ALLEN-BRADLEY 1397-A100N-HA2-DS050-PE

1397
Digital DC Drive
Available in either regenerative or non-regenerative configurations, the
1397 family of digital DC drives employs advanced microprocessor
technology to help deliver performance, flexibility and
communications options in a complete, economical drive package.
To help achieve accurate setup, precise control and flexible operation,
all 1397 DC drives are digitally programmable. Each drive may be
programmed locally from a front mounted control panel, or from an
external Allen-Bradley PLC® or SLC®.
Contents
Description
1397 Product Selection
Factory Installed Options
User Installed Options
Conformity to Standards
2
4
5
The 1397 conforms to the following:
Conforms to:
UL Listed
CSA Certified (C-UL)
CE Approved
Allen-Bradley
Page(s)
Standard Product
✔
✔
✔
1
1397
Digital DC Drive
1397 Product Selection
The 1397 product program includes standard 1397 DC drives rated
from (1.1-448 kW) 1.5-600Hp, offered in both regenerative and nonregenerative configurations. All drives are supplied chassis mounted –
IP 00 (open) – for user installation. There is a limited offering of
factory mounted options along with a larger offering of option kits for
user installation. All standard products in this program are predefined
and not generally subject to modification. For special requirements
consult Allen-Bradley.
230V AC Input Product Selection
1397
Bulletin Number
- A001N ➊ - HA2 ➋ Rating Type
(must be specified)
Control Interface
(must be specified)
DS050
AC Line Disconnect
(optional)
-
PE
Pulse Encoder Interface
(optional)
Nominal
Drive Rating 230V AC Drives — IP 00 (Open) — No Enclosure
kW (Hp) ➌
Code
1.2 (1.5)
1.5 (2)
2.2 (3)
3.7 (5)
5.5 (7.5)
7.5 (10)
11 (15)
15 (20)
18.5 (25)
22 (30)
30 (40)
37 (50)
45 (60)
56 (75)
75 (100)
93 (125)
112 (150)
A001__➊
A002__➊
A003__➊
A005__➊
A007__➊
A010__➊
A015__➊
A020__➊
A025__➊
A030__➊
A040__➊
A050__➊
A060__➊
A075__➊
A100__➊
A125__➊
A150__➊
230V AC Rated➍ 240VDC Rated➍
Line Amps
Armature Amps
10
11
13
19
26
33
48
63
80
94
125
154
186
226
307
370
443
7
9
12
20
29
38
55
73
93
110
146
180
218
265
360
434
521
150VDC Rated➎
Field Amps
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
15
15
➊ Either an “N” (non-regenerative) or an “R” (regenerative) drive must be specified.
➋ At least one of either a Human Interface Module (HIM) or Option 1203-GD2 using DriveTools32™
will be required to program the drive. Chosen option(s) may be ordered factory installed (if
available) or as user installed kits.
➌ kW ratings are based on rated input voltage.
➍ Consult factory for alternate voltages.
➎ For special field voltage requirements refer to the Enhanced Field Supply Option.
2
Allen-Bradley
1397
Digital DC Drive
380/415V AC Product Selection
1397
Bulletin Number
- U55FN ➊ - HA2 ➋ Rating Type
(must be specified)
Control Interface
(must be specified)
DS050
-
AC Line Disconnect
(optional)
PE
Pulse Encoder Interface
(optional)
380/415V AC Drives — IP 00 (Open) — No Enclosure
380V AC Input 415V AC Input
kW (Hp)
kW (Hp)
Code
1.8 (2.4)
9 (12)
17.9 (24)
35.8 (48)
89.5 (120)
2.1(2.8)
10.3(13.8)
20.8(27.6)
41.2(55.2)
102.9(138)
U7F__➊
U29F__➊
U55F__➊
U110F__➊
U265F__➊
380/415V AC
400/460V DC Rated 250/270V DC Rated
Rated Line Amps Armature Amps
Field Amps
10
10
10
15
20
7
29
55
110
265
10
26
48
94
226
460V AC Product Selection
1397
Bulletin Number
- B003N ➊ - HA2 ➋ Rating Type
(must be specified)
Control Interface
(must be specified)
DS050
AC Line Disconnect
(optional)
-
PE
Pulse Encoder Interface
(optional)
Nominal
Drive Rating 460V AC Drives — IP 00 (Open) — No Enclosure
kW (Hp) ➌
Code
2.2 (3)
3.7 (5)
5.5 (7.5)
7.5 (10)
11 (15)
15 (20)
18.5 (25)
22 (30)
30 (40)
37 (50)
45 (60)
56 (75)
75 (100)
93 (125)
112 (150)
149 (200)
187 (250)
224 (300)
298 (400)
373 (500)
448 (600)
B003__➊
B005__➊
B007__➊
B010__➊
B015__➊
B020__➊
B025__➊
B030__➊
B040__➊
B050__➊
B060__➊
B075__➊
B100__➊
B125__➊
B150__➊
B200__➊
B250__➊
B300__➊
B400__➊➏
B500__➊➏
B600__➊➏
460V AC Rated➍ 500VDC Rated➍
Line Amps
Armature Amps
10
12
15
18
24
31
39
45
63
74
86
110
143
177
213
281
351
421
567
680
816
6
10
14
19
27
35
45
52
73
86
100
129
167
207
250
330
412
495
667
800
960
300VDC Rated➎
Field Amps
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
15
15
15
15
15
➊ Either an “N” (non-regenerative) or an “R” (regenerative) drive must be specified.
