HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Features CAS Latency and Frequency CAS Latency 2 2.5 Maximum Operating Frequency (MHz) DDR200 DDR266A DDR333 -8 -7 -6 100 133 133 125 143 166 • Double data rate architecture: two data transfers per clock cycle • Bidirectional data strobe (DQS) is transmitted and received with data, to be used in capturing data at the receiver • DQS is edge-aligned with data for reads and is center-aligned with data for writes • Differential clock inputs (CK and CK) • Four internal banks for concurrent operation • Data mask (DM) for write data. The x16 organi- • • • • • • • • • • zation has two (LDM, UDM), one per byte. DLL aligns DQ and DQS transitions with CK transitions Commands entered on each positive CK edge; data and data mask referenced to both edges of DQS Burst Lengths: 2, 4, or 8 CAS Latency: 2, 2.5, (3) Auto Precharge option for each burst access Auto Refresh and Self Refresh Modes 15.6 µs Maximum Average Periodic Refresh Interval (4k refresh) 2.5V (SSTL_2 compatible) I/O VDDQ = 2.5V ± 0.2V / VDD = 2.5V ± 0.2V TSOP66 package Description The 128Mb DDR SDRAM is a high-speed CMOS, dynamic random-access memory containing 134,217,728 bits. It is internally configured as a quad-bank DRAM. dent with the Read or Write command are used to select the bank and the starting column location for the burst access. The 128Mb DDR SDRAM uses a double-data-rate architecture to achieve high-speed operation. The double data rate architecture is essentially a 2n prefetch architecture with an interface designed to transfer two data words per clock cycle at the I/O pins. A single read or write access for the 128Mb DDR SDRAM effectively consists of a single 2n-bit wide, one clock cycle data transfer at the internal DRAM core and two corresponding n-bit wide, onehalf-clock-cycle data transfers at the I/O pins. The DDR SDRAM provides for programmable Read or Write burst lengths of 2, 4 or 8 locations. An Auto Precharge function may be enabled to provide a self-timed row precharge that is initiated at the end of the burst access. A bidirectional data strobe (DQS) is transmitted externally, along with data, for use in data capture at the receiver. DQS is a strobe transmitted by the DDR SDRAM during Reads and by the memory controller during Writes. DQS is edge-aligned with data for Reads and center-aligned with data for Writes. The 128Mb DDR SDRAM operates from a differential clock (CK and CK; the crossing of CK going HIGH and CK going LOW is referred to as the positive edge of CK). Commands (address and control signals) are registered at every positive edge of CK. Input data is registered on both edges of DQS, and output data is referenced to both edges of DQS, as well as to both edges of CK. Read and write accesses to the DDR SDRAM are burst oriented; accesses start at a selected location and continue for a programmed number of locations in a programmed sequence. Accesses begin with the registration of an Active command, which is then followed by a Read or Write command. The address bits registered coincident with the Active command are used to select the bank and row to be accessed. The address bits registered coinci2002-05-06 Page 1 of 76 As with standard SDRAMs, the pipelined, multibank architecture of DDR SDRAMs allows for concurrent operation, thereby providing high effective bandwidth by hiding row precharge and activation time. An auto refresh mode is provided along with a power-saving power-down mode. All inputs are compatible with the JEDEC Standard for SSTL_2. All outputs are SSTL_2, Class II compatible. Note: The functionality described and the timing specifications included in this data sheet are for the DLL Enabled mode of operation. HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Ordering Information Part Number CAS Latency Clock (MHz) CAS Latency Clock (MHz) Speed 100 DDR200 HYB25D128400AT(L)-8 *) Org. x4 HYB25D128800AT(L)-8 *) 125 x8 HYB25D128160AT(L)-8 *) x 16 HYB25D128400AT(L)-7 *) x4 HYB25D128800AT(L)-7 *) 2.5 143 2 133 DDR266A HYB25D128160AT(L)-7 *) HYB25D128160AT(L)-6 *) x8 66 pin TSOP-II x 16 HYB25D128400AT(L)-6 *) HYB25D128800AT(L)-6 *) Package x4 166 133 DDR333 x8 x 16 *) Low Power Versions have a “L” in the partnumber, f.e. HYB25D128400ATL-8. These components are specifically selected for low IDD6 Self Refresh currents. Page 2 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Pin Configuration VDD VDD VDD 1 66 VSS VSS VSS NC DQ0 VDDQ NC DQ0 VDDQ DQ1 2 3 4 65 64 63 DQ15 VSSQ DQ14 DQ7 VSSQ NC NC VSSQ NC VDDQ NC DQ0 DQ1 DQ2 5 62 DQ13 DQ6 DQ3 VSSQ NC NC VDDQ NC VSSQ NC DQ2 VDDQ NC DQ3 VSSQ DQ3 DQ4 VDDQ DQ5 6 7 8 9 10 61 60 59 58 57 VDDQ DQ12 DQ11 VSSQ DQ10 VDDQ NC DQ5 VSSQ NC VDDQ NC NC VSSQ NC DQ6 11 56 DQ9 DQ4 DQ2 VSSQ VSSQ 12 55 VDDQ VDDQ VDDQ 13 14 15 16 54 DQ8 NC NC 53 52 51 NC VSSQ UDQS NC VSSQ DQS NC VSSQ DQS 17 18 19 50 49 48 NC VREF VSS NC VREF VSS NC VREF VSS 20 47 UDM DM DM 46 45 44 CK CK CK CK CK CK DQ1 VSSQ NC NC NC NC DQ7 NC VDDQ NC NC VDD NC VDDQ NC NC VDD NC V DDQ LDQS NC V DD NC NC NC LDM WE CAS WE CAS WE CAS RAS RAS RAS 21 22 23 CKE CKE CKE CS NC CS NC CS NC 24 25 43 42 NC NC NC NC NC NC BA0 BA1 A10/AP BA0 BA1 A10/AP BA0 BA1 A10/AP A0 A1 A2 A0 A1 A2 A0 A1 A2 26 27 28 29 41 40 39 38 A11 A9 A8 A7 A11 A9 A8 A7 A11 A9 A8 A7 30 31 37 36 A6 A5 A6 A5 A6 A5 A3 VDD A3 VDD A3 VDD 32 33 35 34 A4 VSS A4 VSS A4 VSS 8Mb x 16 16Mb x 8 32Mb x 4 Page 3 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Input/Output Functional Description Symbol Type Function CK, CK Input Clock: CK and CK are differential clock inputs. All address and control input signals are sampled on the crossing of the positive edge of CK and negative edge of CK. Output (read) data is referenced to the crossings of CK and CK (both directions of crossing). CKE Input Clock Enable: CKE HIGH activates, and CKE Low deactivates, internal clock signals and device input buffers and output drivers. Taking CKE Low provides Precharge Power-Down and Self Refresh operation (all banks idle), or Active Power-Down (row Active in any bank). CKE is synchronous for power down entry and exit, and for self refresh entry. CKE is asynchronous for self refresh exit. CKE must be maintained high throughout read and write accesses. Input buffers, excluding CK, CK and CKE are disabled during power-down. Input buffers, excluding CKE, are disabled during self refresh. CS Input Chip Select: All commands are masked when CS is registered HIGH. CS provides for external bank selection on systems with multiple banks. CS is considered part of the command code. The standard pinout includes one CS pin. RAS, CAS, WE Input Command Inputs: RAS, CAS and WE (along with CS) define the command being entered. DM UDM, LDM Input Input Data Mask: DM is an input mask signal for write data. Input data is masked when DM is sampled HIGH coincident with that input data during a Write access. DM is sampled on both edges of DQS. Although DM pins are input only, the DM loading matches the DQ and DQS loading. For the x16, LDM corresponds to the data on DQ0-DQ7; UDM corresponds to the data on DQ8-DQ15. BA0, BA1 Input Bank Address Inputs: BA0 and BA1 define to which bank an Active, Read, Write or Precharge command is being applied. BA0 and BA1 also determines if the mode register or extended mode register is to be accessed during a MRS or EMRS cycle. A0 - A11 Input Address Inputs: Provide the row address for Active commands, and the column address and Auto Precharge bit for Read/Write commands, to select one location out of the memory array in the respective bank. A10 is sampled during a Precharge command to determine whether the Precharge applies to one bank (A10 LOW) or all banks (A10 HIGH). If only one bank is to be precharged, the bank is selected by BA0, BA1. The address inputs also provide the op-code during a Mode Register Set command. DQ Input/Output Data Input/Output: Data bus. DQS UDQS,LDQS Input/Output Data Strobe: Output with read data, input with write data. Edge-aligned with read data, centered in write data. Used to capture write data.For the x16, LDQS corresponds to the data on DQ0-DQ7; UDQS corresponds to the data on DQ8-DQ15. NC No Connect: No internal electrical connection is present. VDDQ Supply DQ Power Supply: 2.5V ± 0.2V. VSSQ Supply DQ Ground VDD Supply Power Supply: 2.5V ± 0.2V. VSS Supply Ground VREF Supply SSTL_2 reference voltage: (VDDQ / 2) Page 4 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Control Logic 14 2 Bank2 Bank3 CK, CK DLL 2 8192 I/O Gating DM Mask Logic 1024 (x8) Column Decoder 4 Column-Address Counter/Latch COL0 1 4 1 DQS Generator COL0 8 8 Write FIFO & Drivers Input Register 1 Mask 1 1 1 4 4 4 clk clk out in Data 4 2 8 10 11 Drivers 8 Sense Amplifiers Data 4 MUX Bank0 Memory Array (4096 x 1024 x 8) Read Latch 4096 CK, CK DQS DQ0-DQ3, DM DQS 1 Receivers 14 Refresh Counter 12 A0-A11, BA0, BA1 Address Register 12 12 Bank Control Logic Mode Registers Bank0 Row-Address Latch & Decoder Bank1 Row-Address MUX CKE CK CK CS WE CAS RAS Command Decode Block Diagram (32Mb x 4) 4 COL0 1 Note: This Functional Block Diagram is intended to facilitate user understanding of the operation of the device; it does not represent an actual circuit implementation. Note: DM is a unidirectional signal (input only), but is internally loaded to match the load of the bidirectional DQ and DQS signals. 2002-05-06 Page 5 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Control Logic 14 2 Bank2 Bank3 CK, CK DLL 2 8192 I/O Gating DM Mask Logic 512 (x16) 8 16 Write FIFO & Drivers 1 1 8 8 8 clk clk out in Data 8 9 Column-Address Counter/Latch COL0 1 1 Input Register 1 Mask 1 2 16 Column Decoder 10 8 DQS Generator COL0 16 Drivers 16 Sense Amplifiers Data 8 MUX Bank0 Memory Array (4096 x 512 x 16) Read Latch 4096 CK, CK DQS DQ0-DQ7, DM DQS 1 Receivers 14 Refresh Counter 12 A0-A11, BA0, BA1 Address Register 12 12 Bank Control Logic Mode Registers Bank0 Row-Address Latch & Decoder Bank1 Row-Address MUX CKE CK CK CS WE CAS RAS Command Decode Block Diagram (16Mb x 8) 8 COL0 1 Note: This Functional Block Diagram is intended to facilitate user understanding of the operation of the device; it does not represent an actual circuit implementation. Note: DM is a unidirectional signal (input only), but is internally loaded to match the load of the bidirectional DQ and DQS signals. Page 6 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Control Logic 14 2 Bank3 CK, CK 2 8192 I/O Gating DM Mask Logic 256 (x32) 16 32 Write FIFO & Drivers Input Register 1 Mask 1 1 1 16 16 16 clk clk out in Data 16 8 Column-Address Counter/Latch COL0 1 1 DQS Generator 2 32 Column Decoder 9 16 COL0 32 Drivers 32 Sense Amplifiers Data 16 MUX Bank0 Memory Array (4096 x 256x 32) Read Latch 4096 CK, CK DQS DQ0-DQ15, DM LDQS, UDQS 1 Receivers 14 Refresh Counter 12 A0-A11, BA0, BA1 Address Register 12 12 Bank2 DLL Bank Control Logic Mode Registers Bank0 Row-Address Latch & Decoder Bank1 Row-Address MUX CKE CK CK CS WE CAS RAS Command Decode Block Diagram (8Mb x 16) 16 COL0 2 Note: This Functional Block Diagram is intended to facilitate user understanding of the operation of the device; it does not represent an actual circuit implementation. Note: UDM and LDM are unidirectional signals (input only), but is internally loaded to match the load of the bidirectional DQ , UDQS and LDQS signals. 2002-05-06 Page 7 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Functional Description The 128Mb DDR SDRAM is a high-speed CMOS, dynamic random-access memory containing 134,217,728 bits. The 128Mb DDR SDRAM is internally configured as a quad-bank DRAM. The 128Mb DDR SDRAM uses a double-data-rate architecture to achieve high-speed operation. The doubledata-rate architecture is essentially a 2n prefetch architecture, with an interface designed to transfer two data words per clock cycle at the I/O pins. A single read or write access for the 128Mb DDR SDRAM consists of a single 2n-bit wide, one clock cycle data transfer at the internal DRAM core and two corresponding n-bit wide, one-half clock cycle data transfers at the I/O pins. Read and write accesses to the DDR SDRAM are burst oriented; accesses start at a selected location and continue for a programmed number of locations in a programmed sequence. Accesses begin with the registration of an Active command, which is then followed by a Read or Write command. The address bits registered coincident with the Active command are used to select the bank and row to be accessed (BA0, BA1 select the bank; A0-A11 select the row). The address bits registered coincident with the Read or Write command are used to select the starting column location for the burst access. Prior to normal operation, the DDR SDRAM must be initialized. The following sections provide detailed information covering device initialization, register definition, command descriptions and device operation. Initialization DDR SDRAMs must be powered up and initialized in a predefined manner. Operational procedures other than those specified may result in undefined operation. The following criteria must be met: No power sequencing is specified during power up or power down given the following criteria: VDD and VDDQ are driven from a single power converter output VTT meets the specification A minimum resistance of 42 ohms limits the input current from the VTT supply into any pin and VREF tracks VDDQ/2 or The following relationship must be followed: VDDQ is driven after or with VDD such that VDDQ < VDD + 0.3 V VTT is driven after or with VDDQ such that VTT < VDDQ + 0.3V VREF is driven after or with VDDQ such that VREF < VDDQ + 0.3V The DQ and DQS outputs are in the High-Z state, where they remain until driven in normal operation (by a read access). After all power supply and reference voltages are stable, and the clock is stable, the DDR SDRAM requires a 200µs delay prior to applying an executable command. Once the 200µs delay has been satisfied, a Deselect or NOP command should be applied, and CKE should be brought HIGH. Following the NOP command, a Precharge ALL command should be applied. Next a Mode Register Set command should be issued for the Extended Mode Register, to enable the DLL, then a Mode Register Set command should be issued for the Mode Register, to reset the DLL, and to program the operating parameters. 