ETC TSB41BA3-EP

TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
D Controlled Baseline
D
D
D
D
D
D
D
D
D
D
D
– One Assembly/Test Site, One Fabrication
Site
Extended Temperature Performance of
–40°C to 110°C
Enhanced Diminishing Manufacturing
Sources (DMS) Support
Enhanced Product-Change Notification
Qualification Pedigree†
Fully Supports Provisions of IEEE
1394b-2002 at S100, S100B, S200, S200B,
S400, and S400B Signaling Rates (B
Signifies 1394b Signaling)
Fully Supports Provisions of IEEE
1394a-2000 and 1394-1995 Standards for
High Performance Serial Bus
Fully Interoperable With Firewire,
SB1394, DishWire, and i.LINK
Implementation of IEEE Std 1394
Provides Three Fully Backward
Compatible, (1394a-2000 Fully Compliant)
Bilingual 1394b Cable Ports at
400 Megabits per Second (Mbits/s)
Same Three Fully Backward Compatible
Ports Are 1394a-2000 Fully Compliant
Cable Ports at 100/200/400 Mbits/s
Full 1394a-2000 Support Includes:
– Connection Debounce
– Arbitrated Short Reset
– Multispeed Concatenation
– Arbitration Acceleration
– Fly-By Concatenation
– Port Disable/Suspend/Resume
– Extended Resume Signaling for
Compatibility With Legacy DV Devices
Power-Down Features to Conserve Energy
in Battery Powered Applications
† Component qualification in accordance with JEDEC and industry
standards to ensure reliable operation over an extended
temperature range. This includes, but is not limited to, Highly
Accelerated Stress Test (HAST) or biased 85/85, temperature
cycle, autoclave or unbiased HAST, electromigration, bond
intermetallic life, and mold compound life. Such qualification
testing should not be viewed as justifying use of this component
beyond specified performance and environmental limits.
D Low-Power Sleep Mode
D Automotive Sleep Mode Support
D Fully Compliant With Open Host Controller
D
D
D
D
D
D
D
D
D
D
D
D
D
Interface (HCI) Requirements
Cable Power Presence Monitoring
Cable Ports Monitor Line Conditions for
Active Connection to Remote Node
Register Bits Give Software Control of
Contender Bit, Power Class Bits, Link
Active Control Bit, and 1394a-2000
Features
Data Interface to Link-Layer Controller Pin
Selectable From 1394a-2000 Mode (2/4/8
Parallel Bits at 49.152 MHz) or 1394b Mode
(8 Parallel Bits at 98.304 MHz)
Interface to Link-Layer Controller Supports
Low Cost TI Bus-Holder Isolation
Interoperable With Link-Layer Controllers
Using 3.3-V Supplies
Interoperable With Other 1394 Physical
Layers (PHYs) Using 1.8-V, 3.3-V, and 5-V
Supplies
Low Cost 49.152-MHz Crystal Provides
Transmit and Receive Data at
100/200/400 Mbits/s, and Link-Layer
Controller Clock at 49.152 MHz and
98.304 MHz
Separate Bias (TPBIAS) for Each Port
Low Cost, High Performance 80-Pin TQFP
(PFP) Thermally Enhanced Package
Software Device Reset (SWR)
Fail-Safe Circuitry Senses Sudden Loss of
Power to the Device and Disables the Ports
to Ensure That the TSB41BA3 Does Not
Load the TPBIAS of Any Connected Device
and Blocks Any Leakage From the Port
Back to Power Plane
The TSB41BA3 Has a 1394a-2000
Compliant Common-Mode Noise Filter on
the Incoming Bias Detect Circuit to Filter
Out Cross-Talk Noise
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Implements technology covered by one or more patents of Apple Computer, Incorporated and SGS Thompson, Limited.
i.LINK is a trademark of Sony Corporation.
FireWire is a trademark of Apple Computer Incorporated.
Copyright  2003, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
D Cable/Transceiver Hardware Speed and
description
The TSB41BA3 provides the digital and analog
transceiver functions needed to implement a
three-port node in a cable-based IEEE 1394
network. Each cable port incorporates two
differential line transceivers. The transceivers
include circuitry to monitor the line conditions as
needed for determining connection status, for
initialization and arbitration, and for packet
reception and transmission. The TSB41BA3 is
designed to interface with a link-layer controller
(LLC), such as the TSB82AA2, TSB12LV21,
TSB12LV26,
TSB12LV32,
TSB42AA4,
TSB42AB4, TSB12LV01B, or TSB12LV01C. It
may also be connected cable port to cable port to
an integrated 1394 Link + PHY layer such as the
TSB43AB2.
Port Mode Are Selectable by Pin States
– Supports Connection to CAT5 Cable
Transceiver by Allowing Ports to be
Forced to Beta-Only 100 Mbits/s only
– Supports Connection to S200 Plastic
Optical Fiber Transceivers by Allowing
Ports to be Forced to1394b Beta-Only
200 Mbits/s and S100 Mbits/s Only
– Supports Use of 1394a Connections by
Allowing Ports 1 and 2 to Be Forced to
1394a-Only Mode
– Optical Signal Detect Input for All Ports
in Beta Mode Enables Connection to
Optical Transceivers
The TSB41BA3 is powered by a single 3.3-V supply. The core voltage supply is supplied by an internal voltage
regulator to the PLLVDD-1.8 and DVDD-1.8 terminals. To protect the phase-locked loop (PLL) from noise, the
PLLVDD-1.8 terminals must be separately decoupled from the DVDD-1.8 terminals. The PLLVDD-1.8 terminals
are decoupled with 1-µF and smaller decoupling capacitors, and the DVDD-1.8 terminals are separately
decoupled with a 1-µF and smaller decoupling capacitors. The separation between DVDD-1.8 and PLLVDD-1.8
must be implemented by separate power supply rails or planes.
The TSB41BA3 may be powered by dual supplies, a 3.3-V supply for I/O and a core voltage supply. The core
voltage supply is supplied to the PLLVDD-1.8 and DVDD-1.8 terminals to the requirements in the recommended
operating conditions section of this data sheet. The PLLVDD-1.8 terminals must be separated from the
DVDD-1.8 terminals, the PLLVDD-1.8 terminals are decoupled with 1-µF and smaller decoupling capacitors,
and the DVDD-1.8 terminals separately decoupled with 1-µF and smaller decoupling capacitors. The separation
between DVDD-1.8 and PLLVDD-1.8 may be implemented by separate power supply rails, or by a single power
supply rail, where the DVDD-1.8 and PLLVDD-1.8 are separated by a filter network to keep noise from the
PLLVDD-1.8 supply.
The TSB41BA3 requires an external 49.152-MHz crystal to generate a reference clock. The external clock
drives an internal phase-locked loop (PLL), which generates the required reference signal. This reference signal
provides the clock signals that control transmission of the outbound encoded information. A 49.152-MHz clock
signal is supplied by the PHY to the associated LLC for synchronization of the two devices and is used for
resynchronization of the received data when operating the PHY-link interface in compliance with the IEEE
1394a-2000 standard. A 98.304-MHz clock signal is supplied by the PHY to the associated LLC for
synchronization of the two devices when operating the PHY-link interface in compliance with the IEEE
1394b-2002 standard. The power down (PD) function, when enabled by asserting the PD terminal high, stops
operation of the PLL.
ORDERING INFORMATION
TA
PACKAGE†
ORDERABLE
PART NUMBER
TOP-SIDE
MARKING
–40°C to 110°C
PQFP – PFP
Tray
TSB41BA3TPFPEP
TSB41BA3TEP
† Package drawings, standard packing quantities, thermal data, symbolization, and PCB design
guidelines are available at www.ti.com/sc/package.
2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
description (continued)
Data bits to be transmitted through the cable ports are received from the LLC on 2, 4, or 8 parallel paths
(depending on the requested transmission speed and PHY-link interface mode of operation). They are latched
internally, combined serially, encoded, and transmitted at 98.304, 122.78, 196.608, 245.76, 393.216, or
491.52 Mbits/s (referred to as S100, S100B, S200, S200B, S400, or S400B speed, respectively) as the
outbound information stream.
The PHY-link interface can follow either the IEEE 1394a-2000 protocol or the IEEE 1394b-2002 protocol. When
using a 1394a-2000 LLC such as the TSB12LV26, the BMODE terminal must be deasserted. The PHY-link
interface then operates in accordance with the legacy 1394a-2000 standard. When using a 1394b LLC such
as the TSB82AA2, the BMODE terminal must be asserted. The PHY-link interface then conforms to the
1394b-2002 standard.
The cable interface can follow either the IEEE 1394a-2000 protocol or the 1394b protocol on all ports. The mode
of operation is determined by the interface capabilities of the ports being connected. When any of the three ports
is connected to a 1394a-2000 compliant device, the cable interface on that port operates in the 1394a-2000
data-strobe mode at a compatible S100, S200, or S400 speed. When a bilingual port is connected to a 1394b
compliant node, the cable interface on that port operates per the 1394b-2002 standard at S100B, S200B, or
S400B speed. The TSB41BA3 automatically determines the correct cable interface connection method for the
bilingual ports.
NOTE:
The BMODE terminal does not select the cable interface mode of operation. The BMODE terminal
selects the PHY-link interface mode of operation and affects the arbitration modes on the cable.
When the BMODE terminal is deasserted, the PHY-link interface is placed in 1394a-2000 mode and
BOSS arbitration is disabled. When the BMODE terminal is asserted, the PHY-link interface is
placed in 1394b-2002 mode and BOSS arbitration is enabled.
During packet reception the serial data bits are split into two-, four-, or eight-bit parallel streams (depending upon
the indicated receive speed and the PHY-link interface mode of operation), resynchronized to the local system
clock and sent to the associated LLC. The received data is also transmitted (repeated) on the other connected
and active cable ports.
Both the twisted pair A (TPA) and the twisted pair B (TPB) cable interfaces incorporate differential comparators
to monitor the line states during initialization and arbitration when connected to a 1394a-2000 compliant device.
The outputs of these comparators are used by the internal logic to determine the arbitration status. The TPA
channel monitors the incoming cable common-mode voltage. The value of this common-mode voltage is used
during 1394a-mode arbitration and sets the speed of the next packet transmission. In addition, the TPB channel
monitors the incoming cable common-mode voltage on the TPB pair for the presence of the remotely supplied
twisted pair bias (TPBIAS) voltage.
When connected to a 1394a-2000 compliant node, the TSB41BA3 provides a 1.86-V nominal bias voltage at
the TPBIAS terminal for port termination. The PHY contains three independent TPBIAS circuits (one for each
port). This bias voltage, when seen through a cable by a remote receiver, indicates the presence of an active
connection. This bias voltage source must be stabilized by an external filter capacitor of 1 µF.
The line drivers in the TSB41BA3, are designed to work with external 112-Ω termination resistor networks in
order to match the 110-Ω cable impedance. One termination network is required at each end of a twisted-pair
cable. Each network is composed of a pair of series-connected ~56-Ω resistors. The midpoint of the pair of
resistors that are connected to the TPA terminals is connected to its corresponding TPBIAS voltage terminal.
The midpoint of the pair of resistors that are directly connected to the TPB terminals is coupled to ground through
a parallel RC network with recommended values of 5 kΩ and 270 pF. The values of the external line-termination
resistors are designed to meet the standard specifications when connected in parallel with the internal receiver
circuits. A precision external resistor connected between the R0 and R1 terminals sets the driver output current,
along with other internal operating currents.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
description (continued)
When the power supply of the TSB41BA3 is off while the twisted-pair cables are connected, the TSB41BA3
transmitter and receiver circuitry present a high-impedance signal to the cable that does not load the device at
the other end of the cable.
When the TSB41BA3 is used without one or more of the ports brought out to a connector, the twisted-pair
terminals of the unused ports must be terminated for reliable operation. For each unused port, the preferred
method is for the port to be forced to the 1394a-only mode (data-strobe-only mode, DS), then the TPB+ and
TPB– terminals can be tied together and then pulled to ground; or the TPB+ and TPB– terminals can be
connected to the suggested normal termination network. The TPA+ and TPA– terminals of an unused port can
be left unconnected. The TPBIAS#_SD# terminal may be left unconnected.
If the port is left in bilingual (Bi) mode, then the TPB+ and TPB– terminals may be left unconnected or the TPB+
and TPB– terminals can be connected to the suggested normal termination network. The TPA+ and TPA–
terminals of an unused port can be left unconnected. The TPBIAS#_SD# terminal can be left unconnected.
If the port is left in a forced 1394b beta only (B1, B2, or B4) mode, then the TPB+ and TPB– terminals may be
left unconnected or the TPB+ and TPB– terminals can be connected to the suggested normal termination
network. The TPA+ and TPA– terminals of an unused port can be left unconnected. The TPBIAS#_SD# terminal
must be pulled to ground through a 1.2-kΩ or less resistor.
To operate a port as a 1394b bilingual port, the speed/mode selections terminals (S5_LKON_DS2, S4_DS1,
S3_DS0, S2_PC0, S1_PC1, and S0_PC2) need to be pulled to VCC or ground through a 1-kΩ resistor. The port
must be operated in the 1394b bilingual mode whenever a 1394b bilingual or a 1394b beta-only connector is
connected to the port. To operate the port as a 1394a-only port, the speed/mode selection terminals must be
configured correctly to force 1394a-2000-only operation on that port. The only time the port must be forced to
the data-strobe-only mode is if the port is connected to a 1394a connector (either 6-pin, which is recommended,
or 4-pin). This mode is provided to ensure that 1394b signaling is never sent across a 1394a cable.
NOTE:A bilingual port can only connect to a 1394b-only port that operates at S400b. It can not
establish a connection to a S200b or S100b port. A port that has been forced to S400b (B4) can
connect to a 1394b-only port at S400b (B4) or S200b (B2) or S100b (B1). A port that has been forced
to S200b can connect to a 1394b-only port at S200b or S100b. A port that has been forced to S100b
can only connect to a 1394b-only port at S100b.
The TESTM, SE, and SM terminals are used to set up various manufacturing test conditions. For normal
operation, the TESTM terminal must be connected to VDD through a 1-kΩ resistor. The SE and SM terminals
must be tied to ground through a 1-kΩ resistor.
Three package terminals are used as inputs to set the default value for three configuration status bits in the
self-ID packet. They may be pulled high through a 1-kΩ resistor or hardwired low as a function of the equipment
design. In some speed/mode selections the S2_PC0, S1_PC1, and S0_PC2 terminals indicate the default
power class status for the node (the need for power from the cable or the ability to supply power to the cable),
please see Table 1. The contender bit in the PHY register set indicates that the node is a contender either for
the isochronous resource manager (IRM) or for the bus manager (BM). On the TSB41BA3, this bit may only
be set by a write to the PHY register set. If a node desires to be a contender for IRM or BM, then the node
software must set this bit in the PHY register set.
The LPS (link power status) terminal works with the S5_LKON_DS2 terminal to manage the power usage in
the node. The LPS signal from the LLC is used in conjunction with the LCtrl bit (see Table 2 and Table 3 in the
APPLICATION INFORMATION section) to indicate the active/power status of the LLC. The LPS signal also
resets, disables, and initializes the PHY-LLC interface (the state of the PHY-LCC interface is controlled solely
by the LPS input regardless of the state of the LCtrl bit).
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
description (continued)
NOTE:The TSB41BA3 does not have a cable-not-active (CNA) pin. To achieve a similar function,
the individual PHY ports may be set-up to issue interrupts whenever the port changes state. If the
LPS pin is low, then this generates a link-on (LKON) output clock. Please see register bits PIE, PEI,
and WDIE along with the individual interrupt bits.
The LPS input is considered inactive if it remains low for more than the LPS_RESET time (see the LPS terminal
definition) and is considered active otherwise. When the TSB41BA3 detects that the LPS input is inactive, the
PHY-LLC interface is placed into a low-power reset state in which the CTL and D outputs are held in the logic
0 state and the LREQ input is ignored; however, the PCLK output remains active. If the LPS input remains low
for more than the LPS_DISABLE time (see the LPS terminal definition), then the PHY-LLC interface is put into
a low-power disabled state in which the PCLK output is also held inactive. The TSB41BA3 continues the
necessary repeater functions required for normal network operation regardless of the state of the PHY-LLC
interface. When the interface is in the reset or disabled state and the LPS input is again observed active, the
PHY initializes the interface and returns to normal operation. The PHY-LLC interface is also held in the disabled
state during hardware reset. When the LPS terminal is returned to an active state after being sensed as having
entered the LPS_DISABLE time, the TSB41BA3 issues a bus reset. This broadcasts the node self-ID packet,
which contains the updated L bit state (the PHY LLC now being accessible).
The PHY uses the S5_LKON_DS2 terminal to notify the LLC to power up and become active. When activated,
the output S5_LKON_DS2 signal is a square wave. The PHY activates the S5_LKON_DS2 output when the
LLC is inactive and a wake-up event occurs. The LLC is considered inactive when either the LPS input is
inactive, as described above, or the LCtrl bit is cleared to 0. A wake-up event occurs when a link-on PHY packet
addressed to this node is received, or conditionally when a PHY interrupt occurs. The PHY deasserts the
S5_LKON_DS2 output when the LLC becomes active (both LPS sensed as active and the LCtrl bit set to 1).
