AD ADUM1280

3 kV RMS Dual Channel Digital Isolators
ADuM1280/ADuM1281/ADuM1285/ADuM1286
Data Sheet
FEATURES
GENERAL DESCRIPTION
Up to 100 Mbps data rate (NRZ)
Low propagation delay: 20 ns typical
Low dynamic power consumption
Bidirectional communication
3 V to 5 V level translation
High temperature operation: 125°C
High common-mode transient immunity: >25 kV/μs
Default high output: ADuM1280/ADuM1281
Default low output: ADuM1285/ADuM1286
Narrow body, RoHS-compliant, 8-lead SOIC
Safety and regulatory approvals (pending)
UL recognition: 3000 V rms for 1 minute per UL 1577
CSA Component Acceptance Notice #5A
VDE Certificate Of Conformity
DIN V VDE V 0884-10 (VDE V 0884-10): 2006-12
VIORM = 560 V peak
Qualified for automotive applications
The ADuM1280/ADuM1281/ADuM1285/ADuM12861 (also
referred to as ADuM128x in this data sheet) are dual-channel
digital isolators based on the Analog Devices, Inc., iCoupler®
technology. Combining high speed CMOS and monolithic air
core transformer technology, these isolation components
provide outstanding performance characteristics superior to
alternatives, such as optocoupler devices and other integrated
couplers.
APPLICATIONS
General-purpose multichannel isolation
Data converter isolation
Industrial field bus isolation
Hybrid electric vehicles, battery monitor, and motor drive
With propagation delay at 20 ns, pulse width distortion is less
than 2 ns for C grade. Channel-to-channel matching is tight at
5 ns for C grade. The two channels of the ADuM128x are
independent isolation channels and are available in two channel
configurations with three different data rates up to 100 Mbps
(see the Ordering Guide). Industrial grade models operate with
the supply voltage on either side ranging from 2.7 V to 5.5 V
while automotive grades operate from 3.0 V to 5.5 V, providing
compatibility with lower voltage systems as well as enabling a
voltage translation functionality across the isolation barrier.
Unlike other optocoupler alternatives, the ADuM128x isolators
have a patented refresh feature that ensures dc correctness in
the absence of input logic transitions. When power is first
applied or is not yet applied to the input side, the ADuM1280
and ADuM1281 have a default high output, and the ADuM1285
and ADuM1286 have a default low output.
For more information on safety and regulatory approvals, go to
http://www.analog.com/icouplersafety.
VDD1 1
ADuM1280/
ADuM1285
8
VDD2
VDD1 1
8
VDD2
ENCODE
DECODE
7
VOA
VOA 2
DECODE
ENCODE
7
VIA
VIB 3
ENCODE
DECODE
6
VOB
VIB 3
ENCODE
DECODE
6
VOB
5
GND2
5
GND2
10444-001
VIA 2
GND1 4
GND1 4
Figure 1. ADuM1280/ADuM1285
1
ADuM1281/
ADuM1286
10444-002
FUNCTIONAL BLOCK DIAGRAMS
Figure 2. ADuM1281/ADuM1286
Protected by U.S. Patents 5,952,849; 6,873,065; 6,903,578; and 7,075,329. Other patents are pending.
Rev. A
Document Feedback
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700 ©2012–2013 Analog Devices, Inc. All rights reserved.
Technical Support
www.analog.com
ADuM1280/ADuM1281/ADuM1285/ADuM1286
TABLE OF CONTENTS
Data Sheet
Features .....................................................................................1
Regulatory Information ....................................................... 10
Applications...............................................................................1
Insulation and Safety-Related Specifications ....................... 10
General Description ..................................................................1
DIN V VDE V 0884-10 (VDE V 0884-10): 2006-12
Insulation Characteristics .................................................... 11
Functional Block Diagrams .......................................................1
Revision History ........................................................................2
Specifications.............................................................................3
Electrical Characteristics—5 V Operation (All Grades).........3
Recommended Operating Conditions................................. 11
Absolute Maximum Ratings .................................................... 12
ESD Caution........................................................................ 12
Electrical Characteristics—3 V Operation (A, B, and C
Grades) ..................................................................................4
Pin Configurations and Function Descriptions....................... 13
Electrical Characteristics—Mixed 5 V/3 V Operation (A, B,
and C Grades) ........................................................................5
Applications Information ........................................................ 16
Electrical Characteristics—Mixed 3 V/5 V Operation (A, B,
and C Grades) ........................................................................6
Propagation Delay-Related Parameters................................ 16
Electrical Characteristics—3 V Operation (WA, WB, and WC
Grades) ..................................................................................7
Power Consumption............................................................ 17
Electrical Characteristics—Mixed 5 V/3 V Operation (WA,
WB, and WC Grades) ............................................................8
Electrical Characteristics—Mixed 3 V/5 V Operation (WA,
WB, and WC Grades) ............................................................9
Package Characteristics........................................................10
Typical Performance Characteristics ....................................... 15
PC Board Layout ................................................................. 16
DC Correctness and Magnetic Field Immunity ................... 16
Insulation Lifetime .............................................................. 18
Outline Dimensions ................................................................ 19
Ordering Guide ................................................................... 19
Automotive Products........................................................... 19
REVISION HISTORY
3/13—Rev. 0 to Rev. A
Changes to Features Section, Applications Section, and General
Description Section ...................................................................1
Added Table 13 to Table 21; Renumbererd Sequentially ............7
Changes to Table 26.................................................................11
Changes to Table 29 and Table 30 ............................................13
Changes to Ordering Guide .....................................................19
Added Automotive Products Section.......................................19
5/12—Revision 0: Initial Version
Rev. A | Page 2 of 20
Data Sheet
ADuM1280/ADuM1281/ADuM1285/ADuM1286
SPECIFICATIONS
ELECTRICAL CHARACTERISTICS—5 V OPERATION (ALL GRADES)
All typical specifications are at TA = 25°C, VDD1 = VDD2 = 5 V. Minimum/maximum specifications apply over the entire recommended
operation range: 4.5 V ≤ VDD1 ≤ 5.5 V, 4.5 V ≤ VDD2 ≤ 5.5 V, −40°C ≤ TA ≤ 125°C, unless otherwise noted. Switching specifications are
tested with CL = 15 pF and CMOS signal levels, unless otherwise noted.
Table 1.
Symbol
A, WA Grades
Min
Typ
Min
B, WB Grades
Min
Typ
Max
C, WC Grades
Min
Typ
Max
Pulse Width
Data Rate
Propagation Delay
PW
1000
40
10
Pulse Width Distortion
Change vs. Temperature
Propagation Delay Skew
tPSK
Channel Matching
Codirectional
tPSKCD
tPSKOD
Parameter
SWITCHING SPECIFICATIONS
Opposing Direction
tPHL, tPLH
1
50
25
35
PWD
10
3
7
18
2
3
Test Conditions
ns
Mbps
ns
ns
Within PWD limit
Within PWD limit
50% input to 50% output
12
9
ns
5
3
2
10
6
5
ns
ns
ns
2
2
|tPLH − tPHL|
ps/°C
1.5
38
Jitter
13
100
24
Unit
1
Between any two units at
same operating conditions
Table 2.