200 clock cycles are required between the DLL reset and any executable command. During the 200 cycles of clock for DLL locking, a Deselect or NOP command must be applied. After the 200 clock cycles, a Precharge ALL command should be applied, placing the device in the “all banks idle” state. Once in the idle state, two AUTO REFRESH cycles must be performed. Additionally, a Mode Register Set command for the Mode Register, with the reset DLL bit deactivated (i.e. to program operating parameters without resetting the DLL) must be performed. Following these cycles, the DDR SDRAM is ready for normal operation. Page 8 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Register Definition Mode Register The Mode Register is used to define the specific mode of operation of the DDR SDRAM. This definition includes the selection of a burst length, a burst type, a CAS latency, and an operating mode. The Mode Register is programmed via the Mode Register Set command (with BA0 = 0 and BA1 = 0) and retains the stored information until it is programmed again or the device loses power (except for bit A8, which is self-clearing). Mode Register bits A0-A2 specify the burst length, A3 specifies the type of burst (sequential or interleaved), A4-A6 specify the CAS latency, and A7-A11 specify the operating mode. The Mode Register must be loaded when all banks are idle, and the controller must wait the specified time before initiating the subsequent operation. Violating either of these requirements results in unspecified operation. Burst Length Read and write accesses to the DDR SDRAM are burst oriented, with the burst length being programmable. The burst length determines the maximum number of column locations that can be accessed for a given Read or Write command. Burst lengths of 2, 4, or 8 locations are available for both the sequential and the interleaved burst types. Reserved states should not be used, as unknown operation or incompatibility with future versions may result. When a Read or Write command is issued, a block of columns equal to the burst length is effectively selected. All accesses for that burst take place within this block, meaning that the burst wraps within the block if a boundary is reached. The block is uniquely selected by A1-Ai when the burst length is set to two, by A2-Ai when the burst length is set to four and by A3-Ai when the burst length is set to eight (where Ai is the most significant column address bit for a given configuration). The remaining (least significant) address bit(s) is (are) used to select the starting location within the block. The programmed burst length applies to both Read and Write bursts. 2002-05-06 Page 9 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Mode Register Operation BA1 BA0 0* 0* A11 A10 A9 A8 A7 A6 A5 A4 CAS Latency Operating Mode A3 BT A2 Burst Length A11 - A9 A8 A7 A6 - A0 Operating Mode 0 0 0 Valid Normal operation Do not reset DLL A3 Burst Type 0 Sequential 0 1 0 Valid Normal operation in DLL Reset 1 Interleave 0 0 1 Test Mode − − − Reserved CAS Latency A1 A0 Address Bus Mode Register Burst Length A6 A5 A4 Latency A2 A1 A0 Burst Length 0 0 0 Reserved 0 0 0 Reserved 0 0 1 Reserved 0 0 1 2 0 1 0 2 0 1 0 4 0 1 1 3 (optional) 0 1 1 8 1 0 0 Reserved 1 0 0 Reserved 1 0 1 Reserved (1.5**) 1 0 1 Reserved 1 1 0 2.5 1 1 0 Reserved 1 1 1 Reserved 1 1 1 Reserved * BA0 and BA1 must be 0, 0 to select the Mode Register (vs. the Extended Mode Register). ** will be supported in future versions of this product Page 10 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Burst Definition Starting Column Address Order of Accesses Within a Burst Burst Length A2 A1 A0 Type = Sequential Type = Interleaved 0 0-1 0-1 1 1-0 1-0 0 0 0-1-2-3 0-1-2-3 0 1 1-2-3-0 1-0-3-2 1 0 2-3-0-1 2-3-0-1 1 1 3-0-1-2 3-2-1-0 0 0 0 0-1-2-3-4-5-6-7 0-1-2-3-4-5-6-7 0 0 1 1-2-3-4-5-6-7-0 1-0-3-2-5-4-7-6 0 1 0 2-3-4-5-6-7-0-1 2-3-0-1-6-7-4-5 0 1 1 3-4-5-6-7-0-1-2 3-2-1-0-7-6-5-4 1 0 0 4-5-6-7-0-1-2-3 4-5-6-7-0-1-2-3 1 0 1 5-6-7-0-1-2-3-4 5-4-7-6-1-0-3-2 1 1 0 6-7-0-1-2-3-4-5 6-7-4-5-2-3-0-1 1 1 1 7-0-1-2-3-4-5-6 7-6-5-4-3-2-1-0 2 4 8 Notes: 1. For a burst length of two, A1-Ai selects the two-data-element block; A0 selects the first access within the block. 2. For a burst length of four, A2-Ai selects the four-data-element block; A0-A1 selects the first access within the block. 3. For a burst length of eight, A3-Ai selects the eight-data- element block; A0-A2 selects the first access within the block. 4. Whenever a boundary of the block is reached within a given sequence above, the following access wraps within the block. Burst Type Accesses within a given burst may be programmed to be either sequential or interleaved; this is referred to as the burst type and is selected via bit A3. The ordering of accesses within a burst is determined by the burst length, the burst type and the starting column address, as shown in Burst Definition on page 11. Read Latency The Read latency, or CAS latency, is the delay, in clock cycles, between the registration of a Read command and the availability of the first burst of output data. The latency can be programmed 2, 2.5 or 3 clocks. If a Read command is registered at clock edge n, and the latency is m clocks, the data is available nominally coincident with clock edge n + m. Reserved states should not be used as unknown operation or incompatibility with future versions may result. 2002-05-06 Page 11 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Operating Mode The normal operating mode is selected by issuing a Mode Register Set Command with bits A7-A11 set to zero, and bits A0-A6 set to the desired values. A DLL reset is initiated by issuing a Mode Register Set command with bits A7 and A9-A11 each set to zero, bit A8 set to one, and bits A0-A6 set to the desired values. A Mode Register Set command issued to reset the DLL should always be followed by a Mode Register Set command to select normal operating mode. All other combinations of values for A7-A11 are reserved for future use and/or test modes. Test modes and reserved states should not be used as unknown operation or incompatibility with future versions may result. Required CAS Latencies CAS Latency = 2, BL = 4 CK CK Command Read NOP NOP NOP NOP NOP CL=2 DQS DQ CAS Latency = 2.5, BL = 4 CK CK Command Read NOP NOP NOP NOP NOP CL=2.5 DQS DQ Shown with nominal tAC , tDQSCK, and tDQSQ. Page 12 of 76 Don’t Care 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Extended Mode Register The Extended Mode Register controls functions beyond those controlled by the Mode Register; these additional functions include DLL enable/disable, and output drive strength selection (optional). These functions are controlled via the bits shown in the Extended Mode Register Definition. The Extended Mode Register is programmed via the Mode Register Set command (with BA0 = 1 and BA1 = 0) and retains the stored information until it is programmed again or the device loses power. The Extended Mode Register must be loaded when all banks are idle, and the controller must wait the specified time before initiating any subsequent operation. Violating either of these requirements result in unspecified operation. DLL Enable/Disable The DLL must be enabled for normal operation. DLL enable is required during power up initialization, and upon returning to normal operation after having disabled the DLL for the purpose of debug or evaluation. The DLL is automatically disabled when entering self refresh operation and is automatically re-enabled upon exit of self refresh operation. Any time the DLL is enabled, 200 clock cycles must occur before a Read command can be issued. This is the reason 200 clock cycles must occur before issuing a Read or Write command upon exit of self refresh operation. Output Drive Strength The normal drive strength for all outputs is specified to be SSTL_2, Class II. I-V curves for the normal drive strength are included in this document. In addition this design version supports a weak driver mode for lighter load and/or point-to-point environments which can be activated during mode register set. I-V curves for the weak driver mode will be included in this document later. 2002-05-06 Page 13 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Extended Mode Register Definition BA1 0* BA0 A11 A10 A9 A8 A7 A6 A5 A4 A3 Operating Mode 1* A2 A1 A0 Address Bus 0 DS DLL Extended Mode Register Drive Strength An - A3 A2 - A0 Operating Mode 0 Valid Normal Operation − − All other states Reserved A1 Drive Strength 0 Normal 1 Weak A2 0 must be set to 0 * BA0 and BA1 must be 1, 0 to select the Extended Mode Register (vs. the base Mode Register) Page 14 of 76 A0 DLL 0 Enable 1 Disable 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Commands Deselect The Deselect function prevents new commands from being executed by the DDR SDRAM. The DDR SDRAM is effectively deselected. Operations already in progress are not affected. No Operation (NOP) The No Operation (NOP) command is used to perform a NOP to a DDR SDRAM. This prevents unwanted commands from being registered during idle or wait states. Operations already in progress are not affected. Mode Register Set The mode registers are loaded via inputs A0-A11, BA0 and BA1. See mode register descriptions in the Register Definition section. The Mode Register Set command can only be issued when all banks are idle and no bursts are in progress. A subsequent executable command cannot be issued until tMRD is met. Active The Active command is used to open (or activate) a row in a particular bank for a subsequent access. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-A11 selects the row. This row remains active (or open) for accesses until a Precharge (or Read or Write with Auto Precharge) is issued to that bank. A Precharge (or Read or Write with Auto Precharge) command must be issued and completed before opening a different row in the same bank. Read The Read command is used to initiate a burst read access to an active (open) row. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-Ai, Aj (where [i = 8, j = don’t care] for x16, [i = 9, j = don’t care] for x8 and [i = 9, j = 11] for x4) selects the starting column location. The value on input A10 determines whether or not Auto Precharge is used. If Auto Precharge is selected, the row being accessed is precharged at the end of the Read burst; if Auto Precharge is not selected, the row remains open for subsequent accesses. Write The Write command is used to initiate a burst write access to an active (open) row. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-Ai, Aj (where [i = 9, j = don’t care] for x8; where [i = 9, j = 11] for x4) selects the starting column location. The value on input A10 determines whether or not Auto Precharge is used. If Auto Precharge is selected, the row being accessed is precharged at the end of the Write burst; if Auto Precharge is not selected, the row remains open for subsequent accesses. Input data appearing on the DQs is written to the memory array subject to the DM input logic level appearing coincident with the data. If a given DM signal is registered low, the corresponding data is written to memory; if the DM signal is registered high, the corresponding data inputs are ignored, and a Write is not executed to that byte/column location. Precharge The Precharge command is used to deactivate (close) the open row in a particular bank or the open row(s) in all banks. The bank(s) will be available for a subsequent row access a specified time (t RP) after the Precharge command is issued. Input A10 determines whether one or all banks are to be precharged, and in the case where only one bank is to be precharged, inputs BA0, BA1 select the bank. Otherwise BA0, BA1 are treated 2002-05-06 Page 15 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM as “Don’t Care.” Once a bank has been precharged, it is in the idle state and must be activated prior to any Read or Write commands being issued to that bank. A precharge command is treated as a NOP if there is no open row in that bank, or if the previously open row is already in the process of precharging. Auto Precharge Auto Precharge is a feature which performs the same individual-bank precharge functions described above, but without requiring an explicit command. This is accomplished by using A10 to enable Auto Precharge in conjunction with a specific Read or Write command. A precharge of the bank/row that is addressed with the Read or Write command is automatically performed upon completion of the Read or Write burst. Auto Precharge is nonpersistent in that it is either enabled or disabled for each individual Read or Write command. Auto Precharge ensures that the precharge is initiated at