CYAN MAGENTA YELLOW BLACK Technical Specifications Technical Specifications continued MODEL SELECTOR GUIDE MAIN OUTPUT(S) Output Range: MODEL MAIN OUTPUT(S) LOGIC OUTPUT INTERFACES GPIB PL310 0 - 32V at 0 - 1A PL320 0 - 32V at 0 - 2A PL154 0 - 15.5V at 0 - 4A PL330 0 - 32V at 0 - 3A PL310QMD 2 x 0 - 32V at 0 - 1A ARC Output Voltage Setting: Output Current Setting: Output Mode: or 0 - 64V at 0 - 1A or 0 - ±32V at 0 - 1A 2 x 0 - 32V at 0 - 2A or 0 - 32V at 0 - 4A or 0 - 64V at 0 - 2A or 0 - ±32V at 0 - 2A PL330QMD 2 x 0 - 32V at 0 - 3A or 0 - 32V at 0 - 6A or 0 - 64V at 0 - 3A or 0 - ±32V at 0 - 3A PL310QMT 2 x 0 - 32V at 0 - 1A 5V at 1.5A or 0 - 32V at 0 - 2A or 0 - 64V at 0 - 1A or 0 - ±32V at 0 - 1A PL320QMT 2 x 0 - 32V at 0 - 2A LOGIC OUTPUT - PL310QMT 4 - 6V at 0.1 - 4A or 0 - 32V at 0 - 4A Output Voltage: Max.Output Current: Output Terminal: Output Protection: or 0 - 64V at 0 - 2A or 0 - ±32V at 0 - 2A PL330QMT 2 x 0 - 32V at 0 - 3A Load Regulation: Line Regulation: 4 - 6V at 0.1 - 7A or 0 - 32V at 0 - 6A By single logarithmic control. The power supply operates in constant current or constant voltage modes with automatic cross-over. Decimal points flash to indicate constant current mode. Isolated, True parallel, Series or Series Tracking via front panel switches. Configuration Selection: (QMD and QMT only) Output Switch: Isolates the output and permits voltage and current limits to be set up before connecting the load. Output Terminals: 4mm terminals on 19mm (0.75") spacing. Output Impedance: Constant Voltage: Typically <5mΩ at 1kHz Constant Current: Typically 50kΩ with voltage limit at maximum Output Protection: Up to maximum output voltage +20 Volts forward; diode clamped for reverse voltages and up to 3A reverse current. Load Regulation: <0.01% of maximum output for 90% load change Line Regulation: <0.01% of maximum output for 10% line voltage change Remote Sense: Eliminates up to 0.5V drop per lead. Ripple and Noise: Typically <1mV rms Transient Response: <20usec to within 50mV of setting for 90% load change Temperature Coefficient: Typically <100ppm/oC Meter Type: Dual 3.75 digit (4095 count) with 12.5mm (0.5") LEDS, (scale length increased to 8190 on PL330QMD/QMT). Reading rate 4 per second. Meter Resolution: Voltage: 10mV over the entire range Current: 1mA over the entire range Meter Accuracy: Voltage: ±(0.1% of reading + 1 digit) Current: ±(0.3% of reading + 1 digit) Current Meter Nominally 20ms switchable to 2 sec for averaging of rapidly Damping: varying loads or 0 - 32V at 0 - 2A PL320QMD 0 - 32 Volts nominal; 0 - 15.5V (PL154). 0 - 1.1A nominal (PL310); 0 - 2.1A nominal (PL320); 0 - 3.1A nominal (PL330); 0 - 4A nominal (PL154). By coarse and fine controls; resolution better than 5mV across the range. Fixed 5 V ± 0⋅1 V. >1⋅5 Amps. 4mm terminals on 19mm (0⋅75") spacing. Output will withstand up to 16 V forward voltage. Diode clamped for reverse voltages and up to 3 Amps reverse current. < 0⋅3% for 50% load change. < 0⋅1% for 10% line change. LOGIC OUTPUT - PL320QMT or 0 - 64V at 0 - 3A or 0 - ±32V at 0 - 3A PL330P 0 - 32V at 0 - 3A Yes Yes PL330DP 2 x 0 - 32V at 0 - 3A Yes Yes PL330TP 2 x 0 - 32V at 0 - 3A Yes Yes 4 - 6V at 1 - 7A Models illustrated within this brochure:Front cover - PL330, PL320QMD, PL310QMT Inside pages - PL330QMT, PL330DP Output Voltage Range: Output Current: Output Switch: Output Terminals: Over-Voltage Protection: Output Protection: 4 to 6 Volts 0.1 to 4 Amps. Isolates the output and permits output voltage to be set before connecting the load. 4mm terminals on 19mm (0.75") spacing. Above 7 Volts Clamped by the over-voltage protection circuit for forward voltages over 7 Volts and up to 1 Amp forward current. Diode clamped for reverse voltages and up to 3 Amps reverse current. Load Regulation: <0.01% of maximum output for 90% load change Line Regulation: <0.01% of maximum output for 10% line voltage change Remote Sense: Eliminates up to 0.5V drop per lead. Ripple and Noise: Typically <1mV rms Transient Response: <20usec to within 50mV of setting for 90% load change Temperature Coefficient: Typically <100ppm/oC Voltage Setting Accuracy: ± 0.1V LOGIC OUTPUT - PL330QMT & PL330TP Output Voltage Range: Output Current: Output Switch: Output Terminals: Over-Voltage Protection: Output Protection: 4 to 6 Volts 0.1 to 7 Amps. Isolates the output and permits output voltage to be set before connecting the load. 4mm terminals on 19mm (0.75") spacing. Above 7 Volts Clamped by the over-voltage protection circuit for forward voltages over 7 Volts and up to 1 Amp forward current. Diode clamped for reverse voltages and up to 3 Amps reverse current. Load Regulation: <0.01% of maximum output for 90% load change Line Regulation: <0.01% of maximum output for 10% line voltage change Remote Sense: Eliminates up to 0.5V drop per lead. Ripple and Noise: Typically <1mV rms Transient Response: <20usec to within 50mV of setting for 90% load change Temperature Coefficient: Typically <100ppm/oC Meter Type: 3.75 digit (4095 count) with 12.5mm (0.5") LEDs. Reading rate 4 per second. Meter Resolution: Voltage: 10mV Current: 10mA Meter Accuracy: PL-P MODELS, ADDITIONAL SPECIFICATIONS MAIN OUTPUT(S) - REMOTE OPERATION 12 bit resolution (10mV steps) 12 bit resolution (1mA steps) Voltage: ±(0.1% + 10mV) Current: ±(0.2% + 2mA) Output Switch: Electronic by interface command (front panel output switches must be set to ON) Readback Resolution:Voltage: 10mV over the entire range Current: 1mA over the entire range Readback Accuracy: Voltage: ±(0.1% of reading + 1 digit) Current: ±(0.3% of reading + 1 digit) Current Meter Nominally 20ms switchable to 2 sec and back by remote Damping: commands PL & PL-P Series GENERAL Environmental: Weight: Internally set for 110, 120, 220 or 240VAC 50/60Hz ±10% of voltage setting Single Dual Triple 30V/1A 75VA 150VA 300VA 15V/4A & 30V/2A150VA 300VA 450VA 30V/3A 225VA 450VA 600VA Operating Range: 5oC to 40oC, 20% to 80% RH Storage Range: -20oC to +60oC Single Dual Triple 30V/1A PL 4.0kg 8.0kg 11.5kg 15V/4A PL 5.0kg 30V/2A PL 5.0kg 9.5kg 13.5kg 30V/3A PL 6.0kg 12.0kg 15.5kg 30V/3A PL-P 6.5kg 12.5kg 16.0kg Size: PL310, PL154, & PL320: 155mm(W) x 170mm(H) x 265mm(D) PL330: 155mm(W) x 170mm(H) x 300mm(D) PL330P: 207mm(W) x 170mm(H) x 300mm(D) PL310QMD, PL310QMT, & PL320QMD: 350mm(W) x 170mm(H) x 265mm(D) PL330QMD, & PL330DP: 350mm(W) x 170mm(H) x 300mm(D) PL320QMT: 425mm(W) x 170mm(H) x 265mm(D) PL330QMT, & PL330TP: 425mm(W) x 170mm(H) x 300mm(D) Rack Mount Option: 19 inch 4U mount for two