Parameter
SUPPLY CURRENT
ADuM1280/ADuM1285
ADuM1281/ADuM1286
Symbol
1 Mbps–A, B, C,WA, WB,
WC Grades
Min
Typ
Min
25 Mbps–B, C, WB,
WC Grades
Min
Typ
Max
100 Mbps–C, WC
Grades
Min
Typ
Max
Unit
20
9.5
15
15.6
mA
mA
mA
mA
Test Conditions
No load
IDD1
IDD2
IDD1
IDD2
1.1
2.7
2.1
2.3
1.6
4.5
2.6
2.9
6.2
4.8
4.9
4.7
7.0
7.0
6.0
6.4
25
15
19
19
Table 3. For All Models
Parameter
Symbol
Min
DC SPECIFICATIONS
Logic High Input Threshold
Logic Low Input Threshold
Logic High Output Voltages
VIH
VIL
VOH
0.7 VDDx
Logic Low Output Voltages
VOL
Input Current per Channel
Supply Current per Channel
Quiescent Input Supply Current
Quiescent Output Supply Current
Dynamic Input Supply Current
Dynamic Output Supply Current
Undervoltage Lockout
Positive VDDx Threshold
Negative VDDx Threshold
VDDx Hysteresis
II
AC SPECIFICATIONS
Output Rise/Fall Time
Common-Mode Transient Immunity1
Refresh Period
1
Typ
Max
0.3 VDDx
VDDx − 0.1
VDDx − 0.4
−10
5.0
4.8
0.0
0.2
+0.01
0.1
0.4
+10
Test Conditions
V
V
V
V
V
V
µA
IOx = −20 µA, VIx = VIxH
IOx = −4 mA, VIx = VIxH
IOx = 20 µA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
0 V ≤ VIx ≤ VDDx
IDDI(Q)
IDDO(Q)
IDDI(D)
IDDO(D)
0.54
1.6
0.09
0.04
VDDXUV+
VDDXUVVDDXUVH
2.6
2.4
0.2
V
V
V
2.5
35
ns
kV/µs
1.6
µs
tR/tF
|CM|
tr
25
0.8
2.0
Unit
mA
mA
mA/Mbps
mA/Mbps
10% to 90%
VIx = VDDx, VCM = 1000 V,
transient magnitude = 800 V
|CM| is the maximum common-mode voltage slew rate that can be sustained while maintaining Vo > 0.8 VDDx. The common-mode voltage slew rates apply to both
rising and falling common-mode voltage edges.
Rev. A | Page 3 of 20
ADuM1280/ADuM1281/ADuM1285/ADuM1286
Data Sheet
ELECTRICAL CHARACTERISTICS—3 V OPERATION (A, B, AND C GRADES)
All typical specifications are at TA = 25°C, VDD1 = VDD2 = 3.0 V. Minimum/maximum specifications apply over the entire recommended
operation range: 2.7 V ≤ VDD1 ≤ 3.6 V, 2.7 V ≤ VDD2 ≤ 3.6 V, −40°C ≤ TA ≤ 125°C, unless otherwise noted. Switching specifications are
tested with CL = 15 pF and CMOS signal levels, unless otherwise noted.
Table 4.
Parameter
Symbol
Min
SWITCHING SPECIFICATIONS
Pulse Width
Data Rate
PW
1000
A Grade
Typ
Min
Min
B Grade
Typ
Max
Min
40
C Grade
Typ
Max
10
1
25
50
10
35
3
Test Conditions
ns
Mbps
ns
ns
Within PWD limit
Within PWD limit
Propagation Delay
Pulse Width Distortion
tPHL, tPLH
PWD
Change vs. Temperature
Propagation Delay Skew
tPSK
38
16
12
ns
tPSKCD
tPSKOD
5
10
3
6
2.5
5
ns
ns
ns
7
20
100
33
Unit
25
2.5
3
50% input to 50% output
|tPLH − tPHL|
ps/°C
1.5
Between any two units at
same operating conditions
Channel Matching
Codirectional
Opposing-Direction
Jitter
2
2
1
7Codir ect ionalchannelm at chingis t heabs olut evalueof t hedif f er enceinpr opagat iondelays bet weenanyt wochannels wit hinput s ont hes am es ideof t heis olat ionbar r ier .Oppos ing- dir ect ionalchannelm at chingis t heabs olut evalueof t hedif f er enceinpr opagat iondelays bet weenanyt wochannels wit hinput s onoppos ings ides of t heis olat ionbar r ier .
Table 5.
Parameter
Symbol
SUPPLY CURRENT
ADuM1280/ADuM1285
IDD1
ADuM1281/ADuM1286
1 Mbps–A, B, C Grade
Min
Typ
Min
25 Mbps–B, C Grade
Min
Typ
Max
100 Mbps–C Grade
Min
Typ
Max
Unit
Test Conditions
No load
0.75
2.0
1.6
1.7
IDD2
IDD1
IDD2
1.4
5.1
2.7
3.8
3.9
3.5
2.1
2.3
9.0
4.6
5.0
6.2
17
4.8
11
11
23
9
15
15
mA
mA
mA
mA
Table 6. For All Models
Parameter
DC SPECIFICATIONS
Logic High Input Threshold
Logic Low Input Threshold
Logic High Output Voltages
Min
VIH
VIL
VOH
0.7 VDDx
Logic Low Output Voltages
VOL
Input Current per Channel
Supply Current per Channel
Quiescent Input Supply Current
Quiescent Output Supply Current
Dynamic Input Supply Current
Dynamic Output Supply Current
Undervoltage Lockout
Positive VDDx Threshold
Negative VDDx Threshold
VDDX Hysteresis
II
AC SPECIFICATIONS
Output Rise/Fall Time
Common-Mode Transient Immunity1
Refresh Period
1
Symbol
Typ
Max
0.3 VDDx
VDDx − 0.1
VDDx − 0.4
−10
3.0
2.8
0.0
0.2
+0.01
0.1
0.4
+10
Test Conditions
V
V
V
V
V
V
µA
IOx = −20 µA, VIx = VIxH
IOx = −4 mA, VIx = VIxH
IOx = 20 µA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
0 V ≤ VIx ≤ VDDx
IDDI(Q)
IDDO(Q)
IDDI(D)
IDDO(D)
0.4
1.2
0.08
0.015
VDDxUV+
VDDxUV−
VDDxUVH
2.6
2.4
0.2
V
V
V
3
35
ns
kV/µs
1.6
µs
tR/tF
|CM|
tr
25
0.6
1.7
Unit
mA
mA
mA/Mbps
mA/Mbps
10% to 90%
VIx = VDDx, VCM = 1000 V,
transient magnitude = 800 V
|CM| is the maximum common-mode voltage slew rate that can be sustained while maintaining Vo > 0.8 VDDX. The common-mode voltage slew rates apply to both
rising and falling common-mode voltage edges.
Rev. A | Page 4 of 20
Data Sheet
ADuM1280/ADuM1281/ADuM1285/ADuM1286
ELECTRICAL CHARACTERISTICS—MIXED 5 V/3 V OPERATION (A, B, AND C GRADES)
All typical specifications are at TA = 25°C, VDD1 = 5 V, VDD2 = 3.0 V. Minimum/maximum specifications apply over the entire
recommended operation range: 4.5 V ≤ VDD1 ≤ 5.5 V, 2.7 V ≤ VDD2 ≤ 3.6 V; and −40°C ≤ TA ≤ 125°C, unless otherwise noted. Switching
specifications are tested with C L = 15 pF and CMOS signal levels unless otherwise noted.
Table 7.
Parameter
Symbol
Min
SWITCHING SPECIFICATIONS
Pulse Width
Data Rate
PW
1000
A Grade
Typ
Min
Min
B Grade
Typ
Max
Min
40
C Grade
Typ
Max
10
1
25
50
10
35
3
Test Conditions
ns
Mbps
ns
ns
Within PWD limit
Within PWD limit
Propagation Delay
Pulse Width Distortion
tPHL, tPLH
PWD
Change vs. Temperature
Propagation Delay Skew
tPSK
38
16
12
ns
tPSKCD
tPSKOD
5
10
3
6
2
5
ns
ns
ns
7
13
100
26
Unit
20
2
3
50% input to 50% output
|tPLH − tPHL|
ps/C
1.5
Between any two units at
same operating conditions
Channel Matching
Codirectional
Opposing-Direction
Jitter
2
2
1
7Codir ect ionalchannelm at chingis t heabs olut evalueof t hedif f er enceinpr opagat iondelays bet weenanyt wochannels wit hinput s ont hes am es ideof t heis olat ionbar r ier .Oppos ing- dir ect ionalchannelm at chingis t heabs olut evalueof t hedif f er enceinpr opagat iondelays bet weenanyt wochannels wit hinput s onoppos ings ides of t heis olat ionbar r ier .