➋ At least one of either a Human Interface Module (HIM) or Option 1203-GD2 using DriveTools32™
will be required to program the drive. Chosen option(s) may be ordered factory installed (if
available) or as user installed kits.
➌ kW ratings are based on rated input voltage.
➍ Consult factory for alternate voltages.
➎ For special field voltage requirements refer to the Enhanced Field Supply Option.
➏ Inverting fault protection must be separately supplied external to drive on 400-600 Hp negative.
See user installed option 1397-IFB600.
Allen-Bradley
3
1397
Digital DC Drive
Factory Installed Options
Control Options ➊
Description
Used With . . .
AC Line Disconnect
230V Rating ➋
kW
(Hp)
(1.5-25)
1.2-18.5
(30)
22
(40-60)
30-45
(75)
56
(100)
75
(125-150)
92-112
All Drives
460V Rating ➋
kW
(Hp)
(3-50)
2.3-37
(60)
45
(75-125)
56-93
(150)
112
(200)
149
(250-300)
187-224
(400-500)
298-373
(600)
448
Blower Motor Starter - Current Rated
Blower Motor Amp Current Rating
0.4-0.63
0.63-1.0
1.0-1.4
1.4-1.8
1.7-2.4
2.2-3.1
2.8-4.0
3.5-5.0
4.5-6.5
6.0-8.5
7.5-11.0
Pulse Encoder Interface
AC Tachometer Interface
Fixed Field Supply
Enhanced Field Supply - Current Rated
- Provides field preweakening for gear-in.
- Provides 2 240V DC field on 230V AC rated drives
for textile and MG set replacement applications.
- Provides a means to match many different field
voltages without requiring a transformer
DC Amp Current Rating
10
20
Option Code
-DS050
-DS060
-DS125
-DS150
-DS200
-DS300
-DS500
-DS600
All Drives
-MB006
-MB010
-MB014
-MB018
-MB024
-MB031
-MB040
-MB050
-MB065
-MB085
-MB110
All Drives
-PE
All Non-Regen Drives -AC
All Drives
➌➍
All Drives
➌
All Drives
Regulated Field Supply - Current Rated
Provides field weakening and field current regulation
DC Amp Current Rating
4
10
15
I/O Expansions Card
All Drives
Provides additional I/O structure
(5) Digital Outputs
(2) Digital Outputs
(2) Analog Inputs
(2) Analog Outputs
(1) Frequency Input
Frequency Output
-FS3010
-FS3020
➌
-FS2004
-FS2010
-FS2015
-L11
➊ All options are chassis mounted unless noted. For a more functionally complete description of
each option, refer to publication 1397-BR001.
➋ kW ratings are based on rated input voltage.
➌ Fixed Field Supply is provided with:
230V AC drives rated 56 kW (75 Hp) and below
380V AC drives rated 35.8 kW (48 Hp) and below
415V AC drives rated 41.2 kW (55.2 Hp) and below
460V AC drives rated 112 kW (150 Hp) and below.
Regulated Field Supply is provided with:
230V AC drives rated 75 kW (100 Hp) and above
380V AC drives rated 89.5 kW (120 Hp)
415V AC drives rated 102.9 kW (138 Hp)
460V AC drives rated 149 kW (200 Hp) and above.
➍ Fixed Field Supply does not have field economy. Check motor requirements for applicability.