the earliest valid stage within a burst. The user must not issue another command to the same bank until the precharge (tRP) is completed. This is determined as if an explicit Precharge command was issued at the earliest possible time, as described for each burst type in the Operation section of this data sheet. Burst Terminate The Burst Terminate command is used to truncate read bursts (with Auto Precharge disabled). The most recently registered Read command prior to the Burst Terminate command is truncated, as shown in the Operation section of this data sheet. Auto Refresh Auto Refresh is used during normal operation of the DDR SDRAM and is analogous to CAS Before RAS (CBR) Refresh in previous DRAM types. This command is nonpersistent, so it must be issued each time a refresh is required. The refresh addressing is generated by the internal refresh controller. This makes the address bits “Don’t Care” during an Auto Refresh command. The 128Mb DDR SDRAM requires Auto Refresh cycles at an average periodic interval of 15.6 µs (maximum). To allow for improved efficiency in scheduling and switching between tasks, some flexibility in the absolute refresh interval is provided. A maximum of eight Auto Refresh commands can be posted in the system, meaning that the maximum absolute interval between any Auto Refresh command and the next Auto Refresh command is 9 * 15.6 µs. This maximum absolute interval is short enough to allow for DLL updates internal to the DDR SDRAM to be restricted to Auto Refresh cycles, without allowing too much drift in tAC between updates. Self Refresh The Self Refresh command can be used to retain data in the DDR SDRAM, even if the rest of the system is powered down. When in the self refresh mode, the DDR SDRAM retains data without external clocking. The Self Refresh command is initiated as an Auto Refresh command coincident with CKE transitioning low. The DLL is automatically disabled upon entering Self Refresh, and is automatically enabled upon exiting Self Refresh (200 clock cycles must then occur before a Read command can be issued). Input signals except CKE (low) are “Don’t Care” during Self Refresh operation. The procedure for exiting self refresh requires a sequence of commands. CK (and CK) must be stable prior to CKE returning high. Once CKE is high, the SDRAM must have NOP commands issued for tXSNR because time is required for the completion of any internal refresh in progress. A simple algorithm for meeting both refresh and DLL requirements is to apply NOPs for 200 clock cycles before applying any other command. Page 16 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Truth Table 1a: Commands Name (Function) CS RAS CAS WE Address MNE Notes Deselect (Nop) H X X X X NOP 1, 9 No Operation (Nop) L H H H X NOP 1, 9 Active (Select Bank And Activate Row) L L H H Bank/Row ACT 1, 3 Read (Select Bank And Column, And Start Read Burst) L H L H Bank/Col Read 1, 4 Write (Select Bank And Column, And Start Write Burst) L H L L Bank/Col Write 1, 4 Burst Terminate L H H L X BST 1, 8 Precharge (Deactivate Row In Bank Or Banks) L L H L Code PRE 1, 5 Auto Refresh Or Self Refresh (Enter Self Refresh Mode) L L L H X AR / SR 1, 6, 7 Mode Register Set L L L L Op-Code MRS 1, 2 1. CKE is HIGH for all commands shown except Self Refresh. 2. BA0, BA1 select either the Base or the Extended Mode Register (BA0 = 0, BA1 = 0 selects Mode Register; BA0 = 1, BA1 = 0 selects Extended Mode Register; other combinations of BA0-BA1 are reserved; A0-A11 provide the op-code to be written to the selected Mode Register.) 3. BA0-BA1 provide bank address and A0-A11 provide row address. 4. BA0, BA1 provide bank address; A0-Ai provide column address (where i = 8 for x16, i = 9 for x8 and 9, 11 for x4); A10 HIGH enables the Auto Precharge feature (nonpersistent), A10 LOW disables the Auto Precharge feature. 5. A10 LOW: BA0, BA1 determine which bank is precharged. A10 HIGH: all banks are precharged and BA0, BA1 are “Don’t Care.” 6. This command is AUTO REFRESH if CKE is HIGH; Self Refresh if CKE is LOW. 7. Internal refresh counter controls row and bank addressing; all inputs and I/Os are “Don’t Care” except for CKE. 8. Applies only to read bursts with Auto Precharge disabled; this command is undefined (and should not be used) for read bursts with Auto Precharge enabled or for write bursts 9. Deselect and NOP are functionally interchangeable. Truth Table 1b: DM Operation Name (Function) DM DQs Notes Write Enable L Valid 1 Write Inhibit H X 1 1. Used to mask write data; provided coincident with the corresponding data. 2002-05-06 Page 17 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Operations Bank/Row Activation Before any Read or Write commands can be issued to a bank within the DDR SDRAM, a row in that bank must be “opened” (activated). This is accomplished via the Active command and addresses A0-A11, BA0 and BA1 (see Activating a Specific Row in a Specific Bank), which decode and select both the bank and the row to be activated. After opening a row (issuing an Active command), a Read or Write command may be issued to that row, subject to the tRCD specification. A subsequent Active command to a different row in the same bank can only be issued after the previous active row has been “closed” (precharged). The minimum time interval between successive Active commands to the same bank is defined by tRC. A subsequent Active command to another bank can be issued while the first bank is being accessed, which results in a reduction of total row-access overhead. The minimum time interval between successive Active commands to different banks is defined by tRRD. Activating a Specific Row in a Specific Bank CK CK CKE HIGH CS RAS CAS WE Page 18 of 76 A0-A11 RA BA0, BA1 BA RA = row address. BA = bank address. Don’t Care 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM tRCD and tRRD Definition CK CK NOP ACT A0-A11 ROW ROW COL BA0, BA1 BA x BA y BA y tRRD ACT NOP NOP RD/WR Command NOP NOP tRCD Don’t Care Reads Subsequent to programming the mode register with CAS latency, burst type, and burst length, Read bursts are initiated with a Read command, as shown on Read Command on page 20. The starting column and bank addresses are provided with the Read command and Auto Precharge is either enabled or disabled for that burst access. If Auto Precharge is enabled, the row that is accessed starts precharge at the completion of the burst, provided tRAS has been satisfied. For the generic Read commands used in the following illustrations, Auto Precharge is disabled. During Read bursts, the valid data-out element from the starting column address is available following the CAS latency after the Read command. Each subsequent data-out element is valid nominally at the next positive or negative clock edge (i.e. at the next crossing of CK and CK). Page Read Burst: CAS Latencies (Burst Length = 4) on page 21 shows general timing for each supported CAS latency setting. DQS is driven by the DDR SDRAM along with output data. The initial low state on DQS is known as the read preamble; the low state coincident with the last data-out element is known as the read postamble. Upon completion of a burst, assuming no other commands have been initiated, the DQs goes High-Z. Data from any Read burst may be concatenated with or truncated with data from a subsequent Read command. In either case, a continuous flow of data can be maintained. The first data element from the new burst follows either the last element of a completed burst or the last desired data element of a longer burst which is being truncated. The new Read command should be issued x cycles after the first Read command, where x equals the number of desired data element pairs (pairs are required by the 2n prefetch architecture). This is shown on Consecutive Read Bursts: CAS Latencies (Burst Length = 4 or 8) on page 22. A Read command can be initiated on any clock cycle following a previous Read command. Nonconsecutive Read data is illustrated on Non-Consecutive Read Bursts: CAS Latencies (Burst Length = 4) on page 23. Full-speed Random Read Accesses: CAS Latencies (Burst Length = 2, 4 or 8) within a page (or pages) can be performed as shown on page 24. 2002-05-06 Page 19 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Read Command CK CK CKE HIGH CS RAS CAS WE x4: A0-A9, A11 x8: A0-A9 x16: A0-A8 CA EN AP A10 DIS AP BA0, BA1 BA CA = column address BA = bank address EN AP = enable Auto Precharge DIS AP = disable Auto Precharge Don’t Care Page 20 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Read Burst: CAS Latencies (Burst Length = 4) CAS Latency = 2 CK CK Command Address Read NOP NOP NOP NOP NOP BA a,COL n CL=2 DQS DOa-n DQ CAS Latency = 2.5 CK CK Command Address Read NOP NOP NOP NOP NOP BA a,COL n CL=2.5 DQS DQ DOa-n DO a-n = data out from bank a, column n. 3 subsequent elements of data out appear in the programmed order following DO a-n. Shown with nominal tAC, tDQSCK, and tDQSQ. 2002-05-06 Don’t Care Page 21 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Consecutive Read Bursts: CAS Latencies (Burst Length = 4 or 8) CAS Latency = 2 CK CK Command Address Read NOP Read BAa, COL n NOP NOP NOP BAa, COL b CL=2 DQS DQ DOa-b DOa-n CAS Latency = 2.5 CK CK Command Address Read NOP Read BAa, COL n NOP NOP NOP BAa,COL b CL=2.5 DQS DQ DOa- n DO a-n (or a-b) = data out from bank a, column n (or bank a, column b). When burst length = 4, the bursts are concatenated. When burst length = 8, the second burst interrupts the first. 3 subsequent elements of data out appear in the programmed order following DO a-n. 3 (or 7) subsequent elements of data out appear in the programmed order following DO a-b. Shown with nominal tAC , tDQSCK, and tDQSQ. Page 22 of 76 DOa- b Don’t Care 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Non-Consecutive Read Bursts: CAS Latencies (Burst Length = 4) CAS Latency = 2 CK CK Read Command NOP NOP Read BAa, COL n Address NOP NOP BAa, COL b CL=2 DQS DO a-n DQ DOa- b CAS Latency = 2.5 CK CK Command Address Read NOP NOP BAa, COL n Read NOP NOP NOP BAa, COL b CL=2.5 DQS DQ DO a-n DO a-n (or a-b) = data out from bank a, column n (or bank a, column b). 3 subsequent elements of data out appear in the programmed order following DO a-n (and following DO a-b). Shown with nominal tAC, tDQSCK, and tDQSQ. 2002-05-06 DOa- b Don’t Care Page 23 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Random Read Accesses: CAS Latencies (Burst Length = 2, 4 or 8) CAS Latency = 2 CK CK Command Address Read Read Read Read BAa, COL n BAa, COL x BAa, COL b BAa, COL g NOP NOP CL=2 DQS DQ DOa-n DOa-n' DOa-x DOa-x' DOa-b DOa-b’ DOa-g CAS Latency = 2.5 CK CK Command Address Read Read Read Read BAa, COL n BAa, COL x BAa, COL b BAa, COL g NOP NOP CL=2.5 DQS DQ DOa-n DO a-n, etc. = data out from bank a, column n etc. n' etc. = odd or even complement of n, etc. (i.e., column address LSB inverted). Reads are to active rows in any banks. Shown with nominal tAC , tDQSCK, and tDQSQ. Page 24 of 76 DOa-n' DOa-x DOa-x' DOa-b DOa-b’ Don’t Care 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Data from any Read burst may be truncated with a Burst Terminate command, as shown on Terminating a Read Burst: CAS Latencies (Burst Length = 8) on page 26. The Burst Terminate latency is equal to the read (CAS) latency, i.e. the Burst Terminate command should be issued x cycles after the Read command, where x equals the number of desired data element pairs. Data from any Read burst must be completed or truncated before a subsequent Write command can be issued. If truncation is necessary, the Burst Terminate command must be used, as shown on Read to Write: CAS Latencies (Burst Length = 4 or 8) on page 27. The example is shown for tDQSS(min). The tDQSS(max) case, not shown here, has a longer bus idle time. t DQSS(min) and tDQSS(max) are defined in the section on Writes. A Read burst may be followed by, or truncated with, a Precharge command to the same bank (provided that Auto Precharge was not activated). The Precharge command should be issued x cycles after the Read command, where x equals the number of desired data element pairs (pairs are required by the 2n prefetch architecture). This is shown on Read to Precharge: CAS Latencies (Burst Length = 4 or 8) on page 28 for Read latencies of 2 and 2.5. Following the Precharge command, a subsequent command to the same bank cannot be issued until tRP is met. Note that part of the row precharge time is hidden during the access of the last data elements. In the case of a Read being executed to completion, a Precharge command issued at the optimum time (as described above) provides the same operation that would result from the same Read burst with Auto Precharge enabled. The disadvantage of the Precharge command is that it requires that the command and address busses be available at the appropriate time to issue the command. The advantage of the Precharge command is that it can be used to truncate bursts. 2002-05-06 Page 25 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Terminating a Read Burst: CAS Latencies (Burst Length = 8) CAS Latency = 2 CK CK Command Address Read NOP BST NOP NOP NOP BAa, COL n CL=2 DQS DQ DOa-n No further output data after this point. DQS tristated. CAS Latency = 2.5 CK CK Command Address Read NOP BST NOP NOP NOP BAa, COL n CL=2.5 DQS DQ DOa-n No further output data after this point. DQS tristated. DO a-n = data out from bank a, column n. Cases shown are bursts of 8 terminated after 4 data elements. 