The PHY also deasserts the S5_LKON_DS2 output when a bus reset occurs, unless a PHY interrupt condition
exists which would otherwise cause S5_LKON_DS2 to be active. If the PHY is power cycled and the power class
is 0 through 4, then the PHY asserts S5_LKON_DS2 for approximately 167 µs or until both the LPS is active
and the LCtrl bit is 1.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
pin assignments
TPA0+
TPA0–
AVDD
AGND
TPB0+
TPB0–
TPBIAS1_SD1
TPA1+
TPA1–
AVDD
AGND
TPB1+
TPB1–
TPBIAS0_SD0
TPA2+
TPA2–
AVDD
TPB2+
TPB2–
TPBIAS2_SD2
PFP PACKAGE
(TOP VIEW)
60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41
61
40
62
39
63
38
64
37
65
36
66
35
67
34
68
33
32
69
70
TSB41BA3
30
72
29
73
28
74
27
75
26
76
25
77
24
78
23
79
22
80
4 5
PINT
S5_LKON_DS2
LREQ
DGND
PCLK
1 2 3
6
31
71
6
21
7 8 9 10 11 12 13 14 15 16 17 18 19 20
DVDD–3.3
LCLK_PMC
DVDD–1.8
CTL0
CTL1
D0
D1
D2
DGND
D3
D4
D5
DVDD–3.3
D6
D7
AGND
AGND
AVDD
DGND
DVDD–1.8
S2_PC0
S1_PC1
S0_PC2
DVDD–3.3
DVDD–3.3
DVDD–1.8
DGND
VREG_PD
BMODE
RESETz
DGND
PD
TESTM
SLPEN
LPS
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
AGND
AVDD
DGND
DVDD–1.8
SM
SE
CPS
S3_DS0
S4_DS1
PLLVDD–3.3
PLLVDD–1.8
PLLVDD–1.8
PLLGND
XI
XO
PLLGND
AVDD
R0
R1
AGND
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
functional block diagram
R0
CPS
LPS
SLPEN
PINT
Bias Voltage
and
Current
Generator
Received Data
Decoder/Retimer
Link
Interface
I/O
TPA0+
TPA0–
D1
D2
D3
D4
Cable Port 0
D5
D6
D7
TPB0+
TPB0–
Arbitration
and Control
State Machine
Logic
RESETz
S5_LKON_DS2
BMODE
TPA1+
TPA1–
PD
S2_PC0
S1_PC1
S0_PC2
SE
SM
S3_DS0
S4_DS1
TESTM
Cable Port 1
TPB1+
TPB1–
TPA2+
TPA2–
Cable Port 2
TPB2+
TPB2–
Crystal Oscillator,
PLL System,
and Transmit
Clock Generator
VREG_PD
TPBIAS1_SD1
TPBIAS2_SD2
PCLK
LCLK_PMC
LREQ
CTL0
CTL1
D0
R1
TPBIAS0_SD0
Voltage
Regulator
XO
XI
Transmit
Data
Encoder
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
7
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
Terminal Functions
TERMINAL
I/O
DESCRIPTION
21, 40, 43,
50, 61, 62
–
Analog circuit ground terminals. These terminals must be tied together to the low-impedance circuit
board ground plane.
Supply
24, 39, 44,
51, 57, 63
–
Analog circuit power terminals. A combination of high-frequency decoupling capacitors near each
terminal are suggested, such as paralleled 0.1 µF and 0.001 µF. Lower frequency 10-µF filtering
capacitors are also recommended. These supply terminals are separated from the PLLVDD-1.8,
PLLVDD-3.3, DVDD-1.8, and DVDD-3.3 terminals internal to the device to provide noise isolation.
The PLLVDD-3.3, AVDD, and DVDD-3.3 terminals must be tied together with a low dc impedance
connection on the circuit board.
BMODE
CMOS
74
I
Beta-mode input. This terminal determines the PHY-link interface connection protocol. When logic
high (asserted), the PHY-link interface complies with the 1394b-2002 B PHY-link interface. When
logic low (deasserted), the PHY-link interface complies with the legacy 1394a-2000 standard.
When using an LLC such as the 1394b-2002 TSB82AA2, this terminal must be pulled high. When
using an LLC such as the 1394a-2000 TSB12LV26, this terminal must be tied low.
NOTE: The PHY-link interface cannot be changed between the different protocols during operation.
CPS
CMOS
34
I
Cable power status input. This terminal is normally connected to cable power through a 400-kΩ
resistor. This circuit drives an internal comparator that detects the presence of cable power. This
transition from cable power sensed to cable power not sensed may be used to generate an interrupt
to the LLC.
CTL0
CTL1
CMOS
9
10
I/O
Control I/Os. These bidirectional signals control communication between the TSB41BA3 and the
LLC. Bus holders are built into these terminals.
D0–D7
CMOS
11, 12, 13,
15, 16, 17,
19, 20
I/O
Data I/Os. These are bidirectional data signals between the TSB82BA3 and the LLC. Bus holders
are built into these terminals.
If power management control (PMC) is selected using LCLK_PMC, then some of these terminals
may be used for PMC. See the LCLK_PMC terminal description for more information.
DGND
Supply
4, 14, 38,
64, 72, 76
DVDD-1.8
Supply
8, 37, 65,
71
–
Digital 1.8-V circuit power terminals. A combination of high-frequency decoupling capacitors near
each terminal are suggested, such as paralleled 0.1 µF and 0.001 µF. An additional 1-µF capacitor
is required for voltage regulation. These supply terminals are separated from the DVDD-3.3,
PLLVDD-1.8, PLLVDD-3.3, and AVDD terminals internal to the device to provide noise isolation.
DVDD-3.3
Supply
6, 18, 69,
70
–
Digital 3.3-V circuit power terminals. A combination of high-frequency decoupling capacitors near
each terminal are suggested, such as paralleled 0.1 µF and 0.001 µF. Lower frequency 10-µF
filtering capacitors are also recommended. The DVDD-3.3 terminals must be tied together at a
low-impedance point on the circuit board. These supply terminals are separated from the
PLLVDD-1.8, PLLVDD-3.3, DVDD-1.8, and AVDD terminals internal to the device to provide noise
isolation. The PLLVDD-3.3, AVDD, and DVDD-3.3 terminals must be tied together with a low dc
impedance connection on the circuit board.
NAME
TYPE
NO.
AGND
Supply
AVDD
8
Digital circuit ground terminals. These terminals must be tied together to the low-impedance circuit
board ground plane.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
Terminal Functions (Continued)
TERMINAL
I/O
DESCRIPTION
7
I
Link clock. Link-provided 98.304-MHz clock signal to synchronize data transfers from link to the PHY.
On hardware reset this terminal is sampled to determine the power management control (PMC) mode.
LPS
BMODE
Mode
LCLK_PMC
H
L
H
No LLC (PMC mode)
n/c†
lps
L
Legacy LLC
LCLK_PMC‡
lps
H
Beta LLC
† internal pulldown on LCLK_PMC
‡ LCLK_PMC from LLC normally low during reset
In PMC mode, since no LLC is attached the data lines (D7–D0) are available to indicate power
states. In PMC mode the following signals are output:
– D0—port 0 cable-power disable (see Note 1)
– D1—port 1 cable-power disable (port in sleep or disabled)
– D2—port 2 cable-power disable (port in sleep or disabled)
– D6—All ports cable-power disable (all ports in sleep/disable) logical AND of bits 0–2
– D3–D5 and D7 are reserved for future use.
Note 1: The cable-power disable is asserted when the port is either:
– Hard-disabled (both the disabled and hard disabled bits are set)
– Sleep-disabled (both the disabled and sleep_enable bits are set)
– Disconnected
– Asleep
– Connected in DS mode, but nonactive (that is, suspended or disabled)
Otherwise, the cable-powered disable output is deasserted (that is, cable power enabled) when
the port is dc-connected or active. A bus holder is built into this terminal.
CMOS
80
I
Link power status input. This terminal monitors the active/power status of the link-layer controller
(LLC) and controls the state of the PHY-LLC interface. This terminal must be connected to either the
VDD supplying the LLC through an approximately 1-kΩ resistor or to a pulsed output which is active
when the LLC is powered. A pulsed signal must be used when an isolation barrier exists between the
LLC and PHY (see Figure 8).
The LPS input is considered inactive if it is sampled low by the PHY for more than a LPS_RESET time
(~2.6 µs), and is considered active otherwise (that is, asserted steady high or an oscillating signal with
a low time less than 2.6 µs). The LPS input must be high for at least 22 ns to be guaranteed to be
observed as high by the PHY.
When the TSB41BA3 detects that the LPS input is inactive, it places the PHY-LLC interface into a
low-power reset state. In the reset state, the CTL (CTL0 and CTL1) and D (D0 to D7) outputs are held
in the logic 0 state and the LREQ input is ignored; however, the PCLK output remains active. If the LPS
input remains low for more than a LPS_DISABLE time (~26 µs), then the PHY-LLC interface is put into
a low-power disabled state in which the PCLK output is also held inactive. The PHY-LLC interface is
placed into the disabled state upon hardware reset.
The LLC state that is communicated in the self-ID packet is considered active only if both the LPS input
is active and the LCtrl register bit is set to 1. The LLC state that is communicated in the self-ID packet is
considered inactive if either the LPS input is inactive or the LCtrl register bit is cleared to 0.
When the LPS terminal is returned to an active state after being sensed as having entered the
LPS_DISABLE time, the TSB41BA3 issues a bus reset. This broadcasts the node self-ID packet,
which contains the updated L bit state (the PHY LLC now being accessible).
LREQ
CMOS
3
I
LLC request input. The LLC uses this input to initiate a service request to the TSB41BA3. A bus holder
is built into this terminal.
PCLK
CMOS
5
O
PHY clock. Provides a 98.304-MHz clock signal, synchronized with data transfers, to the LLC when
the PHY-link interface is operating in the 1394b mode (BMODE asserted). PCLK output provides a
49.152-MHz clock signal, synchronized with data transfers, to the LLC when the PHY-link interface is
in legacy 1394a-2000 (BMODE input deasserted).
PD
CMOS
77
I
Power-down input. A high on this terminal turns off all internal circuitry. Asserting the PD input high
also activates an internal pulldown on the RESETz terminal to force a reset of the internal control logic.
PINT
CMOS
1
O
PHY Interrupt. The PHY uses this output to serially transfer status and interrupt information to the link
when PHY-link interface is in the 1394b mode. A bus holder is built into this terminal.
PLLGND
Supply
25,
28
–
PLL circuit ground terminals. These terminals must be tied together to the low-impedance circuit
board ground plane.
NAME
TYPE
NO.
LCLK_PMC
CMOS
LPS
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
9
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
Terminal Functions (Continued)
TERMINAL
I/O
DESCRIPTION
29,
30
–
PLL 1.8-V circuit power terminals. A combination of high-frequency decoupling capacitors near each
terminal are suggested, such as paralleled 0.1 µF and 0.001 µF. An additional 1-µF capacitor is
required for voltage regulation. The PLLVDD-1.8 terminals must be separate from the DVDD-1.8
terminals. These supply terminals are separated from the DVDD-1.8, DVDD-3.3, PLLVDD-3.3 and
AVDD-3.3 terminals internal to the device to provide noise isolation.
Supply
31
–
PLL 3.3-V circuit power terminal. A combination of high-frequency decoupling capacitors near the
terminal are suggested, such as paralleled 0.1 µF and 0.001 µF. Lower frequency 10-µF filtering
capacitors are also recommended. This supply terminal is separated from the DVDD-1.8, DVDD-3.3,
PLLVDD-1.8, and AVDD-3.3 terminals internal to the device to provide noise isolation. The DVDD-3.3
terminals must be tied together at a low-impedance point on the circuit board. The PLLVDD-3.3,
AVDD-3.3, and DVDD-3.3 terminals must be tied together with a low dc impedance connection.
RESETz
CMOS
75
I
Logic reset input. Asserting this terminal low resets the internal logic. An internal pullup resistor to VDD
is provided so only an external delay capacitor is required for proper power-up operation (see power-up
reset in the APPLICATIONS INFORMATION section). The RESETz terminal also incorporates an
internal pulldown which is activated when the PD input is asserted high. This input is otherwise a
standard logic input, and can also be driven by an open-drain type driver.
R0
R1
Bias
23
22
–
Current setting resistor terminals. These terminals are connected to a precision external resistance to
set the internal operating currents and cable driver output currents. A resistance of 6.34 kΩ ±1% is
required to meet the IEEE Std 1394-1995 output voltage limits.
SE
CMOS
35
I
Test control input. This input is used in the manufacturing test of the TSB41BA3. For normal use this
terminal must be pulled low either through a 1-kΩ resistor to GND or directly to GND.
SLPEN
CMOS
79
I
Automotive sleep mode enable input. This terminal is used to enable the automotive sleep mode.
When deasserted, normal 1394.b functionality is maintained.
SM
CMOS
36
I
Test control input. This input is used in the manufacturing test of the TSB41BA3. For normal use this
terminal must be pulled low either through a 1-kΩ resistor to GND or directly to GND.
S2_PC0
S1_PC1
S0_PC2
CMOS
66
67
68
I
Port sleep/mode selection terminals 2–0 and power class programming. On hardware reset, this
terminal when used with the other 5 selection pins allows the user to select the speed and mode of the
ports. See Table 1. Depending on the selection these inputs may set the default value of the power
class indicated during self-ID.
Programming is done by tying the terminals high through a 1-kΩ or smaller resistor or by tying directly to
ground through a 1-kΩ or smaller resistor. Bus holders are built into these terminals.
S3_DS0
CMOS
33
I
Port sleep/mode selection terminal 3. On hardware reset, this terminal when used with the other 5
selection pins allows the user to select the speed and mode of the ports. See Table 1. Programming is
done by tying the terminals high through a 1-kΩ or smaller resistor or by tying directly to ground through
a 1-kΩ or smaller resistor. A bus holder is built into this terminal.
S4_DS1
CMOS
32
I
Port sleep/mode selection terminal 4. On hardware reset, this terminal when used with the other 5
selection pins allows the user to select the speed and mode of the ports. See Table 1. Programming is
done by tying the terminals high through a 1-kΩ or smaller resistor or by tying directly to ground through
a 1-kΩ or smaller resistor. A bus holder is built into this terminal.
NAME
TYPE
NO.
PLLVDD-1.8
Supply
PLLVDD-3.3
10
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
Terminal Functions (Continued)
TERMINAL
I/O
DESCRIPTION
2
I/O
Port sleep/mode selection terminal 5 and link-on output. This terminal may be connected to the linkon input terminal of the LLC through a 1-kΩ resistor if the link-on input is available on the link layer.
On hardware reset, this terminal when used with the other 5 selection pins allows the user to select
the speed and mode of the ports. See Table 1. A bus holder is built into this terminal.
After hardware reset, this terminal is the link-on output, which notifies the LLC or other power-up
logic to power up and become active. The link-on output is a square wave signal with a period of
approximately 163 ns (8 PCLK cycles) when active. The link-on output is otherwise driven low, except during hardware reset when it is high impedance.
The link-on output is activated if the LLC is inactive (the LPS input inactive or the LCtrl bit cleared)
and when one:
a) The PHY receives a link-on PHY packet addressed to this node
b) The PEI (port-event interrupt) register bit is 1, or
c) Any of the CTOI (configuration-timeout interrupt), CPSI (cable-power-status interrupt), or
d) The PHY is power cycled and the power class is 0 through 4
Once activated, the link-on output is active until the LLC becomes active (both the LPS input active
and the LCtrl bit set). The PHY also deasserts the link-on output when a bus-reset occurs unless the
link-on output is otherwise active because one of the interrupt bits is set (that is, the link-on output is
active due solely to the reception of a link-on PHY packet).
In the case of power cycling the PHY, the LKON signal must stop after 167 µs if the above conditions
have not been met.
NOTE: If an interrupt condition exists which otherwise causes the link-on output to be activated if
the LLC were inactive, then the link-on output is activated when the LLC subsequently becomes
inactive.
CMOS
78
I
Test control input. This input is used in the manufacturing test of the TSB41BA3. For normal use this
terminal must be pulled high through a 1-kΩ resistor to VDD.
TPA0–
TPA0+
TPB0–
TPB0+
Cable
45,
46,
41,
42
I/O
Port 0 twisted-pair differential-signal terminals. Board traces from each pair of positive and
negative differential signal terminals must be kept matched and as short as possible to the
external load resistors and to the cable connector. Please request the S800 1394b layout
recommendations document from your TI representative.
TPA1–
TPA1+
TPB1–
TPB1+
Cable
52
53
48
49
I/O
Port 1 twisted-pair differential-signal terminals. Board traces from each pair of positive and
negative differential signal terminals must be kept matched and as short as possible to the
external load resistors and to the cable connector. Please request the S800 1394b layout
recommendations document from your TI representative.
TPA2–
TPA2+
TPB2–
TPB2+
Cable
58
59
55
56
I/O
Port 2 twisted-pair differential-signal terminals. Board traces from each pair of positive and negative
differential signal terminals must be kept matched and as short as possible to the external load
resistors and to the cable connector. Please request the S800 1394b layout recommendations
document from your TI representative.
TPBIAS0_SD0
TPBIAS1_SD1
TPBIAS2_SD2
Cable
In
47
54
60
I/O
Twisted-pair bias output and signal detect input. This provides the 1.86-V nominal bias voltage
needed for proper operation of the twisted-pair cable drivers and receivers, and for signaling to the
remote nodes that there is an active cable connection in 1394a-2000 mode. Each of these
terminals, except for an unused port, must be decoupled with a 1.0-µF capacitor to ground. For the
unused port, this terminal can be left unconnected.
When a port is configured as a beta mode port (B1, B2, B4) this terminal becomes an input and must
be high when a valid signal is present. For optical transceivers the signal detect of the transceiver
must be connected to this terminal. The input is an LVCMOS level input.
VREG_PD
CMOS
73
I
Voltage regulator powerdown input. When asserted logic high, this pin powers down the internal
3.3-V-to-1.8-V regulator. For single-supply (3.3-V only) operation, this pin must be tied to GND.
XI
XO
Crystal
27
26
I
O
Crystal oscillator inputs. These terminals connect to a 49.152-MHz parallel resonant fundamental
mode crystal. The optimum values for the external shunt capacitors are dependent on the
specifications of the crystal used (see crystal selection section in the document SLLS418A). XI is a
1.8-V CMOS input.
NAME
TYPE
NO.
S5_LKON_DS2
CMOS
TESTM
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
11
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
Table 1. Port Speed/Mode Selection
MODE
NO.
