3 Half and Full Facepiece Respirators 6000 Series 4017 page 1 of 4 Issue Date 06/01/00 Unmatched performance and comfort 3M™ Respirators 6000 Series provide low-maintenance and offer the user comfort and convenience coupled with the cost savings of a reusable respirator. Features/Benefits • Used with 3M™ Filters and Cartridges, these respirators are among the lightest available. • The swept back design of the cartridges improves balance and visibility. • 6000 series facepieces cost about half as much as typical reusable respirators. • Remarkably comfortable, soft, lightweight facepiece and easy-to-adjust head straps. • Reusable. Just dispose of the cartridges/filters when used to capacity. • Can be disassembled, cleaned and reused. • NIOSH approved for negative pressure air purifying and positive pressure dual airline applications. • Supplied with reclosable storage bag. • The half and full facepieces are each available in 3 sizes (small, medium, large) to comfortably fit many faces. The 6000 Series respirators can be used in dual airline mode: • Available with both backmounted and front-mounted breathing tubes. 3 3 3 The 3M™ Half and Full Facepiece Respirators 6000 Series with replaceable cartridges/filters provide outstanding comfort, versatility and reliability. • Systems can be used in combination with NIOSH approved 3M™ 2000 Series Filters or 3M™ 6000 Series Cartridges and P100 Filter/Cartridges. • Cartridge/filter connections provide negative and positive pressure capability in one respirator assembly. • Can be used on both high and low pressure systems. • Wearer can disconnect the airline at the air regulating valve and the system is changed to a filters/cartridges air purifying mode—then back to supplied air system with a simple reconnection of the airline. • Small diameter breathing tubes are simple to work with and easy to clean and decontaminate. ! WARNING These respirators help reduce exposure to certain airborne contaminants. Misuse may result in sickness or death. Before use, the wearer must read and understand User Instructions provided as a part of product packaging. Time use limitations may apply. For proper use, see supervisor, packaging or call 3M OH&ESD Technical Service, call 1-800-243-4630. In Canada, call 1-519-452-6137 or 1-800-265-1840, ext. 6137. 3M™ Half and Full Facepiece Respirators 6000 Series (continued) 4017 page 2 of 4 Half Facepieces Full Facepieces 6100 Half Facepiece (Small) 6200 Half Facepiece (Medium) 6300 Half Facepiece (Large) 6700 Full Facepiece (Small) 6800 Full Facepiece (Medium) 6900 Full Facepiece (Large) 2000 Series, 7093, 5N11, 5P71 Filters and Accessories 7 6 1 3 209 20 7 8 3 HF 3 209 3 2 076 1 3 2091 P100 Filter 11J6200 NIOSH 20 9 2078 P95 Filter with nuisance level organic vapor and acid gas relief* 11J6200 NIOSH 2096 P100 Filter with nuisance level acid gas relief* 3 11J6200 NIOSH 20 9 3P100 209 3P100 209 3P100 7 3 2076HF P95 Filter with hydrogen fluoride, nuisance level acid gas relief* 207 2071 P95 Filter 11J6200 NIOSH 6 P95 HYDROGEN FLUORIDE 00J0000 NIOSH 11J6200 NIOSH 1 1 20 7 8 3 P95 2 076 HF 207 3 P95 2097 P100 Filter with nuisance level organic vapor relief* *Nuisance levels refer to concentrations below the OSHA PEL. 3 NO. PART 1 50 3 NO. PART 2 50 DO NO FRO NIN G: QU IVE FIT T TAT 3 3M™ Fit Test Respirator 3M developed this product specifically for quantitative fit testing. Available in small (6100Q), medium (6200Q) and large (6300Q). A probe has been added for fit testing purposes. Do not use for respiratory protection. 501 Filter Retainer (Use with the 5N11 and 5P71 Filters) OVE TRID GE 502 Filter Adapter (Use with the 2000 Series and 7093 Filters) 3M™ Fit Test Kits • FT-10 Qualitative Fit Test Apparatus (sweet solution) • FT-20 Training and Fit Testing Case (sweet solution) • FT-30 Qualitative Fit Test Apparatus (bitter solution) S PIRATO R . AR 5P71 P95 Filter (Use with the 501 Filter Retainer) T RE W TI 5N11 N95 Filter (Use with the 501 Filter Retainer) ES AN 7093 P100 Filter EM TR AR MC 3M™ Quantitative Fit Test Adapter 601 (for use with all 3M bayonet attachment facepieces) 3M™ Half and Full Facepiece Respirators 6000 Series (continued) 4017 page 3 of 4 NIOSH Approval* Product Number NIOSH Approval* 6001 Certain organic vapors (a)(b) 60921 P100/Certain organic vapors (a)(b) 6002 Chlorine, hydrogen chloride, and sulfur dioxide or chlorine dioxide or hydrogen sulfide (escape only) (a)(b) 60922 6003 Certain organic vapors, chlorine, hydrogen chloride, and sulfur dioxide or hydrogen sulfide (escape only) or hydrogen fluoride (a)(b) P100/Chlorine, hydrogen chloride, and sulfur dioxide or chlorine dioxide or hydrogen sulfide (escape only) (a)(b) 60923 P100/Certain