GENERAL DESCRIPTION
Monitors up to 5 voltages
Controls and monitors up to 4 fans
High and low frequency fan drive signal
1 on-chip and 2 remote temperature sensors
Extended temperature measurement range up to 191°C
Automatic fan speed control mode controls system cooling
based on measured temperature
Enhanced acoustic mode dramatically reduces user
perception of changing fan speeds
Thermal protection feature via THERM output
Monitors performance impact of Intel® Pentium™ 4
processor
Thermal control circuit via THERM input
3-wire and 4-wire fan speed measurement
Limit comparison of all monitored values
Meets SMBus 2.0 electrical specifications
The ADT7476 dBCool controller is a thermal monitor
and multiple PWM fan controller for noise-sensitive or powersensitive applications requiring active system cooling. The
ADT7476 can drive a fan using either a low or high frequency
drive signal, monitor the temperature of up to two remote
sensor diodes plus its own internal temperature, and measure
and control the speed of up to four fans, so they operate at
the lowest possible speed for minimum acoustic noise.
The automatic fan speed control loop optimizes fan speed
for a given temperature. The effectiveness of the system’s
thermal solution can be monitored using the THERM input.
The ADT7476 also provides critical thermal protection to
the system using the bidirectional THERM pin as an output
to prevent system or component overheating.
FUNCTIONAL BLOCK DIAGRAM
ADDREN
VID5
VID4/GPIO4
VID3/GPIO3
VID2/GPIO2
VID1/GPIO1
VID0/GPIO0
GPIO6
PWM1
PWM2
PWM3
ADDR
SELECT SCL SDA SMBALERT
ADT7476
VID/GPIO
REGISTER
PWM
REGISTERS
AND
CONTROLLERS
(HF AND LF)
TACH1
TACH2
TACH3
TACH4
SMBus
ADDRESS
SELECTION
SERIAL BUS
INTERFACE
ADDRESS
POINTER
REGISTER
AUTOMATIC
FAN SPEED
CONTROL
PWM
CONFIGURATION
REGISTERS
INTERRUPT
MASKING
FAN
SPEED
COUNTER
PERFORMANCE
MONITORING
THERMAL
PROTECTION
THERM
VCC
VCC TO ADT7476
ACOUSTIC
ENHANCEMENT
CONTROL
D1+
INTERRUPT
STATUS
REGISTERS
D1–
INPUT
SIGNAL
CONDITIONING
AND
ANALOG
MULTIPLEXER
D2+
D2–
+5VIN
+12VIN
+2.5VIN
10-BIT
ADC
BAND GAP
REFERENCE
VCCP
VALUE AND
LIMIT
REGISTERS
05382-001
BAND GAP
TEMP. SENSOR
LIMIT
COMPARATORS
GND
Figure 1.
Rev. A
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113
©2006 Analog Devices, Inc. All rights reserved.
ADT7476
TABLE OF CONTENTS
Features .............................................................................................. 1
Temperature Measurement Method ........................................ 20
General Description ......................................................................... 1
Factors Affecting Diode Accuracy........................................... 22
Functional Block Diagram .............................................................. 1
Additional ADC Functions for Temperature
Measurement .............................................................................. 23
Table of Contents .............................................................................. 2
Revision History ............................................................................... 3
Specifications..................................................................................... 4
Timing Diagram ........................................................................... 5
Absolute Maximum Ratings............................................................ 6
Thermal Resistance ...................................................................... 6
ESD Caution.................................................................................. 6
Pin Configuration and Function Descriptions............................. 7
Typical Performance Characteristics ............................................. 9
Product Description....................................................................... 11
Feature Comparisons Between ADT7476 and ADT7468..... 11
Recommended Implementation............................................... 12
Serial Bus Interface..................................................................... 13
Write Operations ........................................................................ 15
Read Operations ......................................................................... 16
SMBus Timeout .......................................................................... 16
Virus Protection.......................................................................... 16
Voltage Measurement Input...................................................... 17
Limits, Status Registers, and Interrupts....................................... 25
Limit Values ................................................................................ 25
Status Registers ........................................................................... 26
THERM Timer ........................................................................... 28
Fan Drive Using PWM Control ............................................... 31
Laying Out 3-Wire Fans ............................................................ 33
Programming TRANGE.................................................................. 36
Programming the Automatic Fan Speed Control Loop ............ 37
Manual Fan Control Overview................................................. 37
THERM Operation in Manual Mode...................................... 37
Automatic Fan Control Overview............................................ 37
Step 1: Hardware Configuration .............................................. 38
Step 2: Configuring the Mux .................................................... 41
Step 3: TMIN Settings for Thermal Calibration Channels ...... 43
Step 4: PWMMIN for Each PWM (Fan) Output ...................... 44
Step 5: PWMMAX for PWM (Fan) Outputs.............................. 45
Step 6: TRANGE for Temperature Channels................................ 46
Analog-to-Digital Converter .................................................... 17
Step 7: TTHERM for Temperature Channels ............................... 48
Input Circuitry............................................................................ 17
Step 8: THYST for Temperature Channels.................................. 50
Voltage Measurement Registers................................................ 17
Fan Presence Detect................................................................... 51
Voltage Limit Registers .............................................................. 17
Fan Sync....................................................................................... 52
Extended Resolution Registers ................................................. 17
Standby Mode ............................................................................. 52
Additional ADC Functions for Voltage Measurements ........ 17
XNOR Tree Test Mode .............................................................. 52
VID Code Monitoring ............................................................... 20
Power-On Default ...................................................................... 52
VID Code Input Threshold Voltage......................................... 20
Register Tables ................................................................................ 53
VID Code Change Detect Function ........................................ 20
Outline Dimensions ....................................................................... 72
Programming the GPIOs........................................................... 20
Ordering Guide .......................................................................... 72
Rev. A | Page 2 of 72
ADT7476
REVISION HISTORY
3/06—Rev. 0 to Rev. A
Changes to Features Section ............................................................1
Changes to Table 1 ............................................................................4
Inserted Table 3..................................................................................6
Changes to Feature Comparisons Between ADT7476 and
ADT7468 Section ............................................................................11
Changes to Figure 23 ......................................................................16
Changes to Fan Speed Measurement Registers Section.............34
Changes to Register Tables Section...............................................53
Changes to Ordering Guide...........................................................72
4/05—Revision 0: Initial Version
Rev. 0 | Page 3 of 72
ADT7476
SPECIFICATIONS
TA = TMIN to TMAX, VCC = VMIN to VMAX, unless otherwise noted. 1
Table 1.
Parameter
POWER SUPPLY
Supply Voltage
Supply Current, ICC
TEMPERATURE-TO-DIGITAL CONVERTER
Local Sensor Accuracy
Min
Typ
Max
Unit
Test Conditions/Comments
3.0
3.3
1.5
3.6
3
V
mA
Interface inactive, ADC active
±0.5
±1.5
±2.5
°C
°C
°C
°C
°C
°C
μA
μΑ
0°C ≤ TA ≤ 85°C
–40°C ≤ TA ≤ 125°C
%
%
LSB
%/V
ms
ms
ms
ms
ms
kΩ
kΩ
For 12 V channel
For all other channels
8 bits
Averaging enabled
Averaging enabled
Averaging enabled
Averaging enabled
Averaging disabled
For VCCP channel
For all other channels
%
%
0°C ≤ TA ≤ 70°C
−40°C ≤ TA ≤ +120°C
RPM
RPM
RPM
RPM
Fan count = 0xBFFF
Fan count = 0x3FFF
Fan count = 0x0438
Fan count = 0x021C
0.1
8.0
0.4
20
mA
V
μA
IOUT = −8.0 mA
VOUT = VCC
0.1
0.4
1.0
V
μA
IOUT = −4.0 mA
VOUT = VCC
Resolution
Remote Diode Sensor Accuracy
0.25
±0.5
Resolution
Remote Sensor Source Current
0.25
180
11
ANALOG-TO-DIGITAL CONVERTER
(INCLUDING MUX AND ATTENUATORS)
Total Unadjusted Error (TUE)
Differential Nonlinearity (DNL)
Power Supply Sensitivity
Conversion Time (Voltage Input)
Conversion Time (Local Temperature)
Conversion Time (Remote Temperature)
Total Monitoring Cycle Time
Total Monitoring Cycle Time
Input Resistance
±2
±1.5
±1
70
70
±0.1
11
12
38
145
19
120
114
FAN RPM-TO-DIGITAL CONVERTER
Accuracy
Full-Scale Count
Nominal Input RPM
OPEN-DRAIN DIGITAL OUTPUTS, PWM1 TO PWM3,
XTO
Current Sink, IOL
Output Low Voltage, VOL
High Level Output Current, IOH
OPEN-DRAIN SERIAL DATA BUS OUTPUT (SDA)
Output Low Voltage, VOL
High Level Output Current, IOH
±1.5
±2.5
±6
±10
65,535
109
329
5000
10,000
Rev. A | Page 4 of 72
0°C ≤ TA ≤ 85°C
–40°C ≤ TA ≤ 125°C
High level
Low level
ADT7476
Parameter
SMBUS DIGITAL INPUTS (SCL, SDA)
Input High Voltage, VIH
Input Low Voltage, VIL
Hysteresis
DIGITAL INPUT LOGIC LEVELS (TACH INPUTS)
Input High Voltage, VIH
Min
Typ
Max
Unit
0.4
V
V
mV
2.0
500
2.0
V
V
3.6
Input Low Voltage, VIL
0.8
V
V
V p-p
−0.3
Hysteresis
DIGITAL INPUT LOGIC LEVELS (THERM) ADTL+
Input High Voltage, VIH
Input Low Voltage, VIL
DIGITAL INPUT CURRENT
Input High Current, IIH
Input Low Current, IIL
Input Capacitance, CIN
SERIAL BUS TIMING 2
Clock Frequency, fSCLK
Glitch Immunity, tSW
Bus Free Time, tBUF
SCL Low Time, tLOW
SCL High Time, tHIGH
SCL, SDA Rise Time, tr
SCL, SDA Fall Time, tf
Data Setup Time, tSU;DAT
Detect Clock Low Timeout, tTIMEOUT
0.5
0.75 × VCC
0.4
±1
±1
5
Test Conditions/Comments
Maximum input voltage
Minimum input voltage
V
V
μA
μA
pF
VIN = VCC
VIN = 0
See Figure 2
10
400
50
4.7
4.7
4.0
kHz
ns
μs
μs
μs
ns
μs
ns
ms
50
1000
300
250
15
35
Can be disabled
1
All voltages are measured with respect to GND, unless otherwise specified. Typical voltages are TA = 25°C and represent a most likely parametric norm. Logic inputs
accept input high voltages up to VMAX, even when the device is operating down to VMIN. Timing specifications are tested at logic levels of VIL = 0.8 V for a falling edge,
and VIH = 2.0 V for a rising edge.
2
SMBus timing specifications are guaranteed by design and are not production tested.
TIMING DIAGRAM
tLOW
tR
tF
tHD; STA
SCL
SDA
tHD; DAT
tHIGH
tBUF
P
tSU; STA
tSU; DAT
S
S
Figure 2. Serial Bus Timing Diagram
Rev. A | Page 5 of 72
tSU; STO
P
05382-002
tHD; STA
ADT7476
ABSOLUTE MAXIMUM RATINGS
Table 2.
Parameter
Positive Supply Voltage (VCC)
Maximum Voltage on +12VIN Pin
Maximum Voltage on +5VIN Pin
Maximum Voltage on All Open-Drain Outputs
Voltage on Any Input or Output Pin
Input Current at Any Pin
Package Input Current
Maximum Junction Temperature (TJ MAX)
Storage Temperature Range
Lead Temperature, Soldering
IR Reflow Peak Temperature
Pb-Free Peak Temperature
Lead Temperature (Soldering, 10 sec)
ESD rating
Rating
3.6 V
16 V
6.25V
3.6 V
−0.3 V to +4.2 V
±5 mA
±20 mA
150°C
−65°C to
+150°C
220°C
260°C
300°C
1500 V
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
THERMAL RESISTANCE
θJA is specified for the worst-case conditions, that is, a device
soldered in a circuit board for surface-mount packages.
Table 3. Thermal Resistance
Package Type
24-Lead QSOP
θJA
122
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
Rev. A | Page 6 of 72
θJC
31.25
Unit
°C/W
ADT7476
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
SDA 1
24 PWM1/XTO
SCL 2
23 VCCP
GND 3
22 +2.5VIN/THERM
21 +12VIN/VID5
VCC 4
VID0/GPIO0 5
VID1/GPIO1 6
VID2/GPIO2 7
ADT7476
20 +5VIN
TOP VIEW
19 VID4/GPIO4
(Not to Scale)
18 D1+
VID3/GPIO3 8
17 D1–
TACH3 9
16 D2+
PWM2/SMBALERT 10
15 D2–
14 TACH4/THERM/SMBALERT/GPIO6/ADDR SELECT
TACH2 12
13 PWM3/ADDREN
05382-003
TACH1 11
Figure 3. Pin Configuration
Table 4. Pin Function Descriptions
Pin No.
1
2
3
4
Mnemonic
SDA
SCL
GND
VCC
5
VID0
GPIO0
VID1
GPIO1
VID2
GPIO2
VID3
GPIO3
TACH3
PWM2
6
7
8
9
10
SMBALERT
11
12
13
TACH1
TACH2
PWM3
ADDREN
14
TACH4
THERM
SMBALERT
15
GPIO6
ADDR SELECT
D2–
Description
Digital I/O (Open Drain). SMBus bidirectional serial data. Requires SMBus pull-up.
Digital Input (Open Drain). SMBus serial clock input. Requires SMBus pull-up.
Ground Pin.
Power Supply. Powered by 3.3 V standby, if monitoring in low power states is required. VCC is also monitored
through this pin.
Digital Input. Voltage supply readouts from CPU. This value is read into the VID register (0x43).
General-Purpose Open-Drain Digital I/O.
Digital Input. Voltage supply readouts from CPU. This value is read into the VID register (0x43).
General-Purpose Open-Drain Digital I/O.
Digital Input. Voltage supply readouts from CPU. This value is read into the VID register (0x43).
General-Purpose Open-Drain Digital I/O.
Digital Input. Voltage supply readouts from CPU. This value is read into the VID register (0x43).
General-Purpose Open-Drain Digital I/O.
Digital Input (Open Drain). Fan tachometer input to measure speed of Fan 3.
Digital Output (Open Drain). Requires 10 kΩ typical pull-up. Pulse-width modulated output to control Fan 2
speed. Can be configured as a high or low frequency drive.
Digital Output (Open Drain). This pin can be reconfigured as an SMBALERT interrupt output to signal out-oflimit conditions.
Digital Input (Open Drain). Fan tachometer input to measure speed of Fan 1.
Digital Input (Open Drain). Fan tachometer input to measure speed of Fan 2.
Digital I/O (Open Drain). Pulse-width modulated output to control Fan 3 and Fan 4 speed. Requires 10 kΩ typical
pull-up. Can be configured as a high or low frequency drive.
If pulled low on power-up, the ADT7476 enters address select mode, and the state of Pin 14 (ADDR SELECT)
determines the ADT7476 slave address.
Digital Input (Open Drain). Fan tachometer input to measure speed of Fan 4.
Alternatively, the pin can be reconfigured as a bidirectional THERM pin. Use to time and monitor assertions on
the THERM input. For example, can be connected to the PROCHOT output of an Intel Pentium 4 processor or to
the output of a trip point temperature sensor. Can be used as an output to signal overtemperature conditions.
Digital Output (Open Drain). This pin can be reconfigured as an SMBALERT interrupt output to signal out-oflimit conditions.
General-Purpose Open-Drain Digital I/O.
If in address select mode, the logic state of this pin defines the SMBus device address.
Cathode Connection to Second Thermal Diode.
Rev. A | Page 7 of 72
ADT7476
Pin No.
16
17
18
19
20
21
22
23
24
Mnemonic
D2+
D1–
D1+
VID4
GPIO4
+5VIN
+12VIN
VID5
+2.5VIN
THERM
VCCP
PWM1
XTO
Description
Anode Connection to Second Thermal Diode.
Cathode Connection to First Thermal Diode.
Anode Connection to First Thermal Diode.
Digital Input. Voltage supply readouts from CPU. This value is read into the VID register (0x43).
General-Purpose Open-Drain Digital I/O.
Analog Input. Monitors +5 V power supply.
Analog Input. Monitors +12 V power supply.
Digital Input. Voltage supply readouts from CPU. This value is read into the VID register (0x43).
Analog Input. Monitors +2.5 V supply, typically a chipset voltage.
Alternatively, this pin can be reconfigured as a bidirectional/omnidirectional THERM pin. Can be used to time
and monitor assertions on the THERM input. For example, can be connected to the PROCHOT output of an Intel
Pentium 4 processor or to the output of a trip point temperature sensor. Can be used as an output to signal
overtemperature conditions.
Analog Input. Monitors processor core voltage (0 V to 3 V).
Digital Output (Open Drain). Pulse-width modulated output to control Fan 1 speed. Requires 10 kΩ typical
pull-up.
Also functions as the output from the XOR tree in XOR test mode.
Rev. A | Page 8 of 72
ADT7476
TYPICAL PERFORMANCE CHARACTERISTICS
70
0
60
TEMPERATURE ERROR (°C)
–20
–30
–40
–50
0
2
4
6
8
10
14
12
16
18
20
40
30
100mV
20
60mV
40mV
10
0
05382-004
–60
50
–10
22
05382-008
TEMPERATURE ERROR (°C)
–10
0
100M
200M
300M
400M
500M
600M
NOISE FREQUENCY (Hz)
CAPACITANCE (nF)
Figure 4. Temperature Error vs. Capacitance Between D+ and D−
Figure 7. Remote Temperature Error vs. Differential Mode Noise Frequency
30
1.20
1.18
1.16
1.14
10
D+ TO GND
1.12
0
IDD (mA)
D+ TO VCC
–10
1.10
1.08
1.06
–20
1.04
1.02
05382-006
–30
–40
0
20
40
60
80
05382-009
TEMPERATURE ERROR (°C)
20
1.00
0.98
3.0
100
3.1
3.2
LEAKAGE RESISTANCE (MΩ)
Figure 5. Remote Temperature Error vs. PCB Resistance
3.6
500M
600M
15
25
10
100mV
TEMPERATURE ERROR (°C)
20
15
60mV
10
5
5
100mV
0
250mV
–5
–10
05382-007
0
40mV
0
100M
200M
300M
400M
500M
05382-010
TEMPERATURE ERROR (°C)
3.5
3.4
Figure 8. Normal IDD vs. Power Supply
30
–5
3.3
VDD (V)
–15
0
600M
100M
200M
300M
400M
FREQUENCY (Hz)
NOISE FREQUENCY (Hz)
Figure 6. Remote Temperature Error vs. Common-Mode Noise Frequency
Rev. A | Page 9 of 72
Figure 9. Internal Temperature Error vs. Power Supply
ADT7476
3.0
6
2.5
250mV
2
TEMPERATURE ERROR (°C)
0
–2
100mV
–4
–6
–8
1.5
1.0
0.5
0
–0.5
–1.0
05382-011
–10
–12
0
100M
200M
300M
400M
500M
–1.5
–2.0
–40
600M
Figure 10. Remote Temperature Error vs. Power Supply Noise Frequency
3.0
2.5
2.0
1.5
1.0
0.5
0
–0.5
05382-012
–1.0
–1.5
–40
–20
0
20
40
60
–20
0
20
40
60
85
105
125
OIL BATH TEMPERATURE (°C)
FREQUENCY (Hz)
TEMPERATURE ERROR (°C)
2.0
05382-013
TEMPERATURE ERROR (°C)
4
85
105
125
OIL BATH TEMPERATURE (°C)
Figure 11. Internal Temperature Error vs. Temperature
Rev. A | Page 10 of 72
Figure 12. Remote Temperature Error vs. Temperature
ADT7476
PRODUCT DESCRIPTION
The ADT7476 is a complete thermal monitor and multiple fan
controller for any system requiring thermal monitoring and
cooling. The device communicates with the system via a serial
system management bus. The serial bus controller has a serial
data line for reading and writing addresses and data (Pin 1),
and an input line for the serial clock (Pin 2). All control and
programming functions for the ADT7476 are performed over
the serial bus. In addition, a pin can be reconfigured as an
SMBALERT output to signal out-of-limit conditions.
FEATURE COMPARISONS BETWEEN ADT7476
AND ADT7468
•
•
Dynamic TMIN , dynamic operating point, and associated
registers are no longer available on the ADT7476. The
following related registers are not available in the
ADT7476:
•
For the ADT7476, acoustic filtering is now assigned to
temperature zones and not to fans. Smoothing times have
been increased for better acoustic performance.
•
For the ADT7476, temperature measurements are made
with two switching currents instead of three. SRC is not
available in the ADT7476.
•
For the ADT7476, high frequency PWM can now be
enabled/disabled on each PWM output individually.
•
For the ADT7476, THERM can now be enabled/disabled
on each temperature channel individually.
•
The ADT7476 does not support full shutdown mode.
•
The ADT7476 defaults to twos complement temperature
measurement mode.
•
Some pins have swapped/added functions.
•
Calibration Control 1 and Calibration Control 2
(Register 0x36 and Register 0x37)
•
The power-up routine for the ADT7476 is simplified.
•
Operating Point (Register 0x33, Register 0x34, and
Register 0x35)
Other minor changes in the ADT7476 include the following:
Previously, TRANGE defined the slope of the automatic fan
control algorithm. For the ADT7476, TRANGE now defines a
true temperature range.
•
Vcore_low_enable has been reallocated to Bit 7 of
Configuration Register 1 (0x40).
•
Dev ID register reads 0x76.
Rev. A | Page 11 of 72
ADT7476
RECOMMENDED IMPLEMENTATION
•
Configuring the ADT7476, as shown in Figure 13, allows the
system designer to use the following features:
Remote temperature zone measured through Remote 2
temperature channel.
•
Local temperature zone measured through the internal
temperature channel.
•
Bidirectional THERM pin. This feature allows Intel
Pentium 4 PROCHOT monitoring and can function as an
overtemperature THERM output. It can alternatively be
programmed as an SMBALERT system interrupt output.
•
Two PWM outputs for fan control of up to three fans. (The
front and rear chassis fans are connected in parallel.)
•
Three TACH fan speed measurement inputs.
•
VCC measured internally through Pin 4.
•
CPU temperature measured using Remote 1 temperature
channel.
ADT7476
FRONT
CHASSIS
FAN
REAR
CHASSIS
FAN
PWM1
TACH2
TACH1
PWM3
TACH3
5(VRM9)/6(VRM10)
VID[0:4]/VID[0:5]
D2+
D2–
THERM
PROCHOT
D1+
D1–
VCC
SDA
+5VIN
SCL
+12VIN/VID5 SMBALERT
GND
Figure 13. ADT7476 Configuration
Rev. A | Page 12 of 72
05382-014
AMBIENT
TEMPERATURE
ADT7476
VCC
SERIAL BUS INTERFACE
ADT7476
Control of the ADT7476 is carried out using the serial system
management bus (SMBus). The ADT7476 is connected to this
bus as a slave device, under the control of a master controller.
The ADT7476 has a 7-bit serial bus address. When the device
is powered up with Pin 13 (PWM3/ADDREN) high, the
ADT7476 has a default SMBus address of 0101110 or 0x2E.
The read/write bit must be added to get the 8-bit address.
If more than one ADT7476 is used in a system, each ADT7476
is placed in ADDR SELECT mode by strapping Pin 13 low on
power-up. The logic state of Pin 14 then determines the device’s
SMBus address. The logic of these pins is sampled on power-up.
ADDR SELECT
PWM3/ADDREN
10kΩ
14
13
NC
DO NOT LEAVE ADDREN
UNCONNECTED! CAN
CAUSE UNPREDICTABLE
ADDRESSES.
NOTE THAT IF THE ADT7476 IS PLACED INTO ADDR SELECT
MODE, PINS 13 AND 14 CANNOT BE USED AS THE ALTERNATIVE
FUNCTIONS (PWM3, TACH4/THERM) UNLESS THE CORRECT
CIRCUIT IS MUXED IN AT THE CORRECT TIME OR DESIGNED TO
HANDLE THESE DUAL FUNCTIONS.
05382-018
CARE SHOULD BE TAKEN TO ENSURE THAT PIN 13
(PWM3/ADDREN) IS EITHER TIED HIGH OR LOW. LEAVING PIN 13
FLOATING COULD CAUSE THE ADT7476 TO POWER UP WITH AN
UNEXPECTED ADDRESS.
Figure 17. Unpredictable SMBus Address if Pin 13 Is Unconnected
The device address is sampled on power-up and latched on
the first valid SMBus transaction, more precisely on the low-tohigh transition at the beginning of the 8th SCL pulse, when the
serial bus address byte matches the selected slave address.
The selected slave address is chosen using the ADDREN pin/
ADDR SELECT pin. Any attempted changes in the address
have no effect after this.
The ability to make hardwired changes to the SMBus slave
address allows the user to avoid conflicts with other devices
sharing the same serial bus, for example, if more than one
ADT7476 is used in a system.
Table 5. Hardwiring the ADT7476 SMBus Device Address
1.
The master initiates data transfer by establishing a start
condition, defined as a high-to-low transition on the serial
data line SDA while the serial clock line SCL remains high.
This indicates an address/data stream follows. All slave
peripherals connected to the serial bus respond to the start
condition and shift in the next eight bits, consisting of a
7-bit address (MSB first), plus a R/W bit that determines
the direction of the data transfer, that is, whether data is
written to or read from the slave device.
2.
The peripheral whose address corresponds to the transmitted address responds by pulling the data line low during
the low period before the ninth clock pulse, known as the
acknowledge bit. All other devices on the bus now remain
idle while the selected device waits for data to be read from
or written to it. If the R/W bit is a 0, the master writes to
the slave device. If the R/W bit is a 1, the master reads from
the slave device.
3.