S5_LINK
ON_DS2
S4_
DS1
S3_
DS0
S2_
PC0
S1_
PC1
S0_
PC2
PORT 2
1
0
0
0
PC0
PC1
PC2
Bil †
T
2
0
0
1
PC0
PC1
PC2
DS ‡
3
0
1
0
PC0
PC1
PC2
DS
4
0
1
1
0
0
0
5
0
1
1
0
0
1
6
0
1
1
0
1
7
0
1
1
0
8
0
1
1
1
PORT 1
PORT 0
POWER CLASS
Bil
T
Bil
T
PC = (PC0, PC1, PC2)
1394b
T
Bil
T
Bil
T
PC = (PC0, PC1, PC2)
1394b
T
DS
T
Bil
T
PC = (PC0, PC1, PC2)
1394b
B1 §
S
B1
S
B1
S
PC = 000
1394b
B2 ¶
S
B2
S
B2
S
PC = 000
1394b
0
B4 #
S
B4
S
B4
S
PC = 000
1394b
1
1
B2
S
Bil
T
B4
S
PC = 100
1394b
0
0
B1
S
DS
T
DS
T
PC = 100
1394a
S100
9
0
1
1
1
0
1
DS
T
DS
T
B2
S
PC = 100
1394b
10
0
1
1
1
1
0
DS
T
DS
T
B4
S
PC = 100
1394b
11
0
1
1
1
1
1
B2
S
DS
T
B4
S
PC = 100
1394b
12
1
0
0
PC0
0
0
B1
S
Bil
T
B1
S
PC = PC0,0,0 (100 or 000)
1394b
13
1
0
0
PC0
0
1
B2
S
Bil
T
B2
S
PC = PC0,0,0 (100 or 000)
1394b
14
1
0
0
PC0
1
0
B4
S
Bil
T
B4
S
PC = PC0,0,0 (100 or 000)
1394b
15
1
0
0
PC0
1
1
B1
S
Bil
T
B2
S
PC = PC0,0,0 (100 or 000)
1394b
16
1
0
1
PC0
0
0
Bil
T
Bil
T
B1
S
PC = PC0,0,0 (100 or 000)
1394b
17
1
0
1
PC0
0
1
Bil
T
Bil
T
B2
S
PC = PC0,0,0 (100 or 000)
1394b
18
1
0
1
PC0
1
0
Bil
T
Bil
T
B4
S
PC = PC0,0,0 (100 or 000)
1394b
19
1
0
1
PC0
1
1
B1
S
Bil
T
B4
S
PC = PC0,0,0 (100 or 000)
1394b
20
1
1
0
PC0
0
0
DS
T
Bil
T
B1
S
PC = PC0,0,0 (100 or 000)
1394b
21
1
1
0
PC0
0
1
DS
T
Bil
T
B2
S
PC = PC0,0,0 (100 or 000)
1394b
22
1
1
0
PC0
1
0
DS
T
Bil
T
B4
S
PC = PC0,0,0 (100 or 000)
1394b
23
1
1
0
PC0
1
1
B1
S
DS
T
B2
S
PC = PC0,0,0 (100 or 000)
1394b
24
1
1
1
PC0
0
0
B1
S
DS
T
B1
S
PC = PC0,0,0 (100 or 000)
1394b
25
1
1
1
PC0
0
1
B2
S
DS
T
B2
S
PC = PC0,0,0 (100 or 000)
1394b
26
1
1
1
PC0
1
0
B4
S
DS
T
B4
S
PC = PC0,0,0 (100 or 000)
1394b
27
1
1
1
PC0
1
1
B1
S
DS
T
B4
S
PC = PC0,0,0 (100 or 000)
1394b
† Bil = 1394b-2002 Bilingual (S400b only Beta operating speed and data strobe: S400, S200, and S100 operating speeds)
‡ DS = 1394a-2000, data strobe-only, S400, S200, and S100 operating speeds
§ B1 = 1394b-2002 Beta-only, S100b operating speed
¶ B2 = 1394b-2002 Beta-only, S200b and S100b operating speeds
# B4 = 1394b-2002 Beta-only, S400b, S200b, and S100b operating speeds
S = TPBIAS#_SD# pin is in signal detect input mode
T = TPBIAS#_SD# pin is in TPBIAS output mode
12
SELF-ID
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
port mode/speed selection example connections
3.3 V
TSB41BA3
3.3 V
Signal Detect
S5_DS2
TPBIAS0_SD0
S4_DS1
Port 0
S3_DS0
TPBIAS1_SD1
S2_PC0
Port 1
S1_PC1
TPBIAS2_SD2
S0_PC2
Port 2
POF
S200
TPBIAS
PC0 (Don’t Care)
1394b
9-Pin
Bilingual
3.3 V
TPBIAS
1394a
6-Pin DS
Mode 21, Port/Speed Mode (1, 1, 0, PC0, 0, 1)
SD High
3.3 V
3.3 V
TSB41BA3
3.3 V
Signal
Detect
S5_DS2
TPBIAS0_SD0
S4_DS1
Port 0
S3_DS0
TPBIAS1_SD1
S2_PC0
Port 1
S1_PC1
TPBIAS2_SD2
S0_PC2
Port 2
TSB17BA1
Transformer
3.3 V
PC0 (Don’t Care)
RJ45
S100
TPBIAS
1394a
6-Pin DS
Signal Detect
POF
S100
Mode 24, Port/Speed Mode (1, 1, 1, PC0, 0, 0)
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
13
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Supply voltage range, VDD (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 4 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to VDD + 0.5 V
Output voltage range at any output, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to VDD + 0.5 V
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free air temperature, TA TSB41BA3T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to110°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values, except differential I/O bus voltages, are with respect to network ground.
PACKAGE
PFP§
PFP¶
TA ≤ 25°C
POWER RATING
5.05 W
DISSIPATION RATING TABLE
DERATING FACTOR‡
ABOVE TA = 25°C
TA = 70°C
POWER RATING
52.5 mW/°C
2.69 W
TA = 110°C
POWER RATING
587 mW
3.05 W
31.7 mW/°C
1.62 W
355 mW
PFP#
2.01 W
20.3 mW/°C
1.1 W
284 mW
‡ This is the inverse of the traditional junction-to-ambient thermal resistance (RθJA).
§ 2 oz. trace and copper pad with solder.
¶ 2 oz. trace and copper pad without solder.
# For more information, refer to TI application note PowerPAD  Thermally Enhanced Package, (SLMA002).
PowerPAD is a trademark of Texas Instruments.
14
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
recommended operating conditions
Source power node
3 VDD
Supply voltage
voltage, 3
3.3
Nonsource power node
Supply voltage, 1.8 VDD
LREQ, CTL0, CTL1, D0–D7, LCLK_PMC
High-level input voltage, VIH
MIN
TYP†
MAX
3.0
3.0‡
3.3
3.6
3.3
3.6
1.75
1.85
1.95
0.7×VDD
RESETz
0.6×VDD
–4
0.3×VDD
4
mA
–5.6
1.3
mA
124.13
°C
mV
CTL0, CTL1, D0–D7, S5_LKON_DS2, PINT, PCLK
Output current, IO
TPBIAS outputs
Maximum junction temperature, TJ
(see RθJA values listed in thermal
characteristics table)
RθJA = 19°C/W,
1394b Differential input voltage, VID
Cable inputs, during data reception
200
800
Cable inputs, during data reception
118
260
Cable inputs, during arbitration
168
265
2.515
2.015‡
TA = 110°C
TPB cable inputs, source power node
0.4706
Common mode input voltage,
voltage VIC
1394a Common-mode
TPB cable inputs, nonsource power node
Power-up reset time, tpu
RESETz input
0.4706
2§
Receive in
input
ut jitter
Receive in
input
ut skew
V
0.2×VDD
Output current, IOL/OH
TPA, TPB cable inputs, S100 operation
V
V
1.2
S5_LKON_DS2, S4_DS1, S3_DS0, S2_PC0,
S1_PC1, S0_PC2, SLPEN, PD, BMODE,
TPBIAS0_SD0, TPBIAS1_SD1, TPBIAS2_SD2
RESETz
1394a Differential input voltage
voltage, VID
V
2.6
S5_LKON_DS2, S4_DS1, S3_DS0, S2_PC0,
S1_PC1, S0_PC2, SLPEN, PD, BMODE,
TPBIAS0_SD0, TPBIAS1_SD1, TPBIAS2_SD2
LREQ, CTL0, CTL1, D0–D7, LCLK_PMC
Low-level input voltage, VIL
UNIT
mV
V
ms
±1.08
TPA, TPB cable inputs, S200 operation
±0.5
TPA, TPB cable inputs, S400 operation
±0.315
Between TPA and TPB cable inputs, S100 operation
±0.8
Between TPA and TPB cable inputs, S200 operation
±0.55
Between TPA and TPB cable inputs, S400 operation
±0.5
ns
ns
† All typical values are at VDD = 3.3 V and TA = 25°C.
‡ For a node that does not source power; see Section 4.2.2.2 in IEEE 1394a-2000.
§ Time after valid clock received at PHY XI input terminal.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
15
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
electrical characteristics over recommended ranges of operating conditions (unless otherwise noted)
driver
PARAMETER
TEST CONDITION
56 Ω,
VOD
VOD
1394a differential output voltage
See Figure 1
IDIFF
ISP200
Driver difference current, TPA+, TPA–, TPB+, TPB–
Common-mode speed signaling current, TPB+, TPB–
S200 speed signaling enabled
ISP400
VOFF
Common-mode speed signaling current, TPB+, TPB–
S400 speed signaling enabled
Off state differential voltage
Drivers disabled,
1394b differential output voltage
Drivers enabled, speed signaling off
MIN
TYP
172
400
–1.05†
550
–4.84‡
–12.4‡
See Figure 1
MAX
UNIT
265
mV
800
1.05†
mV
–2.53‡
–8.10‡
mA
20
mV
mA
mA
† Limits defined as algebraic sum of TPA+ and TPA– driver currents. Limits also apply to TPB+ and TPB– algebraic sum of driver currents.
‡ Limits defined as absolute limit of each of TPB+ and TPB– driver currents.
receiver
PARAMETER
TEST CONDITION
ZID
Differential impedance
Drivers disabled
ZIC
Common mode impedance
Common-mode
Drivers disabled
VTH–R
VTH–CB
Receiver input threshold voltage
Drivers disabled
Cable bias detect threshold, TPBx cable inputs
Drivers disabled
VTH+
VTH–
Positive arbitration comparator threshold voltage
VTH–SP200
VTH–SP400
MIN
TYP
4
7
MAX
UNIT
kΩ
4
20
pF
kΩ
24
pF
–30
30
mV
0.6
1.0
V
Drivers disabled
89
168
mV
Negative arbitration comparator threshold voltage
Drivers disabled
–168
–89
mV
Speed signal threshold
TPBIAS–TPA common mode
voltage, drivers disabled
49
131
mV
314
396
mV
MAX
UNIT
Speed signal threshold
device
PARAMETER
IDD
VTH
TEST CONDITION
MIN
TYP
Supply current 3.3 VDD
See Note 2
Power status threshold, CPS input†
400-kΩ resistor†
4.7
VOH
High-level output voltage, CTL0, CTL1, D0–D7, PCLK,
S5_LKON_DS2 outputs
VDD = 3 to 3.6 V,
IOH = –4 mA
2.8
VOL
Low-level output voltage, CTL0, CTL1, D0–D7, PCLK,
S5_LKON_DS2 outputs
IOL = 4 mA
IBH+
Positive peak bus holder current, D0–D7, CTL0–CTL1, LREQ
VDD = 3.6 V,
VI = 0 V to VDD
0.05
1
mA
IBH–
Negative peak bus holder current, D0–D7, CTL0–CTL1, LREQ
VDD = 3.6 V,
VI = 0 V to VDD
–1.0
–0.05
mA
IOZ
Off-state output current, CTL0, CTL1, D0–D7, S5_LKON_DS2
I/Os
VO = VDD or 0 V
±5
µA
–90
–20
µA
1.665
2.015
V
IIRST
VO
Pullup current, RESETz input
VI = 1.5 V or 0 V
At rated IO current
TPBIAS output voltage
75
mA
7.5
V
V
0.4
V
† Measured at cable power side of resistor.
‡ This parameter applicable only when ISO low.
NOTE 2: Repeat Max Packet (1 port receiving maximum size isochronous packet—4096 bytes, sent on every isochronous interval, data value
of 0xCCCCCCCCh; 2 ports repeating; all ports with S400 beta-mode connection), VDD3.3 = 3.3 V, internal regulator, TA = 25_C
16
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
electrical characteristics over recommended ranges of operating conditions (unless otherwise noted)
(continued)
thermal characteristics
PARAMETER
TEST CONDITION
RθJA
Junction-to-free-air thermal resistance
RθJC
Junction-to-case-thermal resistance
RθJA
Junction-to-free-air thermal resistance
RθJC
Junction-to-case-thermal resistance
RθJA
Junction-to-free-air thermal resistance
RθJC
Junction-to-case-thermal resistance
MIN
TYP
MAX
UNIT
Board mounted, No air flow, High conductivity TI
recommended test board,
board chip soldered or greased to
thermal land with 2 oz. copper
19.04
°C/W
0.17
°C/W
Board mounted, No air flow, High conductivity TI
recommended test board with thermal land but no solder
or grease thermal connection to thermal land with 2 oz.
copper
31.52
°C/W
0.17
°C/W
Board mounted, No air flow, High conductivity JEDEC
test board with 1 oz. copper
49.17
°C/W
3.11
°C/W
switching characteristics
PARAMETER
TEST CONDITION
tr
tf
TP differential rise time, transmit
tsu
Setup time, CTL0, CTL1, D1–D7, LREQ to
PCLK
1394a-2000
th
Hold time, CTL0, CTL1, D1–D7, LREQ
after PCLK
tsu
MIN
TYP
MAX
UNIT
10% to 90%,
At 1394 connector
0.3
0.8
ns
90% to 10%,
At 1394 connector
0.3
0.8
ns
50% to 50%,
See Figure 2
2.5
ns
1394a-2000
50% to 50%,
See Figure 2
0
ns
Setup time, CTL0, CTL1, D1–D7, LREQ to
LCLK_PMC
1394b
50% to 50%,
See Figure 2
2.5
ns
th
Hold time, CTL0, CTL1, D1–D7, LREQ
after LCLK_PMC
1394b
50% to 50%,
See Figure 2
0
ns
td
Delay time, PCLK to CTL0, CTL1, D1–D7,
PINT
1394a-2000
and 1394b
50% to 50%,
See Figure 3
0.5
TP differential fall time, transmit
7
ns
PARAMETER MEASUREMENT INFORMATION
TPAx+
TPBx+
56 Ω
TPAx–
TPBx–
Figure 1. Test Load Diagram
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
17
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PARAMETER MEASUREMENT INFORMATION
xCLK
tsu
th
D, CTL, LREQ
Figure 2. Dx, CTLx, LREQ Input Setup and Hold Time Waveforms
xCLK
td
D, CTL
Figure 3. Dx and CTLx Output Delay Relative to xCLK Waveforms
APPLICATION INFORMATION
Please obtain from the TI website or your local TI representative the reference schematics, reference layouts,
debug documents, and software recommendations for the TSB41BA3.
internal register configuration
There are 16 accessible internal registers in the TSB41BA3. The configuration of the registers at addresses 0h
through 7h (the base registers) is fixed, while the configuration of the registers at addresses 8h through Fh (the
paged registers) is dependent upon which 1 of 8 pages, numbered 0h through 7h, is currently selected. The
selected page is set in base register 7h. Note that while this register set is compatible with 1394a-2000 register
sets, some fields have been redefined and this register set contains additional fields.
Table 2 shows the configuration of the base registers, and Table 3 gives the corresponding field descriptions.
The base register field definitions are unaffected by the selected page number.
A reserved register or register field (marked as Reserved or Rsvd in the following register configuration tables)
is read as 0, but is subject to future usage. All registers in address pages 2 through 6 are reserved.
18
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
APPLICATION INFORMATION
Table 2. Base Register Configuration
BIT POSITION
Address
0
1
2
0000
3
4
5
Physical ID
0001
RHB
IBR
Extended (111b)
0011
PHY_Speed (111b)
LCtrl
C
0101
WDIE
ISBR
7
CPS
Gap_Count
0010
0100
6
R
Num_Ports (0011b)
SREN
Delay (0000b)
Jitter (000b)
CTOI
CPSI
0110
Max Legacy SPD
BLINK
0111
Page_Select
Rsvd
Pwr_Class
STOI
PEI
EAA
Bridge
EMC
Rsvd
Port_Select
Table 3. Base Register Field Descriptions
FIELD
SIZE
TYPE
DESCRIPTION
Physical ID
6
Rd
This field contains the physical address ID of this node determined during self-ID. The physical-ID is invalid after
a bus reset until the self-ID has completed as indicated by an unsolicited register 0 status transfer from the PHY
to the LLC.
R
1
Rd
Root. This bit indicates that this node is the root node. The R bit is reset to 0 by bus reset, and is set to 1 during
tree-ID if this node becomes root.
CPS
1
Rd
Cable-power-status. This bit indicates the state of the CPS input terminal. The CPS terminal is normally tied to
serial bus cable power through a 400-kΩ resistor. A 0 in this bit indicates that the cable power voltage has
dropped below its threshold for ensured reliable operation.
RHB
1
Rd/Wr
Root-holdoff bit. This bit instructs the PHY to attempt to become root after the next bus reset. The RHB bit is reset
to 0 by a hardware reset, and is unaffected by a bus reset. If two nodes on a single bus have their root holdoff bit
set, then the result is not defined. To prevent two nodes from having their root-holdoff bit set, this bit must only be
written using a PHY configuration packet.
IBR
1
Rd/Wr
Initiate bus reset. This bit instructs the PHY to initiate a long (166 µs) bus reset at the next opportunity. Any
receive or transmit operation in progress when this bit is set completes before the bus reset is initiated. The IBR
bit is reset to 0 after a hardware reset or a bus reset. Care must be exercised when writing to this bit to not change
the other bits in this register. It is recommended that whenever possible a bus reset be initiated using the ISBR bit
and not the IBR bit.
Gap_Count
6
Rd/Wr
Arbitration gap count. This value sets the subaction (fair) gap, arb-reset gap, and arb-delay times. The gap count
can be set either by a write to the register, or by reception or transmission of a PHY_CONFIG packet. The gap
count is reset to 3Fh by hardware reset or after two consecutive bus resets without an intervening write to the gap
count register (either by a write to the PHY register or by a PHY_CONFIG packet). It is strongly recommended
that this field only be changed using PHY configuration packets.
Extended
3
Rd
Extended register definition. For the TSB41BA3, this field is 111b, indicating that the extended register set is
implemented.
Num_Ports
4
Rd
Number of ports. This field indicates the number of ports implemented in the PHY. For the TSB41BA3 this field is
3.
PHY_Speed
3
Rd
PHY speed capability. This field is no longer used. For the TSB41BA3 PHY this field is 111b. Speeds for 1394b
PHYs must be checked on a port-by-port basis.
SREN
1
Rd/Wr
Standby/restore enable. This bit when set to 1 enables the port to go into the standby reduced power state when
commanded by a Standby PHY command packet. This enable works for all ports of the local device. Note the
1394b standard only allows leaf (one port connected) nodes to be placed into standby mode.
Delay
4
Rd
PHY repeater data delay. This field indicates the worst case repeater data delay of the PHY, expressed as
144+(delay × 20) ns. For the TSB41BA3 this field is 0.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
19
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
APPLICATION INFORMATION
Table 3. Base Register Field Descriptions (Continued)
SIZE
TYPE
DESCRIPTION
LCtrl
FIELD
1
Rd/Wr
Link-active status control. This bit controls the indicated active status of the LLC reported in the self-ID packet.
The logical AND of this bit and the LPS active status is replicated in the L field (bit 9) of the self-ID packet. The
LLC bit in the node self-ID packet is set active only if both the LPS input is active and the LCtrl bit is set.
