Continental Device India Limited An ISO/TS 16949, ISO 9001 and ISO 14001 Certified Company TRIAC CJD137D DPAK (TO-252) Plastic Package For use Motor, Light Dimmer, Air Con, Electric Switch Applications ABSOLUTE MAXIMUM RATINGS PARAMETER Repetitive Peak Off State Voltage SYMBOL *VDRM VALUE 400 UNIT V IT (RMS) ITSM 8.0 55 A A Tj 110 ºC Storage Temperature Tstg - 40 to +125 ºC Average Gate Power PG (AV) 0.5 W PGM 5.0 W RMS on State Current Non Repetitive Peak on State Current Operating Junction Temperature Peak Gate Power ELECTRICAL CHARACTERISTICS (TJ=25ºC unless specified otherwise) PARAMETER SYMBOL TEST CONDITION IDRM VD=400V Off State Leakage Current On State Voltage Holding Current Gate Trigger Current Gate Trigger Voltage MARKING MIN MAX 100 UNIT µA VTM IT=5A, IG=35mA 1.65 V IH IGT VD=12V, IG=35mA 20 mA 35 35 35 15 35 mA mA mA mA mA 1.5 1.5 1.5 V V V VD=12V, RL=100Ω T2+ G+ T2+ GT2- G400E 400F VD=12V, RL=100Ω T2+ G+ T2+ GT2- G- VGT CDIL CJD137D XY MX CDIL CJD137DE XY MX 15 CDIL CJD137DF XY MX XY= Date Code CJD137DRev120606E Continental Device India Limited Data Sheet Page 1 of 5 CJD137D DPAK (TO-252) Plastic Package CJD137DRev120606E Continental Device India Limited Data Sheet Page 2 of 5 CJD137D DPAK (TO-252) Plastic Package CJD137DRev120606E Continental Device India Limited Data Sheet Page 3 of 5 CJD137D DPAK (TO-252) Plastic Package CJD137DRev120606E Continental Device India Limited Data Sheet Page 4 of 5 Customer Notes CJD137D DPAK (TO-252) Plastic Package Component Disposal Instructions 1. CDIL Semiconductor Devices are RoHS compliant, customers are requested to please dispose as per prevailing Environmental Legislation of their Country. 2. In Europe, please dispose as per EU Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). Disclaimer The product information and the selection guides facilitate selection of the CDIL's Semiconductor Device(s) best suited for application in your product(s) as per your requirement. It is recommended that you completely review our Data Sheet(s) so as to confirm that the Device(s) meet functionality parameters for your application. The information furnished in the Data Sheet and on the CDIL Web Site/CD are believed to be accurate and reliable. CDIL however, does not assume responsibility for inaccuracies or incomplete information. Furthermore, CDIL does not assume liability whatsoever, arising out of the application or use of any CDIL product; neither does it convey any license under its patent rights nor rights of others. These products are not designed for use in life saving/support appliances or systems. CDIL customers selling these products (either as individual Semiconductor Devices or incorporated in their end products), in any life saving/support appliances or systems or applications do so at their own risk and CDIL will not be responsible for any damages resulting from such sale(s). CDIL strives for continuous improvement and reserves the right to change the specifications of its products without prior notice. CDIL is a registered Trademark of Continental Device India Limited C-120 Naraina Industrial Area, New Delhi 110 028, India. Telephone + 91-11-2579 6150, 4141 1112 Fax + 91-11-2579 5290, 4141 1119 [email protected] www.cdilsemi.com CJD137DRev120606E Continental Device India Limited Data Sheet Page 5 of 5