Data is sent over the serial bus in sequences of nine clock
pulses, eight bits of data followed by an acknowledge bit
from the slave device. Transitions on the data line must
occur during the low period of the clock signal and
remain stable during the high period. A low-to-high
transition, when the clock is high, can be interpreted
as a stop signal. The number of data bytes transmitted
over the serial bus in a single read or write operation is
limited only by what the master and slave devices
can handle.
Pin 14
Low (10 kΩ to GND)
High (10 kΩ Pull-Up)
Don’t Care
VCC
ADT7476
PWM3/ADDREN
14
10kΩ
13
ADDRESS = 0x2E
05382-015
ADDR SELECT
Address
0101100 (0x2C)
0101101 (0x2D)
0101110 (0x2E)
Figure 14. Default SMBus Address = 0x2E
ADT7476
PWM3/ADDREN
14 10kΩ
13
ADDRESS = 0x2C
05382-016
ADDR SELECT
Figure 15. SMBus Address = 0x2C (Pin 14 = 0)
VCC
ADT7476
ADDR SELECT
PWM3/ADDREN
10kΩ
14
13
ADDRESS = 0x2D
05382-017
Pin 13 State
0
0
1
The serial bus protocol operates as follows:
Figure 16. SMBus Address = 0x2D (Pin 14 = 1)
Rev. A | Page 13 of 72
ADT7476
When all data bytes have been read or written, stop
conditions are established. In write mode, the master pulls
the data line high during the 10th clock pulse to assert a
stop condition.
On PCs and servers, control of the ADT7476 is carried out using
the SMBus. The ADT7476 is connected to this bus as a slave
device, under the control of a master controller, which is usually
(but not necessarily) the ICH.
In read mode, the master device overrides the acknowledge
bit by pulling the data line high during the low period before
the ninth clock pulse. This is known as No Acknowledge.
The master then takes the data line low during the low
period before the 10th clock pulse, and then high during
the 10th clock pulse to assert a stop condition. Any number
of bytes of data can be transferred over the serial bus in one
operation. It is not possible to mix read and write in one
operation because the type of operation is determined at
the beginning and cannot subsequently be changed without starting a new operation. For the ADT7476, write
operations contain either one or two bytes, and
read operations contain one byte and perform the
following functions.
The ADT7476 has three 7-bit serial bus addresses. The R/W bit
must be added to get the 8-bit address (that is, 01011100 or
0x5C). Data is sent over the serial bus in sequences of nine clock
pulses: eight bits of data followed by an acknowledge bit from the
slave device. Transitions on the data line must occur during the
low period of the clock signal and remain stable during the high
period, because a low-to-high transition when the clock is high
might be interpreted as a stop signal. The number of data bytes
transmitted over the serial bus in a single read or write operation is limited only by what the master and slave devices
can handle.
When reading data from a register, there are two possibilities:
•
To write data to one of the device data registers or read
data from it, the address pointer register must be set, so
the correct data register is addressed, then data can be
written into that register or read from it. The first byte
of a write operation always contains an address stored in
the address pointer register. If data is to be written to the
device, the write operation contains a second data byte
that is written to the register selected by the address
pointer register (see Figure 18).
If the ADT7476 address pointer register value is unknown,
or not the desired value, it must first be set to the correct
value before data can be read from the desired data
register. This is done by performing a write to the
ADT7476 as before, but only the data byte containing the
register address is sent, because no data is written to the
register (see Figure 19).
A read operation is then performed consisting of the serial
bus address, R/W bit set to 1, followed by the data byte
read from the data register (see Figure 20.)
•
The device address is sent over the bus followed by the
R/W bit being set to 0. This is followed by two data bytes.
The first data byte is the address of the internal data
register to be written to, which is stored in the address
pointer register. The second data byte is the data to be
written to the internal data register.
1
9
If the address pointer register is already at the desired
address, data can be read from the corresponding data
register without first writing to the address pointer register
(see Figure 20).
9
1
SCL
SDA
0
1
0
1
1
A1
A0
D7
R/W
START BY
MASTER
D6
ACK. BY
ADT7476
FRAME 1
SERIAL BUS ADDRESS BYTE
D5
D4
D3
D2
D1
D0
ACK. BY
ADT7476
FRAME 2
ADDRESS POINTER REGISTER BYTE
1
9
SCL (CONTINUED)
SDA (CONTINUED)
D7
D6
D5
D4
D3
D2
FRAME 3
DATA BYTE
D1
D0
ACK. BY STOP BY
ADT7476 MASTER
Figure 18. Writing a Register Address to the Address Pointer Register, then Writing Data to the Selected Register
Rev. A | Page 14 of 72
05382-019
4.
ADT7476
1
9
9
1
SCL
0
1
START BY
MASTER
0
1
1
A1
A0
D7
R/W
D6
ACK. BY
ADT7476
FRAME 1
SERIAL BUS ADDRESS BYTE
D4
D5
D2
D3
D1
D0
ACK. BY
ADT7476
FRAME 2
ADDRESS POINTER REGISTER BYTE
STOP BY
MASTER
05382-020
SDA
Figure 19. Writing to the Address Pointer Register Only
1
9
9
1
SCL
0
1
START BY
MASTER
0
1
1
A1
A0
R/W
FRAME 1
SERIAL BUS ADDRESS BYTE
D7
D6
ACK. BY
ADT7476
D5
D4
D2
D3
D1
FRAME 2
DATA BYTE FROM ADT7476
D0
NO ACK. BY STOP BY
MASTER
MASTER
05382-021
SDA
Figure 20. Reading Data from a Previously Selected Register
Send Byte
It is possible to read a data byte from a data register without
first writing to the address pointer register, if the address
pointer register is already at the correct value. However, it is
not possible to write data to a register without writing to the
address pointer register, because the first data byte of a write
is always written to the address pointer register.
In this operation, the master device sends a single command
byte to a slave device, as follows:
1.
The master device asserts a start condition on SDA.
2.
In addition to supporting the send byte and receive byte
protocols, the ADT7476 also supports the read byte protocol.
(See System Management Bus Specifications Rev. 2 for
more information; this document is available from Intel.)
The master sends the 7-bit slave address followed by
the write bit (active low).
3.
The addressed slave device asserts ACK on SDA.
4.
The master sends a command code.
If several read or write operations must be performed in
succession, the master can send a repeat start condition
instead of a stop condition to begin a new operation.
5.
The slave asserts ACK on SDA.
6.
The master asserts a stop condition on SDA, and the
transaction ends.
WRITE OPERATIONS
S – START
P – STOP
R – READ
W – WRITE
A – ACKNOWLEDGE
A – NO ACKNOWLEDGE
The ADT7476 uses the following SMBus write protocols.
For the ADT7476, the send byte protocol is used to write a
register address to RAM for a subsequent single-byte read
from the same address. This operation is illustrated in Figure 21.
1
2
3
SLAVE
S
W A
ADDRESS
4
5 6
REGISTER
ADDRESS
A P
05382-022
The SMBus specification defines several protocols for different
types of read and write operations. The ones used in the
ADT7476 are discussed below. The following abbreviations
are used in the diagrams:
Figure 21. Setting a Register Address for Subsequent Read
If the master is required to read data from the register immediately after setting up the address, it can assert a repeat start
condition immediately after the final ACK and carry out a
single-byte read without asserting an intermediate stop
condition.
Rev. A | Page 15 of 72
ADT7476
Write Byte
Alert Response Address
In this operation, the master device sends a command byte
and one data byte to the slave device, as follows:
Alert response address (ARA) is a feature of SMBus devices that
allows an interrupting device to identify itself to the host when
multiple devices exist on the same bus.
1.
The master device asserts a start condition on SDA.
2.
The master sends the 7-bit slave address followed by
the write bit (active low).
3.
The addressed slave device asserts ACK on SDA.
4.
The master sends a command code.
5.
The slave asserts ACK on SDA.
6.
The master sends a data byte.
7.
The slave asserts ACK on SDA.
8.
The master asserts a stop condition on SDA,
and the transaction ends.
The SMBALERT output can be used as either an interrupt
output or an SMBALERT. One or more outputs can be connected to a common SMBALERT line connected to the master.
If a device’s SMBALERT line goes low, the following procedure
occurs:
1.
SMBALERT is pulled low.
2.
The master initiates a read operation and sends the alert
response address (ARA = 0001 100). This is a general call
address that must not be used as a specific device address.
3.
The device whose SMBALERT output is low responds to
the alert response address, and the master reads its device
address. The address of this device is now known and can
be interrogated in the usual way.
4.
If more than one device’s SMBALERT output is low, the
one with the lowest device address has priority in accordance with normal SMBus arbitration.
5.
Once the ADT7476 has responded to the alert response
address, the master must read the status registers, and
the SMBALERT is cleared only if the error condition
is gone.
1
2
3
SLAVE
S ADDRESS W A
4
5
6
7 8
REGISTER
ADDRESS
A
DATA
A P
05382-023
This operation is illustrated in Figure 22.
Figure 22. Single-Byte Write to a Register
READ OPERATIONS
The ADT7476 uses the following SMBus read protocols.
Receive Byte
This operation is useful when repeatedly reading a single
register. The register address is set up previously. In this
operation, the master device receives a single byte from a
slave device, as follows:
SMBus TIMEOUT
1.
The master device asserts a start condition on SDA.
2.
The master sends the 7-bit slave address followed by the
read bit (high).
3.
The addressed slave device asserts ACK on SDA.
4.
The master receives a data byte.
5.
The master asserts NO ACK on SDA.
6.
The master asserts a stop condition on SDA, and the
transaction ends.
Configuration Register 1 (0x40)
Bit 6 TODIS = 0, SMBus timeout enabled (default)
Bit 6 TODIS = 1, SMBus timeout disabled
VIRUS PROTECTION
2
3
SLAVE
S ADDRESS R A
4
5 6
DATA
A P
05382-024
In the ADT7476, the receive byte protocol is used to read a
single byte of data from a register whose address has previously
been set by a send byte or write byte operation. This operation
is illustrated in Figure 23.
1
The ADT7476 includes an SMBus timeout feature. If there is
no SMBus activity for 35 ms, the ADT7476 assumes the bus
is locked and releases the bus. This prevents the device from
locking or holding the SMBus expecting data. Some SMBus
controllers cannot handle the SMBus timeout feature, so it
can be disabled.
To prevent rogue programs or viruses from accessing critical
ADT7476 register settings, the lock bit can be set. Setting Bit 1
of Configuration Register 1 (0x40) sets the lock bit and locks
critical registers. In this mode, certain registers can no longer be
written to until the ADT7476 is powered down and powered up
again. For more information on which registers are locked, see
the Register Tables section.
Figure 23. Single-Byte Read from a Register
Rev. A | Page 16 of 72
ADT7476
VOLTAGE MEASUREMENT INPUT
VOLTAGE LIMIT REGISTERS
The ADT7476 has four external voltage measurement channels.
It can also measure its own supply voltage, VCC. Pin 20 to Pin 23
can measure 5 V, 12 V, and 2.5 V supplies, and the processor
core voltage VCCP (0 V to 3 V input). The VCC supply voltage
measurement is carried out through the VCC pin (Pin 4). The
2.5 V input can be used to monitor a chipset supply voltage in
computer systems.
Associated with each voltage measurement channel is a high
and low limit register. Exceeding the programmed high or low
limit causes the appropriate status bit to be set. Exceeding either
limit can also generate SMBALERT interrupts.
ANALOG-TO-DIGITAL CONVERTER
Register 0x46, VCCP Low Limit = 0x00 default
All analog inputs are multiplexed into the on-chip, successiveapproximation, analog-to-digital converter. This has a
resolution of 10 bits. The basic input range is 0 V to 2.25 V, but
the inputs have built-in attenuators to allow measurement of
2.5 V, 3.3 V, 5 V, 12 V, and the processor core voltage VCCP
without any external components. To allow the tolerance of
these supply voltages, the ADC produces an output of 3/4 full
scale (768 dec or 300 hex) for the nominal input voltage, and so
has adequate headroom to deal with overvoltages.
Register 0x47, VCCP High Limit = 0xFF default
INPUT CIRCUITRY
Register 0x4D, 12 V High Limit = 0xFF default
The internal structure for the analog inputs is shown in
Figure 24. The input circuit consists of an input protection
diode, an attenuator, plus a capacitor to form a first-order lowpass filter that gives input immunity to high frequency noise.
Table 9 shows the input ranges of the analog inputs and output
codes of the 10-bit ADC.
12V IN
5VIN
3.3VIN
2.5VIN
VCCP
120kΩ
20kΩ
30pF
47kΩ
30pF
71kΩ
30pF
94kΩ
30pF
Register 0x45, 2.5 V High Limit = 0xFF default
Register 0x48, VCC Low Limit = 0x00 default
Register 0x49, VCC High Limit = 0xFF default
Register 0x4A, 5 V Low Limit = 0x00 default
Register 0x4B, 5 V High Limit = 0xFF default
Register 0x4C, 12 V Low Limit = 0x00 default
When the ADC is running, it samples and converts a voltage
input in 0.7 ms and averages 16 conversions to reduce noise;
a measurement takes nominally 11 ms.
EXTENDED RESOLUTION REGISTERS
93kΩ
Voltage measurements can be made with higher accuracy
using the extended resolution registers (0x76 and 0x77).
Whenever the extended resolution registers are read, the
corresponding data in the voltage measurement registers
(0x20 to 0x24) is locked until their data is read. That is,
if extended resolution is required, the extended resolution
register must be read first immediately followed by
the appropriate voltage measurement register.
68kΩ
MUX
45kΩ
ADDITIONAL ADC FUNCTIONS FOR VOLTAGE
MEASUREMENTS
17.5kΩ
35pF
05382-025
52.5kΩ
Register 0x44, 2.5 V Low Limit = 0x00 default
A number of other functions are available on the ADT7476
to offer the system designer increased flexibility.
Figure 24. Structure of Analog Inputs
Turn-Off Averaging
VOLTAGE MEASUREMENT REGISTERS
Register 0x20, 2.5 V Measurement = 0x00 default
Register 0x21, VCCP Measurement = 0x00 default
Register 0x22, VCC Measurement = 0x00 default
Register 0x23, 5 V Measurement = 0x00 default
For each voltage/temperature measurement read from a value
register, 16 readings have actually been made internally and
the results averaged, before being placed into the value register. When faster conversions are needed, setting Bit 4 of
Configuration Register 2 (0x73) turns averaging off.
This effectively gives a reading 16 times faster, but the reading
can be noisier. The default round-robin cycle time takes 146.5 ms.
Register 0x24, 12 V Measurement = 0x00 default
Rev. A | Page 17 of 72
ADT7476
Table 6. Conversion Time with Averaging Disabled
Channel
Voltage Channels
Remote Temperature 1
Remote Temperature 2
Local Temperature
Measurement Time (ms)
0.7
7
7
1.3
When Bit 7 of Configuration Register 6 (0x10) is set, the default
round-robin cycle time increases to 240 ms.
Bypass All Voltage Input Attenuators
Bit 4 = 1, averaging off.
Bit 5 = 1, bypass input attenuators.
Bit 6 = 1, single-channel convert mode.
TACH1 Minimum High Byte Register (0x55)
Bits [7:5] select ADC channel for single-channel convert mode.
Single-Channel ADC Conversion
Setting Bit 5 of Configuration Register 2 (0x73) removes the
attenuation circuitry from the 2.5 V, VCCP, VCC, 5 V, and 12 V
inputs. This allows the user to directly connect external sensors
or rescale the analog voltage measurement inputs for other
applications. The input range of the ADC without the
attenuators is 0 V to 2.25 V.
Bypass Individual Voltage Input Attenuators
Bits [7:4] of Configuration Register 4 (0x7D) can be used
to bypass individual voltage channel attenuators.
Table 7. Bypassing Individual Voltage Input Attenuators
Using Configuration Register 4 (0x7D)
Bit
4
5
6
7
Configuration Register 2 (0x73)
While single-channel mode is intended as a test mode that
can be used to increase sampling times for a specific channel,
therefore helping to analyze that channel’s performance in
greater detail, it can also have other applications.
Setting Bit 6 of Configuration Register 2 (0x73) places the
ADT7476 into single-channel ADC conversion mode. In this
mode, the ADT7476 can read a single voltage channel only.
The selected voltage input is read every 0.7 ms. The appropriate
ADC channel is selected by writing to Bits [7:5] of the TACH1
minimum high byte register (0x55).
Channel Attenuated
Bypass 2.5 V attenuator
Bypass VCCP attenuator
Bypass 5 V attenuator
Bypass 12 V attenuator
Table 8. Programming Single-Channel ADC Mode
Register 0x55, Bits [7:5]
000
001
010
011
100
101
110
111
1
Channel Selected 1
2.5 V
VCCP
VCC
5V
12 V
Remote 1 temperature
Local temperature
Remote 2 temperature
In the process of configuring single-channel ADC conversion mode, the TACH1 minimum high byte is also changed, possibly trading off TACH1 minimum high byte
functionality with single-channel mode functionality.
Rev. A | Page 18 of 72
ADT7476
Table 9. 10-Bit A/D Output Code vs. VIN
12 VIN
<0.0156
0.0156 to 0.0312
0.0312 to 0.0469
0.0469 to 0.0625
0.0625 to 0.0781
0.0781 to 0.0937
0.0937 to 0.1093
0.1093 to 0.1250
0.1250 to 0.14060
4.0000 to 4.0156
8.0000 to 8.0156
12.0000 to 12.0156
15.8281 to 15.8437
15.8437 to 15.8593
15.8593 to 15.8750
15.8750 to 15.8906
15.8906 to 15.9062
15.9062 to 15.9218
15.9218 to 15.9375
15.9375 to 15.9531
15.9531 to 15.9687
15.9687 to 15.9843
>15.9843
5 VIN
<0.0065
0.0065 to 0.0130
0.0130 to 0.0195
0.0195 to 0.0260
0.0260 to 0.0325
0.0325 to 0.0390
0.0390 to 0.0455
0.0455 to 0.0521
0.0521 to 0.0586
•
•
•
1.6675 to 1.6740
•
•
•
3.3300 to 3.3415
•
•
•
5.0025 to 5.0090
•
•
•
6.5983 to 6.6048
6.6048 to 6.6113
6.6113 to 6.6178
6.6178 to 6.6244
6.6244 to 6.6309
6.6309 to 6.6374
6.6374 to 6.4390
6.6439 to 6.6504
6.6504 to 6.6569
6.6569 to 6.6634
>6.6634
Input Voltage
VCC (3.3 VIN)
<0.0042
0.0042 to 0.0085
0.0085 to 0.0128
0.0128 to 0.0171
0.0171 to 0.0214
0.0214 to 0.0257
0.0257 to 0.0300
0.0300 to 0.0343
0.0343 to 0.0386
2.5 VIN
<0.0032
0.0032 to 0.0065
0.0065 to 0.0097
0.0097 to 0.0130
0.0130 to 0.0162
0.0162 to 0.0195
0.0195 to 0.0227
0.0227 to 0.0260
0.0260 to 0.0292
VCCP
<0.00293
0.0293 to 0.0058
0.0058 to 0.0087
0.0087 to 0.0117
0.0117 to 0.0146
0.0146 to 0.0175
0.0175 to 0.0205
0.0205 to 0.0234
0.0234 to 0.0263
Decimal
0
1
2
3
4
5
6
7
8
1.1000 to 1.1042
0.8325 to 0.8357
0.7500 to 0.7529
256 (¼ scale)
01000000 00
2.2000 to 2.2042
1.6650 to 1.6682
1.5000 to 1.5029
512 (½ scale)
10000000 00
3.3000 to 3.3042
2.4975 to 2.5007
2.2500 to 2.2529
768 (¾ scale)
11000000 00
4.3527 to 4.3570
4.3570 to 4.3613
4.3613 to 4.3656
4.3656 to 4.3699
4.3699 to 4.3742
4.3742 to 4.3785
4.3785 to 4.3828
4.3828 to 4.3871
4.3871 to 4.3914
4.3914 to 4.3957
>4.3957
3.2942 to 3.2974
3.2974 to 3.3007
3.3007 to 3.3039
3.3039 to 3.3072
3.3072 to 3.3104
3.3104 to 3.3137
3.3137 to 3.3169
3.3169 to 3.3202
3.3202 to 3.3234
3.3234 to 3.3267
>3.3267
2.9677 to 2.9707
2.9707 to 2.9736
2.9736 to 2.9765
2.9765 to 2.9794
2.9794 to 2.9824
2.9824 to 2.9853
2.9853 to 2.9882
2.9882 to 2.9912
2.9912 to 2.9941
2.9941 to 2.9970
>2.9970
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
11111101 01
11111101 10
11111101 11
11111110 00
11111110 01
11111110 10
11111110 11
11111111 00
11111111 01
11111111 10
11111111 11
Rev. A | Page 19 of 72
A/D Output
Binary (10 Bits)
00000000 00
00000000 01
00000000 10
00000000 11
00000001 00
00000001 01
00000001 10
00000001 11
00000010 00
ADT7476
VID CODE MONITORING
The ADT7476 has five dedicated voltage ID (VID code) inputs.
These are digital inputs that can be read back through the VID
register (0x43) to determine the processor voltage required or
being used in the system. Five VID code inputs support VRM9.x
solutions. In addition, Pin 21 (12 V input) can be reconfigured as
a sixth VID input to satisfy future VRM requirements.
VID Code Register (0x43)
Bit 0 = VID0, reflects logic state of Pin 5.
Bit 1 = VID1, reflects logic state of Pin 6.
Bit 2 = VID2, reflects logic state of Pin 7.
Bit 3 = VID3, reflects logic state of Pin 8.
Bit 4 = VID4, reflects logic state of Pin 19.
Bit 7 of the VID configuration register (0x43) determines the
function of Pin 21. System or BIOS software can read the state
of Bit 7 to determine whether the system is designed to monitor
12 V or is monitoring a sixth VID input.
VID CODE CHANGE DETECT FUNCTION
The ADT7476 has a VID code change detect function. When
Pin 21 is configured as the VID5 input, VID code changes are
detected and reported back by the ADT7476. Bit 0 of Status
Register 2 (0x42) is the 12 V/VC bit and denotes a VID change
when set. The VID code change bit is set when the logic states
on the VID inputs are different than they were 11 μs previously.
The change of VID code is used to generate an SMBALERT
interrupt. If an SMBALERT interrupt is not required, Bit 0 of
Interrupt Mask Register 2 (0x75), when set, prevents
SMBALERTs from occurring on VID code changes.
Bit 5 = VID5, reconfigurable 12 V input. This bit reads 0 when
Pin 21 is configured as the 12 V input. This bit reflects the logic
state of Pin 21 when the pin is configured as VID5.
Interrupt Status Register 2 (0x42)
VID CODE INPUT THRESHOLD VOLTAGE
Bit 0 12V/VC = 1, if Pin 21 is configured as VID5, Logic 1
means that a change has occurred on the VID code inputs
within the last 11 μs. An SMBALERT is generated if this function is enabled.
The switching threshold for the VID code inputs is approximately 1 V. To enable future compatibility, it is possible to
reduce the VID code input threshold to 0.6 V. Bit 6 (THLD) of
the VID register (0x43) controls the VID input threshold
voltage.
VID Code Register (0x43)
Bit 6 THLD = 0, VID switching threshold = 1 V,
VOL < 0.8 V, VIH > 1.7 V, VMAX = 3.3 V.
Bit 6 THLD = 1, VID switching threshold = 0.6 V,
VOL < 0.4 V, VIH > 0.8 V, VMAX = 3.3 V.
Bit 0 12V/VC = 0, if Pin 21 is configured as VID5, Logic 0
denotes no change in VID code within the last 11 μs.
PROGRAMMING THE GPIOS
The ADT7476 follows an upgrade path from the ADM1027 to
ADT7476. In order to maintain consistency between versions,
it is necessary to omit references to GPIO5. As a result, there
are six GPIOs as follows: GPIO0, GPIO1, GPIO2, GPIO3,
GPIO4, and GPIO6.
Setting Bit 4 of Configuration Register 5 (0x7C) to 1 enables
GPIO functionality. This turns all pins configured as VID
inputs into general-purpose outputs. Writing to the corresponding VID bit in the VID register (0x43) sets the polarity
for the corresponding GPIO. GPIO6 can be programmed
independently as an input/output/etc., using Bits [3:2] of
Configuration Register 5 (0x7C).
Bit 7 VIDSEL = 0, Pin 21 functions as a 12 V measurement
input. Software can read this bit to determine there are five
VID inputs being monitored. Bit 5 of Register 0x43 (VID5)
always reads back 0. Bit 0 of Status Register 2 (0x42) reflects
12 V out-of-limit measurements.
Bit 7 VIDSEL = 1, Pin 21 functions as the sixth VID code input
(VID5). Software can read this bit to determine there are six
VID inputs being monitored. Bit 5 of Register 0x43 reflects the
logic state of Pin 21. Bit 0 of Status Register 2 (0x42) reflects
VID code changes.
Reconfiguring Pin 21 as VID5 Input
Pin 21 can be reconfigured as a sixth VID code input (VID5)
for VRM10 compatible systems. Because the pin is configured
as VID5, it is not possible to monitor a 12 V supply.
TEMPERATURE MEASUREMENT METHOD
Local Temperature Measurement
The ADT7476 contains an on-chip band gap temperature
sensor whose output is digitized by the on-chip, 10-bit ADC.
The 8-bit MSB temperature data is stored in the temperature
registers (Register 0x25, Register 0x26, and Register 0x27).
Because both positive and negative temperatures can be
measured, the temperature data is stored in Offset 64 format or
twos complement format, as shown in Table 10 and Table 11.
Rev. A | Page 20 of 72
ADT7476
Theoretically, the temperature sensor and ADC can measure
temperatures from −63°C to +127°C (or −61°C to +191°C in the
extended temperature range) with a resolution of 0.25°C.
However, this exceeds the operating temperature range of the
device, so local temperature measurements outside the
ADT7476 operating temperature range are not possible.
Remote Temperature Measurement
The ADT7476 can measure the temperature of two remote
diode sensors or diode-connected transistors connected to
Pin 17 and Pin 18, or Pin 15 and Pin 16.