PL330P or one PL330DP/TP. Anti-tamper cover for security. Electrical Safety: Designed and manufactured to comply with IEC 348 and IEC1010-1. Full safety sockets available to special order. EMC: Designed and manufactured to comply with EN50081–1 and EN50082–1. Laboratory Power Supplies LOGIC OUTPUT (PL330TP) - REMOTE OPERATION Standard and Programmable models, 35 watts to 240 watts Output Voltage Range: Output Current: Setting Accuracy: Output Switch: 4 to 6 Volts in 10mV steps 1 to 7 Amps in approximate 1A steps Voltage: ±(0.2% + 10mV) Electronic by interface command (front panel output switch must be set to ON) Readback Resolution:Current: 10mA Readback Accuracy: Current: ±(0.5% of reading + 1 digit ) THURLBY THANDAR INSTRUMENTS Power Requirements: Input Voltage: Input Voltage Range: Power Consumption: Voltage: ±(0.2% of reading + 1 digit ) Current: ±(0.5% of reading + 1 digit ) Remote programmable versions in the range feature full control, read back and status reporting via the GPIB and RS232 interfaces. The GPIB interface conforms to the IEEE 488.1 and 488.2 standards and the RS232 interface is fully compatible with the Thurlby-Thandar Addressable RS232 Chain (ARC) standard. 8 rear panel DIP switches are used to specify baud rate, bus address and active interface (GPIB or RS232). Remote/Local operation is selected by a front panel switch. LOCAL OPERATION For a programmable instrument operated in local state, all capabilities and specifications remain unchanged from those of a standard instrument . REMOTE OPERATION With the instrument switched to the remote state, all voltage and current adjustment controls become inoperative and commands received over the active interface will be parsed and executed. Output Voltage Setting: Output Current Setting: Setting Accuracy: REMOTE CONTROL INTERFACES - PL-P MODELS Both interfaces feature full control, readback and status reporting. RS232: Variable Baud rate (9600 maximum), 9 pin D-connector (female). Fully compatible with ARC (Addressable RS232 Chain) system. GPIB: Conforming with IEEE-488.1 and IEEE-488.2 Address Selection: By rear panel DIP switch. Remote/Local Operation: Selected by front panel switch. Remote Command Response Time: Interface: <15 ms (single command, input buffer empty). Output Voltage - Up:Time constant typically 2ms, e.g. 10ms to settle within 1% of a step change, 15ms to settle within 0.1%. Output Voltage - Down: Time constant determined by the discharge of the power supply output capacitor (47uF). Typically <10ms to settle within 1% for a 10V step change at 50mA load current; typically <200ms to settle within 1% at zero load. Output Current: Typically 50ms to settle within 10mA for a 1A change. Thurlby Thandar Instruments Ltd. operates a policy of continuous development and reserves the right to alter specifications without prior notice. Designed and built in the U.K. by: Thurlby Thandar Instruments Ltd. Glebe Road, Huntingdon. Cambs. PE18 7DX England Tel: 01480 412451 Fax: 01480 450409 e-mail: [email protected] 82100-0046 CYAN MAGENTA YELLOW BLACK Thurlby Thandar PL-P series programmable power at surprisingly low cost Thurlby Thandar PL series the Premier range of laboratory power supplies Precision with convenience The Thurlby Thandar PL series of laboratory bench power supplies has established itself in many countries as the “premier” range. High resolution controls enable precise setting of voltage and current levels whilst high accuracy digital meters provide clear, unambiguous readings. All of the many features of these PSUs have been carefully designed to give the user not just greater precision, but greater clarity, more control and unrivalled ease of use. The range has now been improved and extended to offer even better performance and choice. Greater resolution and control The PL series sets the standard for simple and comprehensive control. Voltages are set with coarse and fine controls for speed with precision. Currents are set with a semi-logarithmic control for increased resolution at low current levels. The DC output switch enables voltage and current levels to be set before the load is connected. With the output switch “off” the the current limit set point is displayed. With the output switch “on” the actual output current flowing is displayed. This invaluable feature allows delicate circuits to be protected by accurately setting the current limit level (down to a few milliamps if necessary) before connecting the circuit under test. Safety and protection PL series PSUs are designed and built to meet the stringent requirements of IEC348 and IEC1010. All outputs are fully protected against short circuit, reverse voltage and reverse currents. PL series units incorporate digital meters with a 3.75 digit scale length (4095 counts) to provide greater accuracy and resolution than other PSUs. Large and bright LEDs give a clear and unambiguous reading. An update rate of 4 per second provides near instantaneous response. Separate meters are used for voltage and current, eliminating the need for meter function switches with their attendant problems of misinterpretation. A damping switch for the current meter simplifies measurements on rapidly varying loads. PL series units incorporate integrated band-gap reference diodes as the basis for stabilisation of both voltage and current. Remote sense terminals enable the precision to be maintained at high currents by eliminating the effects of connection lead resistance. Without remote sense lead resistance of just a few tens of milliohms can seriously degrade regulation and produce misleading results. (Two cables of 0.05Ω each will drop a total of 0.3V at 3 Amps.) PL-P series The 32V-1A, 32V-2A and 32V-3A supplies are each available as a dual unit incorporating push button selection of four different modes of operation. The Thurlby Thandar PL-P series offers a high performance fully programmable power supply system at low cost. Based around the 32V-3A versions of the standard PL series, the PL-P models include single, dual and triple output units suitable for bench or rack mounting. When not connected to the bus, these PSUs can be operated exactly as a standard PL series PSU. Isolated True Parallel Completely independent operation of each supply. Converts the Master unit into a 2 Amp, 4 Amp or 6 Amp supply respectively. GPIB and RS-232 (ARC) interfaces Digital accuracy and convenience Remote sense for precision at high currents Quad-Mode Dual versions Series Series Tracking Internal linking of the two supplies providing up to 64 Volts. The Master unit voltage control sets up equal voltages on both supplies. Quad Mode Triple versions ● ● ● ● ● ● ● ● ● ● ● Simultaneous digital metering of voltage and current. True constant voltage or constant current operation. Twin 3.75 digit meters with large LED displays. 