STANDARD DIODES
Features
600 A
High current capability
3000 VRMS isolating voltage with non-toxic substrate
High surge capability
High voltage ratings up to 2000V
Industrial standard package
UL E78996 approved
Typical Applications
Rectifying bridge for large motor drives
Rectifying bridge for large UPS
Major Ratings and Characteristics
Parameters
I F(AV)
@ TC
I F(RMS)
IRKD600..
Units
600
A
100
°C
942
A
@ TC
100
°C
I FSM
@ 50Hz
19.0
KA
@ 60Hz
20.1
KA
I 2t
@ 50Hz
1805
KA 2s
@ 60Hz
1683
KA 2s
18050
KA2√s
I 2√t
VRRM
range
800 to 2000
V
T STG
range
- 40 to 150
°C
TJ
range
- 40 to 150
°C
www.irf.com
1
IRKD600.. Series
Bulletin I27402 rev. A 09/97
ELECTRICAL SPECIFICATIONS
Voltage Ratings
Voltage
V RRM , maximum repetitive
VRSM , maximum non-
I RRM max.
Code
peak reverse voltage
V
repetitive peak rev. voltage
V
@ TJ max.
08
800
900
12
1200
1300
16
1600
1700
20
2000
2100
Type number
IRKD600..
mA
50
Forward Conduction
Parameter
IF(AV)
IRKD600..
Units Conditions
Maximum average forward current
600
A
@ Case temperature
100
°C
180° conduction, half sine wave
IF(RMS) Maximum RMS forward current
942
A
IFSM
Maximum peak, one-cycle forward,
19.0
KA
non-repetitive surge current
20.1
t = 8.3ms
reapplied
16.2
t = 10ms
100% VRRM
t = 8.3ms
reapplied
Sinusoidal half wave,
Initial TJ = TJ max.
17.2
2
It
2
Maximum I t for fusing
1805
2
KA s
Maximum I2 √t for fusing
No voltage
t = 10ms
No voltage
t = 8.3ms
reapplied
1319
t = 10ms
100% VRRM
1230
t = 8.3ms
reapplied
1683
I2 √t
180° conduction, half sine wave @ TC = 100°C
t = 10ms
18050
VF(TO)1 Low level value of threshold voltage
0.70
VF(TO)2 High level value of threshold voltage
0.77
r f1
Low level value of forward slope resistance
0.28
r f2
High level value of forward slope resistance
0.25
VFM
Maximum forward voltage drop
1.24
KA 2√s t = 0.1 to 10ms, no voltage reapplied
V
(16.7% x π x I F(AV) < I < π x IF(AV)), T J = TJ max.
(I > π x I F(AV)), TJ = TJ max.
mΩ
(16.7% x π x I F(AV) < I < π x IF(AV)), T J = TJ max.
(I > π x I F(AV)), TJ = TJ max.
V
Ipk = 1800A, TJ = 25°C, tp = 10ms sine pulse
Blocking
Parameter
VINS
IRRM
RMS isolation voltage
Maximum peak reverse and off-state
IRKD600..
Units Conditions
3000
V
50
mA
t=1s
TJ = TJ max., rated VRRM applied
leakage current
2
www.irf.com
IRKD600.. Series
Bulletin I27402 rev. A 09/97
Thermal and Mechanical Specifications
Parameter
IRKD600..
TJ
Max. junction operating temperature range
- 40 to 150
Tstg
Max. storage temperature range
- 40 to 150
RthJC
Max. thermal resistance, junction to
Units Conditions
°C
0.065
K/W
0.02
K/W
6-8
Nm
Per junction, DC operation
case
RthC-hs Max. thermal resistance, case to
heatsink
T
Mounting torque ± 10%SMAP to heatsink
busbar to SMAP
wt
12 - 15
Approximate weight
1500
Case style
A mounting compound is recommended and the
torque should be rechecked after a period of 3 hours
to allow for the spread of the compound
g
SUPER MAGN-A-pak
See outline table
∆RthJC Conduction
(The following table shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC)
Conduction angle
Sinusoidal conduction Rectangular conduction
180°
0.009
120°
0.011
0.011
90°
0.014
0.015
60°
0.021
0.022
30°
0.037
0.038
Units
Conditions
K/W
TJ = TJ max.
