ETC 154N-100G-R

Model 154N UltraStable
Medical Instruments
316 SS Pressure Sensor
Process Control
0-100 mV Output
Waste Water Management
Gage, Sealed Gage and Absolute
Refrigeration/Compressors
Temperature Compensated
Pressure Transmitters
Level Systems
DESCRIPTION
The Model 154N is a media compatible, compensated,
piezoresistive silicon pressure sensor packaged in a 316 stainless
steel housing. The sensing package utilizes silicone oil to
transfer pressure from the 316 stainless steel diaphragm to the
sensing element.
The Model 154N is designed for low pressure applications.
A ceramic substrate is attached to the package that contains
laser-trimmed resistors for temperature compensation and offset
correction. An additional laser-trimmed resistor is included
which can be used to adjust sensitivity variations by setting the
gain of an external differential amplifier to within ±1%
interchangeability.
Alternatives include cap-ring Models 84 or 86, ¼ NPT
Model 96, and Model 85. High pressure sensors are also
FEATURES
available.
O-ring Mount
0.1% Pressure Non-linearity
–20°c To +85°c Compensated
Temperature Range
DIMENSIONS
w/BACK END OPTIONS
BASIC SENSING ELEMENT
DIAPHRAGM,
.001 [0.03] THICK
Ø.7413/.7427
[18.829/18.864]
WELD RING
1.0% Interchangeable Span
(Provided By Gain Set Resistor)
Solid State Reliability
Low Power
O-RING, BUNA-N,
Ø.070 [1.78]
.54
.24 [6.0]
EPOXY STRAIN RELIEF
STANDARD RANGES
Range
0 to 5
psig
psia
RIBBON CABLE, 26 AWG
-O
●
●
0 to 30
●
●
0 to 50
●
●
0 to 100
●
●
0 to 300
●
●
0 to 500
●
●
-E
BALL SEAL
Contact Factory
0 to 15
4X Ø.018 [0.46]
6.00±.25
[152.4±6.4]
CONNECTOR, FEMALE,
MOLEX P/N 14-56-2066
(.100 [2.54] CENTERS)
2X .18 [4.6]
PAD #1
+E
+O
Ø.745/.747
[18.92/18.97]
2X .09 [2.3]
3X .05 [1.3]
VIEW SHOWN w/o CABLE
AND CONNECTOR FOR CLARITY
1-60
ISO – Standard
Model 154N UltraStable
316 SS Pressure Sensor
PERFORMANCE SPECIFICATIONS
All parameters measured at 1.5mA drive and at 25°C after 10 second warm up, unless otherwise specified. Unless specifically indicated, only those parameters
indicated as tested are verified on each part. Parameters are specified for the compensated version only.
PARAMETERS
MIN
TYP
MAX
UNITS
NOTES
Full Scale Output Span
75
100
150
mV
1, 2
Zero Offset
-1
0
1
mV
2
0.10
% Span
3
Pressure Non-linearity
-0.10
Pressure Hysteresis
-0.05
0.02
0.05
% Span
Input Resistance
2,000
3,500
4,500
Ω
Output Resistance
4000
25000
Ω
Temperature Error - Span
-0.75
0.75
% Span
4
Temperature Error - Zero
-0.5
0.5
% Span
4, 5
Thermal Hysteresis - Span
0.05
% Span
4
Thermal Hysteresis - Zero
0.05
% Span
4
0.1
±% Span/yr.
Long Term Stability - Offset
Long Term Stability - Span
0.1
Supply Current
0.5
Output Load Resistance
Insulation Resistance (50 VDC)
1.5
±% Span/yr.
mA
6
5
MΩ
7
50
MΩ
8
Pressure Overload
2.0
3X
Rated
Compensated Operating Temperature
–20°C to +85°C
9
Operating Temperature Range
–40°C to +125°C
9
Storage Temperature Range
–50°C to +125°C
9
Media - Pressure Port
Liquids and Gases compatible with 316L Stainless Steel
Media - Reference Port
Compatible with Silicon, Pyrex, Gold, Fluorosilicone Rubber and
316L Stainless Steel
Weight
24 g
10
Notes
1. For amplified output circuits, 3.012V ± 1% interchangeability with gain
set resistor. See Application Note TN-003.
7.
8.
Between case and sensing element.
2.
Measured at vacuum for absolute (A), ambient for gage (G).
9.
3.
Best fit straight line.
Maximum temperature range for product with standard cable and
connector is –20°C to +105°C.
Load resistance to reduce measurement errors due to output loading.
4.
Over Temperature range: -20°C to +85°C Span with respect to +25°C.
10. Weight depends upon configuration (cable, connector).
5.
15 psi range sensors have a temperature error of ±0.75% (Max) of
Zero from -20°C to 85°C.
11. Standard gauge units are not recommended for vacuum applications.
For vacuum applications, contact factory.
6.
Guarantees output/input ratiometricity.
12. For pressure ranges < 15 psi, consult factory on performance
specifications.
ORDERING INFORMATION
APPLICATION SCHEMATIC
154N
(Note 11)
(Note 12)
CONNECTIONS
PAD NO. / CABLE
FUNCTION
1
+OUT
ISO – Standard
2
-EX
3
+EX
4
-OUT
5
GAIN
6
GAIN
June 2001
Feel free to contact customer service with any questions at
Toll free 1(800)745-8008; Phone (757)766-1500; Fax (757)766-4297
1-61