0.1% accuracy; 0.01 Volts and 0.001 Amps resolution. Excellent stability, resolution and setting accuracy. DC output switches, automatic mode indication. Precise control and monitoring of current limit settings. Remote sense facility for high-current precision. Current meter damping switch for fluctuating currents. Parallel and tracking modes on QMD & QMT models. High current “logic supply” output on QMT models. A wide range of models The PL series includes single, dual and triple output models from 35 Watts up to 240 Watts. See the model selector guide for a summary of voltage and current combinations. The PL series is part of a wider range of bench PSUs from Thurlby Thandar which includes models with current capabilities up to 20 Amps. Each of the quad-mode dual models is alternatively available as a triple supply incorporating one further independent output. This is a higher current 5 Volt output intended for powering logic circuits. The current rating and sophistication of the logic output varies according to the model as follows: PL310QMT Fixed 5V supply at 1.5A maximum. Full short-circuit protection. PL320QMT Variable output voltage (4V to 6V) and variable current limit (0.1A to 4A). Calibrated voltage control. Remote sense terminals, DC output switch, over-voltage trip. PL330QMT Variable output voltage (4V to 6V) and variable current limit (0.1A to 7A). Digital meter for current measurement and voltage setting. Remote sense terminals, DC output switch, over-voltage trip. Each PL-P series supply is fitted with both a GPIB (IEEE-488) interface and an ARC (addressable RS232) interface as standard. Both interfaces provide full bus control of voltage and current settings along with full readback of actual current and voltage levels. The GPIB interface conforms fully with IEEE-488.2 as well as IEEE-488.1. The ARC interface can be used as a conventional RS-232 interface or as part of a multi-instrument ARC system. On dual and triple output models a single bus address controls all outputs. Simple and consistent control PL-P series supplies use simple and consistent command structures which make programming particularly easy regardless of which interface is used. A National Instruments LabWindows* device driver is available as an option. ARC, an exclusive Thurlby Thandar innovation ARC stands for “Addressable RS-232 Chain” and is a low-cost system for linking instruments together so that they can be controlled and monitored by a personal computer. The ARC interface is an extension of the industry standard RS-232 interface and is exclusive to Thurlby-Thandar instruments. It differs from conventional RS-232 in that it allows multiple instruments (up to 32) to be controlled using the normal RS-232 or RS-422/423 port of a PC. ARC provides a low-cost alternative to GPIB which utilises lower cost instruments, inexpensive cables, and can be controlled by any personal computer without the need for a special interface card or special software. * LabWindows is a trademark of National Instruments Corporation. Fully isolated outputs for maximum flexibility Each output is fully floating and is optoisolated from the bus interfaces. Outputs can be linked in series or parallel to produce higher voltages or higher currents as required. High resolution control and readback Voltage and current levels can be set via the bus to a resolution of 10mV and 1mA for each main output. The 7 Amp logic output of the PL330TP can also be set to a resolution of 10mV but the current control resolution is limited to 1 Amp steps. Each main output can be read back via the bus to a resolution of 10mV and 1mA. ● ● ● ● ● ● ● Full bus control and readback of voltage and current. GPIB interface conforms to IEEE-488.2. ARC (Addressable RS-232) interface for low-cost PC based control. Can be operated as a conventional bench PSU. Single, dual and triple output models available. Triple output model incorporates fully controllable high current logic output. Rack mounting kit (4U) available for all models. CYAN MAGENTA YELLOW BLACK Thurlby Thandar PL-P series programmable power at surprisingly low cost Thurlby Thandar PL series the Premier range of laboratory power supplies Precision with convenience The Thurlby Thandar PL series of laboratory bench power supplies has established itself in many countries as the “premier” range. High resolution controls enable precise setting of voltage and current levels whilst high accuracy digital meters provide clear, unambiguous readings. All of the many features of these PSUs have been carefully designed to give the user not just greater precision, but greater clarity, more control and unrivalled ease of use. The range has now been improved and extended to offer even better performance and choice. Greater resolution and control The PL series sets the standard for simple and comprehensive control. Voltages are set with coarse and fine controls for speed with precision. Currents are set with a semi-logarithmic control for increased resolution at low current levels. The DC output switch enables voltage and current levels to be set before the load is connected. With the output switch “off” the the current limit set point is displayed. With the output switch “on” the actual output current flowing is displayed. This invaluable feature allows delicate circuits to be protected by accurately setting the current limit level (down to a few milliamps if necessary) before connecting the circuit under test. Safety and protection PL series PSUs are designed and built to meet the stringent requirements of IEC348 and IEC1010. All outputs are fully protected against short circuit, reverse voltage and reverse currents. PL series units incorporate digital meters with a 3.75 digit scale length (4095 counts) to provide greater accuracy and resolution than other PSUs. Large and bright LEDs give a clear and unambiguous reading. An update rate of 4 per second provides near instantaneous response. Separate meters are used for voltage and current, eliminating the need for meter function switches with their attendant problems of misinterpretation. A damping switch for the current meter simplifies measurements on rapidly varying