MAXIM DS21S07A

DS2109
DS2109
Plug and Play SCSI Terminator
FEATURES
• Fully
PIN ASSIGNMENT
compliant with SCSI–1, Fast SCSI and Ultra
SCSI
PDI
1
28
GND
R1
2
27
R18
R2
3
26
R17
R3
4
25
R16
R4
5
24
R15
R5
6
23
R14
HS–GND
7
22
TCS
HS–GND
8
21
HS–GND
PDO
9
20
PDE
R6
10
19
R13
• Low power down capacitance of 3 pF
R7
11
18
R12
• Onboard thermal shutdown circuitry
R8
12
17
R11
R9
13
16
R10
TPWR
14
15
VREF
• Compatible with Plug and Play SCSI Profile
• Functionally compatible with DS21S07A
• Provides active termination for 18 signal lines
• 2%
tolerance on termination resistors and voltage
regulator
• Bus termination sensing
DS2109, DS2109S 28–PIN SOIC (300 MIL)
DESCRIPTION
The DS2109 is intended for one chip Plug and Play
(PnP) SCSI termination. Plug and Play SCSI requires
the exit–point terminator on computer motherboards or
host bus adapters to automatically switch off if an external device is connected to the system. The DS2109 satisfies this requirement by offering the engineer a choice
of onboard current sensing circuitry or onboard ground
detect circuitry. If an external device is connected, the
DS2109 will automatically be isolated from the SCSI
bus thereby maintaining proper system termination.
The DS2109 integrates a low drop–out regulator, 18
precise switched 110 ohm termination resistors, and
bus termination sensors into a 28–pin 300 mil SOIC
package. Active termination provides: greater immunity to voltage drops on the TERMPWR (TERMination
PoWeR) line, enhanced high–level noise immunity,
intrinsic TERMPWR decoupling, and very low quiescent current consumption. The DS2109 contains an
output port that can control the power down pin of additional terminators (DS21S07A) for Wide SCSI applications.
022698 1/10
DS2109
REFERENCE DOCUMENTS
FUNCTIONAL DESCRIPTION
SCSI–2 (X3.131–1994)
SCSI–3 Parallel Interface (X3T10/855D)
Available from: Global Engineering Documents
15 Inverness Way East
Englewood, CO 80112–5704
Phone: (800) 854–7179,(303) 792–2181
Fax: (303) 792–2192
The DS2109 is designed to be a single chip termination
subsystem for use in PnP SCSI systems, Figure 1.
When embedded on a host bus adapter or motherboard, the DS2109 can automatically sense the termination status of the SCSI bus and attach or isolate its
resistors as needed to maintain proper bus termination.
External and internal active termination can be provided
by the DS21S07A.
PnP SCSI Specification
PnP ISA Specification
PnP BIOS Specification
PnP Option ROM Specification
Available from: Plug and Play forum on
CompuServe (Go plugplay).
DS2109 APPLICATION ENVIRONMENT Figure 1
PERIPHERAL
SUBSYSTEM
DS2109 AUTOMATIC
EXIT–POINT TERMINATOR
EXTERNAL
TERMINATOR
(TWO DS21S07A)
50–POSITION
HIGH DENSITY
CONNECTORS
HOST SCSI
PROTOCOL CHIP
SCSI
PERIPHERAL
DEVICES
SCSI EXTERNAL
CABLE
SCSI INTERNAL
CABLES
INTERNAL
TERMINATOR
(TWO DS21S07A)
022698 2/10
DS2109
The DS2109 consists of 3 major functional blocks,
Figure 2:
erly terminated without the DS2109, the power down
buffer isolates the resistors from the SCSI bus and disables the power amp, thereby placing the DS2109 in a
low power mode (the bus sensing circuitry always stays
active). The PDO (Power Down Output) pin can be connected to the pin of a DS21S07A SCSI terminator for
Wide SCSI configurations, Figure 8.
