ROHM BP5046

BP5046
AC/DC converter
AC220V input, −12V/200mA output
Dimension(Unit : mm)
Limits
Unit
Vi
Io
Vsurge
Topr
Tstg
−358
200
2
−25 ~ +80
−25 ~ +105
V
mApk
kV
°C
°C
9.1MAX.
35.0MAX.
Mark Side
Symbol
19.1MAX.
Parameter
Input voltage
Output voltage
ESD endurance
Operating temperature range
Strabe temperature range
1
4±1.0
Absolute Maximum Ratings
3
5
7
10
12
0.25±0.05
0.5±0.1
1.3±0.2
P=5.08±0.2
3.3MAX
4.45MAX.
4.65MAX.
2.54×11=27.94
Electrical Characteristics
Conditions
DC (187~276VAC)
Vi=−311V, Io=150mA
Vi=−311V
∗1
Vi=−358~−240V, Io=150mA
Vi=−311V, Io=0~150mA
Vi=−311V, Io=150mA ∗2
Vi=−311V, Io=200mA
Unit
V
V
mApk
V
V
Vp-p
%
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Spike noise is not included in output ripple voltage.
Application circuit
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
BP5046
Please note that pin No.12
side is input.
12
R1
10Ω1/4W
D1
Input
AC220V
50Hz/60Hz
ZNR −
+
C1
10µF/450V
7
5
3
1
FUSE
1A
C2
0.1µF
L1
1.5mH −
Output
−12V
Function
Output terminal Vo(−12V)
Not used
Coil connect
Not used
Coil connect
Not used
COMMON
Not used
Not used
N.C.
Not used
Input terminal Vi(−311VDC)
C3
+ 100µF/50V
Be sure to use fuse for safety.
Derating Curve
Derating Curve
300
Output Current Io(mA)
Max.
−358
−13.2
200
0.15
0.20
0.15
−
250
200
150
Operation Range
100
50
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Conversion Efficiency
Conversion Efficiency (%)
Typ.
−311
−12.5
−
0.04
0.10
0.05
72
100
90
80
70
60
50
40
30
20
10
0
0
Conversion Efficiency
(Ta=25°C, Vi=−311V)
50
100
150
Output Current Io(mA)
200
Load Regulation
Load Regulation
(Ta=25°C, Vi=−311V)
14
Output Voltage -Vo(V)
Symbol Min.
Parameter
Input voltage range
−240
Vi
Output voltage
−11.5
Vo
Output current
0
Io
Line regulation
−
Vr
Load regulation
−
Vl
Output ripple voltage
−
Vp
Power conversion efficiency
64
η
12
10
8
6
4
2
0
0
For acutual usage, Please kindly evaluate and confirm our part mounted in your product,
Especially, Please make sure to confirm whether the load current exceed Max. rated current
by using the current probe.
50
100 150 200 250 300 350
Output Current Io(mA)
Surface Temperature Rising
FUSE: Fuse
Please make sure to use quick acting fuse 1A
C1: Capacitor for input
voltage smoothing
Capacitance : 10~100µF Rated voltage : 450V or higher
Ripple current is 0.13Arms above.
C2: For noise terminal
voltage reduction
Capacitance : 0.1µF~0.22µF Rated voltage : 450V or higher
Film capacitor or ceramic capacitor. Reduce the noise terminal voltage.
The constant value should be evaluated in the set.
C3: Capacitor for Output
voltage smooting
Capacitance : 100µF~2200µF Rated voltage : 25V or higher,
ESR is 0.4Ω max. Ripple current is 0.25Arms above.
Output noise voltage is infulenced.Please evaluate it in the actual set.
In the absolute maximum ratings, the reverse peak voltage should be
800V or higher, the average rectifying current should be 0.5A or higher,
and the peak surge current should be 20A or higher.
(Full-wave rectifier can be used in out part.)