The LCtrl bit provides a software controllable means to indicate the LLC self-ID active status in lieu of using the
LPS input terminal.
The LCtrl bit is set to 1 by hardware reset and is unaffected by bus-reset.
NOTE: The state of the PHY-LLC interface is controlled solely by the LPS input, regardless of the state of the
LCtrl bit. If the PHY-LLC interface is operational as determined by the LPS input being active, then received
packets and status information continue to be presented on the interface, and any requests indicated on the
LREQ input are processed, even if the LCtrl bit is cleared to 0.
C
1
Rd/Wr
Contender status. This bit indicates that this node is a contender for the bus or isochronous resource manager.
This bit is replicated in the c field (bit 20) of the self-ID packet. This bit is set to 0 on hardware reset. After
hardware reset, this bit may only be set via a software register write. This bit is unaffected by a bus reset.
Jitter
3
Rd
PHY repeater jitter. This field indicates the worst case difference between the fastest and slowest repeater data
delay, expressed as (jitter+1) × 20 ns. For the TSB41BA3, this field is 0.
Pwr_Class
3
Rd/Wr
Node power class. This field indicates this node power consumption and source characteristics and is
replicated in the pwr field (bits 21–23) of the self-ID packet. This field is reset to the state specified by the S5–S0
input terminals upon a hardware reset, and is unaffected by a bus reset. See Table 1 and Table 10.
WDIE
1
Rd/Wr
Watchdog interrupt enable. This bit, if set to 1, enables the port event interrupt (PIE) bit to be set whenever
resume operations begin on any port, or when any of the CTOI, CPSI, or STOI interrupt bits are set and the link
interface is nonoperational. This bit is reset to 0 by hardware reset and is unaffected by bus reset.
ISBR
1
Rd/Wr
Initiate short arbitrated bus reset. This bit, if set to 1, instructs the PHY to initiate a short (1.3 µs) arbitrated bus
reset at the next opportunity. This bit is reset to 0 by a bus reset. It is recommended that short bus reset is the
only reset type initiated by software. IEC 61883-6 requires that a node initiate short bus resets to minimize any
disturbance to an audio stream.
NOTE: Legacy IEEE Std 1394-1995 compliant PHYs are not capable of performing short bus resets.
Therefore, initiation of a short bus reset in a network that contains such a legacy device results in a long bus
reset being performed.
CTOI
1
Rd/Wr
Configuration time-out interrupt. This bit is set to 1 when the arbitration controller times out during tree-ID start,
and may indicate that the bus is configured in a loop. This bit is reset to 0 by hardware reset, or by writing a 1 to
this register bit.
If the CTOI and WDIE bits are both set and the LLC is or becomes inactive, then the PHY activates the
S5_LKON_DS2 output to notify the LLC to service the interrupt.
NOTE: If the network is configured in a loop, then only those nodes which are part of the loop generate a
configuration-timeout interrupt. All other nodes instead time out waiting for the tree-ID and/or self-ID process to
complete and then generate a state time-out interrupt and bus-reset. This bit is only set when the bus topology
includes 1394a nodes; otherwise, 1394b loop healing prevents loops from being formed in the topology.
CPSI
1
Rd/Wr
Cable power status interrupt. This bit is set to 1 whenever the CPS input transitions from high to low indicating
that cable power may be too low for reliable operation. This bit is reset to 1 by hardware reset. It can be cleared
by writing a 1 to this register bit.
If the CPSI and WDIE bits are both set and the LLC is or becomes inactive, then the PHY activates the
S5_LKON_DS2 output to notify the LLC to service the interrupt.
STOI
1
Rd/Wr
State-timeout interrupt. This bit indicates that a state time-out has occurred (which also causes a bus-reset to
occur). This bit is reset to 0 by hardware reset, or by writing a 1 to this register bit.
If the STOI and WDIE bits are both set and the LLC is or becomes inactive, then the PHY activates the
S5_LKON_DS2 output to notify the LLC to service the interrupt.
PEI
1
Rd/Wr
Port event interrupt. This bit is set to 1 on any change in the connected, bias, disabled, or fault bits for any port
for which the port interrupt enable (PIE) bit is set. Additionally, if the resuming port interrupt enable (WDIE) bit is
set, then the PEI bit is set to 1 at the start of resume operations on any port. This bit is reset to 0 by hardware
reset, or by writing a 1 to this register bit.
20
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
APPLICATION INFORMATION
Table 3. Base Register Field Descriptions (Continued)
SIZE
TYPE
DESCRIPTION
EAA
FIELD
1
Rd/Wr
Enable accelerated arbitration. This bit enables the PHY to perform the various arbitration acceleration
enhancements defined in 1394a-2000 (ACK-accelerated arbitration, asynchronous fly-by concatenation, and
isochronous fly-by concatenation). This bit is reset to 0 by hardware reset and is unaffected by bus reset. This
bit has no effect when the device is operating in 1394b mode.
NOTE: The use of accelerated arbitration is completely compatible with networks containing legacy IEEE Std
1394-1995 PHYs. The EAA bit is set only if the attached LLC is 1394a-2000 compliant. If the LLC is not
1394a-2000 or 1394b-2002 compliant, then the use of the arbitration acceleration enhancements can interfere
with isochronous traffic by excessively delaying the transmission of cycle-start packets.
EMC
1
Rd/Wr
Enable multispeed concatenated packets. This bit enables the PHY to transmit concatenated packets of
differing speeds in accordance with the protocols defined in 1394a-2000. This bit is reset to 0 by hardware reset
and is unaffected by bus reset. This bit has no effect when the device is operating in 1394b mode.
NOTE: The use of multispeed concatenation is completely compatible with networks containing legacy IEEE
Std 1394-1995 PHYs. However, use of multispeed concatenation requires that the attached LLC be
1394a-2000 or 1394b-2002 compliant.
Max Legacy
SPD
3
Rd
Maximum legacy-path speed. This field holds the maximum speed capability of any legacy node (1394a-2000
or 1394-1995 compliant) as indicated in the self-ID packets received during bus-initialization. Encoding is the
same as for the PHY_SPEED field (but limited to S400 maximum).
BLINK
1
Rd
Beta-mode link. This bit indicates that a beta-mode capable link is attached to the PHY. This bit is set by the
BMODE input terminal on the TSB41BA3.
Bridge
2
Rd/Wr
This field controls the value of the bridge (brdg) field in self-ID packet. The power reset value is 0. Details for
when to set these bits are specified in the IEEE 1394.1 bridging specification.
Page_Select
3
Rd/Wr
Page_Select. This field selects the register page to use when accessing register addresses 8 through 15. This
field is reset to 0 by a hardware reset and is unaffected by bus-reset.
Port_Select
4
Rd/Wr
Port_Select. This field selects the port when accessing per-port status or control (for example, when one of the
port status/control registers is accessed in page 0). Ports are numbered starting at 0. This field is reset to 0 by
hardware-reset and is unaffected by bus-reset.
The port status page provides access to configuration and status information for each of the ports. The port is
selected by writing 0 to the Page_Select field and the desired port number to the Port_Select field in base
register 7. Table 4 shows the configuration of the port status page registers, and Table 5 gives the corresponding
field descriptions. If the selected port is unimplemented, then all registers in the port status page are read as
0.
Table 4. Page 0 (Port Status) Register Configuration
BIT POSITION
Address
0
1
1000
Astat
1001
Negotiated_speed
2
3
4
Ch
Con
RXOK
Dis
PIE
Fault
Standby_fault
Disscrm
B_Only(0)
BStat
5
6
1010
DC_connected
Max_port_speed
LPP
Cable_speed
1011
Connection_unreliable
Reserved
Beta_mode
Reserved
1100
1101
7
Port_error
Reserved
Sleep_Flag
Sleep_enable
1110
Reserved
1111
Reserved
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
Loop_disable
In_standby
Hard_disable
21
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
APPLICATION INFORMATION
Table 5. Page 0 (Port Status) Register Field Descriptions
FIELD
SIZE
TYPE
DESCRIPTION
Astat
2
Rd
TPA line state. This field indicates the instantaneous TPA line state of the selected port, encoded
as follows:
Code
Arb Value
11
Z
01
1
10
0
00
invalid
Bstat
2
Rd
TPB line state. This field indicates the TPB line state of the selected port. This field has the same
encoding as the AStat field.
Ch
1
Rd
Child/parent status. A 1 indicates that the selected port is a child port. A 0 indicates that the selected
port is the parent port. A disconnected, disabled, or suspended port is reported as a child port. The
Ch bit is invalid after a bus-reset until tree-ID has completed.
Con
1
Rd
Debounced port connection status. This bit indicates that the selected port is connected. The
connection must be stable for the debounce time of approximately 341 ms for the Con bit to be set
to 1. The Con bit is reset to 0 by hardware reset and is unaffected by bus-reset.
NOTE: The Con bit indicates that the port is physically connected to a peer PHY, but this does not
mean that the port is necessarily active. For 1394b-coupled connections, the Con bit is set when a
port detects connection tones from the peer PHY and operating speed negotiation is completed.
RxOK
1
Rd
Receive OK. In 1394a-2000 mode this bit indicates the reception of a debounced TPBias signal. In
Beta_mode, this bit indicates the reception of a continuous electrically valid signal.
Note: RxOK is set to false during the time that only connection tones are detected in beta mode.
Dis
1
Rd/Wr
Port disabled control. If this bit is 1, then the selected port is disabled. The Dis bit is reset to 0 by
hardware reset (all ports are enabled for normal operation following hardware reset). The Dis bit is
not affected by bus-reset. When this bit is set, the port cannot become active; however, the port still
tones, but does not establish an active connection.
Negotiated_speed
3
Rd
Indicates the maximum speed negotiated between this PHY port and its immediately connected port.
The encoding is as for Max_port_speed. It is set on connection when in Beta_mode, or to a value
established during self-ID when in 1394a-2000 mode.
PIE
1
Rd/Wr
Port event interrupt enable. When this bit is 1, a port event on the selected port sets the port event
interrupt (PEI) bit and notifies the link. This bit is reset to 0 by a hardware reset, and is unaffected
by bus-reset.
Fault
1
Rd/Wr
Fault. This bit indicates that a resume-fault or suspend-fault has occurred on the selected port, and
that the port is in the suspended state. A resume-fault occurs when a resuming port fails to detect
incoming cable bias from its attached peer. A suspend-fault occurs when a suspending port
continues to detect incoming cable bias from its attached peer. Writing 1 to this bit clears the Fault
bit to 0. This bit is reset to 0 by hardware reset and is unaffected by bus-reset.
Standby_fault
1
Rd/Wr
This bit is set to 1 if an error is detected during a standby operation and cleared on exit from the
standby state. A write of 1 to this bit or receipt of the appropriate remote command packet clears it
to 0. When this bit is cleared, standby errors are cleared.
Disscrm
1
Rd/Wr
Disable scrambler. If this bit is set to 1, then the data sent during packet transmission is not
scrambled.
B_Only
1
Rd
Beta-mode operation only. For the TSB41BA3, this bit is set to 0 for all ports when all ports are
programmed as bilingual or a combination of bilingual and data-strobe (1394a) only. If a port has
been programmed to be beta-only at a selected speed (for example B1 is beta-only S100), then this
bit is set to 1.
DC_connected
1
Rd
If this bit is set to 1, the port has detected a dc connection to the peer port by means of a 1394a-style
connect detect circuit.
22
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
APPLICATION INFORMATION
Table 5. Page 0 (Port Status) Register Field Descriptions (Continued)
SIZE
TYPE
DESCRIPTION
Max_port_speed
FIELD
3
Rd/Wr
Max_port_speed
The maximum speed at which a port is allowed to operate in beta mode. The encoding is:
000 = S100
001 = S200
010 = S400
011 = S800
100 = S1600
101 = S3200
110 = reserved
111 = reserved
An attempt to write to the register with a value greater than the hardware capability of the port results
in the maximum value that the port is capable of being stored in the register. The port uses this
register only when a new connection is established in the beta mode when a port is programmed
as a beta-only port. When a port is programmed as a bilingual port, it is fixed at S400 for the beta
speed and is not updated by a write to this register. The power reset value is the maximum speed
capable of the port. Software may modify this value to force a port to train at a lower than maximum
(when in a beta-only mode), but no lower than minimum speed.
LPP
(Local_plug_present)
1
Rd
This flag is set permanently to 1.
Cable_speed
3
Rd
This variable is set to the maximum speed that the port is capable of. The encoding is the same as
for Max_port_speed.
Connection_unreliable
1
Rd/Wr
If this bit is set to 1, then a beta mode speed negotiation has failed or synchronization has failed. A
write of 1 to this field resets the value to 0.
Beta_mode
1
Rd
Operating in beta mode. If this bit is 1, the port is operating in beta mode; it is equal to 0 otherwise
(that is, when operating in 1394a-2000 mode, or when disconnected). If Con is 1, RxOK is 1, and
Beta_mode is 0, then the port is active and operating in the 1394a-2000 mode.
Port_error
8
Rd/Wr
Incremented whenever the port receives an invalid codeword, unless the value is already 255.
Cleared when read (including being read by means of a remote access packet). Intended for use
by a single bus-wide diagnostic program.
Sleep_Flag
1
Rd
This bit is set to 1 if the port is in the sleep state. The transition to the sleep state occurs only if the
port has been enabled for the sleep mode.
Sleep_enable
1
Rd/Wr
This bit is set to 1 if the port has been enabled for sleep mode. If SLPEN pin is sampled high during
reset, then this bit is set high for all ports. If sampled low, then it is 0. Software may individually enable
or disasble sleep mode for a port by writing to this bit. Sleep mode operation is described in IDB–1394
specification. In PMC mode when no link is present the sleep state of each port can be monitored
on the data lines as described in the Terminal Functions table entry for LCLK_PMC.
Loop_disable
1
Rd
This bit is set to 1 if the port has been placed in the loop disable state as part of the loop free build
process (the PHYs at either end of the connection are active, but if the connection itself were
activated, then a loop would exist). Cleared on bus reset and on disconnection.
In_standby
1
Rd
This bit is set to 1 if the port is in standby power-management state.
Hard_disable
1
Rd/Wr
No effect unless the port is disabled. If this bit is set to 1, the port does not maintain connectivity status
on an ac connection when disabled. The values of the Con and RxOK bits are forced to 0. This flag
can be used to force renegotiation of the speed of a connection. It can also be used to place the
device into a lower power state since when hard disabled, a port no longer tones to maintain 1394b
ac-connectivity status.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
23
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
APPLICATION INFORMATION
The vendor identification page identifies the vendor/manufacturer and compliance level. The page is selected
by writing 1 to the Page_Select field in base register 7. Table 6 shows the configuration of the vendor
identification page, and Table 7 shows the corresponding field descriptions.
Table 6. Page 1 (Vendor ID) Register Configuration
BIT POSITION
Address
0
1
2
3
4
1000
Compliance
1001
Reserved
1010
Vendor_ID[0]
1011
Vendor_ID[1]
1100
Vendor_ID[2]
1101
Product_ID[0]
1110
Product_ID[1]
1111
Product_ID[2]
5
6
7
Table 7. Page 1 (Vendor ID) Register Field Descriptions
FIELD
SIZE
TYPE
DESCRIPTION
Compliance
8
Rd
Compliance level. For the TSB41BA3 this field is 02h, indicating compliance with the 1394b-2002 specification.
Vendor_ID
24
Rd
Manufacturer’s organizationally unique identifier (OUI). For the TSB41BA3 this field is 08_00_28h (Texas
Instruments) (the MSB is at register address 1010b).
Product_ID
24
Rd
Product identifier. For the TSB41BA3 this field is 83_30_01h (the MSB is at register address 1101b).
The vendor-dependent page provides access to the special control features of the TSB41BA3, as well as
configuration and status information used in manufacturing test and debug. This page is selected by writing 7
to the Page_Select field in base register 7. Table 8 shows the configuration of the vendor-dependent page, and
Table 9 shows the corresponding field descriptions.
Table 8. Page 7 (Vendor-Dependent) Register Configuration
BIT POSITION
Address
0
1000
1
2
3
4
5
6
Reserved
Reserved
1001
Reserved for test
1010
Reserved for test
1011
Reserved for test
1100
Reserved for test
1101
7
Reserved for test
1110
SWR
1111
Reserved for test
Reserved for test
Table 9. Page 7 (Vendor-Dependent) Register Field Descriptions
FIELD
SWR
24
SIZE
1
TYPE
Rd/Wr
DESCRIPTION
Software hard reset. Writing a 1 to this bit forces a hard reset of the PHY (same effect as momentarily
asserting the RESETz terminal low). This bit is always read as a 0.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
APPLICATION INFORMATION
power-class programming
The S2_PC0, S1_PC1, and S2_PC2 terminals can be used in some port speed/mode selections to set the
default value of the power-class indicated in the pwr field (bits 21–23) of the transmitted self-ID packet.
Descriptions of the various power-classes are given in Table 10. The default power-class value is loaded
following a hardware reset, but is overridden by any value subsequently loaded into the Pwr_Class field in
register 4.
Table 10. Power Class Descriptions
PC0–PC2
DESCRIPTION
000
Node does not need power and does not repeat power.
001
Node is self-powered and provides a minimum of 15 W to the bus.
010
Node is self-powered and provides a minimum of 30 W to the bus.
011
Node is self-powered and provides a minimum of 45 W to the bus.
100
Node may be powered from the bus and is using up to 3 W, no additional power is needed to enable the link. The node may also
provide power to the bus. The amount of bus power that it provides can be found in the configuration ROM.
101
Reserved for future standardization.
110
Node is powered from the bus and uses up to 3 W. An additional 3 W is needed to enable the link.
111
Node is powered from the bus and uses up to 3 W. An additional 7 W is needed to enable the link.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
25
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
APPLICATION INFORMATION
power-class programming (continued)
Outer Shield
Termination
TSB41BA3
400 kΩ
CPS
VP
Cable
Power
Pair
270 µF
TPBIAS
56 Ω
1 µF
56 Ω
TPA+
Cable
Pair
A
TPA–
0.1 µF
1 MΩ
Cable Port
TPB+
Cable
Pair
B
TPB–
56 Ω
56 Ω
VG
270 pF
(see Note A)
5 kΩ
NOTE A: The IEEE Std 1394-1995 calls for a 250-pF capacitor, which is a nonstandard component value. A 270-pF capacitor is recommended.
