FFFH 0000H Device Operation READ: The AT49F512 is accessed like an EPROM. When CE and OE are low and WE is high, the data stored at the memory location determined by the address pins is asserted on the outputs. The outputs are put in the high impedance state whenever CE or OE is high. This dual-line control gives designers flexibility in preventing bus contention. ERASURE: Before a byte can be reprogrammed, the 64K bytes memory array (or 56K bytes if the boot block featured is used) must be erased. The erased state of the memory bits is a logical “1”. The entire device can be erased at one time by using a 6-byte software code. The chip erase code consists of 6-byte load commands to specific address locations with a specific data pattern (please refer to the Chip Erase Cycle Waveforms). After the chip erase has been initiated, the device will internally time the erase operation so that no external clocks are required. The maximum time needed to erase the whole chip is tEC. If the boot block lockout feature has been enabled, the data in the boot sector will not be erased. BYTE PROGRAMMING: Once the memory array is erased, the device is programmed (to a logical “0”) on a byte-by-byte basis. Please note that a data “0” cannot be programmed back to a “1”; only erase operations can convert “0”s to “1”s. Programming is accomplished via the internal device command register and is a 4 bus cycle operation (please refer to the Command Definitions table). The device will automatically generate the required internal program pulses. The program cycle has addresses latched on the falling edge of WE or CE, whichever occurs last, and the data 2 AT49F512 latched on the rising edge of WE or CE, whichever occurs first. Programming is completed after the specified tBP cycle time. The DATA polling feature may also be used to indicate the end of a program cycle. BOOT BLOCK PROGRAMMING LOCKOUT: The device has one designated block that has a programming lockout feature. This feature prevents programming of data in the designated block once the feature has been enabled. The size of the block is 8K bytes. This block, referred to as the boot block, can contain secure code that is used to bring up the system. Enabling the lockout feature will allow the boot code to stay in the device while data in the rest of the device is updated. This feature does not have to be activated; the boot block’s usage as a write protected region is optional to the user. The address range of the boot block is 0000H to 1FFFH. Once the feature is enabled, the data in the boot block can no longer be erased or programmed. Data in the main memory block can still be changed through the regular programming method. To activate the lockout feature, a series of six program commands to specific addresses with specific data must be performed. Please refer to the Command Definitions table. BOOT BLOCK LOCKOUT DETECTION: A software method is available to determine if programming of the boot block section is locked out. When the device is in the software product identification mode (see Software Product Identification Entry and Exit sections) a read from address location 00002H will show if programming the boot block is locked out. If the data on I/O0 is low, the boot block can be programmed; if the data on I/O0 is high, the program lock- AT49F512 out feature has been activated