To measure ΔVBE, the sensor is switched between operating
currents of I and N × I. The resulting waveform is passed
through a 65 kHz low-pass filter to remove noise and to a
chopper-stabilized amplifier that performs the functions of
amplification and rectification of the waveform to produce a
dc voltage proportional to ΔVBE. This voltage is measured by
the ADC to give a temperature output in 10-bit, twos complement format. To further reduce the effects of noise, digital
filtering is performed by averaging the results of 16
measurement cycles.
A remote temperature measurement takes nominally 38 ms.
The results of remote temperature measurements are stored in
10-bit, twos complement format, as illustrated in Table 10. The
extra resolution for the temperature measurements is held in
the Extended Resolution Register 2 (0x77). This gives
temperature readings with a resolution of 0.25°C.
The forward voltage of a diode or diode-connected transistor
operated at a constant current exhibits a negative temperature
coefficient of about −2 mV/°C. Unfortunately, the absolute
value of VBE varies from device to device and individual
calibration is required to null this out, so the technique is
unsuitable for mass production. The technique used in the
ADT7476 is to measure the change in VBE when the device
is operated at two different currents.
Noise Filtering
For temperature sensors operating in noisy environments,
previous practice was to place a capacitor across the D+ pin and
the D− pin to help combat the effects of noise. However, large
capacitances affect the accuracy of the temperature measurement,
leading to a recommended maximum capacitor value of 1000 pF.
This is given by
ΔVBE = KT/q × 1n(N)
where:
This capacitor reduces the noise, but does not eliminate it, which
makes it difficult to use of the sensor in a very noisy environment.
In most cases, a capacitor is not required as differential inputs
by their very nature have a high immunity to noise.
K is Boltzmann’s constant.
q is the charge on the carrier.
T is the absolute temperature in Kelvin.
N is the ratio of the two currents.
ADT7476
2N3904
NPN
D+
D–
05382-027
Figure 25 shows the input signal conditioning used to measure
the output of a remote temperature sensor. This figure shows
the external sensor as a substrate transistor, provided for
temperature monitoring on some microprocessors. It could
also be a discrete transistor such as a 2N3904/2N3906.
Figure 26. Measuring Temperature Using an NPN Transistor
VDD
CPU
I
N×I
IBIAS
ADT7476
D+
THERMDC
D–
VOUT+
TO ADC
LOW-PASS FILTER
fC = 65kHz
D+
VOUT–
Figure 25. Signal Conditioning for Remote Diode Temperature Sensors
2N3906
PNP
D–
05382-028
BIAS
DIODE
05382-026
REMOTE
SENSING
TRANSISTOR
THERMDA
Figure 27. Measuring Temperature Using a PNP Transistor
If a discrete transistor is used, the collector is not grounded
and should be linked to the base. If a PNP transistor is used,
the base is connected to the D– input and the emitter to the
D+ input. If an NPN transistor is used, the emitter is connected to the D– input and the base to the D+ input. Figure 26
and Figure 27 show how to connect the ADT7476 to an NPN
or PNP transistor for temperature measurement. To prevent
ground noise from interfering with the measurement, the more
negative terminal of the sensor is not referenced to ground, but
is biased above ground by an internal diode at the D– input.
Rev. A | Page 21 of 72
ADT7476
FACTORS AFFECTING DIODE ACCURACY
Remote Sensing Diode
The ADT7476 is designed to work with either substrate
transistors built into processors or with discrete transistors.
Substrate transistors are generally PNP types with the collector
connected to the substrate. Discrete types can be either PNP
or NPN transistors connected as a diode (base-shorted to the
collector). If an NPN transistor is used, the collector and base
are connected to D+ and the emitter to D−. If a PNP transistor
is used, the collector and base are connected to D− and the
emitter is connected to D+.
To reduce the error due to variations in both substrate and
discrete transistors, a number of factors should be taken
into consideration:
•
The ideality factor, nf, of the transistor is a measure of the
deviation of the thermal diode from ideal behavior. The
ADT7476 is trimmed for an nf value of 1.008. Use the
following equation to calculate the error introduced at a
temperature T (°C), when using a transistor whose nf
does not equal 1.008. See the processor data sheet for
the nf values.
ΔT = (nf − 1.008) × (273.15 K + T)
To factor this in, the user can write the ΔT value to the
offset register. The ADT7476 then automatically adds it
to or subtracts it from the temperature measurement.
•
Some CPU manufacturers specify the high and low current
levels of the substrate transistors. The high current level of
the ADT7476, IHIGH, is 180 μA and the low level current,
ILOW, is 11 μA. If the ADT7476 current levels do not match
the current levels specified by the CPU manufacturer, it
might be necessary to remove an offset. The CPU’s data
sheet advises whether this offset needs to be removed and
how to calculate it. This offset can be programmed to the
offset register. It is important to note that, if more than one
offset must be considered, the algebraic sum of these
offsets must be programmed to the offset register.
If a discrete transistor is used with the ADT7476, the best
accuracy is obtained by choosing devices according to the
following criteria:
• Base-emitter voltage greater than 0.25 V at 11 μA, at
the highest operating temperature.
• Base-emitter voltage less than 0.95 V at 180 μA, at the lowest
operating temperature.
• Base resistance less than 100 Ω.
• Small variation in hFE (approximately 50 to 150) that indicates
tight control of VBE characteristics.
Transistors, such as 2N3904, 2N3906, or equivalents in SOT-23
packages, are suitable devices to use.
Table 10. Twos Complement Temperature Data Format
Temperature
–128°C
–50°C
–25°C
–10°C
0°C
10.25°C
25.5°C
50.75°C
75°C
100°C
125°C
127°C
1
Digital Output (10-Bit)1
1000 0000 00 (diode fault)
1100 1110 00
1110 0111 00
1111 0110 00
0000 0000 00
0000 1010 01
0001 1001 10
0011 0010 11
0100 1011 00
0110 0100 00
0111 1101 00
0111 1111 00
Bold numbers denote 2 LSBs of measurement in Extended Resolution
Register 2 (0x77) with 0.25°C resolution.
Table 11. Extended Range, Temperature Data Format
Temperature
–64°C
–1°C
0°C
1°C
10°C
25°C
50°C
75°C
100°C
125°C
191°C
1
Digital Output (10-Bit)1
0000 0000 00 (diode fault)
0011 1111 00
0100 0000 00
0100 0001 00
0100 1010 00
0101 1001 00
0111 0010 00
1000 1001 00
1010 0100 00
1011 1101 00
1111 1111 00
Bold numbers denote 2 LSBs of measurement in Extended Resolution
Register 2 (0x77) with 0.25°C resolution.
Nulling Out Temperature Errors
As CPUs run faster, it is more difficult to avoid high frequency
clocks when routing the D+/D– traces around a system board.
Even when recommended layout guidelines are followed, some
temperature errors can still be attributed to noise coupled onto
the D+/D– lines. Constant high frequency noise usually
attenuates, or increases, temperature measurements by a linear,
constant value.
The ADT7476 has temperature offset registers at Register 0x70
and Register 0x72 for the Remote 1 and Remote 2 temperature
channels. By doing a one-time calibration of the system, the
user can determine the offset caused by system board noise
and null it out using the offset registers. The offset registers
automatically add a twos complement 8-bit reading to every
temperature measurement.
Rev. A | Page 22 of 72
ADT7476
Changing Bit 1 of Configuration Register 5 (0x7C) changes the
resolution and therefore the range of the temperature offset as
either having a range of –63°C to +127°C with a resolution of
1°C or having a range of −63°C to +64°C with a resolution of
0.5°C. This temperature offset can be used to compensate for
linear temperature errors introduced by noise.
Register 0x4E, Remote 1 Temperature Low Limit = 0x81 default
Temperature Offset Registers
Register 0x52, Remote 2 Temperature Low Limit = 0x81 default
Register 0x70, Remote 1 Temperature Offset = 0x00 (0°C default)
Register 0x4F, Remote 1 Temperature High Limit = 0x7F default
Register 0x50, Local Temperature Low Limit = 0x81 default
Register 0x51, Local Temperature High Limit = 0x7F default
Register 0x53, Remote 2 Temperature High Limit = 0x7F default
Register 0x71, Local Temperature Offset = 0x00 (0°C default)
Reading Temperature from the ADT7476
Register 0x72, Remote 2 Temperature Offset = 0x00 (0°C default)
It is important to note that temperature can be read from the
ADT7476 as an 8-bit value (with 1°C resolution) or as a 10-bit
value (with 0.25°C resolution). If only 1°C resolution is required, the temperature readings can be read back at any time
and in no particular order.
ADT7463/ADT7476 Backwards Compatible Mode
By setting Bit 0 of Configuration Register 5 (0x7C), all temperature measurements are stored in the zone temperature value
registers (Register 0x25, Register 0x26, and Register 0x27) in
twos complement in the range −63°C to +127°C. The
temperature limits must be reprogrammed in twos
complement.
If a twos complement temperature below −63°C is entered, the
temperature is clamped to −63°C. In this mode, the diode fault
condition remains −128°C = 1000 0000, while in the extended
temperature range (−63°C to +191°C), the fault condition is
represented by −64°C = 0000 0000.
If the 10-bit measurement is required, this involves a 2-register
read for each measurement. The extended resolution register
(0x77) should be read first. This causes all temperature reading
registers to be frozen until all temperature reading registers
have been read from. This prevents an MSB reading from being
updated while its two LSBs are being read and vice versa.
ADDITIONAL ADC FUNCTIONS FOR
TEMPERATURE MEASUREMENT
A number of other functions are available on the ADT7476 to
offer the system designer increased flexibility.
Temperature Measurement Registers
Register 0x25, Remote 1 Temperature
Turn-Off Averaging
Register 0x26, Local Temperature
For each temperature measurement read from a value register,
16 readings have actually been made internally, and the results
averaged, before being placed into the value register. Sometimes
it is necessary to take a very fast measurement. Setting Bit 4 of
Configuration Register 2 (0x73) turns averaging off. The default
round-robin cycle time takes 146.5 ms.
Register 0x27, Remote 2 Temperature
Register 0x77, Extended Resolution 2 = 0x00 default
Bits [7:6] TDM2, Remote 2 temperature LSBs
Bits [5:4] LTMP, Local temperature LSBs
Table 12. Conversion Time with Averaging Disabled
Bits [3:2] TDM1, Remote 1 temperature LSBs
Temperature Measurement Limit Registers
Associated with each temperature measurement channel are high
and low limit registers. Exceeding the programmed high or low
limit causes the appropriate status bit to be set. Exceeding either
limit can also generate SMBALERT interrupts (depending on
the way the interrupt mask register is programmed and assuming
that SMBALERT is set as an output on the appropriate pin).
Channel
Voltage Channels
Remote Temperature 1
Remote Temperature 2
Local Temperature
Measurement Time (ms)
0.7
7
7
1.3
When Bit 7 of Configuration Register 6 (0x10) is set, the default
round-robin cycle time increases to 240 ms.
Table 13. Conversion Time with Averaging Enabled
Channel
Voltage Channels
Remote Temperature
Local Temperature
Rev. A | Page 23 of 72
Measurement Time (ms)
11
39
12
ADT7476
Single-Channel ADC Conversions
Setting Bit 6 of Configuration Register 2 (0x73) places the
ADT7476 into single-channel ADC conversion mode. In this
mode, the ADT7476 can be made to read a single temperature
channel only. The appropriate ADC channel is selected by
writing to Bits [7:5] of the TACH1 minimum high byte
register (0x55).
The fans run at this speed until the temperature drops below
THERM minus hysteresis. This can be disabled by setting the
boost bit in Configuration Register 3, Bit 2 (Register 0x78). The
hysteresis value for the THERM temperature limit is the value
programmed into the hysteresis registers (Register 0x6D and
Register 0x6E). The default hysteresis value is 4°C.
THERM LIMIT
Table 14. Programming Single-Channel ADC Mode for
Temperatures
HYSTERESIS (°C)
Channel Selected
Remote 1 temperature
Local temperature
Remote 2 temperature
TEMPERATURE
FANS
Configuration Register 2 (0x73)
100%
05382-029
Register 0x55, Bits [7:5]
101
110
111
Figure 28. THERM Temperature Limit Operation
Bit 4 = 1, averaging off.
TACH1 Minimum High Byte (0x55)
THERM can be disabled on specific temperature channels using
Bits [7:5] of Configuration Register 5 (0x7C). THERM can also
be disabled by:
Bits [7:5] selects ADC channel for single-channel convert mode.
•
In Offset 64 mode, writing −64°C to the appropriate
THERM temperature limit.
•
In twos complement mode, writing −128°C to the
appropriate THERM temperature limit.
Bit 6 = 1, single-channel convert mode.
Overtemperature Events
Overtemperature events on any of the temperature channels can
be detected and dealt with automatically in automatic fan speed
control mode. Register 0x6A to Register 0x6C are the THERM
temperature limits. When a temperature exceeds its THERM
temperature limit, all PWM outputs run at the maximum
PWM duty cycle (Register 0x38, Register 0x39, and Register
0x3A). This effectively runs the fans at the fastest allowed speed.
Rev. A | Page 24 of 72
ADT7476
LIMITS, STATUS REGISTERS, AND INTERRUPTS
LIMIT VALUES
16-Bit Limits
Associated with each measurement channel on the ADT7476
are high and low limits. These can form the basis of system
status monitoring. A status bit can be set for any out-of-limit
condition and is detected by polling the device. Alternatively,
SMBALERT interrupts can be generated to flag out-of-limit
conditions to a processor or microcontroller.
The fan TACH measurements are 16-bit results. The fan TACH
limits are also 16 bits, consisting of a high byte and low byte.
Because fans running under speed or stalled are normally the
only conditions of interest, only high limits exist for fan TACHs.
Because the fan TACH period is actually being measured,
exceeding the limit indicates a slow or stalled fan.
8-Bit Limits
Fan Limit Registers
The following is a list of 8-bit limits on the ADT7476.
Register 0x54, TACH1 Minimum Low Byte = 0xFF default
Voltage Limit Registers
Register 0x55, TACH1 Minimum High Byte = 0xFF default
Register 0x44, 2.5 V Low Limit = 0x00 default
Register 0x56, TACH2 Minimum Low Byte = 0xFF default
Register 0x45, 2.5 V High Limit = 0xFF default
Register 0x57, TACH2 Minimum High Byte = 0xFF default
Register 0x46, VCCP Low Limit = 0x00 default
Register 0x58, TACH3 Minimum Low Byte = 0xFF default
Register 0x47, VCCP High Limit = 0xFF default
Register 0x59, TACH3 Minimum High Byte = 0xFF default
Register 0x48, VCC Low Limit = 0x00 default
Register 0x5A, TACH4 Minimum Low Byte = 0xFF default
Register 0x49, VCC High Limit = 0xFF default
Register 0x5B, TACH4 Minimum High Byte = 0xFF default
Register 0x4A, 5 V Low Limit = 0x00 default
Out-of-Limit Comparisons
Once all limits have been programmed, the ADT7476 can be
enabled for monitoring. The ADT7476 measures all voltage and
temperature measurements in round-robin format and sets the
appropriate status bit for out-of-limit conditions. TACH measurements are not part of this round-robin cycle. Comparisons
are done differently depending on whether the measured value
is being compared to a high or low limit.
Register 0x4B, 5 V High Limit = 0xFF default
Register 0x4C, 12 V Low Limit = 0x00 default
Register 0x4D, 12 V High Limit = 0xFF default
Temperature Limit Registers
Register 0x4E, Remote 1 Temperature Low Limit = 0x81 default
High Limit > Comparison Performed
Register 0x4F, Remote 1 Temperature High Limit = 0x7F default
Low Limit ≤ Comparison Performed
Register 0x6A, Remote 1 THERM Limit = 0x64 default
Register 0x51, Local Temperature High Limit = 0x7F default
Voltage and temperature channels use a window comparator
for error detecting and, therefore, have high and low limits.
Fan speed measurements use only a low limit. This fan limit is
needed only in manual fan control mode.
Register 0x6B, Local THERM Limit = 0x64 default
Analog Monitoring Cycle Time
Register 0x50, Local Temperature Low Limit = 0x81 default
Register 0x52, Remote 2 Temperature Low Limit = 0x81 default
Register 0x53, Remote 2 Temperature High Limit = 0x7F default
Register 0x6C, Remote 2 THERM Limit = 0x64 default
THERM Limit Register
Register 0x7A, THERM Limit = 0x00 default
The analog monitoring cycle begins when a 1 is written to the
start bit (Bit 0) of Configuration Register 1 (0x40). The ADC
measures each analog input in turn, and, as each measurement
is completed, the result is automatically stored in the
appropriate value register. This round-robin monitoring
cycle continues unless disabled by writing a 0 to Bit 0 of
Configuration Register 1.
As the ADC is normally left to free-run in this manner, the
time taken to monitor all the analog inputs is normally not of
interest, because the most recently measured value of any input
can be read out at any time.
Rev. A | Page 25 of 72
ADT7476
For applications where the monitoring cycle time is important,
it can be calculated easily.
The total number of channels measured is
•
Four dedicated supply voltage inputs
•
Supply voltage (VCC pin)
•
Local temperature
Interrupt Status Register 1 (0x41)
Bit 7 (OOL) = 1, denotes a bit in Status Register 2 is set and
Status Register 2 should be read.
Bit 6 (R2T) = 1, Remote 2 temperature high or low limit has
been exceeded.
•
Two remote temperatures
As mentioned previously, the ADC performs round-robin
conversions and takes 11 ms for each voltage measurement,
12 ms for a local temperature reading, and 39 ms for each
remote temperature reading. The total monitoring cycle time
for averaged voltage and temperature monitoring is, therefore,
nominally
(5 × 11) + 12 + (2 × 39) = 145 ms
Fan TACH measurements are made in parallel and are not
synchronized with the analog measurements in any way.
Bit 5 (LT) = 1, Local temperature high or low limit has been
exceeded.
Bit 4 (R1T) = 1, Remote 1 temperature high or low limit has
been exceeded.
Bit 3 (5 V) = 1, 5 V high or low limit has been exceeded.
Bit 2 (VCC) = 1, VCC high or low limit has been exceeded.
Bit 1 (VCCP) = 1, VCCP high or low limit has been exceeded.
Bit 0 (2.5 V) = 1, 2.5 V high or low limit has been exceeded. If
the 2.5 V input is configured as THERM, this bit represents the
status of THERM.
STATUS REGISTERS
The results of limit comparisons are stored in Status Register 1
and Status Register 2. The status register bit for each channel
reflects the status of the last measurement and limit comparison
on that channel. If a measurement is within limits, the corresponding status register bit is cleared to 0. If the measurement
is out-of-limits, the corresponding status register bit is set to 1.
Interrupt Status Register 2 (0x42)
The state of the various measurement channels can be polled by
reading the status registers over the serial bus. In Bit 7 (OOL) of
Status Register 1 (0x41), 1 means an out-of-limit event has been
flagged in Status Register 2. This means the user also needs to
read Status Register 2. Alternatively, Pin 10 or Pin 14 can be
configured as an SMBALERT output. This hard interrupt
automatically notifies the system supervisor of an out-of-limit
condition. Reading the status registers clears the appropriate
status bit as long as the error condition that caused the interrupt
has cleared. Status register bits are sticky. Whenever a status bit
is set, indicating an out-of-limit condition, it remains set even
if the event that caused it has gone away (until read).
Bit 5 (F4P) = 1, indicates Fan 4 has dropped below minimum
speed. Alternatively, indicates that the THERM limit has been
exceeded, if the THERM function is used. Alternatively,
indicates the status of GPIO6.
The only way to clear the status bit is to read the status register
after the event has gone. Interrupt status mask registers
(Register 0x74 and Register 0x75) allow individual interrupt
sources to be masked from causing an SMBALERT. However, if
one of these masked interrupt sources goes out-of-limit, its
associated status bit is set in the interrupt status registers.
Bit 1 (OVT) = 1, indicates a THERM overtemperature limit has
been exceeded.
Bit 7 (D2 FAULT) = 1, indicates an open or short on D2+/D2–
inputs.
Bit 6 (D1 FAULT) = 1, indicates an open or short on D1+/D1–
inputs.
Bit 4 (FAN3) = 1, indicates Fan 3 has dropped below
minimum speed.
Bit 3 (FAN2) = 1, indicates Fan 2 has dropped below
minimum speed.
Bit 2 (FAN1) = 1, indicates Fan 1 has dropped below
minimum speed.
Bit 0 (12V/VC) = 1, indicates a 12 V high or low limit has been
exceeded. If the VID code change function is used, this bit indicates a change in VID code on the VID0 to VID5 inputs.
SMBALERT Interrupt Behavior
The ADT7476 can be polled for status, or an SMBALERT
interrupt can be generated for out-of-limit conditions. It is
important to note how the SMBALERT output and status
bits behave when writing interrupt handler software.
Rev. A | Page 26 of 72
ADT7476
HIGH LIMIT
HIGH LIMIT
TEMPERATURE
TEMPERATURE
CLEARED ON READ
(TEMP BELOW LIMIT)
CLEARED ON READ
(TEMP BELOW LIMIT)
STICKY
STATUS BIT
05382-030
TEMP BACK IN LIMIT
(STATUS BIT STAYS SET)
SMBALERT
Figure 29. SMBALERT and Status Bit Behavior
TEMP BACK IN LIMIT
(STATUS BIT STAYS SET)
SMBALERT
Figure 29 shows how the SMBALERT output and sticky status
bits behave. Once a limit is exceeded, the corresponding status
bit is set to 1. The status bit remains set until the error condition subsides and the status register is read. The status bits
are referred to as sticky, because they remain set until read
by software. This ensures that an out-of-limit event cannot
be missed, if software is polling the device periodically.
INTERRUPT
MASK BIT SET
INTERRUPT MASK BIT
CLEARED
(SMBALERT REARMED)
Figure 30. How Masking the Interrupt Source Affects SMBALERT Output
Interrupt Mask Register 1 (0x74)
Bit 7 (OOL) = 1, masks SMBALERT for any alert condition
flagged in Status Register 2.
Bit 6 (R2T) = 1, masks SMBALERT for Remote 2 temperature.
Note: The SMBALERT output remains low for the entire
duration that a reading is out-of-limit and until the status
register has been read. This has implications on how software handles the interrupt.
Bit 5 (LT) = 1, masks SMBALERT for local temperature.
Bit 4 (R1T) = 1, masks SMBALERT for Remote 1 temperature.
Handling SMBALERT Interrupts
Bit 3 (5 V) = 1, masks SMBALERT for 5 V channel.
To prevent the system from being tied up servicing interrupts,
it is recommend to handle the SMBALERT interrupt as follows:
Bit 2 (VCC) = 1, masks SMBALERT for VCC channel.
1.
Detect the SMBALERT assertion.
Bit 1 (VCCP) = 1, masks SMBALERT for VCCP channel.
2.
Enter the interrupt handler.
Bit 0 (2.5 V) = 1, masks SMBALERT for 2.5V/ THERM.
3.
Read the status registers to identify the interrupt source.
4.
Mask the interrupt source by setting the appropriate mask
bit in the interrupt mask registers (0x74 and 0x75).
5.
Take the appropriate action for a given interrupt source.
6.
Exit the interrupt handler.
7.
Periodically poll the status registers. If the interrupt status
bit has cleared, reset the corresponding interrupt mask bit
to 0. This causes the SMBALERT output and status bits to
behave as shown in Figure 30.
Interrupt Mask Register 2 (0x75)
Bit 7 (D2) = 1, masks SMBALERT for Diode 2 errors.
Bit 6 (D1) = 1, masks SMBALERT for Diode 1 errors.
Bit 5 (F4P) = 1, masks SMBALERT for Fan 4 failure.
Masking Interrupt Sources
Interrupt Mask Register 1 and Interrupt Mask Register 2 are
located at Register 0x74 and Register 0x75. These allow
individual interrupt sources to be masked out to prevent
SMBALERT interrupts. Note: Masking an interrupt source
prevents only the SMBALERT output from being asserted; the
appropriate status bit is set normally.
If the TACH4 pin is being used as the THERM input, this bit
masks SMBALERT for a THERM event. If the TACH4 pin is
being used as GPIO6, setting this bit masks interrupts related
to GPIO6.
Bit 4 (FAN3) = 1, masks SMBALERT for Fan 3.
Bit 3 (FAN2) = 1, masks SMBALERT for Fan 2.
Bit 2 (FAN1) = 1, masks SMBALERT for Fan 1.
Bit 1 (OVT) = 1, masks SMBALERT for overtemperature
(exceeding THERM temperature limits).
Bit 0 (12V/VC) = 1, masks SMBALERT for 12 V channel or
for a VID code change, depending on the function used.
Rev. A | Page 27 of 72
05382-031
STICKY
STATUS BIT
ADT7476
Enabling the SMBALERT Interrupt Output
If the temperature is below TMIN or if the duty cycle in manual
mode is set to Register 0x00, pulling the THERM low externally
has no effect. See Figure 31 for more information.
The SMBALERT interrupt function is disabled by default.
Pin 10 or Pin 14 can be reconfigured as an SMBALERT output to signal out-of-limit conditions.
TMIN
Table 15. Configuring Pin 10 as SMBALERT Output
Register
Configuration Register 3 (0x78)
Bit Setting
[1] Pin 10 = SMBALERT
[0] Pin 10 = PWM2
THERM
Assigning THERM Functionality to a Pin
Pin 14 on the ADT7476 has four possible functions:
SMBALERT, THERM, GPIO6, and TACH4. The user
chooses the required functionality by setting Bit 0 and Bit 1
of Configuration Register 4 (0x7D).
If THERM is enabled, Configuration Register 3 (0x78), Bit 1,
the following occurs:
•
Pin 22 becomes THERM.
•
If Pin 14 is configured as THERM (Bit 0 and Bit 1 of
Configuration Register 4 at Address 0x7D), THERM is
enabled on this pin.