Figure 4. Typical TP Cable Connections
Outer Cable Shield
1 MΩ
0.01 µF
0.001 µF
Chassis Ground
Figure 5. Typical DC Isolated Outer Shield Termination
26
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
APPLICATION INFORMATION
power-class programming (continued)
Outer Cable Shield
Chassis Ground
Figure 6. Non-DC Isolated Outer Shield Termination
10 kΩ
Link Power
LPS
Square Wave Input
LPS
10 kΩ
Figure 7. Nonisolated Connection Variations for LPS
PHY VDD
18 kΩ
LPS
Square Wave Signal
0.033 µF
13 kΩ
PHY GND
Figure 8. Isolated Circuit Connection for LPS
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
27
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
APPLICATION INFORMATION
designing with PowerPAD
The TSB41BA3 is housed in a high performance, thermally enhanced, 80-terminal PFP PowerPAD package.
Use of the PowerPAD package does not require any special considerations except to note that the PowerPAD,
which is an exposed die pad on the bottom of the device, is a metallic thermal and electrical conductor.
Therefore, if not implementing PowerPAD PCB features, the use of solder masks (or other assembly
techniques) may be required to prevent any inadvertent shorting by the exposed PowerPAD of connection
etches or vias under the package. The recommended option, however, is to not run any etches or signal vias
under the device, but to have only a grounded thermal land as explained below. Although the actual size of the
exposed die pad may vary, the maximum size required for the keepout area for the 80-terminal PFP PowerPAD
package is 10 mm × 10 mm. The actual PowerPAD size for the TSB41BA3 is 6 mm × 6 mm.
It is recommended that there be a thermal land, which is an area of solder-tinned-copper, underneath the
PowerPAD package. The thermal land varies in size, depending on the PowerPAD package being used, the
PCB construction, and the amount of heat that needs to be removed. In addition, the thermal land may or may
not contain numerous thermal vias depending on PCB construction.
Other requirements for thermal lands and thermal vias are detailed in the TI application note PowerPAD
Thermally Enhanced Package Application Report, (SLMA002), available via the TI Web pages at URL:
http://www.ti.com.
Figure 9. Example of a Thermal Land for the TSB41BA3 PHY
For the TSB41BA3, this thermal land must be grounded to the low impedance ground plane of the device. This
improves not only thermal performance but also the electrical grounding of the device. It is also recommended
that the device ground terminal landing pads be connected directly to the grounded thermal land. The land size
ought to be as large as possible without shorting device signal terminals. The thermal land may be soldered
to the exposed PowerPAD using standard reflow soldering techniques.
While the thermal land may be electrically floated and configured to remove heat to an external heat sink, it is
recommended that the thermal land be connected to the low impedance ground plane for the device. More
information may be obtained from the TI application note PHY Layout, (SLLA020).
PowerPAD is a trademark of Texas Instruments.
28
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
APPLICATION INFORMATION
using the TSB41BA3 with a 1394-1995 or 1394a-2000 link layer
The TSB41BA3 implements the PHY-LLC interface specified in the 1394b Supplement. This interface is based
upon the interface described in Section 17 of IEEE 1394b-2002. When using a LLC compliant with this interface,
the BMODE input must be tied high.
The TSB41BA3 also functions with a LLC that is compliant with the older 1394 standards. This interface is
compatible with both the older Annex J interface specified in the IEEE Std 1394-1995 (with the exception of the
Annex J isolation interfacing method) and the PHY-LLC interface specified in 1394a-2000. When using a LLC
compliant with this interface, the BMODE input must be tied low.
When the BMODE input is tied low, the TSB41BA3 implements the PHY-LLC interface specified in the
1394a-2000 Supplement. This interface is based upon the interface described in informative Annex J of IEEE
Std 1394-1995, which is the interface used in the oldest TI PHY devices. The PHY-LLC interface specified in
1394a-2000 is compatible with the older Annex J. However, the TSB41BA3 does not support the Annex J
isolation interfacing method. When implementing the 1394a-2000 interface, certain signals are not used:
–
The PINT output (terminal 1) may be left open
–
The LCLK_PMC input (terminal 7) must be tied directly to ground or through a pulldown resistor of ~1 kΩ
or less, unless the PMC mode is desired (see LCLK_PMC terminal description).
All other signals are connected to their counterparts on the 1394a link-layer controller. The PCLK output
corresponds to the SCLK input signal on most LLCs.
The 1394a-2000 Supplement includes enhancements to the Annex J interface that should be comprehended
when using the TSB41BA3 with a 1394-1995 LLC device.
D A new LLC service request was added which allows the LLC to temporarily enable and disable
asynchronous arbitration accelerations. If the LLC does not implement this new service request, then the
arbitration enhancements must not be enabled (see the EAA bit in PHY register 5).
D The capability to perform multispeed concatenation (the concatenation of packets of differing speeds) was
added in order to improve bus efficiency (primarily during isochronous transmission). If the LLC does not
support multispeed concatenation, then multispeed concatenation must not be enabled in the PHY (see the
EMC bit in PHY register 5).
D In order to accommodate the higher transmission speeds expected in future revisions of the standard,
1394a-2000 extended the speed code in bus requests from 2 bits to 3 bits, increasing the length of the bus
request from 7 bits to 8 bits. The new speed codes were carefully selected so that new 1394a-2000 PHY
and LLC devices would be compatible, for speeds from S100 to S400, with legacy PHY and LLC devices
that use the 2-bit speed codes. The TSB41BA3 correctly interprets both 7-bit bus requests (with 2-bit speed
code) and 8-bit bus requests (with 3-bit speed codes). Moreover, if a 7-bit bus request is immediately
followed by another request (for example, a register read or write request), then the TSB41BA3 correctly
interprets both requests. Although the TSB41BA3 correctly interprets 8-bit bus requests, a request with a
speed code exceeding S400 while in 1394a-2000 PHY-link interface mode results in the TSB41BA3
transmitting a null packet (data-prefix followed by data-end, with no data in the packet).
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
29
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
APPLICATION INFORMATION
power-up reset
To ensure proper operation of the TSB41BA3 the RESETz terminal must be asserted low for a minimum of 2 ms
from the time that PHY power reaches the minimum required supply voltage and the input clock to the PHY is
valid. When using a passive capacitor on the RESETz terminal to generate a power-on reset signal, the
minimum reset time is assured if the value of the capacitor satisfies the following equation (the value must be
no smaller than approximately 0.1 µF):
Cmin = 0.0077 * T + 0.085 + (external_oscillator_start–up_time * 0.05)
Where Cmin is the minimum capacitance on the RESETz terminal in µF, T is the VDD ramp time, 10%–90%, in
ms, external_oscillator_start–up_time is the time from power applied to the external oscillator until the oscillator
outputs a valid clock in ms. If a crystal is used rather than an oscillator, then the external_oscillator_start-up_time
may be set to 0.
For example with a 2–ms power ramp time and a 2-ms oscillator startup time:
Cmin = 0.0077 * 2 + 0.085 + (2 * 0.05) = 0.2 µF
It is appropriate to select the nearest standard value capacitor that exceeds this value, for example 0.22 µF.
Or with a 2-ms power ramp time and a 49.152-MHz fundamental crystal:
Cmin = 0.0077 * 2 + 0.085 + (0 * 0.05) = 0.1 µF
crystal oscillator selection
The TSB41BA3 and other TI PHY devices are designed to use an external 49.152-MHz crystal connected
between the XI and XO terminals to provide the reference for an internal oscillator circuit. This oscillator in turn
drives a PLL circuit that generates the various clocks required for transmission and resynchronization of data
at the S100 through S400 media data rates.
A variation of less than ±100 ppm from nominal for the media data rates is required by IEEE Std 1394. Adjacent
PHYs may therefore have a difference of up to 200 ppm from each other in their internal clocks, and PHYs must
be able to compensate for this difference over the maximum packet length. Larger clock variations may cause
resynchronization overflows or underflows, resulting in corrupted packet data or even PHY lockup.
For the TSB41BA3, the PCLK output may be used to measure the frequency accuracy and stability of the
internal oscillator and PLL from which it is derived. When operating the PHY-LLC interface with a non-1394b
LLC, the frequency of the PCLK output must be within ±100 ppm of the nominal frequency of 49.152 MHz. When
operating the PHY-LLC interface with a 1394b LLC, the frequency of the PCLK output must be within ±100 ppm
of the nominal frequency of 98.304 MHz.
The following are some typical specifications for crystals used with the physical layers from TI in order to achieve
the required frequency accuracy and stability:
D Crystal mode of operation: Fundamental
D Frequency tolerance at 25_C: Total frequency variation for the complete circuit is ±100 ppm. A crystal with
±30 ppm frequency tolerance is recommended for adequate margin.
D Frequency stability (over temperature and age): A crystal with ±30 ppm frequency stability is recommended
for adequate margin.
30
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
APPLICATION INFORMATION
NOTE:
The total frequency variation must be kept below ±100 ppm from nominal with some allowance for
error introduced by board and device variations. Trade-offs between frequency tolerance and
stability may be made as long as the total frequency variation is less than ±100 ppm. For example,
the frequency tolerance of the crystal may be specified at 50 ppm and the temperature tolerance
may be specified at 30 ppm to give a total of 80 ppm possible variation due to the oscillator alone.
Aging also contributes to the frequency variation.
D Load capacitance: For parallel resonant mode crystal circuits, the frequency of oscillation is dependent
upon the load capacitance specified for the crystal. Total load capacitance (CL) is a function of not only the
discrete load capacitors, but also board layout and circuit. It may be necessary to iteratively select discrete
load capacitors until the PCLK output is within specification. It is recommended that load capacitors with
a maximum of ±5% tolerance be used.
As an example, for the OHCI + 41LV03 evaluation module (EVM) which uses a crystal specified for 12 pF
loading, load capacitors (C9 and C10 in Figure 10) of 16 pF each were appropriate for the layout of that particular
board. The load specified for the crystal includes the load capacitors (C9, C10), the loading of the PHY terminals
(CPHY), and the loading of the board itself (CBD). The value of CPHY is typically about 1 pF, and CBD is typically
0.8 pF per centimeter of board etch; a typical board can have 3 pF to 6 pF or more. The load capacitors C9 and
C10 combine as capacitors in series so that the total load capacitance is:
C L + C9 C10 ) C PHY ) C BD
C9 ) C10
C9
X1
X1
49.152 MHz
IS
CPHY + CBD
X0
C10
Figure 10. Load Capacitance for the TSB41BA3 PHY
NOTE: The layout of the crystal portion of the PHY circuit is important for obtaining the correct
frequency, minimizing noise introduced into the PHY’s phase lock loop, and minimizing any
emissions from the circuit. The crystal and two load capacitors must be considered as a unit during
layout. The crystal and load capacitors must be placed as close as possible to one another while
minimizing the loop area created by the combination of the three components. Varying the size of
the capacitors may help in this. Minimizing the loop area minimizes the effect of the resonant current
(IS) that flows in this resonant circuit. This layout unit (crystal and load capacitors) must then be
placed as close as possible to the PHY XI and XO terminals to minimize trace lengths.
C9
C10
X1
Figure 11. Recommended Crystal and Capacitor Layout
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
31
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
APPLICATION INFORMATION
It is strongly recommended that part of the verification process for the design be to measure the frequency of
the PCLK output of the PHY. This should be done with a frequency counter with an accuracy of 6 digits or better.
If the PCLK frequency is more than the crystal’s tolerance from 49.152 MHz or 98.304 MHz, then the load
capacitance of the crystal may be varied to improve frequency accuracy. If the frequency is too high, add more
load capacitance; if the frequency is too low, decrease load capacitance. Typically, changes must be done to
both load capacitors (C9 and C10 above) at the same time, and both must be of the same value. Additional
design details and requirements may be provided by the crystal vendor.
bus reset
It is recommended, that whenever the user has a choice, the user should initiate a bus reset by writing to the
initiate short bus reset (ISBR) bit (bit 1 PHY register 0101b). Care must be taken to not change the value of any
of the other writeable bits in this register when the ISBR bit is written to.
In the TSB41BA3, the initiate bus reset (IBR) bit may be set to 1 in order to initiate a bus reset and initialization
sequence, however, it is recommended to use the ISBR bit instead. The IBR bit is located in PHY register 1 along
with the root-holdoff (RHB) bit and gap-count register. As required by the 1394b Supplement this configuration
maintains compatibility with older TI PHY designs which were based upon either the suggested register set
defined in Annex J of IEEE Std 1394-1995 or the 1394a-2000 Supplement. Therefore, whenever the IBR bit
is written, the RHB bit and gap-count are also necessarily written.
It is recommended that the RHB bit and gap-count only be updated by PHY configuration packets. The
TSB41BA3 is 1394a and 1394b compliant, and therefore both the reception and transmission of PHY
configuration packets cause the RHB and gap-count to be loaded, unlike older IEEE Std 1394-1995 compliant
PHYs which decode only received PHY configuration packets.
The gap-count is set to the maximum value of 63 after two consecutive bus resets without an intervening write
to the gap-count, either by a write to PHY register 1 or by a PHY configuration packet. This mechanism allows
a PHY configuration packet to be transmitted and then a bus reset to be initiated so as to verify that all nodes
on the bus have updated their RHB bits and gap-count values, without having the gap-count set back to 63 by
the bus reset. The subsequent connection of a new node to the bus, which initiates a bus reset, then causes
the gap-count of each node to be set to 63. Note, however, that if a subsequent bus reset is instead initiated
by a write to register 1 to set the IBR bit, then all other nodes on the bus have their gap-count values set to 63,
while this node’s gap-count remains set to the value just loaded by the write to PHY register 1.
Therefore, in order to maintain consistent gap-counts throughout the bus, the following rules apply to the use
of the IBR bit, RHB bit, and gap-count in PHY register 1:
D Following the transmission of a PHY configuration packet, a bus reset must be initiated in order to verify
that all nodes have correctly updated their RHB bits and gap-count values, and to ensure that a subsequent
new connection to the bus causes the gap-count to be set to 63 on all nodes in the bus. If this bus reset is
initiated by setting the IBR bit to 1, then the RHB bit and gap-count register must also be loaded with the
correct values consistent with the just transmitted PHY configuration packet. In the TSB41BA3, the RHB
bit and gap-count have been updated to their correct values upon the transmission of the PHY configuration
packet, and so these values may first be read from register 1 and then rewritten.
D Other than to initiate the bus reset which must follow the transmission of a PHY configuration packet,
whenever the IBR bit is set to 1 in order to initiate a bus reset, the gap-count value must also be set to 63
so as to be consistent with other nodes on the bus, and the RHB bit must be maintained with its current value.
D The PHY register 1 must not be written to except to set the IBR bit. The RHB bit and gap-count must not
be written without also setting the IBR bit to 1.
32
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
APPLICATION INFORMATION
bus reset (continued)
D To avoid these problems all bus resets initiated by software must be initiated by writing the ISBR bit (bit 1
PHY register 0101b). Care must be taken to not change the value of any of the other writeable bits in this
register when the ISBR bit is written to. Also, the only means to change the gap count of any node must
be by means of the PHY configuration packet, which changes all nodes to the same gap count.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
33
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394a-2000 INTERFACE)
The TSB41BA3 is designed to operate with an LLC such as the Texas Instruments TSB12LV21B, TSB12LV26,
TSB12LV32, TSB42AA4, or TSB12LV01B when the BMODE terminal is tied low. Details of operation for the
Texas Instruments LLC devices are found in the respective LLC data sheets. The following paragraphs describe
the operation of the PHY-LLC interface. This interface is formally defined in IEEE 1394a-2000, Section 5A.
The interface to the LLC consists of the PCLK, CTL0–CTL1, D0–D7, LREQ, LPS, and S5_LKON_DS2 terminals
on the TSB41BA3, as shown in Figure 12.
TSB41BA3
PCLK (SYSCLK)
CTL0–CTL1
Link-Layer
Controller
D0–D7
LREQ
LPS
S5_LKON_DS2
Figure 12. PHY-LLC Interface
The PCLK terminal provides a 49.152-MHz interface system clock. All control and data signals are synchronized
to, and sampled on, the rising edge of PCLK. This terminal serves the same function as the SYSCLK terminal
of 1394a-2000 compliant PHY devices.
The CTL0 and CTL1 terminals form a bidirectional control bus, which controls the flow of information and data
between the TSB41BA3 and LLC.
The D0–D7 terminals form a bidirectional data bus, which transfers status information, control information, or
packet data between the devices. The TSB41BA3 supports S100, S200, and S400 data transfers over the
D0–D7 data bus. In S100 operation only the D0 and D1 terminals are used; in S200 operation only the D0–D3
terminals are used; and in S400 operation all D0–D7 terminals are used for data transfer. When the TSB41BA3
is in control of the D0–D7 bus, unused Dn terminals are driven low during S100 and S200 operations. When
the LLC is in control of the D0–D7 bus, unused Dn terminals are ignored by the TSB41BA3.
The LREQ terminal is controlled by the LLC to send serial service requests to the PHY in order to request access
to the serial-bus for packet transmission, read or write PHY registers, or control arbitration acceleration.
The LPS and S5_LKON_DS2 terminals are used for power management of the PHY and LLC. The LPS terminal
indicates the power status of the LLC, and may be used to reset the PHY-LLC interface or to disable PCLK. The
S5_LKON_DS2 terminal sends a wake-up notification to the LLC or external circuitry and indicates an interrupt
to the LLC when either LPS is inactive or the PHY register L bit is 0.
The TSB41BA3 normally controls the CTL0–CTL1 and D0–D7 bidirectional buses. The LLC is allowed to drive
these buses only after the LLC has been granted permission to do so by the PHY.
34
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394a-2000 INTERFACE)
There are four operations that may occur on the PHY-LLC interface: link service request, status transfer, data
transmit, and data receive. The LLC issues a service request to read or write a PHY register, to request the PHY
to gain control of the serial-bus in order to transmit a packet, or to control arbitration acceleration.
The PHY may initiate a status transfer either autonomously or in response to a register read request from the
LLC.
The PHY initiates a receive operation whenever a packet is received from the serial-bus.
The PHY initiates a transmit operation after winning control of the serial-bus following a bus-request by the LLC.
The transmit operation is initiated when the PHY grants control of the interface to the LLC.
Table 11 and Table 12 show the encoding of the CTL0–CTL1 bus.
Table 11. CTL Encoding When PHY Has Control of the Bus
CTL0
CTL1
0
0
Idle
NAME
No activity (this is the default mode)
DESCRIPTION
0
1
Status
Status information is being sent from the PHY to the LLC.
1
0
Receive
An incoming packet is being sent from the PHY to the LLC.
1
1
Grant
The LLC has been given control of the bus to send an outgoing packet.
