ETC 12T5.15UW

8.5 Watt UW Triple Series DC/DC Converters
Features
Description
n
Wide 4:1 Input Voltage Range (9-36 or 18-72VDC)
n
Triple Low Noise, Highly Regulated Outputs
The 8.5 Watt Triple Output DC/DC converters are ideal for
wide (4:1) input range applications. These units are particularly
well suited for solar powered RTUs and instruments.
n
Efficiency 70% for All Line Conditions
n
No Derating to 80°C Case Temperature
n
Six-Sided Shielded Low Thermal
Gradient Copper Case
n
500 VDC Minimum Input to Output Isolation
n
Overvoltage Protected Outputs
n
Pulse by Pulse Digital Current Limiting
n
Five Year Warranty
They are designed with a high accuracy feedback control
circuit and coupled inductor magnetics. Each converter has
both a logic shut down pin and thermal overload protection
circuitry. All outputs and the power switch are overvoltage
protected.
These converters are encased in a six-sided, completely
shielded copper case. The UW Triple Series is covered under
the CALEX 5 Year Warranty.
Selection Chart
Model
12T5.12UW
Input Range
VDC
MIN
MAX
Outputs
VDC
Outputs
mA
9.00
36.00
5, ±12
800, ±185
800, ±150
12T5.15UW
9.00
36.00
5, ±15
48T5.12UW
18.00
72.00
5, ±12
800, ±185
48T5.15UW
18.00
72.00
5, ±15
800, ±150
8.5 Watt UW Triple Series Block Diagram
SHIELDED ISOLATION
TRANSFORMER
6 +5 OUTPUT
1000 µF
THERMAL
SHUTDOWN
100 µF
A
7 +5 CMN
3 + OUTPUT
4 ± CMN
5 - OUTPUT
100 µF
-INPUT 2
LC
INPUT
FILTER
PWM
CONTROL
FEEDBACK
AMPLIFIER
1997
1
ON/OFF 8
1.5 MEG || 0.1µF
SIX-SIDED SHIELDED COPPER CASE
2401 Stanwell Drive
Concord, CA 94520-4841
(510) 687-4411 • Fax (510) 687-3333
http://www.calex.com
1
CALEX FaxFACTS: 129
+INPUT
8.5 Watt UW Triple Series DC/DC Converters
Input Parameters*
Model
12T5.12UW
Voltage Range
Reflected Ripple, 0-20MHz bw
Input Current Full Load
No Load
Efficiency
Switching Frequency
Maximum Input Overvoltage, 100ms
No damage
Turn-on Time, 1% Output Error
MIN
MAX
TYP
MAX
TYP
TYP
TYP
12T5.15UW
48T5.12UW
9.00
36.00
48T5.15UW
18.00
72.00
VDC
30
60
908
19
908
19
MAX
mA P-P
230
15
TYP
230
15
78
%
kHz
85
TYP
mA
55
45
VDC
120
Recommended Fuse
Units
ms
(2)
Output Parameters*
Line Regulation
Vin = Min-Max VDC
Short Term Stability (4)
MIN
MAX
MIN
TYP
MAX
TYP
MAX
TYP
MAX
TYP
Long Term Stability
TYP
Transient Response (5)
Dynamic Response (6)
Input Ripple Rejection (7)
TYP
TYP
TYP
TYP
MAX
TYP
MAX
TYPO
Rated Current (3)
Voltage Range
100% Load
Load Regulation Min-Max Load
Noise, 0-20MHz bw
Temperature Coefficient
Overvoltage Clamp (8)
Short Circuit Protection to
Common for all Outputs
±12
50
185
11.76
12.00
12.24
2.0
3.0
0.5
1.0
0.02
±15
50
150
14.55
15.00
15.45
2.0
3.0
0.5
1.0
40
70
35
20
50
120
200
15.0
75
6.8
Units
VDC
mA
VDC
%
%
%
0.2
%/kHrs
50
µs
mV peak
dB
mV P-P
ppm/°C
A
18.0
VDC
Continuous, 8 Hours Minimum Current Limit and Thermal Overload
NOTES:
parameters measured at Tc=25°C, nominal input voltage
* All
and full rated load unless otherwise noted. Refer to the
CALEX Application Notes for the definition of terms,
measurement circuits and other information.