• Voltage reference, terminating resistors, and isolation
switches
• Bus current sensing circuitry
• Bus ground sensing circuity
When the Bus Ground Sensing Circuitry or Bus Current
Sensing Circuitry determine that the SCSI bus is prop-
DS2109 BLOCK DIAGRAM Figure 2
PDI
PDE
BUS GROUND
SENSING
CIRCUITRY
DISABLE
PDO
DISABLE
BUS CURRENT
SENSING
CIRCUITRY
TCS
POWER
DOWN
BUFFER
110 OHMS
BANDGAP
REFERENCE
R14
+
–
110 OHMS
R18
110 OHMS
R1
VREF
022698 3/10
DS2109
DETAILED PIN DESCRIPTION Table 1
PIN
SYMBOL
FCN
DESCRIPTION
1
PDI
I
Power Down Internal. For Bus Ground Sensing Circuit connect to pin 22
of internal SCSI connector, see Figure 4.
2–6,
10–13,
16–19,
24–27
R1...R13
R15...18
T
Signal Termination. 110 ohm termination. Connect to SCSI bus signal
lines. For Bus Current Sensing Circuit connect to data, parity, and control
lines, except SCSI–RST line, see Figure 6.
7, 8, 21
HS–GND
P
Heat Sink Ground. Internally connected to the mounting pad. Should be
either grounded or electronically isolated from other circuitry.
9
PDO
O
Power Down Output. Connect to DS21S07A for Wide SCSI applications, see Figure 8.
14
TPWR
P
Termination Power. Connect to the SCSI TERMPWR line. Bypass with
a 2.2 µF capacitor, see Figures 4 and 6.
15
VREF
O
Reference Voltage. 2.85 volt reference; must be decoupled with a 4.7 µF
capacitor, see Figures 4 and 6.
20
PDE
I
Power Down External. For Bus Ground Sensing Circuit, connect to pin
36 of external SCSI connector, see Figure 4.
22
TCS
I
Termination Current Sense. Used to sense current on the SCSI bus.
For Bus Current Sensing Circuit, connect to SCSI signal line –RST, see
Figure 6.
23
R14
T
Signal Termination. 110 ohm termination. Connect to SCSI bus signal
line. For Bus Current Sensing Circuit connect to SCSI controller chip, see
Figure 6.
28
GND
P
Ground. Signal ground; 0.0 volts.
ACTIVE TERMINATION
The voltage regulator circuitry (bandgap reference and
class AB power amplifier) produces a precise laser–
trimmed 2.85 volt level and is capable of sourcing 24 mA
into each of the terminating resistors when the signal
line is low (active). When the external driver for a given
signal line turns off, the active terminator will pull that
signal line to 2.85 volts (quiescent state). When used
with an active negation driver, the power amp can sink
22 mA per line while keeping the voltage reference in
regulation; the terminating resistors maintain their 110Ω
value over the entire voltage range. To maintain the specified regulation, a 4.7 µF capacitor is required between
the VREF pin and ground. A high frequency cap (0.1 µF
ceramic recommended) can also be placed on the VREF
pin in applications that use fast rise/fall time drivers. The
power down capacitance on terminating resistors
R1–R13 and R15–R18 is <4 pF; R14 is slightly higher
due to the bus current sensing circuitry.
The DS2109 can be removed from the SCSI bus by
using either of two automatic methods, Bus Ground
Sensing or Bus Current Sensing.
022698 4/10
As with all analog circuitry, the TERMPWR lines should
be bypassed locally. A 2.2 µF capacitor is recommended between TPWR and ground and placed as
close as possible to the DS2109. The DS2109 should
be placed as close as possible to the connector to minimize signal and power trace length, thereby resulting in
less input capacitance and reflections which can
degrade the bus signals.