Figure 31. Asserting THERM Low as an Input
in Automatic Fan Speed Control Mode
THERM TIMER
The ADT7476 has an internal timer to measure THERM
assertion time. For example, the THERM input can be
connected to the PROCHOT output of a Pentium 4 CPU
to measure system performance. The THERM input can also
be connected to the output of a trip point temperature sensor.
If THERM is not enabled, the following occurs:
•
Pin 22 becomes a 2.5 V measurement input.
•
If Pin 14 is configured as THERM, then THERM is
disabled on this pin.
Table 16. Configuring Pin 14
Bit 0
0
0
1
1
Bit 1
0
1
0
1
THERM ASSERTED TO LOW AS AN INPUT:
FANS DO NOT GO TO 100%, BECAUSE
TEMPERATURE IS ABOVE TMIN AND FANS
ARE ALREADY RUNNING.
05382-032
THERM ASSERTED TO LOW AS AN INPUT:
FANS DO NOT GO TO 100%, BECAUSE
TEMPERATURE IS BELOW TMIN.
The timer is started on the assertion of the ADT7476 THERM
input and stopped when THERM is de-asserted. The timer
counts THERM times cumulatively, that is, the timer resumes
counting on the next THERM assertion. The THERM timer
continues to accumulate THERM assertion times until the
timer is read (it is cleared on read), or until it reaches full scale.
If the counter reaches full scale, it stops at that reading until
cleared.
Function
TACH4
THERM
SMBALERT
GPIO6
THERM as an Input
When THERM is configured as an input, the user can time
assertions on the THERM pin. This can be useful for connecting to the PROCHOT output of a CPU to gauge system
performance.
The 8-bit THERM timer register (0x79) is designed so Bit 0 is
set to 1 on the first THERM assertion. Once the cumulative
THERM assertion time has exceeded 45.52 ms, Bit 1 of the
THERM timer is set and Bit 0 now becomes the LSB of the
timer with a resolution of 22.76 ms (see Figure 32).
The user can also set up the ADT7476 so that, when the
THERM pin is driven low externally, the fans run at 100%. The
fans run at 100% for the duration of the time that the THERM
pin is pulled low. This is done by setting the BOOST bit (Bit 2)
in Configuration Register 3 (0x78) to 1. This works only if the
fan is already running, for example, in manual mode when the
current duty cycle is above Register 0x00, or in automatic mode
when the temperature is above TMIN.
Rev. A | Page 28 of 72
ADT7476
The THERM timer increments from zero.
THERM
3.
0 0 0 0 0 0 0 1
7 6 5 4 3 2 1 0
THERM ASSERTED
≤ 22.76ms
Generating SMBALERT Interrupts from THERM Timer
Events
THERM
The ADT7476 can generate SMBALERTs when a programmable THERM timer limit has been exceeded. This allows the
system designer to ignore brief, infrequent THERM assertions,
while capturing longer THERM timer events. Register 0x7A is
the THERM timer limit register. This 8-bit register allows a
limit from 0 seconds (first THERM assertion) to 5.825 seconds
to be set before an SMBALERT is generated. The THERM timer
value is compared with the contents of the THERM timer limit
register. If the THERM timer value exceeds the THERM timer
limit value, then the F4P bit (Bit 5) of Status Register 2 is set and
an SMBALERT is generated.
ACCUMULATE THERM LOW
ASSERTION TIMES
THERM
TIMER
(REG. 0x79)
0 0 0 0 0 0 1 0
7 6 5 4 3 2 1 0
THERM ASSERTED
≥ 45.52ms
THERM
THERM
TIMER
(REG. 0x79)
0 0 0 0 0 1 0 1
7 6 5 4 3 2 1 0 THERM ASSERTED ≥ 113.8ms
(91.04ms + 22.76ms)
05382-033
ACCUMULATE THERM LOW
ASSERTION TIMES
Note: Depending on which pins are configured as a THERM
timer, setting the F4P bit (Bit 5) of Interrupt Mask Register 2
(0x75) or Bit 0 of Interrupt Mask Register 1 (0x74), masks out
SMBALERT; although the F4P bit of Interrupt Status Register 2 is
still set if the THERM timer limit is exceeded.
Figure 32. Understanding the THERM Timer
When using the THERM timer, be aware of the following.
After a THERM timer read (Register 0x79):
1.
The contents of the timer are cleared on read.
2.
The F4P bit (Bit 5) of Status Register 2 needs to be
cleared (assuming that the THERM timer limit has
been exceeded).
Figure 33 is a functional block diagram of the THERM timer,
limit, and associated circuitry. Writing a value of 0x00 to the
THERM timer limit register (Reg. 0x7A) causes an SMBALERT
to be generated on the first THERM assertion. A THERM timer
limit value of 0x01 generates an SMBALERT, once cumulative
THERM assertions exceed 45.52 ms.
If the THERM timer is read during a THERM assertion, the
following happens:
1.
The contents of the timer are cleared.
2.
Bit 0 of the THERM timer is set to 1, because a THERM
assertion is occurring.
2.914s
1.457s
728.32ms
THERM LIMIT
364.16ms
(REGISTER 0x7A) 182.08ms
91.04ms
45.52ms
22.76ms
2.914s
1.457s
728.32ms
364.16ms THERM TIMER
182.08ms (REGISTER 0x79)
91.04ms
45.52ms
22.76ms
0 1 2 3 4 5 6 7
7 6 5 4 3 2 1 0
THERM
THERM TIMER CLEARED ON READ
COMPARATOR
IN
OUT
F4P BIT (BIT 5)
STATUS REGISTER 2
SMBALERT
LATCH
RESET
CLEARED
ON READ
1 = MASK
F4P BIT (BIT 5)
MASK REGISTER 2
(REGISTER 0x75)
Figure 33. Functional Block Diagram of THERM Monitoring Circuitry
Rev. A | Page 29 of 72
05382-034
THERM
TIMER
(REG. 0x79)
If the THERM timer limit (Reg. 0x7A) = 0x00, the F4P bit
is set.
ADT7476
Configuring the Relevant THERM Behavior
Configure the desired pin as the THERM timer input.
Setting Bit 1 (THERM timer enable) of Configuration
Register 3 (0x78) enables the THERM timer monitoring
functionality. This is disabled on Pin 14 and Pin 22 by
default.
Setting Bit 0 and Bit 1 (PIN14FUNC) of Configuration
Register 4 (0x7D) enables THERM timer output
functionality on Pin 22 (Bit 1 of Configuration Register 3,
THERM, must also be set). Pin 14 can also be used as
TACH4.
2.
Select the desired fan behavior for THERM timer events.
Assuming the fans are running, setting Bit 2 (BOOST bit)
of Configuration Register 3 (0x78) causes all fans to run at
100% duty cycle whenever THERM is asserted. This allows
fail-safe system cooling. If this bit is 0, the fans run at their
current settings and are not affected by THERM events. If
the fans are not already running when THERM is asserted,
the fans do not run to full speed.
3.
Select whether THERM timer events should generate
SMBALERT interrupts.
When set, Bit 5 (F4P) of Interrupt Mask Register 2 (0x75)
or Bit 0 of Interrupt Mask Register 1 (0x74), depending on
which pins are configured as a THERM timer, masks out
the SMBALERT when the THERM timer limit value is
exceeded. This bit should be cleared if the SMBALERT
based on THERM events are required.
4.
Select a suitable THERM limit value.
This value determines whether an SMBALERT is generated on the first THERM assertion, or only if a cumulative
THERM assertion time limit is exceeded. A value of 0x00
causes an SMBALERT to be generated on the first THERM
assertion.
5.
Configuring the THERM Pin as an Output
In addition to monitoring THERM as an input, the ADT7476 can
optionally drive THERM low as an output. When PROCHOT is
bidirectional, THERM can be used to throttle the processor by
asserting PROCHOT. The user can preprogram system-critical
thermal limits. If the temperature exceeds a thermal limit by
0.25°C, THERM asserts low. If the temperature is still above the
thermal limit on the next monitoring cycle, THERM stays low.
THERM remains asserted low until the temperature is equal to
or below the thermal limit. Because the temperature for that
channel is measured only once for every monitoring cycle, after
THERM asserts it is guaranteed to remain low for at least one
monitoring cycle.
The THERM pin can be configured to assert low, if the
Remote 1, local, or Remote 2 THERM temperature limits are
exceeded by 0.25°C. The THERM temperature limit registers
are at Register 0x6A, Register 0x6B, and Register 0x6C,
respectively. Setting Bits [7:5] of Configuration Register 5 (0x7C)
enables the THERM output feature for the Remote 1, local, and
Remote 2 temperature channels, respectively. Figure 34 shows
how the THERM pin asserts low as an output in the event of a
critical overtemperature.
THERM LIMIT
0.25°C
THERM LIMIT
TEMP
Select a THERM monitoring time.
This value specifies how often OS- or BIOS-level software
checks the THERM timer. For example, BIOS can read the
THERM timer once an hour to determine the cumulative
THERM assertion time. If, for example, the total THERM
assertion time is <22.76 ms in Hour 1, >182.08 ms in Hour
2, and >5.825 sec in Hour 3, this indicates that system performance is degrading significantly, because THERM is
asserting more frequently on an hourly basis.
THERM
MONITORING
CYCLE
05382-035
1.
Alternatively, OS- or BIOS-level software can timestamp
when the system is powered on. If an SMBALERT is generated due to the THERM timer limit being exceeded,
another timestamp can be taken. The difference in time
can be calculated for a fixed THERM timer limit time.
For example, if it takes one week for a THERM timer limit
of 2.914 seconds to be exceeded, and the next time it takes
only 1 hour, this is an indication of a serious degradation in
system performance.
Figure 34. Asserting THERM as an Output, Based on Tripping THERM Limits
An alternative method of disabling THERM is to program the
THERM temperature limit to –63°C or less in Offset 64 mode,
or −128°C or less in twos complement mode; that is, for
THERM temperature limit values less than −63°C or −128°C,
respectively, THERM is disabled.
Rev. A | Page 30 of 72
ADT7476
Enabling and Disabling THERM on individual Channels
THERM can be enabled/disabled for individual or combinations of temperature channels using Bits [7:5] of Configuration
Register 5 (0x7C).
THERM Hysteresis
Setting Bit 0 of Configuration Register 7 (0x11) disables
THERM hysteresis.
If THERM hysteresis is enabled and THERM is disabled (Bit 2
of Configuration Register 4, 0x7D), the THERM pin does not
assert low when a THERM event occurs. If THERM hysteresis
is disabled and THERM is disabled (Bit 2 of Configuration
Register 4, 0x7D) and assuming the appropriate pin is configured as THERM), the THERM pin asserts low when a THERM
event occurs.
Typical notebook fans draw a nominal 170 mA, so SOT devices
can be used where board space is a concern. In desktops, fans
typically draw 250 mA to 300 mA each. If you drive several fans
in parallel from a single PWM output or drive larger server
fans, the MOSFET must handle the higher current requirements. The only other stipulation is that the MOSFET should
have a gate voltage drive, VGS < 3.3 V, for direct interfacing to
the PWM output pin. The MOSFET should also have a low on
resistance to ensure that there is not a significant voltage drop
across the FET, which would reduce the voltage applied across
the fan and, therefore, the maximum operating speed of the fan.
Figure 35 shows how to drive a 3-wire fan using PWM control.
12V
12V
10kΩ
TACH
10kΩ
4.7kΩ
If THERM and THERM hysteresis are both enabled, the
THERM output asserts as expected.
ADT7476
12V
FAN
TACH
1N4148
3.3V
10kΩ
Q1
NDT3055L
PWM
In manual mode, THERM events do not cause fans to go to full
speed, unless Bit 3 of Configuration Register 6 (0x10) is set to 1.
Bit 2 in Configuration Register 4 (0x7D) can be set to disable
THERM events from affecting the fans.
FAN DRIVE USING PWM CONTROL
The ADT7476 uses pulse-width modulation (PWM) to control
fan speed. This relies on varying the duty cycle (or on/off ratio)
of a square wave applied to the fan to vary the fan speed. The
external circuitry required to drive a fan using PWM control is
extremely simple. For 4-wire fans, the PWM drive might need
only a pull-up resistor. In many cases, the 4-wire fan PWM
input has a built-in, pull-up resistor.
The ADT7476 PWM frequency can be set to a selection of
low frequencies or a single high PWM frequency. The low
frequency options are used for 3-wire fans, while the high
frequency option is usually used with 4-wire fans.
Figure 35. Driving a 3-Wire Fan Using an N-Channel MOSFET
Figure 35 uses a 10 kΩ pull-up resistor for the TACH signal.
This assumes that the TACH signal is an open-collector from
the fan. In all cases, the TACH signal from the fan must be kept
below 3.6 V maximum to prevent damaging the ADT7476.
Figure 36 shows a fan drive circuit using an NPN transistor
such as a general-purpose MMBT2222. While these devices
are inexpensive, they tend to have much lower current handling capabilities and higher on resistance than MOSFETs.
When choosing a transistor, care should be taken to ensure
that it meets the fan’s current requirements. Ensure that the
base resistor is chosen, so the transistor is saturated when the
fan is powered on.
Because in 4-wire fans the fan drive circuitry is not switched on
or off, as with previous PWM driven/powered fans, the internal
drive circuit is always on and uses the PWM input as a signal
instead of a power supply. This enables the internal fan drive
circuit to perform better than 3-wire fans, especially for high
frequency applications.
12V
For 3-wire fans, a single N-channel MOSFET is the only drive
device required. The specifications of the MOSFET depend on
the maximum current required by the fan being driven and
the input capacitance of the FET. Because a 10 kΩ (or greater)
resistor must be used as a PWM pull-up, an FET with large
input capacitance can cause the PWM output to become
distorted and adversely affect the fan control range. This is a
requirement only when using high frequency PWM mode.
12V
10kΩ
TACH
10kΩ
4.7kΩ
ADT7476
TACH
12V
FAN
1N4148
3.3V
470Ω
PWM
Q1
MMBT2222
Figure 36. Driving a 3-Wire Fan Using an NPN Transistor
Rev. A | Page 31 of 72
05382-037
Additionally, Bit 3 of Configuration Register 4 (0x7D) can be
used to select PWM speed on THERM event (100% or
maximum PWM).
05382-036
THERM Operation in Manual Mode
ADT7476
Figure 37 shows a typical drive circuit for 4-wire fans.
Because the MOSFET can handle up to 3.5 A, it is simply a
matter of connecting another fan directly in parallel with the
first. Care should be taken in designing drive circuits with
transistors and FETs to ensure the PWM outputs are not
required to source current, and they sink less than the
5 mA maximum current specified on the data sheet.
12V 12V
12V, 4-WIRE FAN
10kΩ
10kΩ
4.7kΩ
TACH
PWM
3.3V
Driving up to Three Fans from PWM3
2kΩ
TACH measurements for fans are synchronized to particular
PWM channels; for example, TACH1 is synchronized to
PWM1. TACH3 and TACH4 are both synchronized to PWM3,
so PWM3 can drive two fans. Alternatively, PWM3 can be programmed to synchronize TACH2, TACH3, and TACH4 to the
PWM3 output. This allows PWM3 to drive two or three fans.
In this case, the drive circuitry looks the same, as shown in
Figure 38 and Figure 39. The SYNC bit in Register 0x62 enables
this function.
05382-038
PWM
3.3V
Figure 37. Driving a 4-Wire Fan
Driving Two Fans from PWM3
The ADT7476 has four TACH inputs available for fan speed
measurement, but only three PWM drive outputs. If a fourth
fan is being used in the system, it should be driven from the
PWM3 output in parallel with the third fan.
Synchronization is not required in high frequency mode when
used with 4-wire fans.
Figure 38 shows how to drive two fans in parallel using low
cost NPN transistors. Figure 39 shows the equivalent circuit
using a MOSFET.
Enhance Acoustics Register 1 (0x62)
Bit 4 SYNC = 1, synchronizes TACH2, TACH3, and TACH4
to PWM3.
12V
ADT7476
3.3V
3.3V
TACH3
1kΩ
PWM3
3.3V
Q1
MMBT3904
2.2kΩ
10Ω
TACH4
3.3V
Q2
MMBT2222
05382-039
10Ω
Q3
MMBT2222
Figure 38. Interfacing Two Fans in Parallel to the PWM3 Output Using Low Cost NPN Transistors
3.3V
10kΩ
TYPICAL
TACH4
3.3V
ADT7476
+V
3.3V
+V
10kΩ
TYPICAL
TACH
TACH3
3.3V
3.3V
5V OR
12V FAN
1N4148
TACH
5V OR
12V FAN
10kΩ
TYPICAL
PWM3
Q1
NDT3055L
05382-040
ADT7476
TACH
VCC
1N4148
TACH
Figure 39. Interfacing Two Fans in Parallel to the PWM3 Output Using a Single N-Channel MOSFET
Rev. A | Page 32 of 72
ADT7476
VCC
Figure 40 shows how to lay out a common circuit arrangement
for 3-wire fans.
PULL-UP
4.7kΩ
TYPICAL
TACH
OUTPUT
TACH
12V OR 5V
ZD1*
R1
1N4148
Figure 42. Fan with TACH Pull-Up to Voltage > 3.6 V (for Example, 12 V),
Clamped with Zener Diode
R4
PWM
Q1
MMBT2222
R3
If the fan has a strong pull-up (less than 1 kΩ) to 12 V or a
totem-pole output, a series resistor can be added to limit the
Zener current, as shown in Figure 43.
05382-041
TACH
ADT7476
*CHOOSE ZD1 VOLTAGE APPROXIMATELY 0.8 × VCC
3.3V OR 5V
R2
FAN SPEED
COUNTER
05382-043
12V
LAYING OUT 3-WIRE FANS
Figure 40. Planning for 3-Wire Fans on a PCB
VCC
5V OR 12V
TACH Inputs
FAN
Signal conditioning in the ADT7476 accommodates the slow
rise and fall times typical of fan tachometer outputs. The maximum input signal range is 0 V to 3.6 V, even though VCC is
3.3 V. In the event that these inputs are supplied from fan
outputs that exceed 0 V to 3.6 V, either resistive attenuation
of the fan signal or diode clamping must be included to keep
inputs within an acceptable range.
R1
10kΩ
TACH
OUTPUT
TACH
ZD1
ZENER*
If the fan TACH output has a resistive pull-up to VCC, it can be
connected directly to the fan input, as shown in Figure 41.
*CHOOSE ZD1 VOLTAGE APPROXIMATELY 0.8 × VCC
Figure 43. Fan with Strong TACH Pull-Up to > VCC or Totem-Pole Output,
Clamped with Zener Diode and Resistor
Alternatively, a resistive attenuator can be used, as shown
in Figure 44. R1 and R2 should be chosen such that
The fan inputs have an input resistance of nominally 160 kΩ to
ground, which should be taken into account when calculating
resistor values.
VCC
12V
FAN SPEED
COUNTER
<1kΩ
Figure 41. Fan with TACH Pull-Up to VCC
R1*
TACH
OUTPUT
If the fan output has a resistive pull-up to 12 V, or other voltage
greater than 3.6 V, the fan output can be clamped with a Zener
diode, as shown in Figure 42. The Zener diode voltage should
be chosen so that it is greater than VIH of the TACH input but
less than 3.6 V, allowing for the voltage tolerance of the Zener. A
value of between 3 V and 3.6 V is suitable.
TACH
R2*
*SEE TEXT
FAN SPEED
COUNTER
ADT7476
05382-045
ADT7476
05382-042
TACH
ADT7476
With a pull-up voltage of 12 V and pull-up resistor less than
1 kΩ, suitable values for R1 and R2 are 100 kΩ and 40 kΩ,
respectively. This gives a high input voltage of 3.42 V.
VCC
12V
TACH
OUTPUT
FAN SPEED
COUNTER
2 V < VPULL-UP × R2/(RPULL-UP + R1 + R2) < 3.6 V
Figure 41 to Figure 44 show circuits for most common fan
TACH outputs.
PULL-UP
4.7kΩ
TYP
PULL-UP TYP
<1kΩ OR
TOTEM POLE
05382-044
Pin 9, Pin 11, Pin 12, and Pin 14 (when configured as TACH
inputs) are high impedance inputs intended for fan speed
measurement.
Figure 44. Fan with Strong TACH Pull-Up to > VCC or Totem-Pole Output,
Attenuated with R1/R2
Rev. A | Page 33 of 72
ADT7476
The fan counter does not count the fan TACH output pulses
directly, because the fan speed could be less than 1000 RPM and
it takes several seconds to accumulate a reasonably large and
accurate count. Instead, the period of the fan revolution is
measured by gating an on-chip 90 kHz oscillator into the input
of a 16-bit counter for N periods of the fan TACH output
(Figure 45), so the accumulated count is actually proportional
to the fan tachometer period and inversely proportional to the
fan speed.
N, the number of pulses counted, is determined by the settings
of TACH pulses per revolution register (0x7B). This register
contains two bits for each fan, allowing one, two (default), three,
or four TACH pulses to be counted.
CLOCK
Because the device is essentially measuring the fan TACH
period, the higher the count value, the slower the fan is actually running. A 16-bit fan tachometer reading of 0xFFFF
indicates that either the fan has stalled or is running very
slowly (<100 RPM).
High Limit > Comparison Performed
Because the actual fan TACH period is being measured, falling
below a fan TACH limit by 1 sets the appropriate status bit and
can be used to generate an SMBALERT.
Measuring fan TACH has the following caveat: When the
ADT7476 starts up, TACH measurements are locked. In effect,
an internal read of the low byte has been made for each TACH
input. The net result of this is that all TACH readings are
locked until the high byte is read from the corresponding
TACH registers. All TACH-related interrupts are also ignored
until the appropriate high byte is read.
PWM
TACH
Once the corresponding high byte has been read, TACH
measurements are unlocked and interrupts are processed as
normal.
1
05382-046
2
3
4
Figure 45. Fan Speed Measurement
Fan TACH Limit Registers
The fan TACH limit registers are 16-bit values consisting of
two bytes.
Fan Speed Measurement Registers
Register 0x54, TACH1 Minimum Low Byte = 0xFF default
The fan tachometer readings are 16-bit values consisting of a
2-byte read from the ADT7476.
Register 0x55, TACH1 Minimum High Byte = 0xFF default
Register 0x56, TACH2 Minimum Low Byte = 0xFF default
Register 0x28, TACH1 Low Byte = 0x00 default
Register 0x57, TACH2 Minimum High Byte = 0xFF default
Register 0x29, TACH1 High Byte = 0x00 default
Register 0x58, TACH3 Minimum Low Byte = 0xFF default
Register 0x2A, TACH2 Low Byte = 0x00 default
Register 0x59, TACH3 Minimum High Byte = 0xFF default
Register 0x2B, TACH2 High Byte = 0x00 default
Register 0x5A, TACH4 Minimum Low Byte = 0xFF default
Register 0x2C, TACH3 Low Byte = 0x00 default
Register 0x5B, TACH4 Minimum High Byte = 0xFF default
Register 0x2D, TACH3 High Byte = 0x00 default
Fan Speed Measurement Rate
Register 0x2E, TACH4 Low Byte = 0x00 default
The fan TACH readings are normally updated once
every second.
Register 0x2F, TACH4 High Byte = 0x00 default
Reading Fan Speed from the ADT7476
The measurement of fan speeds involves a 2-register read
for each measurement. The low byte should be read first.
This causes the high byte to be frozen until both high and
low byte registers have been read, preventing erroneous
TACH readings. The fan tachometer reading registers report
back the number of 11.11 μs period clocks (90 kHz oscillator)
gated to the fan speed counter, from the rising edge of the first
fan TACH pulse to the rising edge of the third fan TACH pulse
(assuming two pulses per revolution are being counted).
The FAST bit (Bit 3) of Configuration Register 3 (0x78), when
set, updates the fan TACH readings every 250 ms.
DC Bits
If any of the fans are not being driven by a PWM channel but
are powered directly from 5 V or 12 V, their associated dc bit
in Configuration Register 3 should be set. This allows TACH
readings to be taken on a continuous basis for fans connected
directly to a dc source. For 4-wire fans, once high frequency
mode is enabled, the dc bits do not need to be set as this is
automatically done internally.
Rev. A | Page 34 of 72
ADT7476
Calculating Fan Speed
Assuming a fan with two pulses per revolution, and with the
ADT7476 programmed to measure two pulses per revolution,
fan speed is calculated by
Fan Speed (RPM) = (90,000 × 60)/Fan TACH Reading
where Fan TACH Reading is the 16-bit fan tachometer reading.
Example
TACH1 High Byte Register (0x29) = 0x17
overcome inertia. The ADT7476 runs the fans just fast enough
to overcome inertia and is quieter on spin-up than fans
programmed to spin up for a given spin-up time.
Fan Startup Timeout
To prevent the generation of false interrupts as a fan spins up,
because it is below running speed, the ADT7476 includes a fan
startup timeout function. During this time, the ADT7476 looks
for two TACH pulses. If two TACH pulses are not detected,
then an interrupt is generated.
Fan startup timeout can be disabled by setting Bit 5 (FSPDIS) of
Configuration Register 1 (0x40).
TACH1 Low Byte Register (0x28) = 0xFF
PWM1, PWM2, PWM3 Configuration Registers
(0x5C, 0x5D, and 0x5E)
What is Fan 1 speed in RPM?
Fan 1 TACH Reading = 0x17FF = 6143 (decimal)
Bits [2:0] SPIN, startup timeout for PWM1 = 0x5C, PWM2 =
0x5D, and PWM3 = 0x5E.
RPM = (f × 60)/Fan 1 TACH Reading
000 = No startup timeout
RPM = (90,000 × 60)/6143
001 = 100 ms
Fan Speed = 879 RPM
010 = 250 ms default
Fan Pulses per Revolution
011 = 400 ms
Different fan models can output either one, two, three, or four
TACH pulses per revolution. Once the number of fan TACH
pulses is determined, it can be programmed into the fan pulses
per revolution register (0x7B) for each fan. Alternatively,
this register can be used to determine the number or pulses
per revolution output by a given fan. By plotting fan speed
measurements at 100% speed with different pulses per
revolution setting, the smoothest graph with the lowest
ripple determines the correct pulses per revolution value.