(2) Determine the correct fuse size by calculating the maximum DC
current drain at low line input, maximum load and then adding 20
to 25 percent.
(3) The module will not be damaged if run at less than minimum load.
Regulation can degrade with less than minium load or substatial
load imbalance.
(4) Short term stability is specified after a 30 minute warm-up at full
load, and with constant line, load and ambient conditions.
(5) The transient response is specified as the time required to settle
from 25 to 75% step load change (rise time of step = 2µ Sec.) to
a 1% error band.
(6) Dynamic response is the peak overshoot voltage during the
transient response time defined in note 5 above.
2401 Stanwell Drive
Concord, CA 94520-4841
(510) 687-4411 • Fax (510) 687-3333
12T5.15UW
48T5.15UW
(7)
The input ripple rejection is specified for DC to 120Hz ripple with
a modulation amplitude of 1% Vin.
(8) For module protection only, see also note 2.
(9) The logic shutdown pin is Open Collector TTL, CMOS, and relay
compatible. The input to this pin is referenced to input minus.
(10) The functional temperature range is intended to give an additional
data point for use in evaluating this power supply. At the low
functional temperature the power supply will function with no side
effects, however, sustained operation at the high functional
temperature will reduce expected operational life. The data sheet
specifications are not guaranteed over the functional temperature
range.
(11) The case thermal impedance is specified as the case temperature
rise over ambient per package watt dissipated.
http://www.calex.com
2
1997
Output Voltage
12T5.12UW
48T5.12UW
CALEX FaxFACTS: 129
Model
12T5.12UW
12T5.15UW
48T5.12UW
48T5.15UW
5
200
800
4.90
5.00
5.10
2.0
3.5
0.5
1.5
8.5 Watt UW Triple Series DC/DC Converters
General Specifications *
All Models
Logic Shutdown (9)
ON Logic Level
or Leave Pin Open
OFF Logic Level
Input Resistance
Converter Idle Current,
Shut Down Pin Low
Isolation
Isolation Voltage
10µA Leakage
Input-Output
Input to Output
Capacitance
Environmental
Case Operating Range
No Derating
Units
MIN
2.4
VDC
MAX
TYP
1.2
10
VDC
kohms
TYP
6.0
mA
MIN
500
VDC
TYP
190
pF
MIN
MAX
MIN
Case Functional Range (10)
MAX
MIN
Storage Range
MAX
Thermal Impedance (11)
TYP
Thermal Shutdown
TYP
Case Temperature
General
-25
80
-40
90
-55
100
4.4
°C/Watt
90
°C
Unit Weight
7.0
°C
°C
BOTTOM VIEW
Mechanical tolerances unless otherwise noted:
X.XX dimensions: ±0.020 inches
X.XXX dimensions: ±0.005 inches
TYP
Mounting Kit
oz
Seal around terminals is not hermetic. Do not immerse units in any
liquid.
MS9
Pin
1
2
3
4
5
6
7
8
12T5.15UW EFFICIENCY Vs. LINE INPUT
80
100% FULL LOAD
75
50% FULL LOAD
Function
+INPUT
-INPUT
+12/ +15 OUTPUT
±OUTPUT CMN [1]
-12/-15 OUTPUT
+5 OUTPUT
+5 CMN [1]
ON/OFF
[1] Note: Pins 4 & 7 are connected internally.
70
Typical Performance (Tc=25°C, Full Rated Load).
65
5
10
15
20
25
30
35
40
LINE INPUT (VOLTS)
A
CURVES APPLICABLE TO BOTH ±12 AND ±15 VDC
12T5.15UW EFFICIENCY Vs. LOAD
48T5.15UW EFFICIENCY Vs. LINE INPUT
85
85
LINE = 12VDC
100% FULL LOAD
50% FULL LOAD
75
LINE = 9VDC
75
1997
EFFICIENCY (%)
EFFICIENCY (%)
80
80
70
LINE = 36VDC
70
65
60
65
10
20
30
40
50
60
70
80
20
2401 Stanwell Drive
Concord, CA 94520-4841
(510) 687-4411 • Fax (510) 687-3333
40
60
80
100
LOAD (%)
LINE INPUT (VOLTS)
http://www.calex.com
3
CALEX FaxFACTS: 129
EFFICIENCY (%)
SIDE VIEW
°C
8.5 Watt UW Triple Series DC/DC Converters
Typical Performance (Tc=25°C, Full Rated Load).
