ETC FX-101-CFC-A3P2

Product Data Sheet
FX-101
Frequency Translator
Features
• Output frequencies up to 77.760 MHz
• Jitter Generation OC-192 compliant
• Jitter transfer per GR-253-CORE
• Single 5.0 or 3.3 Vdc supply
• Locked to specified Input frequency, e.g. 8 kHz
• 1" X 0.8" X 0.2", Surface Mount (FR4base)
• Optional CMOS or PECL Output
Applications
• SONET / SDH / ATM
• DWDM / FDM
• DSL-PON Interconnects
• FEC (Forward Error Correction)
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 •Web: www.vectron.com
FX-101 Frequency Translator
Description
Vectron's FX-101 is a crystal based frequency translator
which is used to translate any input frequency such as 8
kHz, 1.544 MHz, 2.048 MHz, 19.440 MHz etc.to any specific frequency less than or equal to 77.76 MHz. The input
frequency does not have to be a 50/50% duty cycle and
as an example can be an 8 kHz signal with a logic high
"on time" of only 1us, such as a BITS clock. The FX-101
also has the ability to translate any of 1 to 4 different input
frequencies to one common output frequency, such as
input frequencies of 8 kHz and 1.544 MHz and 19.44 MHz
and any other frequency between 8 kHz and 170 MHz
translating them to an output frequency up to 77.76 MHz.
The "Input Frequency tracking capability" is the total
amount of input frequency deviation in which the FX-101
is guaranteed to track or translate. As an example, a typical input clock would be 8 kHz ±20 ppm.The FX-101 is
guaranteed to track at least ±50 ppm of error over temperature/aging/power supply and is more than twice what
most applications require. The PLL control voltage is
brought out through a 470K ohm resistor.This would allow
for the use of external circuitry (analog comparators or an
A/D converter plus a processor) to detect when the control voltage is getting close to the limits of the pull range.
Performance Characteristics
Parameter
Symbol
Min
C = 5 Vdc
D = 3.3 Vdc
Vcc
Vcc
1.544
4.75
3.15
A = HCMOS
A = HCMOS
Icc
CLKIN
CLKIN
0
0.7 (VCC)
-VOH
-Vcc-1.025
VOL
Rise / Fall Time (77.76 MHz)
OUTPUT,
A = HCMOS
VOL
tR /tF
--
Vcc-1.810
VOH, IOL = 50 uA
VOL, IOL = 50 uA
VOH
VOL
VCC-0.3
Rise / Fall Time (77.76 MHz/20% to 80%)
Output Symmetry,
Freq >62.208MHz and 3.3V
Jitter @ 77.76 MHz (rms 12 kHz to 20 MHz)
tR /tF
Sym
Sym
Output Frequencies
Supply Voltage,
Supply Current
Input Signal, “0”
Input Signal, “1”
OUTPUT,
VOH
F = Comp PECL
--
Typical
Max
Unit
77.76
5.25
3.45
MHz
Vdc
Vdc
45
70
0.2 (VCC)
5.5
mA
Vdc
Vdc
PECL
-Vcc-0.880
-Vdc
Vcc-1.620
2
--
Vdc
ns
--
5.00
3.30
0.5
HCMOS
1.4
45
40
0.5
Jitter @ 77.76 MHz (cycle to cycle method)
Jitter Transfer, GR-253-CORE sec 5.6.2.1.2
3
0.1
Vdc
Vdc
2.5
55
60
1
ns
%
%
ps
5
0.1
ps
dB
Input Frequency Tracking Capability
(Can translate Stratum 1,2,3,3E,4 or SONET Min)
Operating Temperature
Size
APR
±50
Temp Range C = 0°C to +70°C
Temp Range F = -40°C to +85°C
25.4 x 20.32 x 5.08 (1.0” x 0.8” x 0.20”)
ppm
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Web:www.vectron.com
FX-101 Frequency Translator
Outline Drawing
Pin Out
Pin
1
Symbol
CLKIN
Function
Input Frequency - The FX-101 series AC couples the input, this means the unit is capable of
handling HCMOS, LvHCMOS, PECL and LvPECL input signals.
(For Input Frequencies below 1 MHz only HCMOS and LvHCMOS are supported.)
2
3
GND
LD
(output)
4
Monitor
(Output)
Ground
Lock Detect
Logic “1” indicates a locked condition
Logic “0” indicates that no input signal is present or the input signal has moved out of the
lock range.
PLL/ VCXO control voltage
Under locked conditions, should be >0.3V and <3.0V for the 3.3 volt option or >0.5V and
<4.5V for the 5 volt option. Input frequency may be out of range if voltage exceeds these limits.