Table 12. CTL Encoding When LLC Has Control of the Bus
CTL0
CTL1
0
0
Idle
NAME
The LLC releases the bus (transmission has been completed)
DESCRIPTION
0
1
Hold
The LLC is holding the bus while data is being prepared for transmission, or indicating that another packet is to
be transmitted (concatenated) without arbitrating
1
0
Transmit
An outgoing packet is being sent from the LLC to the PHY
1
1
Reserved
None
LLC service request
To request access to the bus, to read or write a PHY register, or to control arbitration acceleration, the LLC sends
a serial bit stream on the LREQ terminal as shown in Figure 13.
LR0
LR1
LR2
LR3
LR (n-2)
LR (n-1)
Each cell represents one clock sample time, and n is the number of bits in the request stream.
Figure 13. LREQ Request Stream
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
35
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394a-2000 INTERFACE)
LLC service request (continued)
The length of the stream varies depending on the type of request as shown in Table 13.
Table 13. Request Stream Bit Length
REQUEST TYPE
NUMBER OF BITS
Bus request
7 or 8
Read register request
9
Write register request
17
Acceleration control request
6
Regardless of the type of request, a start bit of 1 is required at the beginning of the stream, and a stop bit of 0
is required at the end of the stream. The second through fourth bits of the request stream indicate the type of
the request. In the descriptions below, bit 0 is the most significant and is transmitted first in the request bit stream.
The LREQ terminal is normally low.
Table 14 shows the encoding for the request type.
Table 14. Request Type Encoding
LR1–LR3
NAME
DESCRIPTION
000
ImmReq
Immediate bus request. Upon detection of idle, the PHY takes control of the bus immediately without arbitration.
001
IsoReq
Isochronous bus request. Upon detection of idle, the PHY arbitrates for the bus without waiting for a subaction gap.
010
PriReq
Priority bus request. The PHY arbitrates for the bus after a subaction gap, ignores the fair protocol.
011
FairReq
Fair bus request. The PHY arbitrates for the bus after a subaction gap, follows the fair protocol.
100
RdReg
The PHY returns the specified register contents through a status transfer
101
WrReg
Write to the specified register
110
AccelCtl
Enable or disable asynchronous arbitration acceleration
111
Reserved
Reserved
For a bus request, the length of the LREQ bit stream is 7 or 8 bits as shown in Table 15.
Table 15. Bus Request
BIT(s)
0
NAME
DESCRIPTION
Start bit
Indicates the beginning of the transfer (always 1)
1–3
Request type
Indicates the type of bus request. See Table 14.
4–6
Request speed
Indicates the speed at which the PHY sends the data for this request. See Table 16 for the encoding of this field.
Stop bit
Indicates the end of the transfer (always 0). If bit 6 is 0, then this bit may be omitted.
7
Table 16 shows the 3-bit request speed field used in bus requests.
Table 16. Bus Request Speed Encoding
36
LR4–LR6
DATA RATE
000
S100
010
S200
100
S400
All Others
Invalid
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394a-2000 INTERFACE)
LLC service request (continued)
NOTE:
The TSB41BA3 accepts a bus request with an invalid speed code and processes the bus request
normally. However, during packet transmission for such a request, the TSB41BA3 ignores any data
presented by the LLC and transmits a null packet.
For a read register request the length of the LREQ bit stream is 9 bits as shown in Table 17.
Table 17. Read Register Request
BIT(s)
0
NAME
DESCRIPTION
Start bit
Indicates the beginning of the transfer (always 1)
1–3
Request type
A 100 indicating this is a read register request
4–7
Address
Identifies the address of the PHY register to be read
8
Stop bit
Indicates the end of the transfer (always 0)
For a write register request, the length of the LREQ bit stream is 17 bits as shown in Table 18.
Table 18. Write Register Request
BIT(s)
0
NAME
DESCRIPTION
Start bit
Indicates the beginning of the transfer (always 1)
1–3
Request type
A 101 indicating this is a write register request
4–7
Address
Identifies the address of the PHY register to be written to
8–15
Data
Gives the data that is to be written to the specified register address
Stop bit
Indicates the end of the transfer (always 0)
16
For an acceleration control request, the length of the LREQ data stream is 6 bits as shown in Table 19.
Table 19. Acceleration Control Request
BIT(s)
0
1–3
NAME
DESCRIPTION
Start bit
Indicates the beginning of the transfer (always 1)
Request type
A 110 indicating this is an acceleration control request
4
Control
Asynchronous period arbitration acceleration is enabled if 1, and disabled if 0
5
Stop bIt
Indicates the end of the transfer (always 0)
For fair or priority access, the LLC sends the bus request (FairReq or PriReq) at least one clock after the
PHY-LLC interface becomes idle. If the CTL terminals are asserted to the receive state (10b) by the PHY, then
any pending fair or priority request is lost (cleared). Additionally, the PHY ignores any fair or priority requests
if the receive state is asserted while the LLC is sending the request. The LLC may then reissue the request one
clock after the next interface idle.
The cycle master node uses a priority bus request (PriReq) to send a cycle start message. After receiving or
transmitting a cycle start message, the LLC can issue an isochronous bus request (IsoReq). The PHY clears
an isochronous request only when the serial bus has been won.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
37
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394a-2000 INTERFACE)
LLC service request (continued)
To send an acknowledge packet, the LLC must issue an immediate bus request (ImmReq) during the reception
of the packet addressed to it. This is required in order to minimize the idle gap between the end of the received
packet and the start of the transmitted acknowledge packet. As soon as the receive packet ends, the PHY
immediately grants control of the bus to the LLC. The LLC sends an acknowledgment to the sender unless the
header CRC of the received packet is corrupted. In this case, the LLC does not transmit an acknowledge, but
instead cancels the transmit operation and releases the interface immediately; the LLC must not use this grant
to send another type of packet. After the interface is released the LLC may proceed with another request.
The LLC may make only one bus request at a time. Once the LLC issues any request for bus access (ImmReq,
IsoReq, FairReq, or PriReq), it cannot issue another bus request until the PHY indicates that the bus request
was lost (bus arbitration lost and another packet received), or won (bus arbitration won and the LLC granted
control). The PHY ignores new bus requests while a previous bus request is pending. All bus requests are
cleared upon a bus reset.
For write register requests, the PHY loads the specified data into the addressed register as soon as the request
transfer is complete. For read register requests, the PHY returns the contents of the addressed register to the
LLC at the next opportunity through a status transfer. If a received packet interrupts the status transfer, then the
PHY continues to attempt the transfer of the requested register until it is successful. A write or read register
request may be made at any time, including while a bus request is pending. Once a read register request is
made, the PHY ignores further read register requests until the register contents are successfully transferred to
the LLC. A bus reset does not clear a pending read register request.
The TSB41BA3 includes several arbitration acceleration enhancements, which allow the PHY to improve bus
performance and throughput by reducing the number and length of interpacket gaps. These enhancements
include autonomous (fly-by) isochronous packet concatenation, autonomous fair and priority packet
concatenation onto acknowledge packets, and accelerated fair and priority request arbitration following
acknowledge packets. The enhancements are enabled when the EAA bit in PHY register 5 is set.
The arbitration acceleration enhancements may interfere with the ability of the cycle master node to transmit
the cycle start message under certain circumstances. The acceleration control request is therefore provided
to allow the LLC to temporarily enable or disable the arbitration acceleration enhancements of the TSB41BA3
during the asynchronous period. The LLC typically disables the enhancements when its internal cycle counter
rolls over indicating that a cycle start message is imminent, and then re-enables the enhancements when it
receives a cycle start message. The acceleration control request may be made at any time, however, and is
immediately serviced by the PHY. Additionally, a bus reset or isochronous bus request causes the
enhancements to be re-enabled, if the EAA bit is set.
38
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394a-2000 INTERFACE)
status transfer
A status transfer is initiated by the PHY when there is status information to be transferred to the LLC. The PHY
waits until the interface is idle before starting the transfer. The transfer is initiated by the PHY asserting status
(01b) on the CTL terminals, along with the first two bits of status information on the D[0:1] terminals. The PHY
maintains CTL = Status for the duration of the status transfer. The PHY may prematurely end a status transfer
by asserting something other than status on the CTL terminals. This occurs if a packet is received before the
status transfer completes. The PHY continues to attempt to complete the transfer until all status information has
been successfully transmitted. There is at least one idle cycle between consecutive status transfers.
The PHY normally sends just the first 4 bits of status to the LLC. These bits are status flags that are needed
by the LLC state machines. The PHY sends an entire 16-bit status packet to the LLC after a read register
request, or when the PHY has pertinent information to send to the LLC or transaction layers. The only defined
condition where the PHY automatically sends a register to the LLC is after self-ID, where the PHY sends the
physical-ID register that contains the new node address. All status transfers are either 4 or 16 bits unless
interrupted by a received packet. The status flags are considered to have been successfully transmitted to the
LLC immediately upon being sent, even if a received packet subsequently interrupts the status transfer. Register
contents are considered to have been successfully transmitted only when all 8 bits of the register have been
sent. A status transfer is retried after being interrupted only if any status flags remain to be sent, or if a register
transfer has not yet completed.
Table 20 shows the definition of the bits in the status transfer and Figure 14 shows the timing.
Table 20. Status Bits
BIT(s)
NAME
DESCRIPTION
0
Arbitration reset gap
Indicates that the PHY has detected that the bus has been idle for an arbitration reset gap time (as defined in
the IEEE 1394a-2000 standard). This bit is used by the LLC in the busy/retry state machine.
1
Subaction gap
Indicates that the PHY has detected that the bus has been idle for a subaction gap time (as defined in the
IEEE 1394a-2000 standard). This bit is used by the LLC to detect the completion of an isochronous cycle.
2
Bus reset
Indicates that the PHY has entered the bus reset state
3
Interrupt
Indicates that a PHY interrupt event has occurred. An interrupt event may be a configuration time-out, a
cable-power voltage falling too low, a state time-out, or a port status change.
4–7
Address
This field holds the address of the PHY register whose contents are being transferred to the LLC
8–15
Data
This field holds the register contents
SYSCLK
CTL0, CTL1
00
01
00
(a)
D0, D1
00
(b)
S[0:1]
S[14:15]
00
Figure 14. Status Transfer Timing
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
39
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394a-2000 INTERFACE)
status transfer (continued)
The sequence of events for a status transfer is as follows:
(a) Status transfer initiated. The PHY indicates a status transfer by asserting status on the CTL lines along with
the status data on the D0 and D1 lines (only 2 bits of status are transferred per cycle). Normally (unless
interrupted by a receive operation), a status transfer is either 2 or 8 cycles long. A 2-cycle (4-bit) transfer
occurs when only status information is to be sent. An 8-cycle (16-bit) transfer occurs when register data is
to be sent in addition to any status information.
(b) Status transfer terminated. The PHY normally terminates a status transfer by asserting idle on the CTL lines.
The PHY may also interrupt a status transfer at any cycle by asserting receive on the CTL lines to begin
a receive operation. The PHY asserts at least one idle cycle between consecutive status transfers.
receive
Whenever the PHY detects the data-prefix state on the serial bus, it initiates a receive operation by asserting
receive on the CTL terminals and a logic 1 on each of the D bus terminals (data-on indication). The PHY
indicates the start of a packet by placing the speed code (encoded as shown in Table 21) on the D terminals,
followed by packet data. The PHY holds the CTL terminals in the receive state until the last symbol of the packet
has been transferred. The PHY indicates the end of packet data by asserting idle on the CTL terminals. All
received packets are transferred to the LLC. Note that the speed code is part of the PHY-LLC protocol and is
not included in the calculation of CRC or any other data protection mechanisms.
It is possible for the PHY to receive a null packet, which consists of the data-prefix state on the serial bus followed
by the data-end state, without any packet data. A null packet is transmitted whenever the packet speed exceeds
the capability of the receiving PHY, or whenever the LLC immediately releases the bus without transmitting any
data. In this case, the PHY asserts receive on the CTL terminals with the data-on indication (all 1s) on the D
bus terminals, followed by Idle on the CTL terminals, without any speed code or data being transferred. In all
cases, in normal operation, the TSB41BA3 sends at least one data-on indication before sending the speed code
or terminating the receive operation.
The TSB41BA3 also transfers its own self-ID packet, transmitted during the self-ID phase of bus initialization,
to the LLC. This packet it transferred to the LLC just as any other received self-ID packet.
SYSCLK
CTL0, CTL1
10
(a)
D0–D7
XX
00
(b)
(e)
FF (data-on)
(c)
(d)
SPD
d0
NOTE A: SPD = Speed code, see Table 21. d0–dn = Packet data
Figure 15. Normal Packet Reception Timing
40
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
dn
00
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394a-2000 INTERFACE)
receive (continued)
The sequence of events for a normal packet reception is as follows:
(a) Receive operation initiated. The PHY indicates a receive operation by asserting receive on the CTL lines.
Normally, the interface is idle when receive is asserted. However, the receive operation may interrupt a
status transfer operation that is in progress so that the CTL lines may change from status to receive without
an intervening idle.
(b) Data-on indication. The PHY may assert the data-on indication code on the D lines for one or more cycles
preceding the speed-code.
(c) Speed-code. The PHY indicates the speed of the received packet by asserting a speed-code on the D lines
for one cycle immediately preceding packet data. The link decodes the speed-code on the first receive cycle
for which the D lines are not the data-on code. If the speed-code is invalid or indicates a speed higher that
that which the link is capable of handling, then the link must ignore the subsequent data.
(d) Receive data. Following the data-on indication (if any) and the speed-code, the PHY asserts packet data
on the D lines with receive on the CTL lines for the remainder of the receive operation.
(e) Receive operation terminated. The PHY terminates the receive operation by asserting idle on the CTL lines.
The PHY asserts at least one idle cycle following a receive operation.
SYSCLK
CTL0, CTL1
(a)
D0–D7
XX
10
00
(b)
(c)
FF (data-on)
00
Figure 16. Null Packet Reception Timing
The sequence of events for a null packet reception is as follows:
(a) Receive operation initiated. The PHY indicates a receive operation by asserting receive on the CTL lines.
Normally, the interface is idle when receive is asserted. However, the receive operation may interrupt a
status transfer operation that is in progress so that the CTL lines may change from status to receive without
an intervening idle.
(b) Data-on indication. The PHY asserts the data-on indication code on the D lines for one or more cycles.
(c) Receive operation terminated. The PHY terminates the receive operation by asserting idle on the CTL lines.
The PHY asserts at least one idle cycle following a receive operation.
Table 21. Receive Speed Codes
D0–D7
DATA RATE
00XX XXXX
S100
0100 XXXX
S200
0101 0000
S400
11YY YYYY
data-on indication
NOTE: X = Output as 0 by PHY, ignored by LLC.
Y = Output as 1 by PHY, ignored by LLC.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
41
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394a-2000 INTERFACE)
transmit
When the LLC issues a bus request through the LREQ terminal, the PHY arbitrates to gain control of the bus.
If the PHY wins arbitration for the serial bus, then the PHY-LLC interface bus is granted to the LLC by asserting
the grant state (11b) on the CTL terminals for one PCLK cycle, followed by idle for one clock cycle. The LLC
then takes control of the bus by asserting either idle (00b), hold (01b) or transmit (10b) on the CTL terminals.
Unless the LLC is immediately releasing the interface, the LLC may assert the idle state for at most one clock
before it must assert either hold or transmit on the CTL terminals. The hold state is used by the LLC to retain
control of the bus while it prepares data for transmission. The LLC may assert hold for zero or more clock cycles
(that is, the LLC need not assert hold before transmit). The PHY asserts data-prefix on the serial bus during this
time.
When the LLC is ready to send data, the LLC asserts transmit on the CTL terminals as well as sending the first
bits of packet data on the D lines. The transmit state is held on the CTL terminals until the last bits of data have
been sent. The LLC then asserts either hold or idle on the CTL terminals for one clock cycle, and then asserts
idle for one additional cycle before releasing the interface bus and putting the CTL and D terminals in a
high-impedance state. The PHY then regains control of the interface bus.
The hold state asserted at the end-of-packet transmission indicates to the PHY that the LLC requests to send
another packet (concatenated packet) without releasing the serial bus. The PHY responds to this concatenation
request by waiting the required minimum packet separation time and then asserting grant as before. This
function may be used to send a unified response after sending an acknowledge, or to send consecutive
isochronous packets during a single isochronous period. Unless multispeed concatenation is enabled, all
packets transmitted during a single bus ownership must be of the same speed (since the speed of the packet
is set before the first packet). If multispeed concatenation is enabled (when the EMSC bit of PHY register 5 is
set), then the LLC must specify the speed code of the next concatenated packet on the D terminals when it
asserts hold on the CTL terminals at the end of a packet. The encoding for this speed code is the same as the
speed code that precedes received packet data as given in Table 21.
After sending the last packet for the current bus ownership, the LLC releases the bus by asserting idle on the
CTL terminals for two clock cycles. The PHY begins asserting idle on the CTL terminals one clock after sampling
idle from the link. Note that whenever the D and CTL terminals change direction between the PHY and the LLC,
there is an extra clock period allowed so that both sides of the interface can operate on registered versions of
the interface signals.
SYSCLK
(a)
CTL0, CTL1
D0–D7
00
(b)
11
00
00
(c)
(d)
00
01
00
(e)/(f)
10
d0, d1, . . .
dn
00/01
00
00/SP
00
Link Controls CTL and D
PHY High-Impedance CTL and D Outputs
NOTE A: SPD = Speed code, see Table 21. d0–dn = Packet data
Figure 17. Normal Packet Transmission Timing
42
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
(g)
00
00
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION
transmit (continued)
The sequence of events for a normal packet transmission is as follows:
(a) Transmit operation initiated. The PHY asserts grant on the CTL lines followed by idle to hand over control
of the interface to the link so that the link may transmit a packet. The PHY releases control of the interface
(that is, it places its CTL and D outputs in a high-impedance state) following the idle cycle.
(b) Optional idle cycle. The link may assert at most one idle cycle preceding assertion of either hold or transmit.
This idle cycle is optional; the link is not required to assert idle preceding either hold or transmit.
(c) Optional hold cycles. The link may assert hold for up to 47 cycles preceding assertion of transmit. These
hold cycle(s) are optional; the link is not required to assert hold preceding transmit.
(d) Transmit data. When data is ready to be transmitted, the link asserts transmit on the CTL lines along with
the data on the D lines.
(e) Transmit operation terminated. The transmit operation is terminated by the link asserting hold or idle on the
CTL lines. The link asserts hold to indicate that the PHY is to retain control of the serial bus in order to
transmit a concatenated packet. The link asserts idle to indicate that packet transmission is complete and
the PHY may release the serial bus. The link then asserts idle for one more cycle following this hold or idle
cycle before releasing the interface and returning control to the PHY.
