ETC 48D5.1700NT

20 Watt NT Dual Series DC/DC Converters
Features
!
Fully Self Contained, No External Parts
Required for Operation
!
Low and Specified Input/Output Capacitance
!
Efficiencies to 85%
!
Overcurrent Protected and Thermal Shutdown
Circuitry for Long, Reliable Operation
!
Five Sided Shielded Low Thermal Gradient
Copper Case
!
Five Year Warranty
!
Water Washable Case Design
Description
Selection Chart
Designed to save valuable PC board space, the 20 Watt NT
Dual series is ideal for use in battery operated industrial,
medical control and remote data collection systems. Each unit
is completely filtered to reduce noise, has an exceptionally
low input/output capacitance and provides efficiencies to
85%.
Model
Complete overload protection with independent pulse-bypulse current limiting and an overtemperature shutdown
circuit ensure zero-failure rate operation. Their copper cases
are five-sided, shielded and water washable.
Input Range
VDC
Output
VDC
Output
mA
1700
Min
Max
12D5.1700NT
9
18
±5
12D12.850NT
9
18
±12
850
12D15.700NT
9
18
±15
700
1700
24D5.1700NT
18
36
±5
24D12.850NT
18
36
±12
850
24D15.700NT
18
36
±15
700
1700
48D5.1700NT
36
72 *
±5
48D12.850NT
36
72 *
±12
850
48D15.700NT
36
72 *
±15
700
* UL Recognition only applies up to 60 VDC
20 Watt NT Dual Series Block Diagram
A
2401 Stanwell Drive • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: [email protected]
1
eco: 010403-2
20 Watt NT Dual Series DC/DC Converters
Input Parameters*
Model
12D5.1700NT
Reflected Ripple (1)
MIN
MAX
TYP
12D12.850NT
9.0
18.0
350
Input Current No Load
Full Load
Efficiency
TYP
TYP
TYP
TYP
100
40
2170
78
Voltage Range
Switching Frequency
Maximum Input
Overvoltage,
100 ms maximum
Turn-on Time,
1% Output Error
Recommended Fuse
40
1750
81
12D15.700NT
24D5.1700NT
40
2210
79
TYP
40
875
81
VDC
mA P-P
40
40
1010
84
mA RMS
40
1030
85
45
TYP
mA
%
VDC
6
ms
(2)
AMPS
Reflected Ripple (1)
MIN
MAX
TYP
48D12.850NT
36.0
72.0 *
90
Input Current No Load
Full Load
Efficiency
TYP
TYP
TYP
TYP
25
40
505
84
40
440
81
Units
kHz
24
48D5.1700NT
Switching Frequency
Maximum Input
Overvoltage,
100 ms maximum
Turn-on Time,
1% Output Error
Recommended Fuse
24D15.700NT
220
MAX
Model
Voltage Range
24D12.850NT
18.0
36.0
140
48D15.700NT
Units
VDC
mA P-P
mA RMS
40
520
84
mA
%
TYP
220
kHz
MAX
85
VDC
TYP
6
ms
(2)
AMPS
* UL Recognition only applies up to 60 VDC
Output Parameters*
Model
Output Voltage
Cross Regulation (13)
Line Regulation
Vin = Min-Max VDC
Short Term Stability (5)
MIN
TYP
MAX
TYP
MAX
MIN
MAX
TYP
MAX
TYP
TYP
MAX
TYP
Long Term Stability
Transient Response (6)
Dynamic Response (7)
Input Ripple Rejection (8)
TYP
TYP
TYP
TYP
Noise, 0-20MHz bw (1)
RMS Noise, 0.01-1 MHz bw
TYP
TYP
TYP
MAX
Output Voltage Accuracy
Output Balance
Plus to Minus Output, Full Load
Rated Load Range
Load Regulation (12)
Temperature Coefficient
Short Circuit Protection to
Common for all Outputs
12D5.1700NT
24D5.1700NT
48D5.1700NT
±5
4.95
5.00
5.05
12D12.850NT
24D12.850NT
48D12.850NT
±12
11.90
12.00
12.10
< 0.5
1.0
0.0
0.85
0.1
0.6
1.0
< 0.2
0.8
< 0.05
0.0
1.7
0.3
0.7
2.5
< 0.1
0.8
< 0.2
100
120