and the block cannot be programmed. The software product identification code should be used to return to standard operation. PRODUCT IDENTIFICATION: The product identification mode identifies the device and manufacturer as Atmel. It may be accessed by hardware or software operation. The hardware operation mode can be used by an external programmer to identify the correct programming algorithm for the Atmel product. For details, see Operating Modes (for hardware operation) or Software Product Identification. The manufacturer and device code is the same for both modes. DATA POLLING: The AT49F512 features DATA polling to indicate the end of a program cycle. During a program cycle an attempted read of the last byte loaded will result in the complement of the loaded data on I/O7. Once the program cycle has been completed, true data is valid on all outputs and the next cycle may begin. DATA polling may begin at any time during the program cycle. TOGGLE BIT: In addition to DATA polling the AT49F512 provides another method for determining the end of a program or erase cycle. During a program or erase operation, successive attempts to read data from the device will result in I/O6 toggling between one and zero. Once the program cycle has completed, I/O6 will stop toggling and valid data will be read. Examining the toggle bit may begin at any time during a program cycle. HARDWARE DATA PROTECTION: Hardware features protect against inadvertent programs to the AT49F512 in the following ways: (a) VCC sense: if VCC is below 3.8V (typical), the program function is inhibited. (b) Program inhibit: holding any one of OE low, CE high or WE high inhibits program cycles. (c) Noise filter: Pulses of less than 15 ns (typical) on the WE or CE inputs will not initiate a program cycle. Command Definition (in Hex) Command Sequence Bus Cycles 1st Bus Cycle Addr Data 2nd Bus Cycle 3rd Bus Cycle 4th Bus Cycle 6th Bus Cycle Addr Data Addr Data Addr Data Addr Data Addr Data 2AAA 55 5555 10 2AAA 55 5555 40 Read 1 Addr DOUT Chip Erase 6 5555 AA 2AAA 55 5555 80 5555 AA Byte Program 4 5555 AA 2AAA 55 5555 A0 Addr DIN Boot Block Lockout(1) 6 5555 AA 2AAA 55 5555 80 5555 AA Product ID Entry 3 5555 AA 2AAA 55 5555 90 Product ID Exit(2) 3 5555 AA 2AAA 55 5555 F0 Product ID Exit(2) 1 XXXX F0 Notes: 5th Bus Cycle 1. The 8K byte boot sector has the address range 0000H to 1FFFH. 2. Either one of the Product ID exit commands can be used. Absolute Maximum Ratings* Temperature Under Bias ................................ -55°C to +125°C Storage Temperature ..................................... -65°C to +150°C All Input Voltages (including NC pins) with Respect to Ground ...................................-0.6V to +6.25V All Output Voltages with Respect to Ground .............................-0.6V to VCC + 0.6V *NOTICE: Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Voltage on OE with Respect to Ground ...................................-0.6V to +13.5V 3 DC and AC Operating Range Com. Operating Temperature (Case) Ind. VCC Power Supply AT49F512-50 AT49F512-70 AT49F512-90 0°C - 70°C 0°C - 70°C 0°C - 70°C -40°C - 85°C -40°C - 85°C -40°C - 85°C 5V ± 10% 5V ± 10% 5V ± 10% Operating Modes Mode CE OE WE Ai I/O Read VIL VIL VIH Ai DOUT Program(2) VIL VIH VIL Ai DIN X High Z Standby/Write Inhibit (1) VIH X X Program Inhibit X X VIH Program Inhibit X VIL X Output Disable X VIH X VIL VIL VIH High Z Product Identification Hardware A1 - A15 = VIL, A9 = VH, A0 = VIL(3) Manufacturer Code(4) A1 - A15 = VIL, A9 = VH, A0 = VIH(3) Device Code(4) Software(5) Notes: A0 = VIL, A1 - A15 = VIL Manufacturer Code(4) A0 = VIH, A1 - A15 = VIL Device Code(4) 1. X can be VIL or VIH. 2. Refer to AC Programming Waveforms. 