(f) Concatenated packet speed-code. If multispeed concatenation is enabled in the PHY, then the link asserts
a speed-code on the D lines when it asserts hold to terminate packet transmission. This speed-code
indicates the transmission speed for the concatenated packet that is to follow. The encoding for this
concatenated packet speed-code is the same as the encoding for the received packet speed-code (see
Table 21). The link may not concatenate an S100 packet onto any higher-speed packet.
(g) After regaining control of the interface, the PHY asserts at least one idle cycle before any subsequent status
transfer, receive operation, or transmit operation.
SYSCLK
(a)
CTL0, CTL1
D0–D7
00
11
(b)
00
00
00
(c)
(d)
01
(e)
00
00
00
00
Link Controls CTL and D
PHY High-Impedance CTL and D Outputs
Figure 18. Cancelled/Null Packet Transmission
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
43
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394a-2000 INTERFACE)
transmit (continued)
The sequence of events for a cancelled/null packet transmission is as follows:
(a) Transmit operation initiated. PHY asserts grant on the CTL lines followed by idle to hand over control of the
interface to the link.
(b) Optional idle cycle. The link may assert at most one idle cycle preceding assertion of hold. This idle cycle
is optional; the link is not required to assert idle preceding hold.
(c) Optional hold cycles. The link may assert hold for up to 47 cycles preceding assertion of idle. These hold
cycle(s) are optional; the link is not required to assert hold preceding idle.
(d) Null transmit termination. The null transmit operation is terminated by the link asserting two cycles of idle
on the CTL lines and then releasing the interface and returning control to the PHY. Note that the link may
assert idle for a total of three consecutive cycles if it asserts the optional first idle cycle but does not assert
hold. It is recommended that the link assert three cycles of idle to cancel a packet transmission if no hold
cycles are asserted. This ensures that either the link or PHY controls the interface in all cycles.
(e) After regaining control of the interface, the PHY asserts at least one idle cycle before any subsequent status
transfer, receive operation, or transmit operation.
interface reset and disable
The LLC controls the state of the PHY-LLC interface using the LPS signal. The interface may be placed into a
reset state, a disabled state, or be made to initialize and then return to normal operation. When the interface
is not operational (whether reset, disabled, or in the process of initialization), the PHY cancels any outstanding
bus request or register read request, and ignores any requests made via the LREQ line. Additionally, any status
information generated by the PHY is not queued and does not cause a status transfer upon restoration of the
interface to normal operation.
The LPS signal may be either a level signal or a pulsed signal, depending upon whether the PHY-LLC interface
is a direct connection or is made across an isolation barrier. When an isolation barrier exists between the PHY
and LLC the LPS signal must be pulsed. In a direct connection, the LPS signal may be either a pulsed or a level
signal. Timing parameters for the LPS signal are given in Table 22.
Table 22. LPS Timing Parameters
PARAMETER
TLPSL
TLPSH
MIN
MAX
UNIT
LPS low time (when pulsed) (see Note 5)
DESCRIPTION
0.09
2.60
µs
LPS high time (when pulsed) (see Note 5)
0.021
2.60
µs
LPS duty cycle (when pulsed) (see Note 6)
20%
60%
TLPS_RESET
TLPS_DISABLE
Time for PHY to recognize LPS deasserted and reset the interface
TRESTORE
Time to permit optional isolation circuits to restore during an interface reset
TCLK_ACTIVATE
CLK ACTIVATE
Time for PHY to recognize LPS deasserted and disable the interface
Time for PCLK to be activated from reassertion of LPS
PHY not in low-state
2.60
2.68
µs
26.03
26.11
23†
µs
60
ns
15
µs
PHY in low-power state
5.3
7.3
ms
† The maximum value for TRESTORE does not apply when the PHY-LLC interface is disabled, in which case an indefinite time may elapse before
LPS is reasserted. Otherwise, in order to reset but not disable the interface it is necessary that the LLC ensure that LPS is deasserted for less
than TLPS_DISABLE.
NOTES: 3. The specified TLPSL and TLPSH times are worst-case values appropriate for operation with the TSB41BA3. These values are broader
than those specified for the same parameters in the 1394a-2000 Supplement (that is, an implementation of LPS that meets the
requirements of 1394a-2000 operates correctly with the TSB41BA3).
4. A pulsed LPS signal must have a duty cycle (ratio of TLPSH to cycle period) in the specified range to ensure proper operation when
using an isolation barrier on the LPS signal (for example, as shown in Figure 8).
44
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394a-2000 INTERFACE)
interface reset and disable (continued)
The LLC requests that the interface be reset by deasserting the LPS signal and terminating all bus and request
activity. When the PHY observes that LPS has been deasserted for TLPS_RESET, it resets the interface. When
the interface is in the reset state, the PHY sets its CTL and D outputs in the logic 0 state and ignores any activity
on the LREQ signal. Figure 19 shows the timing for interface reset.
(a)
(c)
PCLK
CTL0, CTL1
D0 – D7
(b)
LREQ
(d)
LPS
TLPS_RESET
TRESTORE
Figure 19. Interface Reset
The sequence of events for resetting the PHY-LLC interface is as follows:
(a) Normal operation. Interface is operating normally, with LPS asserted, PCLK active, status and packet data
reception and transmission via the CTL and D lines, and request activity via the LREQ line. In the above
diagram, the LPS signal is shown as a nonpulsed level signal. However, it is permissible to use a pulsed
signal for LPS in a direct connection between the PHY and LLC; a pulsed signal is required when using an
isolation barrier.
(b) LPS deasserted. The LLC deasserts the LPS signal and, within 1.0 µs, terminates any request or interface
bus activity, places its CTL and D outputs into a high-impedance state, and drives its LREQ output low.
(c) Interface reset. After TLPS_RESET time, the PHY determines that LPS is inactive, terminates any interface
bus activity, and drives its CTL and D outputs low. The PHY-LLC interface is now in the reset state.
(d) Interface restored. After the minimum TRESTORE time, the LLC may again assert LPS active. When LPS
is asserted, the interface is initialized as described below.
If the LLC continues to keep the LPS signal deasserted, it then requests that the interface be disabled. The PHY
disables the interface when it observes that LPS has been deasserted for TLPS_DISABLE. When the interface
is disabled, the PHY sets its CTL and D outputs as stated above for interface reset, but also stops PCLK activity.
The interface is also placed into the disabled condition upon a hardware reset of the PHY. Figure 20 shows the
timing for the interface disable.
When the interface is disabled, the PHY enters a low-power state if none of its ports are active.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
45
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394a-2000 INTERFACE)
interface reset and disable (continued)
(a)
(c)
(d)
PCLK
CTL0, CTL1
D0 – D7
(b)
LREQ
LPS
TLPS_RESET
TLPS_DISABLE
Figure 20. Interface Disable
The sequence of events for disabling the PHY-LLC is as follows:
(a) Normal operation. Interface is operating normally, with LPS active, PCLK active, status and packet data
reception and transmission via the CTL and D lines, and request activity via the LREQ line.
(b) LPS deasserted. The LLC deasserts the LPS signal and, within 1.0 µs, terminates any request or interface
bus activity, places its CTL and D outputs into a high-impedance state, and drives its LREQ output low.
(c) Interface reset. After TLPS_RESET time, the PHY determines that LPS is inactive, terminates any interface
bus activity, and drives its CTL and D outputs low. The PHY-LLC interface is now in the reset state.
(d) Interface disabled. If the LPS signal remains inactive for TLPS_DISABLE time, then the PHY terminates PCLK
activity by driving the PCLK output low. The PHY-LLC interface is now in the disabled state.
After the interface has been reset, or reset and then disabled, the interface is initialized and restored to normal
operation when LPS is reasserted by the LLC. Figure 21 shows the timing for interface initialization.
46
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394a-2000 INTERFACE)
interface reset and disable (continued)
ISO
(high)
7 Cycles
SYSCLK
(b)
(c)
CTL0
(d)
CTL1
D0 – D7
LREQ
(a)
LPS
TCLK_ACTIVATE
Figure 21. Interface Initialization
The sequence of events for initialization of the PHY-LLC is as follows:
(a) LPS reasserted. After the interface has been in the reset or disabled state for at least the minimum
TRESTORE time, the LLC causes the interface to be initialized and restored to normal operation by
reasserting the LPS signal. (In the above diagram, the interface is shown in the disabled state with PCLK
low inactive. However, the interface initialization sequence described here is also executed if the interface
is merely reset but not yet disabled.)
(b) PCLK activated. If the interface is disabled, then the PHY reactivates its PCLK output when it detects that
LPS has been reasserted. If the PHY has entered a low-power state, then it takes between 5.3 to 7.3 ms
for PCLK to be restored; if the PHY is not in a low-power state, then the PCLK is restored within 60 ns. The
PCLK output is a 50% duty cycle square wave with a frequency of 49.152 MHz ±100 ppm (period of
20.345 ns). During the first 7 cycles of PCLK, the PHY continues to drive the CTL and D terminals low. The
LLC is also required to drive its CTL and D outputs low for 1 of the first 6 cycles of PCLK but to otherwise
place its CTL and D outputs in a high-impedance state. The LLC continues to drive its LREQ output low
during this time.
(c) Receive indicated. Upon the eighth PCLK cycle following reassertion of LPS, the PHY asserts the receive
state on the CTL lines and the data-on indication (all 1s) on the D lines for one or more cycles.
(d) Initialization complete. The PHY asserts the idle state on the CTL lines and logic 0 on the D lines. This
indicates that the PHY-LLC interface initialization is complete and normal operation may commence. The
PHY now accepts requests from the LLC via the LREQ line.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
47
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394B INTERFACE)
The TSB41BA3 is designed to operate with a LLC such as the Texas Instruments TSB82AA2 when the BMODE
terminal is tied high. Details of operation for the Texas Instruments LLC devices are found in the respective LLC
data sheets. The following paragraphs describe the operation of the PHY-LLC interface. This interface is
formally specified in the IEEE 1394b-2002 standard.
The interface to the LLC consists of the PCLK, LCLK_PMC, CTL0–CTL1, D0–D7, LREQ, PINT, LPS, and
S5_LKON_DS2 terminals on the TSB41BA3, as shown in Figure 22.
TSB41BA3
LCLK_PMC
PCLK
CTL0–CTL1
Link-Layer
Controller
D0–D7
LREQ
LPS
S5_LKON_DS2
PINT
Figure 22. PHY-LLC Interface
The LCLK_PMC terminal provides a clock signal to the PHY. The LLC derives this clock from the PCLK signal
and is phase-locked to the PCLK signal. All LLC to PHY transfers are synchronous to LCLK_PMC.
The PCLK terminal provides a 98.304-MHz interface system clock. All control, data, and PHY interrupt signals
are synchronized to the rising edge of PCLK.
The CTL0 and CTL1 terminals form a bidirectional control bus, which controls the flow of information and data
between the TSB41BA3 and LLC.
The D0–D7 terminals form a bidirectional data bus, which transfers status information, control information, or
packet data between the devices. The TSB41BA3 supports S400B, S200B, and S100B data transfers over the
D0–D7 data bus. In S400B, S200B, and S100B operation all Dn terminals are used.
The LREQ terminal is controlled by the LLC to send serial service requests to the PHY in order to request access
to the serial-bus for packet transmission, read or write PHY registers, or control arbitration acceleration. All data
on LREQ is synchronous to LCLK_PMC.
The LPS and S5_LKON_DS2 terminals are used for power management of the PHY and LLC. The LPS terminal
indicates the power status of the LLC, and may be used to reset the PHY-LLC interface or to disable PCLK. The
S5_LKON_DS2 terminal sends a wake-up notification to the LLC and indicates an interrupt to the LLC when
either LPS is inactive or the PHY register L bit is 0.
The PINT terminal is used by the PHY for the serial transfer of status, interrupt, and other information to the LLC.
48
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394B INTERFACE)
The TSB41BA3 normally controls the CTL0–CTL1 and D0–D7 bidirectional buses. The LLC is allowed to drive
these buses only after the LLC has been granted permission to do so by the PHY.
There are four operations that may occur on the PHY-LLC interface: link service request, status transfer, data
transmit, and data receive. The LLC issues a service request to read or write a PHY register or to request the
PHY to gain control of the serial-bus in order to transmit a packet.
The PHY may initiate a status transfer either autonomously or in response to a register read request from the
LLC.
The PHY initiates a receive operation whenever a packet is received from the serial-bus.
The PHY initiates a transmit operation after winning control of the serial-bus following a bus-request by the LLC.
The transmit operation is initiated when the PHY grants control of the interface to the LLC.
Table 23 and Table 24 show the encoding of the CTL0–CTL1 bus.
Table 23. CTL Encoding When PHY Has Control of the Bus
CTL0
CTL1
NAME
DESCRIPTION
0
0
Idle
No activity (this is the default mode)
0
1
Status
Status information is being sent from the PHY to the LLC.
1
0
Receive
An incoming packet is being sent from the PHY to the LLC.
1
1
Grant
The LLC has been given control of the bus to send an outgoing packet.
Table 24. CTL Encoding When LLC Has Control of the Bus
CTL0
CTL1
NAME
DESCRIPTION
0
0
Idle
The LLC releases the bus (transmission has been completed).
0
1
Transmit
An outgoing packet is being sent from the LLC to the PHY.
1
0
Reserved
Reserved
1
1
Hold/More
Information
The LLC is holding the bus while data is being prepared for transmission, or the LLC is sending a request to
arbitrate for access to the bus, or the LLC is identifying the end of a subaction gap to the PHY.
LLC service request
To request access to the bus, to read or write a PHY register, or to send a link notification to PHY, the LLC sends
a serial bit stream on the LREQ terminal as shown in Figure 23.
LR0
LR1
LR2
LR3
LR (n-2)
LR (n-1)
Each cell represents one clock sample time, and n is the number of bits in the request stream.
Figure 23. LREQ Request Stream
The length of the stream varies depending on the type of request as shown in Table 25.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
49
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394B INTERFACE)
LLC service request (continued)
Table 25. Request Stream Bit Length
REQUEST TYPE
NUMBER OF BITS
Bus request
11
Read register request
10
Write register request
18
Link notification request
6
PHY-link interface reset request
6
Regardless of the type of request, a start bit of 1 is required at the beginning of the stream, and a stop bit of 0
is required at the end of the stream. The second through fifth bits of the request stream indicate the type of the
request. In the descriptions below, bit 0 is the most significant and is transmitted first in the request bit stream.
The LREQ terminal is normally low.
Table 26 shows the encoding for the request type.
Table 26. Request Type Encoding
LR1–LR4
NAME
DESCRIPTION
0000
Reserved
Reserved
0001
Immed_Req
Immediate request. Upon detection of idle, the PHY arbitrates for the bus.
0010
Next_Even
Next even request. The PHY arbitrates for the bus to send an asynchronous packet in the even fairness
interval phase.
0011
Next_Odd
Next odd request. The PHY arbitrates for the bus to send an asynchronous packet in the odd fairness
interval phase.
0100
Current
Current request. The PHY arbitrates for the bus to send an asynchronous packet in the current fairness
interval.
0101
Reserved
Reserved
0110
Isoch_Req_Even
Isochronous even request. The PHY arbitrates for the bus to send an isochronous packet in the even
isochronous period.
0111
Isoch_Req_Odd
Isochronous odd request. The PHY arbitrates for the bus to send an isochronous packet in the odd
isochronous period.
1000
Cyc_Start_Req
Cycle start request. The PHY arbitrates for the bus to send a cycle start packet.
1001
Reserved
Reserved
1010
Reg_Read
Register read request. The PHY returns the specified register contents through a status transfer.
1011
Reg_Write
Register write request. Write to the specified register in the PHY.
1100
Isoch_Phase_Even
Isochronous phase even notification. The link reports to the PHY that:
1) A cycle start packet has been received
2) The link has set the isochronous phase to even.
1101
Isoch_Phase_Odd
Isochronous phase odd notification. The link reports to the PHY that:
1) A cycle start packet has been received
2) The link has set the isochronous phase to odd.
1110
Cycle_Start_Due
Cycle start due notification. The link reports to the PHY that a cycle start packet is due for reception.
1111
Reserved
Reserved
For a bus request, the length of the LREQ bit stream is 11 bits as shown in Table 27.
50
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394B INTERFACE)
LLC service request (continued)
Table 27. Bus Request
BIT(s)
0
NAME
DESCRIPTION
Start bit
Indicates the beginning of the transfer (always 1)
Request type
Indicates the type of bus request. See Table 26.
5
Request format
Indicates the packet format to be used for packet transmission. See Table 28.
6–9
Request speed
Indicates the speed at which the link sends the data to the PHY. See Table 29 for the encoding of this field.
10
Stop bit
Indicates the end of the transfer (always 0). If bit 6 is 0, then this bit may be omitted.
1–4
Table 28 shows the 1-bit request format field used in bus requests.
Table 28. Bus Request Format Encoding
LR5
DATA RATE
0
Link does not request either beta or legacy packet format for bus transmission
1
Link requests beta packet format for bus transmission
Table 29 shows the 4-bit request speed field used in bus requests.
Table 29. TBus Request Speed Encoding
LR6–LR9
DATA RATE
0000
S100
0001
Reserved
0010
S200
0011
Reserved
0100
S400
0101
Reserved
0110
S800
All Others
Invalid
NOTE:
The TSB41BA3 accepts a bus request with an invalid speed code and processes the bus request
normally. However, during packet transmission for such a request, the TSB41BA3 ignores any data
presented by the LLC and transmits a null packet.
For a read register request, the length of the LREQ bit stream is 10 bits as shown in Table 30.
Table 30. Read Register Request
BIT(s)
0
NAME
DESCRIPTION
Start bit
Indicates the beginning of the transfer (always 1)
1–4
Request type
A 1010 indicates this is a read register request
5–8
Address
Identifies the address of the PHY register to be read
9
Stop bit
Indicates the end of the transfer (always 0)
For a write register request, the length of the LREQ bit stream is 18 bits as shown in Table 31.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
51
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394B INTERFACE)
LLC service request (continued)
Table 31. Write Register Request
BIT(s)
0
NAME
DESCRIPTION
Start bit
Indicates the beginning of the transfer (always 1)
1–4
Request type
A 1011 indicates this is a write register request
5–8
Address
Identifies the address of the PHY register to be written
9–16
Data
Gives the data that is to be written to the specified register address
Stop bit
Indicates the end of the transfer (always 0)
17
For a link notification request, the length of the LREQ bit stream is 6 bits as shown in Table 32.