0.006
Ordering Information Table
1
Device Code
1
-
IRK
D
600
1
2
3
-
~
20
4
Module type
+
2
2
-
Circuit configuration D = 2 diodes in series
3
-
Current rating
4
-
Voltage code: Code x 100 = VRRM (See Voltage Ratings Table)
3
www.irf.com
3
IRKD600.. Series
Bulletin I27402 rev. A 09/97
Outline Table
4
150
IRKD600.. Series
R thJC (DC) = 0.065 K/W
140
130
Conduction Angle
120
110
100
30°
60°
90°
120°
90
180°
80
0
100
200
300
400
500
600
700
Maximum Allowable Case Temperature (°C)
Maximum Allowable Case Temperature (°C)
All dimensions in millimeters (inches)
150
IRKD600.. Series
R thJC(DC) = 0.065 K/W
140
130
120
Conduction Period
110
60°
100
30°
90°
90
120°
180°
DC
80
0
200
400
600
800
1000
Average Forward Current (A)
Average Forward Current (A)
Fig. 1 - Current Ratings Characteristics
Fig. 2 - Current Ratings Characteristics
www.irf.com
IRKD600.. Series
700
180°
120°
90°
60°
30°
600
500
RMS Limit
400
300
Conduction Angle
200
IRKD600.. Series
Per Junction
TJ = 150°C
100
0
0
100
200
300
400
500
1000
DC
180°
120°
90°
60°
30°
900
800
700
600
500
400
RMS Limit
Conduction Period
300
IRKD600.. Series
Per Junction
T J= 150°C
200
100
0
0
600
200
400
600
800
1000
Average Forward Current (A)
Average Forward Current (A)
Fig. 3 - Forward Power Loss Characteristics
Fig. 4 - Forward Power Loss Characteristics
18000
Peak Half Sine Wave Forward Current (A)
Peak Half Sine Wave Forward Current (A)
Maximum Average Forward Power Loss (W)
Maximum Average Forward Power Loss (W)
Bulletin I27402 rev. A 09/97
At Any Rated Load Condition And With
Rated V RRM Applied Following Surge.
16000
Initial TJ = 150°C
@ 60 Hz 0.0083 s
14000
@ 50 Hz 0.0100 s
12000
10000
8000
IRKD600.. Series
Per Junction
6000
4000
1
10
20000
Maximum Non Repetitive Surge Current
Versus Pulse Train Duration.
Initial T J = 150°C
No Voltage Reapplied
Rated VRRM Reapplied
18000
16000
14000
12000
10000
8000
IRKD600.. Series
Per Junction
6000
4000
0.01
100
0.1
Number Of Equal Amplitude Half Cycle Curre nt Pulses (N)
Pulse Train Duration (s)
Fig. 5 - Maximum Non-Repetitive Surge Current
Fig. 6 - Maximum Non-Repetitive Surge Current
1000
50
75
02
0.
=
2
K/
W
6K
/W
W
K/
-D
elt
a
0.2
5K
/W
0.3
5K
/W
0.5 K
/W
R
IRKD600.. Series
Per Junction
TJ = 150°C
200
SA
R th
400
W
600
K/
W
W
K/
0 .1
K/
0.
1
04
0.
08
800
180°
(Sine)
0.
DC
06
0.
Maximum Total Forward Power Loss (W)
1
0
0
200
400
600
800
Total RMS Output Current (A)
0
1000
25
100
125
150
Maximum Allowable Ambient Temperature (°C)
Fig. 7 - Forward Power Loss Characteristics
www.irf.com
5
IRKD600.. Series
Bulletin I27402 rev. A 09/97
=
01
0.
04
W
K/
ta
el
-D
R
0. 0
8
K/
W
0.12
1000
SA
1500
R th
2000
K
/W
K/
W
0.
05
K/
W
0.
W
K/
0.
03
180°
(Sine)
180°
(Rect)
2500
02
0.
Maximum Total Power Loss (W)
3000
K/W
2 x IRKD600.. Series 0.2 K
/W
Single Phase Bridge
Conn ected
T J = 150°C
500
0
0
200
400
600
800
1000
0
1200
25
50
75
100
125
150
Maximum Allowable Ambient Temperature (°C)
Total Output Current (A)
Fig. 8 - Forward Power Loss Characteristics
Rt
4000
A
hS
3000
02
K/
W
D
e
lta
2500
K/
W
-
0 .0
3
/W
K
120°
(Rect)
01
0.
0.
3500
=
R
Maximum Total Power Loss (W)
4500
0.0
5K
2000
1500
3 x IRKD600.. Series
Three Phase Bridge
Connected
T J = 150°C
1000
500
/W
0 .0
8 K/
W
0.12 K
/W
0.2 K /W
0
0
300
600
900
1200
1500
Total Output Current (A)
0
1800
25
50
75
100
125
150
Maximum Allowable Ambient Temperature (°C)
Fig. 9 - Forward Power Loss Characteristics
Transient Thermal Impedance Z thJ C (K/W)
Instantaneous Forward Current (A)
10000
1000
T J= 25°C
T J= 150°C
IRKD600.. Series
Per Junction
100
0.5
1
1.5
2
2.5
3
3.5
Instantaneous Forward Voltage (V)
Fig. 10 - Forward Voltage Drop Characteristics
6
0.1
IRKD600.. Series
Per Junction
0.01
Steady State Value:
R thJC = 0.065 K/W
(DC Operation)
0.001
0.001
0.01
0.1
1
10
100
Square Wave Pulse Duration (s)
Fig. 11 - Thermal Impedance ZthJC Characteristic
www.irf.com