4
Allen-Bradley
1397
Digital DC Drive
HIM Options
User Installed Options
Description
Used With . .
IP 20 (NEMA/UL Type 1) HIM
Blank - No Functionality
Programmer Only
Programmer/Controller w/Analog Pot
Programmer/Controller w/Digital Pot
All Drives
Option Code
-HAB
-HAP
-HA1
-HA2
Inverting Fault Breaker Kit
Description
Used With. . .
Provides inverting fault protection for 400-600 Hp regen- 400-600 Hp
erative drives. Trip setting adjustable for 400, 500, or 600 regenerative
drives.
Hp Drives. Mounts separately from the Drive Chassis.
Catalog Number
1397-IFB600
240V DC Dynamic Brakes, IP00 (No Enclosure) ➊
Drive Output
kW (Hp) ➋
1.2 (1.5)
1.5 2)
2.2 (3)
3.7 (5)
5.5 (7.5)
7.5 (10)
11 (15)
15 (20)
18.5 (25)
22 (30)
30 (40)
37-45 (50-60)
56 (75)
75 (100)
93 (125)
112 (150)
Used With. . .
Catalog Number
All 230VAC
Input Drives
1397-DB-A001L
1397-DB-A002L
1397-DB-A003L
1397-DB-A005L
1397-DB-A007L
1397-DB-A010L
1397-DB-A015L
1397-DB-A020L
1397-DB-A025L
1397-DB-A030L
1397-DB-A040L
1397-DB-A060L
1397-DB-A075L
1397-DB-A100L
1397-DB-A125L
1397-DB-A150L
500V DC Dynamic Brakes, IP00 (No Enclosure) ➊
Drive Output
kW (Hp) ➋
2.2 (3)
3.7 (5)
5.5 (7.5)
7.5 (10)
11 (15)
15-18.5 (20-25)
22 (30)
30 (40)
37-45 (50-60)
56 (75)
75-93 (100-125)
112 (150)
149 (200)
187 (250)
224 (300)
298 (400)
373 (500)
448 (600)
Used With. . .
Catalog Number
All 460V AC
Input Drives
1397-DB-B003L
1397-DB-B005L
1397-DB-B007L
1397-DB-B010L
1397-DB-B015L
1397-DB-B025L
1397-DB-B030L
1397-DB-B040L
1397-DB-B060L
1397-DB-B075L
1397-DB-B125L
1397-DB-B150L
1397-DB-B200L
1397-DB-B250L
1397-DB-B300L
1397-DB-B400L
1397-DB-B500L
1397-DB-B600L
➊ Dynamic brake hardware (DC loop contactor, control transformer & grids) mounts separately from
the drive chassis. For a more functionally complete description of each option refer to publication
1397-BR001. Dynamic Brake Kits 1397-DB-B400L, -B500L, and -B600L use the Drive contactor.
➋ kW ratings are based on rated input voltage.
Allen-Bradley
5
1397
Digital DC Drive
Line Reactors, IP00 (Open Style) – 230V, 60Hz
Input or Output Line Reactor
Drive
Catalog
Number
Drive Output
3% Impedance
5% Impedance
kW
Hp
Catalog Number
Catalog Number
A001
A002
A003
A005
A007
A010
A015
A020
A025
A030
A040
A050
A060
A075
A100
A125
A150
1.2
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
56
75
93
112
1.5
2
3
5
7.5
10
15
20
25
30
40
50
60
75
100
125
150
1321-3R8-A
1321-3R8-A
1321-3R12-A
1321-3R18-A
1321-3R25-A
1321-3R35-A
1321-3R45-A
1321-3R55-A
1321-3R80-A
1321-3R100-A
1321-3R130-A
1321-3R160-A
1321-3R160-A
1321-3R200-A
1321-3RB250-A
1321-3RB320-A
1321-3RB400-A
1321-3R8-B
1321-3R8-B
1321-3R12-B
1321-3R18-B
1321-3R25-B
1321-3R35-B
1321-3R45-B
1321-3R55-B
1321-3R80-B
1321-3R100-B
1321-3R130-B
1321-3R160-B
1321-3R160-B
1321-3R200-B
1321-3RB250-B
1321-3RB320-B
1321-3RB400-B
Line Reactors, IP00 (Open Style) – 460V, 60Hz
6
Input or Output Line Reactor
Drive
Catalog
Number
Drive Output