Table 32. Link Notification Request
BIT(s)
0
1–4
5
NAME
DESCRIPTION
Start bit
Indicates the beginning of the transfer (always 1)
Request type
A 1100, 1101, or 1110 indicates this is a link notification request
Stop bit
Indicates the end of the transfer (always 0)
For fair or priority access, the LLC sends a bus request at least one clock after the PHY-LLC interface becomes
idle. The PHY queues all bus requests and can queue one request of each type. If the LLC issues a different
request of the same type, then the new request overwrites any nonserviced request of that type. Note, upon
the receipt (CTL terminals are asserted to the receive state, 10b) of a packet, queued requests are not cleared
by the PHY.
The cycle master node uses a cycle start request (Cyc_Start_Req) to send a cycle start message. After
receiving or transmitting a cycle start message, the LLC can issue an isochronous bus request (IsoReq). The
PHY clears an isochronous request only when the serial bus has been won.
To send an acknowledge packet, the LLC must issue an immediate bus request (Immed_Req) during the
reception of the packet addressed to it. This is required in order to minimize the idle gap between the end of
the received packet and the start of the transmitted acknowledge packet. As soon as the received packet ends,
the PHY immediately grants control of the bus to the LLC. The LLC sends an acknowledgment to the sender
unless the header CRC of the received packet is corrupted. In this case, the LLC does not transmit an
acknowledge, but instead cancels the transmit operation and releases the interface immediately; the LLC must
not use this grant to send another type of packet. After the interface is released the LLC may proceed with
another request.
For write register requests, the PHY loads the specified data into the addressed register as soon as the request
transfer is complete. For read register requests, the PHY returns the contents of the addressed register to the
LLC at the next opportunity through a PHY status transfer. A write or read register request may be made at any
time, including while a bus request is pending. Once a read register request is made, the PHY ignores further
read register requests until the register contents are successfully transferred to the LLC. A bus reset does not
clear a pending read register request.
52
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394B INTERFACE)
status transfer
A status transfer is initiated by the PHY when there is status information to be transferred to the LLC. Two types
of status transfers may occur: bus status transfer and PHY status transfer. Bus status transfers send the
following status information: bus reset indications, subaction and arbitration reset gap indications, cycle start
indications, and PHY interface reset indications. PHY status transfers send the following information: PHY
interrupt indications, unsolicited and solicited PHY register data, bus initialization indications, and PHY-link
interface error indications. The PHY uses a different mechanism to send the bus status transfer and the PHY
status transfer.
Bus status transfers use the CTL0–CTL1 and D0–D7 terminals to transfer status information. Bus status transfers can occur during idle periods on the PHY-link interface or during packet reception. When the status transfer
occurs, a single PCLK cycle of status information is sent to the LLC. The information is sent such that each individual Dn terminal conveys a different bus status transfer event. During any bus status transfer, only one status
bit is set. If the PHY-link interface is inactive, then the status information is not sent. When a bus reset on the
serial bus occurs, the PHY sends a bus reset indication (via the CTLn and Dn terminals), cancels all packet
transfer requests, sets asynchronous and isochronous phases to even, forwards self-ID packets to the link, and
sends an unsolicited PHY register 0 status transfer (via the PINT terminal) to the LLC. In the case of a PHY
interface reset operation, the PHY-link interface is reset on the following PCLK cycle.
Table 33 shows the definition of the bits during the bus status transfer and Figure 24 shows the timing.
Table 33. Status Bits
STATUS BIT
DESCRIPTION
D0
Bus reset
D1
Arbitration reset gap—Odd
D2
Arbitration reset gap—Even
D3
Cycle start—Odd
D4
Cycle start—Even
D5
Subaction gap
D6
PHY interface reset
D7
Reserved
CTL[0:1]
XX
01
XX
D[0:7]
XX
ST
XX
Status Bits
Figure 24. Bus Status Transfer Timing
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
53
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394B INTERFACE)
status transfer (continued)
PHY status transfers use the PINT terminal to serially send status information to the LLC as shown in Figure 25.
PHY status transfers (Table 34) can occur at any time during normal operation. The PHY uses the
PHY_INTERRUPT PHY status transfer when required to interrupt the LLC due to a configuration timeout, a
cable power failure, a port interrupt, or an arbitration timeout. When transferring PHY register contents, the PHY
uses either the solicited or the unsolicited register read status transfer. The unsolicited register 0 contents are
passed to the LLC only during initialization of the serial bus. After any PHY-link interface initialization, the PHY
sends a PHY status transfer indicating whether or not a bus reset occurred during the inactive period of the
PHY-link interface. If the PHY receives an illegal request from the LLC, then the PHY issues an
INTERFACE_ERROR PHY status transfer.
LR0
LR1
LR2
LR3
LR (n-2)
LR (n-1)
Each cell represents one clock sample time, and n is the number of bits in the request stream.
Figure 25. PINT (PHY Interrupt) Stream
Table 34. PHY Status Transfer Encoding
PI[1:3]
NAME
DESCRIPTION
NUMBER OF BITS
000
NOP
No status indication
5
001
PHY_INTERRUPT
Interrupt indication: configuration timeout, cable power failure, port event
interrupt, or arbitration state machine timeout
5
010
PHY_REGISTER_SOL
Solicited PHY register read
17
011
PHY_REGISTER_UNSOL
Unsolicited PHY register read
17
100
PH_RESTORE_NO_RESET
PHY-link interface initialized; no bus resets occurred
5
101
PH_RESTORE_RESET
PHY-link interface initialized; a bus reset occurred
5
110
INTERFACE_ERROR
PHY received illegal request
111
Reserved
Reserved
5
Reserved
Most PHY status transfers are 5 bits long. The transfer consists of a start bit (always 1), followed by a request
type (see Table 34), and lastly followed by a stop bit (always 0). The only exception is when the transfer of a
register contents occurs. Solicited and unsolicited PHY register read transfers are 17 bits long and include the
additional information of the register address and the data contents of the register (see Table 35).
Table 35. Register Read (Solicited and Unsolicited) PHY Status Transfer Encoding
BIT(s)
0
DESCRIPTION
Indicates the beginning of the transfer (always 1)
1–3
Request type
A 010 or a 011 indicates a solicited or unsolicited register contents transfer
4–7
Address
Identifies the address of the PHY register whose contents are being transferred
8–15
Data
The contents of the register specified in bits 4 through 7
Stop bit
Indicates the end of the transfer (always 0)
16
54
NAME
Start bit
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394B INTERFACE)
receive
When the PHY detects the data-prefix state on the serial bus, it initiates a receive operation by asserting receive
on the CTL terminals and a logic 1 on each of the D terminals (data-on indication). The PHY indicates the start
of a packet by placing the speed code (encoded as shown in Table 36) on the D terminals, followed by packet
data. The PHY holds the CTL terminals in the receive state until the last symbol of the packet has been
transferred. The PHY indicates the end of packet data by asserting idle on the CTL terminals. All received
packets are transferred to the LLC. Note that the speed code is part of the PHY-LLC protocol and is not included
in the calculation of CRC or any other data protection mechanisms.
The PHY may optionally send status information to the LLC at anytime during the data-on indication. Only bus
status transfer information can be sent during a data-on indication. The PHY holds the CTL terminals in the
status state for 1 PCLK cycle and modifies the D terminals to the correct status state. Note that the status transfer
during the data-on indication does not need to be preceded or followed by a data-on indication.
It is possible for the PHY to receive a null packet, which consists of the data-prefix state on the serial bus followed
by the data-end state, without any packet data. A null packet is transmitted whenever the packet speed exceeds
the capability of the receiving PHY, or whenever the LLC immediately releases the bus without transmitting any
data. In this case, the PHY asserts receive on the CTL terminals with the data-on indication (all 1s) on the D
terminals, followed by Idle on the CTL terminals, without any speed code or data being transferred. In all cases,
in normal operation, the TSB41BA3 sends at least one data-on indication before sending the speed code or
terminating the receive operation.
The TSB41BA3 also transfers its own self-ID packet, transmitted during the self-ID phase of bus initialization,
to the LLC. This packet it transferred to the LLC just as any other received self-ID packet.
PCLK
CTL0, CTL1
10
(a)
D0–D7
XX
00
(e)
(b)
FF (data-on)
(c)
(d)
SPD
d0
dn
00
NOTE A: SPD = Speed code, see Table 36. d0–dn = Packet data
Figure 26. Normal Packet Reception Timing
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
55
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394B INTERFACE)
receive (continued)
PCLK
CTL0, CTL1
10
01
(b)
(a)
D0–D7
XX
00
10
(e)
FF (data-on)
STATUS
FF
(data-on)
(c)
(d)
SPD
d0
dn
00
NOTE A: SPD = Speed code, see Table 36. d0–dn = Packet data. STATUS = status bits, see Table 33.
Figure 27. Normal Packet Reception Timing With Optional Bus Status Transfer
The sequence of events for a normal packet reception is as follows:
(a) Receive operation initiated. The PHY indicates a receive operation by asserting receive on the CTL lines.
Normally, the interface is idle when receive is asserted. However, the receive operation may interrupt a
status transfer operation that is in progress so that the CTL lines may change from status to receive without
an intervening idle.
(b) Data-on indication. The PHY may assert the data-on indication code on the D lines for one or more cycles
preceding the speed-code. The PHY may optionally send a bus status transfer during the data-on indication
for one PCLK cycle. During this cycle, the PHY asserts status (01b) on the CTL lines while sending status
information on the D lines.
(c) Speed-code. The PHY indicates the speed of the received packet by asserting a speed-code on the D lines
for one cycle immediately preceding packet data. The link decodes the speed-code on the first receive cycle
for which the D lines are not the data-on code. If the speed-code is invalid or indicates a speed higher that
that which the link is capable of handling, then the link must ignore the subsequent data.
(d) Receive data. Following the data-on indication (if any) and the speed-code, the PHY asserts packet data
on the D lines with receive on the CTL lines for the remainder of the receive operation.
(e) Receive operation terminated. The PHY terminates the receive operation by asserting idle on the CTL lines.
The PHY asserts at least one idle cycle following a receive operation.
PCLK
CTL0, CTL1
(a)
D0–D7
XX
10
00
(b)
(c)
FF (data-on)
Figure 28. Null Packet Reception Timing
56
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
00
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394B INTERFACE)
receive (continued)
The sequence of events for a null packet reception is as follows:
(a) Receive operation initiated. The PHY indicates a receive operation by asserting receive on the CTL lines.
Normally, the interface is idle when receive is asserted. However, the receive operation may interrupt a
status transfer operation that is in progress so that the CTL lines may change from status to receive without
an intervening idle.
(b) Data-on indication. The PHY asserts the data-on indication code on the D lines for one or more cycles.
(c) Receive operation terminated. The PHY terminates the receive operation by asserting idle on the CTL lines.
The PHY asserts at least one idle cycle following a receive operation.
Table 36. Receive Speed Codes and Format
D0–D7
DATA RATE AND FORMAT
0000 0000
S100 legacy
0000 0001
S100 beta
0000 0100
S200 legacy
0000 0101
S200 beta
0000 1000
S400 legacy
0000 1001
S400 beta
0000 1101
S800 beta
1111 1111
Data-on indication
All Others
Reserved
NOTE: Y = Output as 1 by PHY, ignored by LLC.
X = Output as 0 by PHY, ignored by LLC.
transmit
When the LLC issues a bus request through the LREQ terminal, the PHY arbitrates to gain control of the bus.
If the PHY wins arbitration for the serial bus, then the PHY-LLC interface bus is granted to the LLC by asserting
the grant state (11b) on the CTL terminals and the grant type on the D terminals for one PCLK cycle, followed
by idle for one clock cycle. The LLC then takes control of the bus by asserting either idle (00b), hold (11b) or
transmit (01b) on the CTL terminals. If the PHY does not detect a hold or transmit state within eight PCLK cycles,
then the PHY takes control of the PHY-link interface. The hold state is used by the LLC to retain control of the
bus while it prepares data for transmission. The LLC may assert hold for zero or more clock cycles (that is, the
LLC need not assert hold before transmit). During the hold state, the LLC is expected to drive the D lines to 0.
The PHY asserts data-prefix on the serial bus during this time.
When the LLC is ready to send data, the LLC asserts transmit on the CTL terminals as well as sending the first
bits of packet data on the D lines. The transmit state is held on the CTL terminals until the last bits of data have
been sent. The LLC then asserts either hold or idle on the CTL terminals for one clock cycle. If the hold is
asserted, then the hold is immediately followed by one clock cycle of idle. The link then releases the PHY-link
interface by putting the CTL and D terminals in a high-impedance state. The PHY then regains control of the
PHY-link interface.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
57
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394B INTERFACE)
transmit (continued)
PHY CTL[0:1]
00
11
00
ZZ
ZZ
ZZ
ZZ
ZZ
ZZ
PHY D[0:7]
00
GT
00
ZZ
ZZ
ZZ
ZZ
ZZ
ZZ
LLC CTL[0:1]
ZZ
ZZ
ZZ
ZZ
ZZ
11
11
01
01
LLC D[0:7]
ZZ
ZZ
ZZ
ZZ
ZZ
00
00
d0
d1
PHY CTL[0:1]
ZZ
ZZ
ZZ
ZZ
ZZ
ZZ
00
00
00
PHY D[0:7]
ZZ
ZZ
ZZ
ZZ
ZZ
ZZ
00
00
00
LLC CTL[0:1]
LLC D[0:7]
GT = Grant Type
01
01
11
00
ZZ
ZZ
ZZ
ZZ
ZZ
dn–1
dn
LR
00
ZZ
ZZ
ZZ
ZZ
ZZ
LR = Link Request Type
d0–dn = packet data
Figure 29. Transmit Packet Timing With Optional Link Request
The hold state asserted at the end of packet transmission allows the LLC to make an additional link request for
packet transmission and/or to notify the PHY that the packet marks the end of a subaction. The link requests
allowed after packet transmission are listed in Table 37 (note that the link request types allowed during this
period are a subset of all of the allowed types of link requests—see Table 26). The associated speed codes and
packet format are listed in Table 37 and Table 38, respectively. If the LLC requests to send an additional packet,
then the PHY does not necessarily have to grant the request. If the LLC is notifying the PHY of the end of a
subaction, then the LLC sets D4 during the hold state at the end of packet transmission.
58
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394B INTERFACE)
transmit (continued)
Table 37. Link Request Type Encoding During Packet Transmission
D1–D3
Request Type
000
No request
001
Isoch_Req_Odd
010
Isoch_Req_Even
011
Current
100
Next_Even
101
Next_Odd
110
Cyc_Start_Req
111
Reserved
Table 38. Link Request Speed Code Encoding During Packet Transmission
D5–D6
DATA RATE
00
S100
01
S200
10
S400
11
S800
Table 39. Link Request Format Encoding During Packet Transmission
D0
FORMAT
0
Link does not request either beta or legacy packet format for bus transmission
1
Link requests beta packet format for bus transmission
Table 40. Subaction End Notification Encoding During Packet Transmission
D4
DESCRIPTION
0
Transmitted packet does not represent end of a subaction
1
Transmitted packet marks the end of a subaction
The PHY indicates to the link during the GRANT cycle which type of grant is being issued. This indication
includes the grant type as well as the grant speed. The link uses the bus grant for transmitting the granted packet
type. The link transmits a granted packet type only if its request type exactly matches the granted speed and
the granted format.
Table 41. Format Type During Grant Cycle
D0 VALUE DURING GRANT
CYCLE
FORMAT
0
Unspecified
1
Beta format
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
59
TSB41BA3-EP
IEEE 1394b THREE-PORT CABLE TRANSCEIVER/ARBITER
SGLS173 – JUNE 2003
PRINCIPLES OF OPERATION (1394B INTERFACE)
transmit (continued)
Table 42. Grant Type Values During Grant Cycle
[D1–D3] VALUE DURING
GRANT CYCLE
REQUEST TYPE
000
Reserved
001
Reserved
010
Isochronous grant
011
Reserved
100
Reserved
101
Asynchronous grant
110
Cycle start grant
111
Immediate grant
Table 43. Speed Type Values During Grant Cycle
60
[D5–D6] VALUE DURING
GRANT CYCLE
SPEED TYPE
00
S100
01
S200
10
S400
11
S800
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
MECHANICAL DATA
MPQF049 – JANUARY 1998
PFP (S-PQFP-G80)
PowerPAD PLASTIC QUAD FLATPACK
0,27
0,17
0,50
60
0,08 M
41
40
61
Thermal Pad
(see Note D)
80
21
1
0,13 NOM
20
Gage Plane
9,50 TYP
12,20
SQ
11,80
0,25
0,15
0,05
14,20
SQ
13,80
0°– 7°
0,75
0,45
1,05
0,95
Seating Plane
0,08
1,20 MAX
4146925/A 01/98
NOTES: A.
B.
C.
D.
All linear dimensions are in millimeters.
This drawing is subject to change without notice.
Body dimensions do not include mold flash or protrusion.
The package thermal performance may be enhanced by bonding the thermal pad to an external thermal plane.
This pad is electrically and thermally connected to the backside of the die and possibly selected leads.
E. Falls within JEDEC MS-026
PowerPAD is a trademark of Texas Instruments Incorporated.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications,
enhancements, improvements, and other changes to its products and services at any time and to discontinue
any product or service without notice. Customers should obtain the latest relevant information before placing
orders and should verify that such information is current and complete. All products are sold subject to TI’s terms
and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI
deems necessary to support this warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for
their products and applications using TI components. To minimize the risks associated with customer products
and applications, customers should provide adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right,
copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process
in which TI products or services are used. Information published by TI regarding third-party products or services
does not constitute a license from TI to use such products or services or a warranty or endorsement thereof.
Use of such information may require a license from a third party under the patents or other intellectual property
of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of information in TI data books or data sheets is permissible only if reproduction is without
alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction
of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for
such altered documentation.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that
product or service voids all express and any implied warranties for the associated TI product or service and
is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.
Following are URLs where you can obtain information on other Texas Instruments products and application
solutions:
Products
Amplifiers
Applications
amplifier.ti.com
Audio
www.ti.com/audio
Data Converters
dataconverter.ti.com
Automotive
www.ti.com/automotive
DSP
dsp.ti.com
Broadband
www.ti.com/broadband
Interface
interface.ti.com
Digital Control
www.ti.com/digitalcontrol
Logic
logic.ti.com
Military
www.ti.com/military
Power Mgmt
power.ti.com
Optical Networking
www.ti.com/opticalnetwork
Microcontrollers
microcontroller.ti.com
Security
www.ti.com/security
Telephony
www.ti.com/telephony
Video & Imaging
www.ti.com/video
Wireless
www.ti.com/wireless
Mailing Address:
Texas Instruments
Post Office Box 655303 Dallas, Texas 75265
Copyright  2003, Texas Instruments Incorporated