> 40
100
70
50
15
50
10
50
150
A
12D15.700NT
24D15.700NT
48D15.700NT
±15
14.90
15.00
15.10
Units
VDC
VDC
%
0.0
0.7
0.2
0.6
1.0
< 0.2
0.8
A
%
%
%
%/24Hrs
Output never exceeds 1%
100
%/kHrs
µs
mV peak
dB
50
10
mV P-P
mV RMS
ppm/°C
Continuous, Current Limit and Thermal Protection
2401 Stanwell Drive • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: [email protected]
2
eco: 010403-2
20 Watt NT Dual Series DC/DC Converters
General Specifications*
All Models
ON/OFF Function
ON Logic Level
or Leave Pin Open
OFF Logic Level
or Tie Pin to -Input
Open Circuit Voltage
Input Resistance
Converter Idle Current
ON/OFF Pin Low
12S Models
24S and 48S Models
Units
MIN
> 1.6
VDC
MAX
< 0.7
VDC
TYP
TYP
2.5
20
VDC
kohms
TYP
TYP
13
14
mA
mA
MIN
MIN
700
1544
VDC
TYP
500
pF
MIN
MIN
±5
60
%
kohms
MIN
MAX
MIN
Case Functional Range (10)
MAX
MIN
Storage Range
MAX
Thermal Shutdown
TYP
Case Temperature
Thermal Impedance (11)
TYP
-40
90
-50
100
-55
105
°C
105
°C
9.5
°C/Watt
Isolation (3)
Breakdown Voltage
Input to Output 12D, 24D
Input to Output 48D
10 µA Leakage
Input to Output
Capacitance
Output Trim Function
Trim Range
Input Resistance
BOTTOM VIEW
Mechanical tolerances unless otherwise noted:
X.XX dimensions: ±0.020 inches
Environmental
Case Operating Range
No Derating
X.XXX dimensions: ±0.005 inches
Pin
1
2
3
4
5
6
7
°C
°C
General
Unit Weight
Chassis Mounting Kit
Agency Approvals
SIDE VIEW
TYP
2.3
oz
(11)
MS8
(12)
UL1950, see note
Note: On nominal 48Vin models UL recognition only applies up to 60 VDC
(13)
NOTES
parameters measured at Tc=25°C, nominal input
* All
voltage and full rated load unless otherwise noted.
Refer to the CALEX Application Notes for the definition
of terms, measurement circuits and other information.
(1) Noise is measured per CALEX Application Notes. Measurement
bandwidth is 0-20 MHz for peak-peak measurements, 10 kHz
to 1 MHz for RMS measurements. Output noise is measured
with a 0.01µF ceramic in parallel with a 1µF tantalum located
1" away from the converter to simulate your boards standard
decoupling. Input reflected ripple is measured into a 1 µH
source impedance.
(2) To determine the correct fuse size, see CALEX Application
Notes.
(3) The Case is tied to the -Input pin.
(5) Short term stability is specified after a 30 minute warmup at full
load, constant line and recording the drift over a 24 hour period.
(6) The transient response is specified as the time required to settle
from a 50 to 75 % step load change on one output (rise time of
step = 2 µSec) to a 1% error band.
(7) Dynamic response is the peak overshoot during a transient as
defined in note 6 above.
(8) The input ripple rejection is specified for DC to 120 Hz ripple with
a modulation amplitude of 1% of Vin.
(10) The functional temperature range is intended to give an additional
data point for use in evaluating this power supply. At the
low functional temperature the power supply will function with no
(14)
Function
ON/OFF
-INPUT
+INPUT
+OUTPUT
CMN
-OUTPUT
TRIM
side effects, however sustained operation at the high
functional temperature will reduce expected operational life.
