CUI CT-1205H

Date: 9/21/2006
Part No: CT-1205H
Unit: mm
Description: magnetic buzzer
Page No: 1 of 5
Specifications
Rated voltage
5.0 Vo-p
Operating voltage
Mean current
3.0 ~ 7.0 Vo-p
60 mA max.
Coil resistance
Sound output
47.0 ±7.0 Ω
Min. 88 (Typical 92) dBA
Rated frequency
Operating tempurature
Storage tempurature
Dimensions
Weight
Material
Terminal
RoHS
2,400 Hz
-30 ~ +70° C
-40 ~ +85° C
ø12.8 x W12.8 x H10 mm
2.0 g
PPS (S-206)
SMD type (Sn Plating)
yes
Applying rated voltage, 2400 Hz
square wave, ½ duty
Distance at 10cm (A-weight free air).
Applying rated voltage of 2400 Hz, square
wave, ½ duty.
See attached drawing
See attached drawing
Frequency Response Curve
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Part No: CT-1205H
Date: 9/21/2006
Unit: mm
Description: magnetic buzzer
Page No: 2 of 5
Appearance Drawing
Tolerance: ±0.5
Measurement Method
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Date: 9/21/2006
Part No: CT-1205H
Unit: mm
Description: magnetic buzzer
Page No: 3 of 5
Mechanical Characteristics
Item
Solderability
Soldering Heat Resistance
Terminal Mechanical Strength
Vibration
Drop Test
Test Condition
Lead terminals are immersed in solder bath
of +270 ±5°C for 3 ±1 seconds.
The product follows the reflow temperature
curve to test its reflow thermo stability.
Lead pads shall be soldered onto the pc
board and the force of 9.8 N (1.0 kg) shall
be applied behind the part for 10 seconds.
The buzzer will be measured after applying
a vibration amplitude of 1.5 mm with 10 to
55 Hz band of vibration frequency to each of
the 3 perpendicular directions for 2 hours.
The part is to be dropped from a height of
75 cm onto a 40 mm thick wooden board 3
times in 3 axis (X, Y, Z) for a total of 9 drops.
Evaluation Standard
95% surface of lead pads must
be covered with fresh solder.
No in interference in operation.
Test Condition
The part will be subjected to +85°C for
96 hours.
The part will be subjected to -40°C for
96 hours
The part will be subjected to 10 cycles. One
cycle will consist of:
Evaluation Standard
No damage or cutting off.
After the test, the part shall meet
specifications without any
damage to the appearance and
the SPL should be within ±10
dBA of the initial SPL.
Environment Test
Item
High temp. test
Low temp. test
Thermal shock
Temp./Humidity cycle
Phone: 800.275.4899
The part shall be subjected to 10 cycles. One
cycle will last for 24 hours and consist of:
Fax: 503.612.2381
www.cui.com
After the test, the part shall meet
specifications without any
damage to the appearance or
performance. After 4 hours at
25°C, the SPL should be within
±10 dBA of the initial SPL.
20050 SW 112th Ave.
Tualatin, OR 97062
Date: 9/21/2006
Part No: CT-1205H
Unit: mm
Description: magnetic buzzer
Page No: 4 of 5
Mechanical Characteristics
Item
Operating (Life Test)
Evaluation Standard
Test Condition
1. Continuous life test:
The part will be subjected to 72 hours at +55°C After the test, the part shall meet
specifications without any
with 5 V, 2400 Hz applied.
damage to the appearance. After
4 hours at +25°C, the SPL
2. Intermittent life test:
should be within ±10 dBA of the
A duty cycle of 1 minute on, 1 minute off, a
initial SPL.
minimum of 10,000 times at room temp
(+25±10°C) with 5 V, 2400 Hz applied.
Test Conditions
Standard Test Condition
Judgement Test Condition
a) Tempurature: +5 ~ +35°C
a) Tempurature: +25±2°C
b) Humidity: 45 - 85%
b) Humidity: 60 - 70%
c) Pressure: 860 - 1060 mbar
c) Pressure: 860 - 1060 mbar
Recommended Temperature Profile for Reflow Oven
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Part No: CT-1205H
Date: 9/21/2006
Unit: mm
Description: magnetic buzzer
Page No: 5 of 5
Recommended Land Pattern
Packaging
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062