ETC 1220A-005D-3L

Model 1220
Process Control
PC Board Mountable Pressure Sensor
Medical Instrumentation
0-50 mV Output
HVAC
Gage, Differential and Absolute
Barometric Pressure
Temperature Compensated
Air Flow Management
Avionics
DESCRIPTION
The Model 1220 is a temperature compensated, piezoresistive
silicon pressure sensor packaged in a dual-in-line configuration
and intended for cost sensitive applications where excellent
performance and long-term stability are required.
Integral temperature compensation is provided over a range
of 0-50°C using laser-trimmed resistors. An additional lasertrimmed resistor is included to normalize pressure sensitivity
variations by setting the current drive to the sensor bridge,
resulting in an interchangeability of ±1% prior to amplification.
Gage, absolute, and differential pressure ranges from 0-2
PSI to 0-100 PSI are available. Multiple lead and tube
configurations are also available for customizing the package for
specific applications.
Please refer to the low pressure section for information on
FEATURES
products with operating pressures less than 0-2 PSI. For a
Dual-in-line Package
compensated sensor using a gain set resistor as opposed to a
±0.1% Non-linearity
current set resistor, please refer to the Model 1210.
±0.5% Temperature Performance
DIMENSIONS
1.0% Interchangeable Span
(provided by current set resistor)
Solid State Reliability
Low Power
STANDARD RANGES
Range
psia
0 to 2
1-16
psid
psig
●
●
0 to 5
●
●
●
0 to 15
●
●
●
0 to 30
●
●
●
0 to 50
●
●
●
0 to 100
●
●
●
HITs – Standard
Model 1220
PC Board Mountable Pressure Sensor
PERFORMANCE SPECIFICATIONS
Supply Voltage: See application schematic
Ambient Temperature: 25°C (Unless otherwise specified)
PARAMETERS
MIN
TYP
MAX
UNITS
NOTES
Full Scale Output Span
49.5
50.0
50.5
mV
1
2
±mV
2
3
Zero Pressure Output
Pressure Non-linearity
0.05
0.1
±% Span
Pressure Hysteresis
0.01
0.1
±% Span
4400
6000
Ω
Temperature Error - Span
0.3
0.5
±% Span
2, 4
Temperature Error - Zero
0.1
0.5
±% Span
1, 2, 4
Thermal Hysteresis - Zero
0.1
Input & Output Resistance
2500
Supply Current
±% Span
2.0
mA
5
Response Time
1.0
msec
6
Output Noise
1.0
µV p-p
7
2
MΩ
8
50
MΩ
Output Load Resistance
Insulation Resistance (50 VDC)
Pressure Overload
3X
Operating Temperature
-40°C to +125°C
Storage Temperature
-50°C to +150°C
Rated
Weight
3 Grams
Media
Non-corrosive Gases Compatible with Wetted Materials
Notes
1. For 2 psi output span is 20.0 mV ± 1%, amplified span is 1.232V and TC
zero temperature error is ±1.25%.
2.
9
10
8.
Prevents increase of TC-Span due to output loading.
9.
3X or 200 psi maximum, whichever is less. 20 psi for 2 psi and 5 psi
versions.
Compensation resistors are an integral part of the sensor package; no
additional external resistors are required. Pins 7 and 8 must be kept
open.
10. Wetted materials are glass, ceramic, silicon, RTV, nickel, gold, and
aluminum.
3.
Best Fit Straight Line.
11. Soldering of lead pins: 250°C for 5 seconds maximum.
4.
Temperature range: 0-50°C in reference to 25°C.
12. Tube length: L=470 ± 5 mil, S=300 ± 3 mil, N=no tube.
5.
Guarantees input/output ratiometricity.
6.
For a zero-to-full scale pressure step change.
13. Lead pins can either be in the same or the opposite direction as the
pressure tube. See Dimensions drawing for lead configurations.
7.
10 Hz to 1 kHz.
CONNECTIONS
ORDERING INFORMATION
1220 A - 015 G - 3 S
Pressure Tubes (L, S, N - see note 12)
Lead Configuration (1, 3 - see note 13)
Type (G = Gage, A = Absolute, D = Differential)
Pressure Range
Grade
Model
APPLICATION SCHEMATIC
June 2001
HITs – Standard
Feel free to contact customer service with any questions at
Toll free 1(800)745-8008; Phone (757)766-1500; Fax (757)766-4297
1-17