SHARP GP2U05

GP2U05
Particulate Detectable High
Sensitivity Type Dust Sensor
GP2U05
■ Features
■ Outline Dimensions
(Unit : mm)
3
1. High sensitivity (Dust detection sensitivity : 1 V/(0.1 mg/m )
2. Particulates of low concentration can be detected.
Lowest detectable dust concentration : TYP. 0.05 mg/m 3
3. Popular type
2-R3
48
11
φ 10
1
2
3
4
5
2-24
2-8
2- φ 3.2 ± 0.1 hole
2-R4
(Dust passing hole)
■ Applications
65 ± 0.2
73.2
4
JAPAN SOLDERLESS
TERMINAL MSG. CO.
made connector (S5B-PH-SM)
2-2
31.2
1. Air cleaners
2. Air conditioners
29
Terminal connection
1 Frame GND
Hole for sensitivity adjustment VR
4 LED drive terminal
5 VCC
* Unspecified tolerance : ± 0.3 mm
■ Absolute Maximum Ratings
Parameter
Supply voltage
Input terminal voltage
Operating temperature
Storage temperature
Symbol
VCC
VLED
Topr
Tstg
Rating
- 0.3 to+15
- 0.3 to+15
- 10 to+65
- 20 to+80
2 Output terminal(Vo)
3 Signal GND
(Ta=25˚C)
Unit
V
V
˚C
˚C
Remarks
Open drain operation input
-
• Operating Supply Voltage
Symbol
VCC
Rating
12 ± 1.8
Unit
V
Remarks
-
■ Electro-optical Characteristics
Parameter
Detection sensitivity
Output voltage at no dust
Output voltage range
LED drive current
Dissipation current
Symbol
Conditions
*1 *2
K
*2
VOC
VOH
RL=4.7kΩ
ILED
LED terminal=0V,*2
*2
ICC
RL=
(Ta=25 ˚C,Vcc=5V)
MIN.
0.7
0.1
Vcc - 1.8
-
TYP.
1.0
1.0
15
12
MAX.
1.3
3.0
20
20
Unit
V/(0.1mg/m3)
V
V
mA
mA
*1 • Dust concentration shall be a value of the cigarette (MILD SEVEN) smoke concentration measured using the digital dust densitometer
(SHIBATA KAGAKU KOGYO CO. LTD. made P-5L2).
• Detection sensitivity K represents the change of output voltage when dust concentration changes by 0.1 mg/m 3.
*2 Input conditions (pulse drive conditions) to LED input terminal shall be as shown in the right drawing.
T=30ms
Vcc
Pw=0.4ms
R1
R3
R4
+
Tr
4
C1
LED
R2
GP2U05
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”
GP2U05
■ Internal Block Diagram
5 Vcc
Emitter
circuit
Detection window
Drive
circuit
4 LED drive terminal
3 Signal GND
Detector
circuit
Amp.
circuit
Amp.
circuit
Peak hold
circuit
2 Output terminal (Vo)
Sensitivity adjustment
Dust
1 Frame GND
(Note) Signal GND : GND of circuit system
Frame GND : Connect to the case (conductive resin).
The signal GND is not connected to the frame GND in the case
Fig. 1 Output Voltage vs. Dust Concentration
Fig. 2 Output Voltage vs. Supply Voltage
12
4.5
4
Output voltage VO (V)
Output voltage VO (V)
10
8
6
Conditions :
4
Per Electro-optical
3.5
3
State with reflective object inserted from
sensor outside and output voltage set to
Vo=3.5V (at Vcc=12V)(equivalent to
dust concentration of about 0.24 mg/m3)
2.5
1.5
1
No-dust state
Characteristics
2
0.5
0
0.2
0.4
0.6
0.8
1.0
Dust concentration (mg/m 3 )
3.5
Output voltage VO (V)
3
State with reflective object inserted from
sensor outside and output voltage set to
Vo=3.6V (at Ta=25˚C)(equivalent to
dust concentration of about 0.22 mg/m3)
1.5
1
No-dust state
0.5
- 10
0
10
20
30
40
50
Ambient temperature Ta (˚C )
11
12
13
14
Supply voltage Vcc (V)
Fig. 3 Output Voltage vs. Ambient Temperature
2.5
10
60
15