3. VH = 12.0V ± 0.5V. 4. Manufacturer Code: 1FH, Device Code: 03H 5. See details under Software Product Identification Entry/Exit. DC Characteristics Symbol Parameter Condition ILI Input Load Current ILO Max Units VIN = 0V to VCC 10 µA Output Leakage Current VI/O = 0V to VCC 10 µA Com. 100 µA ISB1 VCC Standby Current CMOS CE = VCC - 0.3V to VCC Ind. 300 µA ISB2 VCC Standby Current TTL CE = 2.0V to VCC 3 mA ICC(1) Com. 30 mA VCC Active Current f = 5 MHz; IOUT = 0 mA Ind. 40 mA VIL Input Low Voltage 0.8 V VIH Input High Voltage VOL Output Low Voltage IOL = 2.1 mA VOH1 Output High Voltage IOH = -400 µA 2.4 V VOH2 Output High Voltage CMOS IOH = -100 µA; VCC = 4.5V 4.2 V Note: 4 Min 2.0 1. In the erase mode, ICC is 90 mA. AT49F512 V 0.45 V AT49F512 AC Read Characteristics Symbol Parameter tACC tCE AT49F512-50 AT49F512-70 AT49F512-90 Min Min Min Max Max Max Units Address to Output Delay 50 70 90 ns (1) CE to Output Delay 50 70 90 ns (2) OE to Output Delay 30 35 0 40 ns 25 0 25 ns tOE tDF(3)(4) CE or OE to Output Float 0 tOH Output Hold from OE, CE or Address, whichever occurred first 0 25 0 0 0 ns AC Read Waveforms(1)(2)(3)(4) Notes: 1. CE may be delayed up to tACC - tCE after the address transition without impact on tACC. 2. OE may be delayed up to tCE - tOE, after the falling edge of CE without impact on tCE or by tACC - tOE after an address change without impact on tACC. 3. tDF is specified from OE or CE whichever occurs first (CL = 5 pF). 4. This parameter is characterized and is not 100% tested. Input Test Waveforms and Measurement Level Output Test Load tR, tF < 5 ns Pin Capacitance f = 1 MHz, T= 25°C(1) Symbol Typ Max Units Conditions CIN 4 6 pF VIN = 0V COUT 8 12 pF VOUT = 0V Note: 1. This parameter is characterized and is not 100% tested. 5 AC Word Load Characteristics Symbol Parameter Min tAS, tOES Address, OE Set-up Time 0 ns tAH Address Hold Time 50 ns tCS Chip Select Set-up Time 0 ns tCH Chip Select Hold Time 0 ns tWP Write Pulse Width (WE or CE) 90 ns tDS Data Set-up Time 50 ns tDH, tOEH Data, OE Hold Time 0 ns tWPH Write Pulse Width High 90 ns AC Byte Load Waveforms WE Controlled CE Controlled 6 AT49F512 Max Units AT49F512 Program Cycle Characteristics Symbol Parameter Min Typ Max Units tBP Byte Programming Time 10 50 µs tAS Address Set-up Time 0 ns tAH Address Hold Time 50 ns tDS Data Set-up Time 50 ns tDH Data Hold Time 0 ns tWP Write Pulse Width 90 ns tWPH Write Pulse Width High 90 ns tEC Erase Cycle Time 10 seconds Program Cycle Waveforms PROGRAM CYCLE OE CE t t WP t WPH BP WE t A0-A15 t AH AS t 5555 5555 2AAA t DATA DH ADDRESS DS 55 AA INPUT DATA A0 Chip Erase Cycle Waveforms OE CE t t WP WPH WE t A0-A15 AS t t AH 5555 Note: 5555 5555 2AAA t DATA DH 5555 2AAA t DS AA 55 80 AA 55 10 BYTE 0 BYTE 1 BYTE 2 BYTE 3 BYTE 4 BYTE 5 EC OE must be high only when WE and CE are both low. 7 Data Polling Characteristics(1) Symbol Parameter Min tDH Data Hold Time tOEH OE Hold Time Max OE to Output Delay tWR Write Recovery Time Units 10 ns 10 ns (2) tOE Notes: Typ ns 0 ns 1. These parameters are characterized and not 100% tested. 