ETC 6057

3
Half and Full Facepiece
Respirators 6000 Series
4017
page 1 of 4
Issue Date 06/01/00
Unmatched performance
and comfort
3M™ Respirators 6000 Series
provide low-maintenance and
offer the user comfort and
convenience coupled with the cost
savings of a reusable respirator.
Features/Benefits
• Used with 3M™ Filters and
Cartridges, these respirators are
among the lightest available.
• The swept back design of the
cartridges improves balance
and visibility.
• 6000 series facepieces cost
about half as much as typical
reusable respirators.
• Remarkably comfortable,
soft, lightweight facepiece
and easy-to-adjust head straps.
• Reusable. Just dispose of the
cartridges/filters when used
to capacity.
• Can be disassembled, cleaned
and reused.
• NIOSH approved for negative
pressure air purifying and
positive pressure dual airline
applications.
• Supplied with reclosable
storage bag.
• The half and full facepieces are
each available in 3 sizes (small,
medium, large) to comfortably
fit many faces.
The 6000 Series respirators
can be used in dual airline mode:
• Available with both backmounted and front-mounted
breathing tubes.
3
3
3
The 3M™ Half and Full Facepiece Respirators 6000 Series with
replaceable cartridges/filters provide outstanding comfort, versatility
and reliability.
• Systems can be used in
combination with NIOSH
approved 3M™ 2000 Series
Filters or 3M™ 6000 Series
Cartridges and P100
Filter/Cartridges.
• Cartridge/filter connections
provide negative and positive
pressure capability in one
respirator assembly.
• Can be used on both high and
low pressure systems.
• Wearer can disconnect the airline
at the air regulating valve and
the system is changed to a
filters/cartridges air purifying
mode—then back to supplied air
system with a simple
reconnection of the airline.
• Small diameter breathing tubes
are simple to work with and easy
to clean and decontaminate.
! WARNING
These respirators help reduce
exposure to certain airborne
contaminants. Misuse may
result in sickness or death.
Before use, the wearer must read
and understand User
Instructions provided as a part
of product packaging. Time use
limitations may apply. For proper
use, see supervisor, packaging
or call 3M OH&ESD Technical
Service, call 1-800-243-4630.
In Canada, call 1-519-452-6137
or 1-800-265-1840, ext. 6137.
3M™ Half and Full Facepiece Respirators
6000 Series (continued)
4017
page 2 of 4
Half Facepieces
Full Facepieces
6100 Half Facepiece
(Small)
6200 Half Facepiece
(Medium)
6300 Half Facepiece
(Large)
6700 Full Facepiece
(Small)
6800 Full Facepiece
(Medium)
6900 Full Facepiece
(Large)
2000 Series, 7093, 5N11, 5P71 Filters and Accessories
7
6
1
3
209
20 7 8
3
HF
3
209
3
2 076
1
3
2091
P100 Filter
11J6200
NIOSH
20 9
2078
P95 Filter with
nuisance level
organic vapor and
acid gas relief*
11J6200
NIOSH
2096
P100 Filter
with nuisance level
acid gas relief*
3
11J6200
NIOSH
20 9
3P100
209
3P100
209
3P100
7
3
2076HF
P95 Filter with
hydrogen fluoride,
nuisance level
acid gas relief*
207
2071
P95 Filter
11J6200
NIOSH
6
P95
HYDROGEN FLUORIDE
00J0000
NIOSH
11J6200
NIOSH
1
1
20 7 8
3 P95
2 076
HF
207
3 P95
2097
P100 Filter
with nuisance level
organic vapor
relief*
*Nuisance levels refer to concentrations below the OSHA PEL.
3
NO.
PART 1
50
3
NO.
PART 2
50
DO
NO
FRO
NIN G: QU
IVE FIT T
TAT
3
3M™ Fit Test Respirator
3M developed this product
specifically for quantitative fit
testing. Available in small (6100Q),
medium (6200Q) and large
(6300Q). A probe has been added
for fit testing purposes. Do not use
for respiratory protection.
501
Filter Retainer
(Use with the 5N11
and 5P71 Filters)
OVE
TRID
GE
502
Filter Adapter
(Use with the 2000
Series and 7093 Filters)
3M™ Fit Test Kits
• FT-10 Qualitative Fit Test
Apparatus (sweet solution)
• FT-20 Training and Fit Testing
Case (sweet solution)
• FT-30 Qualitative Fit Test
Apparatus (bitter solution)
S PIRATO R
.