Table 8.
Parameter
Symbol
SUPPLY CURRENT
ADuM1280/ADuM1285
IDD1
ADuM1281/ADuM1286
1 Mbps–A, B, C Grade
Min
Typ
Min
25 Mbps–B, C Grade
Min
Typ
Max
100 Mbps–C Grade
Min
Typ
Max
Unit
Test Conditions
No load
1.6
1.1
2.0
2.1
1.7
IDD2
IDD1
IDD2
6.2
2.7
4.9
3.9
3.5
2.6
2.3
7.0
4.6
6.0
6.2
20
4.8
15
11
25
mA
9.0
19
15
mA
mA
mA
Table 9. For All Models
Parameter
DC SPECIFICATIONS
Logic High Input Threshold
Logic Low Input Threshold
Logic High Output Voltages
Min
VIH
VIL
VOH
0.7 VDDx
Logic Low Output Voltages
VOL
Input Current per Channel
Supply Current per Channel
Quiescent Input Supply Current
II
Quiescent Output Supply Current
Dynamic Input Supply Current
Dynamic Output Supply Current
Undervoltage Lockout
Positive VDDX Threshold
Negative VDDX Threshold
VDDX Hysteresis
AC SPECIFICATIONS
Output Rise/Fall Time
1
Symbol
VDDx − 0.1
VDDx − 0.4
−10
VDDxUV+
VDDxUV−
VDDxUVH
tR/tF
Refresh Period
tr
VDDx
VDDx − 0.2
0.0
0.2
+0.01
0.54
1.2
0.09
0.02
IDDO(Q)
IDDI(D)
IDDO(D)
|CM|
Max
Unit
Test Conditions
0.1
0.4
+10
V
V
V
V
V
V
µA
IOx = −20 µA, VIx = VIxH
IOx = −4 mA, VIx = VIxH
IOx = 20 µA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
0 V ≤ VIx ≤ VDDx
0.75
mA
2.0
mA
mA/Mbps
mA/Mbps
0.3 VDDx
IDDI(Q)
Common-Mode Transient Immunity1
Typ
25
2.6
2.4
0.2
V
V
2.5
35
ns
10% to 90%
kV/µs
VIx = VDDx, VCM = 1000 V,
transient magnitude = 800 V
1.6
µs
V
|CM| is the maximum common-mode voltage slew rate that can be sustained while maintaining Vo > 0.8 VDDX . The common-mode voltage slew rates apply to both
rising and falling common-mode voltage edges.
Rev. A | Page 5 of 20
ADuM1280/ADuM1281/ADuM1285/ADuM1286
Data Sheet
ELECTRICAL CHARACTERISTICS—MIXED 3 V/5 V OPERATION (A, B, AND C GRADES)
All typical specifications are at TA = 25°C, VDD1 = 3.0 V, VDD2 = 5 V. Minimum/maximum specifications apply over the entire
recommended operation range: 2.7 V ≤ VDD1 ≤ 3.6 V, 4.5 V ≤ VDD2 ≤ 5.5 V; and −40°C ≤ TA ≤ 125°C; unless otherwise noted. Switching
specifications are tested with CL=15 pF and CMOS signal levels, unless otherwise noted.
Table 10.
Parameter
SWITCHING SPECIFICATIONS
Pulse Width
Data Rate
Propagation Delay
Pulse Width Distortion
Change vs. Temperature
Propagation Delay Skew
Channel Matching
Codirectional
Opposing-Direction
Jitter
Symbol
Min
PW
1000
A Grade
Typ
Min
Min
B Grade
Typ
Max
Min
40
7
Unit
Test Conditions
2.5
ns
Mbps
ns
ns
Within PWD limit
Within PWD limit
50% input to 50% output
|tPLH − tPHL|
10
1
50
10
tPHL, tPLH
PWD
C Grade
Typ
Max
25
35
3
16
3
24
100
30
ps/C
1.5
tPSK
38
16
12
ns
tPSKCD
tPSKOD
5
10
3
6
2.5
5
ns
ns
ns
2
2
1
Between any two units at
same operating conditions
7 Codirectional channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on the same side of the isolation barrier. Opposing-directional channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on opposing sides of the isolation barrier.
Table 11.
Parameter
SUPPLY CURRENT
ADuM1280/ADuM1285
ADuM1281/ADuM1286
Symbol
1 Mbps–A, B, C Grade
Min
Typ
Min
IDD1
IDD2
IDD1
IDD2
0.75
2.7
1.6
1.7
25 Mbps–B, C Grade
Min
Typ
Max
1.4
4.5
2.1
2.3
5.1
4.8
3.8
3.9
9.0
7.0
5.0
6.2
100 Mbps–C Grade
Min
Typ
Max
17
9.5
11
11
23
15
15
15
Unit
Test Conditions
No load
mA
mA
mA
mA
Table 12. For All Models
Parameter
DC SPECIFICATIONS
Logic High Input Threshold
Logic Low Input Threshold
Logic High Output Voltages
Symbol
Min
VIH
VIL
VOH
0.7 VDDx
Logic Low Output Voltages
VOL
Input Current per Channel
Supply Current per Channel
Quiescent Input Supply Current
Quiescent Output Supply Current
Dynamic Input Supply Current
Dynamic Output Supply Current
II
Undervoltage-Lockout
Positive VDDX Threshold
Negative VDDX Threshold
VDDX Hysteresis
AC SPECIFICATIONS
Output Rise/Fall Time
Common-Mode Transient Immunity1
Refresh Period
1
Typ
Max
0.3 VDDx
VDDx − 0.1
VDDx − 0.4
−10
VDDx
VDDx − 0.2
0.0
0.2
+0.01
0.1
0.4
+10
Test Conditions
V
V
V
V
V
V
μA
IOx = −20 μA, VIx = VIxH
IOx = −4 mA, VIx = VIxH
IOx = 20 μA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
0 V ≤ VIx ≤ VDDx
IDDI(Q)
IDDO(Q)
IDDI(D)
IDDO(D)
0.4
1.6
0.08
0.03
mA
mA
mA/Mbps
mA/Mbps
VDDxUV+
VDDxUV−
VDDxUVH
2.6
2.4
0.2
V
V
V
2.5
35
ns
kV/μs
1.6
μs
tR/tF
|CM|
tr
25
0.75
2.0
Unit
10% to 90%
VIx = VDDx, VCM = 1000 V,
transient magnitude = 800 V
|CM| is the maximum common-mode voltage slew rate that can be sustained while maintaining Vo > 0.8 VDDX. The common-mode voltage slew rates apply to both
rising and falling common-mode voltage edges.
Rev. A | Page 6 of 20
Data Sheet
ADuM1280/ADuM1281/ADuM1285/ADuM1286
ELECTRICAL CHARACTERISTICS—3 V OPERATION (WA, WB, AND WC GRADES)
All typical specifications are at TA = 25°C, VDD1 = VDD2 = 3.0 V. Minimum/maximum specifications apply over the entire recommended
operation range: 3.0 V ≤ VDD1 ≤ 3.6 V, 3.0 V ≤ VDD2 ≤ 3.6 V, −40°C ≤ TA ≤ 125°C, unless otherwise noted. Switching specifications are
tested with CL = 15 pF and CMOS signal levels, unless otherwise noted.
Table 13.