The data sheet specifications are not guaranteed over the
functional temperature range.
The case thermal impedance is specified as the case temperature
rise over ambient per package watt dissipated.
Load regulation is defined as the voltage change on either output
as the loads on both outputs are changed from 25% to 100% full
load at the same time.
Cross regulation is defined as the change in one output when the
other output is changed from 25% to 100% full load.
Specifications subject to change without notice.
A
Applications Information
The 20 Watt NT Dual series like all CALEX converters carries
the full 5 year CALEX no hassle warranty. We can offer a five
year warranty where others can’t because with CALEX it’s
rarely needed.
General Information
The 20 Watt NT Dual series is mindful of battery operation for
industrial, medical control and remote data collection
applications. The remote ON/OFF pin places the converter in
a very low power mode that draws typically less than 3 mA
from the input source.
Full overload protection is provided by independent pulseby-pulse current limiting and an over-temperature shutdown
circuit. These protection features assure you that our 20 Watt
Dual will provide you with zero failure rate operation.
A fully five sided shielding, sealed, water washable case is
standard along with specified operation over the full commercial
temperature range of -40 to +90°C.
2401 Stanwell Drive • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: [email protected]
3
eco: 010403-2
20 Watt NT Dual Series DC/DC Converters
General Operation
Applying The Input
Figure 1 shows the recommended connections for the 20
Watt NT Dual DC/DC converter. A fuse is recommended to
protect the input circuit and should not be omitted. The fuse
serves the purpose of preventing unlimited current from
flowing in the case of a catastrophic system failure.
Figure 2.
For very low noise applications the circuits shown above can be
used. The input current ripple will be reduced approximately 30 dB
of the original value while the output noise will be reduced to below
10 mV P-P.
*
*
D - Overvoltage clamp is optional, see text
* - No connection needed if not used.
Figure 1.
Standard connections for the 20 Watt NT Dual. The ON/OFF and
TRIM pins can be left floating if they are not used. The input fuse
should not be omitted. The overvoltage diodes may be added to the
circuit directly at the converter to provide transient protection to your
circuit.
Figure 3.
The output can be trimmed by either a trimpot or fixed resistors. If
fixed resistors are used their values may range from 0 to infinite
ohms. The trimpot should be 20 K ohms nominal.
The ON/OFF and TRIM pins may be left floating if they are
not used. No external capacitance on either the input or
outputs is required for normal operation, in fact it can degrade
the converters performance. See our application note
“Understanding DC/DC Converters Output Impedance” and
the low noise circuits later in this data sheet for more
information. The usual 1 µF to 10 µF tantalum and 0.1 to
0.001 µF ceramic bypasses may be used around your PCB
as required for local bypassing without harm.
Non Standard Output Voltages/Single
Ended Mode
The trim may be used to adjust a +5 output unit up to 5.2 volts
for ECL applications or to make up for line voltage drops. +5
output units will trim around a range of approximately +4.2 to
+5.3 volts.
+12 volt units will trim around a range of approximately
+7.4 to +12.9 volts and +15 volt units will trim around a range
of approximately +8.6 to +16 volts.
A
Extremely low ESR capacitors (< 0.5 ohms) should not be
used at the input as this will cause peaking of the input filters
transfer function and actually degrade the filters performance.
The dual outputs may also be used single-ended to get
10, 24 or 30 volts output at the full rated current of 1.7, 0.85
or 0.7 Amps (see figure 4). To use the single ended mode just
connect your load to the + and - output terminals and leave
the CMN output floating. Trimming of the output voltage may
also be done while using the outputs in the single ended
mode.
Applying The Output
The output is simply connected to your application circuit and
away you go. If extra low output noise is required in your
application the circuit shown in Figure 2 may be used to
reduce the output noise to below 10 mV peak-peak.
Maximum power from the module is limited to the specified
non-trimmed maximum (Typical Output Voltage x Maximum
Rated Load = Maximum Power). Trimming the output up
reduces the output current proportionally to keep the maximum
power constant. Output current is not increased over the
Rated Maximum when trimming the output voltage down.