AR
5P71
P95 Filter
(Use with the 501
Filter Retainer)
T RE
W
TI
5N11
N95 Filter
(Use with the 501
Filter Retainer)
ES
AN
7093
P100 Filter
EM
TR
AR
MC
3M™ Quantitative Fit Test
Adapter 601
(for use with all 3M bayonet
attachment facepieces)
3M™ Half and Full Facepiece Respirators
6000 Series (continued)
4017
page 3 of 4
NIOSH Approval*
Product
Number
NIOSH Approval*
6001
Certain organic vapors (a)(b)
60921
P100/Certain organic vapors (a)(b)
6002
Chlorine, hydrogen chloride, and
sulfur dioxide or chlorine dioxide or
hydrogen sulfide (escape only) (a)(b)
60922
6003
Certain organic vapors, chlorine,
hydrogen chloride, and sulfur
dioxide or hydrogen sulfide
(escape only) or hydrogen
fluoride (a)(b)
P100/Chlorine, hydrogen chloride,
and sulfur dioxide or chlorine
dioxide or hydrogen sulfide
(escape only) (a)(b)
60923
P100/Certain organic vapors, chlorine,
hydrogen chloride, and sulfur dioxide
or hydrogen sulfide (escape only) or
hydrogen fluoride (a)(b)
Product
Number
6004
Ammonia and methylamine (a)(b)
60924
6005
Formaldehyde and certain organic
vapors (a)(b)(c)
P100/Ammonia and methylamine
(a)(b)
60925
P100/Formaldehyde and certain
organic vapors (a)(b)
60926
P100/Certain organic vapors,
chlorine, hydrogen chloride,
chlorine dioxide, sulfur dioxide,
hydrogen sulfide (escape only)
ammonia/methylamine,
formaldehyde or hydrogen
fluoride (a)(b)(c)
60929
P100/Mercury vapor or chlorine
gas (a)(b)
6006
6009
Certain organic vapors, chlorine,
hydrogen chloride, chlorine dioxide,
sulfur dioxide, hydrogen sulfide
(escape only) ammonia/methylamine,
formaldehyde or hydrogen fluoride
(a)(b)(c)
Mercury vapor or chlorine gas
* For respiratory protection against the following contaminants up to 10X PEL with half facepiece respirators or 50X PEL
with full facepiece respirators.
(a) All respirators and respirator/filter assemblies can be used up to the NIOSH approval limits, 10X PEL for half facepiece
respirators or 50X PEL for full facepiece respirators or the maximum use concentration allowable in applicable OSHA
standards, whichever is lower.
(b) For specific usage, limitations and warning information, see respirator and/or filter packaging, or call 3M OH&ESD
Technical Service 1-800-243-4630. In Canada call 1-800-265-1840.
(c) OSHA regulations require that gas-proof goggles be worn with half facepiece respirators when used against
formaldehyde.
Full Facepiece Replacement Parts
and Accessories 6000 Series
6000 Half Facepiece
Replacement Parts
Accessories
7883
6889
6892
6893
6894
6895
6896
6897
6898
6899
6878
6885
6886
Neck Strap Assembly
Exhalation Valve
Center Adapter Assembly
Inhalation Valve
Nose Cup Assembly
Inhalation Gasket
Center Adapter Gasket
Head Harness Assembly
Lens Assembly
Lens Frame Kit
Spectacle Kit
Face Shield Cover
Tinted Lens Cover
Half Facepiece Replacement Parts 6000 Series
Replacement Parts
6281
6889
6893
6895
Respirator Strap Assembly
Exhalation Valve
Inhalation Valve
Inhalation Gasket
Facepieces
per bag
Facepieces
per case
1
24
6000 Full Facepiece
Facepieces
per box
Facepieces
per case
1
4
3M™ Half and Full Facepiece Respirators
6000 Series (continued)
4017
page 4 of 4
To complete a 3M™ Dual Airline Respirator System, select a facepiece, an adapter kit and an air supply hose.
For example: 6800 + SA-2000 + W-9435-100 = complete system.
High
Pressure
Low
Pressure
Standard Back-Mounted Adapter Kit. Includes SA-2500 Breathing Tube, GVP-127
Belt and SA-1009 Air Regulator or SA-1029 Connector (low pressure)
SA-2000
SA-2000LP
Combination Back-Mounted Adapter Kit. Includes 2600 Breathing Tube, GVP-127 Belt
and SA-1009 Regulator or SA-1029 Connector (low pressure). Cartridges/Filters not included.
SA-2100
SA-2100LP
Standard Front-Mounted Adapter Kit. Includes SA-1500 Breathing Tube, GVP-127 Belt,
and SA-1009 Regulator or SA-1029 Connector (Low pressure)
SA-1000
SA-1000LP
Combination Front-Mounted Adapter Kit. Includes SA-1600 Breathing Tube, GVP-127 Belt,
and SA-1009 Regulator or SA-1029 Connector (low pressure). Cartridges/Filters not included.
SA-1100
SA-1100LP
Accessories and replacement parts
Note: For more information on 3M™ Dual Airline Supplied Air Systems, please call 3M’s Fax On Demand line at 1-800-646-1655
and order document number 4024.
Refer to Fax On Demand
document number 9011 for
National Stock Numbers.
! IMPORTANT
Before using these respirators,
you must determine the following:
1. The type of contaminant(s)
for which the respirator is
being selected.
2. The concentration level of
contaminant(s).
3. Whether the respirator can be
properly fitted on the wearer’s
face. All respirator instructions,
warnings and use and time
limitations must also be read
and understood by the wearer
before use.
Please contact your local 3M
distributor to place an order.
To determine the location of the
3M distributor nearest you, call
1-800-328-1667. In Canada call
800-265-1840 extension 6137.
Technical Assistance U.S.
1-800-243-4630
Sales Assistance U.S.
1-800-896-4223
Fax On Demand U.S. and Canada
1-800-646-1655
Fax On Demand Outside U.S. and Canada
651-732-0131
Internet
www.3M.com/occsafety
E-mail
[email protected]
For other 3M products
1-800-3M HELPS
In Canada, contact:
3M Canada Company, OH&ESD
P.O. Box 5757
London, Ontario N6A 4T1
1-800-267-4414
or 1-800-265-1840, ext. 6137
Internet
www.3M.com/intl/CA/ohes.html
3M Canada E-mail
[email protected]
3M Occupational Health and Environmental Safety Division
3M Center, Building 235-2W-70
St. Paul, MN 55144-1000
Technical Assistance In Mexico
01-800-712-0646
Technical Assistance In Brazil