CBM100S SERIES 100 WATT AC-DC POWER SUPPLY WITH PFC Features * Universal Input Range 90~264Vac * Full Load with Baseplate Cooled and no fan required * Wide Operating Temperature Range * 17mm Ultra Low Profile Package * Safety Meets EN60950-1 * Built-in EN55022 Class B Filter * Active PFC Meets EN61000-3-2 * High Efficiency Up to 90% Typical * No Load Input Power Consumption <0.5W * Over Temperature Protection * Over Voltage Protection * Over Current Protection MODEL VOLTAGE OUTPUT OUTPUT CURRENT RIPPLE & NOISE NOTE1 VOLTAGE ACCURACY NOTE2 LINE REG. NOTE3 LOAD REG. NOTE4 % EFF. (Typ.) NOTE5 CBM100S120 +12V 8.4A 1.0% ±1.0% ±0.5% ±1% 90% CBM100S240 +24V 4.2A 1.0% ±1.0% ±0.5% ±1% 91% CBM100S280 +28V 3.6A 1.0% ±1.0% ±0.5% ±1% 91% CBM100S360 +36V 2.8A 1.0% ±1.0% ±0.5% ±1% 91% CBM100S480 +48V 2.1A 1.0% ±1.0% ±0.5% ±1% 91.5% 1 Specifications CBM100S Series Derating Curve INPUT SPECIFICATIONS: AC Input Voltage …....…………....…........................................... 90~264Vac Frequency ………………………………………….……………..... 47 to 63Hz Inrush Current ……………….…………....................... 100A max. @240Vac Leakage Current @ 264Vac ……………………………….…..… 3.5mA max. OUTPUT SPECIFICATIONS: Isolation ………………………………………...… Input to output = 4242VDC Total Rated Output Power ……………………………………………… 100W Hold-up Time …………………………………………………….…… 12ms typ. Over Voltage Protection ………………..….…… Recycle AC input to restart Short Circuit Protection …………....... Hiccup mode(Auto Recovery) Over Current Protection …………………….………..….…… Auto Recovery Over Temperature Protection ………………….……..….…… Auto Recovery Temperature Coefficient ……………………….………….……….. ±0.05%/℃ GENERAL SPECIFICATIONS: NOTE: Operating Ambient Temperature ..............…………………...... see derating c u r v e Storage Temperature …………………………...….......……....... -40~100℃ Humidity …………………………...….......….. 93% RH max. Non condensing Switching Frequency .…………...................................... 130KHz Typical 1. CBM100S Series: Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for Ripple &Noise measuring @20MHz BW. 2. Voltage accuracy is set at 60% rated load. 3. Line regulation is measured from High Line to Low Line with rated load. 4. Load regulation is measured at 60%±40% rated. MTBF …...… MIL-HDBK-217F, GB, 25℃/115VAC ….…… 100Khrs min. No Load Input Power Consumption…………...…...………....………..<0.5W Altitude ……………………………………………………………………2000M Dimensions....….4.60x2.40x0.67 Inches (116.80x61.00x17.00mm) W eight ………………………………………..……23 6g (0. 52P o unds) SAFETY AND EMC: Emission and Immunity …….… EN55022 Class B, FCC Part 15 Class B EN61000-6-3, EN61000-3-2, EN61000-3-3 EN55024, EN61000-6-1, EN61204-3 Safety ………………………………..… IEC60950-1, EN60950-1, UL60950-1 Mechanical Specification Typical at 25℃, 230Vac and 75% rated load, unless otherwise Specified 2 5. Typical efficiency with 230Vac and full load at 25℃ 6. Power dissipation (Pd): Pd =Pi-Po=Po(1-η)/η