5
6
--NC
7
8
GND
Tri-state
&
Enable
Disable
9
Out
10
11
COut
NC
12
13
14
Select A
Select B
NC
15
16
GND
Vcc
Missing
No Connection
Ground
HCMOS
Logic "1" (or no connect) = Output enabled
Logic "0"
= Output in high impedance
PECL
Logic "1"
= Output disabled
Logic "0" (or no connect) = Output enabled
Output (PECL) or HCMOS
Complementary Output (PECL) or GND for HCMOS output option
No Connection
Do not Exceed Vcc
Do not Exceed Vcc
No Connection
Ground
Power Supply Voltage (5 Vdc or 3.3Vdc)
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Web: www.vectron.com
FX-101 Frequency Translator
Pad Layout
Recommended Reflow Profile
NOTE: The FX-100 series should not be subjected to a wash process that will immerse it in solvents. NO CLEAN is the recommended procedure. The FX-100 series has been designed for pick and place reflow soldering. The suggested reflow profile is shown above. The FX-100 series may be reflowed once, and should not be reflowed in the inverted position.
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Web: www.vectron.com
FX-101 Frequency Translator
Standard Shipping Method
The Standard ship method for volume production of the
FX-100 series is in a matrix tray. These trays are 100%
recyclable. The trays also offer the added feature that
they can be continuously feed into a pick-n-place
machine eliminating the down time required with tapen-reel.
Handling Precautions
Although protection circuitry has been designed into this
device, proper precautions should be taken to avoid
exposure to electrostatic discharge (ESD) during handling and mounting. VI employs a human-body model
(HBM) for ESD-susceptibility testing and protection
design evaluation.
ESD voltage thresholds are dependent on the circuit
parameters used to define the mode. The HBM ESD
threshold presented here was obtained by using parameters where resistance = 1500 ohms, capacitance =
100pf)
ESD Threshold Voltage
Model
Human Body (HBM)
Threshold
Unit
500
V min
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Web:www.vectron.com
FX-101 Frequency Translator
Typical Application
All components outside the dotted line box are user supplied components. This is just one possbile
configuration of the FX-101. For additional information about your specific needs, please contact our factory.
Output Load Configuration
*Note: VI highly recommends either a
linear regulator or bypass capacitors;
10 uF, 0.1 uF and a 100pF capacitor
would be typical.
All components outside the dotted line box are user supplied components
and/or connections. This is just one possible configuration of the FX-101.
For additional information about your specific needs please contact our Factory.
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 •Web:www.vectron.com
FX-101 Frequency Translator
FX-100 Series Selection Guide
FITS / MTBF Calculations
Per Bellcore TR-NWT-000332, GF @ +50ºC.
Typical - FX-101-DFC-A1P2
FITs = 291.38
MTBF (Hours) = 3,432, 000
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Web:www.vectron.com
FX-101 Frequency Translator
FAQ’s
Q: What are the different input frequencies that are available?
A: The FX-100 series is able to handle any input frequency between 8 kHz and 170 MHz.
(A list of standard frequencies is available on pages 9 and 10.)
Q: How many different input frequencies can a specific FX-101 accept?
A: Each FX-101 can be programmed to accept up to 4 different frequencies.
Q: If there is only one input pin, how can your unit accept 4 different frequencies?
A: The user is required to supply a multiplexer which would switch between the different input
frequencies.The multiplexers’ select pins would need to be sync’d to the select pins of the FX-101.
(See The Typical Application illustrated on page 6.)
Q: Can a single FX-101 handle an application for 4 input frequencies of 8 kHz, 19.44, 38.88 and 77.76 MHz
all being translated to 77.76 MHz, with the 77.76 MHz input being LvPECL and the others HCMOS?
A: Yes; since the FX-101 AC couples the input signal, this combination can be supported.
Q: What is the lock time for the FX-101?
A: The exact lock time will depend on the specific input frequency. It should be noted that in all cases
the lock time will be significantly less than 1 second.
Q: I asked for a FX-101-DFC-A2S2 with 19.44 and 155.52 MHz for the input frequencies and was given a
Source Control Drawing (SCD) number of FX-101-DFC-S5999 Why was a new number assigned?
A: Whenever there are multiple input frequencies, we need to assign a SCD for the unit so that we can
include a table indicating what the logic levels need to be on pins 12 and 13 to control the unit per
the correct input frequency.
Q: What are the exact jitter transfer specs that the FX-101 series meets?
A: The FX-101 meets the stringent jitter transfer specs in GR-253 for Category II jitter (Section 5.6.2.1.2)
for all OC-n levels.
Q: Does the output frequency need to be 77.76 MHz?
A: No, the output frequency can be any frequency between 1.544 MHz and 77.76 MHz.
(A list of standard frequencies is available on pages 9 and 10.)
Q: What type of noise on the supply line can the FX-101 suppress?
A: The FX-101 is designed to clean up noise on the Input Clock Signal, it is not designed to clean up
noisy power supplies. If excessive noise is present on the supply line it may degrade the output
jitter performance. Additional external filtering may be required. Please consult with your power
supply vendor on the best way to filter noise on your supply line.