Parameter
Symbol
Min
SWITCHING SPECIFICATIONS
Pulse Width
Data Rate
PW
1000
WA Grade
Typ
Min
Min
WB Grade
Typ
Max
Min
40
WC Grade
Typ
Max
10
1
25
50
10
35
3
Test Conditions
ns
Mbps
ns
ns
Within PWD limit
Within PWD limit
Propagation Delay
Pulse Width Distortion
tPHL, tPLH
PWD
Change vs. Temperature
Propagation Delay Skew
tPSK
38
16
12
ns
tPSKCD
tPSKOD
5
10
3
6
2.5
5
ns
ns
ns
7
20
100
33
Unit
25
2.5
3
50% input to 50% output
|tPLH − tPHL|
ps/°C
1.5
Between any two units at
same operating conditions
Channel Matching
Codirectional
Opposing-Direction
Jitter
2
2
1
7Codir ect ionalchannelm at chingis t heabs olut evalueof t hedif f er enceinpr opagat iondelays bet weenanyt wochannels wit hinput s ont hes am es ideof t heis olat ionbar r ier .Oppos ing- dir ect ionalchannelm at chingis t heabs olut evalueof t hedif f er enceinpr opagat iondelays bet weenanyt wochannels wit hinput s onoppos ings ides of t heis olat ionbar r ier .
Table 14.
Parameter
SUPPLY CURRENT
ADuM1280/ADuM1285
ADuM1281/ADuM1286
Symbol
1 Mbps–WA, WB, WC
Grades
Min
Typ
Min
25 Mbps–WB, WC
Grades
Min
Typ
Max
100 Mbps–WC Grade
Min
Typ
Max
Unit
Test Conditions
No load
IDD1
IDD2
0.75
2.0
1.6
1.7
IDD1
IDD2
1.4
3.5
5.1
2.7
3.8
3.9
2.1
2.3
9.0
4.6
5.0
6.2
17
4.8
11
11
23
9
15
15
mA
mA
mA
mA
Table 15. For All Models
Parameter
Symbol
Min
DC SPECIFICATIONS
Logic High Input Threshold
Logic Low Input Threshold
Logic High Output Voltages
VIH
VIL
VOH
0.7 VDDx
Logic Low Output Voltages
VOL
Input Current per Channel
Supply Current per Channel
Quiescent Input Supply Current
Quiescent Output Supply Current
Dynamic Input Supply Current
Dynamic Output Supply Current
Undervoltage Lockout
Positive VDDx Threshold
Negative VDDx Threshold
VDDX Hysteresis
II
AC SPECIFICATIONS
Output Rise/Fall Time
Common-Mode Transient Immunity1
Refresh Period
1
Typ
Max
0.3 VDDx
VDDx − 0.1
VDDx − 0.4
−10
3.0
2.8
0.0
0.2
+0.01
0.1
0.4
+10
Test Conditions
V
V
V
V
V
V
µA
IOx = −20 µA, VIx = VIxH
IOx = −4 mA, VIx = VIxH
IOx = 20 µA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
0 V ≤ VIx ≤ VDDx
IDDI(Q)
IDDO(Q)
IDDI(D)
IDDO(D)
0.4
1.2
0.08
0.015
VDDxUV+
VDDxUV−
VDDxUVH
2.6
2.4
0.2
V
V
V
3
35
ns
kV/µs
1.6
µs
tR/tF
|CM|
tr
25
0.6
1.7
Unit
mA
mA
mA/Mbps
mA/Mbps
10% to 90%
VIx = VDDx, VCM = 1000 V,
transient magnitude = 800 V
|CM| is the maximum common-mode voltage slew rate that can be sustained while maintaining Vo > 0.8 VDDX. The common-mode voltage slew rates apply to both
rising and falling common-mode voltage edges.
Rev. A | Page 7 of 20
ADuM1280/ADuM1281/ADuM1285/ADuM1286
Data Sheet
ELECTRICAL CHARACTERISTICS—MIXED 5 V/3 V OPERATION (WA, WB, AND WC GRADES)
All typical specifications are at TA = 25°C, VDD1 = 5 V, VDD2 = 3.0 V. Minimum/maximum specifications apply over the entire recommended
operation range: 4.5 V ≤ VDD1 ≤ 5.5 V, 3.0 V ≤ VDD2 ≤ 3.6 V; and −40°C ≤ TA ≤ 125°C, unless otherwise noted. Switching specifications are
tested with CL = 15 pF and CMOS signal levels unless otherwise noted.
Table 16.
Parameter
SWITCHING SPECIFICATIONS
Pulse Width
Data Rate
Propagation Delay
Pulse Width Distortion
Change vs. Temperature
Propagation Delay Skew
Channel Matching
Codirectional
Opposing-Direction
Jitter
Symbol
Min
PW
1000
WA Grade
Typ
Min
Min
WB Grade
Typ
Max
Min
40
7
Unit
Test Conditions
2
ns
Mbps
ns
ns
Within PWD limit
Within PWD limit
50% input to 50% output
|tPLH − tPHL|
10
1
50
10
tPHL, tPLH
PWD
WC Grade
Typ
Max
25
35
3
13
3
20
100
26
ps/C
1.5
tPSK
38
16
12
ns
tPSKCD
tPSKOD
5
10
3
6
2
5
ns
ns
ns
2
2
1
Between any two units at
same operating conditions
7 Codirectional channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on the same side of the isolation barrier. Opposing-directional channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on opposing sides of the isolation barrier.
Table 17.
Parameter
SUPPLY CURRENT
ADuM1280/ADuM1285
ADuM1281/ADuM1286
Symbol
1 Mbps–WA, WB, WC
Grades
Min
Typ
Min
IDD1
IDD2
IDD1
IDD2
25 Mbps–WB, WC
Grades
Min
Typ
Max
1.6
3.5
2.6
2.3
1.1
2.0
2.1
1.7
6.2
2.7
4.9
3.9
7.0
4.6
6.0
6.2
100 Mbps–WC Grade
Min
Typ
Max
20
4.8
15
11
25
9.0
19
15
Unit
Test Conditions
No load
mA
mA
mA
mA
Table 18. For All Models
Parameter
DC SPECIFICATIONS
Logic High Input Threshold
Logic Low Input Threshold
Logic High Output Voltages
Symbol
Min
VIH
VIL
VOH
0.7 VDDx
Logic Low Output Voltages
VOL
Input Current per Channel
Supply Current per Channel
Quiescent Input Supply Current
Quiescent Output Supply Current
Dynamic Input Supply Current
Dynamic Output Supply Current
Undervoltage Lockout
Positive VDDX Threshold
Negative VDDX Threshold
VDDX Hysteresis
II
AC SPECIFICATIONS
Output Rise/Fall Time
Common-Mode Transient Immunity1
Refresh Period
Typ
Max
0.3 VDDx
VDDx − 0.1
VDDx − 0.4
−10
VDDx
VDDx − 0.2
0.0
0.2
+0.01
0.1
0.4
+10
Test Conditions
V
V
V
V
V
V
μA
IOx = −20 μA, VIx = VIxH
IOx = −4 mA, VIx = VIxH
IOx = 20 μA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
0 V ≤ VIx ≤ VDDx
IDDI(Q)
IDDO(Q)
IDDI(D)
IDDO(D)
0.54
1.2
0.09
0.02
VDDxUV+
VDDxUV−
VDDxUVH
2.6
2.4
0.2
V
V
V
2.5
35
ns
kV/μs
1.6
μs
tR/tF
|CM|
tr
25
1
0.75
2.0
Unit
mA
mA
mA/Mbps
mA/Mbps
10% to 90%
VIx = VDDx, VCM = 1000 V,
transient magnitude = 800 V
|CM| is the maximum common-mode voltage slew rate that can be sustained while maintaining Vo > 0.8 VDDX. The common-mode voltage slew rates apply to both
rising and falling common-mode voltage edges.