CURVES APPLICABLE TO BOTH ±12 AND ±15 VDC
+5 VOLT OUTPUT*
CROSS REGULATION Vs. PERCENT OF FULL LOAD
48T5.15UW EFFICIENCY Vs. LOAD
EFFICIENCY (%)
80
LINE = 48VDC
75
70
LINE = 72VDC
65
60
55
20
40
60
80
1.0
0.5
0.0
+\-15 MIN LOAD
-0.5
-1.0
-1.5
20
30
40
50
60
70
80
90
12T INPUT CURRENT Vs. LINE INPUT VOLTAGE
+15 VOLT OUTPUT*
CROSS REGULATION Vs. PERCENT OF FULL LOAD
NORMALIZED OUTPUT VOLTAGE (%)
INPUT CURRENT (AMPS)
+\-15 FULL LOAD
1.5
5 VOLT LOAD (%)
1.2
1.0
0.8
100% FULL LOAD
0.6
0.4
0.2
50% FULL LOAD
0.0
10
15
20
25
30
35
+5 FULL LOAD
0.5
-15 FULL LOAD
0.0
+5 FULL LOAD
-15 MIN LOAD
-0.5
+5 MIN LOAD
-15 FULL LOAD
-1.0
+5 MIN LOAD
-15 MIN LOAD
-1.5
-2.0
30
40
50
60
70
80
90
LINE INPUT (VOLTS)
+15 VOLT LOAD (%)
48T INPUT CURRENT Vs. LINE INPUT VOLTAGE
-15 VOLT OUTPUT*
CROSS REGULATION Vs. PERCENT OF FULL LOAD
NORMALIZED OUTPUT VOLTAGE (%)
0.6
0.4
100% FULL LOAD
0.2
50% FULL LOAD
0.0
10
20
30
40
50
60
70
80
0.4
A
0.2
100
+5 FULL LOAD
+15 FULL LOAD
-0.0
-0.2
-0.4
+5 MIN LOAD
-0.6
+15 FULL LOAD
-0.8
-1.0
30
LINE INPUT (VOLTS)
2401 Stanwell Drive
Concord, CA 94520-4841
(510) 687-4411 • Fax (510) 687-3333
100
1.0
40
0.8
INPUT CURRENT (AMPS)
2.0
LOAD (%)
1.4
0
2.5
100
1.6
5
3.0
40
50
60
70
80
90
100
1997
LINE = 18VDC
-15 VOLT LOAD (%)
http://www.calex.com
4
CALEX FaxFACTS: 129
NORMALIZED OUTPUT VOLTAGE (%)
85
8.5 Watt UW Triple Series DC/DC Converters
Typical Performance (Tc=25°C, Full Rated Load).
CURVES APPLICABLE TO BOTH ±12 AND ±15 VDC
12T IDLE CURRENT Vs. LINE INPUT
48T IDLE CURRENT Vs. LINE INPUT
INPUT CURRENT (mAMPS)
11
14
12
10
8
10
9
8
7
6
6
15
20
25
30
35
40
10
20
30
LINE INPUT (VOLTS)
40
50
60
70
80
LINE INPUT (VOLTS)
OUTPUT VOLTAGE Vs. CASE TEMPERATURE
0.4
+/-15 OUTPUT
0.2
+5 OUTPUT
0.0
-0.2
-0.4
-0.6
-30
-20
-10
0
10
20
30
40
50
60
70
80
CASE TEMPERATURE (Deg C)
A
1997
10
2401 Stanwell Drive
Concord, CA 94520-4841
(510) 687-4411 • Fax (510) 687-3333
http://www.calex.com
5
CALEX FaxFACTS: 129
5
NORMALIZED OUTPUT (%)
INPUT CURRENT (mAMPS)
16