organic vapors, chlorine, hydrogen chloride, and sulfur dioxide or hydrogen sulfide (escape only) or hydrogen fluoride (a)(b) Product Number 6004 Ammonia and methylamine (a)(b) 60924 6005 Formaldehyde and certain organic vapors (a)(b)(c) P100/Ammonia and methylamine (a)(b) 60925 P100/Formaldehyde and certain organic vapors (a)(b) 60926 P100/Certain organic vapors, chlorine, hydrogen chloride, chlorine dioxide, sulfur dioxide, hydrogen sulfide (escape only) ammonia/methylamine, formaldehyde or hydrogen fluoride (a)(b)(c) 60929 P100/Mercury vapor or chlorine gas (a)(b) 6006 6009 Certain organic vapors, chlorine, hydrogen chloride, chlorine dioxide, sulfur dioxide, hydrogen sulfide (escape only) ammonia/methylamine, formaldehyde or hydrogen fluoride (a)(b)(c) Mercury vapor or chlorine gas * For respiratory protection against the following contaminants up to 10X PEL with half facepiece respirators or 50X PEL with full facepiece respirators. (a) All respirators and respirator/filter assemblies can be used up to the NIOSH approval limits, 10X PEL for half facepiece respirators or 50X PEL for full facepiece respirators or the maximum use concentration allowable in applicable OSHA standards, whichever is lower. (b) For specific usage, limitations and warning information, see respirator and/or filter packaging, or call 3M OH&ESD Technical Service 1-800-243-4630. In Canada call 1-800-265-1840. (c) OSHA regulations require that gas-proof goggles be worn with half facepiece respirators when used against formaldehyde. Full Facepiece Replacement Parts and Accessories 6000 Series 6000 Half Facepiece Replacement Parts Accessories 7883 6889 6892 6893 6894 6895 6896 6897 6898 6899 6878 6885 6886 Neck Strap Assembly Exhalation Valve Center Adapter Assembly Inhalation Valve Nose Cup Assembly Inhalation Gasket Center Adapter Gasket Head Harness Assembly Lens Assembly Lens Frame Kit Spectacle Kit Face Shield Cover Tinted Lens Cover Half Facepiece Replacement Parts 6000 Series Replacement Parts 6281 6889 6893 6895 Respirator Strap Assembly Exhalation Valve Inhalation Valve Inhalation Gasket Facepieces per bag Facepieces per case 1 24 6000 Full Facepiece Facepieces per box Facepieces per case 1 4 3M™ Half and Full Facepiece Respirators 6000 Series (continued) 4017 page 4 of 4 To complete a 3M™ Dual Airline Respirator System, select a facepiece, an adapter kit and an air supply hose. For example: 6800 + SA-2000 + W-9435-100 = complete system. High Pressure Low Pressure Standard Back-Mounted Adapter Kit. Includes SA-2500 Breathing Tube, GVP-127 Belt and SA-1009 Air Regulator or SA-1029 Connector (low pressure) SA-2000 SA-2000LP Combination Back-Mounted Adapter Kit. Includes 2600 Breathing Tube, GVP-127 Belt and SA-1009 Regulator or SA-1029 Connector (low pressure). Cartridges/Filters not included. SA-2100 SA-2100LP Standard Front-Mounted Adapter Kit. Includes SA-1500 Breathing Tube, GVP-127 Belt, and SA-1009 Regulator or SA-1029 Connector (Low pressure) SA-1000 SA-1000LP Combination Front-Mounted Adapter Kit. Includes SA-1600 Breathing Tube, GVP-127 Belt, and SA-1009 Regulator or SA-1029 Connector (low pressure). Cartridges/Filters not included. SA-1100 SA-1100LP Accessories and replacement parts Note: For more information on 3M™ Dual Airline Supplied Air Systems, please call 3M’s Fax On Demand line at 1-800-646-1655 and order document number 4024. Refer to Fax On Demand document number 9011 for National Stock Numbers. ! IMPORTANT Before using these respirators, you must determine the following: 1. The type of contaminant(s) for which the respirator is being selected. 2. The concentration level of contaminant(s). 3. Whether the respirator can be properly fitted on the wearer’s face. All respirator instructions, warnings and use and time limitations must also be read and understood by the wearer before use. Please contact your local 3M distributor to place an order. To determine the location of the 3M distributor nearest you, call 1-800-328-1667. In Canada call 800-265-1840 extension 6137. Technical Assistance U.S. 1-800-243-4630 Sales Assistance U.S. 1-800-896-4223 Fax On Demand U.S. and Canada 1-800-646-1655 Fax On Demand Outside U.S. and Canada 651-732-0131 Internet www.3M.com/occsafety E-mail [email protected] For other 3M products 1-800-3M HELPS In Canada, contact: 3M Canada Company, OH&ESD P.O. Box 5757 London, Ontario N6A 4T1 1-800-267-4414 or 1-800-265-1840, ext. 6137 Internet www.3M.com/intl/CA/ohes.html 3M Canada E-mail [email protected] 3M Occupational Health and Environmental Safety Division 3M Center, Building 235-2W-70 St. Paul, MN 55144-1000 Technical Assistance In Mexico 01-800-712-0646 Technical Assistance In Brazil 0800-550705