3% Impedance
5% Impedance
kW
Hp
Catalog Number
Catalog Number
B003
B005
B007
B010
B015
B020
B025
B030
B040
B050
B060
B070
B100
B125
B150
B200
B250
B300
B400
B500
B600
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
56
75
93
112
149
187
224
298
373
448
3
5
7.5
10
15
20
25
30
40
50
60
75
100
125
150
200
250
300
400
500
600
1321-3R8-C
1321-3R8-B
1321-3R12-B
1321-3R18-B
1321-3R25-B
1321-3R35-B
1321-3R35-B
1321-3R45-B
1321-3R55-B
1321-3R80-B
1321-3R80-B
1321-3R100-B
1321-3R130-B
1321-3R160-B
1321-3R200-B
1321-3RB250-B
1321-3RB320-B
1321-3RB400-B
1321-3R500-B
1321-3R600-B
1321-3R750-B
1321-3R8-D
1321-3R8-C
1321-3R12-C
1321-3R18-C
1321-3R25-C
1321-3R35-C
1321-3R45-C
1321-3R55-C
1321-3R80-C
1321-3R80-C
1321-3R100-C
1321-3R130-C
1321-3R160-C
1321-3R160-C
1321-3R200-C
1321-3RB250-C
1321-3RB320-C
1321-3RB400-C
1321-3R500-C
1321-3R600-C
1321-3R750-C
Allen-Bradley
1397
Digital DC Drive
Line Reactors, IP00 (Open Style) – 380V, 50Hz
Input or Output Line Reactor
Drive
Catalog
Number
Drive Output
3% Impedance
5% Impedance
kW
Hp
Catalog Number
Catalog Number
U7F
U29F
U55F
U110F
U265F
1.8
9
17.9
35.8
89.5
2.4
12
24
48
120
1321-3R8-C
1321-3R25-B
1321-3R45-B
1321-3R80-A
1321-3R200-B
1321-3R8-D
1321-3R25-C
1321-3R45-C
1321-3R80-B
1321-3R200-C
Line Reactors, IP00 (Open Style) – 415V, 50Hz
Allen-Bradley
Input or Output Line Reactor
Drive
Catalog
Number
Drive Output
3% Impedance
5% Impedance
kW
Hp
Catalog Number
Catalog Number
U7F
U29F
U55F
U110F
U265F
2.1
10.3
20.8
41.2
102.9
2.8
13.8
27.6
55.2
138
1321-3R8-C
1321-3R25-B
1321-3R45-B
1321-3R80-A
1321-3R200-B
1321-3R8-D
1321-3R25-C
1321-3R45-C
1321-3R80-B
1321-3R200-C
7
1397
Digital DC Drive
Isolation Transformers, Three-Phase – IP32, NEMA/UL Type 3R
1397 Drive
Output➋
Transformer
kW (Hp)
kVA
Output Rating Primary Voltage Secondary Voltage
1.2-2.2 (1.5-3) 5
3.7 (5)
7.5
5.5 (7.5)
11
7.5 (10)
14
11 (15)
20
15 (20)
27
18.5 (25)
34
22 (30)
40
30 (40)
51
37 (50)
63
45 (60)
75
56 (75)
93
75 (100)
118
93 (125)
145
112 (150)
175
149 (200)
220
187 (250)
275
224 (300)
330
298 (400)
440
373 (500)
550
448 (600)
660
Volts
230V AC
Catalog Number
460V AC
Catalog Number
230
460
230
460
230
460
230
460
230
460
230
460
230
460
230
460
230
460
230
460
230
460
230
460
230
460
230
460
230
460
230
460
230
460
230
460
230
460
230
460
230
460
1321-3TW005-AA
1321-3TW005-BA
1321-3TW007-AA
1321-3TW007-BA
1321-3TW011-AA
1321-3TW011-BA
1321-3TW014-AA
1321-3TW014-BA
1321-3TW020-AA
1321-3TW020-BA
1321-3TW027-AA
1321-3TW027-BA
1321-3TW034-AA
1321-3TW034-BA
1321-3TW040-AA
1321-3TW040-BA
1321-3TW051-AA
1321-3TW051-BA
1321-3TH063-AA
1321-3TH063-BA
1321-3TH075-AA
1321-3TH075-AB
1321-3TH093-AA
1321-3TH093-BA
1321-3TH118-AA
1321-3TH118-BA
1321-3TH145-AA
1321-3TH145-BA
1321-3TH175-AA
1321-3TH175-BA
1321-3TH220-AA
1321-3TH220-BA
1321-3TH275-AA
1321-3TH275-BA
1321-3TH330-AA
1321-3TH330-BA
—
—
—
—
—
—
—
—
1321-3TW007-AB
1321-3TW007-BB
1321-3TW011-AB