loads. PL series units incorporate integrated band-gap reference diodes as the basis for stabilisation of both voltage and current. Remote sense terminals enable the precision to be maintained at high currents by eliminating the effects of connection lead resistance. Without remote sense lead resistance of just a few tens of milliohms can seriously degrade regulation and produce misleading results. (Two cables of 0.05Ω each will drop a total of 0.3V at 3 Amps.) PL-P series The 32V-1A, 32V-2A and 32V-3A supplies are each available as a dual unit incorporating push button selection of four different modes of operation. The Thurlby Thandar PL-P series offers a high performance fully programmable power supply system at low cost. Based around the 32V-3A versions of the standard PL series, the PL-P models include single, dual and triple output units suitable for bench or rack mounting. When not connected to the bus, these PSUs can be operated exactly as a standard PL series PSU. Isolated True Parallel Completely independent operation of each supply. Converts the Master unit into a 2 Amp, 4 Amp or 6 Amp supply respectively. GPIB and RS-232 (ARC) interfaces Digital accuracy and convenience Remote sense for precision at high currents Quad-Mode Dual versions Series Series Tracking Internal linking of the two supplies providing up to 64 Volts. The Master unit voltage control sets up equal voltages on both supplies. Quad Mode Triple versions ● ● ● ● ● ● ● ● ● ● ● Simultaneous digital metering of voltage and current. True constant voltage or constant current operation. Twin 3.75 digit meters with large LED displays. 0.1% accuracy; 0.01 Volts and 0.001 Amps resolution. Excellent stability, resolution and setting accuracy. DC output switches, automatic mode indication. Precise control and monitoring of current limit settings. Remote sense facility for high-current precision. Current meter damping switch for fluctuating currents. Parallel and tracking modes on QMD & QMT models. High current “logic supply” output on QMT models. A wide range of models The PL series includes single, dual and triple output models from 35 Watts up to 240 Watts. See the model selector guide for a summary of voltage and current combinations. The PL series is part of a wider range of bench PSUs from Thurlby Thandar which includes models with current capabilities up to 20 Amps. Each of the quad-mode dual models is alternatively available as a triple supply incorporating one further independent output. This is a higher current 5 Volt output intended for powering logic circuits. The current rating and sophistication of the logic output varies according to the model as follows: PL310QMT Fixed 5V supply at 1.5A maximum. Full short-circuit protection. PL320QMT Variable output voltage (4V to 6V) and variable current limit (0.1A to 4A). Calibrated voltage control. Remote sense terminals, DC output switch, over-voltage trip. PL330QMT Variable output voltage (4V to 6V) and variable current limit (0.1A to 7A). Digital meter for current measurement and voltage setting. Remote sense terminals, DC output switch, over-voltage trip. Each PL-P series supply is fitted with both a GPIB (IEEE-488) interface and an ARC (addressable RS232) interface as standard. Both interfaces provide full bus control of voltage and current settings along with full readback of actual current and voltage levels. The GPIB interface conforms fully with IEEE-488.2 as well as IEEE-488.1. The ARC interface can be used as a conventional RS-232 interface or as part of a multi-instrument ARC system. On dual and triple output models a single bus address controls all outputs. Simple and consistent control PL-P series supplies use simple and consistent command structures which make programming particularly easy regardless of which interface is used. A National Instruments LabWindows* device driver is available as an option. ARC, an exclusive Thurlby Thandar innovation ARC stands for “Addressable RS-232 Chain” and is a low-cost system for linking instruments together so that they can be controlled and monitored by a personal computer. The ARC interface is an extension of the industry standard RS-232 interface and is exclusive to Thurlby-Thandar instruments. It differs from conventional RS-232 in that it allows multiple instruments (up to 32) to be controlled using the normal RS-232 or RS-422/423 port of a PC. ARC provides a low-cost alternative to GPIB which utilises lower cost instruments, inexpensive cables, and can be controlled by any personal computer without the need for a special interface card or special software. * LabWindows is a trademark of National Instruments Corporation. Fully isolated outputs for maximum flexibility Each output is fully floating and is optoisolated from the bus interfaces. Outputs can be linked in series or parallel to produce higher voltages or higher currents as required. High resolution control and readback Voltage and current levels can be set via the bus to a resolution of 10mV and 1mA for each main output. The 7 Amp logic output of the PL330TP can also be set to a resolution of 10mV but the current control resolution is limited to 1 Amp steps. Each main output can be read back via the bus to a resolution of 10mV and 1mA. ● ● ● ● ● ● ● Full bus control and readback of voltage and current. GPIB interface conforms to IEEE-488.2. ARC (Addressable RS-232) interface for low-cost PC based control. Can be operated as a conventional bench PSU. Single, dual and triple output models available. Triple output model incorporates fully controllable high current logic output. Rack mounting kit (4U) available for all models. CYAN MAGENTA YELLOW BLACK Thurlby Thandar PL-P series programmable power at surprisingly low cost Thurlby Thandar PL series the Premier range of laboratory power supplies Precision with convenience The Thurlby Thandar PL series of laboratory bench power supplies has established itself in many countries as the “premier” range. High resolution controls enable precise setting of voltage and current levels whilst high accuracy digital meters provide clear, unambiguous readings. All of the many features of these PSUs have been carefully designed to give the user not just greater precision, but greater clarity, more control and unrivalled ease of use. The range has now been improved and extended to offer even better performance and choice. Greater resolution and control The PL series sets the standard for simple and comprehensive control. Voltages are set with