ETC BP5710-1

BP5710-1
AC/DC converter
AC100V
C100V input, 12V/350mA output
Dimension(Unit : mm)
Absolute Maximum Ratings
V
mApk
kV
°C
°C
Vrms
15.0MAX.
36.0MAX.
DC
Mark Side
Unit
170
350
2
−20 ∼ +80
−25 ∼ +85
1800
24.0MAX.
Limits
IEC61000-4-2 Highest level 1
1
4±1.0
Parameter
Symbol
Input voltage
Vi
Output current
Io
ESD endurance
Vsurge
Operating temperature range
Topr
Storage temperature range
Tstg
Voltage between 1&2 order
2
4
5
8
10 1 1
0.5±0.1
2sec
P= 2.54±0.2
0 . 2 5 ±0 . 0 5
1.3±0.2
5.25MAX.
5.5MAX
2.54×10=25.4
9.75MAX.
Electrical Characteristics
Unit
V
V
mA
V
V
Vp-p
%
MΩ
Conditions
DC(85∼115VAC)
Vi=141V, Io=350mA
Vi=141V
∗1
Vi=120∼162V, Io=350mA
Vi=141V, Io=0∼350mA ∗2
Vi=141V, Io=350mA
Vi=141V, Io=350mA
∗2
DC100V between 1&2 order
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Please refer to Load regulation, Conversion effciency.
Application circuit
BP5710-1
Be sure to use fuse for safety.
1 2
FL1
ZNR C1
C2
8
10 11
Output
12V
FUSE
D1
Input
AC100V
50Hz/60Hz
4 5
+
+
−
−
C3
Pin No.
1
2
3
4
5
6
7
8
9
10
11
C4
Function
Input terminal Vi(141VDC)
Input terminal Vi(141VDC)
Not used
COMMON (Primary)
COMMON (Primary)
Not used
Not used
COMMON (Secondary)
Not used
Capacitor connect
Output terminal Vo(12V)
C5
For acutual usage, Please kindly evaluate and confirm our part mounted in your product,
Especially, Please make sure to confirm whether the load current exceed Max. rated current
by using the current probe.
Derating Curve
Output Current Io(mA)
Max.
162
13
350
0.3
0.3
−
−
−
Derating Curve
400
350
300
250
200
Operation Range
150
100
50
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Switching Frequency
Switching Frequency fsw(kHz)
Typ.
141
12
−
0.15
0.15
0.25
77
−
Switching Frequency
(Ta=25°C, Vi=141V)
600
500
400
300
200
100
0
0
100
90
80
70
60
50
40
30
20
10
0
0
External components setting
D1: Rectifier diode
FL1: For noise terminal
voltage reduction
ZNR: Varistor
In the absolute maximum ratings, the reverse peak voltage should be
400V or higher, the average rectifying current should be 0.5A or higher,
and the peak surge current should be 20A or higher.
(Full-wave rectifier can be used in our part.)
Please use the linefilter, if necessary.
Varistor must be used. It protects this part from lightning surge and
static electricity.
Conversion Efficiency
(Ta=25°C, Vi=141V)
50 100 150 200 250 300 350
Output Current Io(mA)
Load Regulation
Load Regulation
(Ta=25°C, Vi=141V)
14
Output Voltage Vo(V)
Please make sure to use quick acting fuse 0.5A
C1,2,4 : For noise terminal Capacitance(C1,2) : 0.1µF∼0.22µF, (C4): 4700pF degree
voltage reduction Rated voltage : 200V or higher. Film capacitor or ceramic capacitor.
Reduce the noise terminal voltage.The constant value should be evaluated
in the set.
Capacitance : 33µF∼330µF Rated voltage : 200V or higher
C3: Capacitor for input
voltage smoothing
C5: Capacitor for Output
Capacitance : 470µF∼1000µF Rated voltage : 25V or higher,
voltage smooting
ESR is 0.16Ω max. Ripple current is 0.58Arms above.
Output noise voltage is influenced.Please evaluate it in the actual set.