100 = 667 ms
Fan Pulses per Revolution Register
Bits [1:0] Fan 1 default = 2 pulses per revolution.
Bits [3:2] Fan 2 default = 2 pulses per revolution.
101 = 1 second
110 = 2 second
111 = 4 second
Disabling Fan Startup Timeout
Although fan startup makes fan spin-ups much quieter than
fixed-time spin-ups, the option exists to use fixed spin-up
times. Setting Bit 5 (FSPDIS) to 1 in Configuration Register 1
(0x40) disables the spin-up for two TACH pulses. Instead, the
fan spins up for the fixed time as selected in Register 0x5C to
Register 0x5E.
PWM Logic State
Bits [5:4] Fan 3 default = 2 pulses per revolution.
The PWM outputs can be programmed high for 100% duty
cycle (noninverted) or low for 100% duty cycle (inverted).
Bits [7:6] Fan 4 default = 2 pulses per revolution.
PWM1 Configuration Register (0x5C)
00 = 1 pulse per revolution.
10 = 3 pulses per revolution.
Bit 4 INV.
0 = Logic high for 100% PWM duty cycle.
1 = Logic low for 100% PWM duty cycle.
11 = 4 pulses per revolution.
PWM2 Configuration Register (0x5D)
01 = 2 pulses per revolution.
Fan Spin-Up
The ADT7476 has a unique fan spin-up function. It spins the
fan at 100% PWM duty cycle until two TACH pulses are detected on the TACH input. Once two TACH pulses have been
detected, the PWM duty cycle goes to the expected running
value, for example, 33%. The advantage is that fans have
different spin-up characteristics and take different times to
Bit 4 INV.
0 = Logic high for 100% PWM duty cycle.
1 = Logic low for 100% PWM duty cycle.
PWM3 Configuration Register (0x5E)
Bit 4 INV.
0 = Logic high for 100% PWM duty cycle.
1 = Logic low for 100% PWM duty cycle.
Rev. A | Page 35 of 72
ADT7476
Low Frequency Mode PWM Drive Frequency
The PWM drive frequency can be adjusted for the application.
Register 0x5F to Register 0x61 configure the PWM frequency
for PWM1 to PWM3, respectively.
PWM1, PWM 2, PWM3 Frequency Registers
(Register 0x5F to Register 0x61)
Once under manual control, each PWM output can be manually updated by writing Register 0x30 to Register 0x32 (PWMx
current duty cycle registers).
Programming the PWM Current Duty Cycle Registers
The PWM current duty cycle registers are 8-bit registers that
allow the PWM duty cycle for each output to be set anywhere
from 0% to 100% in steps of 0.39%. The value to be programmed
into the PWMMIN register is given by
Bits [2:0] FREQ
000 = 11.0 Hz
001 = 14.7 Hz
Value (decimal) = PWMMIN/0.39
010 = 22.1 Hz
Example 1: For a PWM duty cycle of 50%
011 = 29.4 Hz
Value (decimal) = 50/0.39 = 128 (decimal)
Value = 128 (decimal) or 0x80 (hex)
100 = 35.3 Hz default
101 = 44.1 Hz
Example 2: For a PWM duty cycle of 33%
110 = 58.8 Hz
Value (decimal) = 33/0.39 = 85 (decimal)
Value = 85 (decimal) or 0x54 (hex)
111 = 88.2 Hz
High Frequency Mode PWM Drive
Setting Bit 3 of Register 0x5F, Register 0x60, and Register 0x61
enables high frequency mode for Fan 1, Fan 2, and Fan 3
respectively.
In high frequency mode, the PWM drive frequency is always
22.5 kHz. When high frequency mode is enabled, the dc bits are
automatically asserted internally and do not need to be
changed.
Fan Speed Control
The ADT7476 controls fan speed using automatic and manual
modes.
In automatic fan speed control mode, fan speed is automatically
varied with temperature and without CPU intervention, once
initial parameters are set up. The advantage is that, if the system
hangs, the user is guaranteed that the system is protected from
overheating.
PWM Duty Cycle Registers
Register 0x30, PWM1 Duty Cycle = 0xFF (100% default)
Register 0x31, PWM2 Duty Cycle = 0xFF (100% default)
Register 0x32, PWM3 Duty Cycle = 0xFF (100% default)
By reading the PWMx current duty cycle registers, the user can
keep track of the current duty cycle on each PWM output, even
when the fans are running in automatic fan speed control mode
or acoustic enhancement mode.
PROGRAMMING TRANGE
TRANGE defines the distance between TMIN and 100% PWM.
For the ADT7467, ADT7468, and ADT7473, TRANGE is
effectively a slope. For the ADT7475 andADT7476, TRANGE is no
longer a slope but defines the temperature region where the
PWM output linearly ramps from PWMMIN to 100% PWM.
PWM = 100%
PWMMAX
PWMMIN
PWM Configuration Registers (0x5C to 0x5E)
TRANGE
Bits [7:5] BHVR
PWM = 0%
111 = manual mode
TMIN
Figure 46. TRANGE
Rev. A | Page 36 of 72
05382-047
In manual fan speed control mode, the ADT7476 allows the
duty cycle of any PWM output to be manually adjusted. This
can be useful, if the user wants to change fan speed in software
or adjust PWM duty cycle output for test purposes. Bits [7:5] of
Register 0x5C to Register 0x5E (PWM Configuration) control
the behavior of each PWM output.
ADT7476
PROGRAMMING THE AUTOMATIC FAN SPEED CONTROL LOOP
To understand the automatic fan speed control loop, use the
ADT7476 evaluation board and software while reading this
section.
This section provides the system designer with an understanding
of the automatic fan control loop, and provides step-by-step
guidance on effectively evaluating and selecting critical system
parameters. To optimize the system characteristics, the designer
needs to give some thought to system configuration, including
the number of fans, where they are located, and what temperatures are being measured in the particular system.
The mechanical or thermal engineer who is tasked with the
system thermal characterization should also be involved at
the beginning of the system development process.
MANUAL FAN CONTROL OVERVIEW
In unusual circumstances, it can be necessary to manually
control the speed of the fans. Because the ADT7476 has an
SMBus interface, a system can read back all necessary voltage,
fan speed, and temperature information, and use this
information to control the speed of the fans by writing to the
current PWM duty cycle registers (0x30, 0x31, and 0x32) of the
appropriate fan. Bits [7:5] of the PWMx configuration registers
(0x5C, 0x5D, 0x5E) are used to set up fans for manual control.
THERM OPERATION IN MANUAL MODE
In manual mode, if the temperature increases above the programmed THERM temperature limit, the fans automatically
speed up to maximum PWM or100% PWM, whichever way
the appropriate fan channel is configured.
AUTOMATIC FAN CONTROL OVERVIEW
Automatic fan speed control reduces acoustic noise by
optimizing fan speed according to accurately measured
temperature. Reducing fan speed can also decrease system
current consumption. The automatic fan speed control mode
is very flexible owing to the number of programmable parameters, including TMIN and TRANGE. The TMIN and TRANGE values for a
temperature channel and, therefore, for a given fan are critical,
because they define the thermal characteristics of the system.
The thermal validation of the system is one of the most important
steps in the design process, so these values should be selected
carefully.
Figure 47 gives a top-level overview of the automatic fan control
circuitry on the ADT7476. From a systems-level perspective,
up to three system temperatures can be monitored and used to
control three PWM outputs. The three PWM outputs can be
used to control up to four fans. The ADT7476 allows the speed
of four fans to be monitored. Each temperature channel has a
thermal calibration block, allowing the designer to individually
configure the thermal characteristics of each temperature
channel. For example, one can decide to run the CPU fan when
CPU temperature increases above 60°C and a chassis fan when
the local temperature increases above 45°C.
At this stage, the designer has not assigned these thermal
calibration settings to a particular fan drive (PWM) channel.
The right side of Figure 47 shows controls that are fan-specific.
The designer has individual control over parameters such as
minimum PWM duty cycle, fan speed failure thresholds, and
even ramp control of the PWM outputs. Automatic fan control,
then, ultimately allows graceful fan speed changes that are less
perceptible to the system user.
The ADT7476 can automatically control the speed of fans based
on the measured temperature. This is done independently of
CPU intervention once initial parameters are set up.
The ADT7476 has a local temperature sensor and two remote
temperature channels that can be connected to a CPU on-chip
thermal diode (available on Intel Pentium class CPUs and other
CPUs). These three temperature channels can be used as the
basis for automatic fan speed control to drive fans using PWM.
Rev. A | Page 37 of 72
ADT7476
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 1
TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
MUX
TMIN
LOCAL
TEMP
TRANGE
THERMAL CALIBRATION
100%
PWM
CONFIG
PWM
GENERATOR
REMOTE 2
TEMP
TMIN
TRANGE
TACHOMETER 3
AND 4
MEASUREMENT
0%
PWM1
TACH1
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 2
MEASUREMENT
0%
PWM
MIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM3
TACH3
05382-048
THERMAL CALIBRATION
Figure 47. Automatic Fan Control Block Diagram
STEP 1: HARDWARE CONFIGURATION
During system design, the motherboard sensing and control
capabilities should be addressed early in the design stages.
Decisions about how these capabilities are used should involve
the system thermal/mechanical engineer. Ask the following
questions:
•
What ADT7476 functionality is used?
•
PWM2 or SMBALERT?
•
TACH4 fan speed measurement or overtemperature
THERM function?
•
2.5 V voltage monitoring or overtemperature THERM
function?
•
12 V voltage monitoring or VID5 input?
The ADT7476 offers multifunctional pins that can be
reconfigured to suit different system requirements and
physical layouts. These multifunction pins are software
programmable.
Rev. A | Page 38 of 72
•
How many fans are supported in system, three or four?
This influences the choice of whether to use the
TACH4 pin or to reconfigure it for the THERM
function.
•
Is the CPU fan to be controlled using the ADT7476, or
will the CPU fan run at full speed 100% of the time?
•
If run at 100%, this frees up a PWM output, but the
system is louder.
•
Where will the ADT7476 be physically located in the
system?
This influences the assignment of the temperature measurement channels to particular system thermal zones. For
example, locating the ADT7476 close to the VRM controller
circuitry allows the VRM temperature to be monitored using
the local temperature channel.
ADT7476
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 1 =
AMBIENT TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
MUX
TMIN
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
TRANGE
TACHOMETER 3
AND 4
MEASUREMENT
0%
REMOTE 2 =
CPU TEMP
PWM1
TACH1
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 2
MEASUREMENT
0%
PWM
MIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
FRONT CHASSIS
PWM3
TACH3
REAR CHASSIS
05382-049
THERMAL CALIBRATION
Figure 48. Hardware Configuration Example
Recommended Implementation 1
• VRM temperature using local temperature sensor.
Configuring the ADT7476 as in Figure 49 provides the system
designer with the following features:
•
CPU temperature measured using the Remote 1
temperature channel.
•
Six VID inputs (VID0 to VID5) for VRM10 support.
•
•
Two PWM outputs for fan control of up to three fans.
The front and rear chassis fans are connected in parallel.
Ambient temperature measured through the Remote 2
temperature channel.
•
If not using VID5, it can be reconfigured as the 12 V
monitoring input.
•
Bidirectional THERM pin allows the monitoring of
PROCHOT output from an Intel Pentium 4 processor, for
example, or can be used as an overtemperature THERM
output.
•
SMBALERT system interrupt output.
•
Three TACH fan speed measurement inputs.
•
VCC measured internally through Pin 4.
•
CPU core voltage measurement (VCORE).
•
2.5 V measurement input used to monitor CPU current
(connected to VCOMP output of ADP316x VRM controller).
This is used to determine CPU power consumption.
• 5 V measurement input.
Rev. A | Page 39 of 72
ADT7476
ADT7476
FRONT
CHASSIS
FAN
TACH2
PWM1
TACH1
CPU FAN
PWM3
REAR
CHASSIS
FAN
5(VRM9)/6(VRM10)
VID[0:4]/VID[0.5]
TACH3
D2+
D2–
THERM
PROCHOT
AMBIENT
TEMPERATURE
CPU
D1+
D1–
VCC
SDA
+5VIN
SCL
+12VIN/VID5
GND
ICH
05382-050
SMBALERT
Figure 49. Recommended Implementation 1
Recommended Implementation 2
•
VRM temperature using local temperature sensor.
Configuring the ADT7476 as in Figure 50 provides the system
designer with the following features:
•
CPU temperature measured using the Remote 1
temperature channel.
•
Six VID inputs (VID0 to VID5) for VRM10 support.
•
•
Three PWM outputs for fan control of up to three fans.
All three fans can be individually controlled.
Ambient temperature measured through the Remote 2
temperature channel.
•
If not using VID5, it can be reconfigured as the 12 V
monitoring input.
•
Bidirectional THERM pin allows the monitoring of
PROCHOT output/input from an Intel Pentium 4
processor, for example, or can be used as an
overtemperature THERM output.
•
Three TACH fan speed measurement inputs.
•
VCC measured internally through Pin 4.
•
CPU core voltage measurement (VCORE).
•
2.5 V measurement input used to monitor CPU current
(connected to VCOMP output of ADP316x VRM controller).
This is used to determine CPU power consumption.
•
5 V measurement input.
Rev. A | Page 40 of 72
ADT7476
ADT7476
FRONT
CHASSIS
FAN
TACH2
PWM1
PWM2
TACH1
CPU FAN
PWM3
REAR
CHASSIS
FAN
5(VRM9)/6(VRM10)
VID[0:4]/VID[0.5]
TACH3
D2+
D2–
THERM
PROCHOT
AMBIENT
TEMPERATURE
CPU
D1+
D1–
SDA
VCC
SCL
+5VIN
ICH
+12VIN/VID5
05382-051
GND
Figure 50. Recommended Implementation 2
STEP 2: CONFIGURING THE MUX
After the system hardware configuration is determined, the fans
can be assigned to particular temperature channels. Not only
can fans be assigned to individual channels, but the behavior
of the fans is also configurable. For example, fans can be run
under automatic fan control, can be run manually (under
software control), or can be run at the fastest speed calculated by multiple temperature channels. The mux is the bridge
between temperature measurement channels and the three
PWM outputs.
Bits [7:5] (BHVR) of Register 0x5C, Register 0x5D, and
Register 0x5E (PWM configuration registers) control the
behavior of the fans connected to the PWM1, PWM2, and
PWM3 outputs. The values selected for these bits determine
how the mux connects a temperature measurement channel to a
PWM output.
101 = fastest speed calculated by local and Remote 2
temperature controls PWMx
110 = fastest speed calculated by all three temperature
channels controls PWMx
The fastest speed calculated options pertain to controlling
one PWM output based on multiple temperature channels.
The thermal characteristics of the three temperature zones
can be set to drive a single fan. An example would be the fan
turning on when Remote 1 temperature exceeds 60°C or if
the local temperature exceeds 45°C.
Other Mux Options
Bits [7:5] (BHVR), Register 0x5C, Register 0x5D, and
Register 0x5E.
011 = PWMx runs full speed
Automatic Fan Control Mux Options
100 = PWMx disabled (default)
Bits [7:5] (BHVR), Register 0x5C, Register 0x5D, and
Register 0x5E.
111 = manual mode. In manual mode, PWMx runs under
software control. In this mode, PWM duty cycle registers
(Register 0x30 to Register 0x32) are writable and control
the PWM outputs.
000 = Remote 1 temperature controls PWMx
001 = local temperature controls PWMx
010 = Remote 2 temperature controls PWMx
Rev. A | Page 41 of 72
ADT7476
MUX
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 1 =
AMBIENT TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TMIN
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
MUX
PWM
CONFIG
TRANGE
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 3
AND 4
MEASUREMENT
0%
PWM1
TACH1
TACHOMETER 2
MEASUREMENT
PWM
GENERATOR
TMIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
REMOTE 2 =
CPU TEMP
FRONT CHASSIS
PWM3
TACH3
REAR CHASSIS
05382-052
THERMAL CALIBRATION
Figure 51. Assigning Temperature Channels to Fan Channels
Mux Configuration Example
Example Mux Settings
This is an example of how to configure the mux in a system
using the ADT7476 to control three fans. The CPU fan sink
is controlled by PWM1, the front chassis fan is controlled by
PWM2, and the rear chassis fan is controlled by PWM3. The
mux is configured for the following fan control behavior:
Bits [7:5] (BHVR), PWM1 Configuration Register 0x5C.
•
PWM1 (CPU fan sink) is controlled by the fastest speed
calculated by the local (VRM temperature) and Remote 2
(processor) temperature. In this case, the CPU fan sink is
also used to cool the VRM.
•
PWM2 (front chassis fan) is controlled by the Remote 1
temperature (ambient).
•
PWM3 (rear chassis fan) is controlled by the Remote 1
temperature (ambient).
101 = Fastest speed calculated by local and Remote 2
temperature controls PWM1
Bits [7:5] (BHVR), PWM2 Configuration Register 0x5D.
000 = Remote 1 temperature controls PWM2
Bits [7:5] (BHVR), PWM3 Configuration Register 0x5E.
000 = Remote 1 temperature controls PWM3
These settings configure the mux, as shown in Figure 52.
Rev. A | Page 42 of 72
ADT7476
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 2 =
CPU TEMP
TRANGE
THERMAL CALIBRATION
0%
MUX
100%
PWM
MIN
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
TMIN
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
PWM
CONFIG
TRANGE
TACHOMETER 3
AND 4
MEASUREMENT
0%
PWM1
TACH1
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 2
MEASUREMENT
PWM
GENERATOR
TMIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
FRONT CHASSIS
PWM3
TACH3
REMOTE 1 =
AMBIENT TEMP
REAR CHASSIS
05382-053
THERMAL CALIBRATION
Figure 52. MUX Configuration Example
TMIN Registers
STEP 3: TMIN SETTINGS FOR THERMAL
CALIBRATION CHANNELS
Register 0x67, Remote 1 Temperature TMIN = 0x5A (90°C)
TMIN is the temperature at which the fans start to turn on under
automatic fan control. The speed at which the fan runs at TMIN
is programmed later. The TMIN values chosen are temperature
channel specific, for example, 25°C for ambient channel, 30°C
for VRM temperature, and 40°C for processor temperature.
TMIN is an 8-bit value, either twos complement or Offset 64,
that can be programmed in 1°C increments. A TMIN register
is associated with each temperature measurement channel:
Remote 1 local, and Remote 2 temperature. Once the TMIN value
is exceeded, the fan turns on and runs at the minimum PWM
duty cycle. The fan turns off once the temperature has dropped
below TMIN − THYST.
To overcome fan inertia, the fan is spun up until two valid TACH
rising edges are counted. (See the Fan Startup Timeout section
for more details.) In some cases, primarily for psycho-acoustic
reasons, it is desirable that the fan never switch off below TMIN.
When set, Bits [7:5] of Enhanced Acoustics Register 1 (0x62),
keep the fans running at the PWM minimum duty cycle, if the
temperature should fall below TMIN.
Register 0x68, Local Temperature TMIN = 0x5A (90°C)
Register 0x69, Remote 2 Temperature TMIN = 0x5A (90°C)
Enhance Acoustics Register 1 (Reg. 0x62)
Bit 7 (MIN3) = 0, PWM3 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
Bit 7 (MIN3) = 1, PWM3 runs at PWM3 minimum duty cycle
below TMIN − THYST.
Bit 6 (MIN2) = 0, PWM2 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
Bit 6 (MIN2) = 1, PWM2 runs at PWM2 minimum duty cycle
below TMIN − THYST.
Bit 5 (MIN1) = 0, PWM1 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
Bit 5 (MIN1) = 1, PWM1 runs at PWM1 minimum duty cycle
below TMIN − THYST.
Rev. A | Page 43 of 72
ADT7476
PWM DUTYCYCLE
100%
0%
TMIN
PWM
MIN
100%
PWM
CONFIG
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM
GENERATOR
TMIN
REMOTE 2 =
CPU TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TACH1
CPU FAN SINK
PWM
CONFIG
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM
GENERATOR
MUX
TMIN
TACHOMETER 1
MEASUREMENT
TACHOMETER 2
MEASUREMENT
TRANGE
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 3
AND 4
MEASUREMENT
0%
PWM2
TACH2
PWM
CONFIG
PWM
GENERATOR
TMIN
PWM1
FRONT CHASSIS
PWM3
TACH3
REMOTE 1 =
AMBIENT TEMP
REAR CHASSIS
05382-054
THERMAL CALIBRATION
Figure 53. Understanding the TMIN Parameter
STEP 4: PWMMIN FOR EACH PWM (FAN) OUTPUT
PWMMIN is the minimum PWM duty cycle at which each fan
in the system runs. It is also the start speed for each fan under
automatic fan control once the temperature rises above TMIN.
For maximum system acoustic benefit, PWMMIN should be as
low as possible. Depending on the fan used, the PWMMIN setting is usually in the 20% to 33% duty cycle range. This value
can be found through fan validation.
PWM DUTY CYCLE
100%
PWMMIN
0%
TEMPERATURE
M2
PW
M1
PW
PWM2MIN
PWM1MIN
0%
Figure 54. PWMMIN Determines Minimum PWM Duty Cycle
TMIN
TEMPERATURE
05382-056
TMIN
05382-055
PWM DUTY CYCLE
100%
More than one PWM output can be controlled from a single
temperature measurement channel. For example, Remote 1
Temperature can control PWM1 and PWM2 outputs. If two
different fans are used on PWM1 and PWM2, the fan
characteristics can be set up differently. As a result, Fan 1 driven
by PWM1 can have a different PWMMIN value than that of Fan 2
connected to PWM2. Figure 55 illustrates this as PWM1MIN
(front fan) is turned on at a minimum duty cycle of 20%, while
PWM2MIN (rear fan) turns on at a minimum of 40% duty cycle.
Note: Both fans turn on at exactly the same temperature,
defined by TMIN.
Figure 55. Operating Two Different Fans from a Single Temperature Channel
Rev. A | Page 44 of 72
ADT7476
Programming the PWMMIN Registers
100%
PWM DUTY CYCLE
The PWMMIN registers are 8-bit registers that allow the minimum PWM duty cycle for each output to be configured
anywhere from 0% to 100%. This allows the minimum
PWM duty cycle to be set in steps of 0.39%.
The value to be programmed into the PWMMIN register is
given by
PWMMAX
PWMMIN
TMIN
Example 1: For a minimum PWM duty cycle of 50%
TEMPERATURE
05382-057
0%
Value (decimal) = PWMMIN/0.39
Figure 56. PWMMAX Determines Maximum PWM Duty Cycle
Below the THERM Temperature Limit
Value (decimal) = 50/0.39 = 128 (decimal)
Value = 128 (decimal) or 80 (hex)
Programming the PWMMAX Registers
Example 2: For a minimum PWM duty cycle of 33%
The PWMMAX registers are 8-bit registers that allow the
maximum PWM duty cycle for each output to be configured
anywhere from 0% to 100%. This allows the maximum PWM
duty cycle to be set in steps of 0.39%.
Value (decimal) = 33/0.39 = 85 (decimal)
Value = 85 (decimal) or 54 (hex)
PWMMIN Registers
Register 0x64, PWM1 Minimum Duty Cycle = 0x80 (50% default)
The value to be programmed into the PWMMAX register is
given by
Register 0x65, PWM2 Minimum Duty Cycle = 0x80 (50% default)
Value (decimal) = PWMMAX/0.39
Register 0x66, PWM3 Minimum Duty Cycle = 0x80 (50% default)
Example 1: For a maximum PWM duty cycle of 50%
Note on Fan Speed and PWM Duty Cycle
The PWM duty cycle does not directly correlate to fan speed in
RPM. Running a fan at 33% PWM duty cycle does not equate to
running the fan at 33% speed. Driving a fan at 33% PWM duty
cycle actually runs the fan at closer to 50% of its full speed. This
is because fan speed in %RPM generally relates to the square
root of PWM duty cycle. Given a PWM square wave as the
drive signal, fan speed in RPM approximates to
Value (decimal) – 50/0.39 = 128 (decimal)
Value = 128 (decimal) or 80 (hex)
Example 2: For a minimum PWM duty cycle of 75%
Value (decimal) = 75/0.39 = 85 (decimal)
Value = 192 (decimal) or C0 (hex)
PWMMAX Registers
% fanspeed = PWM Duty Cycle × 10
Register 0x38, PWM1 Maximum Duty Cycle = 0xFF
(100% default)
STEP 5: PWMMAX FOR PWM (FAN) OUTPUTS
PWMMAX is the maximum duty cycle at which each fan in the
system runs under the automatic fan speed control loop. For
maximum system acoustic benefit, PWMMAX should be as low as
possible, but should be capable of maintaining the processor
temperature limit at an acceptable level. If the THERM
temperature limit is exceeded, the fans are still boosted to
100% for fail-safe cooling.
Register 0x39, PWM2 Maximum Duty Cycle = 0xFF
(100% default)
Register 0x3A, PWM3 Maximum Duty Cycle = 0xFF
(100% default)
There is a PWMMAX limit for each fan channel. The default
value of this register is 0xFF and has no effect unless it is
programmed.
Rev. A | Page 45 of 72
ADT7476
TRANGE is the range of temperature over which automatic fan
control occurs once the programmed TMIN temperature has
been exceeded. TRANGE is the temperature range between PWMMIN
and 100% PWM where the fan speed changes linearly. Otherwise
stated, it is the line drawn between the TMIN/PWMMIN and the
(TMIN + TRANGE)/PWM100% intersection points.
As TRANGE is changed, the slope changes. As TRANGE gets
smaller, the fans reach 100% speed with a smaller temperature
change.
100%
PWM DUTY CYCLE
STEP 6: TRANGE FOR TEMPERATURE CHANNELS
TRANGE
100%
0%
TMIN
Figure 59. Increasing TRANGE Changes the AFC slope
05382-058
TMIN
TEMPERATURE
Figure 57. TRANGE Parameter Affects Cooling Slope
PWM DUTY CYCLE
100%
The TRANGE is determined by the following procedure:
1.