1321-3TW011-BB
1321-3TW014-AB
1321-3TW014-BB
1321-3TW020-AB
1321-3TW020-BB
1321-3TW027-AB
1321-3TW027-BB
1321-3TW034-AB
1321-3TW034-BB
1321-3TW040-AB
1321-3TW040-BB
1321-3TW051-AB
1321-3TW051-BB
1321-3TH063-AB
1321-3TH063-BB
1321-3TH075-AB
1321-3TH075-BB
1321-3TH093-AB
1321-3TH093-BB
1321-3TH118-AB
1321-3TH118-BB
1321-3TH145-AB
1321-3TH145-BB
1321-3TH175-AB
1321-3TH175-BB
1321-3TH220-AB
1321-3TH220-BB
1321-3TH275-AB
1321-3TH275-BB
1321-3TH330-AB
1321-3TH330-BB
1321-3TH440-AB
1321-3TH440-BB
1321-3TH550-AB
1321-3TH550-BB
1321-3TH660-AB
1321-3TH660-BB
➊ Note the discount schedule difference between Bulletin 1321 and 1397 products.
➋ kW ratings are based on rated input voltage.
8
Allen-Bradley
1397
Digital DC Drive
Communication Option Kits ➍
Option Cable 1202-C03/C10/C30/C90
to Drive
to PLC
RIO
Comm
Status
Input Voltage
DIN Rail
120/240V AC
Input
Communication Module
GD1/GD2 – Typical Configuration
Catalog Number
(Loose Kit)
Description
Used with . . .
Remote Mounted (DIN Rail) – 115V AC
Requires 115V AC power supply
Single Point Remote I/O
RS232/422/485, DF1 and DH485 Protocol
All Drive Ratings
Remote Mounted (DIN Rail) – 24V DC
Requires 24V DC power supply
Single Point Remote I/O
RS232/422/485, DF1 and DH485 Protocol
DeviceNet™
Enhanced DeviceNet™
All Drive Ratings
ControlNet™ to SCANport Adapter➊➋
Remote Mounted (DIN Rail)
Requires 24VDC power supply
All Drive Ratings
1203-CN1➊➋
EtherNet/IP to SCANport Adapter➊➋
Remote Mounted (DIN Rail), 24V DC
Requires 24VDC power supply
AC to DC Power Receptacle
All Drive Ratings
1203-EN1➊➋
Serial Flash Cable
Connects CN1, GU6 and SSS to a
computer RS-232 port for adapter
programming and for DriveTools32 &
DriveExplorer™ serial interface.
All Drive Ratings
1203-SFC
SLC™ Communication Module
(SLC 500 to SCANport Module)
Provides a connection for up to 3 drive
products.
All Drive Ratings
1203-SM1➊
Smart Self-powered Serial Converter
Includes 1203-SFC and 1202-C10 Cables
Serial Null Modem Adapter
All Drive Ratings
1203-SSS
1203-GD1➊
1203-GD2➊
1203-GK1➊
1203-GK2➊
1203-GK5➊
1203-GU6➊➋
SLC
ESC
SEL
JOG
SM1 – Typical Configuration
ESC
SEL
ESC
JOG
SEL
JOG
CN1 – Typical Configuration
20-XCOMM-AC-PS1
1203-SNM
All Drives
Universal Serial Bus™ (USB) Converter
Includes 2m USB, 20-HIM-H10 & 22-HIM-H10
Cables
Communication Option Cable Kit
0.33 Meters (1.1 Feet)
1 Meter (3.3 Feet)
3 Meter (9.8 Feet)
9 Meter (29.5 Feet)
All Communication
Options Listed
SCANport Expander Module
One to Two
One to Four
One to Two Port Splitter Cable
All Drive Ratings
1203-USB
1202-C03
1202-C10
1202-C30
1202-C90
1203-SG2
1203-SG4
1203-S03
➊ Requires a Communication Option Cable (1202-C03/C10/C30/C90) to be functional. These units are not acceptable for NEMA/UL Type 4 door mounting or UL
Type 4X outdoor duty.
➋ Adapter is programmed/configured via RS-232 using the 1203-SFC cable, (purchased separately) and using a compatible network specific software tool.