3 subsequent elements of data out appear in the programmed order following DO a-n. Shown with nominal tAC, tDQSCK, and tDQSQ. Page 26 of 76 Don’t Care 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Read to Write: CAS Latencies (Burst Length = 4 or 8) CAS Latency = 2 CK CK Command Address Read BST NOP BAa, COL n Write NOP NOP BAa, COL b CL=2 tDQSS (min) DQS DQ DI a-b DOa-n DM CAS Latency = 2.5 CK CK Command Address Read BST NOP NOP BAa, COL n Write NOP BAa, COL b CL=2.5 tDQSS (min) DQS DQ DOa-n Dla-b DM DO a-n = data out from bank a, column n .DI a-b = data in to bank a, column b 1 subsequent elements of data out appear in the programmed order following DO a-n. Data In elements are applied following Dl a-b in the programmed order, according to burst length. Shown with nominal tAC, tDQSCK, and tDQSQ. 2002-05-06 Don’t Care Page 27 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Read to Precharge: CAS Latencies (Burst Length = 4 or 8) CAS Latency = 2 CK CK Command Read NOP PRE NOP NOP ACT tRP Address BA a, COL n BA a or all BA a, ROW CL=2 DQS DOa-n DQ CAS Latency = 2.5 CK CK Command Read NOP PRE NOP NOP ACT tRP Address BA a or all BA a, COL n BA a, ROW CL=2.5 DQS DQ DOa-n DO a-n = data out from bank a, column n. Cases shown are either uninterrupted bursts of 4 or interrupted bursts of 8. 3 subsequent elements of data out appear in the programmed order following DO a-n. Shown with nominal tAC , tDQSCK, and tDQSQ . Page 28 of 76 Don’t Care 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Writes Write bursts are initiated with a Write command, as shown on Write Command on page 30. The starting column and bank addresses are provided with the Write command, and Auto Precharge is either enabled or disabled for that access. If Auto Precharge is enabled, the row being accessed is precharged at the completion of the burst. For the generic Write commands used in the following illustrations, Auto Precharge is disabled. During Write bursts, the first valid data-in element is registered on the first rising edge of DQS following the write command, and subsequent data elements are registered on successive edges of DQS. The Low state on DQS between the Write command and the first rising edge is known as the write preamble; the Low state on DQS following the last data-in element is known as the write postamble. The time between the Write command and the first corresponding rising edge of DQS (t DQSS) is specified with a relatively wide range (from 75% to 125% of one clock cycle), so most of the Write diagrams that follow are drawn for the two extreme cases (i.e. tDQSS(min) and tDQSS(max)). Write Burst (Burst Length = 4) on page 31 shows the two extremes of tDQSS for a burst of four. Upon completion of a burst, assuming no other commands have been initiated, the DQs enters High-Z and any additional input data is ignored. Data for any Write burst may be concatenated with or truncated with a subsequent Write command. In either case, a continuous flow of input data can be maintained. The new Write command can be issued on any positive edge of clock following the previous Write command. The first data element from the new burst is applied after either the last element of a completed burst or the last desired data element of a longer burst which is being truncated. The new Write command should be issued x cycles after the first Write command, where x equals the number of desired data element pairs (pairs are required by the 2n prefetch architecture). Write to Write (Burst Length = 4) on page 32 shows concatenated bursts of 4. An example of non-consecutive Writes is shown on Write to Write: Max DQSS, Non-Consecutive (Burst Length = 4) on page 33. Full-speed random write accesses within a page or pages can be performed as shown on Random Write Cycles (Burst Length = 2, 4 or 8) on page 34. Data for any Write burst may be followed by a subsequent Read command. To follow a Write without truncating the write burst, tWTR (Write to Read) should be met as shown on Write to Read: NonInterrupting (CAS Latency = 2; Burst Length = 4) on page 35. Data for any Write burst may be truncated by a subsequent Read command, as shown in the figures on Write to Read: Interrupting (CAS Latency = 2; Burst Length = 8) on page 36 to Write to Read: Nominal DQSS, Interrupting (CAS Latency = 2; Burst Length = 8) on page 38. Note that only the data-in pairs that are registered prior to the t WTR period are written to the internal array, and any subsequent data-in must be masked with DM, as shown in the diagrams noted previously. Data for any Write burst may be followed by a subsequent Precharge command. To follow a Write without truncating the write burst, tWR should be met as shown on Write to Precharge: Non-Interrupting (Burst Length = 4) on page 39. Data for any Write burst may be truncated by a subsequent Precharge command, as shown in the figures on Write to Precharge: Interrupting (Burst Length = 4 or 8) on page 40 to Write to Precharge: Nominal DQSS (2 bit Write), Interrupting (Burst Length = 4 or 8) on page 42. Note that only the data-in pairs that are registered prior to the t WR period are written to the internal array, and any subsequent data in should be masked with DM. Following the Precharge command, a subsequent command to the same bank cannot be issued until tRP is met. In the case of a Write burst being executed to completion, a Precharge command issued at the optimum time (as described above) provides the same operation that would result from the same burst with Auto Precharge. The disadvantage of the Precharge command is that it requires that the command and address busses be available at the appropriate time to issue the command. The advantage of the Precharge command is that it can be used to truncate bursts. 2002-05-06 Page 29 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Write Command CK CK CKE HIGH CS RAS CAS WE x4: A0-A9, A11 x8: A0-A9 x16: A0-A8 CA EN AP A10 DIS AP BA0, BA1 BA CA = column address BA = bank address EN AP = enable Auto Precharge DIS AP = disable Auto Precharge Don’t Care Page 30 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Write Burst (Burst Length = 4) Maximum DQSS T1 T2 T3 T4 CK CK Command Address Write NOP NOP NOP BA a, COL b tDQSS (max) DQS Dla-b DQ DM Minimum DQSS T1 T2 T3 T4 CK CK Command Address Write NOP NOP NOP BA a, COL b tDQSS (min) DQS DQ Dla-b DM DI a-b = data in for bank a, column b. 3 subsequent elements of data in are applied in the programmed order following DI a-b. A non-interrupted burst is shown. A10 is Low with the Write command (Auto Precharge is disabled). Don’t Care 2002-05-06 Page 31 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Write to Write (Burst Length = 4) Maximum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Address Write NOP Write BAa, COL b NOP NOP NOP BAa, COL n tDQSS (max) DQS DI a-b DQ DI a-n DM Minimum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Address Write NOP BA, COL b Write NOP NOP NOP BA, COL n tDQSS (min) DQS DQ DI a-b DI a-n DM DI a-b = data in for bank a, column b, etc. 3 subsequent elements of data in are applied in the programmed order following DI a-b. 3 subsequent elements of data in are applied in the programmed order following DI a-n. A non-interrupted burst is shown. Each Write command may be to any bank. Page 32 of 76 Don’t Care 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Write to Write: Max DQSS, Non-Consecutive (Burst Length = 4) T1 T2 T3 T4 T5 CK CK Command Address Write NOP NOP BAa, COL b Write NOP BAa, COL n tDQSS (max) DQS DQ DI a-b DI a-n DM DI a-b, etc. = data in for bank a, column b, etc. 3 subsequent elements of data in are applied in the programmed order following DI a-b. 3 subsequent elements of data in are applied in the programmed order following DI a-n. A non-interrupted burst is shown. Each Write command may be to any bank. 2002-05-06 Don’t Care Page 33 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Random Write Cycles (Burst Length = 2, 4 or 8) Maximum DQSS T1 T2 T3 T4 T5 CK CK Command Address Write Write BAa, COL b Write BAa, COL x Write BAa, COL n Write BAa, COL a BAa, COL g tDQSS (max) DQS DQ DI a-b DI a-b’ DI a-x DI a-x’ DI a-n DI a-n’ DI a-a DI a-a’ DM Minimum DQSS T1 T2 T3 T4 T5 CK CK Command Address Write Write BAa, COL b Write BAa, COL x Write BAa, COL n Write BAa, COL a BAa, COL g tDQSS (min) DQS DQ DI a-b DI a-b’ DI a-x DI a-x’ DI a-n DI a-n’ DI a-a DI a-a’ DI a-g DM DI a-b, etc. = data in for bank a, column b, etc. b', etc. = odd or even complement of b, etc. (i.e., column address LSB inverted). Each Write command may be to any bank. Page 34 of 76 Don’t Care 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Write to Read: Non-Interrupting (CAS Latency = 2; Burst Length = 4) Maximum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL b BAa, COL n CL = 2 tDQSS (max) DQS DQ DI a-b DM Minimum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL n BAa, COL b tDQSS (min) CL = 2 DQS DQ DI a-b DM DI a-b = data in for bank a, column b. 3 subsequent elements of data in are applied in the programmed order following DI a-b. A non-interrupted burst is shown. tWTR is referenced from the first positive CK edge after the last data in pair. A10 is Low with the Write command (Auto Precharge is disabled). The Read and Write commands may be to any bank. 2002-05-06 Don’t Care Page 35 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Write to Read: Interrupting (CAS Latency = 2; Burst Length = 8) Maximum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL n BAa, COL b CL = 2 tDQSS (max) DQS DQ DIa- b 1 DM 1 Minimum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL n BAa, COL b CL = 2 tDQSS (min) DQS DQ DI a-b DM 1 1 DI a-b = data in for bank a, column b. An interrupted burst is shown, 4 data elements are written. 3 subsequent elements of data in are applied in the programmed order following DI a-b. tWTR is referenced from the first positive CK edge after the last data in pair. The Read command masks the last 2 data elements in the burst. A10 is Low with the Write command (Auto Precharge is disabled). The Read and Write commands are not necessarily to the same bank. 1 = These bits are incorrectly written into the memory array if DM is low. Page 36 of 76 Don’t Care 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Write to Read: Minimum DQSS, Odd Number of Data (3 bit Write), Interrupting (CAS Latency = 2; Burst Length = 8) T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL n BAa, COL b CL = 2 tDQSS (min) DQS DQ DM DI a-b 1 2 2 DI a-b = data in for bank a, column b. An interrupted burst is shown, 3 data elements are written. 2 subsequent elements of data in are applied in the programmed order following DI a-b. tWTR is referenced from the first positive CK edge after the last desired data in pair (not the last desired data in element) The Read command masks the last 2 data elements in the burst. A10 is Low with the Write command (Auto Precharge is disabled). The Read and Write commands are not necessarily to the same bank. 1 = This bit is correctly written into the memory array if DM is low. Don’t Care 2 = These bits are incorrectly written into the memory array if DM is low. 2002-05-06 Page 37 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Write to Read: Nominal DQSS, Interrupting (CAS Latency = 2; Burst Length = 8) T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL n BAa, COL b CL = 2 tDQSS (nom) DQS DQ DI a-b DM 1 1 DI a-b = data in for bank a, column b. An interrupted burst is shown, 4 data elements are written. 3 subsequent elements of data in are applied in the programmed order following DI a-b. tWTR is referenced from the first positive CK edge after the last desired data in pair. The Read command masks the last 2 data elements in the burst. A10 is Low with the Write command (Auto Precharge is disabled). The Read and Write commands are not necessarily to the same bank. 1 = These bits are incorrectly written into the memory array if DM is low. Page 38 of 76 Don’t Care 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Write to Precharge: Non-Interrupting (Burst Length = 4) Maximum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP NOP PRE tWR Address BA (a or all) BA a, COL b tRP tDQSS (max) DQS DQ DI a-b DM Minimum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP NOP PRE tWR Address BA (a or all) BA a, COL b tDQSS (min) tRP DQS DQ DI a-b DM DI a-b = data in for bank a, column b. 3 subsequent elements of data in are applied in the programmed order following DI a-b. A non-interrupted burst is shown. tWR is referenced from the first positive CK edge after the last data in pair. A10 is Low with the Write command (Auto Precharge is disabled). 2002-05-06 Don’t Care Page 39 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Write to Precharge: Interrupting (Burst Length = 4 or 8) Maximum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP PRE NOP tWR Address BA (a or all) BA a, COL b tDQSS (max) tRP 2 DQS DI a-b DQ 3 DM 1 3 1 Minimum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP PRE NOP tWR Address BA a, COL b BA (a or all) tDQSS (min) tRP 2 DQS DQ DM DI a-b 3 3 1 1 DI a-b = data in for bank a, column b. An interrupted burst is shown, 2 data elements are written. 1 subsequent element of data in is applied in the programmed order following DI a-b. tWR is referenced from the first positive CK edge after the last desired data in pair. The Precharge command masks the last 2 data elements in the burst, for burst length = 8. A10 is Low with the Write command (Auto Precharge is disabled). 