Determine the maximum operating temperature for that
channel (for example, 70°C).
2.
Determine experimentally the fan speed (PWM duty cycle
value) that does not exceed the temperature at the worstcase operating points. For example, 70°C is reached when
the fans are running at 50% PWM duty cycle.
4.
Determine the slope of the required control loop to meet
these requirements.
Using the ADT7476 evaluation software, you can
graphically program and visualize this functionality. Ask
your local Analog Devices representative for details.
0%
TRANGE
TMIN–HYST
Figure 60. Changing PWMMAX Does Not Change the AFC Slope
Selecting TRANGE
The TRANGE value can be selected for each temperature channel:
Remote 1, local, and Remote 2 temperature. Bits [7:4] (TRANGE)
of Register 0x5F to Register 0x61 define the TRANGE value for
each temperature channel.
100%
50%
33%
TMIN
05382-059
0%
30°C
MAX
PWM
10%
As PWMMIN is changed, the automatic fan control slope
changes.
PWM DUTY CYCLE
40°C
45°C
54°C
PWMMIN
0%
3.
30°C
05382-060
TMIN–HYST
05382-061
PWM DUTY CYCLE
10%
Figure 58. Adjusting PWMMIN Changes the Automatic Fan Control Slope
Rev. A | Page 46 of 72
ADT7476
100
Table 17. Selecting a TRANGE Value
TRANGE (°C)
2
2.5
3.33
4
5
6.67
8
10
13.33
16
20
26.67
32 (default)
40
53.33
80
3.33°C
PWM DUTY CYCLE (%)
80
4°C
5°C
70
6.67°C
60
8°C
10°C
50
13.3°C
16°C
40
20°C
30
26.6°C
32°C
20
40°C
10
0
0
53.3°C
20
40
60
80
TEMPERATURE ABOVE TMIN
100
120
80°C
(A)
100
2°C
2.5°C
90
3.33°C
80
Register 0x5F configures Remote 1 TRANGE; Register 0x60 configures local
TRANGE; Register 0x61 configures Remote 2 TRANGE.
Actual Changes in PWM Output (Advance Acoustics
Settings)
While the automatic fan control algorithm describes the
general response of the PWM output, it is also necessary to
note the enhance acoustics registers (0x62 and 0x63) can be
used to set/clamp the maximum rate of change of PWM
output for a given temperature zone. This means that if
TRANGE is programmed with an AFC slope that is quite steep,
a relatively small change in temperature could cause a large
change in PWM output and possibly an audible change in
fan speed, which can be noticeable/annoying to end users.
4°C
5°C
70
6.67°C
60
8°C
10°C
50
13.3°C
16°C
40
20°C
30
26.6°C
32°C
20
40°C
10
0
0
53.3°C
20
40
60
80
TEMPERATURE ABOVE TMIN
100
120
80°C
(B)
Figure 61. TRANGE vs. Actual Fan Speed (Not PWM Drive) Profile
Decreasing the speed the PWM output changes, by
programming the smoothing on the appropriate temperature
channels (Register 0x62 and Register 0x63), changes how fast
the fan speed increases/decreases in the event of a temperature
spike. The PWM duty cycle increases until the PWM duty cycle
reaches the appropriate duty cycle as defined by the AFC curve.
The graphs in Figure 61 assume the fan starts from 0% PWM
duty cycle. Clearly, the minimum PWM duty cycle, PWMMIN,
needs to be factored in to see how the loop actually performs
in the system. Figure 62 shows how TRANGE is affected when
the PWMMIN value is set to 20%. It can be seen that the fan
actually runs at about 45% fan speed when the temperature
exceeds TMIN.
Figure 61 shows PWM duty cycle vs. temperature for each
TRANGE setting. The lower graph shows how each TRANGE setting
affects fan speed vs. temperature. As can be seen from the
graph, the effect on fan speed is nonlinear.
Rev. A | Page 47 of 72
05382-062
1
2°C
2.5°C
90
FAN SPEED (% OF MAX)
Bits [7:4]
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
1
ADT7476
100
2°C
4°C
80
PWM DUTY CYCLE (%)
5°C
70
6.67°C
8°C
60
10°C
50
13.3°C
16°C
40
20°C
30
26.6°C
32°C
20
40
60
80
TEMPERATURE ABOVE TMIN
100
120
50
AMBIENT TEMPERATURE
40
30
80°C
0
0
10
20
(A)
100
2.5°C
90
FAN SPEED (% MAX RPM)
5°C
70
6.67°C
60
8°C
10°C
50
13.3°C
40
16°C
20°C
30
26.6°C
20
60
70
80
90
100
40°C
10
80°C
80
90
100
CPU TEMPERATURE
60
AMBIENT TEMPERATURE
50
40
30
0
05382-063
120
70
10
53.3°C
100
VRM TEMPERATURE
20
32°C
40
60
80
TEMPERATURE ABOVE TMIN
50
80
4°C
20
40
90
3.33°C
80
FAN SPEED (% OF MAX)
100
2°C
0
0
30
TEMPERATURE ABOVE TMIN
0
10
20
30
40
50
60
70
TEMPERATURE ABOVE TMIN
(B)
05382-064
20
CPU TEMPERATURE
60
10
53.3°C
0
0
70
20
40°C
10
VRM TEMPERATURE
90
3.33°C
80
PWM DUTY CYCLE (%)
100
2.5°C
90
Figure 63. TRANGE and % Fan Speed Slopes for VRM, Ambient, and
CPU Temperature Channels
Figure 62. TRANGE and % Fan Speed Slopes with PWMMIN = 20%
STEP 7: TTHERM FOR TEMPERATURE CHANNELS
Example: Determining TRANGE for Each Temperature
Channel
The following example shows how the different TMIN and TRANGE
settings can be applied to three different thermal zones. In this
example, the following TRANGE values apply:
TRANGE = 80°C for ambient temperature
TRANGE = 53.33°C for CPU temperature
TRANGE = 40°C for VRM temperature
TTHERM is the absolute maximum temperature allowed on a
temperature channel. Above this temperature, a component
such as the CPU or VRM might be operating beyond its safe
operating limit. When the temperature measured exceeds
TTHERM, all fans are driven at 100% PWM duty cycle (full speed)
to provide critical system cooling.
This example uses the MUX configuration described in Step 2,
with the ADT7476 connected as shown in Figure 52. Both CPU
temperature and VRM temperature drive the CPU fan connected to PWM1. Ambient temperature drives the front chassis
fan and rear chassis fan connected to PWM2 and PWM3. The
front chassis fan is configured to run at PWMMIN = 20%. The
rear chassis fan is configured to run at PWMMIN = 30%. The
CPU fan is configured to run at PWMMIN = 10%.
The fans remain running at 100% until the temperature drops
below TTHERM minus hysteresis, where hysteresis is the number
programmed into the hysteresis registers (0x6D and 0x6E). The
default hysteresis value is 4°C.
Note: The control range for 4-wire fans is much wider than that
of 3-wire fans. In many cases, 4-wire fans can start with a PWM
drive of as little as 20% or less. In extreme cases, some 3-wire
fans cannot run unless a PWM drive of 60% or more is applied.
Rev. A | Page 48 of 72
ADT7476
The TTHERM limit should be considered the maximum worst-case
THERM Hysteresis
operating temperature of the system. Because exceeding any
TTHERM limit runs all fans at 100%, it has very negative acoustic
THERM hysteresis on a particular channel is configured via the
hysteresis settings below (Register 0x6D and Register 0x6E). For
example, setting hysteresis on the Remote 1 channel also sets
the hysteresis on Remote 1 THERM.
effects. Ultimately, this limit should be set up as a fail-safe, and
one should ensure that it is not exceeded under normal system
operating conditions.
Hysteresis Registers
Note that TTHERM limits are nonmaskable and affect the fan
Register 0x6D, Remote 1, Local Hysteresis Register
speed no matter how automatic fan control settings are
configured. This allows some flexibility, because a TRANGE value
can be selected based on its slope, while a hard limit (such as
70°C), can be programmed as TMAX (the temperature at which
the fan reaches full speed) by setting TTHERM to that limit (for
Bits [7:4], Remote 1 Temperature hysteresis (4°C default).
Bits [3:0], Local Temperature hysteresis (4°C default).
Register 0x6E, Remote 2 Temperature Hysteresis Register
example, 70°C).
Bits [7:4], Remote 2 Temperature hysteresis (4°C default).
THERM Registers
Because each hysteresis setting is four bits, hysteresis values
are programmable from 1°C to 15°C. It is not recommended
that hysteresis values ever be programmed to 0°C, because this
disables hysteresis. In effect, this would cause the fans to cycle
(during a THERM event) between normal speed and 100%
speed, or, while operating close to TMIN, between normal speed
and off, creating unsettling acoustic noise.
Register 0x6A, Remote 1 THERM limit = 0x64 (100°C default)
Register 0x6B, Local THERM limit = 0x64 (100°C default)
Register 0x6C, Remote 2 THERM limit = 0x64 (100°C default)
TRANGE
PWM DUTYCYCLE
100%
0%
TMIN
TTHERM
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 2 =
CPU TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TMIN
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
MUX
PWM
CONFIG
TRANGE
0%
PWM1
TACH1
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 2
MEASUREMENT
PWM
GENERATOR
TMIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 3
AND 4
MEASUREMENT
FRONT CHASSIS
PWM3
TACH3
REMOTE 1 =
AMBIENT TEMP
REAR CHASSIS
Figure 64. How TTHERM Relates to Automatic Fan Control
Rev. A | Page 49 of 72
05382-065
THERMAL CALIBRATION
ADT7476
STEP 8: THYST FOR TEMPERATURE CHANNELS
In some applications, it is required that fans not turn off below
TMIN, but remain running at PWMMIN. Bits [7:5] of Enhance
Acoustics Register 1 (0x62) allow the fans to be turned off or to
be kept spinning below TMIN. If the fans are always on, the THYST
value has no effect on the fan when the temperature drops
below TMIN.
THYST is the amount of extra cooling a fan provides after the
temperature measured has dropped back below TMIN before the
fan turns off. The premise for temperature hysteresis (THYST) is
that, without it, the fan would merely chatter, or cycle on and
off regularly, whenever the temperature is hovering at about the
TMIN setting.
THERM Hysteresis
The THYST value chosen determines the amount of time needed
for the system to cool down or heat up as the fan turns on and
off. Values of hysteresis are programmable in the range 1°C to
15°C. Larger values of THYST prevent the fans from chattering on
and off. The THYST default value is set at 4°C.
Any hysteresis programmed via Register 0x6D and
Register 0x6E also applies to hysteresis on the appropriate
THERM channel.
The THYST setting applies not only to the temperature hysteresis
for fan on/off, but the same setting is used for the TTHERM
hysteresis value, described in Step 6. Therefore, programming
Register 0x6D and Register 0x6E sets the hysteresis for both fan
on/off and the THERM function.
TRANGE
PWM DUTYCYCLE
100%
0%
TTHERM
THERMAL CALIBRATION
PWM
MIN
100%
PWM
CONFIG
PWM
GENERATOR
TMIN
REMOTE 2 =
CPU TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TMIN
LOCAL =
VRM TEMP
TRANGE
THERMAL CALIBRATION
0%
PWM
MIN
100%
TACHOMETER 1
MEASUREMENT
PWM
CONFIG
PWM
GENERATOR
MUX
PWM
CONFIG
TRANGE
0%
PWM1
TACH1
CPU FAN SINK
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 2
MEASUREMENT
PWM
GENERATOR
TMIN
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
PWM2
TACH2
RAMP
CONTROL
(ACOUSTIC
ENHANCEMENT)
TACHOMETER 3
AND 4
MEASUREMENT
FRONT CHASSIS
PWM3
TACH3
REMOTE 1 =
AMBIENT TEMP
REAR CHASSIS
Figure 65. The THYST Value Applies to Fan On/Off Hysteresis and THERM Hysteresis
Rev. A | Page 50 of 72
05382-066
TMIN
ADT7476
010 = 12.5 seconds
011 = 7.5 seconds
100 = 4.7 seconds
101 = 3.1 seconds
110 = 1.6 seconds
111 = 0.8 seconds
Enhance Acoustics Register 1 (Reg. 0x62)
Bit 7 MIN3 = 0, PWM3 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
Bit 7 MIN3 = 1, PWM3 runs at PWM3 minimum duty cycle
below TMIN − THYST.
Bit 6 MIN2 = 0, PWM2 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
Bits [6:4] ACOU2, selects the ramp rate for PWM outputs
associated with the Remote 2 temperature input.
Bit 6 MIN2 = 1, PWM2 runs at PWM2 minimum duty cycle
below TMIN − THYST.
Bit 5 MIN1 = 0, PWM1 is off (0% PWM duty cycle) when
temperature is below TMIN − THYST.
Bit 5 MIN1 = 1, PWM1 runs at PWM1 minimum duty cycle
below TMIN − THYST.
Configuration Register 6 (0x10)
Bit 0 SLOW, 1 slows the ramp rate for PWM changes associated
with the Remote 1 temperature channel by 4. Configuration
Register 6 (0x10)
Bit 1 SLOW, 1 slows the ramp rate for PWM changes associated
with the local temperature channel by 4.
Configuration Register 6 (0x10)
Bit 2 SLOW, 1 slows the ramp rate for PWM changes associated
with the Remote 2 temperature channel by 4.
Configuration Register 6 (0x10)
Bit 7 ExtraSlow, 1 slows the ramp rate for all fans by a factor
of 39.2%.
The following sections list the ramp-up times when the
SLOW bit is set for each temperature monitoring channel.
Enhance Acoustics Register 1 (0x62)
Bits [2:0] ACOU, selects the ramp rate for PWM outputs
associated with the Remote Temperature 1 input.
000 = 37.5 seconds
001 = 18.8 seconds
010 = 12.5 seconds
011 = 7.5 seconds
100 = 4.7 seconds
101 = 3.1 seconds
110 = 1.6 seconds
111 = 0.8 seconds
000 = 37.5 seconds
001 = 18.8 seconds
010 = 12.5 seconds
011 = 7.5 seconds
100 = 4.7 seconds
101 = 3.1 seconds
110 = 1.6 seconds
111 = 0.8 seconds
When Bit 7 of Configuration Register 6 (0x10) = 1, the above
ramp rates change to the following values:
000 = 52.2 seconds
001 = 26.1 seconds
010 = 17.4 seconds
011 = 10.4 seconds
100 = 6.5 seconds
101 = 4.4 seconds
110 = 2.2 seconds
111 = 1.1 seconds
Setting the appropriate slow bit, Bits [2:0] of Configuration
Register 6 (0x10), slows the ramp rate further by a factor of 4.
FAN PRESENCE DETECT
This feature is used to determine if a 4-wire fan is directly
connected to a PWM output. This feature does not work for
3-wire fans. To detect whether a 4-wire fan is connected
directly to a PWM output, the following must be performed
in this order:
1.
Drive the appropriate PWM outputs to 100% duty cycle.
2.
Set Bit 0 of Configuration Register 2 (0x73).
3.
Wait 5 ms.
4.
Program fans to run at a different speed if necessary.
5.
Read the state of Bits [3:1] of Configuration Register 2
(0x73). The state of these bits reflects whether a 4-wire fan
is connected directly to the PWM output.
Enhance Acoustics Register 2 (0x63)
Bits [2:0] ACOU3, selects the ramp rate for PWM outputs
associated with the local temperature channel.
000 = 37.5 sec
001 = 18.8 sec
As the detection time only takes 5 ms, programming the
PWM outputs to 100% and then back to its normal speed is
not noticeable, in most cases.
Rev. A | Page 51 of 72
ADT7476
How Fan Presence Detect Works
XNOR TREE TEST MODE
4-wire fans typically have an internal pull-up to 4.75 V ±10%,
which typically sources 5 mA. While the detection cycle is on,
an internal current sink is turned on, sinking current from the
fan’s internal pull-up. By driving some of the current from the
fan’s internal pull-up (~100 μA) the logic buffer switches to a
defined logic state. If this state is high, a fan is present; if the
state is low, no fan is present.
The ADT7476 includes an XNOR tree test mode. This mode
is useful for in-circuit test equipment at board-level testing. By
applying stimulus to the pins included in the XNOR tree, it is
possible to detect opens, or shorts, on the system board.
Note: The PWM input voltage should be clamped to 3.3 V. This
ensures the PWM output is not pulled to a voltage higher than
the maximum allowable voltage on that pin (3.6 V).
Figure 66 shows the signals that are exercised in the XNOR tree
test mode.
The XNOR tree test is invoked by setting Bit 0 (XEN) of the
XNOR tree test enable register (0x6F).
VID0
VID1
FAN SYNC
When two ADT7476s are used in a system, it is possible to
synchronize them so that one PWM channel from each device
can be effectively OR’ed together to create a PWM output that
reflects the maximum speed of the two OR’ed PWMs. This
OR’ed PWM can in turn be used to drive a chassis fan. See
the Analog Devices website, located at www.analog.com, for
information on the Fan SYNC function.
VID2
VID3
VID4
TACH1
STANDBY MODE
TACH2
The ADT7476 has been specifically designed to respond to the
STBY supply. In computers that support S3 and S5 states, the
core voltage of the processor is lowered in these states. When
monitoring THERM, the THERM timer should be disabled
during these states.
TACH3
TACH4
PWM3
PWM1/XTO
05382-067
PWM2
When the VCCP voltage drops below the VCCP low limit, the
following occurs:
1.
Status Bit 1 (VCCP) in Status Register 1 is set.
2.
SMBALERT is generated, if enabled.
POWER-ON DEFAULT
3.
THERM monitoring is disabled. The THERM timer
should hold its value prior to the S3 or S5 state.
When the ADT7476 is powered up, monitoring is off by default
and the PWM outputs go to 100%. All necessary registers then
need to be configured via the SMBus for the appropriate
functions to operate.
Once the core voltage, VCCP, goes above the VCCP low limit,
everything is re-enabled and the system resumes normal
operation.
Figure 66. XNOR Tree Test
Rev. A | Page 52 of 72
ADT7476
REGISTER TABLES
Table 18. ADT7476 Registers
Address
0x10
R/W
R/W
Description
Configuration
Register 6
Bit 7
ExtraSlow
Bit 6
VCCP
Low
Bit 5
MasterEn
Bit 4
SlaveEn
Bit 2
SLOW
Remote 2
Bit 1
SLOW
Local
Bit 0
SLOW Remote
1
Default
0x00
Lockable
Yes
RES
Bit 3
THERM in
Manual
RES
0x11
R
RES
RES
RES
0x20
R
9
8
0x21
R
9
0x22
R
0x23
R
0x24
R
0x25
R
0x26
R
0x27
R
0x28
R
0x29
R
0x2A
R
0x2B
R
0x2C
R
0x2D
R
0x2E
R
0x2F
R
0x30
R/W
0x31
R/W
0x32
R/W
0x38
R/W
0x39
R/W
0x3A
R/W
0x3D
R
0x3E
R
0x40
R/W
0x41
R
Configuration
Register 7
2.5 V
Measurement
VCCP
Measurement
VCC
Measurement
5V
Measurement
12 V
Measurement
Remote 1
Temperature
Local
Temperature
Remote 2
Temperature
TACH1 Low
Byte
TACH1 High
Byte
TACH2 Low
Byte
TACH2 High
Byte
TACH3 Low
Byte
TACH3 High
Byte
TACH4 Low
Byte
TACH4 High
Byte
PWM1 Current
Duty Cycle
PWM2 Current
Duty Cycle
PWM3 Current
Duty Cycle
PWM1 Max
Duty Cycle
PWM2 Max
Duty Cycle
PWM3 Max
Duty Cycle
Device ID
Register
Company ID
Number
Configuration
Register 1
Interrupt
Status
Register 1
RES
RES
DisTHERMHys
0x00
Yes
7
6
5
4
3
2
0x00
8
7
6
5
4
3
2
0x00
9
8
7
6
5
4
3
2
0x00
9
8
7
6
5
4
3
2
0x00
9
8
7
6
5
4
3
2
0x00
9
8
7
6
5
4
3
2
0x80
9
8
7
6
5
4
3
2
0x80
9
8
7
6
5
4
3
2
0x80
7
6
5
4
3
2
1
0
0x00
15
14
13
12
11
10
9
8
0x00
7
6
5
4
3
2
1
0
0x00
15
14
13
12
11
10
9
8
0x00
7
6
5
4
3
2
1
0
0x00
15
14
13
12
11
10
9
8
0x00
7
6
5
4
3
2
1
0
0x00
15
14
13
12
11
10
9
8
0x00
7
6
5
4
3
2
1
0
0xFF
7
6
5
4
3
2
1
0
0xFF
7
6
5
4
3
2
1
0
0xFF
7
6
5
4
3
2
1
0
0xFF
Yes
7
6
5
4
3
2
1
0
0xFF
Yes
7
6
5
4
3
2
1
0
0xFF
Yes
7
6
5
4
3
2
1
0
0x76
7
6
5
4
3
2
1
0
0x41
RES
TODIS
FSPDIS
Vx1
FSPD
RDY
LOCK
STRT
0x04
OOL
R2T
LT
R1T
5V
VCC
VCCP
2.5 V/THERM
0x00
Rev. A | Page 53 of 72
Yes
ADT7476
Address
0x42
R/W
R
0x43
0x44
R/W
R/W
0x45
R/W
0x46
0x47
0x48
0x49
0x4A
0x4B
0x4C
0x4D
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0x4E
R/W
0x4F
R/W
0x50
R/W
0x51
R/W
0x52
R/W
0x53
R/W
0x54
R/W
0x55
R/W
0x56
R/W
0x57
R/W
0x58
R/W
0x59
R/W
0x5A
R/W
0x5B
R/W
0x5C
R/W
0x5D
R/W
Description
Interrupt
Status
Register 2
VID Code
2.5 V Low
Limit
2.5 V High
Limit
VCCP Low Limit
VCCP High Limit
VCC Low Limit
VCC High Limit
5 V Low Limit
5 V High Limit
12 V Low Limit
12 V High
Limit
Remote 1
Temp Low
Limit
Remote 1
Temp High
Limit
Local Temp
Low Limit
Local Temp
High Limit
Remote 2
Temp Low
Limit
Remote 2
Temp High
Limit
TACH1
Minimum Low
Byte
TACH1
Minimum
High Byte
TACH2
Minimum Low
Byte
TACH2
Minimum
High Byte
TACH3
Minimum Low
Byte
TACH3
Minimum
High Byte
TACH4
Minimum Low
Byte
TACH4
Minimum
High Byte
PWM1
Configuration
Register
PWM2
Configuration
Register
Bit 7
D2 FAULT
Bit 6
D1
FAULT
Bit 5
F4P/GPIO4
Bit 4
FAN3
Bit 3
FAN2
Bit 2
FAN1
Bit 1
OVT
Bit 0
12 V/VC
Default
0x00
VIDSEL
7
THLD
6
VID5
5
VID4
4
VID3
3
VID2
2
VID1
1
VID0
0
0x1F
0x00
7
6
5
4
3
2
1
0
0xFF
7
7
7
7
7
7
7
7
6
6
6
6
6
6
6
6
5
5
5
5
5
5
5
5
4
4
4
4
4
4
4
4
3
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0x00
0xFF
0x00
0xFF
0x00
0xFF
0x00
0xFF
7
6
5
4
3
2
1
0
0x81
7
6
5
4
3
2
1
0
0x7F
7
6
5
4
3
2
1
0
0x81
7
6
5
4
3
2
1
0
0x7F
7
6
5
4
3
2
1
0
0x81
7
6
5
4
3
2
1
0
0x7F
7
6
5
4
3
2
1
0
0xFF
15
14
13
12
11
10
9
8
0xFF
7
6
5
4
3
2
1
0
0xFF
15
14
13
12
11
10
9
8
0xFF
7
6
5
4
3
2
1
0
0xFF
15
14
13
12
11
10
9
8
0xFF
7
6
5
4
3
2
1
0
0xFF
15
14
13
12
11
10
9
8
0xFF
BHVR
BHVR
BHVR
INV
RES
SPIN
SPIN
SPIN
0x62
Yes
BHVR
BHVR
BHVR
INV
RES
SPIN
SPIN
SPIN
0x62
Yes
Rev. A | Page 54 of 72
Lockable
ADT7476
Address
0x5E
R/W
R/W
0x5F
R/W
0x60
R/W
0x61
R/W
0x62
R/W
0x63
R/W
0x64
R/W
0x65
R/W
0x66
R/W
0x67
R/W
0x68
R/W
0x69
R/W
0x6A
R/W
0x6B
R/W
0x6C
R/W
0x6D
R/W
0x6E
R/W
0x6F
R/W
0x70
R/W
0x71
R/W
0x72
R/W
0x73
R/W
0x74
R/W
0x75
R/W
0x76
R/W
0x77
R/W
Description
PWM3
Configuration
Register
Remote 1
TRANGE/PWM1
Frequency
Local
TRANGE/PWM2
Frequency
Remote 2
TRANGE/PWM3
Frequency
Enhance
Acoustics Reg.
1
Enhance
Acoustics Reg.