Coil for switching regulator. The inductance should be 1.5mH,
the rated direct current should be 0.3A above.
Otherwise heating or abnormal oscilation occurs.
D1: Rectifier diode
L1: Choke coil
R1: For noise terminal
voltage reduction
ZNR: Varistor
Temperature Rising ∆T(°C)
External components setting
40
35
30
25
20
15
10
5
0
Surface Temperature Rising
(Ta=25°C, Vi=−311V)
0
50
100
150
200
Output Current Io(mA)
250
10Ω~22Ω 1/4W
Reduce the noise terminal voltage.Please set it,if necessary.
The constant value should be evaluated in set.
Varistor must be used. It protects this part from lightning surge and static
electricity.
1/2
Precautions on Use of ROHM Power Module
Safety Precautions
1) The products are designed and produced for application in ordinary electronic equipment (AV equipment,
OA equipment, telecommunication equipment, home appliances, amusement equipment etc.).
If the products are to be used in devices requiring extremely high reliability (medical equipment, transport
equipment, aircraft/spacecraft, nuclear power controllers, fuel controllers, car equipment including car
accessories, safety devices, etc.) and whose malfunction or operational error may endanger human life
and sufficient fail-safe measures, please consult with the Company's sales staff in advance. If product
malfunctions may result in serious damage, including that to human life, sufficient fail-safe measures
must be taken, including the following:
[a] Installation of protection circuits or other protective devices to improve system safety
[b] Installation of redundant circuits in the case of single-circuit failure
2) The products are designed for use in a standard environment and not in any special environments.
Application of the products in a special environment can deteriorate product performance. Accordingly,
verification and confirmation of product performance, prior to use, is recommended if used under the
following conditions:
[a] Use in various types of liquid, including water, oils, chemicals, and organic solvents
[b] Use outdoors where the products are exposed to direct sunlight, or in dusty places
[c] Use in places where the products are exposed to sea winds or corrosive gases, including
Cl2, H2S, NH3, SO2, and NO2
[d] Use in places where the products are exposed to static electricity or electromagnetic waves
[e] Use in proximity to heat-producing components, plastic cords, or othe flammable items
[f] Use involving sealing or coating the products with resin or other coating materials
[g] Use involving unclean solder or use of water or water-soluble cleaning agents for cleaning after
soldering
[h] Use of the products in places subject to dew condensation
3) The products are not radiation resistant.
4) The Company is not responsible for any problems resulting from use of the products under conditions not
recommended herein.
5) The Company should be notified of any product safety issues. Moreover, product safety issues should be
periodically monitored by the customer.
Precautions Regarding Application Example and External Circuits
1) If change is made to the constant of an external circuit, allow a sufficient margin due to variations of the
characteristics of the products and external components, including transient characteristics, as well as
static characteristics. Please be informed that the Company has not conducted investigations on whether
or not particular changes in the application examples or external circuits would result in the infringement
of patent rights of a third party.
2) The application examples, their constants, and other types of information contained herein are applicable
only when the products are used in accordance with standard methods.
Therefore, if mass production is intended, sufficient consideration to external conditions must be made.
Prohibitions Regarding Industrial Property
1) These Specifications contain information related to the Company’s industrial property. Any use of them
other than pertaining to the usage of appropriate products is not permitted. Duplication of these
Specifications and its disclosure to a third party without the Company’s permission is prohibited.
2) Information and data on products, including application examples, contained in these specifications are
simply for reference; the Company does not guarantee any industrial property rights, intellectual property
rights, or any other rights of a third party regarding this information or data. Accordingly, the Company
does not bear any responsibility for:
[a] infringement of the intellectual property rights of a third party
[b] any problems incurred by the use of the products listed herein.
3) The Company prohibits the purchaser of its products to exercise or use the intellectual property rights,
industrial property rights, or any other rights that either belong to or are controlled by the Company, other
than the right to use, sell, or dispose of the products.
2/2