coarse and fine controls for speed with precision. Currents are set with a semi-logarithmic control for increased resolution at low current levels. The DC output switch enables voltage and current levels to be set before the load is connected. With the output switch “off” the the current limit set point is displayed. With the output switch “on” the actual output current flowing is displayed. This invaluable feature allows delicate circuits to be protected by accurately setting the current limit level (down to a few milliamps if necessary) before connecting the circuit under test. Safety and protection PL series PSUs are designed and built to meet the stringent requirements of IEC348 and IEC1010. All outputs are fully protected against short circuit, reverse voltage and reverse currents. PL series units incorporate digital meters with a 3.75 digit scale length (4095 counts) to provide greater accuracy and resolution than other PSUs. Large and bright LEDs give a clear and unambiguous reading. An update rate of 4 per second provides near instantaneous response. Separate meters are used for voltage and current, eliminating the need for meter function switches with their attendant problems of misinterpretation. A damping switch for the current meter simplifies measurements on rapidly varying loads. PL series units incorporate integrated band-gap reference diodes as the basis for stabilisation of both voltage and current. Remote sense terminals enable the precision to be maintained at high currents by eliminating the effects of connection lead resistance. Without remote sense lead resistance of just a few tens of milliohms can seriously degrade regulation and produce misleading results. (Two cables of 0.05Ω each will drop a total of 0.3V at 3 Amps.) PL-P series The 32V-1A, 32V-2A and 32V-3A supplies are each available as a dual unit incorporating push button selection of four different modes of operation. The Thurlby Thandar PL-P series offers a high performance fully programmable power supply system at low cost. Based around the 32V-3A versions of the standard PL series, the PL-P models include single, dual and triple output units suitable for bench or rack mounting. When not connected to the bus, these PSUs can be operated exactly as a standard PL series PSU. Isolated True Parallel Completely independent operation of each supply. Converts the Master unit into a 2 Amp, 4 Amp or 6 Amp supply respectively. GPIB and RS-232 (ARC) interfaces Digital accuracy and convenience Remote sense for precision at high currents Quad-Mode Dual versions Series Series Tracking Internal linking of the two supplies providing up to 64 Volts. The Master unit voltage control sets up equal voltages on both supplies. Quad Mode Triple versions ● ● ● ● ● ● ● ● ● ● ● Simultaneous digital metering of voltage and current. True constant voltage or constant current operation. Twin 3.75 digit meters with large LED displays. 0.1% accuracy; 0.01 Volts and 0.001 Amps resolution. Excellent stability, resolution and setting accuracy. DC output switches, automatic mode indication. Precise control and monitoring of current limit settings. Remote sense facility for high-current precision. Current meter damping switch for fluctuating currents. Parallel and tracking modes on QMD & QMT models. High current “logic supply” output on QMT models. A wide range of models The PL series includes single, dual and triple output models from 35 Watts up to 240 Watts. See the model selector guide for a summary of voltage and current combinations. The PL series is part of a wider range of bench PSUs from Thurlby Thandar which includes models with current capabilities up to 20 Amps. Each of the quad-mode dual models is alternatively available as a triple supply incorporating one further independent output. This is a higher current 5 Volt output intended for powering logic circuits. The current rating and sophistication of the logic output varies according to the model as follows: PL310QMT Fixed 5V supply at 1.5A maximum. Full short-circuit protection. PL320QMT Variable output voltage (4V to 6V) and variable current limit (0.1A to 4A). Calibrated voltage control. Remote sense terminals, DC output switch, over-voltage trip. PL330QMT Variable output voltage (4V to 6V) and variable current limit (0.1A to 7A). Digital meter for current measurement and voltage setting. Remote sense terminals, DC output switch, over-voltage trip. Each PL-P series supply is fitted with both a GPIB (IEEE-488) interface and an ARC (addressable RS232) interface as standard. Both interfaces provide full bus control of voltage and current settings along with full readback of actual current and voltage levels. The GPIB interface conforms fully with IEEE-488.2 as well as IEEE-488.1. The ARC interface can be used as a conventional RS-232 interface or as part of a multi-instrument ARC system. On dual and triple output models a single bus address controls all outputs. Simple and consistent control PL-P series supplies use simple and consistent command structures which make programming particularly easy regardless of which interface is used. A National Instruments LabWindows* device driver is available as an option. ARC, an exclusive Thurlby Thandar innovation ARC stands for “Addressable RS-232 Chain” and is a low-cost system for linking instruments together so that they can be controlled and monitored by a personal computer. The ARC interface is an extension of the industry standard RS-232 interface and is exclusive to Thurlby-Thandar instruments. It differs from conventional RS-232 in that it allows multiple instruments (up to 32) to be controlled using the normal RS-232 or RS-422/423 port of a PC. ARC provides a low-cost alternative to GPIB which utilises lower cost instruments, inexpensive cables, and can be controlled by any personal computer without the need for a special interface card or special software. * LabWindows is a trademark of National Instruments Corporation. Fully isolated outputs for maximum flexibility Each output is fully floating and is optoisolated from the bus interfaces. Outputs can be linked in series or parallel to produce higher voltages or higher currents as required. High resolution control and readback Voltage and current levels can be set via the bus to a resolution of 10mV and 1mA for each main output. The 7 Amp logic output of the PL330TP can also be set to a resolution of 10mV but the current control resolution is limited to 1 Amp steps. Each main output can be read back