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Web:www.vectron.com
FX-101 Frequency Translator
Evaluation Board
Ground
VCXO
Monitor
Supply
Voltage
PECL Load Voltage:
Vcc- 2V
Edge
Mount
SMA
3 Places
Input
Frequency
Output
Frequency
LED
Lights
Up
When
Locked
For FX-101 with PECL output
Place Connector in the
“0” position for Enable
“1” position Disable
(In disable position as shown)
Input
Freq.
f1
=
Select
A
B
0
0
f2
f3
=
0
1
=
1
0
f4
=
1
1
Evaluation boards are available upon request.
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Web:www.vectron.com
FX-101 Frequency Translator
Other Standard Input / Output Combinations
Input 1
Input 2
Input 3
Input 4
Output
8 kHz
19.44 MHz
----
----
1.544 MHz
8 kHz
----
----
----
37.056 MHz
1.544 MHz
2.048 MHz
----
----
51.84 MHz
19.44 MHz
77.76 MHz
----
----
51.84 MHz
8 kHz
----
----
----
65.536 MHz
65.536
----
----
----
65.536 MHz
2.048 MHz
19.44 MHz
----
----
77.76 MHz
8 kHz
1.544 MHz
2.048 MHz
19.44 MHz
77.76 MHz
19.44 MHz
20.8286 MHz
77.76 MHz
83.3143 MHz
77.76 MHz
The combinations above are just a small sample of
what is possible with the FX-101 series.
This series is capable of translating up and down in
frequency. Virtually all input frequencies between 8
kHz and 170 MHz can be supported.
The FX-101 uses Vectron International’s V-type VCXO
and as such can support any output frequency that is
available with the V-Type. A list of available output frequencies for the V-Type is provided below.
V-type Available Frequencies (MHz)
1.544
2.000
2.048
3.088
3.580
3.686
4.000
4.032
4.096
4.434
5.000
6.144
6.176
6.312
6.400
8.000
8.192
8.448
10.000
12.000
12.288
12.352
13.000
14.318
15.360
15.440
16.000
16.384
18.432
19.44
20.000
20.480
24.000
24.576
24.704
27.000
30.000
32.000
32.768
34.368
35.328
38.880
40.000
40.960
44.736
50.000
51.840
52.000
65.536
77.760
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Web:www.vectron.com
FX-101 Frequency Translator
Standard Frequencies
8 kHz
C
16.384 MHz
N
77.76 MHz
2
16 kHz
D
19.44 MHz
P
82.944 MHz
3 In only
64 kHz
E
20.48 MHz
R
112 MHz
4 In only
1.024 MHz
F
26.00 MHz
T
139.264 MHz
5 In only
1.544 MHz
H
27.00 MHz
W
155.52 MHz
6 In only
2.048 MHz
J
38.88 MHz
X
166.6286 MHz
7 In only
4.096 MHz
K
44.736 MHz
Y
8.192 MHz
L
51.84 MHz
0
13.00 MHz
M
61.44 MHz
1
Special SCD
S
How to Order
FX-101 -
D F
C
-
A
1
P
2
Supply Voltage
C = 5 Vdc ±5%
D = 3.3 Vdc ±5%
Output Type
A = HCMOS
F = Comp. PECL
Temperature Range
C = 0°C to +70°C
F = -40°C to +85°C
Output Frequency (H to 2)
See Frequency Chart Above
*If not listed enter S in this block and then list the
output frequencies after the part number.
Input Frequency (C to 7)
See Frequency Chart Above
*If not listed or more than one frequency enter S in
this block and then list all the input frequencies
after the part number.
Number of Input Frequencies
1 = 1 Input Frequency
2 = 2 Input Frequencies
3 = 3 Input Frequencies
4 = 4 Input Frequencies
Input Logic
A = HCMOS
*If not listed or more than one input frequency a
special SCD number will be assigned at point of order.
Part Number Examples:
*FX-101-DFC-A1P2
*FX-101-DFC-A4S2, S = 8 kHz, 1.544 MHz, 2.048 MHz, 19.44 MHz
*FX-101-CFC-A1CS, S = 65.536 MHz
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Web:www.vectron.com
FX-101 Frequency Translator
Visit Our Website at
www.vectron.com
For additional information please contact:
USA: Vectron International * 267 Lowell Road, Hudson, NH 03051........ Tel:1-88-VECTRON-1 * Fax:1-888-FAX-VECTRON
EUROPE: .................................................................................................Tel: 49 (0) 3328 4784 17 * Fax: 49 (0) 3328 4784 30
ASIA:.................................................................................Tel: +86 21 28909740 / 41 / 42 Fax: +86 21 28909240 / 28909999
...
www.vectron.com
I
Vectron International reser ves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Web:www.vectron.com