Rev. A | Page 8 of 20
Data Sheet
ADuM1280/ADuM1281/ADuM1285/ADuM1286
ELECTRICAL CHARACTERISTICS—MIXED 3 V/5 V OPERATION (WA, WB, AND WC GRADES)
All typical specifications are at TA = 25°C, VDD1 = 3.0 V, VDD2 = 5 V. Minimum/maximum specifications apply over the entire recommended
operation range: 3.0 V ≤ VDD1 ≤ 3.6 V, 4.5 V ≤ VDD2 ≤ 5.5 V; and −40°C ≤ TA ≤ 125°C; unless otherwise noted. Switching specifications are
tested with CL=15 pF and CMOS signal levels, unless otherwise noted.
Table 19.
Parameter
SWITCHING SPECIFICATIONS
Pulse Width
Data Rate
Propagation Delay
Pulse Width Distortion
Change vs. Temperature
Propagation Delay Skew
Channel Matching
Codirectional
Opposing-Direction
Jitter
Symbol
Min
PW
1000
WA Grade
Typ
Min
Min
WB Grade
Typ
Max
Min
40
7
Unit
Test Conditions
2.5
ns
Mbps
ns
ns
Within PWD limit
Within PWD limit
50% input to 50% output
|tPLH − tPHL|
10
1
50
10
tPHL, tPLH
PWD
WC Grade
Typ
Max
25
35
3
16
3
24
100
30
ps/C
1.5
tPSK
38
16
12
ns
tPSKCD
tPSKOD
5
10
3
6
2.5
5
ns
ns
ns
2
2
1
Between any two units at
same operating conditions
7 Codirectional channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on the same side of the isolation barrier. Opposing-directional channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on opposing sides of the isolation barrier.
Table 20.
Parameter
SUPPLY CURRENT
ADuM1280/ADuM1285
ADuM1281/ADuM1286
Symbol
1 Mbps–WA, WB, WC
Grades
Min
Typ
Min
IDD1
IDD2
IDD1
IDD2
0.75
2.7
1.6
1.7
25 Mbps–WB, WC
Grades
Min
Typ
Max
1.4
4.5
2.1
2.3
5.1
4.8
3.8
3.9
9.0
7.0
5.0
6.2
100 Mbps–WC Grade
Min
Typ
Max
17
9.5
11
11
23
15
15
15
Unit
Test Conditions
No load
mA
mA
mA
mA
Table 21. For All Models
Parameter
DC SPECIFICATIONS
Logic High Input Threshold
Logic Low Input Threshold
Logic High Output Voltages
Symbol
Min
VIH
VIL
VOH
0.7 VDDx
Logic Low Output Voltages
VOL
Input Current per Channel
Supply Current per Channel
Quiescent Input Supply Current
Quiescent Output Supply Current
Dynamic Input Supply Current
Dynamic Output Supply Current
II
Undervoltage-Lockout
Positive VDDX Threshold
Negative VDDX Threshold
VDDX Hysteresis
AC SPECIFICATIONS
Output Rise/Fall Time
Common-Mode Transient Immunity1
Refresh Period
Typ
Max
0.3 VDDx
VDDx − 0.1
VDDx − 0.4
−10
VDDx
VDDx − 0.2
0.0
0.2
+0.01
0.1
0.4
+10
Test Conditions
V
V
V
V
V
V
μA
IOx = −20 μA, VIx = VIxH
IOx = −4 mA, VIx = VIxH
IOx = 20 μA, VIx = VIxL
IOx = 4 mA, VIx = VIxL
0 V ≤ VIx ≤ VDDx
IDDI(Q)
IDDO(Q)
IDDI(D)
IDDO(D)
0.4
1.6
0.08
0.03
mA
mA
mA/Mbps
mA/Mbps
VDDxUV+
VDDxUV−
VDDxUVH
2.6
2.4
0.2
V
V
V
2.5
35
ns
kV/μs
1.6
μs
tR/tF
|CM|
tr
25
1
0.75
2.0
Unit
10% to 90%
VIx = VDDx, VCM = 1000 V,
transient magnitude = 800 V
|CM| is the maximum common-mode voltage slew rate that can be sustained while maintaining Vo > 0.8 VDDX. The common-mode voltage slew rates apply to both
rising and falling common-mode voltage edges.
Rev. A | Page 9 of 20
ADuM1280/ADuM1281/ADuM1285/ADuM1286
Data Sheet
PACKAGE CHARACTERISTICS
Table 22.
Parameter
Resistance (Input-to-Output) 1
Capacitance (Input-to-Output)1
Input Capacitance 2
IC Junction-to-Ambient Thermal
Resistance
1
2
Symbol
RI-O
CI-O
CI
θJA
Min
Typ
1013
2
4.0
85
Max
Unit
Ω
pF
pF
°C/W
Test Conditions
f = 1 MHz
Thermocouple located at center of package underside
The device is considered a 2-terminal device; Pin 1 through Pin 4 are shorted together and Pin 5 through Pin 8 are shorted together.
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM128x is pending approval by the organizations listed in Table 23. See Table 27 and Table 28 for recommended maximum
working voltages for specific cross-isolation waveforms and insulation levels.
Table 23.
UL (Pending)
Recognized under UL 1577
Component Recognition Program 1
Single Protection, 3000 V RMS
Isolation Voltage
File E214100
1
2
CSA (Pending)
Approved under CSA Component Acceptance
Notice #5A
Basic insulation per CSA 60950-1-03 and
IEC 60950-1, 400 V rms (565 V peak) maximum
working voltage
File 205078
VDE (Pending)
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10): 2006-12 2
Reinforced insulation, 560 V peak
File 2471900-4880-0001
In accordance with UL 1577, each ADuM128x is proof tested by applying an insulation test voltage ≥ 3600 V rms for 1 second (current leakage detection limit = 6 µA).
In accordance with DIN V VDE V 0884-10, each ADuM128x is proof tested by applying an insulation test voltage ≥1050 V peak for 1 second (partial discharge detection
limit = 5 pC). The asterisk (*) marked on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 24.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Symbol
L(I01)
Value
3000
4.0
Unit
V rms
mm min
Minimum External Tracking (Creepage)
L(I02)
4.0
mm min
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
CTI
0.017
>400
II
mm min
V
Rev. A | Page 10 of 20
Conditions
1-minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Data Sheet
ADuM1280/ADuM1281/ADuM1285/ADuM1286
DIN V VDE V 0884-10 (VDE V 0884-10): 2006-12 INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation within the safety limit data only. Maintenance of the safety data is ensured by
protective circuits. The asterisk (*) marked on packages denotes DIN V VDE V 0884-10 approval.
Table 25.
Description
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method B1
Conditions
VIORM × 1.875 = Vpd(m), 100% production test,
tini = tm = 1 sec, partial discharge < 5 pC
Input-to-Output Test Voltage, Method A
After Environmental Tests Subgroup 1
VIORM × 1.5 = Vpd(m), tini=60 sec, tm = 10 sec,
partial discharge < 5 pC
VIORM × 1.2 = Vpd(m), tini = 60 sec, tm = 10 sec,
partial discharge < 5 pC
After Input and/or Safety Test Subgroup 2
and Subgroup 3
Highest Allowable Overvoltage
Withstand Isolation Voltage
Surge Isolation Voltage
Safety Limiting Values
1 minute withstand rating
VPEAK = 10 kV, 1.2 µs rise time, 50 µs, 50% fall time
Maximum value allowed in the event of a failure
(see Figure 3)
Case Temperature
Side 1 IDD1 Current
Insulation Resistance at TS
VIO = 500 V
Characteristic
Unit
VIORM
Vpd(m)
I to IV
I to III
I to II
40/105/21
2
560
1050
VPEAK
VPEAK
Vpd(m)
840
VPEAK
Vpd(m)
672
VPEAK
VIOTM
VISO
VIOSM
4000
3000
6000
VPEAK
VRMS
VPEAK
TS
IS1
RS
150
290
>109
°C
mA
Ω
RECOMMENDED OPERATING CONDITIONS
300
Table 26.