via the bus to a resolution of 10mV and 1mA. ● ● ● ● ● ● ● Full bus control and readback of voltage and current. GPIB interface conforms to IEEE-488.2. ARC (Addressable RS-232) interface for low-cost PC based control. Can be operated as a conventional bench PSU. Single, dual and triple output models available. Triple output model incorporates fully controllable high current logic output. Rack mounting kit (4U) available for all models. CYAN MAGENTA YELLOW BLACK Technical Specifications Technical Specifications continued MODEL SELECTOR GUIDE MAIN OUTPUT(S) Output Range: MODEL MAIN OUTPUT(S) LOGIC OUTPUT INTERFACES GPIB PL310 0 - 32V at 0 - 1A PL320 0 - 32V at 0 - 2A PL154 0 - 15.5V at 0 - 4A PL330 0 - 32V at 0 - 3A PL310QMD 2 x 0 - 32V at 0 - 1A ARC Output Voltage Setting: Output Current Setting: Output Mode: or 0 - 64V at 0 - 1A or 0 - ±32V at 0 - 1A 2 x 0 - 32V at 0 - 2A or 0 - 32V at 0 - 4A or 0 - 64V at 0 - 2A or 0 - ±32V at 0 - 2A PL330QMD 2 x 0 - 32V at 0 - 3A or 0 - 32V at 0 - 6A or 0 - 64V at 0 - 3A or 0 - ±32V at 0 - 3A PL310QMT 2 x 0 - 32V at 0 - 1A 5V at 1.5A or 0 - 32V at 0 - 2A or 0 - 64V at 0 - 1A or 0 - ±32V at 0 - 1A PL320QMT 2 x 0 - 32V at 0 - 2A LOGIC OUTPUT - PL310QMT 4 - 6V at 0.1 - 4A or 0 - 32V at 0 - 4A Output Voltage: Max.Output Current: Output Terminal: Output Protection: or 0 - 64V at 0 - 2A or 0 - ±32V at 0 - 2A PL330QMT 2 x 0 - 32V at 0 - 3A Load Regulation: Line Regulation: 4 - 6V at 0.1 - 7A or 0 - 32V at 0 - 6A By single logarithmic control. The power supply operates in constant current or constant voltage modes with automatic cross-over. Decimal points flash to indicate constant current mode. Isolated, True parallel, Series or Series Tracking via front panel switches. Configuration Selection: (QMD and QMT only) Output Switch: Isolates the output and permits voltage and current limits to be set up before connecting the load. Output Terminals: 4mm terminals on 19mm (0.75") spacing. Output Impedance: Constant Voltage: Typically <5mΩ at 1kHz Constant Current: Typically 50kΩ with voltage limit at maximum Output Protection: Up to maximum output voltage +20 Volts forward; diode clamped for reverse voltages and up to 3A reverse current. Load Regulation: <0.01% of maximum output for 90% load change Line Regulation: <0.01% of maximum output for 10% line voltage change Remote Sense: Eliminates up to 0.5V drop per lead. Ripple and Noise: Typically <1mV rms Transient Response: <20usec to within 50mV of setting for 90% load change Temperature Coefficient: Typically <100ppm/oC Meter Type: Dual 3.75 digit (4095 count) with 12.5mm (0.5") LEDS, (scale length increased to 8190 on PL330QMD/QMT). Reading rate 4 per second. Meter Resolution: Voltage: 10mV over the entire range Current: 1mA over the entire range Meter Accuracy: Voltage: ±(0.1% of reading + 1 digit) Current: ±(0.3% of reading + 1 digit) Current Meter Nominally 20ms switchable to 2 sec for averaging of rapidly Damping: varying loads or 0 - 32V at 0 - 2A PL320QMD 0 - 32 Volts nominal; 0 - 15.5V (PL154). 0 - 1.1A nominal (PL310); 0 - 2.1A nominal (PL320); 0 - 3.1A nominal (PL330); 0 - 4A nominal (PL154). By coarse and fine controls; resolution better than 5mV across the range. Fixed 5 V ± 0⋅1 V. >1⋅5 Amps. 4mm terminals on 19mm (0⋅75") spacing. Output will withstand up to 16 V forward voltage. Diode clamped for reverse voltages and up to 3 Amps reverse current. < 0⋅3% for 50% load change. < 0⋅1% for 10% line change. LOGIC OUTPUT - PL320QMT or 0 - 64V at 0 - 3A or 0 - ±32V at 0 - 3A PL330P 0 - 32V at 0 - 3A Yes Yes PL330DP 2 x 0 - 32V at 0 - 3A Yes Yes PL330TP 2 x 0 - 32V at 0 - 3A Yes Yes 4 - 6V at 1 - 7A Models illustrated within this brochure:Front cover - PL330, PL320QMD, PL310QMT Inside pages - PL330QMT, PL330DP Output Voltage Range: Output Current: Output Switch: Output Terminals: Over-Voltage Protection: Output Protection: 4 to 6 Volts 0.1 to 4 Amps. Isolates the output and permits output voltage to be set before connecting the load. 4mm terminals on 19mm (0.75") spacing. Above 7 Volts Clamped by the over-voltage protection circuit for forward voltages over 7 Volts and up to 1 Amp forward current. Diode clamped for reverse voltages and up to 3 Amps reverse current. Load Regulation: <0.01% of maximum output for 90% load change Line Regulation: <0.01% of maximum output for 10% line voltage change Remote Sense: Eliminates up to 0.5V drop per lead. Ripple and Noise: Typically <1mV rms Transient Response: <20usec to within 50mV of setting for 90% load change Temperature Coefficient: Typically <100ppm/oC Voltage Setting Accuracy: ± 0.1V LOGIC OUTPUT - PL330QMT & PL330TP Output Voltage Range: Output Current: Output Switch: Output Terminals: Over-Voltage Protection: Output Protection: 4 to 6 Volts 0.1 to 7 Amps. Isolates the output and permits output voltage to be set before connecting the load. 4mm terminals on 19mm (0.75") spacing. Above 7 Volts Clamped by the over-voltage protection circuit for forward voltages over 7 Volts and up to 1 Amp forward current. Diode clamped for reverse voltages and up to 3 Amps reverse current. Load Regulation: <0.01% of maximum output for 90% load change Line Regulation: <0.01% of maximum output for 10% line voltage change Remote Sense: Eliminates up to 0.5V drop per lead. Ripple and Noise: Typically <1mV rms Transient Response: <20usec to within 50mV of setting for 90% load change Temperature Coefficient: Typically <100ppm/oC Meter Type: 3.75 digit (4095 count) with 12.5mm (0.5") LEDs. Reading rate 4 per second. Meter Resolution: Voltage: 10mV Current: 10mA Meter Accuracy: PL-P MODELS, ADDITIONAL SPECIFICATIONS MAIN OUTPUT(S) - REMOTE OPERATION 12 bit resolution (10mV steps) 12 bit resolution (1mA steps) Voltage: ±(0.1% + 10mV) Current: ±(0.2% + 2mA) Output Switch: Electronic by interface command (front panel output switches must be set to ON) Readback Resolution:Voltage: 10mV over the entire range Current: 1mA over the entire range Readback Accuracy: Voltage: ±(0.1% of reading + 1 digit) Current: ±(0.3% of reading + 1 digit) Current Meter Nominally 20ms switchable to 2 sec and back by remote Damping: commands PL & PL-P Series GENERAL Environmental: Weight: Internally set for 110, 120, 220 or 240VAC 50/60Hz ±10% of voltage setting Single Dual Triple 30V/1A 75VA 150VA 300VA 15V/4A & 30V/2A150VA 300VA 450VA 30V/3A 225VA 450VA 600VA Operating Range: 5oC to 40oC, 20% to 80% RH Storage Range: -20oC to +60oC Single Dual Triple 30V/1A PL 4.0kg 8.0kg 11.5kg 15V/4A PL 5.0kg 30V/2A PL 5.0kg 9.5kg 13.5kg 30V/3A PL 