ETC CBM100S240

CBM100S SERIES
100 WATT AC-DC
POWER SUPPLY
WITH PFC
Features
* Universal Input Range 90~264Vac
* Full Load with Baseplate Cooled and no fan required
* Wide Operating Temperature Range
* 17mm Ultra Low Profile Package
* Safety Meets EN60950-1
* Built-in EN55022 Class B Filter
* Active PFC Meets EN61000-3-2
* High Efficiency Up to 90% Typical
* No Load Input Power Consumption <0.5W
* Over Temperature Protection
* Over Voltage Protection
* Over Current Protection
MODEL
VOLTAGE
OUTPUT
OUTPUT
CURRENT
RIPPLE
& NOISE
NOTE1
VOLTAGE
ACCURACY
NOTE2
LINE
REG.
NOTE3
LOAD
REG.
NOTE4
% EFF.
(Typ.)
NOTE5
CBM100S120
+12V
8.4A
1.0%
±1.0%
±0.5%
±1%
90%
CBM100S240
+24V
4.2A
1.0%
±1.0%
±0.5%
±1%
91%
CBM100S280
+28V
3.6A
1.0%
±1.0%
±0.5%
±1%
91%
CBM100S360
+36V
2.8A
1.0%
±1.0%
±0.5%
±1%
91%
CBM100S480
+48V
2.1A
1.0%
±1.0%
±0.5%
±1%
91.5%
1
Specifications
CBM100S Series Derating Curve
INPUT SPECIFICATIONS:
AC Input Voltage …....…………....…........................................... 90~264Vac
Frequency ………………………………………….……………..... 47 to 63Hz
Inrush Current ……………….…………....................... 100A max. @240Vac
Leakage Current @ 264Vac ……………………………….…..… 3.5mA max.
OUTPUT SPECIFICATIONS:
Isolation ………………………………………...… Input to output = 4242VDC
Total Rated Output Power ……………………………………………… 100W
Hold-up Time …………………………………………………….…… 12ms typ.
Over Voltage Protection ………………..….…… Recycle AC input to restart
Short Circuit Protection …………....... Hiccup mode(Auto Recovery)
Over Current Protection …………………….………..….…… Auto Recovery
Over Temperature Protection ………………….……..….…… Auto Recovery
Temperature Coefficient ……………………….………….……….. ±0.05%/℃
GENERAL SPECIFICATIONS:
NOTE:
Operating Ambient Temperature ..............…………………...... see derating
c
u
r
v
e
Storage
Temperature
…………………………...….......…….......
-40~100℃
Humidity …………………………...….......….. 93% RH max. Non condensing
Switching Frequency .…………...................................... 130KHz Typical
1. CBM100S Series: Add a 0.1uF ceramic capacitor and a 10uF E.L.
capacitor to output for Ripple &Noise measuring @20MHz BW.
2. Voltage accuracy is set at 60% rated load.
3. Line regulation is measured from High Line to Low Line with rated load.
4. Load regulation is measured at 60%±40% rated.
MTBF …...… MIL-HDBK-217F, GB, 25℃/115VAC ….…… 100Khrs min.
No Load Input Power Consumption…………...…...………....………..<0.5W
Altitude ……………………………………………………………………2000M
Dimensions....….4.60x2.40x0.67 Inches (116.80x61.00x17.00mm)
W eight ………………………………………..……23 6g (0. 52P o unds)
SAFETY AND EMC:
Emission and Immunity …….… EN55022 Class B, FCC Part 15 Class B
EN61000-6-3, EN61000-3-2, EN61000-3-3
EN55024, EN61000-6-1, EN61204-3
Safety ………………………………..… IEC60950-1, EN60950-1, UL60950-1
Mechanical Specification
Typical at 25℃, 230Vac and 75% rated load, unless otherwise Specified
2
5. Typical efficiency with 230Vac and full load at 25℃
6. Power dissipation (Pd): Pd =Pi-Po=Po(1-η)/η