1 = Can be don't care for programmed burst length of 4. 2 = For programmed burst length of 4, DQS becomes don't care at this point. 3 = These bits are incorrectly written into the memory array if DM is low. Page 40 of 76 Don’t Care 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Write to Precharge: Minimum DQSS, Odd Number of Data (1 bit Write), Interrupting (Burst Length = 4 or 8) T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP PRE NOP tWR Address BA a, COL b BA (a or all) tDQSS (min) tRP 2 DQS DQ DM DI a-b 3 4 4 1 1 DI a-b = data in for bank a, column b. An interrupted burst is shown, 1 data element is written. tWR is referenced from the first positive CK edge after the last desired data in pair. The Precharge command masks the last 2 data elements in the burst. A10 is Low with the Write command (Auto Precharge is disabled). 1 = Can be don't care for programmed burst length of 4. 2 = For programmed burst length of 4, DQS becomes don't care at this point. 3 = This bit is correctly written into the memory array if DM is low. 4 = These bits are incorrectly written into the memory array if DM is low. 2002-05-06 Don’t Care Page 41 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Write to Precharge: Nominal DQSS (2 bit Write), Interrupting (Burst Length = 4 or 8) T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP PRE NOP tWR Address BA (a or all) BA a, COL b tDQSS (nom) tRP 2 DQS DQ DM DI a-b 3 3 1 1 DI a-b = Data In for bank a, column b. An interrupted burst is shown, 2 data elements are written. 1 subsequent element of data in is applied in the programmed order following DI a-b. tWR is referenced from the first positive CK edge after the last desired data in pair. The Precharge command masks the last 2 data elements in the burst. A10 is Low with the Write command (Auto Precharge is disabled). 1 = Can be don't care for programmed burst length of 4. 2 = For programmed burst length of 4, DQS becomes don't care at this point. 3 = These bits are incorrectly written into the memory array if DM is low. Page 42 of 76 Don’t Care 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Precharge Command CK CK CKE HIGH CS RAS CAS WE A0-A9, A11 All Banks A10 BA0, BA1 One Bank BA BA = bank address (if A10 is Low, otherwise Don’t Care). Don’t Care Precharge The Precharge command is used to deactivate the open row in a particular bank or the open row in all banks. The bank(s) will be available for a subsequent row access some specified time (tRP) after the Precharge command is issued. Input A10 determines whether one or all banks are to be precharged, and in the case where only one bank is to be precharged, inputs BA0, BA1 select the bank. When all banks are to be precharged, inputs BA0, BA1 are treated as “Don’t Care.” Once a bank has been precharged, it is in the idle state and must be activated prior to any Read or Write commands being issued to that bank. 2002-05-06 Page 43 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Power-Down Power-down is entered when CKE is registered LOW (no accesses can be in progress). If power-down occurs when all banks are idle, this mode is referred to as precharge power-down; if power-down occurs when there is a row active in any bank, this mode is referred to as active power-down. Entering power-down deactivates the input and output buffers, excluding CK, CK and CKE. The DLL is still running in Power Down mode, so for maximum power savings, the user has the option of disabling the DLL prior to entering Powerdown. In that case, the DLL must be enabled after exiting power-down, and 200 clock cycles must occur before a Read command can be issued. In power-down mode, CKE Low and a stable clock signal must be maintained at the inputs of the DDR SDRAM, and all other input signals are “Don’t Care”. However, powerdown duration is limited by the refresh requirements of the device, so in most applications, the self refresh mode is preferred over the DLL-disabled power-down mode. The power-down state is synchronously exited when CKE is registered HIGH (along with a Nop or Deselect command). A valid, executable command may be applied one clock cycle later. Power Down CK CK tIS CKE Command VALID NOP No column access in progress Enter Power Down mode (Burst Read or Write operation must not be in progress) Page 44 of 76 tIS NOP VALID Exit power down mode Don’t Care 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Truth Table 2: Clock Enable (CKE) 1. 2. 3. 4. CKEn is the logic state of CKE at clock edge n: CKE n-1 was the state of CKE at the previous clock edge. Current state is the state of the DDR SDRAM immediately prior to clock edge n. COMMAND n is the command registered at clock edge n, and ACTION n is a result of COMMAND n. All states and sequences not shown are illegal or reserved. CKE n-1 CKEn Current State Previous Cycle Current Cycle Command n Self Refresh L L X Self Refresh L H Deselect or NOP Power Down L L X Power Down L H Deselect or NOP Exit Power-Down All Banks Idle H L Deselect or NOP Precharge Power-Down Entry All Banks Idle H L AUTO REFRESH Self Refresh Entry Bank(s) Active H L Deselect or NOP Active Power-Down Entry H H See “Truth Table 3: Current State Bank n - Command to Bank n (Same Bank)” on page 46 Action n Notes Maintain Self-Refresh Exit Self-Refresh 1 Maintain Power-Down 1. Deselect or NOP commands should be issued on any clock edges occurring during the Self Refresh Exit (tXSNR) period. A minimum of 200 clock cycles are needed before applying a read command to allow the DLL to lock to the input clock. 2002-05-06 Page 45 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Truth Table 3: Current State Bank n - Command to Bank n (Same Bank) Current State Any Idle Row Active Read (Auto Precharge Disabled) Write (Auto Precharge Disabled) CS RAS CAS WE Command Action Notes H X X X Deselect NOP. Continue previous operation 1-6 L H H H No Operation NOP. Continue previous operation 1-6 L L H H Active Select and activate row 1-6 L L L H AUTO REFRESH L L L L MODE REGISTER SET L H L H Read Select column and start Read burst 1-6, 10 L H L L Write Select column and start Write burst 1-6, 10 L L H L Precharge 1-7 1-7 Deactivate row in bank(s) Select column and start new Read burst 1-6, 8 L H L H Read L L H L Precharge L H H L BURST TERMINATE L H L H Read Select column and start Read burst 1-6, 10, 11 L H L L Write Select column and start Write burst 1-6, 10 L L H L Precharge Truncate Read burst, start Precharge BURST TERMINATE Truncate Write burst, start Precharge 1-6, 10 1-6, 8 1-6, 9 1-6, 8, 11 1. This table applies when CKE n-1 was HIGH and CKE n is HIGH (see Truth Table 2: Clock Enable (CKE) and after tXSNR / tXSRD has been met (if the previous state was self refresh). 2. This table is bank-specific, except where noted, i.e., the current state is for a specific bank and the commands shown are those allowed to be issued to that bank when in that state. Exceptions are covered in the notes below. 3. Current state definitions: Idle: The bank has been precharged, and tRP has been met. Row Active: A row in the bank has been activated, and tRCD has been met. No data bursts/accesses and no register accesses are in progress. Read: A Read burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. Write: A Write burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. 4. The following states must not be interrupted by a command issued to the same bank. Precharging:Starts with registration of a Precharge command and ends when tRP is met. Once tRP is met, the bank is in the idle state. Row Activating:Starts with registration of an Active command and ends when tRCD is met. Once tRCD is met, the bank is in the “row active” state. Read w/Auto Precharge Enabled: Starts with registration of a Read command with Auto Precharge enabled and ends when tRP has been met. Once tRP is met, the bank is in the idle state. Write w/Auto Precharge Enabled: Starts with registration of a Write command with Auto Precharge enabled and ends when tRP has been met. Once tRP is met, the bank is in the idle state. Deselect or NOP commands, or allowable commands to the other bank should be issued on any clock edge occurring during these states. Allowable commands to the other bank are determined by its current state and according to Truth Table 4. 5. The following states must not be interrupted by any executable command; Deselect or NOP commands must be applied on each positive clock edge during these states. Refreshing: Starts with registration of an Auto Refresh command and ends when tRFC is met. Once tRFC is met, the DDR SDRAM is in the “all banks idle” state. Accessing Mode Register: Starts with registration of a Mode Register Set command and ends when tMRD has been met. Once tMRD is met, the DDR SDRAM is in the “all banks idle” state. Precharging All: Starts with registration of a Precharge All command and ends when tRP is met. Once tRP is met, all banks is in the idle state. 6. All states and sequences not shown are illegal or reserved. 7. Not bank-specific; requires that all banks are idle. 8. May or may not be bank-specific; if all/any banks are to be precharged, all/any must be in a valid state for precharging. 9. Not bank-specific; BURST TERMINATE affects the most recent Read burst, regardless of bank. 10. Reads or Writes listed in the Command/Action column include Reads or Writes with Auto Precharge enabled and Reads or Writes with Auto Precharge disabled. 11. Requires appropriate DM masking. Page 46 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Truth Table 4: Current State Bank n - Command to Bank m (Different bank) Current State CS RAS CAS WE Command H X X X Deselect NOP/continue previous operation 1-6 L H H H No Operation NOP/continue previous operation 1-6 Idle X X X X Any Command Otherwise Allowed to Bank m L L H H Active Select and activate row 1-6 Row Activating, Active, or Precharging L H L H Read Select column and start Read burst 1-7 L H L L Write Select column and start Write burst L L H L Precharge L L H H Active Select and activate row 1-6 L H L H Read Select column and start new Read burst 1-7 1-6 Any Read (Auto Precharge Disabled) Write (Auto Precharge Disabled) Read (With Auto Precharge) Write (With Auto Precharge) Action Notes 1-6 1-7 1-6 L L H L Precharge L L H H Active Select and activate row 1-6 L H L H Read Select column and start Read burst 1-8 L H L L Write Select column and start new Write burst 1-7 L L H L Precharge L L H H Active Select and activate row 1-6 L H L H Read Select column and start new Read burst L H L L Write Select column and start Write burst L L H L Precharge L L H H Active Select and activate row L H L H Read Select column and start Read burst 1-7,10 L H L L Write Select column and start new Write burst 1-7,10 L L H L Precharge 1-6 1-7,10 1-7,9,10 1-6 1-6 1-6 1. This table applies when CKE n-1 was HIGH and CKE n is HIGH (see Truth Table 2: Clock Enable (CKE) and after tXSNR / tXSRD has been met (if the previous state was self refresh). 2. This table describes alternate bank operation, except where noted, i.e., the current state is for bank n and the commands shown are those allowed to be issued to bank m (assuming that bank m is in such a state that the given command is allowable). Exceptions are covered in the notes below. 3. Current state definitions: Idle: The bank has been precharged, and tRP has been met. Row Active: A row in the bank has been activated, and tRCD has been met. No data bursts/accesses and no register accesses are in progress. Read: A Read burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. Write: A Write burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. Read with Auto Precharge Enabled: See note 10. Write with Auto Precharge Enabled: See note 10. 4. AUTO REFRESH and Mode Register Set commands may only be issued when all banks are idle. 5. A BURST TERMINATE command cannot be issued to another bank; it applies to the bank represented by the current state only. 6. All states and sequences not shown are illegal or reserved. 7. Reads or Writes listed in the Command/Action column include Reads or Writes with Auto Precharge enabled and Reads or Writes with Auto Precharge disabled. 8. Requires appropriate DM masking. 9. A Write command may be applied after the completion of data output. 