6.0kg 12.0kg 15.5kg 30V/3A PL-P 6.5kg 12.5kg 16.0kg Size: PL310, PL154, & PL320: 155mm(W) x 170mm(H) x 265mm(D) PL330: 155mm(W) x 170mm(H) x 300mm(D) PL330P: 207mm(W) x 170mm(H) x 300mm(D) PL310QMD, PL310QMT, & PL320QMD: 350mm(W) x 170mm(H) x 265mm(D) PL330QMD, & PL330DP: 350mm(W) x 170mm(H) x 300mm(D) PL320QMT: 425mm(W) x 170mm(H) x 265mm(D) PL330QMT, & PL330TP: 425mm(W) x 170mm(H) x 300mm(D) Rack Mount Option: 19 inch 4U mount for two PL330P or one PL330DP/TP. Anti-tamper cover for security. Electrical Safety: Designed and manufactured to comply with IEC 348 and IEC1010-1. Full safety sockets available to special order. EMC: Designed and manufactured to comply with EN50081–1 and EN50082–1. Laboratory Power Supplies LOGIC OUTPUT (PL330TP) - REMOTE OPERATION Standard and Programmable models, 35 watts to 240 watts Output Voltage Range: Output Current: Setting Accuracy: Output Switch: 4 to 6 Volts in 10mV steps 1 to 7 Amps in approximate 1A steps Voltage: ±(0.2% + 10mV) Electronic by interface command (front panel output switch must be set to ON) Readback Resolution:Current: 10mA Readback Accuracy: Current: ±(0.5% of reading + 1 digit ) THURLBY THANDAR INSTRUMENTS Power Requirements: Input Voltage: Input Voltage Range: Power Consumption: Voltage: ±(0.2% of reading + 1 digit ) Current: ±(0.5% of reading + 1 digit ) Remote programmable versions in the range feature full control, read back and status reporting via the GPIB and RS232 interfaces. The GPIB interface conforms to the IEEE 488.1 and 488.2 standards and the RS232 interface is fully compatible with the Thurlby-Thandar Addressable RS232 Chain (ARC) standard. 8 rear panel DIP switches are used to specify baud rate, bus address and active interface (GPIB or RS232). Remote/Local operation is selected by a front panel switch. LOCAL OPERATION For a programmable instrument operated in local state, all capabilities and specifications remain unchanged from those of a standard instrument . REMOTE OPERATION With the instrument switched to the remote state, all voltage and current adjustment controls become inoperative and commands received over the active interface will be parsed and executed. Output Voltage Setting: Output Current Setting: Setting Accuracy: REMOTE CONTROL INTERFACES - PL-P MODELS Both interfaces feature full control, readback and status reporting. RS232: Variable Baud rate (9600 maximum), 9 pin D-connector (female). Fully compatible with ARC (Addressable RS232 Chain) system. GPIB: Conforming with IEEE-488.1 and IEEE-488.2 Address Selection: By rear panel DIP switch. Remote/Local Operation: Selected by front panel switch. Remote Command Response Time: Interface: <15 ms (single command, input buffer empty). Output Voltage - Up:Time constant typically 2ms, e.g. 10ms to settle within 1% of a step change, 15ms to settle within 0.1%. Output Voltage - Down: Time constant determined by the discharge of the power supply output capacitor (47uF). Typically <10ms to settle within 1% for a 10V step change at 50mA load current; typically <200ms to settle within 1% at zero load. Output Current: Typically 50ms to settle within 10mA for a 1A change. Thurlby Thandar Instruments Ltd. operates a policy of continuous development and reserves the right to alter specifications without prior notice. Designed and built in the U.K. by: Thurlby Thandar Instruments Ltd. Glebe Road, Huntingdon. Cambs. PE18 7DX England Tel: 01480 412451 Fax: 01480 450409 e-mail: [email protected] 82100-0046 CYAN MAGENTA YELLOW BLACK Technical Specifications Technical Specifications continued MODEL SELECTOR GUIDE MAIN OUTPUT(S) Output Range: MODEL MAIN OUTPUT(S) LOGIC OUTPUT INTERFACES GPIB PL310 0 - 32V at 0 - 1A PL320 0 - 32V at 0 - 2A PL154 0 - 15.5V at 0 - 4A PL330 0 - 32V at 0 - 3A PL310QMD 2 x 0 - 32V at 0 - 1A ARC Output Voltage Setting: Output Current Setting: Output Mode: or 0 - 64V at 0 - 1A or 0 - ±32V at 0 - 1A 2 x 0 - 32V at 0 - 2A or 0 - 32V at 0 - 4A or 0 - 64V at 0 - 2A or 0 - ±32V at 0 - 2A PL330QMD 2 x 0 - 32V at 0 - 3A or 0 - 32V at 0 - 6A or 0 - 64V at 0 - 3A or 0 - ±32V at 0 - 3A PL310QMT 2 x 0 - 32V at 0 - 1A 5V at 1.5A or 0 - 32V at 0 - 2A or 0 - 64V at 0 - 1A or 0 - ±32V at 0 - 1A PL320QMT 2 x 0 - 32V at 0 - 2A LOGIC OUTPUT - PL310QMT 4 - 6V at 0.1 - 4A or 0 - 32V at 0 - 4A Output Voltage: Max.Output Current: Output Terminal: Output Protection: or 0 - 64V at 0 - 2A or 0 - ±32V at 0 - 2A PL330QMT 2 x 0 - 32V at 0 - 3A Load Regulation: Line Regulation: 4 - 6V at 0.1 - 7A or 0 - 32V at 0 - 6A By single logarithmic control. The power supply operates in constant current or constant voltage modes with automatic cross-over. Decimal points flash to indicate constant current mode. Isolated, True parallel, Series or Series Tracking via front panel switches. Configuration Selection: (QMD and QMT only) Output Switch: Isolates the output and permits voltage and current limits to be set up before connecting the load. Output Terminals: 4mm terminals on 19mm (0.75") spacing. Output Impedance: Constant Voltage: Typically <5mΩ at 1kHz Constant Current: Typically 50kΩ with voltage limit at maximum Output Protection: Up to maximum output voltage +20 Volts forward; diode clamped for reverse voltages and up to 3A reverse current. Load Regulation: <0.01% of maximum output for 90% load change Line Regulation: <0.01% of maximum output for 10% line voltage change Remote Sense: Eliminates up to 0.5V drop per lead. Ripple and Noise: Typically <1mV rms Transient Response: <20usec to within 50mV of setting for 90% load change Temperature Coefficient: Typically <100ppm/oC Meter Type: Dual 3.75 digit (4095 count) with 12.5mm (0.5") LEDS, (scale length increased to 8190 on PL330QMD/QMT). Reading rate 4 per second. Meter Resolution: Voltage: 10mV over the entire range Current: 1mA over the entire range Meter Accuracy: Voltage: ±(0.1% of reading + 1 digit) Current: ±(0.3% of reading + 1 digit) Current Meter Nominally 20ms switchable to 2 sec for averaging of rapidly Damping: varying loads or 0 - 32V at 0 - 2A PL320QMD 0 - 32 Volts nominal; 0 - 15.5V (PL154). 