2
PWM1 Min
Duty Cycle
PWM2 Min
Duty Cycle
PWM3 Min
Duty Cycle
Remote 1
Temp TMIN
Local Temp
TMIN
Remote 2
Temp TMIN
Remote 1
THERM Temp
Limit
Local THERM
Temp Limit
Remote 2
THERM Temp
Limit
Remote 1 and
Local
Temp/TMIN
Hysteresis
Remote 2
Temp/TMIN
Hysteresis
XNOR Tree
Test Enable
Remote 1
Temperature
Offset
Local
Temperature
Offset
Remote 2
Temperature
Offset
Configuration
Register 2
Interrupt Mask
Register 1
Interrupt Mask
Register 2
Extended
Resolution 1
Extended
Resolution 2
Bit 7
BHVR
Bit 6
BHVR
Bit 5
BHVR
Bit 4
INV
Bit 3
RES
Bit 2
SPIN
Bit 1
SPIN
Bit 0
SPIN
Default
0x62
Lockable
Yes
RANGE
RANGE
RANGE
RANGE
HF/LF
FREQ
FREQ
FREQ
0XC4
Yes
RANGE
RANGE
RANGE
RANGE
HF/LF
FREQ
FREQ
FREQ
0XC4
Yes
RANGE
RANGE
RANGE
RANGE
HF/LF
FREQ
FREQ
FREQ
0XC4
Yes
MIN3
MIN2
MIN1
SYNC
EN1
ACOU
ACOU
ACOU
0X00
Yes
EN2
ACOU2
ACOU2
ACOU2
EN3
ACOU3
ACOU3
ACOU3
0X00
Yes
7
6
5
4
3
2
1
0
0X80
Yes
7
6
5
4
3
2
1
0
0X80
Yes
7
6
5
4
3
2
1
0
0X80
Yes
7
6
5
4
3
2
1
0
0X5A
Yes
7
6
5
4
3
2
1
0
0X5A
Yes
7
6
5
4
3
2
1
0
0X5A
Yes
7
6
5
4
3
2
1
0
0X64
Yes
7
6
5
4
3
2
1
0
0X64
Yes
7
6
5
4
3
2
1
0
0X64
Yes
HYSR1
HYSR1
HYSR1
HYSR1
HYSL
HYSL
HYSL
HYSL
0X44
Yes
HYSR2
HYSR2
HYSR2
HYRS
RES
RES
RES
RES
0X40
Yes
RES
RES
RES
RES
RES
RES
RES
XEN
0X00
Yes
7
6
5
4
3
2
1
0
0X00
Yes
7
6
5
4
3
2
1
0
0X00
Yes
7
6
5
4
3
2
1
0
0X00
Yes
RES
CONV
ATTN
AVG
Fan3Detect
Fan2Detect
Fan1Detect
FanPresenceDT
0X00
Yes
OOL
R2T
LT
R1T
5V
VCC
VCCP
2.5 V/ THERM
0X00
D2
D1
F4P
FAN3
FAN2
FAN1
OVT
12 V/VC
0X00
5V
5V
VCC
VCC
VCCP
VCCP
2.5 V
2.5 V
0X00
TDM2
TDM2
LTMP
LTMP
TDM1
TDM1
12 V
12 V
0X00
Rev. A | Page 55 of 72
ADT7476
Address
0x78
R/W
R/W
Description
Configuration
Register 3
Bit 7
DC4
Bit 6
DC3
Bit 5
DC2
Bit 4
DC1
Bit 3
FAST
Bit 2
BOOST
Bit 0
ALERT Enable
Default
0x00
TMR
Bit 1
THERM/
2.5V
TMR
0x79
R
TMR
TMR
TMR
TMR
TMR
0x7A
R/W
LIMT
LIMT
LIMT
LIMT
0x7B
R/W
FAN4
FAN4
FAN3
0x7C
R/W
THERM Timer
Status
THERM Timer
Limit
TACH Pulses
per Revolution
Configurations
Register 5
ASRT/TMRO
0x00
LIMT
LIMT
LIMT
LIMT
0x00
FAN3
FAN2
FAN2
FAN1
FAN1
0x55
R2
THERM
O/P Only
0x7D
R/W
Configuration
Register 4
BpAtt
12 V
Local
THERM
O/P
Only
BpAtt
5V
R1 THERM
O/P Only
VID/
GPIO
GPIO6P
GPIO6D
Temp
Offset
TWOS COMPL
0x01
Yes
BpAtt VCCP
BpAtt
2.5 V
Max/Full
on THERM
Pin14Func
Pin14Func
0x00
Yes
0x7E
0x7F
R
R
Test 1
Test 2
0x00
0x00
Yes
Yes
THERM
Disable
Do not write to these registers
Do not write to these registers
Lockable
Yes
Table 19. Register 0x10—Configuration Register 6 (Power-On Default = 0x00) 1, 2
Bit
[0]
[1]
[2]
[3]
[4]
[5]
[6]
Name
SlowFan
Remote 1
SlowFan
Local
SlowFan
Remote 2
THERM in
Manual
SlaveEn
MasterEn
VccpLow
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Description
When this bit is set, Fan 1 smoothing times are multiplied ×4 for Remote 1 temperature channel
(as defined in Register 0x62).
When this bit is set, Fan 2 smoothing times are multiplied ×4 for local temperature channel (as defined
in Register 0x63).
When this bit is set, Fan 3 smoothing times are multiplied ×4 for Remote 2 temperature channel
(as defined in Register 0x63).
When this bit is set, THERM is enabled in manual mode.1
Setting this bit configures the ADT7476 as a slave for use in fan sync mode.
Setting this bit configures the ADT7476 as a master for use in fan sync mode.
VCCPLO = 1. When the power is supplied from 3.3 V STANDBY and the core voltage (VCCP) drops below
its VCCP low limit value (Register 0x46), the following occurs:
• Status Bit 1 in Status Register 1 is set.
• SMBALERT is generated, if enabled.
•
PROCHOT monitoring is disabled.
• Everything is re-enabled once VCCP increases above the VCCP low limit.
When VCCP increases above the low limit:
• PROCHOT monitoring is enabled.
[7]
1
2
ExtraSlow
R/W
• Fans return to their programmed state after a spin-up cycle.
When this bit is set, all fan smoothing times are increased by a further 39.2%
A THERM event always overrides any fan setting (even when fans are disabled).
This register becomes read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Table 20. Register 0x11—Configuration Register 7 (Power-On Default = 0x00) 1
Bit
[0]
Name
DisTHERMHys
R/W
R/W
Description
Setting this bit to 1 disables THERM hysteresis.
[7:1]
Reserved
N/A
Reserved. Do not write to these bits.
1
This register becomes read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Rev. A | Page 56 of 72
ADT7476
Table 21. Voltage Reading Registers (Power-On Default = 0x00) 1
Register Address
0x20
0x21
0x22
0x23
0x24
R/W
Read-only
Read-only
Read-only
Read-only
Read-only
Description
Reflects the voltage measurement at the 2.5 V input on Pin 22 (8 MSBs of reading).
Reflects the voltage measurement at the VCCP input on Pin 23 (8 MSBs of reading). 2
Reflects the voltage measurement at the VCC input on Pin 4 (8 MSBs of reading). 3
Reflects the voltage measurement at the 5 V input on Pin 20 (8 MSBs of reading).
Reflects the voltage measurement at the 12 V input on Pin 21 (8 MSBs of reading).
1
If the extended resolution bits of these readings are also being read, the extended resolution registers (0x76, 0x77) must be read first. Once the extended resolution
registers have been read, the associated MSB reading registers are frozen until read. Both the extended resolution registers and the MSB registers are frozen.
2
If VCCPLow (Bit 7 of Register 0x40) is set, VCCP can control the sleep state of the ADT7476.
3
VCC (Pin 4) is the supply voltage for the ADT7476.
Table 22. Temperature Reading Registers (Power-On Default = 0x80)1, 2, 3
Register Address
0x25
R/W
Read-only
Description
Remote 1 temperature reading (8 MSBs of reading). 3, 4
0x26
0x27
Read-only
Read-only
Local temperature reading (8 MSBs of reading).
Remote 2 temperature reading (8 MSBs of reading). 3, 4
1
If the extended resolution bits of these readings are also being read, the extended resolution registers (Reg. 0x76, 0x77) must be read first. Once the extended
resolution registers have been read, all associated MSB reading registers are frozen until read. Both the extended resolution registers and the MSB registers are frozen.
2
These temperature readings can be in twos complement or Offset 64 format; this interpretation is determined by Bit 0 of Configuration Register 5 (0x7C).
3
In twos complement mode, a temperature reading of −128°C (0x80) indicates a diode fault (open or short) on that channel.
4
In Offset 64 mode, a temperature reading of −64°C (0x00) indicates a diode fault (open or short) on that channel.
Table 23. Fan Tachometer Reading Registers (Power-On Default = 0x00) 1
Register Address
0x28
0x29
0x2A
0x2B
0x2C
0x2D
0x2E
0x2F
1
R/W
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Read-only
Description
TACH1 low byte.
TACH1 high byte.
TACH2 low byte.
TACH2 high byte.
TACH3 low byte.
TACH3 high byte.
TACH4 low byte.
TACH4 high byte.
These registers count the number of 11.11 μs periods (based on an internal 90 kHz clock) that occur between a number of consecutive fan TACH pulses (default = 2).
The number of TACH pulses used to count can be changed using the fan pulses per revolution register (0x7B). This allows the fan speed to be accurately measured.
Because a valid fan tachometer reading requires that two bytes are read, the low byte must be read first. Both the low and high bytes are then frozen until read. At
power-on, these registers contain 0x0000 until such time as the first valid fan TACH measurement is read into these registers. This prevents false interrupts from
occurring while the fans are spinning up. A count of 0xFFFF indicates that a fan is one of the following:
• Stalled or blocked (object jamming the fan).
• Failed (internal circuitry destroyed).
• Not populated. (The ADT7476 expects to see a fan connected to each TACH. If a fan is not connected to that TACH, its TACH minimum high and low bytes should
be set to 0xFFFF.)
• Alternate function, for example, TACH4 reconfigured as THERM pin.
Table 24. Current PWM Duty Cycle Registers (Power-On Default = 0xFF) 1
Register Address
0x30
0x31
0x32
1
R/W
R/W
R/W
R/W
Description
PWM1 current duty cycle (0% to 100% duty cycle = 0x00 to 0xFF).
PWM2 current duty cycle (0% to 100% duty cycle = 0x00 to 0xFF).
PWM3 current duty cycle (0% to 100% duty cycle = 0x00 to 0xFF).
These registers reflect the PWM duty cycle driving each fan at any given time. When in automatic fan speed control mode, the ADT7476 reports the PWM duty cycles
back through these registers. The PWM duty cycle values vary according to temperature in automatic fan speed control mode. During fan startup, these registers
report back 0x00. In manual mode, the PWM duty cycle outputs can be set to any duty cycle value by writing to these registers.
Rev. A | Page 57 of 72
ADT7476
Table 25. Maximum PWM Duty Cycle (Power-On Default = 0xFF) 1, 2
R/W2
R/W
R/W
R/W
Register Address
0x38
0x39
0x3A
1
2
Description
Maximum duty cycle for PWM1 output, default = 100% (0xFF.)
Maximum duty cycle for PWM2 output, default = 100% (0xFF).
Maximum duty cycle for PWM3 output, default = 100% (0xFF).
These registers set the maximum PWM duty cycle of the PWM output.
This register becomes read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Table 26. Register 0x40—Configuration Register 1 (Power-On Default = 0x04)
Bit
[0]
Name
STRT 1, 2
R/W
R/W
[1]
LOCK
Write once
[2]
RDY
Read-only
[3]
FSPD
R/W
[4]
Vx1
R/W
[5]
FSPDIS
R/W
[6]
TODIS
R/W
1
2
T
Description
Logic 1 enables monitoring and PWM control outputs based on the limit settings programmed.
Logic 0 disables monitoring and PWM control based on the default power-up limit settings.
Note that the limit values programmed are preserved even if a Logic 0 is written to this bit and the
default settings are enabled. This bit does not become locked once Bit 1 (LOCK bit) has been set.
Logic 1 locks all limit values to their current settings. Once this bit is set, all lockable registers become
read-only and cannot be modified until the ADT7476 is powered down and powered up again. This
prevents rogue programs such as viruses from modifying critical system limit settings. (This bit is
lockable.)
This bit is set to 1 by the ADT7476 to indicate only that the device is fully powered up and ready to begin
system monitoring.
When set to 1, this bit runs all fans at maximum speed as programmed in the maximum PWM duty cycle
registers (0x30 to 0x32). Power-on default = 0. This bit is not locked at any time.
BIOS should set this bit to a 1 when the ADT7476 is configured to measure current from an ADI ADOPT™
VRM controller and to measure the CPU’s core voltage. This bit allows monitoring software to display
CPU watts usage. (This bit is lockable.)
Logic 1 disables fan spin-up for two TACH pulses. Instead, the PWM outputs go high for the entire fan
spin-up timeout selected.
When this bit is set to 1, the SMBus timeout feature is enabled.
In this state, if at any point during an SMBus transaction involving the ADT7476 activity ceases for more
than 35 ms, the ADT7476 assumes the bus is locked and releases the bus. This allows the ADT7476 to be
used with SMBus controllers that cannot handle SMBus timeouts. (This bit is lockable.)
Bit 0 (STRT) of Configuration Register 1 (0x40) remains writable after lock bit is set.
When monitoring (STRT) is disabled, PWM outputs always go to 100% for thermal protection.
Table 27. Register 0x41—Interrupt Status Register 1 (Power-On Default = 0x00)
Bit
[0]
R/W
Read-only
[1]
Name
2.5 V/
THERM
timer
VCCP
[2]
VCC
Read-only
[3]
5V
Read-only
[4]
R1T
Read-only
[5]
LT
Read-only
Read-only
Description
2.5 V = 1 indicates that the 2.5 V high or low limit has been exceeded. This bit is cleared on a read of the
status register only if the error condition has subsided. If Pin 22 is configured as THERM, this bit is
asserted when the timer limit has been exceeded.
VCCP = 1 indicates that the VCCP high or low limit has been exceeded. This bit is cleared on a read of the
status register only if the error condition has subsided.
VCC = 1 indicates that the VCC high or low limit has been exceeded. This bit is cleared on a read of the
status register only if the error condition has subsided.
A 1 indicates the 5 V high or low limit has been exceeded. This bit is cleared on a read of the status
register only if the error condition has subsided.
R1T = 1 indicates that the Remote 1 low or high temperature has been exceeded. This bit is cleared on a
read of the status register only if the error condition has subsided.
LT = 1 indicates that the local low or high temperature has been exceeded. This bit is cleared on a read of
the status register only if the error condition has subsided.
Rev. A | Page 58 of 72
ADT7476
Bit
[6]
Name
R2T
R/W
Read-only
[7]
OOL
Read-only
Description
R2T = 1 indicates that the Remote 2 low or high temperature has been exceeded. This bit is cleared on a
read of the status register only if the error condition has subsided.
OOL = 1 indicates that an out-of-limit event has been latched in Interrupt Status Register 2. This bit is a
logical OR of all status bits in Interrupt Status Register 2. Software can test this bit in isolation to
determine whether any of the voltage, temperature, or fan speed readings represented by Interrupt
Status Register 2 are out-of-limit, which saves the need to read Interrupt Status Register 2 during every
interrupt or polling cycle.
OOL = 0, then when one or more alerts are generated in Interrupt Status Register 2, assuming all the
mask bits in the Interrupt Mask Register 2 (0x75) =1, SMBALERT is still asserted.
OOL = 1, then when one or more alerts are generated in Interrupt Status Register 2, assuming all the
mask bits in the Interrupt Mask Register 2 (0x75) =1, SMBALERT is not asserted.
Table 28. Register 0x42—Interrupt Status Register 2 (Power-On Default = 0x00)
Bit
[0]
Name
12V/VC
R/W
Read-only
Description
A 1 indicates that the 12 V high or low limit has been exceeded. This bit is cleared on a read of the status
register only if the error condition has subsided. If Pin 21 is configured as VID5, this bit is the VID change bit.
This bit is set when the levels on VID0 to VID5 are different than they were 11 μs previously. This pin can be
used to generate an SMBALERT whenever the VID code changes.
[1]
OVT
Read-only
OVT = 1 indicates that one of the THERM overtemperature limits has been exceeded. This bit is cleared on a
read of the status register when the temperature drops below THERM − THYST.
[2]
FAN1
Read-only
[3]
FAN2
Read-only
[4]
FAN3
Read-only
[5]
F4P
Read-only
FAN1 = 1 indicates that Fan 1 has dropped below minimum speed or has stalled. This bit is not set when
the PWM 1 output is off.
FAN2 = 1 indicates that Fan 2 has dropped below minimum speed or has stalled. This bit is not set when
the PWM 2 output is off.
FAN3 = 1 indicates that Fan 3 has dropped below minimum speed or has stalled. This bit is not set when
the PWM 3 output is off.
When Pin 14 is programmed as a TACH4 input, F4P = 1 indicates that Fan 4 has dropped below minimum
speed or has stalled. This bit is not set when the PWM3 output is off.
When Pin 14 is programmed as the GPIO6 output, writing to this bit determines the logic output of GPIO6.
When GPIO6 is programmed as an input, this bit reflects the value read by GPIO6.
If Pin 14 is configured as the THERM timer input for THERM monitoring, then this bit is set when the THERM
assertion time exceeds the limit programmed in the THERM limit register (Reg. 0x7A).
R/W
Read-only
[6]
[7]
D1
D2
Read-only
Read-only
D1 = 1 indicates either an open or short circuit on the Thermal Diode 1 inputs.
D2 = 1 indicates either an open or short circuit on the Thermal Diode 2 inputs.
Table 29. Register 43H—VID Register (Power-On Default = 0x1F )
Bit
[4:0]
Name
VID/GPIO
R/W
Readonly
[5]
VID5/GPIO
[6]
THLD
Readonly
R/W
[7]
VIDSEL
R/W
Description
The VID inputs from the CPU indicate the expected processor core voltage. On power-up, these bits
reflect the state of the VID pins, even if monitoring is not enabled.
When enabled as a GPO, these bits are writable.
Reads VID5 from the CPU when Bit 7 = 1. If Bit 7 = 0, the VID5 bit always reads back 0 (power-on default).
When enabled as a GPO, this bit is writable.
Selects the input switching threshold for the VID inputs.
THLD = 0 selects a threshold of 1 V (VOL < 0.8 V, VIH > 1.7 V).
THLD = 1 lowers the switching threshold to 0.6 V (VOL < 0.4 V, VIH > 0.8 V).
VIDSEL = 0 configures Pin 21 as the 12 V measurement input (default).
Rev. A | Page 59 of 72
ADT7476
Table 30. Voltage Limit Registers 1
Register Address
0x44
0x45
0x46
0x47
0x48
0x49
0x4A
0x4B
0x4C
0x4D
1
2
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Description 2
2.5 V low limit
2.5 V high limit
VCCP low limit
VCCP high limit
VCC low limit
VCC high limit
5 V low limit
5 V high limit
12 V low limit
12 V high limit
Power-On Default
0x00
0xFF
0x00
0xFF
0x00
0xFF
0x00
0xFF
0x00
0xFF
Setting the Configuration Register 1 lock bit has no effect on these registers.
High limits: An interrupt is generated when a value exceeds its high limit (>comparison). Low limits: An interrupt is generated when a value is equal to or below its low
limit (≤comparison).
Table 31. Temperature Limit Registers 1
Register Address
0x4E
R/W
R/W
Description 2
Remote 1 temperature low limit
Power-On Default
0x81
0x4F
0x50
0x51
0x52
0x53
R/W
R/W
R/W
R/W
R/W
Remote 1 temperature high limit
Local temperature low limit
Local temperature high limit
Remote 2 temperature low limit
Remote 2 temperature high limit
0x7F
0x81
0x7F
0x81
0x7F
1
2
Exceeding any of these temperature limits by 1°C causes the appropriate status bit to be set in the interrupt status register. Setting the Configuration Register 1 lock
bit has no effect on these registers.
High limits: An interrupt is generated when a value exceeds its high limit (>comparison). Low limits: An interrupt is generated when a value is equal to or below its low
limit (≤comparison).
Table 32. Fan Tachometer Limit Registers 1
Register Address
0x54
0x55
R/W
R/W
R/W
0x56
0x57
0x58
0x59
0x5A
0x5B
R/W
R/W
R/W
R/W
R/W
R/W
1
Description
TACH1 minimum low byte
TACH1 minimum high byte/single-channel ADC
channel select
TACH2 minimum low byte
TACH2 minimum high byte
TACH3 minimum low byte
TACH3 minimum high byte
TACH4 minimum low byte
TACH4 minimum high byte
Power-On Default
0xFF
0xFF
0xFF
0xFF
0xFF
0xFF
0xFF
0xFF
Exceeding any of the TACH limit registers by 1 indicates that the fan is running too slowly or has stalled. The appropriate status bit is set in Interrupt Status Register 2
to indicate the fan failure. Setting the Configuration Register 1 lock bit has no effect on these registers.
Table 33. Register 0x55—TACH 1 Minimum High Byte (Power-On Default = 0xFF)
Bits
[4:0]
Name
Reserved
R/W
Read-only
[7:5]
SCADC
R/W
Description
These bits are reserved when Bit 6 of Configuration Register 2 (0x73) is set (single-channel ADC mode).
Otherwise, these bits represent Bits [4:0] of the TACH1 minimum high byte.
When Bit 6 of Configuration Register 2 (0x73) is set (single-channel ADC mode), these bits are used to
select the only channel from which the ADC takes measurements. Otherwise, these bits represent Bits
[7:5] of the TACH1 minimum high byte.
Rev. A | Page 60 of 72
ADT7476
Table 34. PWM Configuration Registers
R/W 1
R/W
R/W
R/W
Register Address
0x5C
0x5D
0x5E
1
Description
PWM1 configuration
PWM2 configuration
PWM3 configuration
Power-On Default
0x62
0x62
0x62
These registers become read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to these registers fail.
Table 35. Register 0x5C, Register 0x5D, and Register 0x5E—PWM Configuration Registers (Power-On Default = 0x62)
Bit
[2:0]
Name
SPIN
R/W
R/W
[4]
INV
R/W
[7:5]
BHVR
R/W
Description
These bits control the startup timeout for PWMx. The PWM output stays high until two valid
TACH rising edges are seen from the fan. If there is not a valid TACH signal during the fan TACH
measurement directly after the fan startup timeout period, then the TACH measurement reads
0xFFFF and Interrupt Status Register 2 reflects the fan fault. If the TACH minimum high and
low bytes contain 0xFFFF or 0x0000, then the Status Register 2 bit is not set, even if the fan has
not started.
000 = No startup timeout
001 = 100 ms
010 = 250 ms (default)
011 = 400 ms
100 = 667 ms
101 = 1 sec
110 = 2 sec
111 = 4 sec
This bit inverts the PWM output. The default is 0, which corresponds to a logic high output for
100% duty cycle. Setting this bit to 1 inverts the PWM output, so 100% duty cycle corresponds
to a logic low output.
These bits assign each fan to a particular temperature sensor for localized cooling.
000 = Remote 1 temperature controls PWMx (automatic fan control mode).
001 = Local temperature controls PWMx (automatic fan control mode).
010 = Remote 2 temperature controls PWMx (automatic fan control mode).
011 = PWMx runs full speed (default).
100 = PWMx disabled.
101 = Fastest speed calculated by local and Remote 2 temperature controls PWMx.
110 = Fastest speed calculated by all three temperature channel controls PWMx.
111 = Manual mode. PWM duty cycle registers (Register 0x30 to Register 0x32) become
writable.
Rev. A | Page 61 of 72
ADT7476
Table 36. TEMP TRANGE/PWM Frequency Registers
R/W 1
R/W
R/W
R/W
Register Address
0x5F
0x60
0x61
1
Description
Remote 1 TRANGE/PWM1 frequency
Local temperature TRANGE/PWM2 frequency
Remote 2 TRANGE/PWM3 frequency
Power-On Default
0xC4
0xC4
0xC4
These registers become read-only when the Configuration Register 1 lock bit is set. Any subsequent attempts to write to these registers fail.
Table 37. Register 0x5F, Register 0x60, and Register 0x61—TEMP TRANGE/PWM Frequency Registers (Power-On Default = 0xC4)
Bit
[2:0]
Name
FREQ
R/W
R/W
[3]
HF/LF
R/W
[7:4]
RANGE
R/W
Description
These bits control the PWMx frequency (only apply when PWM channel is in low frequency mode).
000 = 11.0 Hz
001 = 14.7 Hz
010 = 22.1 Hz
011 = 29.4 Hz
100 = 35.3 Hz (default)
101 = 44.1 Hz
110 = 58.8 Hz
111 = 88.2 Hz
HF/LF = 1, High frequency PWM mode is enabled for PWMx.
HF/LF = 0, Low frequency PWM mode is enabled for PWMx.
These bits determine the PWM duty cycle vs. the temperature range for automatic fan control.
0000 = 2°C
0001 = 2.5°C
0010 = 3.33°C
0011 = 4°C
0100 = 5°C
0101 = 6.67°C
0110 = 8°C
0111 = 10°C
1000 = 13.33°C
1001 = 16°C
1010 = 20°C
1011 = 26.67°C
1100 = 32°C (Default)
1101 = 40°C
1110 = 53.33°C
1111 = 80°C
Rev. A | Page 62 of 72
ADT7476
Table 38. Register 0x62—Enhanced Acoustics Register 1 (Power-On Default = 0x00)
Bit
[2:0]
Name
ACOU 2
R/W 1
R/W
[3]
[4]
EN1
SYNC
R/W
R/W
[5]
MIN1
R/W
[6]
MIN2
R/W
[7]
MIN3
R/W
1
2
Description
Assuming that PWMx is associated with the Remote 1 temperature channel, these bits define the maximum
rate of change of the PWMx output for Remote 1 temperature-related changes. Instead of the fan speed
jumping instantaneously to its newly determined speed, it ramps gradually at the rate determined by these
bits. This feature ultimately enhances the acoustics of the fan.
When Bit 7 of Configuration Register 6 (0x10) is 0
Time Slot Increase
Time for 0% to 100%
000 = 1
37.5 sec
001 = 2
18.8 sec
010 = 3
12.5 sec
011 = 4
7.5 sec
100 = 8
4.7 sec
101 = 12
3.1 sec
110 = 24
1.6 sec
111 = 48
0.8 sec
When Bit 7 of Configuration Register 6 (0x10) is 1
Time Slot Increase
Time for 0% to 100%
000 = 1
52.2 sec
001 = 2
26.1 sec
010 = 3
17.4 sec
011 = 4
10.4 sec
100 = 8
6.5 sec
101 = 12
4.4 sec
110 = 24
2.2 sec
111 = 48
1.1 sec
When this bit is 1, smoothing is enabled on Remote 1 temperature channel.