250
Parameter
Operating Temperature
Supply Voltages 1
A, B, and C Grades
WA, WB, and WC Grades
Input Signal Rise and Fall Times
200
150
100
1
0
0
50
100
150
AMBIENT TEMPERATURE (°C)
200
Symbol
TA
VDD1, VDD2
Min
−40
Max
+125
Unit
°C
2.7
3.0
5.5
5.5
1.0
V
V
ms
See the DC Correctness and Magnetic Field Immunity section.
50
10444-003
SAFETY-LIMITING CURRENT (mA)
Symbol
Figure 3. Thermal Derating Curve at VDDx = 5 V, Dependence of SafetyLimiting Values with Case Temperature per DIN V VDE V 0884-10
Rev. A | Page 11 of 20
ADuM1280/ADuM1281/ADuM1285/ADuM1286
Data Sheet
ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 27.
Parameter
Storage Temperature (TST) Range
Ambient Operating Temperature
(TA) Range
Supply Voltages (VDD1, VDD2)
Input Voltages (VIA, VIB)
Output Voltages (VOA, VOB)
Average Output Current per Pin1
Side 1 (IO1)
Side 2 (IO2)
Common-Mode Transients2
1
2
Rating
−65°C to +150°C
−40°C to +125°C
−0.5 V to +7.0 V
−0.5 V to VDDI + 0.5 V
−0.5 V to VDD2 + 0.5 V
ESD CAUTION
−10 mA to +10 mA
−10 mA to +10 mA
−100 kV/μs to +100 kV/μs
See Figure 3 for maximum rated current values for various temperatures.
Refers to common-mode transients across the insulation barrier. Commonmode transients exceeding the absolute maximum ratings may cause
latch-up or permanent damage.
Table 28. Maximum Continuous Working Voltage1
Parameter
AC Voltage, Bipolar Waveform
AC Voltage, Unipolar Waveform
Basic Insulation
Reinforced Insulation
DC Voltage
Basic Insulation
Reinforced Insulation
1
Max
565
Unit
V peak
Constraint
50-year minimum lifetime
1131
560
V peak
V peak
Maximum approved working voltage per IEC 60950-1
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
1131
560
V peak
V peak
Maximum approved working voltage per IEC 60950-1
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
Refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more details.
Rev. A | Page 12 of 20
Data Sheet
ADuM1280/ADuM1281/ADuM1285/ADuM1286
VDD1 1
VIA 2
VIB 3
GND1 4
ADuM1280/
ADuM1285
8 VDD2
7 VOA
TOP VIEW
(Not to Scale)
6 VOB
5 GND2
10444-004
PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS
Figure 4. ADuM1280/ADuM1285 Pin Configuration
Table 29. ADuM1280/ADuM1285 Pin Function Descriptions
Mnemonic
VDD1
2
3
4
5
6
7
8
VIA
VIB
GND1
GND2
VOB
VOA
VDD2
Description
Supply Voltage for Isolator Side 1 (2.7 V to 5.5 V for A, B, and C grades, 3.0 V to 5.5 V for WA,
WB, and WC grades).
Logic Input A.
Logic Input B.
Ground 1. Ground reference for Isolator Side 1.
Ground 2. Ground reference for Isolator Side 2.
Logic Output B.
Logic Output A.
Supply Voltage for Isolator Side 2 (2.7 V to 5.5 V for A, B, and C grades, 3.0 V to 5.5 V for WA,
WB, and WC grades).
VDD1 1
VOA 2
VIB 3
GND1 4
ADuM1281/
ADuM1286
TOP VIEW
(Not to Scale)
8 VDD2
7 VIA
6 VOB
5 GND2
10444-005
Pin No.
1
Figure 5. ADuM1281/ADuM1286 Pin Configuration
Table 30. ADuM1281/ADuM1286 Pin Function Descriptions
Pin No.
1
Mnemonic
VDD1
2
3
4
5
6
7
8
VOA
VIB
GND1
GND2
VOB
VIA
VDD2
Description
Supply Voltage for Isolator Side 1 (2.7 V to 5.5 V for A, B, and C grades, 3.0 V to 5.5 V for WA,
WB, and WC grades).
Logic Output A.
Logic Input B.
Ground 1. Ground reference for Isolator Side 1.
Ground 2. Ground reference for Isolator Side 2.
Logic Output B.
Logic Input A.
Supply Voltage for Isolator Side 2 (2.7 V to 5.5 V for A, B, and C grades, 3.0 V to 5.5 V for WA,
WB, and WC grades).
For specific layout guidelines, refer to the AN-1109 Application Note, Recommendations for Control of Radiated Emissions with iCoupler
Devices.
Rev. A | Page 13 of 20
ADuM1280/ADuM1281/ADuM1285/ADuM1286
Data Sheet
Table 31. ADuM1280 Truth Table (Positive Logic)
V IA Input
H
L
H
L
L
V IB Input
H
L
L
H
L
V DD1 State
Powered
Powered
Powered
Powered
Unpowered
V DD2 State
Powered
Powered
Powered
Powered
Powered
V OA Output
H
L
H
L
H
VOB Output
H
L
L
H
H
X
X
Powered
Unpowered
Indeterminate
Indeterminate
Notes
Outputs return to the input state within
1.6 µs of VDDI power restoration.
Outputs return to the input state within
1.6 µs of VDDO power restoration.
Table 32. ADuM1281 Truth Table (Positive Logic)
V IA Input
H
L
H
L
X
V IB Input
H
L
L
H
L
V DD1 State
Powered
Powered
Powered
Powered
Unpowered
V DD2 State
Powered
Powered
Powered
Powered
Powered
V OA Output
H
L
H
L
Indeterminate
V OB Output
H
L
L
H
H
L
X
Powered
Unpowered
H
Indeterminate
Notes
Outputs return to the input state within
1.6 µs of VDD1 power restoration.
Outputs return to the input state within
1.6 µs of VDDO power restoration.
Table 33. ADuM1285 Truth Table (Positive Logic)
V IA Input
H
L
H
L
L
V IB Input
H
L
L
H
L
V DD1 State
Powered
Powered
Powered
Powered
Unpowered
V DD2 State
Powered
Powered
Powered
Powered
Powered
V OA Output
H
L
H
L
L
VOB Output
H
L
L
H
L
X
X
Powered
Unpowered
Indeterminate
Indeterminate
Notes
Outputs return to the input state within
1.6 µs of VDDI power restoration.
Outputs return to the input state within
1.6 µs of VDDO power restoration.
Table 34. ADuM1286 Truth Table (Positive Logic)
V IA Input
H
L
H
L
X
V IB Input
H
L
L
H
L
V DD1 State
Powered
Powered
Powered
Powered
Unpowered
V DD2 State
Powered
Powered
Powered
Powered
Powered
V OA Output
H
L
H
L
Indeterminate
V OB Output
H
L
L
H
L
L
X
Powered
Unpowered
L
Indeterminate
Rev. A | Page 14 of 20
Notes
Outputs return to the input state within
1.6 µs of VDD1 power restoration.
Outputs return to the input state within
1.6 µs of VDDO power restoration.