0 - 1.1A nominal (PL310); 0 - 2.1A nominal (PL320); 0 - 3.1A nominal (PL330); 0 - 4A nominal (PL154). By coarse and fine controls; resolution better than 5mV across the range. Fixed 5 V ± 0⋅1 V. >1⋅5 Amps. 4mm terminals on 19mm (0⋅75") spacing. Output will withstand up to 16 V forward voltage. Diode clamped for reverse voltages and up to 3 Amps reverse current. < 0⋅3% for 50% load change. < 0⋅1% for 10% line change. LOGIC OUTPUT - PL320QMT or 0 - 64V at 0 - 3A or 0 - ±32V at 0 - 3A PL330P 0 - 32V at 0 - 3A Yes Yes PL330DP 2 x 0 - 32V at 0 - 3A Yes Yes PL330TP 2 x 0 - 32V at 0 - 3A Yes Yes 4 - 6V at 1 - 7A Models illustrated within this brochure:Front cover - PL330, PL320QMD, PL310QMT Inside pages - PL330QMT, PL330DP Output Voltage Range: Output Current: Output Switch: Output Terminals: Over-Voltage Protection: Output Protection: 4 to 6 Volts 0.1 to 4 Amps. Isolates the output and permits output voltage to be set before connecting the load. 4mm terminals on 19mm (0.75") spacing. Above 7 Volts Clamped by the over-voltage protection circuit for forward voltages over 7 Volts and up to 1 Amp forward current. Diode clamped for reverse voltages and up to 3 Amps reverse current. Load Regulation: <0.01% of maximum output for 90% load change Line Regulation: <0.01% of maximum output for 10% line voltage change Remote Sense: Eliminates up to 0.5V drop per lead. Ripple and Noise: Typically <1mV rms Transient Response: <20usec to within 50mV of setting for 90% load change Temperature Coefficient: Typically <100ppm/oC Voltage Setting Accuracy: ± 0.1V LOGIC OUTPUT - PL330QMT & PL330TP Output Voltage Range: Output Current: Output Switch: Output Terminals: Over-Voltage Protection: Output Protection: 4 to 6 Volts 0.1 to 7 Amps. Isolates the output and permits output voltage to be set before connecting the load. 4mm terminals on 19mm (0.75") spacing. Above 7 Volts Clamped by the over-voltage protection circuit for forward voltages over 7 Volts and up to 1 Amp forward current. Diode clamped for reverse voltages and up to 3 Amps reverse current. Load Regulation: <0.01% of maximum output for 90% load change Line Regulation: <0.01% of maximum output for 10% line voltage change Remote Sense: Eliminates up to 0.5V drop per lead. Ripple and Noise: Typically <1mV rms Transient Response: <20usec to within 50mV of setting for 90% load change Temperature Coefficient: Typically <100ppm/oC Meter Type: 3.75 digit (4095 count) with 12.5mm (0.5") LEDs. Reading rate 4 per second. Meter Resolution: Voltage: 10mV Current: 10mA Meter Accuracy: PL-P MODELS, ADDITIONAL SPECIFICATIONS MAIN OUTPUT(S) - REMOTE OPERATION 12 bit resolution (10mV steps) 12 bit resolution (1mA steps) Voltage: ±(0.1% + 10mV) Current: ±(0.2% + 2mA) Output Switch: Electronic by interface command (front panel output switches must be set to ON) Readback Resolution:Voltage: 10mV over the entire range Current: 1mA over the entire range Readback Accuracy: Voltage: ±(0.1% of reading + 1 digit) Current: ±(0.3% of reading + 1 digit) Current Meter Nominally 20ms switchable to 2 sec and back by remote Damping: commands PL & PL-P Series GENERAL Environmental: Weight: Internally set for 110, 120, 220 or 240VAC 50/60Hz ±10% of voltage setting Single Dual Triple 30V/1A 75VA 150VA 300VA 15V/4A & 30V/2A150VA 300VA 450VA 30V/3A 225VA 450VA 600VA Operating Range: 5oC to 40oC, 20% to 80% RH Storage Range: -20oC to +60oC Single Dual Triple 30V/1A PL 4.0kg 8.0kg 11.5kg 15V/4A PL 5.0kg 30V/2A PL 5.0kg 9.5kg 13.5kg 30V/3A PL 6.0kg 12.0kg 15.5kg 30V/3A PL-P 6.5kg 12.5kg 16.0kg Size: PL310, PL154, & PL320: 155mm(W) x 170mm(H) x 265mm(D) PL330: 155mm(W) x 170mm(H) x 300mm(D) PL330P: 207mm(W) x 170mm(H) x 300mm(D) PL310QMD, PL310QMT, & PL320QMD: 350mm(W) x 170mm(H) x 265mm(D) PL330QMD, & PL330DP: 350mm(W) x 170mm(H) x 300mm(D) PL320QMT: 425mm(W) x 170mm(H) x 265mm(D) PL330QMT, & PL330TP: 425mm(W) x 170mm(H) x 300mm(D) Rack Mount Option: 19 inch 4U mount for two PL330P or one PL330DP/TP. Anti-tamper cover for security. Electrical Safety: Designed and manufactured to comply with IEC 348 and IEC1010-1. Full safety sockets available to special order. EMC: Designed and manufactured to comply with EN50081–1 and EN50082–1. Laboratory Power Supplies LOGIC OUTPUT (PL330TP) - REMOTE OPERATION Standard and Programmable models, 35 watts to 240 watts Output Voltage Range: Output Current: Setting Accuracy: Output Switch: 4 to 6 Volts in 10mV steps 1 to 7 Amps in approximate 1A steps Voltage: ±(0.2% + 10mV) Electronic by interface command (front panel output switch must be set to ON) Readback Resolution:Current: 10mA Readback Accuracy: Current: ±(0.5% of reading + 1 digit ) THURLBY THANDAR INSTRUMENTS Power Requirements: Input Voltage: Input Voltage Range: Power Consumption: Voltage: ±(0.2% of reading + 1 digit ) Current: ±(0.5% of reading + 1 digit ) Remote programmable versions in the range feature full control, read back and status reporting via the GPIB and RS232 interfaces. The GPIB interface conforms to the IEEE 488.1 and 488.2 standards and the RS232 interface is fully compatible with the Thurlby-Thandar Addressable RS232 Chain (ARC) standard. 8 rear panel DIP switches are used to specify baud rate, bus address and active interface (GPIB or RS232). Remote/Local operation is selected by a front panel switch. LOCAL OPERATION For a programmable instrument operated in local state, all capabilities and specifications remain unchanged from those of a standard instrument . REMOTE OPERATION With the instrument switched to the remote state, all voltage and current adjustment controls become inoperative and commands received over the active interface will be parsed and executed. Output Voltage Setting: Output Current Setting: Setting Accuracy: REMOTE CONTROL INTERFACES - PL-P MODELS Both interfaces feature full control, readback and status reporting. RS232: Variable Baud rate (9600 maximum), 9 pin D-connector (female). Fully compatible with ARC (Addressable RS232 Chain) system. GPIB: Conforming with IEEE-488.1 and IEEE-488.2 Address Selection: By rear panel DIP switch. Remote/Local Operation: Selected by front panel switch. Remote Command Response Time: Interface: <15 ms (single command, input buffer empty). Output Voltage - Up:Time constant typically 2ms, e.g. 10ms to settle within 1% of a step change, 15ms to settle within 0.1%. Output Voltage - Down: Time constant determined by the discharge of the power supply output capacitor (47uF). Typically <10ms to settle within 1% for a 10V step change at 50mA load current; typically <200ms to settle within 1% at zero load. Output Current: Typically 50ms to settle within 10mA for a 1A change. Thurlby Thandar Instruments Ltd. operates a policy of continuous development and reserves the right to alter specifications without prior notice. Designed and built in the U.K. by: Thurlby Thandar Instruments Ltd. Glebe Road, Huntingdon. Cambs. PE18 7DX England Tel: 01480 412451 Fax: 01480 450409 e-mail: [email protected] 82100-0046