BUS GROUND SENSING
If internal and external SCSI devices are connected to
the SCSI bus, the DS2109 will disconnect from the SCSI
bus according to the circuit in Figure 3. To utilize this
automatic disconnect method of bus sensing, configure
the DS2109 as shown in Figure 4. The PDI (Power
Down Internal) pin should be connected to pin 22 of the
internal SCSI connector, and the PDE (Power Down
External) connected to pin 36 of the external SCSI connector.
DS2109
BUS GROUND SENSING CIRCUIT Figure 3
PDI
DISABLE
PDE
BUS GROUND DETECT CONFIGURATION Figure 4
INTERNAL SCSI CONNECTOR
22
26
TERMPWR
38
2.2 µF
PDI
GND
36
PDE
TPWR
EXTERNAL SCSI
CONNECTOR
DS2109
VREF
4.7 µF
022698 5/10
DS2109
BUS CURRENT SENSING
The DS2109 has the capability to use current sensing to
determine if the SCSI bus is over– or under–terminated.
A series 1 ohm resistor between pads R14 and TCS is
inserted into the SCSI bus (preferably the –RST line)
and used to monitor the current when that line pulls low
(active, or “asserted” state). Based on the current measured, the DS2109 will disconnect or connect from the
SCSI bus. The configuration for this automatic isolation
technique is shown in Figure 6.
Figure 5 shows a simplified diagram of the sensing circuit. The voltage across the 1 ohm sense resistor is differentially amplified and converted into a single–ended
voltage with respect to ground. This is fed into a bank of
comparators and measured against a reference voltage. The circuit takes a measurement each time TCS is
driven below a 0.8 volts threshold and the outputs are
latched on the rising edge of TCS. If IBUS is greater than
32 mA, the DS2109 will be isolated from the SCSI bus. It
is recommended that the signal on TCS be asserted for
at least 25 msec to allow the signal (and comparator outputs) to settle into a known state. A timing diagram of the
sensing and latching operation is shown in Figure 7.
It is preferred that the –RST line be used for monitoring
the bus termination status because –RST is only
asserted during power up or during a major change in
bus configuration. Note that R14 will have a higher input
capacitance than the other lines because of the additional circuitry required for bus sensing.
The DS2109 will be isolated from the SCSI bus as
shown in Table 2.
BUS CURRENT SENSING CIRCUITRY Figure 5
TO SCSI CONTROLLER
FROM SCSI BUS (–RST)
R14
TCS
1 OHM
IBUS
110 OHM
– +
REF
DECODE
AND
LATCH
022698 6/10
DS2109
BUS CURRENT SENSE CONFIGURATION Figure 6
INTERNAL SCSI
CONNECTOR
26
40
38
TERMPWR
DS2109
R1
EXTERNAL SCSI
CONTROLLER
TPWR
2.2 µF
R13
R15
VREF
R18
45
TCS
4.7 µF
–RST
R14
GND
–RST
SCSI
CONTROLLER
BUS CURRENT SENSE TIMING DIAGRAM Figure 7
25 µs min
TCS
COMPARATORS
LATCH
022698 7/10
DS2109
DISCONNECT MODES Table 2
PDI
PDE
IBUS > 32 mA?
DS2109 ISOLATED
FROM SCSI BUS?
0
0
No
Isolated
0
1
No
Connected
1
0
No
Connected
1
1
No
Connected
0
0
Yes
Isolated
0
1
Yes
Isolated
1
0
Yes
Isolated
1
1
Yes
Isolated
NOTE: “1” denotes pin left open circuited.