10. Concurrent Auto Precharge: This device supports “Concurrent Auto Precharge”. When a read with auto precharge or a write with auto precharge is enabled any command may follow to the other banks as long as that command does not interrupt the read or write data transfer and all other limitations apply (e.g. contention between READ data and WRITE data must be avoided). The mimimum delay from a read or write command with auto precharge enable, to a command to a different banks is summarized in table 4a. 2002-05-06 Page 47 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Truth Table 5: Concurrent Auto Precharge From Command WRITE w/AP Minimum Delay with Concurrent Auto Precharge Support Units Read or Read w/AP 1 + (BL/2) + tWTR tCK Write ot Write w/AP BL/2 tCK 1 tCK Read or Read w/AP BL/2 tCK Write or Write w/AP CL (rounded up)+ BL/2 tCK 1 tCK To Command (different bank) Precharge or Activate Read w/AP Precharge or Activate Page 48 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Simplified State Diagram Power Applied Power On Self Refresh Precharge PREALL REFS REFSX MRS EMRS MRS Auto Refresh REFA Idle CKEL CKEH Active Power Down ACT Precharge Power Down CKEH CKEL Burst Stop Row Active Write Write A Write Read Read A Read Read Read A Write A Read A PRE Write A PRE PRE PRE Read A Precharge PREALL Automatic Sequence Command Sequence PREALL = Precharge All Banks MRS = Mode Register Set EMRS = Extended Mode Register Set REFS = Enter Self Refresh REFSX = Exit Self Refresh REFA = Auto Refresh 2002-05-06 CKEL = Enter Power Down CKEH = Exit Power Down ACT = Active Write A = Write with Autoprecharge Read A = Read with Autoprecharge PRE = Precharge Page 49 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Operating Conditions Absolute Maximum Ratings Symbol VIN , VOUT VIN VDD VDDQ TA TSTG PD IOUT Parameter Rating Units −0.5 to VDDQ+ 0.5 V Voltage on Inputs relative to V SS −0.5 to +3.6 V Voltage on V DD supply relative to VSS −0.5 to +3.6 V Voltage on V DDQ supply relative to VSS −0.5 to +3.6 V 0 to +70 °C −55 to +150 °C Power Dissipation 1.0 W Short Circuit Output Current 50 mA Voltage on I/O pins relative to V SS Operating Temperature (Ambient) Storage Temperature (Plastic) Note: Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only, and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. Input and Output Capacitances Parameter Symbol Min. Max. Units Notes Input Capacitance: CK, CK CI1 2.0 3.0 pF 1 Delta Input Capacitance: CK, CK CdI1 - 0.25 pF 1 Input Capacitance: All other input-only pins CI2 2.0 3.0 pF 1 Delta Input Capacitance: All other input-only pins CdI2 - 0.5 pF 1 Input/Output Capacitance: DQ, DQS, DM CIO 4.0 5.0 pF 1, 2 Delta Input/Output Capacitance : DQ, DQS, DM CdIO - 0.5 pF 1 1. These values are guaranteed by design and are tested on a sample base only. VDDQ = VDD = 2.5V ± 0.2V, f = 100MHz, TA = 25°C, VOUT (DC) = VDDQ/2, VOUT (Peak to Peak) 0.2V. Unused pins are tied to groundVOUT (Peak to Peak) = 0.2V. 2. DM inputs are grouped with I/O pins reflecting the fact that they are matched in loading to DQ and DQS to facilitate trace matching at the board level. Page 50 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM DC Electrical Operating Conditions (0°C ≤ TA ≤ 70°C; VDDQ = 2.5V ± 0.2V, VDD = + 2.5V ± 0.2V) Symbol Min Max Units Notes Supply Voltage 2.3 2.7 V 1 V DDQ I/O Supply Voltage 2.3 2.7 V 1 VSS, VSSQ Supply Voltage I/O Supply Voltage 0 0 V I/O Reference Voltage 0.49 x VDDQ 0.51 x VDDQ V 1, 2 I/O Termination Voltage (System) VREF − 0.04 VREF + 0.04 V 1, 3 VIH(DC) Input High (Logic1) Voltage VREF + 0.15 VDDQ + 0.3 V 1 VIL(DC) Input Low (Logic0) Voltage − 0.3 VREF − 0.15 V 1 VIN(DC) Input Voltage Level, CK and CK Inputs − 0.3 VDDQ + 0.3 V 1 VID(DC) Input Differential Voltage, CK and CK Inputs 0.36 VDDQ + 0.6 V 1, 4 VIRatio VI-Matching Pullup Current to Pulldown Current 0.71 1.4 Input Leakage Current Any input 0V ≤ VIN ≤ VDD (All other pins not under test = 0V) −2 2 µA 1 IOZ Output Leakage Current (DQs are disabled; 0V ≤ Vout ≤ VDDQ −5 5 µA 1 IOH Output High Current, Normal Strength Driver (VOUT − 15.2 mA 1 IOL Output Low Current, Normal Strength Driver (VOUT = 0.35 V) 15.2 mA 1 VDD V REF VTT II Parameter = 1.95 V) 5 1. Inputs are not recognized as valid until VREF stabilizes. 2. VREF is expected to be equal to 0.5 VDDQ of the transmitting device, and to track variations in the DC level of the same. Peak-to-peak noise on VREF may not exceed ± 2% of the DC value. 3. VTT is not applied directly to the device. VTT is a system supply for signal termination resistors, is expected to be set equal to VREF, and must track variations in the DC level of VREF. 4. VID is the magnitude of the difference between the input level on CK and the input level on CK. 5. The ration of the pullup current to the pulldown current is specified for the same temperature and voltage, over the entire temperature and voltage range, for device drain to source voltage from 0.25 to 1.0V. For a given output, it represents the maximum difference between pullup and pulldown drivers due to process variation. 2002-05-06 Page 51 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Normal Mode Pulldown and Pullup Characteristics 1. The nominal pulldown V-I curve for DDR SDRAM devices is expected, but not guaranteed, to lie within the inner bounding lines of the V-I curve. 2. The full variation in driver pulldown current from minimum to maximum process, temperature, and voltage lie within the outer bounding lines of the V-I curve. Normal Mode Pulldown Characteristics 140 Maximum 1OUT (mA) 120 100 Nominal High 80 60 Nominal Low 40 Minimum 20 0 0 0.5 1 1.5 2 2.5 VOUT (V) 3. The nominal pullup V-I curve for DDR SDRAM devices is expected, but not guaranteed, to lie within the inner bounding lines of the V-I curve. 4. The full variation in driver pullup current from minimum to maximum process, temperature, and voltage lie within the outer bounding lines of the V-I curve. Normal Mode Pullup Characteristics 0 -20 Minimum 1OUT (mA) -40 Nominal Low -60 -80 -100 -120 -140 Nominal High -160 Maximum 0 0.5 1 1.5 VOUT (V) 2 2.5 5. The full variation in the ratio of the maximum to minimum pullup and pulldown current does not exceed 1.7, for device drain to source voltages from 0.1 to 1.0. 6. The full variation in the ratio of the nominal pullup to pulldown current should be unity ± 10%, for device drain to source voltages from 0.1 to 1.0V. Page 52 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Normal Mode Pulldown and Pullup Currents Pulldown Current (mA) Voltage (V) Nominal Low Nominal High Min Pullup Current (mA) Max Nominal Low Nominal High Min Max 0.1 6.0 6.8 4.6 9.6 −6.1 −7.6 −4.6 −10.0 0.2 12.2 13.5 9.2 18.2 −12.2 −14.5 −9.2 −20.0 0.3 18.1 20.1 13.8 26.0 −18.1 −21.2 −13.8 −29.8 0.4 24.1 26.6 18.4 33.9 −24.0 −27.7 −18.4 −38.8 0.5 29.8 33.0 23.0 41.8 −29.8 −34.1 −23.0 −46.8 0.6 34.6 39.1 27.7 49.4 −34.3 −40.5 −27.7 −54.4 0.7 39.4 44.2 32.2 56.8 −38.1 −46.9 −32.2 −61.8 0.8 43.7 49.8 36.8 63.2 −41.1 −53.1 −36.0 −69.5 0.9 47.5 55.2 39.6 69.9 −43.8 −59.4 −38.2 −77.3 1.0 51.3 60.3 42.6 76.3 −46.0 −65.5 −38.7 −85.2 1.1 54.1 65.2 44.8 82.5 −47.8 −71.6 −39.0 −93.0 1.2 56.2 69.9 46.2 88.3 −49.2 −77.6 −39.2 −100.6 1.3 57.9 74.2 47.1 93.8 −50.0 −83.6 −39.4 −108.1 1.4 59.3 78.4 47.4 99.1 −50.5 −89.7 −39.6 −115.5 1.5 60.1 82.3 47.7 103.8 −50.7 −95.5 −39.9 −123.0 1.6 60.5 85.9 48.0 108.4 −51.0 −101.3 −40.1 −130.4 1.7 61.0 89.1 48.4 112.1 −51.1 −107.1 −40.2 −136.7 1.8 61.5 92.2 48.9 115.9 −51.3 −112.4 −40.3 −144.2 1.9 62.0 95.3 49.1 119.6 −51.5 −118.7 −40.4 −150.5 2.0 62.5 97.2 49.4 123.3 −51.6 −124.0 −40.5 −156.9 2.1 62.9 99.1 49.6 126.5 −51.8 −129.3 −40.6 −163.2 2.2 63.3 100.9 49.8 129.5 −52.0 −134.6 −40.7 −169.6 2.3 63.8 101.9 49.9 132.4 −52.2 −139.9 −40.8 −176.0 2.4 64.1 102.8 50.0 135.0 −52.3 −145.2 −40.9 −181.3 2.5 64.6 103.8 50.2 137.3 −52.5 −150.5 −41.0 −187.6 2.6 64.8 104.6 50.4 139.2 -52.7 -155.3 -41.1 -192.9 2.7 65.0 105.4 50.5 140.8 -52.8 -160.1 -41.2 -198.2 Evaluation Conditions for I/O Driver Characteristics 2002-05-06 Nominal Minimum Maximum Operating Temperature 25 °C 70 °C 0 °C VDD / V DDQ 2.5V 2.3V 2.7V Process Corner typical slow-slow fast-fast Page 53 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM .. Weak Mode Pulldown and Pullup Characteristics Weak Strength Pulldown Characteristics 80 Maximum 70 60 Iout [mA] Typical high 50 Typical low 40 30 Minimum 20 10 0 0,0 0,5 1,0 1,5 2,0 2,5 Vout [V] 1. The weak pulldown V-I curve for DDR SDRAM devices is expected, but not guaranteed, to lie within the inner bounding lines of the V-I curve 2. The weak pullup V-I curve for DDR SDRAM devices is expected, but not guaranteed, to lie within the inner bounding lines of the V-I curve. 3. The full variation in driver pullup current from minimum to maximum process, temperature, and voltage lie within the outer bounding lines of the V-I curve. Weak Strength Pullup Characteristics 0,0 0,0 0,5 1,0 1,5 2,0 2,5 -10,0 Minimum -20,0 Iout [V] -30,0 Typical low -40,0 -50,0 Typical high -60,0 -70,0 Maximum -80,0 Vout [V] 4. The full variation in the ratio of the maximum to minimum pullup and pulldown current does not exceed 1.7, for device drain to source voltages from 0.1 to 1.0. 5. The full variation in the ratio of the nominal pullup to pulldown current should be unity ± 10%, for device drain to source voltages from 0.1 to 1.0V. Page 54 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Weak Strength Driver Pulldown and Pullup Currents Pulldown Current (mA) Pullup Current (mA) Voltage (V) Nominal Low Nominal High Min Max Nominal Low Nominal High Min Max 0.1 3.4 3.8 2.6 5.0 -3.5 -4.3 -2.6 -5.0 0.2 6.9 7.6 5.2 9.9 -6.9 -8.2 -5.2 -9.9 0.3 10.3 11.4 7.8 14.6 -10.3 -12.0 -7.8 -14.6 0.4 13.6 15.1 10.4 19.2 -13.6 -15.7 -10.4 -19.2 0.5 16.9 18.7 13.0 23.6 -16.9 -19.3 -13.0 -23.6 0.6 19.6 22.1 15.7 28.0 -19.4 -22.9 -15.7 -28.0 0.7 22.3 25.0 18.2 32.2 -21.5 -26.5 -18.2 -32.2 0.8 24.7 28.2 20.8 35.8 -23.3 -30.1 -20.4 -35.8 0.9 26.9 31.3 22.4 39.5 -24.8 -33.6 -21.6 -39.5 1.0 29.0 34.1 24.1 43.2 -26.0 -37.1 -21.9 -43.2 1.1 30.6 36.9 25.4 46.7 -27.1 -40.3 -22.1 -46.7 1.2 31.8 39.5 26.2 50.0 -27.8 -43.1 -22.2 -50.0 1.3 32.8 42.0 26.6 53.1 -28.3 -45.8 -22.3 -53.1 1.4 33.5 44.4 26.8 56.1 -28.6 -48.4 -22.4 -56.1 1.5 34.0 46.6 27.0 58.7 -28.7 -50.7 -22.6 -58.7 1.6 34.3 48.6 27.2 61.4 -28.9 -52.9 -22.7 -61.4 1.7 34.5 50.5 27.4 63.5 -28.9 -55.0 -22.7 -63.5 1.8 34.8 52.2 27.7 65.6 -29.0 -56.8 -22.8 -65.6 1.9 35.1 53.9 27.8 67.7 -29.2 -58.7 -22.9 -67.7 2.0 35.4 55.0 28.0 69.8 -29.2 -60.0 -22.9 -69.8 2.1 35.6 56.1 28.1 71.6 -29.3 -61.2 -23.0 -71.6 2.2 35.8 57.1 28.2 73.3 -29.5 -62.4 -23.0 -73.3 2.3 36.1 57.7 28.3 74.9 -29.5 -63.1 -23.1 -74.9 2.4 36.3 58.2 28.3 76.4 -29.6 -63.8 -23.2 -76.4 2.5 36.5 58.7 28.4 77.7 -29.7 -64.4 -23.2 -77.7 2.6 36.7 59.2 28.5 78.8 -29.8 -65.1 -23.3 -78.8 2.7 36.8 59.6 28.6 79.7 -29.9 -65.8 -23.3 -79.7 2002-05-06 Page 55 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM IDD Specification and Conditions (0 °C ≤ TA ≤ 70 °C; VDDQ = 2.5V ± 0.2V; VDD = 2.5V ± 0.2V) Symbol Notes DDR333 DDR200 DDR266 Unit Notes DDR266A DDR333 typical max typical max typical max Unit 4 Parameter/Condition Symbol DDR200 Parameter/Condition typ. Operating Current: one bank; active / precharge; tRC = tRC MIN; tCK = tCK MIN; DQ, IDD0 DM, and DQS inputs: changing per/ clock cycle; address Operating Current one bank;once active precharge; tRC = tRCand ; tCK = inputs tCK MINcontrol IDD0 inputs once changing per clock cycle; address and 65 changing everyonce two clock cycles MIN; DQ, DM, and DQS max. 65 typ. max. 85 72 85 72 90 90 typ. max. 82 105 82 105 4) mA mA 1, 2 1, 2 control inputs changing once every two clock cycles IDD1 I DD1 one active bank; active/read/precharge; Burst Operating Current: Operating Current : one bank; / read / precharge; Burst = =4;4; to the following page for detailed test conditions. Refer to the Refer previous page for detailed test conditions. 67 Precharge Power-Down Standby Current: all banks idle; power-down IDD2PPrecharge Power-Down Standby Current: all banks idle; power-down mode; CKE <=2.4 mode; CKE ≤ VIL MAX; tCK = tCK MIN IDD2P VIL MAX; tCK = tCK MIN Precharge Floating Standby Current: CS ≥ VIH MIN , all banks idle; CKE ≥ Floating 17 IDD2FPrecharge VIH MIN; Standby tCK = tCKCurrent: and inputs MIN ,address /CS >= VIHother MIN,control all banks idle; changing CKE >= VIH MIN; = Vcontrol DQ, DQS and DM. cycle, VIN REF forinputs = tCK per MINclock ,address and other changing once per clock cycle, VIN = IDD2F tCK once VREF for DQ, DQS andStandby DM. Precharge Quiet Current: CS ≥ VIH MIN, all banks idle; IDD2Q CKE ≥ VIH MIN; tCK = tCK MIN ,address and other control inputs stable at ≥ 67100 100 74 74 110110 8484 4.5 2,4 2.7 35 17 tbd. VIH MINQuiet or ≤ VStandby for>=DQ, DM. idle; /CS VIHDQS MIN, and all banks Precharge Current: IL MAX; V IN = VREF IDD2Q CKE >= VIH MIN; tCK = tCK MIN ,address and other control inputs stable at >= VIH MIN Active Power-Down Standby Current: one bank active; power-down IDD3Por <= VIL MAX; VIN = VREF for DQ, DQS and DM. 12 4,5 22 5.0 5,0 45 35 35 12 2,7 22 tbd. 35 45 45 5.5 mA 1, 2 26 58 mA 1, 2 3,0 5,5 26 58 45 15 58 19 58 mA mA mA mA 1, 2 1, 2 1, 2 1, 2 12 15 mA 15 32 12 45 15 3812 15 58 mA 1, 1, mA 22 2590 35 69 32 11045 8338 58 120 mA 1, 1, mA 22 110 102 130 mA 1, 2 190 161 205 mA 1, 2 2.5 1.9 2.5 mA 1, 2, 31, 2 tbd. tbd. tbd. mA 1, 2, 3 mode; CKE ≤ VIL MAX; tCK = tCK MIN;V IN = VREF for DQ, DQS and DM. 12 3.0 tbd. 16 15 125 mA mA 1, 1, 125 22 1, 2 Active Standby Current: one bank active; active / precharge;CS ≥ V IH <= VIL Active Power-Down Standby Current: one bank active; power-down mode; CKE MIN; CKE ≥ VIH MIN ; t RC = tRAS MAX; tCK = t CK MIN; DQ, DM, and DQS 25 MAX; tCK = tCK MIN;VIN = VREF for DQ, DQS and DM. DD3N inputs changing twice per clock cycle; address and control inputs changing IDD3P I 1235 once per clock cycle Operating Current: 2; reads; continuous burst;CKE >= onebank bankactive; active;Burst active=/ precharge;CS >= VIH MIN; Active Standby Current:one address and control inputs changing once per clock cycle; DQ and DQS IDD3N IDD4RVIH MIN; tRC = tRAS MAX; tCK = tCK MIN; DQ, DM, and DQS inputs changing twice per 54 outputs changing twice per clock cycle; CL = 2 for DDR200, and clock cycle; address and control inputs changing once per clock cycle DDR266A, CL=3 for DDR333; tCK = tCK MIN; IOUT = 0mA Operating Current: one bank active; Burst = 2; writes; continuous burst; Operating Current: one bank active; Burst = 2; reads; continuous burst; address and address and control inputs changing once per clock cycle; DQ and DQS IDD4W control inputs changing once per clock cycle; 50% of data outputs changing on every 65 inputs changing twice per clock cycle; CL = 2 for DDR200, and DDR266A, IDD4R clock edge; CL = 2 for DDR200, and DDR266A, CL=3 for DDR333; tCK = tCK MIN; IOUT CL=3 for DDR333; tCK = tCK MIN 54 95 84 90 69 110 83 120 mA 1, 2 = 0mA IDD5 Auto-Refresh Current: tRC = tRFC MIN, distributed refresh 142 Operating Current: one bank active; Burst = 2; writes; continuous burst; address and standard version 1.9 control inputs changing once per≤clock 50% of data outputs changing on every Self-Refresh Current : CKE 0.2V;cycle; external IDD6 clock edge; CL = 2 for DDR200, and DDR266A, CL=3 for DDR333; tCK = tCK MIN (standard products) clock on; t = t IDD4W CK CK MIN low power version IDD5 Auto-Refresh Current: tRC = tRFC MIN, distributed refresh IDD7 tbd. 180 2.5 65 tbd. 142 153 1.9 95 84 tbd. 180 153 110 190 102 161 Operating Current: four bank; four bank interleaving with BL=4; 164 270 221 280 235 Refer to the previous page for detailed test conditions. 