ETC 5D15.060

1.8 Watt Dual Series DC/DC Converters
Features
Description
n
Low Profile Case (0.375" High)
n
Low Noise Operation
n
“LC” Section Input Filter to Reduce Reflected Ripple
n
Wide Input Voltage Range
These 1.8 Watt Dual DC/DC Converters are designed for high
performance Industrial data acquisition systems and board
level products. The converter consists of a rugged bipolar
switching stage, isolation transformer, and high regulation
linear post regulator for low noise/highly stable DC outputs.
n
High Isolation Breakdown Voltage
(500 VDC Minimum)
n
Long Term Output Fault Survival
n
100% Burn-In, 100% Tested
n
5 Year Warranty
Selection Chart
Model
Input Range
VDC
MIN
MAX
Outputs
VDC
Outputs
mA
5D12.075
4.60
5.50
±12.0
±75
5D15.060
4.60
5.50
±15.0
±60
12D12.075
10.80
13.80
±12.0
±75
12D15.060
10.80
13.80
±15.0
±60
1.8 Watt Dual Series Block Diagram
ISOLATION
TRANSFORMER
A
POSITIVE
REGULATOR
3 + OUTPUT
1µF
1µF
- INPUT 2
LC
INPUT
FILTER
BIPOLAR
PUSH-PULL
INVERTER
4 CMN
10µF
10µF
NEGATIVE
REGULATOR
5 - OUTPUT
BANDGAP REFERENCE
SIX-SIDED SHIELDED STEEL CASE
2401 Stanwell Drive
Concord, CA 94520-4841
(510) 687-4411 • Fax (510) 687-3333
http://www.calex.com
1
CALEX FaxFACTS: 119
+ INPUT 1
1.8 Watt Dual Series DC/DC Converters
Input Parameters*
Model
Voltage Range
Reflected Ripple, 0-20MHz bw
Input Current Full Load
No Load
Efficiency
Switching Frequency
Maximum Input Overvoltage,
100ms No Damage
Turn-on Time, 1% Output Error (2)
MIN
MAX
TYP
MAX
TYP
TYP
TYP
TYP
5D12.075 5D15.060
4.60
5.50
100
200
650
130
55
55
12D12.075 12D15.060
10.80
13.80
80
150
265
45
57
55
MAX
6.2
14.5
VDC
TYP
4
4
ms
Recommended Fuse
Units
VDC
mA P-P
mA
%
kHz
Slow Blow Type (3)
Output Parameters*
Model
5D12.075
Output Voltage
MIN
MAX
MIN
TYP
MAX
Rated Load (4)
Voltage Range
100% Load
Output Balance
(Plus to Minus Output, Full Load)
12D12.075
5D15.060
±12
0
±75
11.88
12.00
12.12
12D15.060
±15
0
±60
14.85
15.00
15.15
Units
VDC
mA
VDC
MAX
1.0
Line Regulation
Vin = Min-Max VDC
Short Term Stability (5)
TYP
MAX
TYP
MAX
TYP
0.1
0.2
0.1
0.2
0.1
%
Long Term Stability
TYP
0.4
%/kHrs
Load Regulation 0-100% Load
%
%
%
Transient Response (6)
TYP
100
µs
Dynamic Response (7)
TYP
15
mV peak
Input Ripple Rejection (7)
TYP
TYP
MAX
TYP
MAX
60
15
30
150
300
dB
Noise, 0-20MHz bw
Temperature Coefficient
Short Circuit Protection to
Common for all Outputs
A
(3)
(4)
(5)
(6)
All parameters measured at Tc= 25° C, nominal input voltage
and full rated load unless otherwise noted. Refer to the
CALEX Application Notes for the definition of terms,
measurement circuits and other information.
Turn on time is defined as the time from the application of power
until the output is within 1% if its final value.
Determine the correct fuse size by calculating the maximum DC
current drain at low line input, maximum load (or use the supplied
curves) and then adding 20 to 25% to get the desired fuse size.
No minimum load required.
Short term stability is specified after a 30 minute warm-up at full
load and with constant line, load and ambient conditions.
The transient response is specified as the time required for the
output to settle from a 100% step load change (rise time of step =
2µ Sec) to a 1% error band.
2401 Stanwell Drive
Concord, CA 94520-4841
(510) 687-4411 • Fax (510) 687-3333
(7)
(8)
(9)
Dynamic response is the peak overshoot voltage during the
transient response as defined in note 6 above.