2. See tOE spec in AC Read Characteristics. Data Polling Waveforms WE CE tOEH OE tDH tOE A0-A15 tWR HIGH Z I/O7 An An An An An Toggle Bit Characteristics(1) Symbol Parameter tDH Data Hold Time 10 ns tOEH OE Hold Time 10 ns tOE OE to Output Delay(2) tOEHP OE High Pulse tWR Write Recovery Time Notes: Min Typ Max Units ns 150 ns 0 ns 1. These parameters are characterized and not 100% tested. 2. See tOE spec in AC Read Characteristics. Toggle Bit Waveforms(1)(2)(3) Notes: 8 1. Toggling either OE or CE or both OE and CE will operate toggle bit. The tOEHP specification must be met by the toggling input(s) 2. Begining and ending state of I/O6 will vary. 3. Any address location may be used but the address should not vary. AT49F512 AT49F512 Software Product Identification Entry(1) LOAD DATA AA TO ADDRESS 5555 Boot Block Lockout Enable Algorithm(1) LOAD DATA AA TO ADDRESS 5555 LOAD DATA 55 TO ADDRESS 2AAA LOAD DATA 55 TO ADDRESS 2AAA LOAD DATA 90 TO ADDRESS 5555 LOAD DATA 80 TO ADDRESS 5555 ENTER PRODUCT IDENTIFICATION MODE(2)(3)(5) LOAD DATA AA TO ADDRESS 5555 Software Product Identifcation Exit(1) LOAD DATA AA TO ADDRESS 5555 OR LOAD DATA 55 TO ADDRESS 2AAA LOAD DATA 55 TO ADDRESS 2AAA LOAD DATA F0 TO ANY ADDRESS LOAD DATA 40 TO ADDRESS 5555 EXIT PRODUCT IDENTIFICATION MODE(4) LOAD DATA F0 TO ADDRESS 5555 PAUSE 1 second(2) Notes: EXIT PRODUCT IDENTIFICATION MODE(4) Notes: 1. Data Format: I/O7 - I/O0 (Hex); Address Format: A14 - A0 (Hex). 2. Boot block lockout feature enabled. 1. Data Format: I/O7 - I/O0 (Hex); Address Format: A14 - A0 (Hex). 2. A1 - A15 = VIL. Manufacture Code is read for A0 = VIL; Device Code is read for A0 = VIH. 3. The device does not remain in identification mode if powered down. 4. The device returns to standard operation mode. 5. Manufacturer Code: 1FH Device Code: 03H 9 Ordering Information(1) tACC (ns) 50 70 90 Note: Active 30 ICC (mA) Standby 0.1 Ordering Code Package AT49F512-50JC AT49F512-50PC AT49F512-50TC AT49F512-50VC 32J 32P6 32T 32V Commercial (0° to 70°C) 40 0.3 AT49F512-50JI AT49F512-50PI AT49F512-50TI AT49F512-50VI 32J 32P6 32T 32V Industrial (-40° to 85°C) 30 0.1 AT49F512-70JC AT49F512-70PC AT49F512-70TC AT49F512-70VC 32J 32P6 32T 32V Commercial (0° to 70°C) 40 0.3 AT49F512-70JI AT49F512-70PI AT49F512-70TI AT49F512-70VI 32J 32P6 32T 32V Industrial (-40° to 85°C) 30 0.1 AT49F512-90JC AT49F512-90PC AT49F512-90TC AT49F512-90VC 32J 32P6 32T 32V Commercial (0° to 70°C) 40 0.3 AT49F512-90JI AT49F512-90PI AT49F512-90TI AT49F512-90VI 32J 32P6 32T 32V Industrial (-40° to 85°C) 1. The AT49F512 has as optional boot block feature. The part number shown in the Ordering Information table is for devices with the boot block in the lower address range (i.e., 0000H to 1FFFH). Users requiring the boot block to be in the higher address range should contact Atmel. Package Type 32J 32-lead, Plastic, J-leaded Chip Carrier Package (PLCC) 32P6 32-lead, 0.600" Wide, Plastic Dual Inline Package (PDIP) 32T 32-lead, Thin Small Outline Package (TSOP) (8 x 20 mm) 32V 32-lead, Thin Small Outline Package (VSOP) (8 x 14 mm) 10 Operation Range AT49F512 AT49F512 Packaging Information 32J, 32-lead, Plastic J-leaded Chip Carrier (PLCC) Dimensions in Inches and (Millimeters) JEDEC STANDARD MS-016 AE .045(1.14) X 45˚ PIN NO. 1 IDENTIFY .050(1.27) TYP 1.67(42.4) 