2,5 1,9 2,5 1,9 standard version 1,9 130 205 350 2,5 mA mA mA mA IDD6 Self-Refresh Current: CKE <= 0.2V; external clock on; tCK = tCK MIN low power version 0,9 measured 1. IDD specifications are tested after the device is properly initialized and at 100 MHz for DDR200, 133 MHz for DDR266 and 166 MHz for DDR333 Operating Current: four bank; four bank interleaving with BL=4; 2. Input slew rate = 1V/ns. 164 IDD7 Refer to the following page for detailed test conditions. 3. Enables on-chip refresh and address counters 1, 2, 3 1,0 0,9 1,0 0,9 1,0 270 221 280 235 350 mA mA o 1. IDD the device properly andcondition measured 4. specifications Test conditionare fortested typicalafter values : VDD =is2.5V ,Ta =initialized 25 C, test for maximum values: test limit at VDD = 2.7V , at 100 MHz for Ta = 10oCDDR200, 133 MHz for DDR266 and 166 MHz for DDR333 2. Input slew rate = 1V/ns. 3. Enables on-chip refresh and address counters 4. Test condition for typical values : VDD = 2.5V ,Ta = 25°C, test condition for maximum values: test limit at VDD = 2.7V ,Ta = 10°C Page 56 of 76 1, 2 1, 2 2002-05-06 1, 2 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM IDD Current Measurement Conditions IDD1 : Operating current : One bank operation 1. Only one bank is accessed with tRC(min) , Burst Mode, Address and Control inputs on NOP edge are changing once per clock cycle. lout = 0 mA 2. Timing patterns - DDR200 (100Mhz, CL=2) : tCK = 10 ns, CL=2, BL=4, tRCD = 2 * tCK, tRAS = 5 * tCK Setup: A0 N R0 N N P0 N Read : A0 N R0 N N P0 N - repeat the same timing with random address changing 50% of data changing at every burst - DDR266A (133Mhz, CL=2) : tCK = 7.5 ns, CL=2, BL=4, tRCD = 3 * tCK, tRC = 9 * tCK, tRAS = 5 * tCK Setup: A0 N N R0 N P0 N N N Read : A0 N N R0 N P0 N NN - repeat the same timing with random address changing 50% of data changing at every burst - DDR333 (166Mhz, CL=2.5) : tCK = 6 ns, CL=2.5, BL=4, tRCD = 3 * tCK, tRC = 9 * tCK, tRAS = 5 * tCK Setup: A0 N N R0 N P0 N N N Read : A0 N N R0 N P0 N N N - repeat the same timing with random address changing 50% of data changing at every burst 3.Legend : A=Activate, R=Read, W=Write, P=Precharge, N=NOP IDD7 : Operating current: Four bank operation 1. Four banks are being interleaved with tRC(min) , Burst Mode, Address and Control inputs on NOP edge are not changing. lout = 0 mA 2. Timing patterns - DDR200 (100Mhz, CL=2) : tCK = 10 ns, CL=2, BL=4, tRRD = 2 * tCK, tRCD= 3 * tCK, Read with autoprecharge Setup: A0 N A1 R0 A2 R1 A3 R2 Read : A0 R3 A1 R0 A2 R1 A3 R2- repeat the same timing with random address changing 50% of data changing at every burst - DDR266A (133Mhz, CL=2) : tCK = 7.5 ns, CL=2, BL=4, tRRD = 2 * tCK, tRCD = 3 * tCK Setup: A0 N A1 R0 A2 R1 A3 R2 N R3 Read : A0 N A1 R0 A2 R1 A3 R2 N R3 - repeat the same timing with random address changing 50% of data changing at every burst - DDR333 (166Mhz, CL=2.5) : tCK = 6 ns, CL=2.5, BL=4, tRRD = 2 * tCK, tRCD = 3 * tCK Setup: A0 N A1 R0 A2 R1 A3 R2 N R3 Read : A0 N A1 R0 A2 R1 A3 R2 N R3 - repeat the same timing with random address changing 50% of data changing at every burst 3.Legend : A=Activate, R=Read, W=Write, P=Precharge, N=NOP 2002-05-06 Page 57 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM AC Characteristics (Notes 1-5 apply to the following Tables; Electrical Characteristics and DC Operating Conditions, AC Operating Conditions, I DD Specifications and Conditions, and Electrical Characteristics and AC Timing.) 1. All voltages referenced to VSS. 2. Tests for AC timing, IDD, and electrical, AC and DC characteristics, may be conducted at nominal reference/supply voltage levels, but the related specifications and device operation are guaranteed for the full voltage range specified. 3. The figure below represents the timing reference load used in defining the relevant timing parameters of the part. It is not intended to be either a precise representation of the typical system environment nor a depiction of the actual load presented by a production tester. System designers will use IBIS or other simulation tools to correlate the timing reference load to a system environment. Manufacturers will correlate to their production test conditions (generally a coaxial transmission line terminated at the tester electronics). 4. AC timing and IDD tests may use a VIL to VIH swing of up to 1.5V in the test environment, but input timing is still referenced to V REF (or to the crossing point for CK, CK), and parameter specifications are guaranteed for the specified AC input levels under normal use conditions. The minimum slew rate for the input signals is 1V/ns in the range between VIL(AC) and VIH(AC). 5. The AC and DC input level specifications are as defined in the SSTL_2 Standard (i.e. the receiver effectively switches as a result of the signal crossing the AC input level, and remains in that state as long as the signal does not ring back above (below) the DC input LOW (HIGH) level) 6. For System Characteristics like Setup & Holdtime Derating for Slew Rate, I/O Delta Rise/Fall Derating,DDR SDRAM Slew Rate Standards, Overshoot & Undershoot specification and Clamp V-I characteristics see the latest JEDEC specification for DDR components AC Output Load Circuit Diagram / Timing Reference Load VTT 50Ω Output Timing Reference Point (VOUT) 30pF AC Operating Conditions (0 °C ≤ TA ≤ 70 °C; VDDQ = 2.5V ± 0.2V; VDD = 2.5V ± 0.2V) Symbol Parameter/Condition VIH(AC) Input High (Logic 1) Voltage, DQ, DQS, and DM Signals VIL(AC) Input Low (Logic 0) Voltage, DQ, DQS, and DM Signals VID(AC) Input Differential Voltage, CK and CK Inputs VIX(AC) Input Closing Point Voltage, CK and CK Inputs 1. 2. 3. 4. Min Max Unit Notes V 1, 2 VREF − 0.31 V 1, 2 V DDQ + 0.6 V 1, 2, 3 V 1, 2, 4 V REF + 0.31 0.7 0.5*VDDQ − 0.2 0.5*V DDQ + 0.2 Input slew rate = 1V/ns. Inputs are not recognized as valid until VREF stabilizes. VID is the magnitude of the difference between the input level on CK and the input level on CK. The value of VIX is expected to equal 0.5*VDDQ of the transmitting device and must track variations in the DC level of the same. Page 58 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Electrical Characteristics & AC Timing - Absolute Specifications (0 °C ≤ TA ≤ 70 °C; VDDQ = 2.5V ± 0.2V; VDD = 2.5V ± 0.2V, See AC Characteristics) (Part 1 of 2) Symbol tAC DDR200 -8 Parameter DQ output access time from CK/CK tDQSCK DQS output access time from CK/CK DDR266A -7 DDR333 -6 Unit Notes + 0.7 ns 1-4 − 0.6 + 0.6 ns 1-4 Min Max Min Max Min Max − 0.8 + 0.8 − 0.75 + 0.75 − 0.7 − 0.8 + 0.8 − 0.75 + 0.75 tCH CK high-level width 0.45 0.55 0.45 0.55 0.45 0.55 tCK 1-4 tCL CK low-level width 0.45 0.55 0.45 0.55 0.45 0.55 tCK 1-4 tHP Clock Half Period ns 1-4 tCK tCK Clock cycle time tCK min (tCL , tCH ) min (tCL , tCH ) min (tCL, tCH ) CL = 3.0 8 12 7 12 6 12 ns 1-4 CL = 2.5 8 12 7 12 6 12 ns 1-4 CL = 2.0 10 12 7.5 12 7.5 12 ns 1-4 tDH DQ and DM input hold time 0.5 0.5 0.45 ns 1-4 tDS DQ and DM input setup time 0.5 0.5 0.45 ns 1-4 tIPW Control and Addr. input pulse width (each input) 2.5 2.2 2.2 ns 1-4,10 tDIPW DQ and DM input pulse width (each input) 2.0 1.75 1.75 ns 1-4,10 tHZ Data-out high-impedence time from CK/CK − 0.8 + 0.8 − 0.75 + 0.75 − 0.7 + 0.7 ns 1-4, 5 tLZ Data-out low-impedence time from CK/CK − 0.8 + 0.8 − 0.75 + 0.75 − 0.7 + 0.7 ns 1-4, 5 tDQSS Write command to 1st DQS latching transition 0.75 1.25 0.75 1.25 0.75 1.25 tCK 1-4 tDQSQ DQS-DQ skew (DQS & associated DQ signals) tQHS Data hold skew factor tQH DQ output hold time from DQS tDQSL,H DQS input low (high) pulse width (write cycle) + 0.6 + 0.5 + 0.45 ns 1-4 1.0 0.75 0.55 ns 1-4 tHP-tQHS tHP-tQHS tHP-tQHS ns 1-4 0.35 0.35 0.35 tCK 1-4 tDSS DQS falling edge to CK setup time (write cycle) 0.2 0.2 0.2 tCK 1-4 tDSH DQS falling edge hold time from CK (write cycle) 0.2 0.2 0.2 tCK 1-4 tMRD Mode register set command cycle time 2 2 2 tCK 1-4 0 0 0 ns 1-4, 7 tCK 1-4, 6 1-4 tWPRES Write preamble setup time tWPST Write postamble 0.40 tWPRE Write preamble 0.25 0.25 0.25 tCK fast slew rate 1.1 0.9 0.75 ns slow slew rate 1.1 1.0 0.8 ns fast slew rate 1.1 0.9 0.75 ns slow slew rate 1.1 1.0 0.8 ns tIS tIH Address and control input setup time Address and control input hold time 0.60 0.40 0.60 0.40 0.60 2-4, 10,11 tRPRE Read preamble 0.9 1.1 0.9 1.1 0.9 1.1 tCK 1-4 tRPST Read postamble 0.40 0.60 0.40 0.60 0.40 0.60 tCK 1-4 tRAS Active to Precharge command 50 120,000 45 120,000 42 70,000 ns 1-4 tRC Active to Active/Auto-refresh command period 70 ns 1-4 2002-05-06 65 60 Page 59 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Electrical Characteristics & AC Timing - Absolute Specifications (0 °C ≤ TA ≤ 70 °C; VDDQ = 2.5V ± 0.2V; VDD = 2.5V ± 0.2V, See AC Characteristics) (Part 2 of 2) Symbol DDR200 -8 Parameter Min Max DDR266A -7 Min Max DDR333 -6 Min Unit Notes Max tRFC Auto-refresh to Active/Auto-refresh command period 80 75 72 ns 1-4 tRCD Active to Read or Write delay 20 20 18 ns 1-4 tRP Precharge command period 20 20 18 ns 1-4 tRAP Active to Autoprecharge delay 20 20 18 ns 1-4 tRRD Active bank A to Active bank B command 15 15 12 ns 1-4 tWR Write recovery time 15 15 15 ns 1-4 tDAL Auto precharge write recovery + precharge time tCK 1-4,9 tWTR Internal write to read command delay 1 1 1 tCK 1-4 tXSNR Exit self-refresh to non-read command 80 75 75 ns 1-4 tXSRD Exit self-refresh to read command 200 200 200 tCK 1-4 tREFI Average Periodic Refresh Interval (4096 refresh commands per 64ms refresh period) µs 1-4, 8 (twr/tck) + (trp/tck) 15.6 15.6 15.6 1. Input slew rate >= 1V/ns for DDR266 & DDR333 and = 1V/ns for DDR200. 2. The CK/CK input reference level (for timing reference to CK/CK) is the point at which CK and CK cross: the input reference level for signals other than CK/CK, is VREF. CK/CK slew rate are >= 1.0 V/ns 3. Inputs are not recognized as valid until VREF stabilizes. 4. The Output timing reference level, as measured at the timing reference point indicated in AC Characteristics (Note 3) is VTT. 5. tHZ and tLZ transitions occur in the same access time windows as valid data transitions. These parameters are not referred to a specific voltage level, but specify when the device is no longer driving (HZ), or begins driving (LZ). 6. The maximum limit for this parameter is not a device limit. The device operates with a greater value for this parameter, but system performance (bus turnaround) degrades accordingly. 7. The specific requirement is that DQS be valid (HIGH, LOW, or some point on a valid transition) on or before this CK edge. A valid transition is defined as monotonic and meeting the input slew rate specifications of the device. When no writes were previously in progress on the bus, DQS will be transitioning from Hi-Z to logic LOW. If a previous write was in progress, DQS could be HIGH, LOW, or transitioning from HIGH to LOW at this time, depending on tDQSS. 8. A maximum of eight Autorefresh commands can be posted to any given DDR SDRAM device. 9. For each of the terms, if not already an integer, round to the next highest integer. tCK is equal to the actual system clock cycle time. 10. These parameters guarantee device timing, but they are not necessarily tested on each device 11. Fast slew rate >= 1.0 V/ns , slow slew rate >= 0.5 V/ns and < 1V/ns for command/address and CK & CK slew rate >1.0 V/ns, measured between VOH(ac) and VOL(ac) Page 60 of 76 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Electrical Characteristics & AC Timing for DDR266 - Applicable Specifications Expressed in Clock Cycles (0 °C ≤ TA ≤ 70 °C; VDDQ = 2.5V ± 0.2V; VDD = 2.5V ± 0.2V, See AC Characteristics) DD266A @ CL=2 Symbol Parameter Units Notes 2 tCK 1-5 0.25 tCK 1-5 tCK 1-5 Min tMRD tWPRE Mode register set command cycle time Write preamble Max tRAS Active to Precharge command 6 tRC Active to Active/Auto-refresh command period 9 tCK 1-5 tRFC Auto-refresh to Active/Auto-refresh command period 10 tCK 1-5 tRCD Active to Read or Write delay 3 tCK 1-5 Precharge command period 3 tCK 1-5 tRRD Active bank A to Active bank B command 2 tCK 1-5 tWR Write recovery time 2 tCK 1-5 tDAL Auto precharge write recovery + precharge time 5 tCK 1-5 tWTR Internal write to read command delay 1 tCK 1-5 tXSNR Exit self-refresh to non-read command 10 tCK 1-5 tXSRD Exit self-refresh to read command 200 tCK 1-5 tRP 16000 1. Input slew rate = 1V/ns 2. The CK/CK input reference level (for timing reference to CK/CK) is the point at which CK and CK cross: the input reference level for signals other than CK/CK, is VREF. 3. Inputs are not recognized as valid until VREF stabilizes. 