Data Sheet
ADuM1280/ADuM1281/ADuM1285/ADuM1286
TYPICAL PERFORMANCE CHARACTERISTICS
10
20
8
CURRENT (mA)
CURRENT (mA)
15
6
5V
3V
4
5V
10
3V
5
0
10
20
30
40
50
60
70
80
90
100
DATA RATE (Mbps)
0
10444-006
0
0
10
20
30
40
50
60
70
80
90
100
DATA RATE (Mbps)
Figure 6. Typical Supply Current per Input Channel vs. Data Rate
for 5 V and 3 V Operation
10444-009
2
Figure 9. Typical ADuM1280 or ADuM1285 VDD1 Supply Current vs.
Data Rate for 5 V and 3 V Operation
10
20
8
CURRENT (mA)
CURRENT (mA)
15
6
4
5V
10
5V
5
2
0
10
20
30
40
50
60
70
80
90
100
DATA RATE (Mbps)
0
10444-007
0
Figure 7. Typical Supply Current per Output Channel vs. Data Rate
for 5 V and 3 V Operation (No Output Load)
0
10
20
30
40
50
60
70
80
90
100
DATA RATE (Mbps)
10444-010
3V
3V
Figure 10. Typical ADuM1280 or ADuM1285 VDD2 Supply Current vs.
Data Rate for 5 V and 3 V Operation
10
20
8
CURRENT (mA)
6
5V
4
10
5V
3V
5
2
0
0
10
20
30
40
50
60
70
80
90
100
DATA RATE (Mbps)
Figure 8. Typical Supply Current per Output Channel vs. Data Rate
for 5 V and 3 V Operation (15 pF Output Load)
0
0
10
20
30
40
50
60
DATA RATE (Mbps)
70
80
90
100
10444-011
3V
10444-008
CURRENT (mA)
15
Figure 11. Typical ADuM1281 or ADuM1286 VDD1 or VDD2 Supply Current vs.
Data Rate for 5 V and 3 V Operation
Rev. A | Page 15 of 20
ADuM1280/ADuM1281/ADuM1285/ADuM1286
Data Sheet
APPLICATIONS INFORMATION
PC BOARD LAYOUT
The ADuM128x digital isolator requires no external interface
circuitry for the logic interfaces. Power supply bypassing is
strongly recommended at both input and output supply pins
VDD1 and VDD2 (see Figure 12). The capacitor value should be
between 0.01 μF and 0.1 μF. The total lead length between both
ends of the capacitor and the input power supply pin should not
exceed 20 mm.
The ADuM128x can readily meet CISPR 22 Class A (and
FCC Class A) emissions standards, as well as the more
stringent CISPR 22 Class B (and FCC Class B) standards in
an unshielded environment, with proper PCB design choices.
Refer to the AN-1109 Applicaton Note, Recommendations for
Control of Radiated Emissions with iCoupler Devices for PCBrelated EMI mitigation techniques, including board layout and
stack-up issues.
PROPAGATION DELAY-RELATED PARAMETERS
Propagation delay is a parameter that describes the time it takes
a logic signal to propagate through a component. The input-tooutput propagation delay time for a high-to-low transition may
differ from the propagation delay time of a low-to-high
transition.
50%
If the decoder receives no pulses for more than about 6.4 μs, the
input side is assumed to be unpowered or nonfunctional, in which
case, the isolator output is forced to a default low state by the
watchdog timer circuit.
The limitation on the device’s magnetic field immunity is set
by the condition in which induced voltage in the transformer
receiving coil is sufficiently large to either falsely set or reset the
decoder. The following analysis defines such conditions. The
ADuM1280 is examined in a 3 V operating condition because it
represents the most susceptible mode of operation of this product.
The pulses at the transformer output have an amplitude greater
than 1.5 V. The decoder has a sensing threshold of about 1.0 V,
therefore establishing a 0.5 V margin in which induced voltages
can be tolerated. The voltage induced across the receiving coil is
given by
V = (−dβ/dt)∑rn2; n = 1, 2, …, N
tPHL
OUTPUT (VOx)
10444-012
tPLH
Positive and negative logic transitions at the isolator input
cause narrow (~1 ns) pulses to be sent via the transformer to
the decoder. The decoder is bistable and is, therefore, either set
or reset by the pulses indicating input logic transitions. In the
absence of logic transitions at the input for more than ~1.6 μs,
a periodic set of refresh pulses indicative of the correct input
state are sent to ensure dc correctness at the output.
50%
Figure 12. Propagation Delay Parameters
Pulse width distortion is the maximum difference between
these two propagation delay values and an indication of how
accurately the timing of the input signal is preserved.
Propagation delay skew refers to the maximum amount the
propagation delay differs between multiple ADuM128x
components operating under the same conditions.
Given the geometry of the receiving coil in the ADuM1280 and
an imposed requirement that the induced voltage be, at most,
50% of the 0.5 V margin at the decoder, a maximum allowable
magnetic field is calculated, as shown in Figure 13.
100
MAXIMUM ALLOWABLE MAGNETIC FLUX
DENSITY (kgauss)
Channel-to-channel matching refers to the maximum amount
the propagation delay differs between channels within a single
ADuM128x component.
where:
β is the magnetic flux density.
rn is the radius of the nth turn in the receiving coil.
N is the number of turns in the receiving coil.
10
1
0.1
0.01
0.001
1k
10k
100k
1M
10M
MAGNETIC FIELD FREQUENCY (Hz)
100M
Figure 13. Maximum Allowable External Magnetic Flux Density
Rev. A | Page 16 of 20
10444-013
INPUT (VIx)
DC CORRECTNESS AND MAGNETIC FIELD
IMMUNITY
Data Sheet
ADuM1280/ADuM1281/ADuM1285/ADuM1286
For example, at a magnetic field frequency of 1 MHz, the
maximum allowable magnetic field of 0.08 kgauss induces
a voltage of 0.25 V at the receiving coil. This is about 50% of the
sensing threshold and does not cause a faulty output transition.
If such an event occurs, with the worst-case polarity, during a
transmitted pulse, it would reduce the received pulse from >1.0 V
to 0.75 V. This is still well above the 0.5 V sensing threshold of
the decoder.
The preceding magnetic flux density values correspond to specific
current magnitudes at given distances away from the ADuM1280
transformers. Figure 14 expresses these allowable current magnitudes as a function of frequency for selected distances. The
ADuM1280 is very insensitive to external fields. Only extremely
large, high frequency currents, very close to the component
could potentially be a concern. For the 1 MHz example noted,
one would have to place a 0.2 kA current 5 mm away from the
ADuM1280 to affect component operation.
Note that at combinations of strong magnetic field and high
frequency, any loops formed by printed circuit board traces
could induce sufficiently large error voltages to trigger the
thresholds of succeeding circuitry. Take care to avoid PCB
structures that form loops.
POWER CONSUMPTION
The supply current at a given channel of the ADuM128x
isolator is a function of the supply voltage, the data rate of
the channel, and the output load of the channel.
For each input channel, the supply current is given by
DISTANCE = 100mm
1
DISTANCE = 5mm
0.1
0.01
100k
1M
10M
MAGNETIC FIELD FREQUENCY (Hz)
Figure 14. Maximum Allowable Current for
Various Current to ADuM1280 Spacings
100M
10444-014
MAXIMUM ALLOWABLE CURRENT (kA)
10
10k
IDDI = IDDI ( D) × (2f − fr) + IDDI (Q)
f > 0.5 fr
IDDO = IDDO (Q)
f ≤ 0.5 fr
IDDO = (IDDO (D) + (0.5 × 10 ) × CL × VDDO) × (2f − fr) + IDDO (Q)
f > 0.5 fr
−3
where:
IDDI (D), IDDO (D) are the input and output dynamic supply currents
per channel (mA/Mbps).
CL is the output load capacitance (pF).
VDDO is the output supply voltage (V).
f is the input logic signal frequency (MHz); it is half the input
data rate, expressed in units of Mbps.
fr is the input stage refresh rate (Mbps) = 1/tr (µs).
