EXTECH CA899

2000A AC/DC Clamp Meter
Full range multimeter functions
With high resolution to 0.1μA/0.1mV and CAT IV-600V Safety Rating
380926 Features:
• Full function autoranging DMM includes
AC/DC Voltage and Current, Resistance, Capacitance,
Frequency, Duty Cycle, Diode and Continuity
• Current measurements to 2000A through
the clamp and 400mA via test leads
• Large 4000 count backlit display for high resolution
and easy viewing in dimly lit areas
• Basic DCV accuracy of 1% with 0.1mV resolution
and current resolution to 0.1μA
• Rugged 2" (50mm) jaws accomodate
one 2000MCM or two 500MCM cables
• Features include DCA push button zero,
Relative measurements and Data Hold
• Heavy duty ABS case with built-in stand
and thumb control function switch
• Complete with test leads and 9V battery
Large jaw size for high current measurements
Specifications
DC/AC Current (Clamp):
DC/AC Current (DMM):
DC Voltage:
AC Voltage:
Capacitance:
Resistance:
Frequency:
Duty Cycle:
Diode Check:
Continuity:
Dimensions/Weight:
Ranges
Max. Resolution
400A, 2000A
0.1A
400μA, 4000μA, 40mA, 400mA
0.1μA
400mV, 4.0V, 40V, 400V, 1000V
0.1mV
4V, 40V, 400V, 1000V
1mV
50nF, 500nF, 5.0μF, 50μF
10pF
400Ω, 4.0kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ 0.1Ω
5Hz, 50Hz, 500Hz, 5kHz, 50kHz, 100kHz
0.01Hz
1% to 99%
0.1%
yes
yes
10 x 2.9 x 1.5" (255x73x38mm) / 14oz. (380g)
Basic Accuracy (%rdg+digits)
±(2% + 5d)
±(1.2% + 5d)
±(1% + 2d)
±(1.2% + 5d)
±(3% + 5d)
±(1% + 5d)
±(1% + 5d)
±(1% + 5d)
Ordering Information:
380926 ................2000A True RMS DC/AC Clamp/DMM
380926-NIST ......2000A True RMS DC/AC Clamp/DMM w/NIST Certificate
TL805 ..................Spare Set of CAT. III-1000V Test Leads
CA899..................Large soft case with shoulder strap
www.extech.com
Specifications subject to change without notice.
7/9/09 - R1