ETC LNG28URBA

Ultra Bright GaAIAs Lamps
Unit: mm
LN28RAL(US) ·········· LNG28URBA ··········· Red
2 Max. NOT SOLDERED
LN28RCAL(US) ······· LNG28ULBA ··········· Red
2 − 0.8 Max
1.0
4.5
6.5 ± 0.3
4.5 ± 0.2
Lighting Color
2.0
Global Prat No.
LN28WAL(US) ········· LNG28UWBA ·········· Red
LN28CAL(US) ·········· LNG28UCBA ··········· Red
2 − 0.5 ± 0.1
0.5 ± 0.1
■ Absolute Maximum Ratings (Ta = 25°C)
2.54
Lighting Color PD(mW) IF(mA) IFP(mA)∗ VR(V) Topr(°C) Tstg(°C)
Red
70
150
30
3
−25 ∼ +85 −30 ∼ +100
1
1.5
Conventional Part No.
φ 3.0 ± 0.2
15.5 ± 1.0
Round Type
φ 3.0 mm Series
2
1.7
Pulse width 1 msec. The condition of IFP is duty 10%, Pulse width 1 msec
1: Anode
2: Cathode
φ 3.8 ± 0.2
■ Electro−Optical Characteristics (Ta = 25°C)
Conventional
Part No.
LN28RAL(US)
LN28RCAL(US)
LN28WAL(US)
LN28CAL(US)
Unit
Lighting
Color
Red
Red
Red
Red
−
Typ
25
85
50
85
mcd
Red Diffused
Red Clear
White Diffused
Clear
−
Min
10
−
−
30
mcd
Typ
1.8
1.8
1.8
1.8
V
Max
2.6
2.6
2.6
2.6
V
50
30
Forward Current
5
10
5
3
3
1
1
3
5
10
30
50
1
100
1.6
1.8
Forward Current
2.0
2.2
100
50
30
0
20
40
60
80
100
Ambient Temperature
Forward Current
Relative Luminous Intensity
300
10
−20
2.4
Directive Characteristics
20° 10°
0°
30°
40°
60
10° 20°
30°
40°
80°
50°
50°
60°
60°
40
800
90°
100
80
60
40
LN28RAL(US)
LN28WAL(US)
LN28WAL(US)
20°
80°
20
0
20
40
60
Relative Luminous Intensity
80
40
30
20
60°
40°
70° LN28RCAL(US)
LN28CAL(US)
20
700
VR
3
3
3
3
V
50
80
Wavelength
Max
100
100
100
100
µA
IF  Ta
100
600
IR
IF
20
20
20
20
mA
500
Forward Voltage
Relative Luminous Intensity
Wavelength Characteristics
0
500
∆λ
Typ
20
20
20
20
nm
IO  Ta
Relative Luminous Intensity
50
10
IF
20
20
20
20
mA
IF  VF
100
L
LN N2
28 8RC
CA A
L( L(
LN
US US
) )
28
LN
W
28
RA AL
(U
L(
US S )
)
Luminous Intensity
IO  IF
100
30
λP
Typ
665
665
665
665
nm
VF
IO
Lens Color
70°
10
80°
90°
100
0
0
20
40
60
80
100
Ambient Temperature
241
Caution for Safety
Gallium arsenide material (GaAs) is used
in this product.
DANGER
Therefore, do not burn, destroy, cut, crush, or chemically decompose the product, since gallium arsenide
material in powder or vapor form is harmful to human
health.
Observe the relevant laws and regulations when disposing of the products. Do not mix them with ordinary industrial waste or household refuse when disposing of
GaAs-containing products.
Request for your special attention and precautions in using the technical information
and semiconductors described in this material
(1) An export permit needs to be obtained from the competent authorities of the Japanese Government if any of the
products or technologies described in this material and controlled under the "Foreign Exchange and Foreign
Trade Law" is to be exported or taken out of Japan.
(2) The technical information described in this material is limited to showing representative characteristics and
applied circuit examples of the products. It does not constitute the warranting of industrial property, the granting
of relative rights, or the granting of any license.
(3) The products described in this material are intended to be used for standard applications or general electronic
equipment (such as office equipment, communications equipment, measuring instruments and household appliances).
Consult our sales staff in advance for information on the following applications:
• Special applications (such as for airplanes, aerospace, automobiles, traffic control equipment, combustion
equipment, life support systems and safety devices) in which exceptional quality and reliability are required,
or if the failure or malfunction of the products may directly jeopardize life or harm the human body.
• Any applications other than the standard applications intended.
(4) The products and product specifications described in this material are subject to change without notice for
reasons of modification and/or improvement. At the final stage of your design, purchasing, or use of the products, therefore, ask for the most up-to-date Product Standards in advance to make sure that the latest specifications satisfy your requirements.
(5) When designing your equipment, comply with the guaranteed values, in particular those of maximum rating, the
range of operating power supply voltage and heat radiation characteristics. Otherwise, we will not be liable for
any defect which may arise later in your equipment.
Even when the products are used within the guaranteed values, redundant design is recommended, so that
such equipment may not violate relevant laws or regulations because of the function of our products.
(6) When using products for which dry packing is required, observe the conditions (including shelf life and afterunpacking standby time) agreed upon when specification sheets are individually exchanged.
(7) No part of this material may be reprinted or reproduced by any means without written permission from our
company.
Please read the following notes before using the datasheets
A. These materials are intended as a reference to assist customers with the selection of Panasonic semiconductor products best suited to their applications.
Due to modification or other reasons, any information contained in this material, such as available product
types, technical data, and so on, is subject to change without notice.
Customers are advised to contact our semiconductor sales office and obtain the latest information before
starting precise technical research and/or purchasing activities.
B. Panasonic is endeavoring to continually improve the quality and reliability of these materials but there is always
the possibility that further rectifications will be required in the future. Therefore, Panasonic will not assume any
liability for any damages arising from any errors etc. that may appear in this material.
C. These materials are solely intended for a customer's individual use.
Therefore, without the prior written approval of Panasonic, any other use such as reproducing, selling, or
distributing this material to a third party, via the Internet or in any other way, is prohibited.
2001 MAR