➌ Discount Schedule C2.
➍ Options mount separately from the drive chassis. For a more functionally complete description of each option, refer to publication 1397-BR001.
Allen-Bradley
9
1397
Digital DC Drive
Human Interface Module (HIM) Options
HIM
HIM
Cradle
Option Cable
1202-H03/H10/H30/H90
HIM
Communication
Port
Option Cable
1202-C03/C10/C30/C90
Description
Used With. . .
Human Interface Modules
IP 20 (NEMA/UL Type 1)
Blank — No Functionality
Programmer Only
Programmer/Controller w/Analog Pot
Programmer/Controller w/Digital Pot
Human Interface Modules
IP 66 (NEMA/UL Type 12/UL Type 4X Indoor)
Programmer Only
Programmer/Controller w/ Digital Pot
Option Cable Kit - Connect to HIM Cradle
Port
0.33 Meters (1.1 Feet)
1 Meter (3.3 Feet)
3 Meter (9.8 Feet)
9 Meter (29.5 Feet)
Option Cable Kit - Connect to Comm Port
0.33 Meters (1.1 Feet)
1 Meter (3.3 Feet)
3 Meter (9.8 Feet)
9 Meter (29.5 Feet)
IP 20 (NEMA/UL Type 1) Door Mounted
Bezel Kit
All Drives
Catalog Number
1201-HAB ➊
1201-HAP ➊
1201-HA1 ➊
1201-HA2 ➊
IP 66 (NEMA/UL Type 12/UL
Type 4X Indoor) Enclosures
1201-HJP ➊
1201-HJ2 ➊
HIMs not mounted in the HIM
cradle but connected to the
HIM Cradle Port
1202-H03
1202-H10
1202-H30
1202-H90
HIMs not mounted in the HIM
cradle but connected to the 1202-C03
HIM Comm Port
1202-C10
1202-C30
1202-C90
User Supplied IP 20 (NEMA/ 1201-DMA
UL Type 1) Enclosures and
HIM
➊ If this option is mounted separately or used as a hand-held device, an Option Cable Kit is required.
10
Allen-Bradley
1397
Digital DC Drive
Accessories & Spare Parts
Allen-Bradley
Description
Catalog Number
Blower Motor/Starter, 0.4-0.63A
Blower Motor/Starter, 0.63-1.0A
Blower Motor/Starter, 1.0-1.4A
Blower Motor/Starter, 1.4-1.8A
Blower Motor/Starter, 1.7-2.4A
Blower Motor/Starter, 2.2-3.1A
Blower Motor/Starter, 2.8-4.0A
Blower Motor/Starter, 3.5-5.0A
Blower Motor/Starter, 4.5-6.5A
Blower Motor/Starter, 6.0-8.5A
Blower Motor/Starter, 7.5-11.0A
Pulse Encoder Interface
AC Tach Interface Module
Enhanced Field Supply for 230/460V & 10A
Enhanced Field Supply for 230/460V & 20A
Regulated Field Supply, 4A
Regulated Field Supply, 10A
Regulated Field Supply, 15A
Control Interface, 115V AC
I/O Expansion Card
1397-FC0300V Fuse Conv., 3-60 Hp @ 460V to 1.5-30 Hp @ 230V
460V TO 230V Fuse Conv.,75-150 Hp @ 460 to 40-75 Hp @ 230
Line Disconnect, 1.5-25 Hp @ 230V, 3-50 Hp @ 460V
Line Disconnect, 30 Hp @ 230V, 60 Hp @ 460V
Line Disconnect, 30-60 Hp @ 230V,75-125 Hp @ 460V
Line Disconnect, 75 Hp @ 230V, 150 Hp @ 460
Disconnect Switch, 200 Hp, 460V AC
Disconnect Switch, 250-300 Hp,460V AC
Disconnect Switch, 500 Hp @ 460V AC
Disconnect Switch, 600 HP @ 460V AC
1397-MB006
1397-MB010
1397-MB014
1397-MB018
1397-MB024
1397-MB031
1397-MB040
1397-MB050
1397-MB065
1397-MB085
1397-MB110
1397-PE
1397-AC
1397-FS3010
1397-FS3020
1397-FS2004
1397-FS2010
1397-FS2015
1397-L10
1397-L11
1397-FC030
1397-FC075
1397-DS050
1397-DS060
1397-DS125
1397-DS150
1397-DS200
1397-DS300
1397-DS500
1397-DS600
11