WIDE SCSI CONFIGURATION Figure 8
TERMINATION POWER LINE
2.2 µF
TERMPWR1
1
16
PD
PDI
1
28
GND
R1
2
15
VREF2
R1
2
27
R18
R2
3
14
NC
R2
3
26
R17
R3
4
13
R9
R3
4
25
R16
R4
5
12
R8
R4
5
24
R15
R5
6
11
R7
R5
6
23
R14
VREF1
7
10
R6
HS–GND
7
22
TCS
GND
8
9
TERMPWR2
HS–GND
8
21
HS–GND
PDO
9
20
PDE
R6
10
19
R13
R7
11
18
R12
R8
12
17
R11
R9
13
16
R10
TPWR
14
15
VREF
DS21S07A 16–PIN SOIC (300 MIL)
4.7 µF
DS2109S 28–PIN SOIC (300 MIL)
022698 8/10
4.7 µF
DS2109
ABSOLUTE MAXIMUM RATINGS*
Voltage on Any Pin Relative to Ground
Operating Temperature
Storage Temperature
Soldering Temperature
–1.0V to +7.0V
0°C to 70°C
–55°C to +125°C
260°C for 10 seconds
* This is a stress rating only and functional operation of the device at these or any other conditions above those
indicated in the operation sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods of time may affect reliability.
RECOMMENDED OPERATING CONDITIONS
PARAMETER
(0°C to 70°C)
SYMBOL
MIN
TERMPWR Voltage
VTP
Logic 1
Logic 0
TYP
MAX
UNITS
4.00
5.25
V
VIH
2.0
VTP+0.3
V
1
VIL
–0.3
+0.8
V
1
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
ITP
ITP
10
500
14
mA
mA
2, 4
2, 5
IPD
1
2
mA
2, 3, 6
110
112
ohms
2, 3
°C
2
pF
pF
2, 3, 6, 7
2,3,6,7,8
µA
2, 12
µA
2, 9, 12
mA
10
mA
11
DC CHARACTERISTICS
PARAMETER
(0°C to 70°C)
TERMPWR Current
Power Down Current
Termination Resistance
RTERM
Die Thermal Shutdown
TSD
150
Power Down Termination
Capacitance
CPD
C14
3
8
Input Leakage High
IIH
Input Leakage Low
IIL
Output Current
IO
Bus Current Sense Trip Point
108
4.5
–1.0
1.0
4
IBCST
32
REGULATOR CHARACTERISTICS
PARAMETER
Output Voltage
NOTES
(0°C to 70°C)
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
VREF
2.79
2.85
2.91
V
2, 3
Drop Out Voltage
VDROP
0.75
1.0
V
4, 7
Line Regulation
LIREG
1.0
2.0
%
2, 5
Load Regulation
LOREG
1.3
3.0
%
2, 3
Current Limit
IL
700
mA
2
Sink Current
ISINK
400
mA
2
022698 9/10
DS2109
NOTES:
1. PDI, PDE, TCS
2. 4.00V < TERMPWR < 5.25V.
3. 0.0V < signal lines < 3.0V.
4. All signal lines = 0.0V.
5. All signal lines open.
6. Power down enabled.
7. Guaranteed by design; not production tested.
8. C14 slightly higher capacitance due to sensing circuitry.
9. Excluding PDI, PDE pins.
10. PDO output pin.
11. IBCST > 32 mA – disable termination.
12. Excluding PDE, PDI, R14, and TCS pins.
28–PIN SOIC (300 MIL)
PKG
28–PIN
DIM
MIN
MAX
A IN.
MM
0.094
2.39
0.105
2.67
A1 IN.
MM
0.004
0.102
0.012
0.30
A2 IN.
MM
0.089
2.26
0.095
2.41
b IN.
MM
0.013
0.33
0.020
0.51
C IN
MM
0.009
0.229
0.013
0.33
D IN.
MM
0.698
17.73
0.712
18.08
e IN.
MM
The chamfer on the body is optional. If it is not present, a terminal 1 identifier must be positioned so that 1/2 or more of its area
is contained in the hatched zone.
E1 IN.
MM
0.290
7.37
0.300
7.62
H IN
MM
0.398
10.11
0.416
10.57
L IN
MM
0.016
0.40
0.040
1.02
0°
8°
Θ
022698 10/10
0.050 BSC
1.27 BSC