The functional temperature range is intended to give an additional
data point for use in evaluating this power supply. At the low
functional temperature the power supply will function with no side
effects, however sustained operation at the high functional
temperature will reduce expected operational life. The data sheet
specifications are not guaranteed over the functional temperature
range.
The case thermal impedance is specified as the case temperature
rise over ambient per package watt dissipated.
http://www.calex.com
2
CALEX FaxFACTS: 119
(2)
ppm/°C
Short Term, 1 Minute Maximum
NOTES:
*
mV P-P
1.8 Watt Dual Series DC/DC Converters
General Specifications *
All Models
Isolation
Isolation Voltage
10µA Leakage
Input-Output
Input to Output
Capacitance
Environmental
Case Operating Range
No Derating
Case Functional Range (8)
Storage Range
Thermal Impedance (9)
Units
MIN
500
VDC
TYP
30
pF
MIN
MAX
MIN
MAX
MIN
MAX
TYP
-25
80
-30
90
-55
100
16.5
°C/Watt
TYP
0.9
oz
°C
BOTTOM VIEW
°C
°C
General
SIDE VIEW
Mechanical tolerances unless otherwise noted:
X.XX dimensions: ±0.020 inches
X.XXX dimensions: ±0.005 inches
Unit Weight
Mounting Kits
MS6 & MS15
Seal around terminals is not hermetic. Do not immerse units in any
liquid.
Pin
1
2
3
4
5
Typical Performance (Tc=25°C; Full Rated Load).
Function
+INPUT
-INPUT
+OUTPUT
CMN
-OUTPUT
5D EFFICIENCY Vs. LINE INPUT
65
100% FULL LOAD
EFFICIENCY (%)
60
55
50% FULL LOAD
50
45
40
35
4.6
4.8
5.0
5.2
5.4
5.6
A
LINE INPUT (VOLTS)
5D EFFICIENCY Vs. LOAD
5D INPUT CURRENT Vs. LINE INPUT
70
EFFICIENCY (%)
60
LINE = 4.6VDC
LINE = 5VDC
50
40
LINE = 5.5VDC
30
0.6
0.5
100% FULL LOAD
0.4
0.3
50% FULL LOAD
0.2
0.1
20
0.0
0
20
40
60
80
100
0
LOAD (%)
2401 Stanwell Drive
Concord, CA 94520-4841
(510) 687-4411 • Fax (510) 687-3333
1
2
3
4
5
6
LINE INPUT (VOLTS)
http://www.calex.com
3
CALEX FaxFACTS: 119
INPUT CURRENT (AMPS)
0.7
1.8 Watt Dual Series DC/DC Converters
Typical Performance (Tc=25°C; Full Rated Load).
12D EFFICIENCY Vs. LINE INPUT
OUTPUT LOADING CHART
65
-Io PERCENT OF FULL LOAD
200
EFFICIENCY (%)
60
100% FULL LOAD
55
50
45
50% FULL LOAD
40
35
-Io
+Io
150
100
50
0
10
11
12
13
14
0
50
LINE INPUT (VOLTS)
100
150
200
+Io PERCENT OF FULL LOAD
12D EFFICIENCY Vs. LOAD
OUTPUT VOLTAGE Vs CASE TEMPERATURE
70
0.8
EFFICIENCY (%)
60
NORMALIZED OUTPUT (%)
LINE = 10.8VDC
LINE = 12VDC
50
40
LINE = 13.8VDC
30
0.6
NEGATIVE OUTPUT
0.4
POSITIVE OUTPUT
0.2
0.0
-0.2
-0.4
-0.6
20
-0.8
0
20
40
60
80
100
-30
LOAD (%)
-20
-10
0
10
20
30
40
50
60
70
80
CASE TEMPERATURE (Deg C)
12D INPUT CURRENT Vs. LINE INPUT
OUTPUT IMPEDANCE Vs. FREQUENCY
0.30
1
100% RATED LOAD
IMPEDANCE (OHMS)
A
0.20
0.15
0.10
50% RATED LOAD
NEGATIVE OUTPUT
.1
.01
0.05
0.00
.001
0
2
4
6
8
10
12
14
10
LINE INPUT (VOLTS)
2401 Stanwell Drive
Concord, CA 94520-4841
(510) 687-4411 • Fax (510) 687-3333
100
1K
10K
100K
1M
FREQUENCY (Hz)
http://www.calex.com
4
CALEX FaxFACTS: 119
INPUT CURRENT (AMPS)
POSITIVE OUTPUT
0.25