The trim pin may be used to adjust the outputs by up to +5
% from the nominal factory setting to account for system
wiring voltage drops. Figure 3 shows the proper connections
to use the trim pin. If output trimming is not desired the trim pin
may be safely left floating.
See our application note on remote sense and trim
functions for more information.
2401 Stanwell Drive • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: [email protected]
4
eco: 010403-2
20 Watt NT Dual Series DC/DC Converters
Operation
The remote ON/OFF pin may be left floating if this function is
not used. The equivalent input circuit for the ON/OFF pin is
shown in figure 5. The best way to drive this pin is with an open
collector/drain or relay contact. See our application note titled
“Understanding the remote ON/OFF function” for more
information about using the remote ON/OFF pin.
Figure 4.
To get 10, 24 or 30 volt outputs use the NT dual in the “Single Ended”
mode. In this mode the load is taken across the + to - pins with the
CMN pin left floating. Output Current in this mode is the full rated 1.7,
0.85 or 0.7 Amps. Output trimming may optionally be used as shown
in figure 3.
Figure 5.
The simplified schematic of the NT Dual series ON/OFF pin. The
input impedance is approximately 20 kohms. The open circuit
voltage is approximately 2.5 volts. By leaving this pin floating the
converter will be in the ON state. When the pin is pulled below 0.7
volts the converter is placed in the power down or OFF state. See
our application note on the remote ON/OFF function for more
information.
Grounding
The input and output sections are fully floating from each
other. They may be operated fully floating or with a common
ground. If the input and output sections are connected either
directly at the converter or at some remote location from the
converter it is suggested that a 1 to 10µF, 0.5 to 5 ohm ESR
capacitor bypass be used directly at the converter output pins.
This capacitor prevents any common mode switching currents
from showing up at the converters output as normal mode
output noise. Do not use the lowest ESR, biggest value
capacitor that you can find! This can only lead to reduced
system performance or oscillation. See our application note
“Understanding Output Impedance For Optimum Decoupling”
for more information.
When the ON/OFF pin is pulled low with respect to the Input, the converter is placed in a low power drain state. When
the ON/OFF pin is released the converter fully powers up in
typically 10 milliseconds. The ON/OFF pin turns the converter
off while keeping the input bulk capacitor fully charged, this
prevents the large inrush current spike that occurs when the
+input pin is opened and closed.
Temperature Derating
Another useful “Trick” that can be used when operating
with a common ground is to use a 10 to 100 µH choke between
the grounds. This gives you a solid low frequency ground
connection, but looks like a high impedance to the switching
current effects and prevents them from flowing in the
connection. This will have the effect of preventing the common
mode currents from showing up as normal mode components
in your output or input circuits. Be sure that the “Q” of this
inductor is quite low and that the self resonant frequency is
above 220 kHz. If necessary to keep the inductor “Q” low,
parallel it with a 200 ohm to 1k ohm resistor.
The NT Dual series can operate up to 90°C case temperature
without derating. Case temperature may be roughly calculated
from ambient by knowing that the NT Duals case temperature
rise is approximately 9.5°C per package watt dissipated.
A
For example: If a 24 volt input converter was delivering 15
Watts, at 24 volts input at what ambient could it expect to run
with no moving air and no extra heatsinking?
Efficiency is approximately 82%, this leads to an input
power of about 18 Watts. The case temperature rise would be
3 Watts x 9.5 = 28.5°C. This number is subtracted from the
maximum case temperature of 90°C to get approximately:
62°C.
Case Grounding
This is a rough approximation to the maximum ambient
temperature. Because of the difficulty of defining ambient
temperature and the possibility that the loads dissipation may
actually increase the local ambient temperature significantly
or that convection cooling is suppressed by physical placement
of the module. These calculations should be verified by actual
measurement of operating temperature and your circuits
exact efficiency (efficiency depends on both line input and
load value) before committing to a production design.