1.64(41.7) .025(.635) X 30˚ - 45˚ .012(.305) .008(.203) .553(14.0) .547(13.9) .595(15.1) .585(14.9) .032(.813) .026(.660) 32P6, 32-lead, 0.600" Wide, Plastic Dual Inline Package (PDIP) Dimensions in Inches and (Millimeters) .300(7.62) REF .430(10.9) .390(9.90) AT CONTACT POINTS .530(13.5) .490(12.4) .566(14.4) .530(13.5) .021(.533) .013(.330) .030(.762) .015(.381) .095(2.41) .060(1.52) .140(3.56) .120(3.05) .022(.559) X 45˚ MAX (3X) .220(5.59) MAX .005(.127) MIN SEATING PLANE INDEX MARK .065(1.65) .015(.381) .022(.559) .014(.356) .161(4.09) .125(3.18) .065(1.65) .041(1.04) .110(2.79) .090(2.29) .630(16.0) .590(15.0) 0 REF 15 .012(.305) .008(.203) 32T, 32-lead, Plastic Thin Small Outline Package (TSOP) Dimensions in Millimeters and (Inches)* .090(2.29) MAX 1.500(38.10) REF .453(11.5) .447(11.4) .495(12.6) .485(12.3) .690(17.5) .610(15.5) 32V, 32-lead, Plastic Thin Small Outline Package (VSOP) Dimensions in Millimeters and (Inches)* INDEX MARK 18.5(.728) 18.3(.720) 0.50(.020) BSC PIN 1 7.50(.295) REF 20.2(.795) 19.8(.780) 12.5(.492) 12.3(.484) 0.50(.020) BSC 0.25(.010) 0.15(.006) 8.20(.323) 7.80(.307) 7.50(.295) REF 0.25(.010) 0.15(.006) 8.10(.319) 7.90(.311) 1.20(.047) MAX 0.15(.006) 0.05(.002) 14.2(.559) 13.8(.543) 1.20(.047) MAX 0.15(.006) 0.05(.002) 0 5 REF 0.20(.008) 0.10(.004) 0.70(.028) 0.50(.020) *Controlling dimensions: millimeters 0 5 REF 0.20(.008) 0.10(.004) 0.70(.028) 0.50(.020) *Controlling dimensions: millimeters 11 Atmel Headquarters Atmel Operations Corporate Headquarters Atmel Colorado Springs 2325 Orchard Parkway San Jose, CA 95131 TEL (408) 441-0311 FAX (408) 487-2600 Europe 1150 E. Cheyenne Mtn. Blvd. Colorado Springs, CO 80906 TEL (719) 576-3300 FAX (719) 540-1759 Atmel Rousset Atmel U.K., Ltd. Coliseum Business Centre Riverside Way Camberley, Surrey GU15 3YL England TEL (44) 1276-686-677 FAX (44) 1276-686-697 Zone Industrielle 13106 Rousset Cedex France TEL (33) 4-4253-6000 FAX (33) 4-4253-6001 Asia Atmel Asia, Ltd. Room 1219 Chinachem Golden Plaza 77 Mody Road Tsimhatsui East Kowloon Hong Kong TEL (852) 2721-9778 FAX (852) 2722-1369 Japan Atmel Japan K.K. 9F, Tonetsu Shinkawa Bldg. 1-24-8 Shinkawa Chuo-ku, Tokyo 104-0033 Japan TEL (81) 3-3523-3551 FAX (81) 3-3523-7581 Fax-on-Demand North America: 1-(800) 292-8635 International: 1-(408) 441-0732 e-mail [email protected] Web Site http://www.atmel.com BBS 1-(408) 436-4309 © Atmel Corporation 1999. Atmel Cor poration makes no warranty for the use of its products, other than those expressly contained in the Company’s standard warranty which is detailed in Atmel’s Terms and Conditions located on the Company’s web site. The Company assumes no responsibility for any errors which may appear in this document, reserves the right to change devices or specifications detailed herein at any time without notice, and does not make any commitment to update the information contained herein. No licenses to patents or other intellectual proper ty of Atmel are granted by the Company in connection with the sale of Atmel products, expressly or by implication. Atmel’s products are not authorized for use as critical components in life suppor t devices or systems. Marks bearing ® and/or ™ are registered trademarks and trademarks of Atmel Corporation. Terms and product names in this document may be trademarks of others. Printed on recycled paper. 1027D–04/99/xM