ETC REF12D

THIS DOCUMENT IS FOR MAINTENANCE
PURPOSES ONLY AND IS NOT
RECOMMENDED FOR NEW DESIGNS
DS2475 - 2.1
REF12Z/REF12D
1.26V MICROPOWER PRECISION REFERENCE
The REF12Z and REF12D are integrated circuits using
the bandgap principle to provide a precise stable reference
voltage of 1.26V. There are two package options available:
REF12Z in a plastic 3-pin TO-92 and REF12D in a miniature
surface mount package (MP8).
These references feature a recommended operating current of 90µA to 2.5mA which make them ideal for all low power
and battery applications.
FEATURES
■
Low Knee Current - typically 80 microamps
■
Ideal for Battery Operation - 113 microwatts
■
REF12Z - 3 lead TO-92 Plastic Package
■
REF12D - Miniature Plastic Surface Mount Package
(MP8)
■
Tight Initial VREF Tolerance ±1%
■
Low Temperature Coefficient
■
Low Slope Resistance
■
Low Cost
■
Operation over Industrial Temperature Range
Fig.1 Pin connection
ORDERING INFORMATION
Device Type
Operating Temperature
Package
REF12Z
-40°C to +85°C
TO-92
REF12D
-40°C to +85°C
MP8
ABSOLUTE MAXIMUM RATINGS
Reference current
2.5mA
Operating temperature range:
REF12Z
-40 to +85°C
REF12D
-40 to +85°C
Storage temperature
-55 to +125°C
Storage temperature for a max. time of 10ns:
within 1.59mm of the seating plane
300°C
within 0.80mm of the seating plane
265°C
Fig.2 Internal connections
REF12Z/12D
ELECTRICAL CHARACTERISTICS
These characteristics are guaranteed over the following conditions (unless otherwise stated)
Tamb = 25°C, CS = 470nF (see Fig.3)
Value
Characteristic
VREF
Output voltage
Min.
Typ.
Max.
1.247
1.26
1.273
V
2.5
4.0
Ω
RREF
Slope resistance (Note 1)
Conditions
Units
Symbol
IREF = 150µA to 2.5mA
Note 1
Turn-on (knee) current
ION
Recommended operating
IREF
90
µA
2.5
mA
40
80
ppm/°C
REF12Z
30
80
ppm/°C
REF12D
0.1Hz to 25kHz
80
0.09
current range
Temperature coefficient
TC VREF
(Note 2)
RMS noise voltage
EN
1.0
µV/√Hz
Turn-on time
TON
0.4
ms
Turn-off time
TOFF
15
ms
Turn-on time
TON
5
ms
TOFF
110
ms
Turn-off time
Note 2
IREF = 1.5mA
IREF = 1.5mA
NOTES
1. Slope resistance (RREF)
Slope resistance is defined as
RREF = Change in VREF over a specified current range
The change in reference current
2. Reference voltage temperature coefficient (TC VREF)
This is the normalised reference voltage change over temperature, divided by the change in temperature.
It is expressed in ppm/°C
TC VREF =
∆VREF x 106
ppm/°C
VREF x ∆T
∆T = temperature change in °C
∆VREF = change in reference voltage over temperature change ∆T
2
REF12Z/12D
Fig.3 Connection diagram
3
REF12Z/12D
Fig.4 Typical reference characterics
Fig.5 Typical temperature characteristic
4
REF12Z/12D
Fig.6 Typical response time
5
REF12Z/12D
Fig.7 Typical derating curve
6
REF12Z/12D
7
REF12Z/12D
HEADQUARTERS OPERATIONS
GEC PLESSEY SEMICONDUCTORS
Cheney Manor, Swindon,
Wiltshire SN2 2QW, United Kingdom.
Tel: (0793) 518000
Fax: (0793) 518411
GEC PLESSEY SEMICONDUCTORS
Sequoia Research Park, 1500 Green Hills Road,
Scotts Valley, California 95066,
United States of America. Tel: (408) 438 2900
Fax: (408) 438 5576
CUSTOMER SERVICE CENTRES
• FRANCE & BENELUX Les Ulis Cedex Tel: (1) 64 46 23 45 Tx: 602858F
Fax : (1) 64 46 06 07
• GERMANY Munich Tel: (089) 3609 06-0 Tx: 523980 Fax : (089) 3609 06-55
• ITALY Milan Tel: (02) 66040867 Fax: (02) 66040993
• JAPAN Tokyo Tel: (03) 3296-0281 Fax: (03) 3296-0228
• NORTH AMERICA Integrated Circuits and Microwave Products Scotts Valley, USA
Tel (408) 438 2900 Fax: (408) 438 7023.
Hybrid Products, Farmingdale, USA Tel (516) 293 8686
Fax: (516) 293 0061.
• SOUTH EAST ASIA Singapore Tel: (65) 3827708 Fax: (65) 3828872
• SWEDEN Stockholm, Tel: 46 8 702 97 70 Fax: 46 8 640 47 36
• UNITED KINGDOM & SCANDINAVIA
Swindon Tel: (0793) 518510 Tx: 444410 Fax : (0793) 518582
These are supported by Agents and Distributors in major countries world-wide.
© GEC Plessey Semiconductors 1993 Publication No. DS2475 Issue No. 2.1 December 1993
This publication is issued to provide information only which (unless agreed by the Company in writing) may not be used, applied or reproduced for any purpose nor form part of any order or contract nor to be regarded
as a representation relating to the products or services concerned. No warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or service. The Company
reserves the right to alter without prior knowledge the specification, design or price of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute
any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user's responsibility to fully determine the performance and suitability of any equipment using such information
and to ensure that any publication or data used is up to date and has not been superseded. These products are not suitable for use in any medical products whose failure to perform may result in significant injury
or death to the user. All products and materials are sold and services provided subject to the Company's conditions of sale, which are available on request.
8