SYNC = 1 synchronizes fan speed measurements on TACH2, TACH3, and TACH4 to PWM3. This allows up to
three fans to be driven from PWM3 output and their speeds to be measured.
SYNC = 0 synchronizes only TACH3 and TACH4 to PWM3 output.
When the ADT7476 is in automatic fan control mode, this bit defines whether PWM1 is off (0% duty cycle)
or at PWM1 minimum duty cycle when the controlling temperature is below its TMIN – hysteresis value.
0 = 0% duty cycle below TMIN – hysteresis.
1 = PWM1 minimum duty cycle below TMIN – hysteresis.
When the ADT7476 is in automatic fan speed control mode, this bit defines whether PWM2 is off (0% duty
cycle) or at PWM2 minimum duty cycle when the controlling temperature is below its TMIN – hysteresis
value.
0 = 0% duty cycle below TMIN – hysteresis.
1 = PWM2 minimum duty cycle below TMIN – hysteresis.
When the ADT7476 is in automatic fan speed control mode, this bit defines whether PWM3 is off (0% duty
cycle) or at PWM3 minimum duty cycle when the controlling temperature is below its TMIN – hysteresis
value.
0 = 0% duty cycle below TMIN – hysteresis.
1 = PWM3 minimum duty cycle below TMIN – hysteresis.
This register becomes read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Setting the relevant bit of Configuration Register 6 (0x10, Bits [2:0]), further decreases these ramp rates by a factor of 4.
Rev. A | Page 63 of 72
ADT7476
Table 39. Register 0x63—Enhanced Acoustics Register 2 (Power-On Default = 0x00)
Bit
[2:0]
Name
ACOU3
R/W 1
R/W
[3]
[6:4]
EN3
ACOU2
R/W
R/W
[7]
EN2
Read/write
1
Description
Assuming that PWMx is associated with the Local temperature channel, these bits define the maximum
rate of change of the PWMx output for local temperature-related changes. Instead of the fan speed
jumping instantaneously to its newly determined speed, it ramps gradually at the rate determined by
these bits. This feature ultimately enhances the acoustics of the fan.
When Bit 7 of Configuration Register 6 (0x10) is 0
Time Slot Increase
Time for 0% to 100%
000 = 1
37.5 sec
001 = 2
18.8 sec
010 = 3
12.5 sec
011 = 4
7.5 sec
100 = 8
4.7 sec
101 = 12
3.1 sec
110 = 24
1.6 sec
111 = 48
0.8 sec
When Bit 7 of Configuration Register 6 (0x10) is 1
Time Slot Increase
Time for 0% to 100%
000 = 1
52.2 sec
001 = 2
26.1 sec
010 = 3
17.4 sec
011 = 4
10.4 sec
100 = 8
6.5 sec
101 = 12
4.4 sec
110 = 24
2.2 sec
111 = 48
1.1 sec
When this bit is 1, smoothing is enabled on the local temperature channel.
Assuming that PWMx is associated with the Remote 2 temperature channel, these bits define the
maximum rate of change of the PWMx output for Remote 2 temperature related changes. Instead of
the fan speed jumping instantaneously to its newly determined speed, it ramps gradually at the rate
determined by these bits. This feature ultimately enhances the acoustics of the fan.
When Bit 7 of Configuration Register 6 (0x10) is 0
Time Slot Increase
Time for 0% to 100%
000 = 1
37.5 sec
001 = 2
18.8 sec
010 = 3
12.5 sec
011 = 4
7.5 sec
100 = 8
4.7 sec
101 = 12
3.1 sec
110 = 24
1.6 sec
111 = 48
0.8 sec
When Bit 7 of Configuration Register 6 (0x10) is 1
Time Slot Increase
Time for 0% to 100%
000 = 1
52.2 sec
001 = 2
26.1 sec
010 = 3
17.4 sec
011 = 4
10.4 sec
100 = 8
6.5 sec
101 = 12
4.4 sec
110 = 24
2.2 sec
111 = 48
1.1 sec
When this bit is 1, smoothing is enabled on the Remote 2 temperature channel.
This register becomes read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Rev. A | Page 64 of 72
ADT7476
Table 40. PWM Minimum Duty Cycle Registers
R/W 1
R/W
R/W
R/W
Register Address
0x64
0x65
0x66
1
Description
PWM1 minimum duty cycle
PWM2 minimum duty cycle
PWM3 minimum duty cycle
Power-On Default
0x80 (50% duty cycle)
0x80 (50% duty cycle)
0x80 (50% duty cycle)
These registers become read-only when the ADT7476 is in automatic fan control mode.
Table 41. Register 0x64, Register 0x65, Register 0x66—PWM Minimum Duty Cycle Registers (Power-On Default = 0x80;
50% duty cycle)
Bit
[7:0]
1
Name
PWM duty cycle
R/W 1
R/W
Description
These bits define the PWMMIN duty cycle for PWMx.
0x00 = 0% duty cycle (fan off ).
0x40 = 25% duty cycle.
0x80 = 50% duty cycle.
0xFF = 100% duty cycle (fan full speed).
These registers become read-only when the ADT7476 is in automatic fan control mode.
Table 42. TMIN Registers 1
Register Address
0x67
0x68
0x69
R/W 2
R/W
R/W
R/W
Description
Remote 1 temperature TMIN
Local temperatue TMIN
Remote 2 temperature TMIN
Power-On Default
0x5A (90°C)
0x5A (90°C)
0x5A (90°C)
1
These are the TMIN registers for each temperature channel. When the temperature measured exceeds TMIN, the appropriate fan runs at minimum speed and increases
with temperature according to TRANGE.
2
These registers become read-only when the Configuration Register 1 lock bit is set. Any subsequent attempts to write to these registers fail.
Table 43. THERM Limit Registers 1
R/W 2
R/W
Description
Remote 1 THERM limit
Power-On Default
0x64 (100°C)
0x6B
R/W
Local THERM limit
0x64 (100°C)
0x6C
R/W
Remote 2 THERM limit
0x64 (100°C)
Register Address
0x6A
If any temperature measured exceeds its THERM limit, all PWM outputs drive their fans at 100% duty cycle. This is a fail-safe mechanism incorporated to cool the
system in the event of a critical overtemperature. It also ensures some level of cooling in the event that software or hardware locks up. If set to 0x80, this feature is
disabled. The PWM output remains at 100% until the temperature drops below THERM limit – hysteresis. If the THERM pin is programmed as an output, exceeding
these limits by 0.25°C can cause the THERM pin to assert low as an output.
2
These registers become read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to these registers fail.
1
Table 44. Temperature/TMIN Hysteresis Registers 1
Register Address
0x6D
Bit Name
R/W 2
R/W
HYSL [3:0]
HYSR1 [7:4]
0x6E
R/W
HYSR2 [7:4]
Description
Remote 1 and Local Temperature hysteresis.
Local Temperature hysteresis. 0°C to 15°C of
hysteresis can be applied to the Local
temperature AFC control loops.
Remote 1 Temperature hysteresis. 0°C to
15°C of hysteresis can be applied to the
Remote 1 Temperature AFC control loops.
Remote 2 temperature hysteresis.
Local Temperature hysteresis. 0°C to 15°C of
hysteresis can be applied to the Local
Temperature AFC control loops.
1
Power-On Default
0x44
0x40
Each 4-bit value controls the amount of temperature hysteresis applied to a particular temperature channel. Once the temperature for that channel falls below its
TMIN value, the fan remains running at PWMMIN duty cycle until the temperature = TMIN – hysteresis. Up to 15°C of hysteresis can be assigned to any temperature
channel. The hysteresis value chosen also applies to that temperature channel, if its THERM limit is exceeded. The PWM output being controlled goes to 100%, if the
THERM limit is exceeded and remains at 100% until the temperature drops below THERM – hysteresis. For acoustic reasons, it is recommended the hysteresis value not
be programmed less than 4°C. Setting the hysteresis value lower than 4°C causes the fan to switch on and off regularly when the temperature is close to TMIN.
2
These registers become read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to these registers fail.
Rev. A | Page 65 of 72
ADT7476
Table 45. XNOR Tree Test Enable
Register Address
0x6F
Bit Name
R/W 1
R/W
XEN [0]
Reserved [7:1]
1
Description
XNOR tree test enable register.
If the XEN bit is set to 1, the device enters
the XNOR tree test mode. Clearing the bit
removes the device from the XNOR tree test
mode.
Unused. Do not write to these bits.
Power-On Default
0x00
This register becomes read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Table 46. Remote 1 Temperature Offset
Register Address
0x70
1
Bit
[7:0]
R/W 1
R/W
Description
Remote 1 temperature offset.
Allows a temperature offset to be applied
automatically to the Remote 1 temperature
channel measurement. Bit 1 of
Configuration Register 5 (0x7C) determines
the range and resolution of this register.
Power-On Default
0x00
This register becomes read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Table 47. Local Temperature Offset
Register Address
0x71
1
Bit
[7:0]
R/W 1
R/W
Description
Local temperature offset.
Allows a temperature offset to be applied
automatically to the local temperature
measurement. Bit 1 of Configuration
Register 5 (0x7C) determines the range and
resolution of this register.
Power-On Default
0x00
This register becomes read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Table 48. Remote 2 Temperature Offset
Register Address
0x72
1
Bit
[7:0]
R/W 1
R/W
Description
Remote 2 temperature offset.
Allows a temperature offset to be applied
automatically to the Remote 2 temperature
channel measurement. Bit 1 of
Configuration Register 5 (0x7C) determines
the range and resolution of this register.
Power-On Default
0x00
This register becomes read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Rev. A | Page 66 of 72
ADT7476
Table 49. Register 0x73—Configuration Register 2 (Power-On Default = 0x00)
Bit
[0]
Name
FanPresenceDT
R/W 1
R/W
[1]
[2]
[3]
[4]
Fan1Detect
Fan2Detect
Fan3Detect
AVG
Read
Read
Read
R/W
[5]
ATTN
R/W
[6]
CONV
R/W
[7]
Res
1
Description
When FanPresenceDT = 1, the state of Bits [3:1] of 0x73 reflects the presence of a 4-wire fan on
the appropriate TACH channel.
Fan1Detect = 1 indicates that a 4-wire fan is connected to the TACH 1 input.
Fan2Detect = 1 indicates that a 4-wire fan is connected to the TACH 2 input.
Fan3Detect = 1 indicates that a 4-wire fan is connected to the TACH 3 input.
AVG = 1, averaging on the temperature and voltage measurements is turned off. This allows
measurements on each channel to be made much faster (x16).
ATTN = 1, the ADT7476 removes the attenuators from the 2.5 V, VCCP, 5 V, and 12 V inputs. These
inputs can be used for other functions such as connecting up external sensors. It is also possible
to remove attenuators from individual channels using Bits [7:4] of Configuration Register 4
(0x7D).
CONV = 1, the ADT7476 is put into a single-channel ADC conversion mode. In this mode, the
ADT7476 can be made to read continuously from one input only, for example, Remote 1
temperature. The appropriate ADC channel is selected by writing to Bits [7:5] of TACH 1
minimum high byte register (0x55).
Register 0x55, Bits [7:5]
000
2.5 V
001
VCCP
010
VCC (3.3 V)
011
5V
100
12 V
101
Remote 1 temperature
110
Local temperature
111
Remote 2 temperature
This bit is reserved and should not be changed.
This register becomes read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Table 50. Register 0x74—Interrupt Mask Register 1 (Power-On Default <7:0> = 0x00)
Bit
[0]
Name
2.5V/ THERM
R/W
R/W
Description
2.5V/ THERM = 1, masks SMBALERT for out-of-limit conditions on the 2.5 V/ THERM timer channel.
[1]
VCCP
R/W
VCCP = 1, masks SMBALERT for out-of-limit conditions on the VCCP channel.
[2]
VCC
R/W
VCC = 1, masks SMBALERT for out-of-limit conditions on the VCC channel.
[3]
5V
R/W
5 V = 1, masks SMBALERT for out-of-limit conditions on the 5 V channel.
[4]
RIT
R/W
RIT = 1, masks SMBALERT for out-of-limit conditions on the Remote 1 temperature channel.
[5]
LT
R/W
LT = 1, masks SMBALERT for out-of-limit conditions on the local temperature channel.
[6]
R2T
R/W
R2T = 1, masks SMBALERT for out-of-limit conditions on the Remote 2 temperature channel.
[7]
OOL
R/W
OOL = 1, masks SMBALERT for any out-of-limit condition in Interrupt Status Register 2.
Rev. A | Page 67 of 72
ADT7476
Table 51. Register 0x75—Interrupt Mask Register 2 (Power-On Default <7:0> = 0x00)
Bit
[0]
Name
12V/VC
R/W
R/W
[1]
OVT
Read only
Description
When Pin 21 is configured as a 12 V input, 12V/VC = 1 masks SMBALERT for out-of-limit conditions
on the 12 V channel. When Pin 21 is programmed as VID5, this bit masks an SMBALERT, if the VID5
VID code bit changes.
OVT = 1, masks SMBALERT for overtemperature THERM conditions.
[2]
FAN1
R/W
FAN1 = 1, masks SMBALERT for a Fan 1 fault.
[3]
FAN2
R/W
FAN2 = 1, masks SMBALERT for a Fan 2 fault.
[4]
FAN3
R/W
FAN3 = 1, masks SMBALERT for a Fan 3 fault.
[5]
F4P
R/W
[6]
D1
R/W
If Pin 14 is configured as TACH 4, F4P = 1 masks SMBALERT for a Fan 4 fault.
If Pin 14 is configured as THERM, F4P = 1 masks SMBALERT for an exceeded THERM timer limit.
If Pin 14 is configured as GPIO, F4P = 1 masks SMBALERT when GPIO is an input and GPIO is
asserted.
D1 = 1 masks SMBALERT for a diode open or short on a Remote 1 channel.
[7]
D2
R/W
D2 = 1 masks SMBALERT for a diode open or short on a Remote 2 channel.
Table 52. Register 0x76—Extended Resolution Register 1 1 (Power-On Default <7:0> = 0x00)
Bit
[1:0]
[3:2]
[5:4]
[7:6]
1
Name
2.5 V
VCCP
VCC
5V
R/W
Read-only
Read-only
Read-only
Read-only
Description
2.5 V LSBs. Holds the 2 LSBs of the 10-bit 2.5 V measurement.
VCCP LSBs. Holds the 2 LSBs of the 10-bit VCCP measurement.
VCC LSBs. Holds the 2 LSBs of the 10-bit VCC measurement.
5 V LSBs. Holds the 2 LSBs of the 10-bit 5 V measurement.
If this register is read, this register and the registers holding the MSB of each reading are frozen until read.
Table 53. Register 0x77—Extended Resolution Register 2 1 (Power-On Default <7:0> = 0x00)
Bit
[1:0]
[3:2]
[5:4]
[7:6]
1
Name
12 V
TDM1
LTMP
TDM2
R/W
Read-only
Read-only
Read-only
Read-only
Description
12 V LSBs. Holds the 2 LSBs of the 10-bit 12 V measurement.
Remote 1 Temperature LSBs. Holds the 2 LSBs of the 10-bit Remote 1 temperature measurement.
Local Temperature LSBs. Holds the 2 LSBs of the 10-bit local temperature measurement.
Remote 2 Temperature LSBs. Holds the 2 LSBs of the 10-bit Remote 2 temperature measurement.
If this register is read, this register and the registers holding the MSB of each reading are frozen until read.
Rev. A | Page 68 of 72
ADT7476
Table 54. Register 0x78—Configuration Register 3 (Power-On Default = 0x00)
Bit
[0]
Name
ALERT
R/W 1
R/W
Description
ALERT = 1, Pin 10 (PWM2/SMBALERT) is configured as an SMBALERT interrupt output to indicate
out-of-limit error conditions.
ALERT = 0, Pin 10 (PWM2/SMBALERT) is configured as the PWM2 output.
[1]
THERM/
2.5 V
R/W
THERM = 1 enables THERM functionality on Pin 22 and Pin 14, if Pin 14 is configured as THERM,
determined by Bits 0 and 1 (PIN14FUNC) of Configuration Register 4. When THERM is asserted, if
the fans are running and the boost bit is set, the fans run at full speed. Alternatively, THERM can be
programmed so that a timer is triggered to time how long THERM has been asserted.
THERM = 0 enables 2.5V measurement on Pin 22 and disables THERM. If Bits [7:5] of Configuration
Register 5 are set, THERM is bidirectional. If they are 0, THERM is a timer input only.
[2]
BOOST
R/W
[3]
FAST
R/W
[4]
DC1
R/W
[5]
DC2
R/W
[6]
DC3
R/W
[7]
DC4
R/W
1
Pin14FUNC
THERM/2.5 V
Pin 22
Pin 14
00
01
10
11
00
01
10
11
0
0
0
0
1
1
1
1
2.5 V
2.5 V
2.5 V
2.5 V
THERM
2.5 V
THERM
THERM
TACH4
THERM
SMBALERT
GPIO
TACH4
THERM
SMBALERT
GPIO
When THERM is an input and BOOST = 1, assertion of THERM causes all fans to run at the maximum
programmed duty cycle for fail-safe cooling.
FAST = 1, enables fast TACH measurements on all channels. This increases the TACH measurement
rate from once per second to once every 250 ms (4 ×).
DC1 = 1, enables TACH measurements to be continuously made on TACH1. Fans must be driven by
dc. Setting this bit prevents pulse stretching because it is not required for dc-driven motors.
DC2 = 1, enables TACH measurements to be continuously made on TACH2. Fans must be driven by
dc. Setting this bit prevents pulse stretching because it is not required for dc-driven motors.
DC3 = 1, enables TACH measurements to be continuously made on TACH3. Setting this bit prevents
pulse stretching because it is not required for dc-driven motors.
DC4 = 1, enables TACH measurements to be continuously made on TACH4. Setting this bit prevents
pulse stretching because it is not required for dc-driven motors.
This register becomes read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Table 55. Register 0x79—THERM Timer Status Register (Power-On Default = 0x00)
Bit
[7:1]
Name
TMR
R/W
Read-only
[0]
ASRT/
TMR0
Read-only
Description
Times how long THERM input is asserted. These seven bits read zero until the THERM assertion time
exceeds 45.52 ms.
This bit is set high on the assertion of the THERM input and is cleared on read. If the THERM
assertion time exceeds 45.52 ms, this bit is set and becomes the LSB of the 8-bit TMR reading. This
allows THERM assertion times from 45.52 ms to 5.82 sec to be reported back with a resolution of
22.76 ms.
Table 56. Register 0x7A—THERM Timer Limit Register (Power-On Default = 0x00)
Bit
[7:0]
Name
LIMT
R/W
R/W
Description
Sets maximum THERM assertion length allowed before an interrupt is generated. This is an 8-bit limit
with a resolution of 22.76 ms allowing THERM assertion limits of 45.52 ms to 5.82 sec to be
programmed. If the THERM assertion time exceeds this limit, Bit 5 (F4P) of Interrupt Status Register 2
(Reg. 0x42) is set. If the limit value is 0x00, an interrupt is generated immediately on the assertion of
the THERM input.
Rev. A | Page 69 of 72
ADT7476
Table 57. Register 0x7B—TACH Pulses per Revolution Register (Power-On Default = 0x55)
Bit
[1:0]
Name
FAN1
R/W
R/W
[3:2]
FAN2
R/W
[5:4]
FAN3
R/W
[7:6]
FAN4
R/W
Description
Sets number of pulses to be counted when measuring Fan 1 speed. Can be used to determine fan
pulses per revolution for unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
Sets number of pulses to be counted when measuring Fan 2 speed. Can be used to determine fan
pulses per revolution for unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
Sets number of pulses to be counted when measuring Fan 3 speed. Can be used to determine fan
pulses per revolution for unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
Sets number of pulses to be counted when measuring Fan 4 speed. Can be used to determine fan
pulses per revolution for unknown fan type.
Pulses Counted
00 = 1
01 = 2 (default)
10 = 3
11 = 4
Table 58. Register 0x7C—Configuration Register 5 (Power-On Default = 0x01)
Bit
[0]
Name
TWOS
COMPL
R/W 1
R/W
[1]
TempOffset
R/W
[2]
GPIO6D
R/W
[3]
GPIO6P
R/W
[4]
VID/GPIO
R/W
[5]
R1 THERM
R/W
Description
TWOS COMPL = 1, sets the temperature range to the twos complement temperature range.
TWOS COMPL = 0, changes the temperature range to the Offset 64 temperature range. When this bit
is changed, the ADT7476 interprets all relevant temperature register values as defined by this bit.
TempOffset = 0, sets offset range to −63°C to +64°C with 0.5°C resolution.
TempOffset = 1, sets offset range to −63°C to +127°C with 1°C resolution.
These settings apply to registers 0x70, 0x71 and 0x72 (Remote 1, internal, and Remote 2 temperature
offset registers.
GPIO 6 direction. When GPIO 6 function is enabled, this determines whether GPIO 6 is an input (0) or
an output (1).
GPIO 6 polarity. When the GPIO 6 function is enabled and is programmed as an output, this bit
determines whether the GPIO 6 is active low (0) or high (1).
VID/GPIO = 0, VID functionality is enabled on Pin 5, Pin 6, Pin 7, Pin 8, and Pin 19.
VID/GPIO = 1, GPIO functionality is enabled on Pin 5, Pin 6, Pin 7, Pin 8, and Pin 19.
R1 THERM = 1 , THERM temperature limit functionality enabled for Remote 1 temperature channel,
that is THERM is bidirectional. R1 THERM = 0, THERM is a timer input only.
THERM can also be disabled on any channel by:
In Offset 64 mode, writing −64°C to the appropriate THERM temperature limit
In twos complement mode, writing −128°C to the appropriate THERM temperature limit
Rev. A | Page 70 of 72
ADT7476
Bit
[6]
Name
Local
THERM
R/W 1
R/W
Description
Local THERM = 1 , THERM temperature limit functionality enabled for local temperature channel, that
is THERM is bidirectional. Local THERM = 0, THERM is a timer input only.
THERM can also be disabled on any channel by:
In Offset 64 mode, writing −64°C to the appropriate THERM temperature limit
In twos complement mode, writing −128°C to the appropriate THERM temperature limit
[7]
R2 THERM
R/W
R2 THERM = 1 , THERM temperature limit functionality enabled for Remote 2 temperature channel,
that is. THERM is bidirectional. R2 THERM = 0, THERM is a timer input only.
THERM can also be disabled on any channel by:
In Offset 64 mode, writing −64°C to the appropriate THERM temperature limit
In twos complement mode, writing −128°C to the appropriate THERM temperature limit
1
This register becomes read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Table 59. Register 0x7D—Configuration Register 4 (Power-On Default = 0x00)
Bit
[1:0]
Name
PIN14FUNC
R/W 1
R/W
[2]
THERM
Disable
R/W
[3]
MaxSpeed
on THERM
R/W
[4]
BpAtt2.5V
R/W
[5]
BpAttVCCP
R/W
[6]
BpAtt5V
R/W
[7]
BpAtt12V
R/W
1
Description
These bits set the functionality of Pin 14:
00 = TACH4 (default)
01 = THERM
10 = SMBALERT
11 = GPIO
THERM Disable=0, THERM overtemperature output is enabled assuming THERM is correctly
configured (Registers 0x78, 0x7C, 0x7D).
THERM Disable=1, THERM overtemperature output is disabled on all channels.
THERM can also be disabled on any channel by:
In Offset 64 mode, writing −64°C to the appropriate THERM temperature limit.
In twos complement mode, writing −128°C to the appropriate THERM temperature limit.
MaxSpeed on THERM = 0, fans go to full speed when THERM temperature limit is exceeded.
MaxSpeed on THERM = 1, fans go to maximum speed (Registers 0x38, 0x39, and 0x3A) when THERM
temperature limit is exceeded.
Bypass 2.5 V attenuator. When set, the measurement scale for this channel changes from 0 V (0x00) to
2.25 V (0xFF).
Bypass VCCP attenuator. When set, the measurement scale for this channel changes from 0 V (0x00) to
2.25 V (0xFF).
Bypass 5 V attenuator. When set, the measurement scale for this channel changes from 0 V (0x00) to
2.25 V (0xFF).
Bypass 12 V attenuator. When set, the measurement scale for this channel changes from 0 V (0x00) to
2.25 V (0xFF).
This register becomes read-only when the Configuration Register 1 lock bit is set to 1. Any subsequent attempts to write to this register fail.
Table 60. Register 0x7E—Manufacturer’s Test Register 1 (Power-On Default = 0x00)
Bit
[7:0]
Name
Reserved
R/W
Read-only
Description
Manufacturer’s test register. These bits are reserved for manufacturer’s test purposes and should not
be written to under normal operation.
Table 61. Register 0x7F—Manufacturer’s Test Register 2 (Power-On Default = 0x00)
Bit
[7:0]
Name
Reserved
R/W
Read-only
Description
Manufacturer’s test register. These bits are reserved for manufacturer’s test purposes and should not
be written to under normal operation.
Rev. A | Page 71 of 72
ADT7476
OUTLINE DIMENSIONS
0.345
0.341
0.337
24
13
1
0.158
0.154
0.150
12
0.244
0.236
0.228
PIN 1
0.069
0.053
0.065
0.049
0.010
0.004
0.025
BSC
0.012
0.008
COPLANARITY
0.004
SEATING
PLANE
0.010
0.006
8°
0°
0.050
0.016
COMPLIANT TO JEDEC STANDARDS MO-137AE
Figure 67. 24-Lead Shrink Small Outline Package [QSOP]
(RQ-24)
Dimensions shown in inches
ORDERING GUIDE
Model
ADT7476ARQZ 1
ADT7476ARQZ-REEL1
ADT7476ARQZ-REEL7
EVAL-ADT7476EB
1
Termperature Range
–40°C to +125°C
–40°C to +125°C
–40°C to +125°C
Package Description
24-Lead QSOP
24-Lead QSOP
24-Lead QSOP
Evaluation Board
Package Option
RQ-24
RQ-24
RQ-24
Z = Pb-free part.
©2006 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D05382-0-3/06(A)
T
T
Rev. A | Page 72 of 72