12
10
8
6
4
2
0
0
100 200 300 400 500 600 700
Output Current Io(mA)
Surface Temperature Rising
Surface Temperature Rising ∆T(°C)
FUSE: Fuse
50 100 150 200 250 300 350
Output Current Io(mA)
Conversion Efficiency
Conversion Efficiency η(%)
Symbol Min.
Parameter
Input voltage range
120
Vi
Output voltage
Vo
11
Output current
Io
0
Line regulation
Vr
−
Load regulation
Vl
−
Output ripple voltage
Vp
−
Power conversion efficiency
η
70
Isolation resistance
100
60
Surface Temperature Rising
(Ta=25°C, Vi=141V)
50
40
30
20
10
0
0
50
100 150 200 250 300 350
Output Current Io(mA)
1/2
Precautions on Use of ROHM Power Module
Safety Precautions
1) The products are designed and produced for application in ordinary electronic equipment (AV equipment,
OA equipment, telecommunication equipment, home appliances, amusement equipment etc.).
If the products are to be used in devices requiring extremely high reliability (medical equipment, transport
equipment, aircraft/spacecraft, nuclear power controllers, fuel controllers, car equipment including car
accessories, safety devices, etc.) and whose malfunction or operational error may endanger human life
and sufficient fail-safe measures, please consult with the Company's sales staff in advance. If product
malfunctions may result in serious damage, including that to human life, sufficient fail-safe measures
must be taken, including the following:
[a] Installation of protection circuits or other protective devices to improve system safety
[b] Installation of redundant circuits in the case of single-circuit failure
2) The products are designed for use in a standard environment and not in any special environments.
Application of the products in a special environment can deteriorate product performance. Accordingly,
verification and confirmation of product performance, prior to use, is recommended if used under the
following conditions:
[a] Use in various types of liquid, including water, oils, chemicals, and organic solvents
[b] Use outdoors where the products are exposed to direct sunlight, or in dusty places
[c] Use in places where the products are exposed to sea winds or corrosive gases, including
Cl2, H2S, NH3, SO2, and NO2
[d] Use in places where the products are exposed to static electricity or electromagnetic waves
[e] Use in proximity to heat-producing components, plastic cords, or othe flammable items
[f] Use involving sealing or coating the products with resin or other coating materials
[g] Use involving unclean solder or use of water or water-soluble cleaning agents for cleaning after
soldering
[h] Use of the products in places subject to dew condensation
3) The products are not radiation resistant.
4) The Company is not responsible for any problems resulting from use of the products under conditions not
recommended herein.
5) The Company should be notified of any product safety issues. Moreover, product safety issues should be
periodically monitored by the customer.
Precautions Regarding Application Example and External Circuits
1) If change is made to the constant of an external circuit, allow a sufficient margin due to variations of the
characteristics of the products and external components, including transient characteristics, as well as
static characteristics. Please be informed that the Company has not conducted investigations on whether
or not particular changes in the application examples or external circuits would result in the infringement
of patent rights of a third party.
2) The application examples, their constants, and other types of information contained herein are applicable
only when the products are used in accordance with standard methods.
Therefore, if mass production is intended, sufficient consideration to external conditions must be made.
Prohibitions Regarding Industrial Property
1) These Specifications contain information related to the Company’s industrial property. Any use of them
other than pertaining to the usage of appropriate products is not permitted. Duplication of these
Specifications and its disclosure to a third party without the Company’s permission is prohibited.
2) Information and data on products, including application examples, contained in these specifications are
simply for reference; the Company does not guarantee any industrial property rights, intellectual property
rights, or any other rights of a third party regarding this information or data. Accordingly, the Company
does not bear any responsibility for:
[a] infringement of the intellectual property rights of a third party
[b] any problems incurred by the use of the products listed herein.
3) The Company prohibits the purchaser of its products to exercise or use the intellectual property rights,
industrial property rights, or any other rights that either belong to or are controlled by the Company, other
than the right to use, sell, or dispose of the products.
2/2