IDDI (Q), IDDO (Q) are the specified input and output quiescent
supply currents (mA).
100
1k
f ≤ 0.5 fr
For each output channel, the supply current is given by
1000
DISTANCE = 1m
IDDI = IDDI (Q)
To calculate the total VDD1 and VDD2 supply current, the supply
currents for each input and output channel corresponding to
VDD1 and VDD2 are calculated and totaled. Figure 6 and Figure 7
show per-channel supply currents as a function of data rate for
an unloaded output condition. Figure 8 shows the per-channel
supply current as a function of data rate for a 15 pF output
condition. Figure 9 through Figure 11 show the total VDD1 and
VDD2 supply current as a function of data rate for ADuM1280/
ADuM1281 channel configurations.
Rev. A | Page 17 of 20
ADuM1280/ADuM1281/ADuM1285/ADuM1286
Note that the voltage presented in Figure 17 is shown as
sinusoidal for illustration purposes only. It is meant to represent
any voltage waveform varying between 0 V and some limiting
value. The limiting value can be positive or negative, but the
voltage cannot cross 0 V.
The insulation lifetime of the ADuM128x depends on the
voltage waveform type imposed across the isolation barrier.
The iCoupler insulation structure degrades at different rates
depending on whether the waveform is bipolar ac, unipolar
ac, or dc. Figure 15, Figure 16, and Figure 17 illustrate these
different isolation voltage waveforms.
Bipolar ac voltage is the most stringent environment. The goal
of a 50-year operating lifetime under the ac bipolar condition
determines the Analog Devices recommended maximum
working voltage.
RATED PEAK VOLTAGE
10444-015
Analog Devices performs accelerated life testing using voltage
levels higher than the rated continuous working voltage.
Acceleration factors for several operating conditions are
determined. These factors allow calculation of the time to
failure at the actual working voltage. The values shown in
Table 28 summarize the peak voltage for 50 years of service life
for a bipolar ac operating condition and the maximum
CSA/VDE approved working voltages. In many cases, the
approved working voltage is higher than the 50-year service
life voltage. Operation at these high working voltages can
lead to shortened insulation life in some cases.
0V
Figure 15. Bipolar AC Waveform
RATED PEAK VOLTAGE
10444-016
All insulation structures eventually break down when subjected
to voltage stress over a sufficiently long period. The rate of
insulation degradation is dependent on the characteristics of the
voltage waveform applied across the insulation. In addition to
the testing performed by the regulatory agencies, Analog
Devices carries out an extensive set of evaluations to determine
the lifetime of the insulation structure within the ADuM128x.
In the case of unipolar ac or dc voltage, the stress on the
insulation is significantly lower. This allows operation at higher
working voltages while still achieving a 50-year service life. The
working voltages listed in Table 28 can be applied while maintaining the 50-year minimum lifetime provided the voltage
conforms to either the unipolar ac or dc voltage case. Any crossinsulation voltage waveform that does not conform to Figure 16
or Figure 17 should be treated as a bipolar ac waveform, and its
peak voltage should be limited to the 50-year lifetime voltage
value listed in Table 28.
0V
Figure 16. Unipolar AC Waveform
RATED PEAK VOLTAGE
10444-017
INSULATION LIFETIME
Data Sheet
0V
Figure 17. DC Waveform
Rev. A | Page 18 of 20
Data Sheet
ADuM1280/ADuM1281/ADuM1285/ADuM1286
OUTLINE DIMENSIONS
5.00 (0.1968)
4.80 (0.1890)
1
5
4
1.27 (0.0500)
BSC
0.25 (0.0098)
0.10 (0.0040)
COPLANARITY
0.10
SEATING
PLANE
6.20 (0.2441)
5.80 (0.2284)
1.75 (0.0688)
1.35 (0.0532)
0.51 (0.0201)
0.31 (0.0122)
0.50 (0.0196)
0.25 (0.0099)
45°
8°
0°
0.25 (0.0098)
0.17 (0.0067)
1.27 (0.0500)
0.40 (0.0157)
COMPLIANT TO JEDEC STANDARDS MS-012-AA
CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS
(IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR
REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN.
012407-A
8
4.00 (0.1574)
3.80 (0.1497)
Figure 18. 8-Lead Standard Small Outline Package [SOIC_N]
Narrow Body (R-8)
Dimensions shown in millimeters (inches)
ORDERING GUIDE
Model1,2,3
ADuM1280ARZ
ADuM1280WARZ
ADuM1280BRZ
ADuM1280WBRZ
ADuM1280CRZ
ADuM1280WCRZ
ADuM1281ARZ
ADuM1281WARZ
ADuM1281BRZ
ADuM1281WBRZ
ADuM1281CRZ
ADuM1281WCRZ
ADuM1285ARZ
ADuM1285WARZ
ADuM1285BRZ
ADuM1285WBRZ
ADuM1285CRZ
ADuM1285WCRZ
ADuM1286ARZ
ADuM1286WARZ
ADuM1286BRZ
ADuM1286WBRZ
ADuM1286CRZ
ADuM1286WCRZ
No. of Inputs, No. of Inputs,
VDD2 Side
VDD1 Side
2
0
2
0
2
0
2
0
2
0
2
0
1
1
1
1
1
1
1
1
1
1
1
1
2
0
2
0
2
0
2
0
2
0
2
0
1
1
1
1
1
1
1
1
1
1
1
1
Max
Data Rate
1 Mbps
1 Mbps
25 Mbps
25 Mbps
100 Mbps
100 Mbps
1 Mbps
1 Mbps
25 Mbps
25 Mbps
100 Mbps
100 Mbps
1 Mbps
1 Mbps
25 Mbps
25 Mbps
100 Mbps
100 Mbps
1 Mbps
1 Mbps
25 Mbps
25 Mbps
100 Mbps
100 Mbps
Max Prop Output
Temperature
Delay, 5 V Default State Range
50
High
−40°C to +125°C
50
High
−40°C to +125°C
35
High
−40°C to +125°C
35
High
−40°C to +125°C
24
High
−40°C to +125°C
24
High
−40°C to +125°C
50
High
−40°C to +125°C
50
High
−40°C to +125°C
35
High
−40°C to +125°C
35
High
−40°C to +125°C
24
High
−40°C to +125°C
24
High
−40°C to +125°C
50
Low
−40°C to +125°C
50
Low
−40°C to +125°C
35
Low
−40°C to +125°C
35
Low
−40°C to +125°C
24
Low
−40°C to +125°C
24
Low
−40°C to +125°C
50
Low
−40°C to +125°C
50
Low
−40°C to +125°C
35
Low
−40°C to +125°C
35
Low
−40°C to +125°C
24
Low
−40°C to +125°C
24
Low
−40°C to +125°C
Package Description
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
8-Lead SOIC_N
Package
Option
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
R-8
1
Z = RoHS Compliant Part.
Tape and reel are available. The addition of an “-RL7” suffix designates a 7” (1,000 units) tape and reel option.
3
W = Qualified for Automotive Applications.
2
AUTOMOTIVE PRODUCTS
The ADuM1280W, ADuM1281W, ADuM1285W, and ADuM1286W models are available with controlled manufacturing to support the
quality and reliability requirements of automotive applications. Note that these automotive models may have specifications that differ
from the commercial models; therefore, designers should review the Specifications section of this data sheet carefully. Only the
automotive grade products shown are available for use in automotive applications. Contact your local Analog Devices account
representative for specific product ordering information and to obtain the specific Automotive Reliability reports for these models.
Rev. A | Page 19 of 20
ADuM1280/ADuM1281/ADuM1285/ADuM1286
NOTES
©2012–2013 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D10444-0-3/13(A)
Rev. A | Page 20 of 20
Data Sheet