ETC 1550-0197

9HUVD

Coaxial Test Cables
2102 Series
V2.0
Features
• Operation to 18 GHz
• Field Interchangable Connectors
SMA, Type N, ETNC, 7mm
• Electrically Stable With Flexure
• Triple Shielded, Low Loss Cable
• Abrasion Resistant Nomex Jacket
• Armored Jacket Option
Description
9HUVD/,1( cables
allow the user to interchange
coaxial connectors with alternate interface
styles or to replace worn or damaged
connectors without compromising performance.
cables make use of M/A-COM’s
legendary, field proven cable construction and
connector attachment methods to maximize
cable service life, increase productivity, reduce
down-time and insure trouble-free operation in a
variety of harsh conditions.
9HUVD/,1( 9HUVD/,1(
cables remain unequaled for
versatility, reliability, ruggedness and long
service life when year in / year out RF and
microwave testing is required.
Applications
•
•
•
•
•
High Volume Test Lab and Manufacturing Line Test Operations
Field and Job Site Installation, Verification and Test Activities
Periodic and Quality Program Tests
Upgrade and Replacement of RF Test Equipment Test Port Cables
Test Applications Requiring Cables With Ruggedness, Long Life and Consistent Performance
M/A-COM Inc.
North America:
Tel. (800) 366-2266
Fax (800) 618-8883
Š
Asia / Pacific:
Tel. +85 2 2111 8088
Fax +85 2 2111 8087
Š
Europe:
Tel. +44 (1344) 869-595
Fax +44 (1344) 300-020
9H UVD

Coaxial Test Cables
Specifications
Operating Frequency, Maximum
VSWR, Maximum
18GHz
1.35:1
Phase Stability
Min. Bend Radius (Nomex
±0.5°/GHz
1.0 in (25.4 mm)
Jacket)
Shielding Effectiveness
Propagation Velocity (% speed of light)
>100 dB
76%
Operating Temperature Range
Flex Life
-55 to 125°C
100,000 min
Specifications Subject to Change Without Notice
Typical Performance Data
Maximum Cable Assembly Insertion Loss
5
Insertion Loss dB
4.5
3.0 meter
4
3.5
3
2.0 meter
2.5
1.5 meter
2
1.5
1.0 meter
1
0.5 meter
0.5
0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Frequency GHz
Connector Dimensions
SMA Male
4.4 (112.1)
ETNC
4.4 (112.7)
.65 (16.5)
MAX
.58 (14.7) MAX
.50 (12.7) HEX
.562 (14.3) HEX
Type N Male
7mm
4.9 (124.5)
4.50 (113.0)
.863 (21.92)
MAX
.87 (22.1)
MAX
.750 (19.1) HEX
How To Order
005
010
015
020
030
Length
0.5 meter
1.0 meter
1.5 meter
2.0 meter
3.0 meter
End 1
Jacket Options
N Nomex
A Armored *
End 2
* 2.0m and 3.0m
length only
2102-XXXX-XXXX
Connector Options
01 ETNC Male
02 Type N Male
03 SMA Male
04 7mm
(Lowest Number First)
Replacable Interface Part Numbers
ETNC Male
1550-0229
Type N Male
1550-0249
SMA Male
1550-0197
7mm
1550-0246
Consult Distributor For Part Numbers Currently In Stock
M/A-COM Inc.
North America:
Tel. (800) 366-2266
Fax (800) 618-8883
Š
Asia / Pacific:
Tel. +85 2 2111 8088
Fax +85 2 2111 8087
Š
Europe:
Tel. +44 (1344) 869-595
Fax +44 (1344) 300-020