4. The Output timing reference level, as measured at the timing reference point indicated in AC Characteristics (Note 3) is VTT. 5. tHZ and tLZ transitions occur in the same access time windows as valid data transitions. These parameters are not referred to a specific voltage level, but specify when the device is no longer driving (HZ), or begins driving (LZ). 2002-05-06 Page 61 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Timing Diagrams Data Input (Write) (Timing Burst Length = 4) tDQSL tDQSH DQS tDH tDS DI n DQ tDH tDS DM DI n = Data In for column n. 3 subsequent elements of data in are applied in programmed order following DI n. Data Output (Read) Don’t Care (Timing Burst Length = 4) DQS tDQSQ max tQH DQ tQH (Data output hold time from DQS) tDQSQ and tQH are only shown once and are shown referenced to different edges of DQS, only for clarify of illustration. t.DQSQ and tQH both apply to each of the four relevant edges of DQS. tDQSQ max. is used to determine the worst case setup time for controller data capture. tQH is used to determine the worst case hold time for controller data capture. Page 62 of 76 2002-05-06 2002-05-06 tVTD High-Z High-Z 200µs Power-up: VDD and CK stable LVCMOS LOW LEVEL Don’t Care DQ DQS BA0, BA1 A10 A0-A9, A11 DM Command CKE CK CK VREF VTT (System*) VDDQ VDD tIH tIH NOP tIS tIS tCH tIS tIH PRE tCL tIH tIH tIH BA1=L BA0=H tIS CODE tIS CODE tIS EMRS tIH CODE CODE MRS tMRD Load Mode Register (with A8 = L) BA0=L AR tRFC BA1=L AR tRFC 200 cycles of CK** BA0=L ALL BANKS tIS PRE tRP BA1=L CODE CODE MRS tMRD Load Mode Register, Reset DLL tMRD Extended Mode Register Set ALL BANKS tCK The two Autorefresh commands may be moved to follow the first MRS, but precede the second Precharge All command. ** t MRD is required before any command can be applied and 200 cycles of CK are required before a Read command can be applied. * VTT is not applied directly to the device, however tVTD must be greater than or equal to zero to avoid device latchup. BA RA RA ACT HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Initialize and Mode Register Sets Page 63 of 76 Page 64 of 76 tIH tIH tIH VALID tIS VALID* tIS tIS tCK Enter Power Down Mode NOP tIS tCH tCL No column accesses are allowed to be in progress at the time power down is entered. * = If this command is a Precharge (or if the device is already in the idle state) then the power down mode shown is Precharge power down. If this command is an Active (or if at least one row is already active), then the power down mode shown is Active power down. DM DQ DQS ADDR Command CKE CK CK Exit Power Down Mode NOP tIS Don’t Care VALID VALID HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Power Down Mode 2002-05-06 2002-05-06 tIH tIH NOP AR NOP AR NOP VALID tRFC NOP ACT tIH BANK(S) tIS ONE BANK PRE = Precharge; ACT = Active; RA = Row address; BA = Bank address; AR = Autorefresh. NOP commands are shown for ease of illustration; other valid commands may be possible at these times. DM, DQ, and DQS signals are all don't care/high-Z for operations shown. DM DQ DQS BA0, BA1 A10 Don’t Care BA RA RA ALL BANKS NOP tRFC A9, A11,A11 PRE VALID tCL RA NOP tIS tIS tCK tRP A0-A8 Command CKE CK CK tCH HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Auto Refresh Mode Page 65 of 76 Page 66 of 76 DM DQ DQS ADDR Command CKE CK CK NOP tIH tIH tCH tCK tIS AR Enter Self Refresh Mode tCL * = Device must be in the all banks idle state before entering Self Refresh Mode. ** = tXSNR is required before any non-read command can be applied, and tXSRD (200 cycles of CK). are required before a Read command can be applied. tIS tIS tRP* Exit Self Refresh Mode NOP tXSRD, tXSRN tIS 200 cycles tIH Don’t Care VALID tIS VALID Clock must be stable before exiting Self Refresh Mode HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Self Refresh Mode 2002-05-06 2002-05-06 Case 2: tAC/tDQSCK = max Case 1: t AC/tDQSCK = min tIH tIH NOP tIS tIS tIH tLZ (max) tLZ (max) tRPRE DO n tAC (max) DO n tAC (min) NOP NOP tDQSCK (max) NOP commands are shown for ease of illustration; other commands may be valid at these times. DIS AP = Disable Auto Precharge. * = Don't care if A10 is High at this point. PRE = Precharge; ACT = Active; RA = Row address; BA = Bank address. BA x RA RA ACT tHZ (max) tRPST tHZ (min) tIH tDQSCK (min) tRPST tRP 3 subsequent elements of data out are provided in the programmed order following DO n. CL=2 tLZ (min) tRPRE BA x* ALL BANKS PRE tCL BA x NOP tCH ONE BANK tIH tCK DIS AP tIH tIS tIS COL n tIS Read DO n = data out from column n. DQ DQS DQ DQS DM BA0, BA1 A10 A0-A9, A11, A11 Command CKE CK CK NOP VALID NOP VALID Don’t Care NOP VALID HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Read without Auto Precharge (Burst Length = 4) Page 67 of 76 Page 68 of 76 Case 2: tAC/tDQSCK = max Case 1: tAC/tDQSCK = min DQ DQS DQ DQS DM BA0, BA1 A10 A0-A9, A11, A11 Command CKE CK CK tIH tIH tIH tIH tIH BA x tIS EN AP tIS COL n tIS Read tLZ (max) tRPRE tLZ (max) CL=2 tHZ (min) NOP DO n tAC (max) DO n tAC (min) NOP tCL tLZ (min) tRPRE NOP tCH tHZ (min) BA x RA RA ACT tDQSCK (max) tHZ (max) tRPST NOP tIH tDQSCK (min) tRPST tRP NOP VALID DO n = data out from column n. 3 subsequent elements of data out are provided in the programmed order following DO n. EN AP = enable Auto Precharge. ACT = active; RA = row address. NOP commands are shown for ease of illustration; other commands may be valid at these times. NOP tIS tIS tCK NOP VALID Don’t Care NOP VALID HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Read with Auto Precharge (Burst Length = 4) 2002-05-06 2002-05-06 tIH tIH DQ DQS DQ BA x tIH tRCD NOP tCH tIH tRAS BA x DIS AP tIS COL n Read tCL tLZ (max) NOP DO n tAC (max) DO n tAC (min) BA x* ONE BANK tLZ (max) tRPRE tLZ (min) CL=2 PRE ALL BANKS tRC tLZ (min) tRPRE NOP DO n = data out from column n. 3 subsequent elements of data out are provided in the programmed order following DO n. DIS AP = disable Auto Precharge. * = Don't care if A10 is High at this point. PRE = Precharge; ACT = Active; RA = Row address; BA = Bank address. NOP commands are shown for ease of illustration; other commands may be valid at these times. Case 2: tAC/tDQSCK = max Case 1: t AC/tDQSCK = min DQS DM BA0, BA1 tIS RA tIH A10 tIS ACT RA NOP tIS tIS A0-A9, A11, A11 Command CKE CK CK tCK tDQSCK BA x RA RA ACT tHZ (max) tHZ (min) tRPST (max) tDQSCK (min) tRPST tRP NOP Don’t Care NOP VALID HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Bank Read Access (Burst Length = 4) Page 69 of 76 Page 70 of 76 DM DQ DQS BA0, BA1 A10 A0-A9, A11 Command CKE CK CK tIH tIH tIH tIH tWPRES tDQSS tIH BA x tIS DIS AP tIS COL n tIS Write DIn tDQSH tWPRE NOP tDQSL tCH tCL NOP tWPST tDSH NOP tIH NOP tWR PRE BA x* ONE BANK ALL BANKS tDQSS = min. DIn = Data in for column n. 3 subsequent elements of data in are applied in the programmed order following DIn. DIS AP = Disable Auto Precharge. * = Don't care if A10 is High at this point. PRE = Precharge; ACT = Active; RA = Row address; BA = Bank address. NOP commands are shown for ease of illustration; other valid commands may be possible at these times. NOP tIS tIS tCK NOP VALID tRP NOP Don’t Care BA RA RA ACT HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Write without Auto Precharge (Burst Length = 4) 2002-05-06 2002-05-06 DM DQ DQS BA0, BA1 A10 A0-A9, A11, A12 Command CKE CK CK tIH tIH tWPRE tWPRES tDQSS tIH BA x tIS EN AP tIS COL n tIS Write DIn tDQSH NOP tCH tDQSL NOP tCL tWPST tDSH NOP NOP VALID tWR DIn = Data in for column n. 3 subsequent elements of data in are applied in the programmed order following DIn. EN AP = Enable Auto Precharge. ACT = Active; RA = Row address; BA = Bank address. NOP commands are shown for ease of illustration; other valid commands may be possible at these times. tDQSS = min. tIH tIH NOP tIS tIS tCK NOP VALID tDAL NOP VALID tRP NOP Don’t Care BA RA RA ACT HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Write with Auto Precharge (Burst Length = 4) Page 71 of 76 Page 72 of 76 tIH tIH DM DQ DQS BA0, BA1 tIH tIH tRCD NOP tCH tIH tWPRES BA x tDQSS DIS AP tIS Col n Write tCL DIn tDSH tDQSL tWPRE tDQSH NOP tRAS NOP tWPST NOP tDQSS = min. DI n = data in for column n. 3 subsequent elements of data in are applied in the programmed order following DI n. DIS AP = Disable Auto Precharge. * = don't care if A10 is High at this point. PRE = Precharge; ACT = Active; RA = Row address. NOP commands are shown for ease of illustration; other valid commands may be possible at these times. BA x tIS RA A10 tIS ACT RA NOP tIS tIS A0-A9, A11 Command CKE CK CK tCK tWR NOP BA x ONE BANK ALL BANKS PRE Don’t Care NOP VALID HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Bank Write Access (Burst Length = 4) 2002-05-06 2002-05-06 DM DQ DQS BA0, BA1 A10 A0-A9, A11 Command CKE CK CK tIH tIH tIH tIH tIH tWPRES BA x tIS tDQSS DIS AP tIS COL n tIS Write DIn tDQSH NOP tCH tDQSL tCL NOP tWPST tDSH NOP tWR NOP BA x* ONE BANK ALL BANKS PRE NOP VALID DI n = data in for column n. 3 subsequent elements of data in are applied in the programmed order following DI n (the second element of the 4 is masked). DIS AP = Disable Auto Precharge. * = Don't care if A10 is High at this point. PRE = Precharge; ACT = Active; RA = Row address; BA = Bank address. NOP commands are shown for ease of illustration; other valid commands may be possible at these times. tDQSS = min. NOP tIS tIS tCK tRP NOP Don’t Care BA RA RA ACT HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Write DM Operation (Burst Length = 4) Page 73 of 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Package Dimensions 0 ,3 Le a d # 1 Page 74 of 76 ±0 ,08 0 ,80 5 R E F 22 ,22 ±0,1 3 G a ug e P la ne 1 0,1 6±0 ,13 0,25 Basic 0 ,65 B a sic 1,20 max 0,05 min Plastic Package, P-TSOPII-66 (400mil; 66 lead) Thin Small Outline Package 0 .1 S e a ting P lan e 0 ,5 ±0 ,1 1 1 ,7 6 ±0 ,2 T S O P 66 2002-05-06 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM TABLE OF CONTENT Features 1 Description Pin Configuration Input/Output Functional Description Block Diagram (32Mb x 4) Block Diagram (16Mb x 8) Block Diagram (8Mb x 16) 1 2 3 5 6 7 Functional Description Initialization Register Definition Mode Register Operation Burst Definition Required CAS Latencies Extended Mode Register Extended Mode Register Definition 8 8 9 10 11 12 13 14 Commands Delesect, No Operation Mode Register Set Active Read Write Precharge Auto Precharge Burst Terminate Auto Refresh Self Refresh 15 15 15 15 15 15 15 16 16 16 16 Truth Table 1a: Commands Truth Table 1b: DM Operation 17 17 Operations Activating a Specific Row in a Specific Bank tRCD and tRRD Definition Read Command Read Burst Consecutive Read Bursts Non-Consecutive Read Bursts Random Read Accesses Terminating a Read Burst Read to Write Read to Precharge Write Command Write Burst (Burst Length = 4) Write to Write (Burst Length = 4) Write to Write Random Write Cycles 18 18 19 20 21 22 23 24 26 27 28 30 31 32 33 34 2002-05-06 Page 75 of 76 Write to Read Write to Read Interrupting Write to Read: Minimum DQSS Write to Read: Nominal DQSS Write to Precharge Non-Interrupting Write to Precharge Interrupting Write to Precharge Minimum DQSS Write to Precharge: Nominal DQSS Precharge Power-Down Truth Table 2: Clock Enable (CKE) Truth Table 3: Current State, SameBank Truth Table 4: Current State,Different Bank Truth Table 5: Concurrent Auto Precharge Simplified State Diagram 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 Operating Conditions Absolute Maximum Ratings Input and Output Capacitances DC Electrical Operating Conditions Normal Mode Pulldown Characteristics Normal ModePullup Characteristics Normal ModePulldown and Pullup Currents Weak Mode Pulldown Characteristics Weak ModePullup Characteristics Weak ModePulldown and Pullup Currents IDD Specifications and Conditions AC Characteristics AC Output Load Circuit Diagram AC Operating Conditions 50 50 50 51 52 52 53 54 55 56 56 58 58 60 Electrical Characteristics & AC Timing 61 Timing Diagrams Data Input (Write) Data Output (Read) Initialize and Mode Register Sets Power Down Mode Auto Refresh Mode Self Refresh Mode Read without Auto Precharge Read with Auto Precharge Bank Read Access Write without Auto Precharge. Write with Auto Precharge Bank Write Access Write DM Operation 62 62 62 63 64 65 66 67 68 69 70 71 72 73 Package Dimensions Table of Content Security Information 74 75 76 HYB25D128400/800/160AT(L) 128-Mbit Double Data Rate SDRAM Attention please ! As far as patents or other rights of third parties are concerned, liability is only assumed for components, not for applications, processes and circuits implemented within components or assemblies. This information describes the type of components and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. For questions on technology, delivery and prices please contact INFINEON Technologies Offices in Munich or the INFINEON Technologies Sales Offices and Representatives worldwide. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact your nearest INFINEON Technologies office or representative. Packing Please use the recycling operators known to you. We can help you - get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components1 of INFINEON Technologies, may only be used in lifesupport devices or systems2 with the express written approval of INFINEON Technologies. 1. A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that lifesupport device or system, or to affect the safety or effectiveness of that device or system. 2. Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered. 2002-05-06 Page 76 of 76