The case serves not only as a heat sink but also as a EMI
shield. The 0.016 inch thick copper provides >25 dB of
absorption loss to both electromagnetic and electric fields at
220 kHz, while at the same time providing about 30% better
heat sinking than competitive 0.01 inch thick steel cases.
The case shield is tied to the -Input. This connection is
shown on the block diagram. The case is floating from the
output, coupled only by the 500 pF of isolation capacitance.
2401 Stanwell Drive • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: [email protected]
5
eco: 010403-2
20 Watt NT Dual Series DC/DC Converters
Typical Performance (Tc=25°C, Vin=Nom VDC, Rated Load).
12 VOLT EFFICIENCY Vs. LOAD
85
12 VOLT EFFICIENCY Vs. LINE INPUT VOLTAGE
12 VOLT INPUT CURRENT Vs. LINE INPUT VOLTAGE
3.5
85
LINE = 9VDC
LINE = 12VDC
LINE = 18VDC
75
INPUT CURRENT (AMPS)
80
EFFICIENCY(%)
EFFICIENCY (%)
50% FULL LOAD
80
100% FULL LOAD
75
3.0
2.5
100% LOAD
2.0
1.5
50% LOAD
1.0
0.5
70
70
0
10
20
30
40
50
60
70
80
90
100
0.0
9
10
11
LOAD (%)
13
14
15
16
17
18
0
24 VOLT EFFICIENCY Vs. LOAD
24 VOLT EFFICIENCY Vs. LINE INPUT VOLTAGE
80
LINE = 24VDC
LINE = 36VDC
10
20
30
100% FULL LOAD
85
50% FULL LOAD
80
75
40
50
60
70
80
90
100
20
22
LOAD (%)
48 VOLT EFFICIENCY Vs. LOAD
24
26
28
30
32
34
10
20
30
INPUT CURRENT (AMPS)
EFFICIENCY (%)
EFFICIENCY(%)
50
60
80
50% FULL LOAD
70
80
90
100
16
20
24
28
32
36
0.75
100% LOAD
0.50
50% LOAD
0.25
0.00
36
40
LOAD (%)
44
48
52
56
60
64
68
72
0
10
20
LINE INPUT(VOLTS)
30
40
50
60
70
80
LINE INPUT (VOLTS)
OUTPUT IMPEDANCE Vs. FREQUENCY
DERATING
120
10
A
INFINITE HEAT SINK
100
OUTPUT POWER (%)
OUTPUT IMPEDANCE (OHMS)
12
48 VOLT INPUT CURRENT Vs. LINE INPUT VOLTAGE
70
40
8
1.00
85
LINE = 72VDC
0
4
LINE INPUT (VOLTS)
75
60
18
50% LOAD
0.5
0
100% FULL LOAD
70
16
100% LOAD
48 VOLT EFFICIENCY Vs. LINE INPUT VOLTAGE
LINE = 48VDC
14
1.0
36
90
80
12
1.5
LINE INPUT(VOLTS)
LINE = 36VDC
10
0.0
18
90
8
24 VOLT INPUT CURRENT Vs. LINE INPUT VOLTAGE
75
0
6
2.0
INPUT CURRENT (AMPS)
EFFICIENCY(%)
LINE = 18VDC
70
4
LINE INPUT (VOLTS)
90
85
2
LINE INPUT(VOLTS)
90
EFFICIENCY (%)
12
1
80
NO HEAT SINK
↑
60
← SAFE OPERATING AREA →
40
↓
20
.1
0
10
100
1000
10000
100000
1000000
-40
FREQUENCY (Hz)
-20
0
20
40
60
80
100
AMBIENT TEMPERATURE (Deg C)
NOTES ON USING THE CURVES
1) The Input currents are for 20 Watts of output power. For ±5 Volt
output models the current is approximately 15% less.
2) The efficiency curves were generated for 12 Volt output models.
To use for other outputs adjust as follows:
±5 Volt outputs.......Subtract approximately 3%
±15 Volt outputs.....Add approximately 1%